Professional Documents
Culture Documents
2008
Architects Assistant
A simple, online plug and play program, Architects Assistant will generate customized CSI specifications and CAD drawings. This will help you design and build the elevator that meets building specification and code requirements.
CONTENTS
SELECTION PROCESS
HYDRAULIC ELEVATORS
The Architects Assistant does the restquickly and accurately. Find the Architects Assistant online at Otis.com. Its the only tool youll ever need to design and build elevators to meet todays needs.
Hydraulic Systems Separate machine room required at bottom landing Machine room can be located remotely or adjacent to hoistway at bottom landing Gen2 Machine-Roomless System Requires separate control space/room Flexible control space/room placementup to 250 feet away from top of hoistway (depending on wiring configuration within the building)
Required dimensions will be found on specific product pages in this guide. Consult your Otis representative for specific requirements.
400 and above 300 200 100 60 30 Travel height 20 0 Otis Hydraulic Elevators Otis Traction Elevators
Holeless Telescopic Holeless Roped Holeless Holed
Selection Process
Holeless Hydraulic
Travel Height Maximum Maximum stops Speed (ft/min)
E
20 ft 3 100, 125
PLAN
B
D G
Hoisting Beam (Not by Otis)
Key Attributes No need for well hole drilling and its associated costs Above-ground solution substantially reduces risk of soil and ground water contamination Applicable for: Hazard-sensitive sites Waterfront sites Existing buildings Available in both passenger and service elevator configurations and capacities Solid-state starter improves performance through precise control of electric current Optional: Front and rear entrances Ceiling height of 9-7 8-0 clear opening Glassback REM remote elevator monitoring
K
SECTION
Dimensions
Passenger elevators
Service elevators
Rated lbs. Passenger Capacity 1 Car 2 A Interior width B Interior depth C Interior height D Car door width Hoistway E Width Width in seismic zones 3 F Depth 4 G Rough opening width H Rough opening height I Clear opening height J Clear overhead to hoist beam @ 100 ft/min @ 125 ft/min K Minimum pit depth 5 Machine Room L Number of elevators in group Width x depth
1 Capacity 2 Interior 3 In
Hydraulic Elevators
3000 20/18
3500 23/21
5000 AIA 33/31 5-8 9-0 4-0 7-7 7-7 10-9 5-8
6-8 6-8 4-9 5-5 8-0 (Optional 9-7 ) 3-6 3-6 8-4 8-6 6-3 5-2 8-4 8-6 6-11 5-2
7-10 7-0 (Optional 8-0 ) 12-4 12-7 12-4 12-4 12-4 12-4 12-7 12-7 12-7 12-7 4-0 (5-0 for Canadian Province of Ontario) 1 5-9 x 7-4 2 11-6 x 8-6
5 Pit
12-4 12-7
12-5 12-8
12-4 12-7
3 17-0 x 8-6
4 22-0 x 8-6
depth changes based on speed: For 100 fpm, pit depth increases 1 in depth for each 1 increase in rise over 13-7 up to 20-0. For 125 fpm, pit depth increases 1 in depth for each 1 increase in rise over 12-8 up to 20-0.
4 For
cars with front and rear doors, add 9 14 to depth for 2000 to 3500 lb. capacities; add 12 14 for 4500 and 5000 lb. capacities.
44 ft 1 in 5 100, 125
PLAN
B
D G
Hoisting Beam (Not by Otis)
Key Attributes No need for well hole drilling and its associated costs Above-ground solution substantially reduces risk of soil and ground water contamination Applicable for: Hazard-sensitive sites Waterfront sites Existing buildings Available in passenger elevator configurations and capacities only Solid-state starter improves performance through precise control of electric current Optional: Front and rear entrances Ceiling height of 9-7 8-0 clear opening Glassback REM remote elevator monitoring
K
SECTION
Dimensions
Passenger elevators
Rated lbs. 2000 2100 2500 3000 3500 Passenger Capacity1 13/12 13/12 16/15 20/18 23/21 Car 2 A Interior width 5-8 5-8 6-8 6-8 6-8 B Interior depth 4-3 4-3 4-3 4-9 5-5 C Interior height 8-0 (Optional 9-7 ) D Car door width 3-0 3-0 3-6 3-6 3-6 Hoistway 3 E Width (rise up to 30 ft 1 in) 7-4 7-4 8-4 8-4 8-4 Width (rise up to 30 ft 1 in) in seismic zones 4 7-6 7-6 8-6 8-6 8-6 Width (rise over 30 ft 1 in) 7-10 7-10 8-10 8-10 8-10 5-9 5-9 5-9 6-3 6-11 F Depth 5 4-8 4-8 5-2 5-2 5-2 G Rough opening width 7-10 H Rough opening height 7-0 (Optional 8-0 ) I Clear opening height J Clear overhead to hoist beam(rise up to 30 ft 1 in) 12-8 @ 100 ft/min 12-11 @ 125 ft/min Clear overhead to hoist beam (rise over 30 ft 1 in) 13-0 @ 100 ft/min 13-2 @ 125 ft/min 4-0 (5-0 for Canadian Province of Ontario) to 7-6 depending on rise K Minimum pit depth6 Machine Room L Number of elevators in group 1 2 3 4 Width x depth 5-9 x 7-4 11-6 x 8-6 17-0 x 8-6 22-0 x 8-6
1 Capacity 2 Interior 3
code requirements: US/Canada. dimensions may vary depending on interior finishes. A 3-stage plunger may require additional hoistway width. Contact your local Otis representative for all hoistway dimension changes.
4 In
seismic zones 2 or greater. A 3-stage plunger may require extra hoistway width. Please consult your local Otis representative. 5 For cars with front and rear doors add 9 14 to depth. 6 Maximum rise with 4-0 pit depth is 34-4. Consult Otis.com or your local Otis representative.
Hydraulic Elevators
E A
Key Attributes No need for well hole drilling and its associated costs Above-ground solution substantially reduces risk of soil and ground water contamination Applicable for: Hazard-sensitive sites Waterfront sites Existing buildings Available in passenger elevator configurations and capacities only Solid-state starter improves performance through precise control of electric current Optional: Front and rear entrances Ceiling height of 9-7 8-0 clear opening Glassback REM remote elevator monitoring
D G
Hoisting Beam (Not by Otis)
K
SECTION
Dimensions
Passenger elevators
Rated lbs. 2000 Passenger Capacity1 13/12 Car 2 5-8 A Interior width 4-3 B Interior depth C Interior height 3-0 D Car door width Hoistway 8-0 E Width 3 Width in seismic zones 8-0 4 5-9 F Depth 4-8 G Rough opening width H Rough opening height I Clear opening height J Clear overhead to hoist beam @ 100 ft/min @ 125 ft/min @ 150 ft/min K Minimum pit depth Machine Room 1 L Number of elevators in group Width x depth 5-9 x 7-4
1 Capacity 2 Interior
Hydraulic Elevators
2100 13/12
2500 16/15
5-8 6-8 4-3 4-3 8-0 (Optional 9-7 ) 3-0 3-6 8-0 8-0 5-9 4-8 7-10 7-0 (Optional 8-0 ) 12-0 12-3 12-3 4-0 (5-0 for Canadian Province of Ontario) 2 11-6 x 8-6
3 In 4 For
3 17-0 x 8-6
seismic zones 2 or greater. cars with front and rear doors, add 9 14 to depth.
4 22-0 x 8-6
Holed Hydraulic
Travel Height Maximum Maximum stops Speed (ft/min)
E
B
D G
Hoisting Beam (Not by Otis)
Key Attributes Well hole drilling required PVC protection surrounds wall and bottom of in-ground cylinder to prevent contact with underground contaminants Solid-state starter improves performance through precise control of electric current Available in both passenger and service elevator configurations and capacities Optional: Front and rear entrances Ceiling height of 9-7 8-0 clear opening Glassback REM remote elevator monitoring
K
Well Hole (Required) Cylinder with PVC Protection
SECTION
Dimensions
Passenger elevators
Service elevators
Rated lbs. Passenger Capacity1 Car 2 A Interior width B Interior depth C Interior height D Car door width Hoistway E Width Width in seismic zones3 F Depth 4 G Rough opening width H Rough opening height I Clear opening height J Clear overhead to hoist beam @ 100 ft/min @ 125 ft/min @ 150 ft/min K Minimum pit depth Machine Room L Number of elevators in group Width x depth
1 Capacity 2 Interior
6-8 6-8 5-8 4-9 5-5 7-11 8-0 (Optional 9-7 ) 3-6 3-6 4-0 8-4 8-6 6-3 5-2 8-4 8-6 6-11 5-2 7-5 7-7 9-8 5-8
7-10 7-0 (Optional 8-0 ) 12-0 12-3 12-3 12-0 12-3 12-3 12-0 12-0 12-0 12-0 12-3 12-3 12-3 12-3 12-3 12-3 12-3 12-3 4-0 (5-0 for Canadian Province of Ontario) 2 11-6 x 8-6
3 4 For
1 5-9 x 7-4
3 17-0 x 8-6
4 22-0 x 8-6
In seismic zones 2 or greater. cars with front and rear doors, add 9 14 to depth for 2000 to 3500 lb. capacities; add 12 14 for 4500 and 5000 lb. capacities.
Hydraulic Elevators
2000 13/12
2100 13/12
2500 16/15
3000 20/18
3500 23/21
4500 30/28
5000 33/31
Machine-Roomless Elevator
Travel Height Maximum 196 ft @ 200 (ft/min) 300 ft @ 350 (ft/min) 300 ft @ 400 (ft/min) 30 200, 350, 400 Key Attributes Space-saving configuration eliminates the need for a machine room Flexible control space/room placementup to 250 feet away from top of hoistway (depending on wiring configuration within the building) Environmentally-friendly system uses up to 75% less energy than traditional geared systems. Technologically advanced design makes it lubrication-free Regenerative drive delivers substantial energy savings by converting normally wasted energy into electricity and feeding it back into the building's power grid Integrated component design makes the Gen2 system the smoothest, quietest elevator in the industry Machine room version of Gen2 available at speeds up to 500 ft/min Optional: Ceiling height 9-7 Available with CompassTM 1 Glassback Destination Entry System Interior cab design flexibility REM remote elevator monitoring
Service elevators
IMPORTANT: To assist in your planning, we recommend that you call your Otis representative at the beginning of the project.
Dimensions
Passenger elevators Front 0H AIA Opening Rated lbs. 2100 2 2500 3 Passenger Capacity 13/12 16/15 Car 4 5-8 6-8516 A Interior width 4-3 4-318 B Interior depth 5 C Interior height 3-0 3-6 D Car door width Hoistway Width Single hoistway 6 7-4 8-4 E In seismic zones 6 7-4 8-6 15-0 17-0 F Double hoistway 6 In seismic zones 6 15-0 17-4 6 22-8 25-8 G Triple hoistway In seismic zones 6 22-8 26-2 6-712 6-712 H Depth In seismic zones 6-712 6-712 Rough opening width 4-8 5-2 I Rough opening height J 7 K Clear opening height L Total overhead for 8-0 car @ 200 ft/min 14-7 14-9316 1 @ 350 ft/min 15-3 2 15-5916 @ 400 ft/min 16-0 Total overhead for 9-7 car @ 200 ft/min 16-4316 @ 350 ft/min 17-0916 @ 400 ft/min 17-7 M Minimum pit depth @ 200 ft/min @ 350 ft/min @ 400 ft/min 5-8 Control Space/Room N Control spacesimplex Control roomsimplex Control roomduplex
1 2
3500 23/21
4000 27/25
7-10 7-0 (Optional 8-0 ) 14-9316 15-5916 16-0 16-4316 17-0916 17-7 14-9316 15-5916 16-0 16-4316 17-0916 17-7 14-9316 15-5916 16-0 16-4316 17-0916 17-7 14-9316 15-5916 16-4316 17-0916 14-9316 15-5916 16-4316 17-0916 14-9316 15-5916 16-4316 17-0916 14-9316 15-5916 16-4316 17-0916
For glassback dimensions visit Otis.com or contact your Otis representative. Maximum travel for 2100 lb. car is 196 ft. @ 200 fpm and 164 ft. @ 350 fpm. 3 Capacity code requirements: US/Canada. 4 Interior dimensions may vary depending on interior finishes.
The 9-7 car interior height does not apply to the 2100 lb. duty. For elevators with occupied space below, this dimension may change. Consult your Otis representative for dimensions. 7 The 8-0 height does not apply to the 2100 lb. duty. Visit www.otis.com for the latest information
G F E C B
PLAN
D I A
Buffer
SECTION
Dimensions Front 0H AIA and Rear Opening Rated lbs. Passenger Capacity 1 Car 2 A Interior width B Interior depth C Interior height D Car door width Hoistway E Width Single hoistway 3 In seismic zones 3 F Double hoistway 3 In seismic zones 3 G Triple hoistway 3 In seismic zones 3 H Depth In seismic zones I Rough opening width J Rough opening height K Clear opening height L Total overhead for 8-0 car @ 200 ft/min @ 350 ft/min @ 400 ft/min Total overhead for 9-7 car @ 200 ft/min @ 350 ft/min @ 400 ft/min M Minimum pit depth @ 200 ft/min @ 350 ft/min @ 400 ft/min Control Space/Room N Control spacesimplex Control roomsimplex Control roomduplex
1 2
Passenger elevators
Service elevators
10-4 10-6 21-0 21-4 31-8 32-2 7-818 7-818 5-8 7-10 7-0 (Optional 8-0 )
16-0
16-0
14-9316 15-5916 16-0 16-0 16-4316 17-0916 17-7 17-7 4-1114 5-514 5-8 5-8
H x 2-10 width H x 5-0 width H x 7-0 width
17-7
17-7
5-8
5-8
Capacity code requirements: US/Canada. Interior dimensions may vary depending on interior finishes. 3 For elevators with occupied space below, this dimension may change. Consult your Otis representative for dimensions.
2500 16/15
3000 20/18
3500 23/21
4000 27/25
4000H 27/25
4500H 30/28
5000H 33/31
Freight Elevators
Applications All classes of commercial and industrial: Class A general freight loading Class C industrial forklift loading Key Attributes Withstands heavier loads to meet the highest performance and quality standards in the industry Available in various duties and speeds Consult your Otis representative or Otis.com
Moving Walks
Maximum travel 263 ft (NCT Model) 394 ft (NPT Model)
RETURN END DRIVE END
Key Attributes Maximum safety, reliability and efficiency Wide range of finishes, pallet widths and optional features Commercial applications including shopping centers, casinos, airports
D E
ELEVATION
D E
G C
Dimensions
NCT Model
A Pallet width B Finish width C Maximum length D Minimum pit depth (at ends)
60640 32 4-7 263-0 3-558 1-71116 17-858 19-414 4-1018 32-9 34 61048 40 5-5 394-0 3-1178 1-4/2-034 20-312 20-312 5-818 22-1112 / 32-934
60648 40 5-3 263-0 3-558 1-71116 17-858 17-858 5-618 32-934 61056 48 6-1 394-0 3-1178 1-4/2-234 20-312 20-312 6-418 21-4 / 32-934 61064 56 6-9 394-0 3-1178 1-4 / 2-434 20-312 20-312 7-018 19-814/32-934
Minimum pit depth (at middle)1 E Minimum pit opening (return) Minimum pit opening (drive) F Minimum rough opening G Maximum length between two intermediate supports1
1
10
Escalators
Maximum rise 21 ft 4 in (NCE model) 1
LOWER LANDING UPPER LANDING
Key Attributes Quiet and smooth operation ensured by hypoid helical gear drive, which produces lower noise levels [maximum 55 dB(A)] and uses less energy than conventional wormgear machines Tapered handrail entry box helps hide the handrail's return into the guard area for added safety Wide range of decking finishes available including powder coated sheet steel, stainless steel and several anodized aluminum options
Workpoint
Edge of lower support
Finished Floor
Workpoint
C G
Dimensions
NCE Model A Step width B Finish width C Minimum pit opening D Minimum rough opening
E Maximum rise2
ELEVATION
Higher rises available (NPE model). Contact your Otis representative for dimensions. Dimensions listed assume 2 flat steps and escalator is installed under non-seismic conditions.
11
United States
Alabama Birmingham Mobile Alaska Anchorage Arizona Phoenix Arkansas Fayetteville Little Rock California Anaheim North Highlands Pasadena San Diego San Francisco Sunnyvale Colorado Denver Connecticut East Hartford Shelton Delaware Wilmington (Moorestown, NJ) Florida Ft. Lauderdale / W. Palm Beach (954) Jacksonville (904) Miami Lakes (305) Orlando (407) Pensacola (850) Sarasota (941) Tampa (813) Georgia Atlanta Savannah Hawaii Honolulu Illinois Chicago Lombard Peoria Springfield Indiana Evansville Indianapolis Iowa Urbandale Kansas Kansas City Wichita Kentucky Louisville Louisiana Metairie Shreveport Maine Westbrook Maryland Landover Linthicum (Baltimore) Massachusetts Needham Springfield Worcester Michigan Farmington Hills Grand Rapids Minnesota Roseville Mississippi Metairie (LA) Missouri Kansas City St. Louis Nebraska Omaha Nevada Las Vegas Reno New Jersey Fairfield Moorestown New Mexico Albuquerque New York Albany Buffalo East Syracuse New York Plainview Yonkers North Carolina Charlotte Raleigh North Dakota Fargo (701) 232-3385 (704) 519-0100 (919) 781-1555 (518) (716) (315) (917) (516) (914) 426-4006 686-5370 463-6615 339-9600 349-9225 375-7800 (505) 345-8189 (973) 575-8670 (856) 235-5200 (702) 740-4777 (775) 322-5411 (402) 733-2910 (913) 621-8800 (314) 533-7070 (504) 846-2300 (651) 697-7800 (248) 473-4530 (616) 975-3022 (781) 433-8600 (413) 733-5115 (508) 757-4597 (301) 324-4140 (410) 636-5700 (207) 856-2737 (504) 846-2300 (318) 636-7422 (502) 491-3636 (913) 621-8800 (316) 682-6886 (515) 270-2066 (812) 471-9770 (317) 347-2015 (312) (630) (309) (217) 454-1616 889-2800 693-8131 544-4633 (808) 599-1111 (404) 355-1991 (912) 201-0461 485-6501 296-6847 816-5740 438-3633 473-1244 342-4900 251-1841 (856) 235-5200 (860) 289-7600 (203) 944-0160 (303) 298-9300 (714) (916) (626) (858) (415) (408) 758-9593 344-2080 396-6260 560-5881 546-0880 328-0330 (479) 521-5750 (501) 312-7600 (602) 431-1181 (907) 278-4575 (205) 982-8000 (251) 433-0034
Ohio Cincinnati Cleveland Columbus Oklahoma Oregon Portland Pennsylvania Allentown Harrisburg Philadelphia (Moorestown, NJ) Pittsburgh Rhode Island Smithfield South Carolina Greenville Myrtle Beach North Charleston West Columbia Tennessee Chattanooga Knoxville Memphis Nashville Texas Dallas El Paso Fort Worth Houston San Antonio/Austin Utah Salt Lake City Vermont Burlington Virginia North VA (Landover, MD) Richmond Roanoke Virginia Beach Washington Seattle Spokane Washington D.C. D.C. ( Landover, MD) West Virginia Charleston Wisconsin Kaukauna Madison Milwaukee (920) 766-2900 (608) 249-3322 (262) 240-3400 (304) 965-2780 (301) 324-4140 (206) 243-8100 (509) 483-7328 (301) (804) (540) (757) 324-4140 213-0975 983-4640 456-0801 (802) 863-3675 (801) 486-9295 (214) (915) (817) (713) (210) 741-6207 775-0847 284-6434 524-8486 490-4960 (423) (865) (901) (615) 899-6633 525-0282 527-0291 254-3496 (864) (843) (843) (803) 675-9400 448-4471 529-9502 739-8013 (401) 232-7282 (610) (717) (856) (412) 266-8970 238-7248 235-5200 281-9292 (503) 639-7045 Oklahoma City Tulsa (513) 531-7888 (216) 573-2333 (614) 777-6500 (405) 947-1401 (918) 584-3678
Bahamas
Nassau (242) 393-1885
Canada
Alberta Calgary Edmonton British Columbia Vancouver Manitoba Winnipeg New Brunswick St. John Newfoundland St. John's Northwest Territories Nunavut Ottawa Nova Scotia Dartmouth Ontario Hamilton Mississauga Ottawa Prince Edward Island Dartmouth Quebec Montreal Ste-Foy Saskatchewan Regina Saskatoon (306) 790-7039 (306) 664-2939 (514) 489-9781 (418) 687-4848 (902) 481-8200 (905) 587-6277 (905) 276-5577 (613) 737-7670 (902) 481-8200 (709) 576-4110 (613) 737-7670 (613) 737-7709 (506) 634-1393 (204) 783-0464 (604) 412-3400 (403) 244-1040 (780) 444-2900
Guam
Tamuning (671) 647-6847
Puerto Rico
San Juan (787) 765-4969
w w w. o t i s . c o m
On the cover: 7 World Trade Center Photograph by David Sundberg/ESTO, courtesy of Silverstein Properties GEN-1127 (0208) Otis Elevator Company 2008 All rights reserved
Office Locations