You are on page 1of 2

Sarasota Fiscal Density Meter FD960

The Sarasota FD960 density meter is designed for high accuracy measurement of high value process liquids and slurries.

Features
continuous on-line density measurement accuracy to 0.0001g/cm3 reading straight through flow hazardous area applications insensitive to plant / pipeline vibration wide operating temperature span low pressure drop intrinsically safe and compact design

Applications
batch control multi-product pipeline metering product interface detection custody transfer

high flow rate capability no on-site calibration required secondary containment

Dimensional drawing
198mm 128mm

89mm

206.5mm 530mm

Detailed specification and ordering information: see overleaf


Thermo Measurement reserves the right to alter specifications without notice.

ISSUE: FD960/MAY2001/UK

271mm

Specification
Transducer:
Operating range: Factory calibration range: Accuracy: Repeatability: Temperature effect: (corrected) see Note 1 Process temperature: Pressure effect: (corrected) see Note 1 Operating pressure: Materials of construction: 0 to 2.1g/cm3 0.65 to 1.6g/cm3 0.0001g/cm3 0.00002g/cm3 0.000005g/cm3 /C -50 to +110C 0.000003g/cm3 /bar As flange rating Sensor Ni-Span-C Other wetted materials 316L stainless steel Case 316L stainless steel Electronics housing copper free aluminium grey epoxy finish High accuracy 13 DIN Integral 4 wire PT100 IP65 FD960F EEx ia IIC T6 EEx d IIC T4/T3 Weight: Installation: Flow range: Nett 11kg max Shipping 20kg max Vertical as standard Optionally horizontal 0-300 l/min 5-300 l/min when installed horizontally

Electrical: Output:

Power supply: Connections: Cable entry: Operating temperature (ambient):

Frequency related to density on 2 wire current modulated loop 6mA to 18mA 4 wire PT100 16-28 VDC 10mA average (peak 18mA) Screw terminals 2 x 34 NPT -20 to +70C

Temperature measurement:

General:
Environmental protection: Hazardous area certification:

Note 1 - Corrected temperature and pressure effects after applying correction coefficients

Ordering Information
Density meter model code format FD960 Sarasota Fiscal Density Meter Signal output F Frequency output Transducer accuracy 1 0.0001g/cm3 Temperature range F -50 to +110C Process connections B0 1 ANSI B16.5 Class 150 RF flanges B1 1 ANSI B16.5 Class 150 DUPLEX flanges F0 1 ANSI B16.5 Class 300 RF flanges F1 A0 A1 D X Note: Where an X option is chosen the option must be described fully, in writing. Please contact sales office for pricing. 1 ANSI B16.5 Class 300 DUPLEX flanges 1 ANSI B16.5 Class 600 RF flanges 1 ANSI B16.5 Class 600 DUPLEX flanges BS4504 PN40 DN25 RF flanges (form D) Other flange type (see note) Certification S Non-hazardous / safe area application I D Intrinsically safe EEx ia IIC T6 Flameproof EEx d IIC T4/T3 Options M Wetted parts material certificates (DIN 50049 BS EN 10204 3.1b) T Traceable calibration certificate

Example:

FD960-F-1-F-A0-S

FD960 fiscal density meter with frequency output, 0.0001g/cm3, standard temperature range, 1 ANSI Class 600 RF flanges for use in non-hazardous areas.

Thermo Electron Corporation Kings Worthy Winchester, Hampshire SO23 7QA, United Kingdom Tel: +44 (0) 1962 625000 Fax: +44 (0) 1962 885530 email: sales@thermomeasurement.com www.thermo.com

Thermo Electron Corporation 9303 W. Sam Houston Parkway South Houston Texas 77099 5298 USA Tel: +1 (713) 272 0404 Fax: +1 (713) 272 2273

HART is a registered trademark of the Hart Foundation