Professional Documents
Culture Documents
INTRODUCTION TO KRUEGER
Grilles, Registers, Diffusers Air Distribution Engineering Plaque & Architectural Diffusers Louvered Face Diffusers Perforated Face Diffusers Modular Core Diffusers Linear Slot Diffusers Plenum Slot Diffusers Round Diffusers Air Nozzles & Round Grilles Supply Grilles Return Grilles Linear Bar Grilles Security Grilles & Diffusers Industrial Grilles Duct Mounted Grilles Transfer Grilles Stainless Steel Grilles Accessories a1 - 01 A1 - 01 B1 - 01 C1 - 01 D1 - 01 E1 - 01 F1 - 01 G1 - 01 H1 - 01 I1 - 01 J1 - 01 K1 - 01 L1 - 01 M1 - 01 N1 - 01 O1 - 01 P1 - 01 Q1 - 01
VOLUME 1
Terminal Units & Fan Coils Terminal Unit Engineering Single Duct Terminal Units Fan Powered Terminal Units Dual Duct Terminal Units Retrofit / Bypass Terminal Units Fan Coil Engineering Fan Coils a2 - 01 A2 - 01 B2 - 01 C2 - 01 D2 - 01 e2 - 01 E2 - 01
VOLUME 2
VOLUME 3
VAV Diffusers Critical Room Solutions Chilled Beams Displacement Ventilation Underfloor Products A3 - 01 B3 - 01 C3 - 01 D3 - 01 E3 - 01
Specialty Products
Krueger Edition 8 Product Catalog. Printed in the USA. 2012 Krueger, Division of Air System Components, Inc. All Rights Reserved. Please note that drawings, specifications, and other information contained within this Product Catalog is subject to change at any time, without notice. To access the latest information, visit us on the web at www.krueger-hvac.com.
Our People
Krueger takes pride in developing and maintaining a strong, unified team, both within the organization and through the relationships we build with owners, engineers, contractors, and sales representatives throughout the industry. With hundreds of years of combined experience in the HVAC business, our staff is eager to share a wealth of experience and knowledge.
Our Products
Krueger strives to offer a diverse product line, from addressing commodity products to highly customized solutions. A far contrast from when the company was founded, today we offer products for a variety of applications, including grilles, registers, diffusers, terminal units, fan coils, chilled beams, displacement ventilation, critical room and fan filter units, as well as underfloor products.
With facilities located across the United States, Krueger has the manufacturing capacity to meet the demand for even the largest jobs. Reduced distances between plants and job sites allows us to make timely deliveries that you can count on time after time. Through investments in new equipment and processes, we are able to offer higher quality product with shorter manufacturing times, which is a requirement in todays fastpaced construction market.
www.krueger-hvac.com
Education
The Krueger Institute of Technology (KIT) has, for years, been a resource for architects, contractors, and engineers to gain understanding of air distribution principles, products, and system design. With the relocation of our Research, Development, and Demonstration Center to Richardson, TX in 2011, we have made our training classes more flexible and interactive, without losing sight of core product, design, and application information.
Our team approach to business gives our customers a variety of reliable contacts to satisfy their needs. Whether it is through the product management and applications group to answer technical questions or through the depth and knowledge of our experienced customer support team, Krueger strives to provide world-class customer service every day.
Representative Channel
Krueger Representatives, located throughout North America and internationally, are a valuable resource available to assist you with application questions, pricing, and availability. Their partnership with Krueger offers an intimate understanding of air distribution needs in individual markets and the various solutions available. Many of our Representatives stock our products to ensure that the products you specify are available for your project, even when the construction schedule is compressed. Experience excellence in product representation. Call your local Krueger Representative today!
Krueger pioneered the use of Air Diffusion Performance Index (ADPI) for the selection of diffusers by placing ADPI selection charts in our catalog for every diffuser. These charts, as the example shows below, will assist you in achieving a design which will meet the ASHRAE 55* vertical stratification requirement. Our selection software has been updated to include additional ADPI calculation graphs to provide documentation to aid in achieving the LEED Comfort point.
*V3-2009 LEED-NC Credit 7.1 may be awarded for complying with ASHRAE Standard 55-2004. This standard limits vertical temperature stratification, within the occupied zone to no greater than 5F. Assuring an ADPI of no less than 80% will comply with a critical part of this requirement.
90
GreenTouch
Initiative
Proud Member Since 2008 Supporting Sustainable Green Building Design
ADPI
80 70 0.0
0.2
0.4
0.6
0.8
1.0
CFM/Sq.Ft.
www.krueger-hvac.com
Conserving Energy
Saving energy is a key goal in the design of new buildings. Krueger offers a full range of products and technologies that offer energy savings over traditional HVAC solutions, such as ECM motors in our fan powered terminal units and fan filter products, the revolutionary LineaHeat timeproportional electric heat option, VAV diffusers, chilled beams, displacement ventilation, and underfloor products. Supported by Kruegers selection software and other electronic tools, engineers have a wide variety of products and designs to choose from that will result in reduced energy consumption, regardless of the application.
www.krueger-hvac.com
Reverb Room
The Reverb Room is key for the acoustical testing of air distribution products. Its construction, like our previous Reverb Room in Tucson, AZ, began by physically isolating the floor and ceiling from the rest of the buildings structure to eliminate any structure induced sound intrusions. The new room is larger, which allows us to test larger pieces of equipment, provides more accurate low frequency sound data acquisition, and gives us the ability to test at higher airflows. We also enhanced the silencing to reduce the possibility of supply-fan generated sound reaching the test chamber. Before the room could be used to test products, it was independently tested for compliance to the Engineering Accuracy of the ANSI Specifications for reverb rooms.
Hospital OR Environment
The Krueger Operating Room (OR) Demonstration Cell contains a full scale Sterilflo OR Air Distribution System. (This consists of both the center laminar flow panels over the operating table, the proprietary air curtain around the operating theater, and low sidewall room exhausts.) The room has typical airflow obstructions often found in operating rooms, including special surgical lights that are mounted on movable booms. The demonstration area has a separate space for showcasing the performance of a 4 x 8 array of laminar flow diffusers or fan filter units. This array is located within the same space for direct comparison with the Sterilflo System, as the use of laminar arrays is typical in some OR air distribution layouts. Additionally, Krueger is able to mock-up a work bench under the array to further demonstrate clean room products in more realistic environments.
Reverb Room
www.krueger-hvac.com
Specialty Products
The Krueger Specialty Products Demonstration area is a showcase for special and innovative air distribution concepts. Separated from the main Throw Bay by a Cold Wall, the room is configured with fully operational ceiling mounted Chilled Beams, both active and passive. The room has the capability to adjust humidity levels in the space to demonstrate the performance of the Chilled Beams at different design conditions. Feeding the DesignFlo along the Cold Wall is the KLPS-D Chilled Series Fan Powered Terminal Unit designed for DOAS applications. This unit features a cooling coil that, much like a Chilled Beam, provides sensible cooling to the space, making it a natural partner to use with Chilled Beams on a project. The room also features a raised floor that is configured to demonstrate different design solutions for raised floor applications. There is a pressurized plenum that supplies FPD-R swirl outlets. There are several types of VAV terminal units located beneath the floor that supply different layouts of FPD-D/FPD-HC plenums for 1850 linear bar grille diffusers. The final product that is featured in this room is Displacement Ventilation. The room can be configured to demonstrate different models and layouts of Displacement Ventilation units to show the performance.
Critical Room Lab Mock-up Krueger | Providing You With Air Distribution Solutions
Krueger understands that there are unique buildings and different situations that require special attention, which often are only resolved through the development of new or niche products. By understanding the requirements of the product, the limitations of the situation, and how it will integrate with the overall air distribution system, Krueger Engineering is able to put forth their expertise to thoroughly research and develop a product that can meet those needs. One such example is Kruegers KLPS Size 1 ultra low profile series fan powered terminal unit. This product was developed in coordination with the local Krueger Representative and their customer to solve the issue of retrofitting older buildings in Washington D.C., where the shallow ceiling plenum between floors limited the use of other products. After research, prototypes, and testing, Kruegers Engineering team successfully developed a product that met the customers needs, which resulted in several successful installations. The KLPS size 1 is now a standard product offering available to everyone.
Generate Drawings
We are constantly involved in projects that require customized drawings, such as Kruegers Sterilflo operating room particulate control system. Our Engineering team is able to provide a clear, complete drawing package for each system that includes a reflected ceiling view, plan view, and cross section view along with installation details. The drawing packages ensure the customer has all the necessary information to achieve a successful project. For curved products, such as DesignFlo, 1900, or linear bar grilles, Krueger is able to quickly turn around approval drawing packages, complete with the radius and arc length dimensions to verify that the custom linear product will be built to the exact project specifications.
10
www.krueger-hvac.com
Revit Blocks
To achieve greater control and detail of your air distribution designs, use Kruegers Revit Building Information Modeling (BIM) blocks. While we offer blocks for a variety of our products, for the terminal units specifically, our blocks are configured with unit specific information to help ensure that the product selection corresponds to the drawing information. To learn more about the blocks available, visit the Krueger website at www.krueger-hvac.com/revit.
Application Engineering
The primary responsibility of our Application Engineering team is to provide technical product support and assist in the proper selection and specification of Krueger air distribution products. Working closely with Product Managers and Design Engineers, they aid in product development as well as the execution of special or custom orders. They also help to resolve challenging application opportunities, provide guidance, and are able to discuss solutions that may deliver more optimal results.
11
OUR TRAINING
Krueger Institute of Technology
Kruegers commitment to education is second to none. It is what allows us to grow stronger as individuals, perform better as a team, and be your strategic partner in the design of better air distribution systems.
The goal of Kruegers Institute of Technology (KIT) is to educate engineers, architects, contractors, and building owners on the proper design and specification of air distribution products in commercial and industrial applications. It is our firm belief that by cultivating individuals and empowering them with the knowledge of proper air distribution design practices, we not only improve our ability to support our customers, but as a result, help the industry design and specify more effective and efficient HVAC systems. Whether a seasoned veteran with years of knowledge or someone just entering the industry, our wide array of demonstrations, activities, and exercises facilitate open discussions, allowing every person to take away something new. Our focused approach, targeting specific product groups during each program, allows us to provide a more comprehensive curriculum that integrates a greater amount of design and application knowledge than ever before. For more information on our training programs, visit us on the web at www.krueger-hvac.com/kit or simply contact your local Krueger Representative.
Shown right, product displays throughout Kruegers Technology Center.
12
www.krueger-hvac.com
A Hands-on Experience
Kruegers Institute of Technology delivers a truly different type of training, one that focuses on discussions and hands-on experiences to help illustrate key concepts. Whether working on group exercises or viewing a product smoke demonstration, we aim to provide a solid foundation of product knowledge and proper application so that a customers selection works well in their system design.
Experienced Staff
Throughout all of our training classes, we employ a variety of staff, from Product Managers and Application Engineers to Sales and Marketing. With hundreds of years of industry experience combined, you can rest assured that there will always be a specialist available to answer even the most complex question.
KR UE
NSTITUTE I OF ER G
Critical Room Product Training This class discusses how and when to utilize specialized products, such as Kruegers Sterilflo and Sterilflex operating room systems, laminar flow panels, radial flow diffusers, and fan filter units. Representative Training For Krueger Representatives, this course centers on providing the tools and knowledge to more effectively assist customers in the marketplace, such as owners, engineers, architects, and contractors.
TE
Private Programs
In addition to formal KIT classes, we encourage our Representatives to bring their contractors, engineers, architects, and building owners to visit our facility for a more customized training experience to fulfill the immediate needs of their business. Visits can range from a one hour tour and overview of our product offering to multiple day sessions with in-depth discussions and training on product, applications, and design.
ENG
13
IN
OUR E-TOOLS
Simple Design with Comprehensive Information
A tool by definition is an instrument that can increase the speed and/or accuracy of accomplishing a task. The goal of our suite of electronic tools is to provide the information you need to quickly, as well as properly design and specify air distribution products from within easy-to-use interfaces.
Even for the most skilled engineers, designing and specifying air distribution products is never an easy task. Using Krueger Electronic Tools (e-Tools), engineers and architects are able to capture useful design information and make informed product selections that result in optimal air distribution. In addition to product information, we include helpful design features in our programs, such as the Chilled Beam and Displacement Ventilation selection software, which displays airflow illustrations to better help one understand the room air motion of given selections. For grilles and registers, we offer custom performance data spreadsheets for nearly every model, which allows one to obtain precise information on any specific size of product. We also make available a program to determine acceptable limits of temperature, airspeed, and humidity for building occupants, and another that aids in generating text specifications. For Krueger Representatives, we provide access to an allencompassing selection and pricing program. Not only are we able to streamline the order process through importing engineer selections, but we are able to release new products to market faster than ever before. From selection to performance, from comfort to sound, Krueger offers a wide selection of electronic tools to aid in the design and specification of air distribution products.
14
www.krueger-hvac.com
Spreadsheets
Available on the website within our on-line Product Catalog for grilles, register, and diffuser products are spreadsheets that detail custom performance data based on your inputs. These can be accessed within each product model page, easily edited, and saved on your local computer.
Calculators
Comfort, sound, and product calculators are designed to assist in the specification process by providing necessary information to properly select air distribution products while maintaining occupant comfort and meeting building requirements. They will help determine the acceptable limits of temperature, air speed, and humidity for building occupants in both mechanically and naturally conditioned spaces, as well as assist by providing text specifications. These tools can be downloaded from the Krueger website or found within our selection software programs. Other helpful information-rich areas under our Resources menu on the Krueger website.
15
OUR COMMUNICATIONS
Accessibility to Information
We understand the value of finding information quickly and in the format that you most prefer, which is why Krueger offers such a broad selection of communication formats.
Krueger is committed to offering you all the information and tools you need to select and specify air distribution solutions with confidence. From technical product information, such as our performance data, dimensional drawings, specifications, and calculators to educational-based items like case studies, FAQs, white papers, and application models, we strive to deliver helpful information in a clear and concise manner. Across the different types of media we use, you will find it easier than ever to access new product information and stay up-todate with what is happening within Krueger. Simply contact your local Krueger Representative to obtain new product brochures, visit us on the web at www.krueger-hvac.com, or follow us on our social media sites for news and announcements. Just as much as we acknowledge the value of accessing information quickly, we also understand the importance of talking to someone directly, which is why our Regional Sales Managers, Product Managers, Chief Engineer, and Application Engineers regularly visit with Krueger Representatives and their customers to answer questions and discuss projects. It is just one of the many ways we work to ensure that your air distribution solution is one that provides the performance you need, the aesthetics you desire, and is delivered on time, with confidence.
www.krueger-hvac.com
Website & Selection Software
Kruegers website is continually updated with information, including electronic versions of our printed brochures and Product Catalog, REVIT file downloads, calculators, selection software, FAQs, videos, webinars, training, a local Krueger Representative index and more!
16
www.krueger-hvac.com
Literature
In addition to Kruegers Product Catalog, we also make available brochures and flyers, case studies, color charts and more. Simply contact your local Krueger Representative to obtain your copy, or find electronic versions on the website at www.krueger-hvac.com.
Social Media
Stay up-to-date with all the latest product developments, training reminders, videos and more through these social media outlets.
www.twitter.com/KruegerHVAC
www.facebook.com/KruegerHVAC
www.youtube.com/KruegerHVAC
17
OUR PRODUCTS
Delivering Occupant Comfort Every Day
Krueger continues to expand their product offering to satisfy building occupants while meeting the ever-changing needs of building owners, contractors, architects, and engineers.
Krueger provides a wide selection of air distribution solutions for numerous applications. Our air distribution product offering now includes a greater selection of plaque face diffusers, air nozzles and round grilles, as well as new TechZone friendly linear slot diffusers. Leading the development of products for emerging trends, our terminal unit products offer solutions for fresh air applications and compatibility with Direct Outdoor Air Systems (DOAS). For low velocity supply air applications, learn more about our selection of displacement ventilation products. These diffusers utilize natural buoyancy forces created by the convective flows from heat sources in the space to comfortably and quietly supply air to occupants. Find green product solutions in Kruegers chilled beams, which use the inherently energy-efficient method of transferring energy through water. For sensitive applications, such as hospitals, cleanrooms, or laboratories, Krueger delivers a selection of proven, world-class solutions that will protect those that are in the critical spaces without disturbing surrounding processes. A wide range of underfloor products, including floor diffusers and grilles as well as mixing units, will allow you to build an air distribution system that meets the needs of high churn applications. Popular in high-rise and hotel applications, our fan coils allow for complete customization, making them a great solution for retrofit or architecturally complex building designs.
Terminal Units
Displacement Ventilation
Chilled Beams
Underfloor Products
Fan Coils
18
www.krueger-hvac.com
Product Gallery
In addition to our Product Index in the back of each volume, you will find a Product Gallery on the following pages to help you both locate products within the Product Catalog as well as assist you in the process of learning about Kruegers many air distribution product solutions.
19
OUR PRODUCTS
Terminal Units and Underfloor Products
LMHS
Single Duct Terminal Unit A2-3
LMHD
LMHDT
KQFS / KQFP
KQFS-FA
Ultra Quiet, Series Fresh Air Fan Powered Terminal Unit B2-19
QFC/QFV
KLPS / KLPP
KLPS-D
RVE
SVE
KLB
KMS
KUFS
KBF
KUFM
FPD-R, FPD-D / V / HC
Helical Slot Diffuser & Grille Duct Connection E3-15 / E3-18
20
www.krueger-hvac.com
Fan Coils
HFH
Horizontal Standard, Concealed Ceiling Fan Coil E2-4
HFHP
HFEC
HFI
HGH
HGHP
HGEC
VFH
VFFC
VFSC
VFLC
VFLH
VGH
VPH
VPHP / VPHS
VPIP / VPIS
Vertical Stack, Recessed Primary & Secondary Twin Pack Fan Coil E2-68
21
OUR PRODUCTS
Square/Rectangular Ceiling Diffusers
PRISM
Arcuate Face with Appliqu, Architectural Ceiling Diffuser A1-3
PLQ / 5PLQ
PLQR
PLQLT / 5PLQLT
PLQIMP
VPQ
KSD
1400 Series
1450 Series
SH Series
SHV Series
SHPC Series
SHFB Series
Flush Face Louvered Ceiling Diffuser with Rigid Fiberglass Backpan B1-99
5SH/CAD Series
SHRPLQ Series
7000
22
www.krueger-hvac.com
6200 Series
6290F
6300 Series
6390 Series
6400 Series
6490 Series
6500 Series
6600 Series
6690 Series
6790 Series
1100 Series
1190 Series
1240 Series
1240P Series
1240PE Series
23
OUR PRODUCTS
Linear Slot, Plenum Slot, and Round Diffusers
DesignFlo (DFL)
Architectural Linear Slot Diffuser E1-3
DFP
1900
1900BOOT
1900SQ Series
PTBS Series
PTBA Series
PTBT Series
11L
21L
31L
32L
41L
22
11R
21R
31R
32R
41R
42
PTBSS Series
PTBR Series
PFTBS
PFTBR
PTBSC Series
PTBSCDB Series
RM / RA Series
Round Cone Ceiling Diffuser G1-3
RM2PLQ / RM4PLQ
Round Plaque Ceiling Diffuser G1-17
24
www.krueger-hvac.com
RPN Series
RPNLP
CRN Series
CRNLP Series
CRNP Series
REGC5 Series
TAD
RADIAFLO
5000
5000HF
STERILFLO
STERILFLEX
CRFF Series
25
OUR PRODUCTS
Displacement Ventilation & Chilled Beams
AFA
Rectangular Low Velocity Supply Unit D3-9
AFB
AFC
AFD
AFE
AFF
AFP
AFQ
ABC
ASB
ABD
AHH
ABH
ADC
AHC
ACE
APT / APA
26
www.krueger-hvac.com
80 / 880 Series
Heavy Duty, Single/Double Deflection Supply Grille 1/2 Blade Spacing I1-25
Gang Operated Rear Louver Supply Grille, 3/4 Blade Spacing I1-25
5815
S80P
Heavy Duty, Fixed Deflection Return Grille, 1/2 or 3/8 Blade Spacing J1-35
AFS580 / AFS585
Architectural, Flixed Blade Return Grille, 1/2 or 3/4 Blade Spacing J1-60
AFCS80 / AFCS85
Architectural, Curved Blade Return Grille, 1/2 or 3/4 Blade Spacing J1-80
EG / EGC Series
Egg-crate Return Grille J1-94
5810
Linear Bar Supply Grille for Ceiling, Sidewall, Sill, or Floor K1-3 / K1-23
1700 Series
27
OUR PRODUCTS
Security, Industrial, and Duct Mounted Grilles & Registers
1310
Perforated Face Security Grille L1-3
13SD
1320
1330
1340
51350
1380 / 51380
680
6880
680MP
DPL / DPL2
DMG*R Series
DMG*U Series
DMD
600 Series
28
www.krueger-hvac.com
9S80HF Series
Stainless Steel, Fixed Blade Return with or without Hinge Face. P1-12
9S80P Series
9700 Series
91610 Series
91240 Series
91310 Series
9EGC5
29
OUR PRODUCTS
Product Finishes
Introduction
Krueger has a broad range of liquid and powder paint solutions available, as well as custom color matching to meet the needs of most air distribution applications. Additionally, we offer standard and custom color Aluminum anodizing for customers that may require the aesthetics and surface characteristics that these finishes offer. Applied in our state-of-the-art paint facilities, Krueger product finishes take full advantage of the most current, cutting-edge technology available. From standard paint finishes, custom color matching, antimicrobial powder paint coatings, and Aluminum anodizing, Krueger has a product finish that is right for you.
Method of Application
After assembly, products are washed, rinsed, pretreated with zirconium phosphate, and then rinsed again. They are then suspended from an anodic hook and dipped into a high performance electrocoating tank. Following electrocoating, products are dried and baked in a forced air oven at a peak temperature of 350F until cured.
Kruegers antimicrobial powder coat paints help reduce the undesirable effects of odors and stains caused by bacteria, mold, mildew, and fungi on the coating. They also resist fingerprints and smudges; staying cleaner between scheduled routine maintenance. When cleaning is necessary, they can be wiped down with a mild soap and water solution. Antimicrobials within the paint decrease microbial growth by disrupting the microorganisms when they make contact with the surface. A short period of time after contact, the bacteria levels begin to reduce to unmeasurable levels*. Even better, these coatings are environmentally friendly and are considered to be RoHS and REACH-compliant solutions. *DISCLAIMER: This product is formulated with antimicrobials to help suppress the growth of odor and stain-causing microorganisms on the coating. It is not intended as a substitute for good hygiene or to prevent foodborne or infectious illnesses.
Method of Application
After assembly, products go through a multi-staged wash and pretreat system, are oven dried, then coated with 2.0 to 3.0 mils of powder paint. The products then move through an oven and are baked at a temperature of 425F until fully cured.
30
www.krueger-hvac.com
Mill (01)
Alumican (10)
Black (35)
All finish types shown are not available with all products. Please see Kruegers Product Catalog or website for available finishes. Standard options are Mill or British White. For other paint selections or paint matching, setup fees may apply. All colors shown serve as a guide only. Please contact your local Krueger Representative for an actual sample. FILM PROPERTIES PROPERTY Film Thickness Gloss: 60-degrees Pencil Hardness Crosshatch Adhesion Impact Salt Spray Humidity Water Soak Conical Mandrel N/A ASTM D523-89 ASTM D3363-92A ASTM D3359-83 ASTM D2794-93 ASTM B117-9048 ASTM D2247-92 ASTM D870-92 ASTM D522 TEST METHOD STANDARD E-COAT VALUE 0.8 - 1.0 mils 50 - 85% HB - H Crosshatch 4B - 5B Direct: >100 in/lb Reverse: >80 in/lb 96 Hours > 500 Hours 250 Hours N/A STANDARD POWDER COAT VALUE 2.0 - 3.0 mils 60 - 70% H - 2H 5B N/A 1000 Hours 1000 Hours N/A 1/8 Conical Bend No Cracking Shows ANTIMICROBIAL POWDER COAT VALUE 2.0 - 3.0 mils 55 - 65% H - 2H 5B N/A 1000 Hours 1000 Hours N/A 1/8 Conical Bend No Cracking Shows
Off-White (01)
Olive (07)
Rust (08)
31
ASHRAE Member
ETL Listed
AHRI Listed
USGBC Member
32
www.krueger-hvac.com