You are on page 1of 108

VENTILATION FAN CATALOGUE

Proven, Reliable Bathroom Ventilation Solutions

Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans.
MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens.

PROVEN: Trusted Locally, Proven Globally. RELIABLE: Durable Ball Bearing Motors witha 5 Year Warranty. SOLUTIONS: A Complete Range of Fans, Ducting and Accessories.

Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia
Unit 2, 22 Hammond Rd Cockburn Central WA 6164

South Australia
86A Richmond Rd Keswick SA 5035

Victoria
2/13-15 Brough St Springvale VIC 3171

Queensland
26 Turbo Drive Cooparoo QLD 4151

Tasmania
Electrical Agencies 4 Linear Court Moonah TAS 7009

Newcastle
Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322

National Support Centre


Phone: 1300 666 595 Fax: 1300 666 594 Email: austsales@tnb.com Web: www.manrose.com.au

Manrose continues to lead the way as the ventilation solution providers


Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans.
Thomas and Betts have been supplying the electrical wholesale market for over 35 years and credit their success to outstanding delivery and customer service capabilities and are proud of their strong, long-standing partnerships. They represent the highest quality and most innovative products available. The MANROSE brand is known for proven, reliable solutions with an evolving product range to meet the demands of the market. Thomas & Betts and MANROSE have a strong relationship, which has seen ventilation products developed specifically for the Australian market with features demanded by the customer. This has led to all Manrose products being upgraded with ball bearing motors and a 5 year warranty. Within the Manrose range you can choose from a Classic model which offers trusted performance or a Pro-Series model with higher specifications, installation advantages and features to the contractor, as well as sought after aesthetics demanded by the consumer. A recent addition to the range is Vent-Axia Lo-Carbon range that offer ventilation fans with up to 70% energy savings. The Manrose product development team is consistently developing high quality products with features demanded by the market. Our policy of ongoing investment in product development has been a key force in driving the company to the forefront of the ventilation market. Manrose has an extraction fan for every application. Continual development and innovation ensures that future market demands are not only met but exceeded!

Lo-Carbon
PUB0385 Iss03 04/13

contents
Ventilation Selection/Regulations Selection Chart Ventilation Fans Wall/Ceiling Fans Thru Wall Fan Kits Window Mounted Fans Heat/Fan/Light Kits In-Line Fan Kits Wall Mounted Fans Thru-Roof Mounted Fans Hand Dryers Specialised Fans Fan Accessories Duct and Fittings Duct Standards Ducting Installation & Usage Aluduct/Comflex Flexible Ducting 3-9 10 12-63 12-21 22-25 26-29 30-31 32-53 54-55 56-57 58-59 60-61 62-63 64-79 64 65-71 72 Ceiling Diffuser Designer Ceiling Diffuser Flat Ceiling Diffuser Ceiling Diffuser Eggcrate Round Diffuser Ceiling Diffuser Cowls/Plate Grilles Designer Weatherproof Cowls Weatherproof Cowls Designer Weatherproof Dome Wall/Ceiling Plate Grilles Wall/Ceiling Plate Grilles Door Grille Duct Kits Roof Cowls Rangehood Ducting Kits Dryer Ducting Kit Pro Series Extension Kit 84-86 84 84 85 85 86 87-94 87 87 88 89 89 89 90-93 90-91 92 93 93

Unilok 73 PVC 74 Semiduct Semi Rigid Low Profile Ducting In-Line Branch Take Off Duct Joiners/Spigots Wall/Ceiling Grilles Designer Wall Grilles Wall Grilles Wall/Ceiling Grilles Designer Wall/Ceiling Grilles Wall/Ceiling Grilles 74 75-78 78 79 79 80-83 81 81 82 83 83

Accessories 94 Heat Trans Alpha-Numeric Index Vent-Axia Lo Carbon Range 95-97 98-100 101-104

Reducers 79

Technical Information
Technical information such as dimensions and size charts can be found beneath or on the page following the product page.

Product category index


The product category index is an alphanumeric listing of general product groups in the Thomas & Betts portfolio, this can be found on page 98.

VENTILATION SELECTION
Why you need Ventilation?
New building materials and construction methods are effectively resulting in waterproof buildings. They trap moisture inside just as effectively as they keep moisture out. Open doors and windows provide air circulation and ventilation but security considerations mean that we are increasingly less likely to use this option. As a result houses tend to remain closed up more often. Poor ventilation results in a buildup of moisture generated by cooking/bathing/showering/clothes washing- drying/LPG gas heating...even breathing! Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack of ventilation around the house as well as a damp atmosphere.

Problems Caused by Poor Ventilation


All these problems cause an avoidable level of discomfort as well as the risk of respiratory illness and general poor health. Problems also occur when steam from the kitchen or bathroom finds cooler surfaces around the house on which to condense. Warm, moisture-laden air condenses on cold surfaces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see. Moisture you cannot see is still present in the atmosphere and will be absorbed into fabrics, wall linings, bedding, etc. Attempts to conserve heat by sealing windows and therefore reducing natural ventilation makes this problem even worse. Condensation can cause considerable problems from peeling wallpaper and mould growth to severe long term structural damage to building materials.

Moisture Generators:

BATHROOM SHOWERING

CONDENSATION GAS HEATING

KITCHEN TOILET LAUNDRY

BREATHING WATERING PLANTS

Stale air out

Correct Ventilation

Ventilate Outside = Healthy Home

Incorrect Ventilation

Trapped moist air Inside the home = Unhealthy

In dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly into the roof space is not permitted under the Building Code.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

VENTILATION SELECTION
Your Ventilation Solutions

Damp air out

It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house.

Fresh air in
It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. DO NOT use ceiling fans which discharge into the ceiling cavity, this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems. In particular with bathrooms think in terms of room-conditioning. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.

Fan Placement
Careful location of an extraction fan will ensure maximum air-flow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regularperiods. Switching the fan on before starting showering or cooking sets up effective air-flows before condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air. Use a door vent if necessary. For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room. E.g. air in = air out. An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille to allow replacement air into the room.

Poor Circulation

Medium Circulation

Best Circulation

VENTILATION SELECTION
Fan Regulations What the law states
Australian Building Code Paragraph 3.8.5.0 states: Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. Mechanical ventilation for acceptable indoor air quality, except that any contaminated air from a sanitary compartment or bathroom must:

a. b. i. ii.

Exhaust directly to outside the building by way of ducts; or Exhaust into the roof space provided: It is adequately ventilated by open eaves, and/or roof vents; or The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles.

As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents. The Manrose range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural Ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room.

AS1668 (summarised): ...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...

BCA Compliance to AS/NZ 1530 Part 3 Requirements are: Internal Surface: AS/NZS 1530 Part 3 This is the Australian standard 1530, method for fire tests on building materials components and structures. Simultaneous determination of ignitability, flame propagation, heat release and smoke release Spread of flame not >0 Smoke Developed not >3 External Surface: Spread of flame not >7 Smoke developed not >5

Bathrooms
The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed.

Kitchens
The regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed.

Toilets
The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed.

Laundries
The regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

VENTILATION SELECTION
Calculating Fan Performance Litres/Second (l/s)
Milk 1 Litre

Working out the right fan for the job


Calculate the room volume in metres (l x W x H). Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit. The result is the total performance required in cubic metres per hour.

Cubic Metres/Hour (m/hr)

1m

1m

1m

To convert from one to other types ofmeasurement:


If you know Litres/Second (l/s): l/s x 3.6 = m3/hr (e.g. 25 l/s x 3.6 = 90m/hr). If you know Cubic Metres/Hour (m/hr): m3/hr 3.6 = l/s (e.g. 200m/hr 3.6 = 55.55 l/s). Note: 1m3 = 1000 Litres ACH

Select a fan with a higher performance than this figure. For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m?

Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3. 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr. The fan to choose for this bathroom would be a fan that performs at greater than 282m3/hr. A fan that has a performance level of 313m3/hr or higher (e.g. XP150, or SF150) would do thisjob.

AIR CHANGES PER HOUR (ACH)


The number of times the total room volume of air is changed each hour. Refer to the table below for the recommended Air Changes per hour based on the room type. Application Description Bathrooms Kitchens - (domestic) Laundries - (no drier) Laundries - (with drier) Toilets Bedroom Offices Cafs Canteens Garages Kitchens - (commercial) Restaurants Factories Stores & Warehouses Libraries Classroom
6

Air Changes Per Hour 11 - 15 15 - 20 6 - 10 10 - 30 6 - 10 2-5 6 - 10 10 - 12 8 - 12 6-8 20 - 30 8 - 12 8 - 10 3-6 3-5 5-7

Quick Cross-Reference Calculations:


Known l/s m/hr cfm cfm
400 350 300 250 200 50 150 100 40 30 20 50 0 10 m3/hr l/s 110 100 90 80 70 140 60 120 100 80 60 40 20 cfm

To Find m/hr l/s m/hr l/s


240 220 200 180 160

Action l/s x 3.6 =m/hr m/hr 3.6 = l/s cfm x 1.69 =m/hr cfm x 0.47 = l/s m/hr to l/s to cfm Comparison Chart

VENTILATION SELECTION
What Affects Performance? Simple facts:
Smaller duct = greater resistance to airflow. More bends = greater resistance to airflow. Longer duct runs = increasingly reduced airflow. Wrinkled ducting causes turbulence and reducesairflow: WRINKLED DUCT AIRFLOW

Compare Centrifugal Against Axial Fan Performance:


SF100 (axial) vs an SF200 (centrifugal) fan. The starting point is the free air performance of 23 l/s for the axial and 31 l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29 l/s!
SF100 & SF200 PERFORMANCE GRAPH*

01

02

Smoother, extended ducting allows smooth, increased airflow: SMOOTH DUCT AIRFLOW

SF200

SF100 Manrose ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products. Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric. ID150 (axial) vs a MAN150 (centrifugal) fan. The starting point is the free air performance of 89 l/s for the axial and 115 l/s for the centrifugal.
*Graphs are a visual representation only.

Fan type
Centrifugal: Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms/laundries, multi-room extraction systems, heat-transfer systems, etc. Mixed Flow: Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise. Can handle more pressure than an axial fan, although not as powerful as a centrifugal fan. Axial: Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited. e.g. 100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length

As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120 Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving102 l/s!

72 144 216 288 360 432 504 300 250 200 150

30 25 20 15 10 5 0 20 40

MAN150

ID150
60 80 100 120 140

100 50

*Graphs are a visual representation only.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

Wet Areas & Recommended Fan Types


When considering where in the room to place an extractor fan, you must consider the wetareas. Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/ shower cubicle. A SELV fan or an in-line fan kit will be required in this zone. For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV). Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and up to 2.25 metres above thefloor. Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor. Zone 1: Zone 2: Zone 3:

Requires a SELV Fan or an In-Line fan kit Any fan model can be used Any fan model can be used

Locate your Ventilation Fan


Wet area zone guide

Outside Zones

Outside Zones

Zone 1: Requires a Low Voltage Fan. Zone 2: Any fan model can be used. Zone 3: Any fan models can be used.

How To Order
Select the model that exhausts the closest to your requirements. If the performance required falls between two fans, it is recommended you select the one handling the most air.

VENTILATION SELECTION
Fan Application Examples
Location of your ventilation fan will depend on the physical constraints of your room. The wet area zone guide (shown on the previous page) will help you decide the most suitable physical installation to meet yourrequirements. Within the above mounting options there are various other features available, such as:

TIMER (maintain fan run-on after the room is vacated). PULLCORD (Switch at fan, instead of wall switch control). AUTO-SHUTTER (electrically operated shutters inside the fan - closed when the fan is not running to stop draughts). PIR SENSOR (provide automatic motion-sensor control of fans).
1. Ceiling Mounted Fan Designed for low-pitch roofs or between floors, where there is no ceiling access. Also available with heat lamps & lighting.
01

4. In-Line Mounted Fan Kit Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in theroom.

04

Page Reference 12-21

2. Thru Wall Fan Kit Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan.
02 Page Reference 32-53

5. Thru Roof Kit Used where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl.
Page Reference 22-25 05

3. Window Mounted Fan Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access.
03

Page Reference 56-57

Page Reference 54-55

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

SELECTION CHART

Selecting the right fan is Easy

Wall/Ceiling Fans Room Size (m3)

Thru Wall Fan Kits

VA Lo-Carbon

Pro-Series

Classic

Pro-Series

Classic

ROOM TYPE

Toilets Laundries - No Dryer Basement Offices These rooms require between 6 and 10 ACH

1-5m3

LCS150

XFLP125

XF125

XPLP125

XP125

6-10m3

LCS150

XFLP125

XF125

XPLP125

XP125

11-15m3

LCS150

XFLP150

XF150

XPLP150

XP150

Bathrooms Showers Ensuites These rooms require between 11 and 15 ACH

1-10m3 11-15m3 16-20m3 21-30m3 1-5m3 6-10m3 11-20m3

LCS150 LCS150 LCS150 -

XFLP150 XFLP150 XFLP150

XF150 XF150 XF150 XFS230

XPLP150 XPLP150 XPLP150

XP150 XP150 XP150 XPS230

Kitchens Laundries - With Dryer These rooms require between 15 and 20 ACH

XFLP150 XFLP150

XF150 XF150 XF230

XPLP150 XPLP150

XP150 XP150 XPS230

3 Step Selection Guide


01 01

01

Select your required application, e.g. Bathrooms (11-15 air changes per hour). Calculate the volume of the room in cubic metres (m3) by multiplying the length x width x height E.g. 2.3m x 2.2m x 2.4m = 12.14m3 (Select a room volume 11-15m3).

02 02 02
03 03

10

HEAT/FAN/ LIGHT UNITS Pro-Series

IN-LINE FAN KITS

EXTRACT-A-LITE KITS

WINDOW FANS Pro-Series

THRU ROOF FAN KITS Classic

Pro-Series

Classic

Pro-Series

Classic

Heat n Vent 2

SFLP125

SF125

ELLP125

EL100

WF150

HYPER

Heat n Vent 2

SFLP125

SF125

ELLP125

EL125

WF150

HYPER

Heat n Vent 4

SFLP150

SF150

ELLP150

EL150

WF150

HYPER

Heat n Vent 2 Heat n Vent 4

SFLP150 SFLP150 SFLP150 MFLP150 SFLP150 SFLP150 MFLP150

SF150 SF150 SF150

ELLP125 ELLP150 ELLP150

EL150 EL150 EL150

WF150 WF150 WF150 WF230

HYPER HYPER ULTRA ULTRA HYPER HYPER ULTRA

SF150 SF150

ELLP125 ELLP150

EL150 EL150

WF150 WF150 WF230

03

Follow the 12m3 row across and select one of the fan kits available based on your mounting requirements (see top headings and photos). E.g. If you require a Thru Wall Kit then you can choose any of the XP150 or XPLP150 kits. Note: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum).

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

11

Manrose PRO-SERIES wall/ceiling mounted fans


xflp low profile models Square Models
Duct Size 125mm 125mm 150mm 150mm Model No. XFLP125SS XFLP125ST XFLP150SS XFLP150ST Switching Method Standard Timer Standard Timer Performance 36 l/s, 130m /hr 36 l/s, 130m3/hr 87 l/s, 313m /hr 87 l/s, 313m /hr
3 3 3

Order Code FAN0589 FAN0590 FAN0594 FAN0595

Circular Models
Duct Size 125mm 125mm 150mm 150mm Model No. XFLP125CS XFLP125CT XFLP150CS XFLP150CT Switching Method Standard Timer Standard Timer Performance 36 l/s, 130m3/hr 36 l/s, 130m /hr 87 l/s, 313m /hr 87 l/s, 313m /hr
3 3 3

Order Code FAN0604 FAN0605 FAN0609 FAN0610

Safety extra low voltage (selv) models


Duct Size 125mm 125mm 150mm 150mm Model No. XFLP125SLV XFLP125CLV XFLP150SLV XFLP150CLV Switching Method SELV 12V SELV 12V SELV 12V SELV 12V Performance 36 l/s, 130m3/hr 36 l/s, 130m3/hr 87 l/s, 313m3/hr 87 l/s, 313m /hr
3

Order Code FAN0591 FAN0606 FAN0596 FAN0611

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

ACCESSORIES
Duct Size 125mm 125mm 150mm 150mm Description: Circular Satin Silver Fascia Chrome Fascia Satin Silver Fascia Chrome Fascia Order Code FAN2069 FAN0757 FAN2070 FAN0613 Duct Size 125mm 125mm 150mm 150mm Description: Square Satin Silver Fascia Chrome Fascia Satin Silver Fascia Chrome Fascia Order Code FAN2068 FAN0755 FAN2071 FAN0598
LB
EA
R

Unique low profile design enables these fans to be installed unobtrusively into any wall or ceiling. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

IN

YEAR WARRANTY

GM

OT O R

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. 3. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

12

BAL

TECHNICAL DATA
General information
Models XFLP125S XFLP125C XFLP150S XFLP150C Circular Cut-Out Size 140mm - Using gib fixing clips supplied/included 140mm - Using gib fixing clips supplied/included 173mm - Using gib fixing clips supplied/included 173mm - Using gib fixing clips supplied/included

DIMENSION INFORMATION (mm)


Models XFLP125S XFLP125C XFLP150S XFLP150C A 161 165 191 198 B 122 122 122 122 C 10 10 10 10 D 118 118 150 150
A

Dimensions - XFLP

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating XFLP125 220 - 240V (SELV models 12V) 36 l/s, 130m /hr 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4
3

XFLP150 220 - 240V (SELV models 12V) 87 l/s, 313m3/hr 25W 60 Pa 2400 RPM 40 dB(A) 50C IPX4

Performance - XFLP125

Performance - XFLP150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

13

Manrose CLASSIC WALL/CEILING MOUNTED FANS


XF Models STANDARD Models
Duct Size 100mm 100mm 100mm 125mm 125mm 125mm 150mm 150mm 150mm 150mm Model No. XF100S XF100P XF100T XF125S XF125P XF125T XF150S XF150P XF150T XF150PIR Switching Method Standard Pull Cord Timer Standard Pull Cord Timer Standard Pull Cord Timer PIR Control Performance 23 l/s, 85m /hr 23 l/s, 85m /hr 23 l/s, 85m3/hr 36 l/s, 130m /hr 36 l/s, 130m3/hr 36 l/s, 130m /hr 87 l/s, 313m3/hr 87 l/s, 313m /hr 87 l/s, 313m3/hr 87 l/s, 313m /hr
3 3 3 3 3 3

Order Code FAN0046 FAN0047 FAN0048 FAN0072 FAN0074 FAN0075 FAN0120 FAN0126 FAN0127 FAN0124
Standard Model

AUTO SHUTTER Models


Duct Size 150mm 150mm 150mm Model No. XF150A XF150AP XF150AT Switching Method Standard Pull Cord Timer Performance 87 l/s, 313m3/hr 87 l/s, 313m3/hr 87 l/s, 313m3/hr Order Code FAN0121 FAN0122 FAN0123

Safety extra low voltage (selv) models


Duct Size 100mm 125mm 150mm Model No. XF100LV XF125LV XF150LV Switching Method SELV 12V SELV 12V SELV 12V Performance 23 l/s, 85m3/hr 36 l/s, 130m /hr 87 l/s, 313m3/hr
3

Auto Shutter Model

Order Code FAN0044 FAN0071 FAN0119

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

Safety Model (SELV)

Designed for wall or ceiling mounting, these models are efficient and easy to install. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.
Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan.

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. PIR Model - Motion sensor incorporated in fan. 6. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery

14

TECHNICAL DATA
GENERAL INFORMATION
Models XF100 XF125 XF150 Circular Cut-Out Size 112mm 135mm 160mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm)


Models XF100 XF125 XF150 XF150PIR XF150A/AP A 155 168 200 200 200 B 98 118 148 148 148 C 74 74 74 90 90 D 27 27 27 55 55 E 155 168 200 200 200

Dimensions - XF

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating XF100 220 - 240V (LV models 12V) 23/s, 85m /hr 20W 20 Pa 2400 RPM 41 dB(A) 50C IPX4
3

XF125 220 - 240V (LV models 12V) 36 l/s, 130m /hr 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4
3

XF150 220 - 240V (LV models 12V) 87 l/s, 313m3/hr 25W 60 Pa 2400 RPM 40 dB(A) 50C IPX4

Performance - XF100

Performance - XF125

Performance - XF150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

15

Manrose CLASSIC WALL/CEILING FANS


XFS COMMERCIAL Models
Duct Size Model No. Switching Method 230mm 300mm 300mm XFS230S XFS300S XFS300S Standard Standard Standard Performance 152 l/s, 550m3/hr 306 l/s, 1100m /hr 306 l/s, 1100m /hr
3 3

Order Code FAN0374 FAN2040 FAN2040

AUTO SHUTTER Models


Commercial Models

Duct Size 230mm 300mm

Model No. XFS230A XFS300A

Switching Method Standard Standard

Performance 152 l/s, 550m /hr 306 l/s, 1100m3/hr


3

Order Code FAN0346 FAN2041

Auto Shutter Models

Manrose Classic THRU WALL FAN KITS


XPS COMMERCIAL Models

Duct Size Model No. 230mm 300mm XPS230S XPS300S

Switching Method Standard Standard

Performance 152 l/s, 550m3/hr 306 l/s, 1100m /hr


3

Order Code FAN0455 FAN2042

AUTO SHUTTER Models


Commercial Models

Duct Size 230mm 300mm

Model No. XPS230A XPS300A

Switching Method Performance Standard Standard 152 l/s, 550m3/hr 306 l/s, 1100m /hr
3

Order Code FAN0348 FAN2043

Auto Shutter Models

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

16

TECHNICAL DATA
GENERAL INFORMATION
Models XFS230 XFS300 XPS230 XPS300 Fan Cut-Out Size 265mm 310mm 265mm 310mm Exterior Grille White Fixed Grille White Fixed Grille Duct Type Aluminium Semi-Rigid Aluminium Semi-Rigid Duct Length 375mm 375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm)


Models XFS230 XFS300 XPS230 XPS300 A 286 362 286 362 B 230 300 230 300 C 141 156 141 156 D 75 81 75 81 E 66 75 286 350 F 250 230 G 375 375 H 248 298 I 30 50

Dimensions - XF230/300

Dimensions - XPS230/300

C E A B

I
E F

G H B

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating XFS230 220 - 240V 152 l/s, 550m/hr 45W 50 Pa 1250 RPM 50 dB(A) 50C IPX4 XFS300 220 - 240V 306 l/s, 1100m/hr 82W 60 Pa 1300 RPM 60 dB(A) 50C IPX4
Performance - XFS230

XPS230 220 - 240V 152 l/s, 550m/hr 45W 50 Pa 1250 RPM 50 dB(A) 50C IPX4

XPS300 220 - 240V 306 l/s, 1100m/hr 82W 60 Pa 1300 RPM 60 dB(A) 50C IPX4
Performance - XFS300

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

17

WHISPERVENT CEILING FANS


CENTRIFUGAL CEILING FAN MODELS
Duct Size 100mm 100mm 150mm Model No. WVC100W WVC100S WVC150S Colour White Stainless White Performance 63 l/s, 225m3/hr 63 l/s, 225m3/hr 100 l/s, 360m3/hr Order Code FAN0884 FAN0885 FAN2465

NEW

Designed for apartments where space is limited, these ceiling mounted fans can be installed in confined spaces. The centrifugal fan design assistswhisper quiet operation. Reliable long lasting ball bearinng motor Supported by a 3 year warranty.

Simx Whispervent 150 - White

Simx Whispervent 100 - Silver

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied).

18

TECHNICAL DATA
Models WhisperVent 100 WhisperVent 150 A 240 310 B 290 330

DIMENSION INFORMATION (mm)


C 172 370 D 98 37 184 30 E F

Dimensions - WhisperVent 100

Dimensions - WhisperVent 150

D C
C

B
D

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating WhisperVent 100 220 - 240V 63 l/s, 225m /hr 30W 105 Pa 2500 RPM 38 dB(A) 40oC IPX4
3

WhisperVent 150 220 - 240V 100 l/s, 360m3/hr 42W 145 Pa 2500 RPM 44 dB(A) 40oC IPX4

Performance - WhisperVent 100

Performance - WhisperVent 150

Airflow (m/hr)
0 160 50 100 150 200 250 300 350 400

50

100

150

200

250
140

120

100

Pressure (Pa)

80

60

40

20

15

30

45

60

75

0 0 20 40 60 80 100 120

Airflow (l/s)

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

19

Manrose CLASSIC Multi-Vent Fans


FLUSH FITTING RANGE
Switching Method Standard Timer PIR Performance @ Speed 3 65 l/s, 234m3/hr 65 l/s, 234m3/hr 65 l/s, 234m3/hr

Duct Size Model No. 100mm 100mm 100mm FFCF234S FFCF234T FFCF234PIR

Order Code FAN0038 FAN0499 FAN0501

SURFACE MOUNT RANGE


Duct Size Model No. 100mm 100mm SMCF234S SMCF234T Switching Method Standard Timer Performance @ Speed 3 65 l/s, 234m3/hr 65 l/s, 234m3/hr Order Code FAN0504 FAN0505

Flush Fitting Range

Designed for apartments where space is limited, with a choice of wall or ceiling mounted system. These Models include centrifugal fans with a choice of three in-built speed settings depending on the performance required. Supported by a 2 year warranty.

Manrose CLASSIC WALL FAN


CF CENTRIFUGAL MODELS
Duct Size Model No. 100mm 100mm CF200S CF200TP Switching Method Standard Timer Performance @ Speed 1 31 l/s, 110m3/hr 31 l/s, 110m3/hr Order Code FAN0041 FAN0042
CF Centrifugal Model

Designed to move air over long distances. The centrifugal fan design provides efficient airflow and quiet operation. Supported by a 2 year warranty.

YEAR WARRANTY

1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

3. PIR Model - Motion sensor incorporated in fan. Range up to 5 metres. NOTE: All fan flow rates quoted are free air delivery.

20

TECHNICAL DATA
Models Multi-Vent FFCF234 A 91 B 96 250 65

DIMENSION INFORMATION (mm)


C 141 15 185 D 250 119.5 260 E 15 22.5 45 F 155 63 98 G 210 249 90 H 135

Multi-Vent SMCF234 312 CF200 65

Dimensions - Multi-Vent (Flush Fitting)

Dimensions - CF200

Dimensions - Multi-Vent (Surface Mount)

B A D D C E G G
A

E C D G H F

C A

F G

TECHNICAL SPECIFICATION
Models Multi-Vent 1 Speed Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating 220 - 240V 28 l/s, 100m3/hr 40W 140 Pa 950 RPM 37 dB(A) 50C IPX4 2 Speed 220 - 240V 45 l/s, 162m3/hr 80W 165 Pa 1500 RPM 51 dB(A) 50C IPX4 3 Speed 220 - 240V 65 l/s, 234m3/hr 110W 180 Pa 1850 RPM 56 dB(A) 50C IPX4 220 - 240V 31 l/s, 110m3/hr 45W 120 Pa 1400 RPM 45 dB(A) 50C IPX4 CF200

Performance - Multi-Vent

Performance - CF200

Volume m3/hr

0 200 180 160 140


Static Pressure Pa

54

108

162

216

270

120 100 80 60 40 20 0 0 15 30 45 60 75

2 1

Volume l/sec

NOTE 1, 2, 3 refer to speed settings controlled by internal switch (not consumer adjustable).

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

21

Manrose Pro-Series THRU WALL mounted FAN kits


XPLP Low Profile Models STANDARD Models
Duct Size Model No. 125mm 125mm 150mm 150mm XPLP125SS XPLP125ST XPLP150SS XPLP150ST Switching Method Standard Timer Standard Timer Performance 36 l/s, 130m3/hr 36 l/s, 130m /hr 87 l/s, 313m3/hr 87 l/s, 313m /hr
3 3

Order Code FAN0614 FAN0615 FAN0621 FAN0623


Standard Models

Safety extra low voltage (selv) models


Duct Size Model No. 125mm 125mm 150mm 150mm XPLP125SLV XPLP125CLV XPLP150SLV XPLP150CLV Switching Method SELV 12V SELV 12V SELV 12V SELV 12V Performance 36 l/s, 130m3/hr 36 l/s, 130m3/hr 87 l/s, 313m /hr 87 l/s, 313m3/hr
3

Order Code FAN0620 FAN0735 FAN0732 FAN0738


Low Voltage Models

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

ACCESSORIES
Duct Size 125mm 125mm 150mm 150mm Description - Square Satin Silver Fascia Chrome Fascia Satin Silver Fascia Chrome Fascia Order Code FAN2068 FAN0755 FAN2071 FAN0598
Accessories - Square

Duct Size 125mm 125mm 150mm 150mm

Description - Circular Satin Silver Fascia Chrome Fascia Satin Silver Fascia Chrome Fascia

Order Code FAN2069 FAN0757 FAN2070 FAN0613


Accessories - Circular Fascia

The unique Low Profile design enables these fans to be installed unobtrusively into any wall (requires a minimum wall cavity of 110mm). These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

Note 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires permanent phase and switched phase. 3. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

22

Technical data
GENERAL INFORMATION
Models XPLP125 XPLP150 Fan Cut-Out Size 140mm 173mm Exterior Grille White Gravity Shutter White Gravity Shutter Duct Type Aluminium Semi-Rigid Aluminium Semi-Rigid Duct Length 375mm 375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm)


Models XPLP125 XPLP150 A 161 191 B 118 150 C 128 132 D 10 10 E 160 174 F 125 150 G 375 375 H 123 148 I 30 30

Dimensions - XPLP

I
E F

G H B A

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating XPLP125 220 - 240V (LV models 12V) 36 l/s, 130m /hr 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4
3

XPLP150 220 - 240V (LV models 12V) 87 l/s, 313m3/hr 25W 60 Pa 2400 RPM 40 dB(A) 50C IPX4

Performance - XPLP125

Performance - XPLP150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

23

Manrose CLASSIC THRU WALL MOUNTED FAN KITS


XP Models STANDARD Models
Duct Size 100mm 100mm 100mm 125mm 125mm 125mm 150mm 150mm 150mm Model No. XP100S XP100P XP100T XP125S XP125P XP125T XP150S XP150P XP150T Switching Method Standard Pull Cord Timer Standard Pull Cord Timer Standard Pull Cord Timer Performance 23 l/s, 85m3/hr 23 l/s, 85m /hr 23 l/s, 85m /hr 36 l/s, 130m /hr 36 l/s, 130m /hr 36 l/s, 130m3/hr 87 l/s, 313m /hr 87 l/s, 313m /hr 87 l/s, 313m /hr
3 3 3 3 3 3 3

Order Code FAN0053 FAN0054 FAN0055 FAN0080 FAN0082 FAN0083 FAN0135 FAN0140 FAN0141
Standard Models

AUTO SHUTTER Models


Duct Size 150mm 150mm 150mm Model No. XP150A XP150AP XP150AT Switching Method Standard Pull Cord Timer Performance 87 l/s, 313m3/hr 87 l/s, 313m /hr 87 l/s, 313m /hr
3 3

Order Code FAN0136 FAN0137 FAN0138


Auto Shutter Models

Safety extra low voltage (selv) models


Duct Size 100mm 125mm 150mm Model No. XP100LV XP125LV XP150LV Switching Method SELV 12V SELV 12V SELV 12V Performance 25 l/s, 85m3/hr 36 l/s, 130m /hr 87 l/s, 313m3/hr
3

Order Code FAN0409 FAN0410 FAN0411


Low Voltage Models

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

These fans are designed to be ducted straight through an exterior wall and are efficient and easy to install. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

Note 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

24

Technical data
GENERAL INFORMATION
Models XP100 XP125 XP150 Fan Cut-Out Size 112mm 135mm 160mm Exterior Grille Grey Gravity Shutter Grey Gravity Shutter Grey Gravity Shutter Duct Type Aluminium Semi-Rigid Aluminium Semi-Rigid Aluminium Semi-Rigid Duct Length 375mm 375mm 375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm)


Models XP100 XP125 XP150 XP150A
Dimensions - XP

A 155 168 200 200

B 98 118 148 148

C 74 74 74 90

D 27 27 27 55

E 138 160 174 174

F 100 125 150 150

G 375 375 375 375

H 98 123 148 148

I 30 30 30 30

C
I

G F H B

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating
Performance - XP100

XP100 220 - 240V (SELV models 12V) 23 l/s, 85m/hr 20W 20 Pa 2400 RPM 41 dB(A) 50C IPX4

XP125 220 - 240V (SELV models 12V) 36 l/s, 130m/hr 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4
Performance - XP125

XP150 220 - 240V (SELV models 12V) 87 l/s, 313m/hr 25W 60 Pa 2400 RPM 40 dB(A) 50C IPX4
Performance - XP150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

25

Manrose CLASSIC WINDOW MOUNTED FANS


WF Models STANDARD Models
Duct Size Model No. 100mm 100mm WF100P WF100PLV Switching Method Pull Cord Low Voltage Performance 23 l/s, 85m3/hr 23 l/s, 85m3/hr Order Code FAN0021 FAN0452

Manual SHUTTER Models


Standard Models

Duct Size Model No. 150mm 150mm WF150MP WF150MPLV

Switching Method Pull Cord SELV 12

Performance 87 l/s, 313m3/hr 87 l/s, 313m3/hr

Order Code FAN0110 FAN0355

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

AUTO SHUTTER Models


Duct Size Model No. 150mm 150mm WF150AP WF150APT Switching Method Pull Cord Pull Cord Timer Performance 87 l/s, 313m3/hr 87 l/s, 313m3/hr Order Code FAN0107 FAN0109

Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty.

Auto Shutter Models

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

26

Technical data
GENERAL INFORMATION
Models WF100 WF150 Glass Cut-Out Size 115mm - 155mm 165mm - 190mm

Please note: Glass cut out size is a nominal diameter for a circular cut-out.

DIMENSION INFORMATION (mm)


Models WF100 WF150 A 163 203 B 90 118 C 30 23 D 163 203

Dimensions - WF

B A

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating WF100 220 - 240V 23 l/s, 85m/hr 20W 20 Pa 2400 RPM 41 dB(A) 50oC IPX4 WF150 220 - 240V (SELV models 12V) 87 l/s, 313m/hr 25W 60 Pa 2400 RPM 40 dB(A) 50oC IPX4

Performance - WF100

Performance - WF150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

27

Manrose CLASSIC WINDOW COMMERCIAL FANS


WF Commercial MODELS Standard Models
Duct Size Model No. Switching Method 230mm 300mm WF230P WF300P Pull Cord Pull Cord Performance 152 l/s, 550m3/hr 306 l/s, 1100m3/hr Order Code FAN0148 FAN0481

AUTO SHUTTER Models


Standard Larger Models

Duct Size Model No. Switching Method 230mm 300mm WF230AP WF300A Pull Cord Standard

Performance 152 l/s, 550m3/hr 306 l/s, 1100m3/hr

Order Code FAN0146 FAN0482

Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty.

Auto Shutter Models

Manrose CLASSIC WINDOW COMMERCIAL FANS


COM Commercial Models
Duct Size Model No. 230mm 230mm 300mm 300mm COM230A Switching Method Standard Performance 185 l/s, 670m3/hr 185 l/s, 670m3/hr 280 l/s,1020m3/hr 280 l/s,1020m3/hr Order Code FAN0519 FAN0518 FAN0521 FAN0520
Commercial Auto Shutter Models

COM230MP Pull Cord COM300A Standard

COM300MP Pull Cord

BAL

LB

EA

Designed for commercial applications such as pubs, restaurants, hotels, shops etc. These axial fans include ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

IN

YEAR WARRANTY

GM

OT O R

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan. 4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

28

Technical data
GENERAL INFORMATION
Models WF230 WF300 COM230 COM300 Glass Cut-Out Size 255mm - 270mm 310mm - 345mm 255mm - 270mm 310mm - 345mm
A
Dimensions - COM230/300 Dimensions - WF230/300

Please note: Glass cut out size is a nominal diameter for a circular cut-out.

DIMENSION INFORMATION (mm)


Models WF230 WF300 COM230 COM300 A 286 362 286 362 B 286 362 125 145 C 4-32 4-32 25 25 D 112 133 154 170 E 25 29 A

D C

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp WF230 220 - 240V 152 l/s, 550m /hr 45W 50 Pa 1250 RPM 50 dB(A) 50C
3

WF300 220 - 240V 306 l/s, 1100m /hr 82W 60 Pa 1300 RPM 60 dB(A) 50C
3

COM230 220 - 240V 185 l/s, 670m /hr 45W 50 Pa 1600 RPM 53 dB(A) 50C
3

COM300 220 - 240V 280 l/s, 1020m3/hr 82W 60 Pa 1300 RPM 60 dB(A) 50C

Performance - WF230

Performance - WF300

Volume m 3/hr 0 250 500 750

Performance - COM230

Volume m 3/hr 0 300 600 900 1200 1500

Performance - COM300

55
Static Pressure Pa

55

Static Pressure Pa

40

40

25

25

0 0 70 140 Volume l/sec 210

0 0 83 168 250 333 416 Volume l/sec

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

29

Manrose PRO-SERIES HEAT/FAN/LIGHT KITS


Heat n Vent Models
Duct Size Model No. 125mm 125mm Heat n Vent 4 Heat n Vent 2 Performance 60 l/s, 216m3/hr 50 l/s, 180m3/hr Order Code FAN0995 FAN0940
Pro-Series Heat n Vent 4

ACCESSORIES
Duct Size Description 125mm 125mm Heat n Vent 4 Silver Fascia Heat n Vent 2 Silver Fascia 275W Heat Lamp 50W Halogen GU10 lamp Order Code FAN1015 FAN1014 LHT0081 LHT0140

Pro-Series Heat n Vent 2

With a 40% increase in performance* these systems meet the demands of larger bathrooms and the stylish fascia blends into the decor. These high efficiency centrifugal fans incorporate a unique anti-condensate design feature. Supported by a 5 year warranty.

Manrose CLASSIC Heat/FAN/LIGHT KIT


Heat n Vent 2
Duct Size Model No. 100mm Heat n Vent 2 Performance 35 l/s, 126m3/hr Order Code FAN2162
Classic Heat n Vent 2

This system delivers instant heat combined with ventilation and soft lighting to create a comfort area in small bathrooms. Supported by a 5 year warranty.

Manrose CLASSIC Heat/LIGHT KIT


2 Heat n LIGHT
Duct Size Description 100mm 2 Heat n Light (excludes fan) Order Code FAN2200
2 Heat n Light

BAL

LB

This system provides instant heat and additional lighting. For a complete bathroom solution an extraction fan can be added. Supported by a 5 year warranty.
Switching Options 1. Standard Model - operates from remote switch (not supplied). *Increase in performance is based on the comparison to the previous models.

EA

IN

YEAR WARRANTY

GM

OT O R

NOTE: All fan flow rates quoted with 3 metres of duct, one bend and one external grille (normal installation).

30

Technical data
GENERAL INFORMATION
Models PS Heat n Vent 4 PS Heat n Vent 2 Classic Heat n Light Cut-Out Size 300mm x 300mm 390mm x 210mm 390mm x 220mm Exterior Grille White Eggcrate White Eggcrate White Eggcrate Duct Type Aluminium Aluminium Aluminium Duct Length 3m supplied (you can add up to 3m extra duct) 3m supplied (you can add up to 3m extra duct) 3m supplied (you can add up to 3m extra duct) -

Classic Heat n Vent 2 390mm x 220mm

DIMENSION INFORMATION (mm)


Models PS Heat n Vent 4 PS Heat n Vent 2 Heat n Vent Heat n Light A 338 435 450 450 B 338 260 250 250 C 170 185 195 195 D 120 120 100 100
Dimensions - Classic Heat n Vent Dimensions - Classic 2 Heat n Light

Dimensions - PS Heat n Vent 4

Dimensions - PS Heat n Vent 2

D C C B A B A

D C B A

D C B

TECHNICAL SPECIFICATION
Models Power Fan Fan Performance Heat Lamps Light Total Wattage Light Wattage Switch Plate Warranty
Performance Graph

PS Heat n Vent 4 220 - 240V Centrifugal 60 l/s, 216m/hr 4 x 275W GU10 Halogen 1180W 50W 4 sw. (supplied) 5 Years

PS Heat n Vent 2 220 - 240V Centrifugal 50 l/s, 180m/hr 2 x 275W GU10 Halogen 635W 50W 3 sw. (supplied) 5 Years

Heat n Vent 2 220 - 240V Centrifugal 35 l/s, 126m/hr 2 x 275W GLES 670W 100W 3 sw. (supplied) 5 Years

2 Heat n Light 220 - 240V 2 x 275W GLES 650W 100W 2 sw. (supplied) 5 Years

Icon Key
36 72 108 144 180 216 252 288

01 02 03
02 01

Pro-Series Heat n Vent 4 Pro-Series Heat n Vent 2 Classic Heat 'n Vent 2

03

Note: Performance tested in free air.


70

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

31

PRO-SERIES IN-LINE MOUNTED FAN KITS


MIXFLO Shower Fan Models
Duct Size Model No. 100mm 125mm 150mm MFLP100S MFLP125S MFLP150S Switching Method Standard Standard Standard Performance 69 l/s, 250m3/hr 89 l/s, 320m /hr 166 l/s, 597m /hr
3 3

Order Code FAN2049 FAN2050 FAN2051


MKLP150

BAL

LB

EA

These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. Supported by a 5 year warranty.

IN

GENERAL INFORMATION (KITS)


Models Grille Cut-Out Interior Grille White Low Profile White Low Profile White Low Profile Exterior Grille Duct Type Duct Length

YEAR WARRANTY

GM

OT O R

MFLP100 115mm MFLP125 140mm MFLP150 160mm

White Low Profile Unilok Nude White Low Profile Unilok Nude White Low Profile Unilok Nude

6m supplied (you can add up to 6m extra duct) 6m supplied (you can add up to 6m extra duct) 6m supplied (you can add up to 6m extra duct)

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied).

32

Technical data
Models MF100 MF125 MF150 A 98 122 147 B 182 182 209 C 315 350 360 D 100 100 130

Dimension INFORMATION (mm)


E 100 100 115 F 168 168 195 G 27 60 55
Dimensions - MF

TECHNICAL SPECIFICATION
Model No MF100 MF125 MF150 Size (mm) 100 125 150 RPM Watts 2300 40 1700 18 2300 40 1700 18 2700 70 2000 60 Maximum Airflow (m/hr) 250 190 320 260 597 330 Maximum Pressure (Pa) 180 120 220 160 300 240 Lp dB(A) 3m* 40 43 47 IP Rating X4 X4 X4 Max Operating Temp C 45 45 60

Performance - MF100

Performance - MF125

Performance - MF150

Airow (m3/hr) 0 200 180 160 140 Pressure (Pa) 200 50 100 150 200 250 300 250 0 50 100

Airow (m3/hr) 150 200 250 300 350 350 300 250 Pressure (Pa) Pressure (Pa) 150 200 150 100 50 50 0 0 0 20 40 Airow (L/s) 60 80 100 0 50 0 100

Airow (m3/hr) 200 300 400 500 600 700

120 100 80 60 40 20 0 0 20 40 Airow (L/s) 60 80

100

100 Airow (L/s)

150

200

* Lp dB(A) @ 3 metres - sound pressure based on the high speed for each fan.

SOUND POWER LEVEL (high speed)


Model No Sound Power Levels Lw (dB) Octave band centre frequency in Hz 125 MF100 MF125 MF150 50 52 58 250 56 59 66 500 58 60 65 1000 2000 4000 8000 58 60 63 52 56 62 47 49 54 37 41 46 61 63.5 67.5 LwA dB(A)

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

33

Manrose PRO-SERIES IN-LINE FANS KITS


SFLP Shower Fan Models
Duct Size 125mm 125mm 150mm 150mm Switching Method Standard Timer Standard Timer

Model No. SFLP125S SFLP125T SFLP150S SFLP150T

Fan Type Ctrfgl Ctrfgl Whisper Whisper

Performance 39 l/s, 140m/hr 39 l/s, 140m/hr 94 l/s, 340m/hr 94 l/s, 340m/hr

Order Code FAN0616 FAN0617 FAN0618 FAN0619


BAL

SFLP150
IN

YEAR WARRANTY

GM

OT O R

These high efficiency in-line fans are designed to provide higher levels of extraction for todays larger bathrooms. Supported by a 5 year warranty.

General INFORMATION
Grille Cut-Out

Models

Interior Grille White Low Profile White Low Profile

Exterior Grille White Low Profile White Low Profile

Duct Type Flexible Aluminium Flexible PVC

Length of Duct included 4m supplied (can be extended up to 6m) 5m supplied (can be extended up to 12m)

SFLP125 140mm SFLP150 160mm

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require three wires: permanent phase, switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

34

LB

EA

Technical data
Models SFLP125 SFLP150 A 155 200 B 125 143 C

Dimension INFORMATION (mm)


D 195 185 E 258 -

125 170

Dimensions - SFLP125

Dimensions - SFLP150

A B A C D

TECHNICAL SPECIFICATION
Models Fan Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating SFLP125 CFD225 220 - 240V 39 l/s, 140m/hr 20W 120 Pa 1400 RPM 45 dB(A) 50C IPX4 SFLP150 WhisperVent 220 - 240V 94 l/s, 340m/hr 46W 160 Pa 2750 RPM 38 dB(A) 80C IPX2

Performance - SFLP125

Performance - SFLP150

36

72

108 144

180

216

252

288

324 360

70

90

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

35

Manrose CLASSIC IN-LINE FAN KITS


SF Shower Fan Models
Model No. SF100S SF100T SF200S SF200T SF125S SF125T SF150S SF150T Switching Method Standard Timer Standard Timer Standard Timer Standard Timer Fan Type Axial Axial Ctrfgl Ctrfgl Axial Axial Axial Axial

Duct Size 100mm 100mm 100mm 100mm 125mm 125mm 150mm 150mm

Performance 23 l/s, 85m3/hr 23 l/s, 85m3/hr 31 l/s, 110m3/hr 31 l/s, 110m3/hr 36 l/s, 130m3/hr 36 l/s, 130m3/hr 87 l/s, 320m3/hr 87 l/s, 320m3/hr

Order Code FAN0017 FAN0018 FAN0328 FAN0329 FAN0064


BAL

SF150 Shower Fan Kit


GM

FAN0065 FAN0101 FAN0102

LB

EA

IN

YEAR WARRANTY

OT O R

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from source. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

GENERAL INFORMATION
Models SF100 SF200 SF125 SF150 Grille Cut-Out 115mm 115mm 140mm 160mm Interior Grille White Circular White Circular White Circular White Circular Exterior Grille Duct Type Length of Duct included 3m supplied (should not be extended) 3m supplied (can be extended up to 6m) 4m supplied (should not be extended) 5m supplied (can be extended up to 12m)

White Fixed Louvre Flexible PVC White Fixed Louvre Flexible Alum White Fixed Louvre Flexible PVC White Fixed Louvre Flexible PVC

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require: permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

36

Technical data
Models SF100 SF200 SF125 SF150 A 130 155 150 187 B 155 100 155 153 C 90 100 99 109 D 100 195 118 150

DIMENSION INFORMATION (mm)


E 27 258 27 27

TECHNICAL SPECIFICATION
Models Fan Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max Operating Temp IP Rating SF100 ID100 220 - 240V 23 l/s, 85m/hr 20W 20 Pa 2400 RPM 41 dB(A) 50C IPX4 SF200 CFD200 220 - 240V 31 l/s, 110m/hr 20W 120 Pa 1400 RPM 45 dB(A) 50C IPX4 SF125 ID125 220 - 240V 36 l/s, 130m/hr 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4 SF150 Hyper 220 - 240V 89 l/s, 320m/hr 38W 135 Pa 2650 RPM 46 dB(A) 70C IPX2
E
Performance - SF200 Dimensions - SF100/SF125/150

C A D

B
Dimensions - SF200

Performance - SF100

Performance - SF125

Performance - SF150 Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

37

Manrose PRO-SERIES IN-LINE FAN/LIGHT KITS


ELLP Extract-a-lite Low Profile Models
Switching Method Standard Timer Standard Timer Standard Timer* Standard Timer*

Duct Size 125mm 125mm 125mm 125mm 150mm 150mm 150mm 150mm

Model No. ELLP125WS - Wht ELLP125WT - Wht ELLP125SS - Slv ELLP125ST - Slv ELLP150WS - Wht ELLP150WT - Wht ELLP150SS - Slv ELLP150ST - Slv

Performance 39 l/s, 140m3/hr 39 l/s, 140m3/hr 39 l/s, 140m /hr 39 l/s, 140m /hr 94 l/s, 340m /hr 94 l/s, 340m3/hr 94 l/s, 340m /hr 94 l/s, 340m /hr
3 3 3 3 3

Order Code FAN2029 FAN2031 FAN2030 FAN2032 FAN2033 FAN2035 FAN2034 FAN2036
ELLP125SW

* Includes a 7 minute fixed timer

ACCESSORIES
Duct Size 125mm 125mm 150mm 150mm Description Pro-Series ELLP Diffuser White incl lamp Pro-Series ELLP Diffuser Silver incl lamp Pro-Series ELLP Diffuser White incl lamp Pro-Series ELLP Diffuser Silver incl lamp 12V 35-50W Dichroic lamp with 60 angle beam Electronic Transformer 12VAC 50kHz Order Code DCT1519 DCT1520 DCT1521 DCT1522 FAN0431 FAN2101

BAL

LB

These high efficiency in-line fans are designed to provide higher levels of extraction for larger bathrooms and include a stylish downlight. White or satin silver finish available to complement your bathroom decor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty.

ELLP150SS
GM
OT O R

EA

IN

YEAR WARRANTY

125mm ELLP Diffusers

GENERAL INFORMATION
Models ELLP125W Diffuser Cut-Out 140mm Interior White Extract-a-lite incl light Satin Silver Extract-a-lite incl light White Extract-a-lite incl light Satin Silver Extract-a-lite incl light Exterior Grille White Low Profile White Low Profile White Low Profile White Low Profile Duct Type Black Unilok Black Unilok Black Unilok Black Unilok Length of Duct included 6m supplied (you can add up to 6m extra duct) 6m supplied (you can add up to 6m extra duct) 6m supplied (you can add up to 6m extra duct) 6m supplied (can be extended up to 12m)

ELLP125SS 140mm ELLP150W 165mm

ELLP150SS 165mm

Please note: Diffuser cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require: permanent phase, and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

38

Technical data
Models ELLP125 ELLP150 A 155 200 B 125 143 C

DIMENSION INFORMATION (mm)


D 195 185 E 258 F 165 200 G 80 80 H 110 148

125 170

Dimensions - ELLP125 Fan

Dimension - ELLP150 Fan

Dimensions - ELLP Extract-a-lite Diffuser

A B A C

C G

D F

TECHNICAL SPECIFICATION
Models Fan Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Light Total Wattage Sound Level Max. Operating Temp IP Rating ELLP125 CFD225 220 - 240V 39 l/s, 140m/hr 20W 120 Pa 1400 RPM 12V 50W Halogen 99W 45 dB(A) 50C IPX4 ELLP150 WhisperVent 220 - 240V 94 l/s, 340m/hr 46W 160 Pa 2750 RPM 12V 50W Halogen 96W 38 dB(A) 80C IPX2

Performance - ELLP125

Performance - ELLP150

36

72

108 144

180

216

252

288

324 360

70

90

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

39

Manrose CLASSIC IN-LINE FAN/LIGHT KITS


EL Extract-a-lite Models
Duct Size 100mm 100mm 125mm 125mm 150mm 150mm Model No. EL100S EL100T EL125S EL125T EL150S EL150T Switching Method Performance Standard Timer Standard Timer Standard Timer* 31 l/s, 110m3/hr 31 l/s, 110m /hr 36 l/s, 130m /hr 36 l/s, 130m /hr 89 l/s, 320m3/hr 89 l/s, 320m3/hr
3 3 3

Order Code FAN0420 FAN0438 FAN2037 FAN2038 FAN0804


LB
EA

EL150S

FAN0803

BAL

R
BAL

IN

* Includes a 7 minute fixed timer.

YEAR WARRANTY

GM

OT O R

The fan is mounted in the ceiling space, and is therefore able to draw steam directly from source, while at the same time providing spot lighting within your bathroom. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty.

ACCESSORIES
Duct Size 100mm 100mm 125mm 125mm 150mm 150mm 100mm 125mm 150mm Description EL Diffuser white incl lamp EL Diffuser chrome incl lamp EL Diffuser white incl lamp EL Diffuser chrome incl lamp EL Diffuser white incl lamp EL Diffuser chrome incl lamp Accessory chrome bezel - Extract-a-lite Accessory chrome bezel - Extract-a-lite Accessory chrome bezel - Extract-a-lite 12V 35-50W Dichroic lamp with 60 angle beam Electronic Transformer 12VAC 50kHz Order Code DCT0360 DCT0362 DCT2121 DCT2120 DCT1169 DCT1171 DCT0366 FAN2076 FAN0431 FAN2101
LB

125mm EL Diffusers

FAN0827

EA

IN

YEAR WARRANTY

GM

OT O R

GENERAL INFORMATION
Models EL100 EL125 EL150 Diffuser Cut-Out 115mm 145mm 165mm Interior White Extract-a-lite incl light White Extract-a-lite incl light White Extract-a-lite incl light Exterior Grille Duct Type White Eggcrate White Eggcrate White Eggcrate Flexible PVC Flexible PVC Flexible PVC Length of Duct included 3m supplied (should not be extended) 4m supplied (should not be extended) 5m supplied (you can add up to 12m extra duct)

Please note: Diffuser cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require: permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

40

Technical data
Models EL100 EL125 EL150 A 130 150 200 B 155 155 143 C 90 99

DIMENSION INFORMATION (mm)


D 100 118 185 E 27 27 F 140 170 200 G 74 74 74 H 98 118 148

170

Dimensions - EL100

Dimensions - EL125

Dimensions - EL150 Fan

C B A C D A D

TECHNICAL SPECIFICATION
Models Fan Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Light Total Wattage Sound Level Max. Operating Temp IP Rating EL100 CFD200 220 - 240V 31 l/s, 110m3/hr 20W 120 Pa 1400 RPM 12V 50W Halogen 70W 45 dB(A) 40C IPX4 EL125 ID125 220 - 240V 36 l/s, 130m3/hr 25W 35 Pa 2000 RPM 12V 50W Halogen 75W 41 dB(A) 40C IPX4 EL150 Hyper 220 - 240V 89 l/s, 320m3/hr 38W 135 Pa 2650 RPM 12V 50W Halogen 88W 46 dB(A) 70C IPX2
F G H
Dimensions - EL Extract-a-lite Diffuser

Performance - EL100

Performance - EL125

Performance - EL150

36

72

108 144

180

216

252

288

324 360

70

90

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

41

Pro-Series IN-LINE MIXED FLOW FANS


MIXFLO Fan Models
Duct Size 100mm 100mm 100mm 125mm 125mm 125mm 150mm 150mm 150mm 200mm 200mm 200mm Model No. MF100S MF100T Switching Method Standard Timer Speed Setting 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 3 Speed 2 Speed 3 Speed Performance @ High Speed 69 l/s, 250m3/hr 69 l/s, 250m3/hr 69 l/s, 250m3/hr 89 l/s, 320m3/hr 89 l/s, 320m3/hr 89 l/s, 320m /hr 166 l/s, 597m3/hr 166 l/s, 597m3/hr 166 l/s, 597m /hr 272 l/s, 980m3/hr 272 l/s, 980m3/hr 272 l/s, 980m3/hr
3 3

Order Code FAN1004 FAN2124 FAN1050 FAN1005 FAN2125 FAN1051 FAN1006 FAN2126 FAN1048 FAN1007 FAN2127 FAN1053
Mixflow 150mm Standard Model

MF100PL Plug & Lead MF125S MF125T Standard Timer

MF125PL Plug & Lead MF150S MF150T Standard Timer

MF150PL Plug & Lead MF200S MF200T Standard Timer

YEAR WARRANTY

MF200PL Plug & Lead

These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. Supported by a four year warranty or 30,000 continuous hours.

Dimension information (mm)


Dimensions - MF

Models
MF100 MF125 MF150 MF200

A
98 122 147 197

B
182 182 209 244

C
315 350 360 354

D
100 100 130 142

E
100 100 115 140

F
168 168 195 230

G
27 60 55 50

Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

42

Technical data
230V/50Hz/1 Model No. Speed (rev/ min) Motor Input (W) Max Temp (C)

technical specification SOUND POWER LEVEL (high speed)


Model No. 125 Sound Power Levels LwA (dB) Octave band centre frequency in Hz 250 500 1000 2000 4000 8000

Sound Pressure Level (dBA@3m)

MF100

2300 1700 2300 1700 2700 2000 2700

0.40 0.18 0.40 0.18 0.70 0.60 0.85 0.60 0.45

45 45 45 45 60 60 60 60 60

40 33 43 36 47 40 48 45 41

MF100 MF125 MF150 MF200

50 52 58 65

56 59 66 69

58 60 65 64

58 60 63 63

52 56 62 62

47 49 54 60

37 41 46 48

MF125

MF150

MF200

2350 2000

Performance - MF100

Performance - MF125

Airow (m3/hr) 0 200 180 160 140 Pressure (Pa) 120 100 80 60 40 20 0 0 20 40 Airow (L/s) 60 80 0 0 20 50 Pressure (Pa) 150 200 50 100 150 200 250 300 250 0 50 100

Airow (m3/hr) 150 200 250 300 350

Icon Key
Speed 1 Speed 2 Speed 3

100

40 Airow (L/s)

60

80

100

Performance - MF150

Performance - *MF200 *MF200 Timer model only has 2 speeds, therefore Medium fan speed specifications will not apply.

Airow (m3/hr) 0 350 300 250 200 Pressure (Pa) 200 150 100 50 0 0 50 100 Airow (L/s) 150 200 Pressure (Pa) 100 200 300 400 500 600 700 300 0 200

Airow (m3/hr) 400 600 800 1000

250

150

100

50

0 0 50 100 150 200 250 300 Airow (L/s)

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

43

Manrose PRO-SERIES IN-LINE WHISPERVENT FAN


Switching Performance Method Standard 94 l/s, 340m3/hr

Duct Size Model No. 150mm Whispervent WVI150

Order Code FAN0916

BAL

This high efficiency in-line fan is designed to provide higher levels of extraction with low relative noise. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty.

LB

EA

IN

YEAR WARRANTY

GM

OT O R

Manrose CLASSIC IN-LINE Hyper FAN


Duct Size Model No. 150mm Hyper150 Switching Performance Method Standard 89 l/s, 320m3/hr Order Code FAN0085

This high efficiency in-line fan is designed to provide high levels of extraction. The ball bearing motor prolongs the life of the motor. Includes 1.3m lead and 3 pin plug. Supported by a 5 year warranty.

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

44

Technical data
Models WVI150 Hyper150 A 200 200 B 143 143 C

Dimension specification
D 185 185

170 170

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating Whispervent WVI150 220 - 240V 94 l/s, 340m/hr 46W 160 Pa 2750 RPM 38 dB(A) 80C IPX2 Hyper150 220 - 240V 89 l/s, 320m/hr 38W 135 Pa 2650 RPM 46 dB(A) 70C IPX2
B D A C
Dimensions

Performance - WhisperVent WVI150

Performance - Hyper150

36

72

108 144

180

216

252

288

324 360

36

72

108 144

180

216

252

288

324 360

70

90

70

90

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

45

Manrose CLASSIC IN-LINE AXIAL FANS


ID Models
Duct Size 100mm 100mm 125mm 125mm 150mm 150mm 230mm 230mm Model No. ID100S ID100T ID125S ID125T ID150S ID150T ID230S ID230T Switching Method Standard Timer Standard Timer Standard Timer Standard Timer Performance 23 l/s, 85m /hr 23 l/s, 85m3/hr 36 l/s, 130m3/hr 36 l/s, 130m /hr 87 l/s, 313m3/hr 87 l/s, 313m3/hr 152 l/s, 550m3/hr 152 l/s, 550m3/hr
3 3

Order Code FAN0012 FAN0013 FAN0060 FAN0061 FAN0090 FAN0091 FAN0405 FAN0406
ID100/125/150

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.
ID230

ECO IN-LINE AXIAL FANS


Duct Size 150mm Model No. ECO150S Switching Method Standard Performance 64 l/s, 230m3/hr Order Code FAN2078

BAL

LB

EA

IN

YEAR WARRANTY

GM

OT O R

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. High quality sleeve bearing motor. Supported by a 2 year warranty.

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery.

46

Technical data
Models ID100 ID125 ECO150 (white) ID150 ID230 (square model) A 130 150 187 187 286 B 155 155 153 153 286

Dimension specification
C 90 99 109 109 155 D 100 118 150 150 230 E 27 27 27 27 B E A D
Dimensions - ID Fans

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating ID100 220 - 240V 23 l/s, 85m/hr 20W 20 Pa 2400 RPM 41 dB(A) 50C IPX4 ID125 220 - 240V 20W 35 Pa 2000 RPM 41 dB(A) 50C IPX4 ECO150 220 - 240V 25W 50 Pa 2400 RPM 40 dB(A) 50C IPX4 ID150 220 - 240V 25W 60 Pa 2400 RPM 40 dB(A) 50C IPX4 ID230 220 - 240V 80W 50 Pa 1250 RPM 50 dB(A) 50C IPX4

36 l/s, 130m/hr 64 l/s, 230m/hr 87 l/s, 313m/hr 152 l/s, 550m/hr

Performance - ID100

Performance - ID125

Performance - ECO150

Performance - ID150

Performance - ID230

Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

47

Manrose CLASSIC IN-LINE CENTRIFUGAL FANS


CFD Models
Duct Size Model No. 100mm 100mm 125mm 125mm CFD200S CFD200T CFD225S CFD225T Switch Method Standard Timer Standard Timer Performance 31 l/s, 110m/hr 31 l/s, 110m/hr 39 l/s, 140m/hr 39 l/s, 140m/hr Order Code FAN0326 FAN0327 FAN2067 FAN2066
Manrose Classic In-Line CF 125mm Standard
OT O R

These high efficiency centrifugal fans are designed for use where longer duct runs are required. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty.

BAL

LB

EA

IN

YEAR WARRANTY

5
E
258 258

GM

Technical data
SPECIFICATION
Models
Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating

DIMENSION INFORMATION (mm)


CFD200
220 - 240V 31 l/s, 110m/hr 20W 120Pa 1400 RPM 45 dB(A) 50C IPX4

CFD225
220 - 240V 39 l/s, 140m/hr 20W 120Pa 1400 RPM 45 dB(A) 50C IPX4

Models
CFD200 CFD225

A
155 155

B
100 125

C
100 125

D
195 195

Performance - CFD200

Performance - CFD225

Dimensions - CFD200/CFD225

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. 3. Requires: permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery.

48

SIMX in-line CENTRIFUGAL 3 SPEED FANS


High Performance Models
Duct Size 150mm 200mm Model No. Performance @ Speed 3 3 Speed 3 Speed 115 l/s, 415m/hr 208 l/s, 750m/hr Order Code FAN0921 FAN0997

Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide high performance at your preset choice of speed. Supported by a 2 year warranty.
Please note: Can be used for supply or extract.

TECHNICAL DATA
Models 150mm 200mm A 340 340 B 150 200

DIMENSION INFORMATION (mm)


Dimensions

YEAR WARRANTY

C 154 280

D 50 50

E 75 50

TECHNICAL SPECIFICATION
Models Voltage/Freq (50hz) Fan Performance Speed 1 Fan Performance Speed 2 Fan Performance Speed 3 Fan Wattage (at high speed) Current (A) (at high speed) Fan Speed (at high speed) Sound Level* Ambient Temp
* dB(A) - measured 1m free field. Performance - 200mm 3 Speed Performance - 150mm 3 Speed

150mm 220 - 240V 65 l/s, 234m/hr 90 l/s, 324m/hr 124 l/s, 425m/hr 65W 0.36 2460 RPM 43 dB(A) 50C

200mm 220 - 240V 125 l/s, 450m/hr 170 l/s, 620m/hr 205 l/s, 740m/hr 110W 0.38 2700 RPM 56 dB(A) 60C

200mm 3 Speed Centrifugal Fan Curve


400

300

Pressure (Pa)

200

100

100

200

300

400

500

600

700

800

900

1000

Airflow (m3/hr)

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

49

SIMX IN-LINE FANS


Duct Size 100mm 125mm 150mm 200mm 250mm 315mm Model No MAN100 MAN125 MAN150 MAN200 MAN250 MAN315

High Performance Centrifugal Models


Performance 49 l/s, 176m3/hr 61 l/s, 220m /hr 115 l/s, 415m /hr 208 l/s, 750m3/hr 280 l/s, 1010m /hr 360 l/s, 1300m /hr
3 3 3 3

Order Code FAN0361 FAN0360 FAN0330 FAN0467 FAN0358 FAN0357


Simx 150mm In-Line Fan

Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide extremely high performance with a choice of sizes. Supported by a 2 year warranty.
Please note: Can be used for supply/extract.

YEAR WARRANTY

DIMENSION INFORMATION (mm)


Models
MAN100 MAN125 MAN150 MAN200 MAN250 MAN315

A
250 250 340 340 320 405

B
100 125 150 200 249 315

C
136 147 154 250 310 177

D
50 60 50 50 65 80

E
70 60 75 50 65 80

Dimensions

50

TECHNICAL DATA
Technical INFORMATION
Models Voltage/Freq (50hz) Fan Performance Fan Wattage Maximum Pressure Current (A) Fan Speed (min -1) Sound Level* Max Operating Temp
* dB(A) - measured 1m free field.

MAN100 220-240V 49 l/s, 176m/hr 32W 153 Pa 0.14 2500 RPM 38 dB(A) 60C

MAN125 220-240V 61 l/s, 220m/hr 31W 143 Pa 0.13 2490 RPM 38 dB(A) 60C

MAN150 220-240V 115 l/s, 415m/hr 65W 320 Pa 0.35 2350 RPM 50 dB(A) 50C

MAN200 220-240V 208 l/s, 750m/hr 110W 418 Pa 0.45 2520 RPM 56 dB(A) 60C

MAN250 220-240V 280 l/s, 1010m/hr 170W 500 Pa 0.76 2580 RPM 47 dB(A) 50C

MAN315 220-240V 360 l/s, 1300m/hr 200W 590 Pa 0.87 2410 RPM 57 dB(A) 45C

Performance - MAN100
Volume (m/h) 0 160 140 120 100 80 Static Pressure (Pa) Static Pressure (Pa) 60 40 20 0 0 10 20 30 40 50 Volume l/s 100mm 20 40 60 80 100 120 140 160 180

Performance - MAN125

Performance - MAN150

Volume (m/h) 0 160 140 120 100 80 60 40 20 0 0 10 20 30 40 50 60 70


Static Pressure (Pa)

Volume (m/h) 100 150 200 250


350 0 50 100 150 200 250 300 350 400

50

125mm

300 250 200 150 100 50 0 0 20 40 60

150mm

80

100

120

Volume l/s

Volume l/s

Performance - MAN200

Performance - MAN250

Performance - MAN315

Volume (m/h) 0 100 200 300 400 500 600 700 800 900 450 400 350 300 250 Static Pressure (Pa) 200 Static Pressure (Pa) 150 100 50 0 0 50 100 150 200 250 200mm 500 450 400 350 300 250

Volume (m/h) 0 200 400 600 800 1000 600

Volume (m/h) 0 200 400

600

800

1000

1200

1400

250mm

315mm 500 400 300 Static Pressure (Pa) 200 100 0 0 50 100 150 200 250 300 350 400 Volume l/s

200 150 100 50 0 0 50 100 150 200 250 300 Volume l/s

Volume l/s

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

51

SIMX IN-LINE CENTRIFUGAL FANS


WhisperVent Low Profile Models
Duct Size 150mm 150mm Model No WVILP150-1 WVILP150-3 Performance 124 l/s, 445m3/hr 118 l/s, 425m3/hr Order Code FAN0829 FAN0830

Suitable for a variety of domestic and commercial applications, this in-line centrifugal fan offers high performance with a low profile design to enable this unit to be installed in confined spaces. Supported by a 2 year warranty.

DIMENSION INFORMATION (mm)


Models
WhisperVent Low Profile

YEAR WARRANTY

A
313

B
168

C
148

D
340

E
218

Dimensions

52

TECHNICAL DATA

Technical specification
Single Phase Nom Watts 50 56 80 80 Nom Amps 0.22 0.24 0.36 0.36

Models FAN0830 FAN0830 FAN0830 FAN0829

Fan Speed 1 2 3 1

Fan Performance 65 l/s, 234m/hr 90 l/s, 324m/hr 124 l/s, 445m/hr 118 l/s, 425m/hr

Norm Fan Speed (RPM) 1440 1860 2460 2520

SOUND POWER LEVEL


Sound Power Levels Lw (A) Octave band centre frequency in Hz 63 FAN0830 - Speed 1 FAN0830 - Speed 2 FAN0830 - Speed 3 FAN0829 57 125 20 26 40 61 250 34 40 42 68 500 43 51 62 67 1k 43 51 64 65 2k 44 52 64 64 4k 40 45 59 59 8k 30 38 45 53 30 36 43 43

Model No

dB(A) @ 3m

Performance - FAN0829 & FAN0830

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

53

SIMX EXTERNAL WALL MOUNTED Fans


Extract MODELS
Duct Size 150mm 150mm 150mm Fan Type Axial Ctrfgl (190 Motor) Ctrfgl (220 Motor) Air Extract* Extract Extract Performance 73 l/s, 263m3/hr 109 l/s, 392m3/hr 133 l/s, 480m3/hr Order Code FAN2303 FAN2425 FAN2424

*Also available in a Supply Air option

Designed for use in residential and light commercial applications where a high performance, low noise solution isrequired. Specific applications include apartments where space is limited. Supported by a 2 year warranty.

150mm Ctrfgl (190 Motor)

SIMX EXTERNAL WALL Mounted Fans


3 Speed Extract MODELS
Duct Size 150mm 150mm Fan Type Ctrfgl (190 Motor) Ctrfgl (220 Motor) Air Extract Extract Performance (High Speed) 113 l/s, 408m3/hr 136 l/s, 493m3/hr Order Code FAN2423 FAN2426

YEAR WARRANTY

Designed for use in residential and light commercial applications where a high performance, low noise solution isrequired. Three speed models enable further flexibility in a variety of applications. Specific applications include apartments where space is limited. Supported by a 2 year warranty.

Wall mounted with measurements

Fan Assembly - Line Drawing

369mm 369mm

305mm 110mm 110mm

305mm

Switching Options 1. Electrical connection must be made internally (Junction Box is only suitable for internal use). NOTE: All fan flow rates quoted are free air delivery.

54

TECHNICAL DATA
PERFORMANCE DATA
Fan Performance m/hr 263 392 480 l/s 73 109 133

Order Code FAN2303 FAN2425 FAN2424

Motor Size Description (mm) 150 150 150 Axial Centrifugal 190 Motor (1 Speed) Centrifugal 220 Motor (1 Speed)

Watts @ 230V 48 65 96

Amps 0.29 0.28 0.42

Static Sound Level Pressure (Pa) (dB(A) @ 3m) 80 280 380 48 60 61

FAN2423

150

Centrifugal 190 Motor (3 Speed) High Speed Medium Speed Low Speed Centrifugal 220 Motor (3 Speed) High Speed Medium Speed Low Speed 493 408 340 136 113 94 96 69 60 0.42 0.34 0.31 380 340 280 61 56 50 408 340 277 113 94 77 65 57 55 0.28 0.25 0.24 280 250 200 60 56 46

FAN2426

150

400 350 300 250


Pressure (Pa)

Icon Key
FAN2303 150mm AXIAL FAN2425 150mm CENTRIFUGAL (190 Motor) FAN2424 150mm CENTRIFUGAL (220 Motor)
0 50
Airflow (L/s)

200 150 100 50 0 100 150

400 350 300 250


Pressure (Pa)

200 150 100 50 0 0 50


Airflow (L/s)

FAN2423 150mm 3 SPEED CENTRIFUGAL (190 Motor) FAN2426 150mm 3 SPEED CENTRIFUGAL (220 Motor)
100 150

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

55

THRU-ROOF MOUNTED FANS


Thru Roof Fan Cowl Models
Duct Size 150mm 150mm 150mm 150mm 150mm Fan Type Ctrfgl Ctrfgl 3-spd Axial - Whisper Axial Axial - Whisper Air Extract Extract Extract Extract Supply Performance 153 l/s, 550m hr 153 l/s, 550m hr 89 l/s, 320m /hr 75 l/s, 270m /hr 75 l/s, 270m3/hr
3 3 3 3

Order Code FAN0529 FAN1002 FAN1009 FAN0531 FAN0533


150mm Axial - Whisper

High quality aluminium cowl construction, with fan incorporated, for longevity of operation. Supported by a 2 year warranty.

With Flashing & HDPE Tube


Duct Size 150mm 150mm 150mm 150mm 150mm 150mm 150mm Fan Type Ctrfgl Ctrfgl 3-spd Axial - Whisper Axial Axial H/D Axial H/D Ctrfgl Air Extract Extract Extract Extract Supply Extract Extract Performance 153 l/s, 550m3hr 153 l/s, 550m hr 89 l/s, 320m3/hr 75 l/s, 270m /hr 75 l/s, 270m3/hr 75 l/s, 270m /hr 153 l/s, 550m hr
3 3 3 3

Order Code FAN0530 FAN0967 FAN1060 FAN0532 FAN0534 FAN0739 FAN0740


150mm Axial - Whisper

YEAR WARRANTY

H/D = Heavy Duty cowl used in these kits.

High quality aluminium cowl construction, with fan incorporated for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty.

Thru Roof Fan System Models


Duct Size 150mm 150mm Description Ultra Hyper Fan Type Ctrfgl Hyper Performance* 153 l/s, 550m3/hr 75 l/s, 270m /hr
3

Order Code FAN0535 DCT0189

High quality aluminium cowl construction, with fan incorporated, for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty.
150mm Hyper Fan System

Connection 1. Electrical connection can be made inside or outside the roof space. * NOTE: All fan flow rates quoted are motor performance in free air.

YEAR WARRANTY

56

TECHNICAL DATA
Models FAN0529 - FAN1002 FAN1009 FAN0531- FAN0533 FAN0530 - FAN0967 FAN1060 FAN0532 - FAN0534 FAN0739 - FAN0740 A 275 275 275 275 275 275 275 B 170 170 170 170 170 170 170

Dimension information (mm)


C 500 500 500 500
C
Dimensions - Thru Roof Fans

A B

TECHNICAL SPECIFICATION
Models FAN0529 FAN0530 FAN0740 220-240VAC Centrifugal 153 l/s, 550m /hr 58W 320 Pa 2500 RPM 62 dB(A) -25 - +50C IPX4
3

FAN1002 FAN0967 220-240VAC Centrifugal 153 l/s, 550m /hr 58W 320 Pa 2500 RPM 62 dB(A) -25 - +50C IPX4
3

FAN0531 FAN0532 FAN0739 220-240VAC Axial 75 l/s, 270m /hr 44W 80 Pa 2850 RPM 55 dB(A) -20 - +80C IPX2
3

FAN0533 FAN0534 220-240VAC Axial 75 l/s, 270m /hr 44W 130 Pa 2850 RPM 55 dB(A) -20 - +80C IPX2
3

FAN1009 FAN1060 220-240VAC Axial - Whisper 89 l/s, 320m3/hr 46W 130 Pa 2750 RPM 38 dB(A) -20 - +80C IPX2

Supply Voltage Fan Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level @ 1m Operating Temp IP Rating

Performance - FAN0529/FAN0530/FAN0740

Performance - FAN0531/FAN0532/FAN0739

350 300 250 200 150 100 50 0 0 50 100 Airow (L/s) 150 200

90 80 70 60 Pressure (Pa) 50 40 30 20 10 0 0 20 40 60 Airow (L/s) 80 100 120

FAN0530 / FAN0555 Performance - FAN0533/FAN0534

Pressure (Pa)

FAN0532 / FAN0553

Performance - FAN1009/FAN1060

90 80 70 60 50 40 30 20 10 0 0 20 40 60 Airow (L/s) 80 100 120

160 140 120 100 80 60 40 20 0 0 50 Airow (L/s) 100 150

FAN0532 / FAN0553

FAN1009 / FAN1060

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

Pressure (Pa)

Pressure (Pa)

57

Manrose PRO-SERIES HAND DRYERS


PUBLIC AREAS/HEAVY USAGE APPLICATIONS
Designed to provide a cost effective alternative to conventional Hand Dryers. Providing a rapid drying time of 10 seconds, almost half that of the competitors products, thus reducing washroom time.

NEW
Heavy Usage Hand Dryers

Model No. MAN/E-88AE MAN/E-88AEBC

Cover

Colour

Switching Performance Method Auto Auto 56 l/s, 200m3/hr 56 l/s, 200m3/hr

Order Code FAN2287 FAN2286

Stainless White Steel Stainless Satin Steel

70% energy savings. Tamper Proof Technology. Suitable for use in public areas for heavy usage. Supported by a 5 year warranty.
Manrose Hand Dryer - MAN/E-88AE

Manrose CLASSIC HAND DRYERS


PUBLIC AREAS/HEAVY USAGE APPLICATIONS
Switching Performance Method Auto Auto Auto Auto Auto 56 l/s, 200m3/hr 108 l/s, 388m3/hr 108 l/s, 388m3/hr 108 l/s, 388m3/hr 130 l/s, 470m3/hr

Model No. MAN/M-88A MAN/A-89 MAN/A-89S MAN/A-89B MAN/E-88A

Cover ABS Thermoplastic 3mm Aluminium 3mm Aluminium 3mm Aluminium Porcelain Enamel 2mm Steel

Colour White White Silver Black White

Order Code FAN2902 FAN4396 FAN4395 FAN4397 FAN2903


Manrose Hand Dryer - MAN/E-88AEBC

These models are suitable for use in public areas such as lavatories, factories, schools, railways and motorway service stations and are designed for heavy usage and unsupervised areas. Supported by a 2 year warranty.

Manrose MAN/M-88A

Manrose MAN/A-89

Colour Options available: White, Silver and Black

Manrose MAN/E-88A

YEAR WARRANTY

58

TECHNICAL DATA
Dimension information Dimension SPECIFICATION (mm) - Hand dryers
Model MAN/E-88AE MAN/E-88AEBC MAN/M-88A MAN/A-89 MAN/E-88A A 201 201 225 225 284 B 277 277 275 275 248 C 175 175 160 160 202

TECHNICAL SPECIFICATION - Pro-Series


Dimensions - MAN/E-88AE Models, MAN/E-88AEBC

Models Power Cover Colour Fan Performance Operation Heater Element Power Dry Time Sound Level Weight

MAN/E-88AE 220 - 240V Stainless Steel White

MAN/E-88AEBC 220 - 240V Stainless Steel Stainless Satin Steel


A

56 l/s, 200m /hr


No touch infra-red detection 450 - 900W adjustable 1.6kW @ 240V 10 secs 74 dB(A) 7.0kg

56 l/s, 200m3/hr
No touch infra-red detection 450 - 900W adjustable 1.6kW @ 240V 10 secs 74 dB(A) 7.0kg

Dimensions - MAN/M-88A, A-89, A-89S A-89B

TECHNICAL SPECIFICATION - CLASSIC


B

Models Power Cover Colour

MAN/M-88A 220 - 240V

MAN/A-89 220 - 240V

MAN/E-88A 220 - 240V Steel 2mm Porcelain Enamel White 130 l/s, 470m/hr No touch infra-red detection 2.4kW @ 240V 70 dB(A) 7.5kg
Depth

C
Depth

ABS Thermoplastic 3mm Aluminium White White, Silver, Black 108 l/s, 388m3/hr No touch infra-red detection 2.0kW @ 240V 69 dB(A) 4.7kg

Dimensions - MAN/E-88A

Fan Performance 56 l/s, 200m/hr Operation Power Sound Level Weight No touch infra-red detection 1.5kW @ 240V 54 dB(A) 3.3kg

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

59

SPECIALISED FANS
Frame Fan Model
Duct Size 120mm 150mm Model No. Frame Fan Frame Fan Switching Method Standard Standard Performance Order Code

38 l/s, 138m/hr FAN0397 89 l/s, 320m/hr FAN1043

This frame fan is designed for use in computer rooms or applications where the introduction of cool air is required for small enclosed spaces. The ball bearing motor prolongs the life of the motor. Supported by a 2 year warranty.

Frame Fan 125mm

ACCESSORIES
Duct Size 120mm 120mm 150mm Description Finger Guard for FAN0397 - Metal Filter Guard for FAN0397 Finger Guard for FAN1043 Order Code FAN0412 FAN0413 FAN0841

TECHNICAL DATA
Technical information
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating Frame Fan 125 220 - 240V 38 l/s, 138m/hr 15W 62Pa 2650 RPM 43 dB(A) 80C IPX4 Frame Fan 150 220 - 240V 89 l/s, 320m/hr 38W 135Pa 2650 RPM 46 dB(A) 70C IPX2 Models Frame Fan 125 Frame Fan 150 A 120 172 B 120 150 C

YEAR WARRANTY

2
D

Dimension SPECIFICATION

105 40 160 51

Performance - 125mm Frame Fan

Performance - 150mm Frame Fan

Dimensions - Frame Fan

D
36 72 108 144 180 216 252 288 324 360

A C

70

90

NOTE: All fan flow rates quoted are free air delivery.

60

Manrose CLASSIC DC SPECIALISED FANS


12/24V Extract-a-lite Models
Duct Size 100mm 100mm 100mm 100mm 100mm 100mm Switching Colour Method Standard Standard Standard Standard Standard Standard White Gold Chrome White Gold Chrome

Model No. BSL112W BSL112G BSL112C BSL124W BSL124G BSL124C

Performance 18 l/s, 64m3/hr 18 l/s, 64m /hr 18 l/s, 64m3/hr 18 l/s, 64m /hr 18 l/s, 64m3/hr 18 l/s, 64m /hr
3 3 3

Order Code FAN0625 FAN0690 FAN0691 FAN0626 FAN0686 FAN0685

A compact extractor fan combined with an integral halogen light. Designed for installation in galleys, showers and toilets, ideal for marine and other leisure applications. Long life computer motor which will run continuously, only 2.8 watts. Supported by a 2 year warranty.
Dimensions - DC Extract-a-lite

ACCESSORIES - Extract-a-lite Cowl


Duct Size 100mm Description Extract-a-lite cowl Order Code DCT1097

E B

External cowl suitable for use in marine and non-marine applications

TECHNICAL DATA
Dimension information
Models BSL112 BSL124 A 140 140 B 90 90 C 52 52 D 12 10 E 98 98 F 38 38
A

TECHNICAL SPECIFICATION
Models Power Fan Performance Fan Wattage Maximum Pressure Fan Speed Sound Level Max. Operating Temp IP Rating BSL112 12 VDC 18 l/s, 64m/hr 45W 125 Pa 1400 RPM 45 dB(A) 40C IPX4 BSL124 24 VDC 18 l/s, 64m/hr 45W 125 Pa 1400 RPM 45 dB(A) 40C IPX4

Performance - DC Extract-a-lite

YEAR WARRANTY

Switching options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

61

FAN ACCESSORIES
Fan timer
Model No. Time Air Description 7 Minute Fixed Timer (suits fans 20W-200W) Order Code FAN0372

A fixed fan timer that will automatically switch the appliance off after approximately 7 minutes. Description
Fully Adjustable Run-On Fan Timer

Time Air - Fan Timer

Order Code FAN2444

Timing Switch 1 Sec to 90 Mins. Adjustable Run Timer & Start Delay.

Transformers
Model No. ACTO TE0060 Description Electronic Transformer 12VAC 50kHz Order Code FAN2101

Fully adjustable Run-On Fan Timer

This transformer must only be used with 12V lighting installations. Supports lamp wattages from 20W - 60W. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers. Description SELV Isolating Transformer 12VAC Order Code FAN2402

Electronic Transformer

Model No. TM 50-2-07

SELV isolating transformer is required for all low voltage fan installations. Can be used with low voltage 12V lighting. Supports lamp wattages from 20W - 50W. An iron core transformer. Thermally stable and shatter-proof plastic casings. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers.

Humidistat Controller
Model No. 1360
62

Description Humidistat Controller

Order Code FAN0963

Designed to operate the fan when the relative humidity (RH) reaches a preset level. Fits a double pattress. This unit is adjustable between 20 - 90% RH.

Humidistat Controller

FAN ACCESSORIES
ULTECON Thermostats
Model No. TA01 TD01 TD02 TD03 Description Analogue Thermostat Digital Thermostat Digital 2 Speed Thermostat Digital 3 Speed Thermostat Order Code FAN0153 FAN0981 FAN0982 FAN0983

High quality, easy to use thermostats. Dual output switching for both cooling and heating situations. Electronic temperature sensor. Included in Heat Trans systems.

TD03 Digital 3 Speed Thermostat

Speed Controllers
Model No. 1348 1349 1350 PDL625F Description For XF/XP/WF 230/300 Fans* For XF/XP/WF 230/300 Fans* For any XF/XP/WF 230/300 Fans General Purpose up to 500W Switching Method 2 Spd + Reverse Adjust + Reverse Adjustable On-Off + Adjust Order Code FAN0155 FAN0156 FAN0157 FAN2104
PDL625F General Purpose

A range of speed controllers with variable or 2 speed and reversible options. Models 1348-1350: Electrical load must be between 20 and 200 watts. FAN0154 - Single pattress mounting block for FAN0155/0156/0157.
*Not suitable for manual pull cord model fans.

ULTECON Speed Controller


Model No. SPC05 Description Ultecon 5 Speed Fan Controller Input Output Current Power 1A 100W Order Code FAN1096

5 speed fan selection - manual or external control. Enclosure can be wall mounted or free standing. On/Off switch.

Ulecon 5 Speed Fan Controller

Fan Mounting Brackets


Duct Size 100-200mm 250-315mm Description Fan Mounting Bracket for 100 - 200mm Fan Mounting Bracket for 250 - 315mm Order Code FAN0015 FAN0016

These adjustable fan mounting brackets, designed for use with the centrifugal fans. Supplied in pairs.

100-200mm Fan Mounting Bracket

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

63

AUSTRALIAN DUCT
STANDARDS
We strive to provide the best possible flexible duct at a competitive and fair price, that complies to all necessary Standards. Australian Standards (AS) 4254 & (AS) 4508 Most Commonly Asked Questions: Q. What is AS 4254? A. Australian Duct Fire Standard (AS) 4254. This standard was developed to ensure public safety, that the product tested will not support combustion and will function as designed for its service life. All heating systems in Australia ignited from a flame source and all commercial class 2 to 9 buildings must FULLY COMPLY with AS 4254. In Victoria all Ducting Installations must be fire rated to AS 4254. Q. How do I know if the duct passes AS4254? A. If a flexible duct passes AS 4254 it has been tested to and passed eleven difficult tests. Ensure the product in the test has been tested in its composite form, just the way you buy it, i.e. duct core, insulation blanket and outerjacket. Each test should state product name and its componentry make-up. If you cannot be supplied test reports to cover each of the eleven tests or there is a reluctance from duct manufacturers/duct assemblers to produce any or all of these reports it is likely that the duct DOES NOT comply to AS 4254. Manufacturers/duct assemblers are under no obligation to produce AS 4254 compliantproduct. If you install flexible duct that does not comply, on a gas fired heating system then YOU ARE IN BREACH OF AS 4254, not the manufacturer/duct assemblers. Ducting that does not comply to AS 4254 may be used on Reverse Cycle and Evaporative Systems except in Victoria. The onus is on you to choose and use compliant product. Q. What is AS 4508? A. Australian insulation Standard (AS) 4508. Due to poor quality insulation being used on ducting, AS 4508 was developed to create minimum acceptable thermal values for ducting, helping to reduce the greenhouse effect and lower running costs. This standard specifies how insulation on the ducting must be tested so an overall thermal or R value can be achieved consistently throughout all the duct in thesystem. Q. How do I know if the insulation meets the requirements of AS 4508? A. Ask to see the test report from your duct manufacturer /duct assembler that shows that the insulation had been tested to and complies with AS 4508. To achieve a thermal rating of R0.6 you must use a minimum of 250 g/ m polyfibre insulation at 40mm thick. To achieve an R1.0 you must use a minimum of 450 gram/square metre polyfibre insulation at 70mm thick. Fibreglass thermal values remain the same as they have for years, 25mm=R0.6 and 40mm=R1.0. There will be variations depending on the manufacturer of the insulation but in general the above rules apply.

Compliance to AS/NZ 1530 Part 3 Requirements are: Internal Surface: External Surface: Spread of flame not >0 Smoke Developed not >3 Spread of flame not >7 Smoke developed not >5

AS/NZS 1530 Part 3 This is the Australian standard 1530, method for fire tests on building materials components andstructures. Simultaneous determination of ignitability, flame propagation, heat release and smoke release

AS 4254 comprises of the tests listed below:


(AS) 1530 part 3 - radiant burn test Underwriters Laboratories (U.L) 181 part 9 - flaming burn test (U.L) 181 part 11 - mould growth test (U.L) 181 part 12.2 - low temperature test (U.L) 181 part 12.3 - high temperature test (U.L) 181 part 13 - puncture test (U.L) 181 part 14 - static load test (U.L) 181 part 15 - impact test (U.L) 181 part 17 - positive & negative pressure test (U.L) 181 part 18 - collapse test (U.L) 181 part 19 - tension test

64

DUCTING INSTALLATION & USAGE


The layout of flexible duct, the number of bends, the sharpness of the bend and the amount of sag allowed between support joints will have serious effects on system performance due to the increased resistance to airflow eachintroduces. Use the minimum length of flexible duct to make connections. It is not recommended that excess length of ducts be installed to allow for possible future relocations of air terminal devices. Avoid installation where exposure to direct sunlight can occur e.g: skylight. Grilles and diffusers need to be supported independently of the flexible duct. Repair torn or damaged vapour barrier/jacket with duct tape listed and labelled to Standard AS4254. If internal core is penetrated, replace flexible duct or treat as a join.

Right Setup

Install duct fully extended, do not install in the compressed state or use excess lengths. This will noticeably increase friction losses.

Wrong Setup

Avoid bending ducts across sharp corners or incidental contact with metal fixtures, pipes orconduits. Flexible ducts shall be installed with a bend radius to duct diameter ratio in accordance with the following info on the next page.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

65

DUCTING INSTALLATION & USAGE


Duct velocity R/D ratio centerline radius to duct diameter:

Up to 5m/s x 0.6 5m/s x 1.0 Above 8m/s x 1.5

e.g. Assuming duct velocity of 8m/s

Steam Pipes

Wrong Setup

Do not install near hot equipment (e.g. heaters boilers, steam pipes etc.) that is above the recommended flexible duct use temperature.

66

AIR DUCTS
01

Non-metallic with Plain Ends. After desired length is determined, cut completely around and through duct with knife or scissors. Cut wire with wire cutters. Fold back duct jacket and insulation.

02

Slide at least 1 (25mm) of core over the fitting up to the bead. Seal the core to collar with at least two wraps of duct tape. Secure connection with cable ties placed over the core and duct tape.

03

Pull jacket and insulation back over core. Tape jacket with at least 2 wraps of duct tape ensuring end of the outer jacket is secured to the spigot. Cable ties may be used in place of or in combination with the duct tape.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

67

JOINS
01

Fold back duct jacket and insulation from core. Butt two cores together on a 4 (100mm) length metal sleeve or polymer sleeve.

02

Tape cores together with at least 2 wraps of duct tape. Connection can be secured with 2 cable ties placed over the taped core ends.

03

Pull jacket and insulation back over cores. Tape jackets together with at least 2 wraps of duct tape.

68

SUPPORTING FLEXIBLE DUCT


01

Flexible duct shall be supported at intervals, no greater distance than 1.5m. Maximum permissible sag is 60mm per metre of spacing between supports. A connection to rigid duct or equipment shall be considered a support joint.
SAG 60mm

Long horizontal duct runs with sharp bends shall have additional supports before and after the bend approximately one duct diameter from the centreline of the bend. Recommend Hanging Straps DCT0808.

02

Hanger or saddle material in contact with the flexible duct shall be of sufficient width to prevent any restriction of the internal diameter of the duct when the weight of the supported section rests on the hanger or saddle material. In no case will the material contacting the flexible duct be less than 40mm wide.
40mm min

40mm

Wire

03

Factory installed suspension systems integral to the flexible duct is an acceptable hanging method.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

69

SUPPORTING
FLEXIBLE DUCT

Flexible ducts may rest on ceiling joists or truss supports. Maximum spacing between supports shall not exceed 1.5m.

Ceiling Joist

(1.8m) Max

Vertically installed duct shall be stabilised by support straps at a max of 1.8m.

Support the duct between a metal connection and bend by allowing the duct to extend straight for 100mm before making the bend. This will avoid possible damage of the flexible duct by the edge of the metal collar. NOTE: Upon completion of installation, please test in accordance with 2.8.2 of standard AS4254. NOTE: factory-made air ducts may not be used for vertical risers in air duct systems serving more than two stories.

70

Technical Data
FLEXIBLE DUCTING Flexible Ducting Friction FRICTION LOSS GRAPH Loss Graph

Technical Data
Flexible Ducting Friction Loss Graph

Technical Data
Flexible Ducting Friction Loss Graph
Diameter of Duct in mm

Air Volume m3/h

40

Friction Loss (Paper metre)

Fax: (09) 259 1661 Email: sales@securimax.co.nz Website: www.securimax.co.nz

40

Fax: (09) 259 1661 Email: sales@securimax.co.nz Website: www.securimax.co.nz

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au Fax: (09) 259 1661 Email: sales@securimax.co.nz Website: www.securimax.co.nz

(m3/h / 3.6 = l/s)

Air Volume m3/h (m3/h 3.6 = l/s) 3/h / 3.6 = l/s) (m 3/h (m / 3.6 = l/s)

3/h 3/h Air Volume m Volume m Air

Friction Loss (Pa per metre) metre) per Loss (Pa Friction Friction Loss (Pa per metre)
71

ALUDUCT/COMFLEX FLEXIBLE DUCTING

MANROSE ALUDUCT Diameter (mm) 100 Length (m) 1 3 6 1 3 6 1 3 6 3 6 3 6 3 6 3 6 3 6 Order Code DCT0357 DCT0328 DCT0358 DCT0329 DCT0359 DCT0330 DCT0331 DCT0332

COMFLEX NUDE Order Code

COMFLEX INSULATED Order Code

DCT0367 DCT0409 DCT0368 DCT0410 DCT0369 DCT0411 DCT0377 DCT0412 DCT0370 DCT0413 DCT0380 DCT0414 DCT0415 DCT0416 DCT0417 DCT0418 DCT0088 DCT0399 DCT0089 DCT0343 DCT0400 DCT0344 DCT0401 DCT0402 DCT0403 DCT0404 DCT0405 DCT0406

Nude

125

150

200 250 300 350 400

Insulated

Fully complies to AS 1530 Pt3. DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated, spring steel wire helix. DUCT SLEEVE: Fire retardant 75m black low density polyethylene and UV stabilised. DUCT INSULATION: AS4508 Polyester R0.6. TEMPERATURE RANGE: Maximum: +80C, Minimum: -10C. COLOUR: Silver with black sleeve.

Colour Code Label Guide: Ducting

Black 150mm (6)

Blue 250mm (10)

Red 350mm (14)

Yellow 200mm (8)

White 300mm (12)

Grey 400mm (16)

Note All 1 metre lengths are packed in bags with header cards, 3 metre aluduct duct is supplied boxed and all other items are supplied in colour coded bags. No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure. Products with the order code shown are generally ex. stock lines - other products are available to order. Should you have an ongoing requirement for an item that is not a standard stock line - PLEASE discuss with us and we will review stocking the item for you.

72

UNILOK

FR1 Acoustic Ducting


INSULATED R0.6 Diameter (mm) 100 125 150 200 Length (m) 3 6 3 6 3 6 3 6 Order Code DCT1216 DCT1164 DCT1224 DCT0633 DCT0634 DCT0635 DCT0636 INSULATED R1.0 Order Code DCT1268 DCT1176 DCT0833 DCT0834 DCT0835 DCT0836
Acoustic Insulated R0.6 (40mm)

UNILOK FR1 Acoustic Ducting is a flexible duct manufactured tough & whisper quiet for consumer & installer peace of mind. Unlike other types of flexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and correct diameter, even in the tightest bends. Due to its steel rib, it is not prone to glue failure or fatigue (sagging or ovalisation) from vibration with age like plastic ribbed or non-ribbed glued duct.

Fully complies to AS1530 Pt3. Designed for low noise air transfer. Fully flexible same mechanical construction as standard Unilok ducting. DUCT CORE: A UV resilient fire retardant 100m black low density polyethylene perforated material mechanically locked into an outer metal helix with a copper coated spring steel wire. DUCT SLEEVE: Fire retardant 75m black low density polyethylene and UV stabilised. DUCT INSULATION R0.6: AS4508 Polyester R0.6. DUCT INSULATION R1.0: AS4508 Polyester R1.0. TEMPERATURE RANGE: Maximum: +80C, Minimum: -10C.

Insertion Loss, dB Octive Band Centre Frequency Sample 150mm UNILOK FR1 R0.6 AI 300mm UNILOK FR1 R0.6 AI 400mm UNILOK FR1 R0.6 AI 125 35.5 33.3 36.1 250 39.2 35.9 30.0 500 36.0 27.3 20.6 1000 30.3 31.0 27.2 2000 29.8 28.1 26.0 4000 31.5 17.0 12.7 8000 22.5 12.2 10.5

Colour Code Label Guide: Ducting

Black 150mm (6)

Yellow 200mm (8)

Note 1. Products with the order code shown are generally ex. stock lines - other products are available to order 2. Should you have an ongoing requirement for an item that is not a standard stock line PLEASE discuss with us and we will review stocking the item for you.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

73

Manrose PVC
Flexible Ducting
Diameter (mm) 100 125 150 Length (m) 1 3 1 4 1 5

Pack Header Carded Boxed Header Carded Boxed Header Carded Boxed

Order Code DCT0936 DCT0336 DCT0937 DCT0337 DCT0938 DCT0338

150mm PVC Flexible Ducting

P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry. It doesnt rot, is non-collapsing, is fire resistant, has an operating temperature of +6 to +50 and is available in a range of sizes from 100mm to 150mm. Fully complies to AS1530 Building code. DUCT CORE: Spiral wire reinforced PVC film construction. Non-collapsing/non-rotting. Vapour-proof. Fire retardant. TEMPERATURE RANGE: Maximum: +50C : Minimum: 6C. COLOUR: White PVC.

SEMIDUCT Semi Rigid


Ducting
Diameter (mm) 100 125 150 200 250 300 350 400 Length (m) 1.5 3 1.5 3 1.5 3 3 3 3 3 3 Pack Boxed Loose Boxed Loose Boxed Loose Loose Loose Loose Loose Loose Order Code DCT0333 DCT0114 DCT0334 DCT0115 DCT0335 DCT0116 DCT0117 DCT0118 DCT0119 DCT0120 DCT0477

Semiduct Semi Rigid Ducting

SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, flexible but strong corrugated aluminium duct. It is spiral wound with a unique interlocked and knotted continuous seam. It is self supporting over longer lengths and generally only needs fittings or mechanics at each end for support.
74

Fully complies to the Building Code of Australia. DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam. Holds shape, self supporting. TEMPERATURE RANGE: Maximum: +250C, Minimum: -30C. COLOUR: Silver.

Manrose
SOLID TUBE Solid Tube - Rigid Steel
Diameter Length (mm) (m) 100 100 125 125 125 150 150 150 0.9 0.9 0.9 0.9 1.2 0.9 0.9 1.2 Finish Galvanised White Galvanised White Galvanised Galvanised White Galvanised Order Code DCT0151 DCT0145 DCT0152 DCT0146 DCT0953 DCT0153 DCT0147 DCT0954
Acoustic Insulated R0.6 (40mm)

Solid Tube - White Plastic


Diameter (mm) 100 125 150 Length (m) 0.9 0.9 0.9 Finish PVC PVC PVC Order Code DCT1424 DCT1425 DCT1426

Manrose Low Profile Ducting


Flat Channel
Dimension (mm) 110 x 54 204 x 60 220 x 90 300 x 25 Equivalent Size (mm) 100 125 150 100 Length (m) 1.5 1.5 1.5 1.5 Order Code DCT0013 DCT0519 DCT1443 DCT1460 204mm x 60mm: Suitable for ducting of kitchen cooker hoods with 100, 125 or 150mm round exhaust spigots. The flat channel cross section of 12240mm2 increases efficiency. High Performance 220mm x 90mm: Suitable for applications requiring high performance extraction or supply. The flat channel cross section of 19800mm2 makes it highly efficient and higher extraction rates are achieved. Flat Ducting 300mm x 25mm: Suitable for applications where space is very limited.
204 x 60 Low Profile Ducting Flat channel

Low profile ducting enables it to be concealed when installed along the top of wall units. It can also be fitted in ceiling voids and cavity walls, providing versatility whilst remaining unobtrusive. All Manrose system parts and channels are made from flame-retardant material. Four Low Profile System Sizes 110mm x 54mm: Suitable for applications requiring low extraction rates, such as ventilation of domestic bathrooms and toilets. With a 5940mm2 cross-section it provides efficient ducting for short, straight runs connecting to a 100mm roundspigot.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

75

Manrose LOW PROFILE


DUCT FITTINGS

Low Profile Connectors


Dimension (mm) 110 x 54 204 x 60 220 x 90 300 x 25 Order Code DCT0014 DCT0520 DCT1442 DCT1459

Horizontal 90 Bends
Dimension (mm) 110 x 54 204 x 60 220 x 90 300 x 25 Order Code DCT0125 DCT0524 DCT1448 DCT2097

Vertical 90 Bends
Dimension (mm) 110 x 54 204 x 60 220 x 90 300 x 25 Order Code DCT0126 DCT0525 DCT1447 DCT2099

Horizontal 45 Bend
Dimension (mm) 300 x 25 Order Code DCT2098

Vertical 45 Bend
Dimension (mm) 300 x 25 Order Code DCT1455

Horizontal T-Piece Connectors


Dimension (mm) 110 x 54 204 x 60 Order Code DCT1479 DCT1114

Short Adapter Rectangular: Round


Dimension (mm) 110 x 54 : 100 110 x 54 : 100 (m) = Male (f) = Female Order Code DCT0127 (f) DCT0131 (m)

Adapters Rectangular: Round


Dimension (mm) 110 x 54 : 100 204 x 60 : 125 220 x 90 : 150 300 x 25 : 100 Order Code DCT1482 DCT0526 DCT1446 DCT1461

Flat Channel Reducers


Dimension (mm) 110 x 54:204 x 60 204 x 60:220 x 90 300 x 25:204 x 60 Order Code DCT0136 DCT1452 DCT1456

Designed to fit 204 x 60mm flat channel or airbrick.

76

Elbow Bends 100mm


Dimension (mm) 110 x 54 110 x 54 204 x 60 220 x 90 300 x 25 Order Code DCT0124 (m) DCT0015 (f) DCT0521 DCT1444 DCT2095

Elbow Bends 125mm


Dimension (mm) 204 x 60 220 x 90 300 x 25 Order Code DCT0522 DCT1440* DCT2096

Elbow Bends 150mm


Dimension (mm) 204 x 60 220 x 90 Order Code DCT0523 DCT1441*

*Rotating offset spigot *Rotating offset spigot

(m) = Male (f) = Female

Horizontal Bend Adjustable


Dimension (mm) 204 x 60 Order Code DCT1480

Horizontal Airbrick Insert


Dimension (mm) 204 x 60 Order Code DCT0137

Vertical Airbrick Insert


Dimension (mm) 204 x 60 Order Code DCT1414

Duct connection requires the following Reducer or Connector: 110 x 54: requires: DCT0136 204 x 60: requires: DCT0520

Comes complete with duct connector DCT0520.

Double Airbrick
Dimension (mm) 232 x 138 Order Code DCT1450

Double Airbrick Adaptor


Dimension (mm) 220 x 90:232 x 138 Order Code DCT1451

Double Airbrick Reducer


Dimension (mm) 235 x 140 Order Code DCT1453

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

77

Manrose LOW PROFILE


DUCT FITTINGS

Wall/Ceiling Plates Round


Dimension (mm) 155 x 155 : 104 170 x 170 : 130 200 x 200 : 160 Order Code DCT0148 DCT0149 DCT0150

Wall/Ceiling Plates Rectangular


Dimension (mm) 155 x 155 : 110 x 55 264 x 118 : 206 x 60 Order Code DCT0016 DCT0528

External Tube Grille


Diameter (mm) 100 Order Code DCT2206

Designed to fit directly into round solid tube, for systems ducted straight through an external wall.

External Louvred Grilles


Diameter (mm) 100 125 150 Order Code DCT2200 DCT2201 DCT2202

Flat Channel Clips


*2 clips are required to secure ducting.

Dimension (mm) 110 x 54 (A) 204 x 60 (A) 220 x 90 (B) 300 x 25 (B)

Order Code DCT0134 DCT0527 DCT1445* DCT1458*

Manrose In-Line
Backdraught Shutters
PVC Duct Size (mm) 100 125 150 200 Order Code FAN0213 DCT0036 DCT0511 DCT2092
150mm PVC In-Line Backdraught Shutter

METAL Order Code

78

BRANCH TAKE OFF


(B.T.O)
POLY Duct Size (mm) 100-100-100 125-125-125 150-150-150 200-150-150 200-200-150 200-200-200 INSULATED

Order Code Order Code DCT1439 DCT1501 DCT0091 DCT0719 DCT0460 DCT0461 DCT0875 DCT0876 DCT0877 DCT0878
200-200-200 Branch Take Off

Manufactured from HDPE. UV stabilised, Heavy duty, robust. Smooth internal lines, no sharp edges. Positive lock duct tabs. Insulation meets AS 1530 part 3. Insulation material LDPE, thickness 5mm.

REDUCERS
PVC Duct Size (mm) 125-100 150-100 150-125 Order Code DCT2067 DCT2122 DCT2066
PVC Plastic

Duct Joiners/Spigots
PVC Duct Size (mm) 100 125 150 200 250 DCT0723 DCT0724 DCT0725 Order Code DCT0159 DCT0037 DCT0059 DCT0071 DCT0339 DCT0935 DCT0939 DCT0940
Metal Short Metal Plate Spigots

METAL LONG Order Code

METAL SHORT Order Code

METAL PLATE SPIGOTS Order Code


Metal Long PVC Plastic

Note 1. Products with the order code showing are generally ex. stock lines - other products are available to order. 2. Combinations of sizes which are not ex. stock can be made up using a suitable body and the relevant reducers and fitting joiners poly. 3. Nude combination fittings will be supplied in component form. We do NOT assemble. 4. Insulated versions may not be ex-stock but will generally be available within 2-3 days of ordering. 5. Should you have an ongoing requirement for an item that is not a standard stock line PLEASE discuss with us and we will review stocking the item for you.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

79

Manrose Wall/Ceiling Grilles


Fixed LOUVRE
Duct Size (mm) 100 100 100 125 125 125 150 150 150 200 230/250 300 Colour White Grey Terracotta White Grey Terracotta White Grey Terracotta White White White Order Code DCT0025 DCT0024 DCT0026 DCT0041 DCT0039 DCT0040 DCT0063 DCT0062 DCT0064 DCT0340 DCT0073 DCT1979
150mm Wall/Ceiling Grille Fixed Louvre White

Standard grille with some weather protection. Removable insert for easy cleaning.

Manrose Wall/Ceiling Grilles


EGGCRATE
Duct Size (mm) 100 125 150 Colour White White White Order Code DCT0375 DCT0472 DCT0473

150mm Wall/Ceiling Grille Eggcrate White

Improved air-flow characteristics. Removable insert for easy cleaning.

DIMENSION INFORMATION
Grille Description Fixed Louvre Grille Fixed Louvre Grille Fixed Louvre Grille Fixed Louvre Grille Fixed Louvre Grille Fixed Louvre Grille Eggcrate Grille Eggcrate Grille Eggcrate Grille Duct Size (mm) 100 125 150 200 230/250 300 100 125 150 Face Size (mm) 140 x 140 162 x 162 174 x 174 285 x 285 285 x 285 350 x 350 140 x 140 162 x 162 175 x 175 Spigot Diameter (mm) 100 122 152 199 230 285 100 122 152 Spigot Length (mm) 35 25 32 67 29 50 34 24 34 Cut-Out Size (mm) 105 127 157 240 240 295 105 127 157

80

Manrose DESIGNER Wall Grilles


STAINLESS Gravity
Duct Size (mm) 100 125 150 Colour Stainless Steel Stainless Steel Stainless Steel Order Code DCT2145 DCT2146 DCT2147

Manrose Wall Grilles


PLASTIC Gravity
Duct Size (mm) 100 100 100 125 125 125 150 150 150 230/250 300 High quality designer stainless steel finish. Stainless Steel Grade 304. Order Code DCT0029 DCT0028 DCT0027 DCT0044 DCT0042 DCT0043 DCT0066 DCT0061 DCT0065 DCT2204 DCT1981 Prevents back draughts & weather penetration. Colour White Grey Terracotta White Grey Terracotta White Grey Terracotta White White

DIMENSION INFORMATION
Spigot Diameter (mm) 97 120 145 100 122 152 230 285 Spigot Length (mm) 52 52 62 35 25 32 29 50 Cut-Out Size (mm) 115 140 160 105 127 157 240 295

Grille Description Designer Gravity Grille Designer Gravity Grille Designer Gravity Grille Standard Gravity Grille Standard Gravity Grille Standard Gravity Grille Standard Gravity Grille Standard Gravity Grille

Duct Size (mm) 100 125 150 100 125 150 230/250 300

Face Size (mm) 150 x 150 180 x 180 180 x 180 140 x 140 162 x 162 174 x 174 285 x 285 350 x 350

The Designer Gravity Grille requires a minimum pressure to open.

20Pa - 100mm (DCT2145). 30Pa - 125mm (DCT2146). 30Pa - 150mm (DCT2147).

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

81

Manrose Wall/Ceiling Grilles


Low Profile
Duct Size (mm) 100 100 125 125 150 150 Description Circular Square Circular Square Circular Square Colour White White White White White White Order Code DCT1089 DCT2223 DCT1090 DCT2224 DCT1067 DCT2225
150mm Low Profile Wall/Ceiling Grille

Low Profile eggcrate design improves airflow in extraction applications. Twist lock fascia for easy cleaning. Gib fixing clips included. Longer spigot for easy duct connection. Satin Silver & Chrome fascias available.

ACCESSORIES
Duct Size (mm) 125 125 125 125 125 125 150 150 150 150 150 150 125 150 Description Colour Order Code FAN2069 FAN2068 FAN0757 FAN0755 FAN0748 FAN0747 FAN2070 FAN2071 FAN0613 FAN0598 FAN0750 FAN0749 DCT1074 FAN0656
Accessories 150mm Low Profile Wall/Ceiling Grille - Square/Circular

Circular Fascia Satin Silver Square Fascia Satin Silver Circular Fascia Chrome Square Fascia Chrome Circular Fascia White Square Fascia White Circular Fascia Satin Silver Square Fascia Satin Silver Circular Fascia Chrome Square Fascia Chrome Circular Fascia White Square Fascia White Spigot Spigot White White

DIMENSION INFORMATION
Duct Size (mm) 100 125 150 100 125 150 Face Size (mm) 140 170 200 Spigot Diameter (mm) 98 120 150 Spigot Length (mm) 49 65 65 49 65 65 Cut-Out Size (mm) 115 135 165 115 135 165

140 x 140 98 161 x 161 120 191 x 191 150

82

Manrose DESIGNER WALL/CEILING GRILLES


SQUARE
Duct Size (mm) 150 150 Colour White Silver Order Code DCT2236 DCT2237

High quality designer finish available in either white or brushed aluminium silver. Designed for bathroom extraction that blends into any decor.
Designer Wall/Ceiling Grilles

DIMENSION INFORMATION
Duct Size Face Size Spigot Diameter (mm) (mm) (mm) 150 150 191 x 191 191 x 191 150 150 Spigot Length Cut-Out (mm) Size (mm) 65 65 157 157

Manrose WALL/CEILING GRILLES


CIRCULAR
Duct Size (mm) 100 125 150

Colour White White White

Order Code DCT2185 DCT2186 DCT2187

Concentric circular grille designed for extraction.


150mm Circular Wall/Ceiling Grille

DIMENSION INFORMATION
Duct Size (mm)
100 125 150

Face Size (mm)


140 170 200

Spigot Diameter (mm)


98 125 150

Spigot Length (mm)


49 65 65

Cut-Out Size (mm)


105 125 157

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

83

Manrose DESIGNER Ceiling Diffuser


STAINLESS STEEL
Duct Size (mm) 100 125 150 Colour Stainless Stainless Stainless Order Code DCT2139 DCT2140 DCT2141

High quality designer stainless steel finish - grade 304, Designed for internal extraction where a quality finish is required.

Designer Ceiling Diffuser

DIMENSION INFORMATION
Duct Size (mm) 100 125 150 Face Size (mm) 140 172 220 Spigot Diameter (mm) 97 120 145 Spigot Length Cut-Out Size (mm) (mm) 52 52 62 105 130 150

Manrose Flat Ceiling Diffuser


Low Profile
Duct Size (mm) 150 Colour White Order Code DCT2208

High quality designer finish. Designed to supply air into your home, by pushing the air along the ceiling and down the walls. Included in Simx Home Ventilation Systems.

Flat Ceiling Diffuser

DIMENSION INFORMATION
Duct Size (mm) 150 Face Size (mm) 220 Spigot Diameter (mm) 148 Spigot Length (mm) 80 Cut-Out Size (mm) 210

84

Ceiling DIFFUSER
CONE CENTRE
Duct Size (mm) 150 200 250 300 Colour White White White White Order Code DCT1472 DCT1473 DCT1474 DCT1475

Manufactured from ABS plastic. Designed for either supply or extract ventilation. When used to supply, the air will be pushed down into the room. These diffusers are used in heat transfer systems. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs. Adjustable screw in centre cone to ensure a balanced airflow.

200mm Ceiling Diffuser

DIMENSION INFORMATION
Duct Size (mm) 150 200 250 300 Face Size Spigot (mm) Diameter (mm) 266 317 389 400 150 200 250 300 Spigot Length (mm) 95 95 102 102 Cut-Out Size (mm) 232 282 355 405

EGGCRATE ROUND DIFFUSER


Duct Size (mm) 150 200 150 200 Colour Ice White Ice White Ice White Ice White Damper included included Order Code DCT2594 DCT2595 DCT2608 DCT2609

Manufactured from ABS plastic. Designed for either supply or extract ventilation. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs.

150mm Eggcrate Round Diffuser

DIMENSION INFORMATION
Duct Size (mm) 150 200 Face Size Spigot (mm) Diameter (mm) 240 290 150 200 Spigot Length (mm) 95 95 Cut-Out Size (mm) 215 260

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

85

CEILING DIFFUSER
ECO Diffuser
Duct Size (mm) Colour Order Code

Ceiling Diffusers
200 White

100 White DCT0020 ng system is an investment in your families personal comfort. As 125 White DCT0174 e placed on the type of ancillary products as to the type of unit 150 White DCT0058 DCT0068

s are manufactured from ABS (Acrylonitrile Butadiene Styrene) Manufactured from A.B.S plastic. type of plastic that is used products like fridge Designed for in either supply ortelephones, extract ventilation. Fixing flange included, screws required. Adjustable screw in centre cone. outside flange gives an attractive and unobtrusive finish. It is the

200mm Ceiling ECO Diffuser

s used on our other plastic diffusers. So when you purchase

products, you get a job that is aesthetically pleasing throughout

DIMENSION INFORMATION

st.

Cone Centres are designed to suit the reverse cycle systems. Cone Centres allow adjustable control of the airflow by moving the centre up or down. This is achieved by a screwing technique. Clockwise decreases and shallows Unijet Cross Section the airflow while anti-clockwise increases and deepens the airflow.

ed not to just
Duct Size Face Size (mm) 149 169 186 235 Spigot Diameter Spigot Length (mm) (mm) 99 125 148 198 47 47 50 50 Cut-Out Size (mm) 98 123 148 198

ke other

et disperses(mm) because its


100

gles.

mperature

125 150 200

Cone Centre Cross Section

Cone Centre Cross Section

d to suit the

ne Centres

f the airflow

r down. This

technique.

shallows the
Shallow Airflow Deep Airflow

se increases

poor quality remains long after the a low price has been forgotten.
ty Ltd ABN 21 005 072 873

Heidelberg West Victoria Australia 3081 86 t Heidelberg Victoria 3081 Australia 1 (0)3 9458-3120 email sales@westaflex.com.au & New Zealand

Manrose DESIGNER Weatherproof COWLS


STAINLESS COWLS
Duct Size (mm) 100 125 150 Colour Stainless Steel Stainless Steel Stainless Steel Order Code DCT2151 DCT2152 DCT2153
150mm Weatherproof Cowl

High quality designer stainless steel finish. Designed for use where adverse weather conditions are experienced. Manufactured from a Stainless Steel Grade 304.

Manrose Weatherproof COWLS


PLASTIC COWLS
Duct Size (mm) 100 100 125 150 Colour White Brown White White Order Code DCT0018 DCT0019 DCT1030 DCT1031
150mm Weatherproof Plastic Cowl

Used where adverse weather conditions are experienced. 150mm Cowl, now includes mesh as standard

DIMENSION INFORMATION
Duct Size (mm) 100 125 150 100 125 150 Spigot Diameter (mm) 97 120 145 99 124 152 Spigot Length (mm) 52 52 62 35 27 35 Cut-Out Size (mm) 115 140 160 115 140 165

Grille Description Designer Weatherproof Designer Weatherproof Designer Weatherproof Standard Weatherproof Standard Weatherproof Standard Weatherproof

Face Size (mm) 150 x 150 180 x 180 180 x 180 140 x 140 175 x 175 175 x 175

The Designer Weatherproof Cowl requires a minimum pressure to open. 10Pa - 100mm (DCT2151). 10Pa - 125mm (DCT2152). 10Pa - 150mm (DCT2153).

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

87

Manrose DESIGNER Weatherproof Dome


STAINLESS DOME Cowls
Duct Size (mm) 100 125 150 Colour Stainless Steel Stainless Steel Stainless Steel Order Code DCT2157 DCT2158 DCT2159

High quality stainless steel dome cowl for a modern stylish look. Designed for exhaust and supply ventilation. Generally mounted on an external wall, however they can be mounted internally. Manufactured from a Stainless Steel Grade 304. Insect mesh included.

150mm Weatherproof Stainless Dome Cowl

dimension information
Duct Size (mm) 100 125 150 Face Size (mm) 140 180 200 Spigot Diameter (mm) 97 120 145 Spigot Length (mm) 52 52 62 Cut-Out Size (mm) 115 140 155

Grille Description Designer Dome Cowl Designer Dome Cowl Designer Dome Cowl

88

Manrose Wall/Ceiling PLATE GRILLES


Fixed Louvre Vent
Plate Size (mm) 245 x 80 245 x 80 245 x 160 245 x 160 245 x 245 245 x 245 Colour White Chrome White Chrome White Chrome Order Code DCT2194 DCT2195 DCT2196 DCT2197 DCT2198 DCT2199
Wall/Ceiling Plate Grilles Fixed Louvre Vent

Adjustable Vent
Plate Size (mm) 245 x 80 245 x 80 245 x 160 245 x 160 245 x 245 245 x 245 Colour White Chrome White Chrome White Chrome Order Code DCT2188 DCT2189 DCT2190 DCT2191 DCT2192 DCT2193
Wall/Ceiling Plate Grilles Adjustable Vent

Manufactured from PVC in either white or chrome. Designed for use when make-up air is required. Fixed Louvre provides maximum airflow. Adjustable Vent can be fully closed off when not required.

Manrose Wall/Ceiling PLATE GRILLES


PLATE FACE
Duct Size (mm) 150 150 230 Grille Type Fixed Louvre Fixed Louvre Colour White White Order Code DCT0352 DCT0353 DCT0354

Gravity Shutter White

For situations where no spigot is required.

Manrose Door GRILLE


Model No. Door Vent Description Internal Door Ventilator Grille Order Code FAN0159

Wall/Ceiling Plate Grilles Plate Face

This door grille allows make-up air into the room. Dimensions: 455mm (h) x 90mm (w) to fit door with depth of 33mm.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

89

Roof Cowls
Duct Size (mm) 150 150 Description General Purpose Cowl Heavy Duty Cowl Order Code DCT0708 DCT0709
150mm General Purpose Cowl

General Purpose Cowl - Low profile. Low back pressure. - Added exhaust aperture area and deep vent coverage. - Recommended where high winds in exposed locations may drive rain into the vent. - Also recommended for use in high airflow air intake systems to prevent rain being sucked into the system.
150mm Heavy Duty Cowl

DIMENSION INFORMATION (mm)


Models DCT0708 DCT0709 A 275 275 B 125 140

Performance - DCT0708/DCT0709

DCT0708 and DCT0709 Pressure vs Volume


100

80

Pressure (Pa)

60

40

20

50

100

150

200

250

Volume (litre/sec)

90

Roof Cowl Kits


Duct Size (mm) 150 150 150 Description

with Flashing & HDPE Tube


Order Code DCT0172 DCT0710 DCT1095

General Purpose Kit Heavy Duty Cowl Kit General Purpose Lead Flashing Kit

General purpose cowl included. 0.5m HDPE Tube included. Flashing included (for metal based roofs). All fittings supplied. Optional lead Flashing available (extra cost).

150mm General Purpose Kit

Note: Lead Flashing (DCT0190) required for concrete tile roofs.

Plastic Reducers for HDPE Thru-Roof Tube (for thru-roof kits)


Metric Size (mm) 150:125 150:100 Description 150:125 reducer 150:100 reducer Order Code DCT2066 DCT2122

Reducers fit to the bottom of HDPE tube to adapt to smaller duct diameters where required.

Manrose Angled Roof Cowl Kit


Duct Size (mm) 125 Description Angled Roof Kit Order Code DCT2205

General purpose through roof kit for smaller applications. 110mm PVC pipe - suitable for 125mm flexible ducting. To be mounted on tile roofs. Kit includes - Cowl, 0.5m of tube & weathering slate included.
Angled Roof Kit

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

91

Manrose rangehood ducting kits


There are three ducting options available, for the kitchen rangehood. Through an adjacent wall, through the soffit (under the eave) or up through the roof. Semi-Rigid ducting is used in our top of the range systems to reduce the rangehood system noise and increase air flow performance. Fully complies to AS/NZS 60335.2.80.

Thru Wall rangehood DUCTING Kits


Duct Size (mm) 125 150 Description Rear Vent - Gravity Grille Top & Rear Vent Weatherproof Cowl Order Code DCT1162 DCT2592

For added weather protection use the weatherproof cowl as included in DCT2592.

Soffit rangehood DUCTING Kits


Duct Size (mm) 150 150 150 Description Thru Soffit Thru Soffit - Galv Tube Thru Soffit - Semi Rigid Order Code DCT1161 DCT1259 DCT2323

All systems include 3 metres of Aluminium Duct. Galv Tube system also includes 900mm of Solid Tube.

Thru ROOF rangehood DUCTING Kits


Duct Size (mm) 150 150 Description Thru Roof - Iron Thru Roof - Tiled Order Code DCT2324 DCT2325

FLASHING
Iron Roof Tiled Roof

92

Manrose Dryer Ducting Kit


Rear Vent Thru Wall
Duct Size (mm) 100 Order Code DCT1263

Kit Includes: 3m Flexible aluminium Aluduct (rated -30C to 150C). 0.75m Flat channel duct. 2 x Rectangular to Round 90 elbow bends. 100mm white eggcrate grille. All fixing and fittings.

Dryer Ducting Kit

Dryer Ducting features


This ducting kit is designed for inverted and wall mounted dryers. Free standing dryers on the floor will require extra rectangular ducting and connector (Order Code: DCT0013 & DCT0014). These ducting kits suit dryers with a 100mm outlet. The square to round elbow will fit snugly onto most 100mm dryer outlets.

Pro Series Extension Kit


Duct Size (mm) 150 150 Description Heat Trans Extension Kit SimxHome Extension Kit Order Code DCT2101 DCT2276

Kit Includes: Designed to extend your home ventilation or heat transfer systems to additional rooms. 1 x Y-Branch. 1 x 3 metres - 150mm Acoustic Insulated Ducting. 1 x Adjustable Circular Diffuser. All fixing and fittings included.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

93

Manrose Accessories
insect mesh
Duct Size (mm) 100 125 150 250 150 Description For 100mm Grilles For 125mm Grilles For 150mm Grilles For 200mm & 250mm Grilles Bird Mesh Order Code DCT0371 DCT0208 DCT0207 DCT0373 DCT2263
Insect Mesh Accessory

Duct Straps and Duct Tape


Duct Size (mm) 100mm 125mm 150mm 12mm x 3m 25mm x 50m 48mm x 5m 48mm x 30m 48mm x 60m Description Ducting Strap Ducting Strap Ducting Strap Hanging Strap Hanging Strap Duct Tape Duct Tape Duct Tape - *AS4254 Order Code FAN0274 FAN0281
Ducting Straps & Duct Tape

FAN0282 DCT2299 DCT0808 DCT0173 DCT0807 DCT1132


AS4254 Duct Tape

*AS4254 Duct tape DCT1132 - Temperature range -37C - 127C

Roof Flashings
Description Flashing Roof Flashing - fits 110-160mm Tiledek Roof Flashing - For use on concrete tile, clay tile and slate roofing 0.5m HDPE Tube 150mm Stitching Screws (for roof fastening) Order Code DCT0180 DCT0190 DCT0183 FAN0400
Roof Flashings

94

Heat Trans
Systems
HEAT TRANS uses excess heat to warm other areas of the home by transferring it from one room to multiple rooms. Heat Trans is the professional brand in heat transfer systems and is the brand of choice for electricalcontractors. Leading the market for over 15 years, Heat Trans is at the forefront of product development and innovation and the only heat transfer systems using acoustic insulated ducting and digital controllers.

How does Heat Trans work


01

MODELS

Excess heat from your heat source will rise to ceiling level where it is trapped. This excess heat can reach temperatures of 30-35C.

MODEL

Order Code

Heat Trans One Room Kit

FAN0325

Heat Trans Two Room Kit

FAN0337

Heat Trans Three Room Kit

FAN0338

02

This excess heat can be effectively transferred to other rooms using a high quality fan and acoustic insulated ducting.

Pro-Series One Outlet Extension Kit Heat Trans Summer-Vent Extension Kit

DCT2101

DCT1481

Heat Trans Thru Wall Kit

FAN0005

03

Air moves from the bedrooms back to the lounge creating a natural recirculation of warm air throughout the home. This will also make your home healthier by helping to reduce mould and mildew.

Heat Trans systems utilise excess heat throughout the home and cost as little as a light bulb to run.

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

95

Heat Trans
Systems One Room Kit
Outlet Size Description 150mm Heat Trans One Room Kit Fan Speeds 1 Order Code FAN0325

Kit includes: 1 x Ultecon Digital Thermostat Controller. 1 x 150mm High Performance Axial Flow Fan. 2 x 3 Metres - 150mm Acoustic Insulated Ducting. 1 x Circular Inlet Grille. 1 x Adjustable Circular Design Outlet Diffuser. All Fittings and Fixings Included.

Two Room Kit


Outlet Size Description 150mm Heat Trans Two Room Kit Fan Speeds Order Code 2 FAN0337

Kit includes: 1 x Ultecon Digital Thermostat/ Fan Speed Controller 1 x 150mm Multi-Speed High Performance Fan. 4 x 3 Metres - 150mm Acoustic Insulated Ducting. 1 x Branch Take-Off (Splitter). 1 x Circular Inlet Grille. 2 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included.

Three Room Kit


Outlet Size Description 150mm Heat Trans Three Room Kit Fan Speeds 3 Order Code FAN0338

Kit includes: 1 x Ultecon Digital Thermostat/ Fan Speed Controller. 1 x 200mm Multi-Speed High Performance Fan. 3 x 3 Metres - 150mm Acoustic Insulated Ducting. 2 x 3 Metres - 200mm Acoustic Insulated Ducting. 1 x Double Branch Take-Off (Three Way Splitter). 1 x Circular Inlet Grille. 3 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included.

96

Heat trans
Features
The Ultecon digital thermostat controller measures and displays the temperature of your lounge and lets you preset your preferred room temperature. When your lounge temperature exceeds your preferred room temperature the system will automatically start to transfer the excess heat to other rooms in your home. The 2 and 3 room systems also offer fan speed control, which allows you to set your preferred fan speed giving you ultimate control over the volume of heated air being transferred. Superior Fans High quality multi-speed fans for optimum airflow ventilation in the home that cost as little as a light bulb (between 70W and 120W) to run. These high quality fans have been specifically selected to ensure correct airflow and pressure levels are achieved. Whisper quiet The unique acoustic insulated ducting reduces air transfer noise to a whisper quiet level. Better temperature retention is achieved, ensuring optimal heat transfer of excess warm air. Adjustable diffusers Easily adjustable to allow balancing of the airflow into each room. Simply twist the centre section of the diffuser to allow more or less air into each room. Or simply close any diffuser when the room is not in use.
One Room Controller

Optional extras
Summer feature
Introduce fresher cooler air into your home in summer with the Summer-Vent Extension Kit, to enable year round use of your system. With the inlet grille installed under your soffit, fresher cooler air is filtered using a high efficiency F7 filter and is distributed throughout your home via your Heat Trans outlets. The system is controlled via a standard wall switch which operates the motorised damper to start drawing air from outside. Note: When the summer feature is working the lounge warmed room inlet is switched off via the damper and will not receive the cooled air directly from outside, however due to air pressure a natural re-circulation occurs throughout the home.

Two/Three Room Controller

Summer Feature Extension Kit

Extension kit
The Pro-Series One Outlet Extension Kit is designed to extend your standard three room Heat Trans system so you can distribute warm air to an extra room within your home. The extension kit gives you the flexibility to add additional outlet/s to your Heat Trans system. By adding additional outlet/s to your system you are simply dividing the available heated air amongst more rooms. Note: All Heat Trans kits can be extended. 1 Room kits can be extended to a max length of 12 metres ( 6 metres supplied in kit). 2 Room kits can be extended to a max length of 21 metres (12 metres supplied in kit). 3 Room kits can be extended to a max length of 24 metres (15 metres supplied in kit).
Pro-Series One Outlet Extension Kit

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

97

Alpha-Numeric index
Order codes
DCT0013 DCT0014 DCT0015 DCT0016 DCT0018 DCT0019 DCT0020 DCT0024 DCT0025 DCT0026 DCT0027 DCT0028 DCT0029 DCT0036 DCT0037 DCT0039 DCT0040 DCT0041 DCT0042 DCT0043 DCT0044 DCT0058 DCT0059 DCT0061 DCT0062 DCT0063 DCT0064 DCT0065 DCT0066 DCT0068 DCT0071 DCT0073 DCT0088 DCT0089 DCT0091 DCT0114 DCT0115 DCT0116 DCT0117 DCT0118 DCT0119 DCT0120 DCT0124 DCT0125 75 76 77 78 87 87 86 80 80 80 81 81 81 78 79 80 80 80 81 81 81 86 79 81 80 80 80 81 81 86 79 80 72 72 79 74 74 74 74 74 74 74 77 76 DCT0126 DCT0127 DCT0131 DCT0134 DCT0136 DCT0137 DCT0145 DCT0146 DCT0147 DCT0148 DCT0149 DCT0150 DCT0151 DCT0152 DCT0153 DCT0159 DCT0172 DCT0173 DCT0174 DCT0180 DCT0183 DCT0189 DCT0190 DCT0207 DCT0208 DCT0328 DCT0329 DCT0330 DCT0331 DCT0332 DCT0333 DCT0334 DCT0335 DCT0336 DCT0337 DCT0338 DCT0339 DCT0340 DCT0343 DCT0344 DCT0352 DCT0353 DCT0354 DCT0357 76 76 76 78 76 77 75 75 75 78 78 78 75 75 75 79 91 94 86 94 94 56 94 94 94 72 72 72 72 72 74 74 74 74 74 74 79 80 72 72 89 89 89 72 DCT0358 DCT0359 DCT0360 DCT0362 DCT0366 DCT0367 DCT0368 DCT0369 DCT0370 DCT0371 DCT0373 DCT0375 DCT0377 DCT0380 DCT0399 DCT0400 DCT0401 DCT0402 DCT0403 DCT0404 DCT0405 DCT0406 DCT0409 DCT0410 DCT0411 DCT0412 DCT0413 DCT0414 DCT0415 DCT0416 DCT0417 DCT0418 DCT0460 DCT0461 DCT0472 DCT0473 DCT0477 DCT0511 DCT0519 DCT0520 DCT0521 DCT0522 DCT0523 DCT0524 72 72 40 40 40 72 72 72 72 94 94 80 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 79 79 80 80 74 78 75 76 77 77 77 76 DCT0525 DCT0526 DCT0527 DCT0528 DCT0633 DCT0634 DCT0635 DCT0636 DCT0708 DCT0709 DCT0710 DCT0719 DCT0723 DCT0724 DCT0725 DCT0807 DCT0808 DCT0833 DCT0834 DCT0835 DCT0836 DCT0875 DCT0876 DCT0877 DCT0878 DCT0935 DCT0936 DCT0937 DCT0938 DCT0939 DCT0940 DCT0953 DCT0954 DCT1030 DCT1031 DCT1067 DCT1074 DCT1076 DCT1089 DCT1090 DCT1095 DCT1097 DCT1114 DCT1132 76 76 78 78 73 73 73 73 90 90 91 79 79 79 79 94 94 73 73 73 73 79 79 79 79 79 74 74 74 79 79 75 75 87 87 82 82 82 82 82 91 61 76 94 DCT1161 DCT1162 DCT1164 DCT1169 DCT1171 DCT1176 DCT1216 DCT1224 DCT1259 DCT1263 DCT1268 DCT1414 DCT1424 DCT1425 DCT1426 DCT1439 DCT1440 DCT1441 DCT1442 DCT1443 DCT1444 DCT1445 DCT1446 DCT1447 DCT1448 DCT1450 DCT1451 DCT1452 DCT1453 DCT1455 DCT1456 DCT1458 DCT1459 DCT1460 DCT1461 DCT1472 DCT1473 DCT1474 DCT1475 DCT1479 DCT1480 DCT1481 DCT1482 DCT1501 92 92 73 40 40 73 73 73 92 93 73 77 75 75 75 79 77 77 76 75 77 78 76 76 76 77 77 76 77 76 76 78 76 75 76 85 85 85 85 76 77 95 76 79

98

Alpha-Numeric index
Order codes
DCT1519 DCT1520 DCT1521 DCT1522 DCT1979 DCT1981 DCT2066 DCT2066 DCT2067 DCT2092 DCT2095 DCT2096 DCT2097 DCT2098 DCT2099 DCT2101 DCT2101 DCT2120 DCT2121 DCT2122 DCT2122 DCT2139 DCT2140 DCT2141 DCT2145 DCT2146 DCT2147 DCT2151 DCT2152 DCT2153 DCT2157 DCT2158 DCT2159 DCT2185 DCT2186 DCT2187 DCT2188 DCT2189 DCT2190 DCT2191 DCT2192 DCT2193 DCT2194 DCT2195 38 38 38 38 80 81 79 91 79 78 77 77 76 76 76 93 95 40 40 79 91 84 84 84 81 81 81 87 87 87 88 88 88 83 83 83 89 89 89 89 89 89 89 89 DCT2196 DCT2197 DCT2198 DCT2199 DCT2200 DCT2201 DCT2202 DCT2204 DCT2205 DCT2206 DCT2208 DCT2223 DCT2224 DCT2225 DCT2236 DCT2237 DCT2263 DCT2276 DCT2299 DCT2323 DCT2324 DCT2325 DCT2592 DCT2594 DCT2595 DCT2608 DCT2609 FAN0005 FAN0012 FAN0013 FAN0015 FAN0016 FAN0017 FAN0018 FAN0021 FAN0038 FAN0041 FAN0042 FAN0044 FAN0046 FAN0047 FAN0048 FAN0053 FAN0054 89 89 89 89 78 78 78 81 91 78 84 82 82 82 83 83 94 93 94 92 92 92 92 85 85 85 85 95 46 46 63 63 36 36 26 20 20 20 14 14 14 14 24 24 FAN0055 FAN0060 FAN0061 FAN0064 FAN0065 FAN0071 FAN0072 FAN0074 FAN0075 FAN0080 FAN0082 FAN0083 FAN0085 FAN0090 FAN0091 FAN0101 FAN0102 FAN0107 FAN0109 FAN0110 FAN0119 FAN0120 FAN0121 FAN0122 FAN0123 FAN0124 FAN0126 FAN0127 FAN0135 FAN0136 FAN0137 FAN0138 FAN0140 FAN0141 FAN0146 FAN0148 FAN0153 FAN0155 FAN0156 FAN0157 FAN0159 FAN0213 FAN0274 FAN0281 24 46 46 36 36 14 14 14 14 24 24 24 44 46 46 36 36 26 26 26 14 14 14 14 14 14 14 14 24 24 24 24 24 24 28 28 63 63 63 63 89 78 94 94 FAN0282 FAN0325 FAN0325 FAN0326 FAN0327 FAN0328 FAN0329 FAN0330 FAN0337 FAN0337 FAN0338 FAN0338 FAN0346 FAN0348 FAN0355 FAN0357 FAN0358 FAN0360 FAN0361 FAN0372 FAN0374 FAN0397 FAN0400 FAN0405 FAN0406 FAN0409 FAN0410 FAN0411 FAN0412 FAN0413 FAN0420 FAN0431 FAN0431 FAN0438 FAN0452 FAN0455 FAN0467 FAN0481 FAN0482 FAN0499 FAN0501 FAN0504 FAN0505 FAN0518 94 95 96 48 48 36 36 50 95 96 95 96 16 16 26 50 50 50 50 62 16 60 94 46 46 24 24 24 60 60 40 38 40 40 26 16 50 28 28 20 20 20 20 28 FAN0519 FAN0520 FAN0521 FAN0529 FAN0530 FAN0531 FAN0532 FAN0533 FAN0534 FAN0535 FAN0589 FAN0590 FAN0591 FAN0594 FAN0595 FAN0596 FAN0598 FAN0598 FAN0598 FAN0604 FAN0605 FAN0606 FAN0609 FAN0610 FAN0611 FAN0613 FAN0613 FAN0613 FAN0614 FAN0615 FAN0616 FAN0617 FAN0618 FAN0619 FAN0620 FAN0621 FAN0623 FAN0625 FAN0626 FAN0644 FAN0656 FAN0685 FAN0686 FAN0690 28 28 28 56 56 56 56 56 56 56 12 12 12 12 12 12 12 22 82 12 12 12 12 12 12 12 22 82 22 22 34 34 34 34 22 22 22 61 61 82 82 61 61 61

Thomas and Betts | www.manrose.com.au | austsales@tnb.com.au

99

Alpha-Numeric index
Order codes
FAN0691 FAN0732 FAN0735 FAN0738 FAN0739 FAN0740 FAN0748 FAN0750 FAN0755 FAN0755 FAN0755 FAN0757 FAN0757 FAN0757 FAN0803 FAN0804 FAN0827 FAN0829 FAN0830 FAN0841 FAN0884 FAN0885 FAN0916 FAN0921 FAN0940 FAN0963 FAN0967 FAN0981 FAN0982 FAN0983 FAN0995 FAN0997 FAN1002 FAN1004 FAN1005 FAN1006 FAN1007 FAN1009 FAN1014 FAN1015 FAN1043 FAN1048 FAN1050 FAN1051 61 22 22 22 56 56 82 82 12 22 82 12 22 82 40 40 40 52 52 60 18 18 44 49 30 62 56 63 63 63 30 49 56 42 42 42 42 56 30 30 60 42 42 42 FAN1053 FAN1060 FAN1096 FAN2029 FAN2030 FAN2031 FAN2032 FAN2033 FAN2034 FAN2035 FAN2036 FAN2037 FAN2038 FAN2040 FAN2040 FAN2041 FAN2042 FAN2043 FAN2049 FAN2050 FAN2051 FAN2066 FAN2067 FAN2068 FAN2068 FAN2068 FAN2069 FAN2069 FAN2069 FAN2070 FAN2070 FAN2070 FAN2071 FAN2071 FAN2071 FAN2076 FAN2078 FAN2101 FAN2101 FAN2101 FAN2104 FAN2124 FAN2125 FAN2126 42 56 63 38 38 38 38 38 38 38 38 40 40 16 16 16 16 16 32 32 32 48 48 12 22 82 12 22 82 12 22 82 12 22 82 40 46 38 40 62 63 42 42 42 FAN2127 FAN2162 FAN2200 FAN2205 FAN2206 FAN2213 FAN2214 FAN2229 FAN2230 FAN2286 FAN2287 FAN2303 FAN2402 FAN2423 FAN2424 FAN2425 FAN2426 FAN2444 FAN2465 FAN2902 FAN2903 FAN4395 FAN4396 FAN4397 LHT0081 LHT0140 42 30 30 103 103 102 102 104 104 58 58 54 62 54 54 54 54 62 18 58 58 58 58 58 30 30

100

Energy Efficient Ventilation Solutions

Lo-Carbon

Lo-Carbon fans from Vent-Axia offer up to 70% energy savings by utilising market leading motor technology, to help reduce your carbon footprint.

Lo-Carbon
Thomas & Betts are proud to be the distributor of the Vent-Axia Lo-Carbon range of ventilation fans.
MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens.

Vent-Axia Lo-Carbon long life motors last 5 times longer than conventional AC motors. The extended life of the Lo-Carbon fans is due to the use of a new generation of high quality ball bearingmotor. These high quality ventilation fans are specifically designed for bathrooms, extracting moisture laden air quietly & effectively.

Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia
Unit 2, 22 Hammond Rd Cockburn Central WA 6164

South Australia
86A Richmond Rd Keswick SA 5035

Victoria
2/13-15 Brough St Springvale VIC 3171

Queensland
26 Turbo Drive Cooparoo QLD 4151

Tasmania
Electrical Agencies 4 Linear Court Moonah TAS 7009

Newcastle
Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322

National Support Centre


Phone: 1300 666 595 Fax: 1300 666 594 Email: austsales@tnb.com Web: www.manrose.com.au

Energy Efficient Ventilation Solutions

67% en savin ergy g

The distributors of Manrose Ventilation fans are proud to distribute the Vent-Axia Lo-Carbonrange.
These fans offer up to 70% energy savings, utilising market leading motor technology, which lasts considerably longer than conventional AC motors. These high quality ventilation fans are specifically designed to extract moisture-laden air quietly andefficiently. The Vent-Axia Lo-Carbon range includes solutions for wall, ceiling, window and roof mounted applications. With energy savings in mind these models operate efficiently at lower wattage levels, the Silhouette LCS150 for example operates at 8.2W as opposed to a standard ceiling fan which operates at 25W, a saving of 67%.

Lo-Carbon

VENT-AXIA LO CARBON vent-a-light fan


100 VENT-A-Light
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 70% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearingmotors. 100mm Lo Carbon axial in-line shower fan and light kit. Suitable for shower enclosures and wet areas. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation.

Low Power consumption - 70% energy savings. Complete with 3m flexible ducting, white grille and light transformer. 1 of 2 speeds selectable at installation. High quality ball bearing motors. Modern aesthetics, includes blue neon on light. Fan IPX4 rated. 5 Year Warranty.
70% sav energy ing s

Performance
Size (mm) Extract Performance* Watts Model No. Description (m3/hr) Vent-a-light B Vent-a-light T Lo-Carbon Vent-a-Light Standard Lo-Carbon Vent-a-Light Timer 110 110 (l/s) 31 31 (W) 6.5 +35 6.5 +35 Sound dB(A) @3m 23 23 FAN2229 FAN2230 Order Code

100 100

* 1 of 2 speeds selectable at installation * Please note the energy savings only apply to the fan motor, there is still a 35W centre lamp.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery.

VENT-AXIA LO CARBON wall/ceiling mounted fans


Silhouette 150
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 67% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearingmotors. With a slim profile of only 19mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaustoutside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. 19mm stylish low profile grille. Low Power consumption - 67% energy savings. Downstream airflow guide vanes for improved pressure development. 1 of 2 speeds selectable at installation. High quality ball bearing motors. Modern aesthetics, includes blue neon on light. Fan IPX4 rated. 5 Year Warranty.
67% sav energy ing s

Performance
Size (mm) Model No. Extract Performance* Watts Sound Description (m3/hr) Lo-Carbon Wall/Ceiling Silhouette Standard Lo-Carbon Wall/Ceiling Silhouette Timer 165 241 165 241 (l/s) 46 67 46 67 (W) 5 8.2 5 8.2 dB(A) @3m 35 43 35 43 FAN2213 Order Code

150

LCS150B

150

LCS150T

FAN2214

* 1 of 2 speeds selectable at installation

Wattage Comparison
Size (mm) 150 150 Model No. XFLP150 LCS150 Description Manrose Pro-Series Wall/Ceiling Fan Vent-Axia Lo-Carbon Wall/Ceiling Fan Energy Savings Wattage 25W 8.2W 16.8W

67%
ENERGY SAVINGS

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery.

Thomas & Betts | www.manrose.com.au | austsales@tnb.com.au

VENT-AXIA LO CARBON wall/ceiling mounted fans


Silhouette 100
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 63% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearingmotors. With a slim profile of only 17mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaustoutside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. 17mm stylish low profile grille. Low Power consumption - 63% energy savings. Downstream airflow guide vanes for improved pressure development. 1 of 2 speeds selectable at installation. High quality ball bearing motors. Modern aesthetics, includes blue neon on light. Fan IPX4 rated. 5 Year Warranty.
63% sav energy ing s

Performance
Size (mm) Model No. Extract Performance* Watts Sound Description (m3/hr) Lo-Carbon Wall/Ceiling Silhouette Standard Lo-Carbon Wall/Ceiling Silhouette Timer 95 60 95 60 (l/s) 26 16 26 16 (W) 7.5 3.4 7.5 3.4 dB(A) @3m 34 38 34 38 FAN2205 Order Code

100

LCS100B

100

LCS100T

FAN2206

* 1 of 2 speeds selectable at installation

Wattage Comparison
Size (mm) 100 100 Model No. XF100 LCS100 Description Manrose Wall/Ceiling Fan Vent-Axia Lo-Carbon Wall/Ceiling Fan Energy Savings Wattage 20W 7.5W 12.5W

63%
ENERGY SAVINGS

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral. NOTE: All fan flow rates quoted are free air delivery.

You might also like