You are on page 1of 11

LOUVERS

WE SHAPE

AIR

PRODUCT BULLETIN PRODUCTS CATALOGUE

Dubai Head Office: Tel: +971 4 706 9777 Fax: +971 4 706 9787 Abu Dhabi Branch: Tel: +971 2 645 0107 Fax: +971 2 645 0167 Email: betai@betag.com P.O.Box 50708, Dubai United Arab Emirates

www.betag.com

index

>> >> >> >> >> >> >> >>

GRAVITY AIR LOUVERS EXHAUST AIR LOUVERS FRESH AIR LOUVERS - HINGED FRESH AIR LOUVERS SAND TRAP LOUVERS ROUND EXHAUST LOUVER - IMP KLIMA PERFORMANCE CHART (STL & GAL) PERFORMANCE CHART (EAL & FAL)

1 2 3 4 5 6 7 8

LOUVERS
GRAVITY AIR LOUVERS
45 mm
Extruded Aluminum Profile 1.2 mm thk

45 mm

71

B+10mm

B+50mm

B+10mm

71

>> The gravity air louver is a wall mounted device. It is composed of a set of horizontally mounted blades; they are
normally closed and are free to rotate about the horizontal axis.

>> The blades & frame are manufactured from aluminum extruded profiles.
Foam Gasket (optional)

TYPE OF FIXING
NON RETURN DAMPER
SCREW FIXING
CLIP FIXING

GRAVITY AIR LOUVERS (DUCTED)


100
ALUMINIUM FRAME 1.8 MM THK

CONNECTING ROD (OPTIONAL)

AIR FLOW
DUCT SIZE

Extruded Aliminium profile 1.2 MM Thk

ORDERING SYSTEM
RAL: POWDER COATED FINISH AS PER RAL CODES

FINISH

SIZE:

WIDTH

HEIGHT

MAX SIZE: 2000 MM

2000 MM

SIZE

GAL:

GRAVITY AIR LOUVER

GAL - CR: GRAVITY AIR LOUVER WITH CONNECTING ROD NRD: NON RETURN DAMPER

TYPE EXAMPLE : GAL 1000 + 150 RAL 9O16

NRD-CR NON RETURN DAMPER WITH CONNECTING ROD

01

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

B+50mm

71

71

LOUVERS EXHAUST AIR LOUVERS TYPE OF FIXING

Type of Fixing: Screw fixing

(B) - 10 mm

(B) - 50 mm

Clip fixing

The exhaust air louver is a weather proof external cover for air inlet and discharge openings, suitable for most external walling and screening applications.

>>

EXHAUST AIR LOUVER

>> The exhaust air louver is composed of a set of blades made of heavy gauge aluminium extrusions arranged in
horizontal rows and inclind downward to protect against rain water.
>> The exhaust air louver is used in cooling, heating and air ventilation applications.

45 mm

ORDERING SYSTEM

FINISH
RAL:
POWDER COATED FINISH AS PER RAL CODES

SIZE

TYPE

Anodized: ANDOIZED ALUMINUM FINISH

SIZE:

WIDTH

HEIGHT

MAX SIZE: 2000 MM

2000 MM

EAL: EXHAUST AIR LOUVER EAL / IS: EXHAUST AIR LOUVER WITH INSECT SCREEN

+ 150 Anodized EXAMPLE : EAL 1000

02

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

LOUVERS
FRESH AIR LOUVERS - HINGED

TYPE OF FIXING

screw fixing

(B) - 10 mm

(B) - 50 mm

>> The fresh air louver is composed of an exhaust air louver which is fixed to a frame that contains a filter by means of steel hinges. >> The filter is made of washable aluminium media. It is attached to the back of the louver and is easily removable. >> The fresh air louver can be opened like an ordinary door to give flexibility to

Clip Fixing

FRESH AIR LOUVER

acesss the filter for either cleaning or changing


>> The fresh air louver is used in cooling, heating and ventilation application. The

45 mm

existence of filter provides the entrance of clean air to the system.

ORDERING SYSTEM

FINISH

SIZE

TYPE

RAL:

POWDER COATED FINISH AS PER RAL CODES

Anodized: ANDOIZED ALUMINUM FINISH

SIZE:

WIDTH

HEIGHT

MAX SIZE: 2000 MM

2000 MM

FALH: FALHD:

HINGED FRESH AIR LOUVER HINGED FRESH AIR LOUVER WITH DAMPER

EXAMPLE : FALH 1000+ 150 Anodized

03

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

LOUVERS
FRESH AIR LOUVERS

TYPE OF FIXING

Screw

(B) - 10 mm

(B) + 50 mm

TYPE OF FIXING
Clip

>> The fresh air louver is a simple form

of filter louver. It is composed of an exhaust louver with an aluminium filter fixed at the back.
>> The fresh air louver is used to supply

fresh clean air to the handling units.


>> The filter is made from washable aluminium media and is fixed on the back of the grille. >> Insulating gasket is fixed around the

45 mm

back of the frame to prevent infiltration between the frame and the wall.
Available types of finishing:
>> Natural andozied aluminium finish. >> Powder coated to RAL codes.

ORDERING SYSTEM

FINISH

SIZE

TYPE

RAL:

POWDER COATED FINISH AS PER RAL CODES

Anodized: ANDOIZED ALUMINUM FINISH

SIZE:

WIDTH

HEIGHT

MAX SIZE: 2000 MM

2000 MM

FAL: FALD:

FRESH AIR LOUVER FRESH AIR LOUVER WITH DAMPER

+ 150 Anodized EXAMPLE : FAL 1000

04

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

LOUVERS SAND TRAP LOUVERS TYPES


SAND TRAP LOUVER 76
20

SAND TRAP LOUVER WITH SAND CHUTE

25 25
28

20

28

>> The sand trap louver is made of

HEIGHT

aliuminium section. It is composed of two sets of inverted U-channels, mounted vertically on two opposite rows.
>> The sand trap louver is used at the

fresh air inlet duct of the air handling units. It can lower the dust loading of conventional filtration as it is designed to separate large size sand particles at low to medium speeds. It is also fitted with a bird screen mesh made of galvanized steel to protect against the unwanted objects.
25
50

Sand Chute

>> The sand trap louver is a self empty-

HOLE

ing system. It has a set of holes at the bottom face of the casing to discharge separated sand particles.
>> Can be supplied (as an option ) with :
28 50

28

28

120

HEI HEIGHT GHT

25

28
WIDTH (STL)

1 - VCD 2 - Wiremesh 3 - Sliding filter

WIDTH (STL-C) SAND TRAP LOUVERS BOTTOM VIEW DETAILS

ORDERING SYSTEM
76 25

Handle of sand filter Sand filter 20mm thk freely sliding upward

RAL:

POWDER COATED FINISH AS PER RAL CODES

FINISH

SIZE

TYPE

20

Anodized: ANDOIZED ALUMINUM FINISH

28 28

SIZE:

MAX SIZE: 2000 MM

HEIGHT

WIDTH

HEIGHT 2000 MM

Handle riveted to frame Frame of sand filter

STL SF/IS: SAND TRAP LOUVER STLC SF/IS: SAND TRAP LOUVER WITH SAND CHUTE OPTIONS SF : WITH SLIDING FILTER IS : WITH INSECT SCREEN

View detail from arrow A

Filter

05

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

25

7 76 6

LOUVERS
ROUND EXHAUST LOUVERS

Application :
Type OZR - 1 circular protection Grilles are used in all kinds of low pressure air conditioning, air heating and ventelation, where round supply and exhasut air opening require protection against outside influence (rain, birds, insects etc....).

Description :
Type OZR CIRCULAR PROTECTION Grillers are constructed of round Frame, horizontal blades and protective grille. They are made of galvanised sheet metal or aluminium and could be finished with any RAL paint according to the customers request.
Installation on the round tube via the flange.

Standard sizes and installation:


6

D3

D2

D1

D3

D2

D1 D1 D

Installation on the round hole in the sheet.

sizes 400 500 630 800 900 1000

D 400 500 630 800 900 1000

D1
390 490 620 790 890 990

D2
419 519 649 819 919 1029

D3
450 550 680 850 950 1070

B
25 25 25 25 50 50

H
37 37 37 37 65 65

Chart of total air pressure drop: Ordering key: OZR / S / RAL / size 500
size 400, 500, 630, 800, 900, 1000 requested RAL S - zincked sheet A - Al. Sheet

Ordering Specification: OZR size 400 RAL 9016 Pieces 3


terminal velocity v (m/s)

vel. A (m 2 )

400 0.10

500 0.17

630 0.27

800 0.44

900 0.56

1000 0.69

From the chart, the total air pressure drop ( Pcel) in respect to terminal velocity (v) on free sectional area (A) is calculated. The right for technical modification reserved.

06

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

D3

D2

LOUVERS PERFORMANCE CHART

SAND TRAP LOUVERS


0.0 100

Face Velocity, FPM


200 300 400 500 600 200 180 80 160 140 60 120 100 40 80 60 20 40 20

>> Test results conducted on similar equipment indicated a typical efficiency of 90% an AC coarse (150 - 700 mIcrons). and 60% on AC fine test ducts (75 - 700) microns) >> Free area ratio = 0.32 ( approx.) >> To calculate the air flow rate :

100

CFM= 0.32

A (in) B(in) Face velocity(fpm) 144 Face velocity (m/s)

L/S = 0.32 A (mm) B (mm) 1000

>> For normal operation conditions, sand trap louvers used for natural ventilation purpose are rated at a recommended Fac velocity of 1-2m/s

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0

Face velocity, m/s

GRAVITY AIR LOUVERS


PRESSURE DROP

CFM= 0.82

A (in) B(in) Face velocity(fpm) 144 B (mm) Face velocity (m/s) 1000

L/S = 0.82 A (mm)

0 0.0

10 0.04

20

30 0.12

>> To calculate the air flow rate :

40 0.16

>> Free area ratio (approx.) = 0.82 for 100% open blades.

50 0.20

Pa inch w.g.

0 0

1.0 200

2.0 400

3.0 600

4.0 800

5.0 1000

m/s fpm

FACE VELOCITY BASED ON WIDTH (A)

HEIGHT (B)

07 07

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Pressure Drop, Pa

Efficiency %

LOUVERS PERFORMANCE CHART

EXHAUST AIR LOUVERS


PRESSURE DROP

>> Free area ratio ( approx.) = 0.42 >> To calculate the air flow rate :

CFM= 0.42

A (in) B(in) Face velocity(fpm) 144 Face velocity (m/s)

L/S = 0.42 A (mm) B (mm) 1000

0 0.0

0 20 2 0.08

40 0.16

60 0.24

80 0.32

100 0.40

Pa inch w.g.

0 0

1.0 200

2.0 400

3 .0 3.0 6 00 600

m/s fpm

FACE VELOCITY BASED ON WIDTH (A)

HEIGHT (B)

FRESH AIR / FILTER LOUVERS


PRESSURE DROP

>> Free area ratio ( approx.) = 0.37 >> To calculate the air flow rate :

L/S = 0.37 A (mm) B (mm) 1000

Face velocity (m/s)

0 0.0

20 0.08

40 0.16

CFM= 0.37

A (in) B(in) Face velocity(fpm) 144

60 0.24 0.24

80 0.32

100 0.40 0.4 0

Pa inch w.g.

0 0

1.0 200

2.0 400

3.0 600

m/s fpm

FACE VELOCITY BASED ON WIDTH (A)

HEIGHT (B)

08

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE