You are on page 1of 306

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SUMMARY

SUMMARY
POWER ENTRY MODULES WITHOUT LINE FILTER Selector chart General Product Information 5 6 279

POWER ENTRY MODULES WITH LINE FILTER Selector chart General Product Information

83 84 279

BLOCK FILTERS Selector chart General Product Information

173 174 279

APPLIANCE COUPLERS Selector chart General Product Information

213 214 279

DISTRIBUTION UNITS Selector chart General Product Information

257 258 279

ACCESSORIES

272

GENERAL PRODUCT INFORMATION

279

SCHURTER INTERNATIONAL

297

INDEX BY TYPES

304

INDEX BY ORDER NUMBERS

305

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

A market leaders statement: The SCHURTER mission

Both now and in the future, our customers are guaranteed the best products world-wide; products which perfectly correspond to their individual needs. SCHURTER is permanently committed to the excellent quality of its products and business practices which are ecologically sound.
Hans-Rudolf Schurter, Schurter Holding AG

With the development, production and sales of active and passive components for electronic and electromechanical applications SCHURTER is a leading global industry partner. The SCHURTER Group leads the way in its four strategic business areas, using its innovative strength and cutting-edge technology to provide customers with intelligent practical solutions.

Leading the way in four strategic business areas


FUSES CIRCUIT BREAKERS FOR EQUIPMENT (CBE)

CONNECTORS

INPUT SYSTEMS

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER: Committed to business excellence

SCHURTER achieves its high level of overall quality as an enterprise by consistently implementing and observing the EFQM model (European Foundation for Quality Management). Quality and environmental management are interlinked, and form part of a circuit for monitoring visions, objectives and results. We are continually improving, using a wide range of quality control instruments. As a result, our customers recognise in us a reliable and longterm partner.

Pb

Schurter will supply all products lead free latest by 1.1.2006 according to the requirements of the EU-directive. Several products are already available in lead-free technology. Please get detailed information about the availability at www.schurter.ch/products/lead_free.asp

Certified Management Systems

CERTIFIED MANAGEMENT SYSTEMS ACCORDING TO ISO 9001:2000 AND 14001:1996.


REG.NR. 149056-02

General Member

ISO 9001:2000/ISO 14001:1996 Reg. Nr. 10540-05

ESPRIX AWARD WINNER 2002 Swiss Quality Award for Business Excellence

BUSINESS EXCELLENCE IN PRACTICE: STATISTICAL PROCESS CONTROL (SPC)


Process measurement product improvement provide innovation We use SPC to produce fault-free products and to maintain a complete control over our manufacturing processes. The three SPC mainstays of continuous process monitoring, early fault diagnosis and precise quality data contribute to a continuous improvement of all processes. SPC references such as cp, cpk and ppm provide our customers and partners with proof of our highly developed process capability. At SCHURTER, SPC is a permanent component in numerous production processes.

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER on EMC competence

HF measurement unit: At our EMC test laboratory we conduct standardised measurement methods (insertion loss, screening effect, etc.). We also analyse problem situations encountered by our customers and recommend the appropriate measures.

Suppressing interference effectively is a main requirement for any type of electrical equipment. And SCHURTER is your competent partner for the development and production of highquality EMC solutions. We are familiar with the standards relevant to your applications and apply them consistently. All you have to do is select the appropriate product from our wide range.

MAGNETIC FIELD
80 MHz 1000 MHz

FIELD
30 MHz 1000 MHz

IMMISSION

EMISSION

ESD SURGE BURST LINE


9 kHz 30 MHz

FLICKER HARMONICS

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

POWER ENTRY MODULES WITHOUT LINE FILTER

POWER ENTRY MODULES WITHOUT LINE FILTER

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART

POWER ENTRY MODULES WITHOUT LINE FILTER

Ratings Panel mounting

2.5 A / 250 VAC

10 A / 250 VAC Snap-in/screw-on front-/rear-side

10 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

10 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

Terminals for Product picture

PCB

Wires

Type Line switch Fuseholder Voltage selector Comment

CMF1; CMF2; CMF3 1-pole

KEB1 1-pole

KEB2 2-pole

DC11 1- or 2-pole

Line filter Protection class Catalogue page Ratings Panel mounting II; I 10 10 A / 250 VAC Screw-on rear-side PCB

KFB1 see page 90 I 13 10 A / 250 VAC Snap-in front-side Wires

KFB2 see page 93 I 15 10 A / 250 VAC Snap-in rear-side Wires

DC12 see page 96 I 17 10 A / 250 VAC Snap-in rear-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

DC21 2-pole

KM 2-pole 5 x 20, 1- or 2-pole with or without shield

GRM1 2-pole 5 x 20, 1- or 2-pole jumper optional Fuse on rear-side

PMM 1- or 2-pole jumper optional

Line filter Protection class Catalogue page

DC22 see page 100 I 19

KMF see page 104 I 21

GRM2 see page 108 I 24 I 27

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting

POWER ENTRY MODULES WITHOUT LINE FILTER


10 A / 250 VAC; 6 A / 250 VAC Snap-in/screw-on front-/rear-side Wires 10 A / 250 VAC; 6 A / 250 VAC Snap-in/screw-on front-/rear-side Wires 10 A / 250 VAC Screw-on front-side Wires 16 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

KD; KD-Bowdencable 2-pole 5 x 20 or 6.3 x 32, 1- or 2-pole step optional

KG; KG-Bowdencable 2-pole 5 x 20 or 6.3 x 32, 1- or 2-pole series-parallel

6145 2-pole

EC11 2-pole

with line switch for Bowdencable with line switch for Bowdencable with circuit breaker TA45

Line filter Protection class Catalogue page Ratings Panel mounting

CD see page 113 I 29 16 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

CG see page 118 I 32 10 A / 250 VAC Sandwich or rear-side

5145 see page 132 I 35 10 A / 250 VAC Snap-in front-side Wires

EC12 see page 137 I 39 10 A / 250 VAC Snap-in front-side PCB

Terminals for Product picture

PCB

Type Line switch Fuseholder Voltage selector Comment

EF11 2-pole

KP (Outlet); KP (Switch); KP (FH) 1- or 2-pole 5 x 20, 1- or 2-pole

Felcom 64 2-pole 5 x 20, 1- or 2-pole can be combined modularly

Switch; Inlet; Fuseholder; Outlet 2-pole 5 x 20, 1- or 2-pole Components for FELCOM

with circuit breaker TA45

Line filter Protection class Catalogue page

EF12 see page 140 I 42

KPF see page 87 I 46

Felcom 54 see page 129 I 50 I 53

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 10 A / 250 VAC

POWER ENTRY MODULES WITHOUT LINE FILTER


10 A / 250 VAC Snap-in front-side Wires 10 A / 250 VAC Snap-in/screw-on front-/rear-side Wires; PCB 10 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

Sandwich or rear-side

Terminals for Product picture

PCB

Type Line switch Fuseholder Voltage selector Comment

GSF1 5 x 20, optional, 1- or 2 pole Fuse on rear-side

GSF2 5 x 20, 1- or 2-pole Fuse on rear-side

KEA; KEA-Print 5 x 20, 1- or 2-pole step optional

6200; 6202; 6205; 6220 5 x 20, 1-pole; 5 x 20, 2-pole with internal connections; without internal connections

Line filter Protection class Catalogue page Ratings Panel mounting I 56 10 A / 250 VAC Screw-on front-/rear-side Wires I or II 60 10 A / 250 VAC Screw-on front-side Wires

KFA see page 149 I 63 10 A / 250 VAC Snap-in front-side Wires

5200 see page 160 I; II 67 10 A / 250 VAC Snap-in/screw-on front-/rear-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

4707 5 x 20, 1- or 2-pole

8842/8843 5 x 20, 1- or 2-pole

4719 5 x 20, 1-pole with or without neon indicator

KEC 5 x 20 or 6.3 x 32, 1- or 2-pole step optional

Line filter Protection class Catalogue page I 71 I or II 73 I 75

KFC see page 153 I 77

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 10 A / 250 VAC

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in/screw-on front-/rear-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

KE 5 x 20 or 6.3 x 32, 1- or 2-pole series-parallel

Line filter Protection class Catalogue page

CE see page 157 I 80

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CMF1, 2, 3

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

CMF1

CMF2

CMF3

C8

C8 polarized

C6

70 C

70 C

70 C

Description
- Panel mount: Screw-on mounting on PCB, from top or bottom - 2 Functions: Connector Protection class II [CMF1; CMF2]; Protection class I [CMF3], Line switch 1-pole - For PCB mounting - Alternative: polarized version or protection class I [CMF1] - Alternative: unpolarized version or protection class I [CMF2] - Alternative: protection class II version [CMF3]

Characteristics
- Easy mounting with center bolt and snapper or srewed on PCB or housing - Electrical connection done on the PCB - Bi-positioning of the switch from left or right side, Standard CMF with switch on right side - With or without rear-side insulation cover - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- line switch with other rocker marking - line switch on left of inlet

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 2.5 A / 250 VAC; 50 Hz 2.5 A / 125 VAC; 60 Hz > 2.3 kVAC between L-N > 2.8 kVAC between L/N-PE (1 min/50 Hz) Allowable operation temp. -25 C to 70 C Degree of protection from front side IP40 acc. to IEC 60529 Protection class [CMF1; CMF2] Suitable for appliances with protection class II acc. to IEC 61140 Protection class [CMF3] Suitable for appliances with protection class I acc. to IEC 61140 Terminals [CMF1; CMF2] PCB 1.6 mm Terminals [CMF3] PCB 1.6 mm Additional ground terminal Materials: Housing Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet [CMF1] C8 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 2.5 A, Protection class II Appliance-inlet /-outlet [CMF2] C8 polarized following IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 2.5 A, Protection class II Appliance-inlet /-outlet [CMF3] C6 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 2.5 A, Protection class I Line switch Rocker switch 1-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286

10

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CMF1, 2, 3
Dimensions

POWER ENTRY MODULES WITHOUT LINE FILTER

with insulation cover The size of the mounting cut-out can be selected as required.

Fixation on PCB or housing from below

Fixation on PCB or housing from above

1) self tapping screw

1) self tapping screw

Drilling diagrams CMF1 and CMF2 (C8)

CMF3 (C6)

d1 = 6.2 mm mounting from above d1 = 3.6 mm mounting from below PC Board 1.6 mm Dimensions without tolerance:<TAB/> 15 = 0.05 / > 15 = 0.10

d1 = 6.2 mm mounting from above d1 = 3.6 mm mounting from below PC Board 1.6 mm Dimensions without tolerance<TAB/> 15 = 0.05 / > 15 = 0.10

11

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CMF1, 2, 3
Variants
Standard CMF with switch on right side Order Number Appliance-inlet Mounting side CMF1.1031.12 CMF1.1131.12 CMF1.1011.12 CMF1.1111.12 CMF2.1031.12 CMF2.1131.12 CMF2.1011.12 CMF2.1111.12 CMF3.1032.12 CMF3.1033.12 CMF3.1034.12 CMF3.1132.12 CMF3.1133.12 CMF3.1134.12 CMF3.1012.12 CMF3.1013.12 CMF3.1014.12 CMF3.1112.12 CMF3.1113.12 CMF3.1114.12 C8 C8 C8 C8 C8 polarized C8 polarized C8 polarized C8 polarized C6 C6 C6 C6 C6 C6 C6 C6 C6 C6 C6 C6 50 Pcs from below from below from top from top from below from below from top from top from below from below from below from below from below from below from top from top from top from top from top from top

POWER ENTRY MODULES WITHOUT LINE FILTER

Cover

Ground terminal

Ground terminal direction

Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm Solder terminal 2.8 x 0.8 mm

angled to pin axis straight angled to pin axis straight angled to pin axis straight angled to pin axis straight

Packaging unit

12

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEB1

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Connector Protection class I, Line switch 1-pole - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter KFB1 - We recommend for new applications type DC11

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated

Other versions on request:


- unwired versions - line switch with other rocker marking - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1-pole, non-illuminated or illuminated red, acc. to IEC 61058-1 Technical details see page 286

Line switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

Dimensions Screw-on mounting

Snap-in mounting

13

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEB1
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

non-illuminated

illuminated

Variants
with internal connections Order Number Panel mounting 4302.0002 4302.0003 4302.0004 4302.0122 4302.0123 4302.0124 4302.0102 4302.0103 4302.0104 4302.0001 4302.0121 4302.0101 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on 50 Pcs red red 250 125 Panel thickness s [mm] 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 red red red red red red 250 250 250 125 125 125 Illumination Color Rated voltage 250 [V] Rated voltage 125 [V]

Packaging unit

Accessories

see page

277

14

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEB2

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Connector Protection class I, Line switch 2-pole - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter KFB2 - We recommend for new applications type DC11

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated

Other versions on request:


- unwired versions - line switch with other rocker marking - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 2-pole, non-illuminated or illuminated red or green, acc. to IEC 61058-1 Technical details see page 286

Line switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

Dimensions Screw-on mounting

Snap-in mounting

15

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEB2
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

non-illuminated

illuminated

Variants
with internal connections Order Number Panel mounting 4302.2102 4302.2103 4302.2104 4302.2142 4302.2143 4302.2144 4302.2002 4302.2003 4302.2004 4302.2101 4302.2141 4302.2001 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on 50 Pcs Panel thickness s [mm] 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 250 250 red green Illumination Rated voltage 125/250 [V] 250 250 250 250 250 250 Color red red red green green green

Packaging unit

Accessories

see page

277

16

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC11

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Connector Protection class I, Line switch 1- or 2-pole - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter DC12 - Substitute for type KEB1; KEB2

Characteristics
- Ultra-compact design - All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated - Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


snap-in, panel thickness 1 and 3 mm unwired versions solder terminals line switch with other rocker marking line switch 1-pole for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 50/60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-2 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1- or 2-pole, non-illuminated or illuminated red or green, acc. to IEC 61058-1 Technical details see page 286

Line switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

Dimensiomounting ns Screw-on

17

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC11

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting

Diagrams Line switch non-illuminated 2-pole

Line switch illuminated 2-pole

Line switch non-illuminated 1-pole

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load

Variants
with internal connections Order Number Panel mounting DC11.0021.201 DC11.0021.301 DC11.0021.401 DC11.0031.201 DC11.0031.301 DC11.0031.401 DC11.0001.203 DC11.0001.303 DC11.0001.403 DC11.0001.201 DC11.0001.301 DC11.0001.401 DC11.0021.001 DC11.0031.001 DC11.0001.003 DC11.0001.001 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on 50 Pcs Panel thickness s Line switch [mm] 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 2-pole red green Illumination Color red red red green green green

Packaging unit 18

Accessories

see page

278

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC21

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on mounting on PCB/ from rear-side - 2 Functions: Connector Protection class I, Line switch 2-pole - For PCB mounting - Alternative: version with line filter DC22 - Substitute for type KP (Switch)

Characteristics
- Ultra-compact design - All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated - With or without rear-side insulation cover - Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3 other rocker marking for protection class II without cover

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting ; Ground terminal: Quick connect terminals 4.8 x 0.8 mm Screw-on: max 3.5 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 2-pole, non-illuminated or illuminated red or green, acc. to IEC 61058-1 Technical details see page 286

Line switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

19

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC21
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

1) with cover 2) without cover

3) PE additionally as quick-connect terminal 4.8 x 0.8 mm

Diagrams Line switch illuminated 2-pole

Line switch non-illuminated 2-pole

1) Line 2) Load

1) Line 2) Load

Variants
Order Number DC21.0021.1111 DC21.0023.1111 DC21.0024.1111 Panel mounting Screw-on Screw-on Screw-on 20 Pcs Line switch 2-pole 2-pole 2-pole red green Illumination Color

Packaging unit

20

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KM

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

KM with shield

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Snap-in version from front side - 3 Functions: Connector Protection class I, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter KMF - With cover on rear-side

Characteristics
- Ultra-compact design. Small dimensions in front of and behind the panel - All single elements are already wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


fuse drawer 1-pole, plus spare fuse case fuse drawer 2-pole, with shorting bar in the neutral side N line switch 1-pole other rocker marking

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm , tin-plated Snap-in: 1/1.5/2/2.5 mm (all steps with one variant) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

21

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KM
Dimensions KM without shield

POWER ENTRY MODULES WITHOUT LINE FILTER

30,35
,5 R1

25,7 L N
47+0.10

46,8

-0.05

50

10,7

PE 3,2 26,15 S 0,05 2,5


28 +0.10

30,5

27,8

RO
-0.05

KM with shield

30,4
,5 R1

25,7 L N 46,8 47.8


+ 0.10 - 0.05

50

10,7

PE 10 26,2 S 0,05 2,5 27,8

30,5

0.

28.8

Diagrams Line switch and fuseholder 2-pole

with shield

1) Line 2) Load

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

22

www.schurter.com

ax
+ 0.10 - 0.05

.3

ax

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KM
Variants

POWER ENTRY MODULES WITHOUT LINE FILTER

Fuse drawer must be ordered separately (See accessories). Fingergrip and Extra Safe. The same drawer as used by type KEA. Order Number Fuseholder Line switch EMC-Shielding KM00.1205.11 KM01.1205.11 KM00.1105.11 KM01.1105.11 1-pole 1-pole 2-pole 2-pole 50 Pcs 2-pole 2-pole 2-pole 2-pole With EMC-shield and without line filter With EMC-shield and without line filter

Packaging unit

Accessories

see page

274

23

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM1

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Snap-in version from rear-side - 4 Functions: Connector Protection class I, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm on the rear-side, Voltage selector (Jumper) - Quick-connect terminals 4.8 x 0.8 mm - Alternative: version with line filter GRM2; GRM4

Characteristics
- Low mounting depth behind the panel Time saving "Lock and Shield" snap-in design for rear-panel mounting - All single elements are already wired except voltage selector - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - Voltage selector for two voltage ranges - Insulation cover on the rear-side - Especially suitable for use in switching power supplies - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


panel thickness 1.0 / 2 / 2.5 mm (max.) fuseholder 1-pole line switch 1-pole line switch with other rocker marking without housing and cover on the rear-side for protection class II (only without housing and cover on the rear-side) voltage selector with other marking

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50/60 Hz 10 A / 250 VAC; 50/60 Hz > 2.3 kVAC between L-N > 2.8 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm Solder terminal on request Solder terminals on voltage selector Snap-in: 1.5 mm (other on request) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector optional jumper, 2 digits

Allowable operation temp. Degree of protection Protection class Terminals

Panel thickness s Materials: Housing

24

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM1

POWER ENTRY MODULES WITHOUT LINE FILTER

Dimensions
19.1 23.3 26.05 13.35

L
42.4 38.4

L
45.4 40.9 +0.1 0

8.4

N
1.7 33.9 21.8 31.7

3.9

PE N
S0.05

34.20.05

R1

min. 8 *)

8.6

E = 31.7 mm for GRM1 with fuseholder E = 26.25 mm for GRM1 without fuseholder *) min. space to remove the fuseholder cover

Mounting instructions Step 1

Step 2

Step 3

Step 4

Place the socket in top edge of the panel cut-out.

Push the socket upwards.

Push the socket forward into the panel cut-out.

Release the socket. The component is self adjusting.

Diagrams Version: line switch and fuseholder 2-pole

Voltage selector

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per Pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

25

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM1
Variants
Basic version:: - Marking of the voltage selector 115/230 - with housing and cover on the rear-side Order Number Fuseholder GRM1.1160.013 GRM1.1161.023 GRM1.1180.013 GRM1.1181.023 2-pole 2-pole 20 Pcs

POWER ENTRY MODULES WITHOUT LINE FILTER

Voltage selector

Packaging unit

26

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

PMM

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

70 C

Description
- Panel mount: Snap-in version from rear-side - 4 Functions: Connector Protection class I, Outlet Protection class I, Line switch 1- or 2-pole, with or without voltage selector (Jumper) - Quick-connect terminals 4.8 x 0.8 mm

Characteristics
- Low mounting depth behind the panel - All single elements are already wired except voltage selector - Line switch non-illuminated - Voltage selector for two voltage ranges - Insulation cover on the rear-side - Especially suitable for use in switching power supplies - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


panel thickness 1.0 mm and 1.2 mm unwired (without pc-board), with pin-terminals wired (with pc-board), with flexible wires line switch with other rocker marking without cover voltage selector with other marking

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm Solder terminal on request Solder terminals on voltage selector Snap-in: 0.8/1.5 mm (other on request) Thermoplastic, black, UL 94V-2 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1 and F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1- or 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 optional jumper, 2 digits

Allowable operation temp. Degree of protection Protection class Terminals

Line switch

Voltage selector

Panel thickness s Materials: Housing

27

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

PMM

POWER ENTRY MODULES WITHOUT LINE FILTER

Dimensions
32 0.8
15.4 2

33.74

115 230

64.7

66.7

.05

63.5

4 +0

63.7 0.1

0 .0 5 0

4.8 x 0.8

15.5

R1
9.2

ma x.

1.2

21.3

7.5

13.44 26.2 S

S 0.05 7.2

1.2

32.2 0.1

5.2 0. 1

8.2 17.46 16.3

S = Panel thickness

1) solder lugs for 1.5mm2

Diagrams Version: line switch 2-pole

Voltage selector

1) voltage selector 2) appliance-inlet 3) appliance-outlet

Variants
Basic version: - Marking of the voltage selector 115/230 - with cover on the rear-side Order Number Panel thickness s Line switch [mm] 4307.3001 4307.3004 4307.3211 4307.3214 4307.4001 4307.4004 4307.4211 4307.4214 0.8 1.5 0.8 1.5 0.8 1.5 0.8 1.5 250 Pcs 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole

Voltage selector

Packaging unit

28

www.schurter.com

15.6 0.1

4+

.7 R3

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KD, KD-BOWDENCABLE

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Standard or Medical Fuse drawer

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 4 Functions: Connector Protection class I, Line switch [KD]; Line switch for bowdencable actuation [KD-Bowdencable] 1- or 2-pole [KD]; 2-pole [KD-Bowdencable], Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm, with or without voltage selector (step) - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter CD; CD-Bowdencable

Characteristics
- All single elements are already wired - The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


line switch, illuminated line switch with other rocker marking line switch 1-pole for protection class II for protection class II without voltage selector

Technical data
Ratings IEC [KD] Ratings IEC [KD-Bowdencable] Ratings UL/CSA [KD] Ratings UL/CSA [KD-Bowdencable] Dielectric strength 10 A / 250 VAC; 50 Hz 6 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz 8 A / 125 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm , tin-plated Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch [KD] Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line switch [KD-Bowdencable] Switch for Bowdencable 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector optional, step, 2-4 digits

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

29

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KD, KD-BOWDENCABLE
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting

Screw-on mounting

Panel cut-out for the actuating part

Snap-in mounting

Panel cut-out for the actuating part

30

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KD, KD-BOWDENCABLE
Diagrams without voltage selector

POWER ENTRY MODULES WITHOUT LINE FILTER

without voltage selector

with voltage selector

with voltage selector

1-pole

2-pole

1-pole

2-pole

Derating curves Fuses 5 x 20 mm 1-pole


Admissible power acceptance in Watt per pole Admissible power acceptance in Watt

Fuses 5 x 20 mm 2-pole (per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm 1-pole


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm 2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Variants
Fuse drawer must be ordered separately Bowden cable must be ordered separately Order Number Type Panel mounting KD13.1101.105 KD13.1101.107 KD13.1101.109 KD13.4101.105 KD13.4101.107 KD14.1101.105 KD14.1101.107 KD14.1101.109 KD14.4101.105 KD14.4101.107 KD14.4101.109 KD13.1101.151 KD13.4101.151 KD14.1101.151 KD14.4101.151 KD11.4199.105 KD11.4199.107 KD11.4199.109 KD14.4199.105 KD14.4199.107 KD14.4199.109 KD11.4199.151 KD14.4199.151 KD KD KD KD KD KD KD KD KD KD KD KD KD KD KD KD-Bowdencable KD-Bowdencable KD-Bowdencable KD-Bowdencable KD-Bowdencable KD-Bowdencable KD-Bowdencable KD-Bowdencable Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on 1.5 2 2.5 1.5 2 2.5

Panel thickness s [mm] 1.5 2 2.5 1.5 2 1.5 2 2.5 1.5 2 2.5

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 2-pole 2-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 1-pole 2-pole

Line switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch Rocker switch

Voltage selector max. 4 pos* without without without 2-4 digits 2-4 digits without without without 2-4 digits 2-4 digits 2-4 digits without 2-4 digits without 2-4 digits

Switch for Bow- without Switch for Bow- without Switch for Bow- without Switch for Bow- without Switch for Bow- without Switch for Bow- without Switch for Bow- without Switch for Bow- without

Can be used as 2-/3-position voltage selector - take only corresponding terminals

Packaging unit

20 Pcs [KD]; 10 Pcs [KD-Bowdencable]

Accessories

see page

277

31

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KG, KG-BOWDENCABLE

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Medical fuse drawer

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 4 Functions: Connector, Protection class I Line switch [KG]; Line switch for bowdencable actuation [KG-Bowdencable], 1- or 2-pole [KG]; 2-pole [KG-Bowdencable] Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm, Voltage selector - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter CG; CG-Bowdencable

Characteristics
- All single elements are already partial wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


line switch, illuminated line switch with other rocker marking line switch 1-pole for protection class II for protection class II

Technical data
Ratings IEC [KG] Ratings IEC [KG-Bowdencable] Ratings UL/CSA [KG] Ratings UL/CSA [KG-Bowdencable] Dielectric strength [KG] 10 A / 250 VAC; 50 Hz 6 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz 8 A / 125 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch [KG] Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line switch [KG-Bowdencable] Switch for Bowdencable 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

32

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KG, KG-BOWDENCABLE
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting

Screw-on mounting

Panel cut-out for the actuating part

Snap-in mounting

Panel cut-out for the actuating part

33

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KG, KG-BOWDENCABLE
Diagrams with partial internal connections

POWER ENTRY MODULES WITHOUT LINE FILTER

with partial internal connections

1-pole

2-pole

Derating curves 1-pole


Admissible power acceptance in Watt per pole Admissible power acceptance in Watt

2-pole (per pole)


Admissible power acceptance in Watt

1-pole
Admissible power acceptance in Watt per pole

2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperatur Ta C

Ambient air temperatur Ta C

Ambient air temperature Ta C

Variants
partial wired Fuse drawer and voltage selector insert must be ordered separately Bowdencable must be ordered separately Order Number Type Panel mounting Panel thickness s [mm] KG16.5101.105 KG16.5101.107 KG16.5101.109 KG10.6101.105 KG10.6101.107 KG10.6101.109 KG16.5101.151 KG10.6101.151 KG15.6199.107 KG15.6199.109 KG10.6199.105 KG10.6199.107 KG10.6199.109 KG15.6199.151 KG10.6199.151 KG KG KG KG KG KG KG KG KG-Bowdencable KG-Bowdencable KG-Bowdencable KG-Bowdencable KG-Bowdencable KG-Bowdencable KG-Bowdencable Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5

Fuseholder 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 1-pole 2-pole 1-pole 1-pole 2-pole 2-pole 2-pole 1-pole 2-pole

Packaging unit

20 Pcs [KG]; 10 Pcs [KG-Bowdencable]

Accessories

see page

53

34

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6145

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front side - 2 Functions: Connector Protection class I, circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version with line filter 5145 - We recommend for new applications type

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage release or remote trip release - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 1.5 kVAC between L/N-PE (1 min/50 Hz) -10 C to 55 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A

Circuit breaker

Dimensions

36

3,25

Detail a 2 1
6

29 +0,2

43

6,3 x 0,8 mm

R3 -0,5
+0,1 0

6,3 x 0,8 mm
M3 / 3,6

24,2 67,5* 13,5

* --- Version TA45 with undervoltage release

35

www.schurter.com

80 0,1

91,5

80

72

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6145
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

1) Line 2) Load

Packaging unit

20 Pcs

Accessories

see page

277

36

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6145
Table 1 Selection for type TA45 Order example

POWER ENTRY MODULES WITHOUT LINE FILTER


ABT W F 150 C0

5 3

P1

Line switch 2-pole, rocker actuated Quick connect terminal Other types on request
Diagram Thermal overload protection
without
P2 P1

with 1-pole
P2 P1

with 2-pole
P2 P1

Without illumination With illumination 220240 V 110120 V

ABC A02 A04

ABT A12 A14

ABD A32 A34

Colours Switch front Rocker

W B 6

black black black

white black

orange transp.

Rocker legend Surface Illustration Colour of print Surface Illustration Colour of print

F H K L

embossed / Relief printed / bedruckt printed / bedruckt printed / bedruckt

M white / weiss black / schwarz white / weiss P R

printed printed printed

black white black

OFF OFF

ON

I I

O O

ON l

Position of the rocker legend e.g F

Rated current: Without thermal overload protection: code C00

}I

n = 20 A

With thermal overload protection: rated current In (A)


In 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 Code J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 In 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 Code J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 In 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 Code J28 030 035 040 045 050 060 065 070 075 080 090 In 10,0 11,0 12,0 13,0 14,0 15,0 Code 100 110 120 130 140 150

Without release: code C0 Undervoltage release


P2 U< P1 P2 b U< P1 P2 ba U< P1

Remote trip release


P2 c P1

Code 2 3 4

Rated voltage Un 240 V AC 230 V AC 120 V AC

37

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6145
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10000
Type / Typ Rated current / Nennstrom TA45 In < 3 A 1-pole protected / 1-polig geschtzt 2-pole protected / 2-polig geschtzt Ambient temp. / Umgebungstemp. +23 C

POWER ENTRY MODULES WITHOUT LINE FILTER

Tripping characteristics In 3 15 A
[ min ] [ sec ] 10000
Type / Typ Rated current / Nennstrom TA45 I n 3... 15 A 1-pole protected / 1-polig geschtzt 2-pole protected / 2-polig geschtzt Ambient temp. / Umgebungstemp. +23 C

60 30 20 10 5 200 100 1 50 2000 1000 500

60 30 20 10 5 200 100 1 50 2000 1000 500

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

Tripping time / Auslsezeit

Multiple of rated current / Nennstrom-Vielfaches

[ x In ]

Tripping time / Auslsezeit

Multiple of rated current / Nennstrom-Vielfaches

[ x In ]

Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [C] Correction factor 10 0,89 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16

* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at + 40 C ambient temperature
1)

6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A

Order code (Order example) Type Order code TA 45 (2-pole rocker-switch without accessories) Wiring 0 Without 1 With 2 Special (on request)

6145 . A B T W F 1 5 0 C 0 see table 1

0 Without line filter 0 0 1 0 Without line filter

Please note that Schurter will establish an internal part number for logistical use in addition to the order code. The format of this internal part number is, for example 6145.0031.001

38

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC11

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

illuminated version

C20

70 C

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Connector Protection class I, Line switch 2-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version with line filter EC12

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated - Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- unwired versions - line switch with other rocker marking - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Rocker switch 2-pole, non-illuminated or illuminated red or green, acc. to IEC 61058-1 Technical details see page 286

Line switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

39

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC11
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

+ 0.05

36
+ 0.05 32.2 - 0.10

ca. 52 31.6

2.3 0.05

31.7 - 0.08

R
0.8

2.

6
0. 05

11.95 0.08

12.2 0.08

- 0.10 45.7 + 0.05

46.2 - 0.10

57 - 0.15

23.85

10.4

3.6
32.5 0.10 4.8

R6

3.3 0.05

26.6

6.4

Snap-in mounting

+0.05

36

ca. 52 31.6

2.3

0.05

31.7 -0.08
R 2. 6

0.

05

+0.05

+0.05 46.2 -0.10

45.7 -0.10

12.2

11.95 0.08

1.9

.7

R2

.8
+0.05

S 0.05 32.2 -0.10 26.6 4.8

2.15

R4

+0.05

32.5 -0.10

Diagrams Line switch non-illuminated

Line switch illuminated

1) Line 2) Load

1) Line 2) Load

40

www.schurter.com

46.5 -0.10

0.08

+0.05 50 -0.10

23.85

+0.05

. R2

95

5.25 0.05

R2
5

.8

4. 7

46.5 0.10
05 0.

2.
+ 0.05

95

57 0.10

+ 0.05

67

95 2.

R 2. 95
0
.0 5

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC11
Variants
with internal connections Order Number Panel mounting EC11.0001.201 EC11.0001.202 EC11.0021.201 EC11.0021.202 EC11.0031.201 EC11.0031.202 EC11.0001.301 EC11.0001.302 EC11.0021.301 EC11.0021.302 EC11.0031.301 EC11.0031.302 EC11.0001.401 EC11.0001.402 EC11.0021.401 EC11.0021.402 EC11.0031.401 EC11.0031.402 EC11.0001.002 EC11.0021.001 EC11.0021.002 EC11.0031.001 EC11.0031.002 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on 25 Pcs

POWER ENTRY MODULES WITHOUT LINE FILTER

Panel thickness s [mm] 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5

Illumination

Color

internal wired

red red green green

red red green green

red red green green red red green green

Packaging unit

Accessories

see page

277

41

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF11

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C20

70 C

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Connector Protection class I, circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version with line filter EF12

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage release or remote trip release - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- unwired versions

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 20 A / 125/250 VAC; 60 Hz > 1.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -10 C to 55 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A

Circuit breaker

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

42

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF11
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

76.7 ** 36 32.2
+ 0.05 - 0.10

ca. 72 10.6 41.7

2.3

0.05

31.7
R2 .6

+0.05 - 0.08

0.8

R
2. 95
05 0.

+0.05 - 0.15

+ 0.05 - 0.15

+0.05 - 0.15

100

79.2

0.10

11.95 0.08

0.08

40.55

78.7

12.2

05 0.

R
4.
10.4

2.

95

R 2.
5

8
0.05

R6

3.

6.4

32.5

0.10

** --- Version TA45 with undervoltage relaese

Snap-in mounting
76.7 **
+0.05

36

ca.72 10.6 41.7

2.3 0.05
R 2. 6

31.7 - 0.08

R 2. 95
0. 05
+ 0.05

78.7- 0.15

79.2-0.15

40.55

0.08

11.95

0.08

12.2

05 0.

95 2.
R

.7

8 2. R

R4

+ 0.05

S 0,05 26.55 4.8

2.15

1.9

32.2 - 0.10

+ 0.05

32.5 - 0.10

**--- Version TA45 with undervoltage release

Diagrams

1) Line 2) Load

Packaging unit

20 Pcs

Accessories

see page

277

43

www.schurter.com

79.5 - 0.15

83 -0.15

+0.05

+0.05

+ 0.05

5.25

3.3

0.05

26.55

4.8

79.5

90

90

0.10

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF11
Table 1 Selection for type TA45 Order example

POWER ENTRY MODULES WITHOUT LINE FILTER


ABT W F 150 C0

5 3

P1

Line switch 2-pole, rocker actuated Quick connect terminal Other types on request
Diagram Thermal overload protection
without
P2 P1

with 1-pole
P2 P1

with 2-pole
P2 P1

Without illumination With illumination 220240 V 110120 V

ABC A02 A04

ABT A12 A14

ABD A32 A34

Colours Switch front Rocker

W B 6

black black black

white black

orange transp.

Rocker legend Surface Illustration Colour of print Surface Illustration Colour of print

F H K L

embossed printed printed printed

M white black white P R

printed printed printed

black white black

OFF OFF

ON

I I

O O

ON l

Position of the rocker legend e.g F

Rated current: Without thermal overload protection: code C00

}I

n = 20 A

With thermal overload protection: rated current In (A)


In 10,0 11,0 12,0 Code 100 110 120 In 13,0 14,0 15,0 Code 130 140 150 In 16,0 17,0 18,0 Code 160 170 180 In 19,0 20,0 Code 190 200

Without release: code C0 Undervoltage release Remote trip release

P2 U<

P1

P2

b U<

P1

P2

ba U<

P1

P2

c P1

Code 2 3 4

Rated voltage Un 240 V AC 230 V AC 120 V AC

44

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF11
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In <3 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

POWER ENTRY MODULES WITHOUT LINE FILTER

Tripping characteristics In 3 < 18 A


[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In 3 A... < 18 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

Tripping characteristics In 18 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In 18 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

60 30 20 10 5 200 100 1 50 2`000 1`000 500

60 30 20 10 5 200 100 1 50 2`000 1`000 500

60 30 20 10 5 200 100 1 50 2`000 1`000 500

Ambient temp. Umgebungstemp.

Ambient temp. Umgebungstemp.

Ambient temp. Umgebungstemp.

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

Tripping time / Auslsezeit

Tripping time / Auslsezeit

Multiple of rated current Nennstrom-Vielfaches

[ x In ]

Multiple of rated current Nennstrom-Vielfaches

Tripping time / Auslsezeit

[ x In ]

Multiple of rated current Nennstrom-Vielfaches

[ x In ]

1) Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below:

* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached.

* Ambient temperature [C] 10 5 0 +23 +30 +40 +55

Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16

Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature
1)

6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A

Order code for EF11 (order example) Type Order code TA45 (2-pole rocker-switch without accessories) Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. The format of this internal part number is, for example EF11.3103.0010.01

EF11. A B T W F 1 5 0 C 0 . see table 1

00 1 0 . 01

Wiring 1 = wired Protection class 0 = Class I, housing black Panel mount 0 = Screw-on version 2 = Snap-in version s = 1,5 mm 3 = Snap-in version s = 2,0 mm 4 = Snap-in version s = 2,5 mm Terminals 1 = Quick connect terminals 6,3 x 0,8 mm 00 = without line filter

45

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KP01

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

Inlet with outlet

Inlet with line switch

Inlet with fuseholder (5x20 mm)

C14

70 C

70 C

Medical fuse drawer

Description
- Panel mount: Sandwich or rear-side - 2 Functions: Connector Protection class I, Outlet [KP (Outlet)]; Line switch [KP (Switch)]; Fuseholder for fuse-links 5 x 20 mm [KP (FH)] Protection class I [KP (Outlet)]; 1- and 2- pole [KP (Switch)]; 1- or 2-pole [KP (FH)] - For PCB mounting - Alternative: version with line filter KPF We recommend for new applications type DC21 [KP (Switch)]

Characteristics
- Panel mount from rear or "sandwich" between top and bottom/side to side panels PCB mount with snap-in or screw-on <BREAK/> feet (self tapping screws 3 x 8 mm) - All single elements are already wired - Line switch non-illuminated [KP (Switch)] - Fuse drawer meets requirements of medical standard IEC/EN 60601-1 [KP (FH)] The fuse drawer can only be opened with the aid of a tool [KP (FH)] The fuseholder is accessible from the equipment front [KP (FH)] - Insulation cover on the rear-side - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


for protection class II line switch, illuminated (only 2-pole version) line switch with other rocker marking for protection class II

Technical data
Ratings IEC Ratings UL/CSA [KP (Outlet); KP (FH)] Ratings UL/CSA [KP (Switch)] Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz 15 A / 250 VAC; 60 Hz > 2.3 kVAC between L-N > 2.8 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting Snap-in: 1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet [KP (Outlet)] C14 acc. to IEC/EN 60320-1 and F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Appliance-inlet /-outlet [KP C14 acc. to IEC/EN 60320-1, (Switch); KP (FH)] UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder [KP (FH)] 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C [KP (FH)] pole Power acceptance @ Ta > Admissible power acceptance at higher 23C [KP (FH)] ambient temperature see derating curves. Take note of the information on page 283 Line switch [KP (Switch)] Rocker switch 1- or 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

46

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KP01
Dimensions Screw on PCB mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in PCB mounting

A = for PCB-thickness 1.2/1.6/2.0/2.4 mm Additional quick connect terminal 4.8 x 0.8 mm

Additional quick connect terminal 4.8 x 0.8 mm s = panel thickness

Mounting holes for backside mounting

Sandwich mounting holes

Sandwich mounting holes

X = 48.4 at S = 1.5 and 2.5 X = 50.4 at S = 2.0 and 3.0

X = 48.4 at S = 1.5 and 2.5 X = 50.4 at S = 2.0 and 3.0

Drilling diagrams For 2-pole inlet/switch, 2-pole inlet/fuseholder and inlet/outlet

For 1-pole inlet/switch and 1-pole inlet/fuseholder S and X see mounting holes

Other dimensions as for 2-poles d1 = 6 0.05 for (snap-in) d1 = 3.6 (screw-on) d2 = 2 0.1 (screw-on) Dimensions without tolerance: 15 = 0.05; 15 = 0.1

47

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KP01
Mounting instructions

POWER ENTRY MODULES WITHOUT LINE FILTER

Stable snap feet requires minimal insertion force

Module must lay flat on the PCB when soldering

Screw-on mount uses self-tapping screws

Insertion from behind

"Sandwich" mounting with split enclosure panels

Diagrams

Inlet with outlet

Inlet with line switch

Inlet with fuseholder (5 x 20 mm)

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta in C

48

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KP01
Variants
Order Number KP01.1012.01 KP01.1013.01 KP01.1052.01 KP01.1053.01 KP01.1212.11 KP01.1112.11 KP01.1213.11 KP01.1113.11 KP01.1252.11 KP01.1152.11 KP01.1253.11 KP01.1153.11 KP01.1312.01 KP01.1412.01 KP01.1313.01 KP01.1413.01 KP01.1352.01 KP01.1452.01 KP01.1353.01 KP01.1453.01 Panel mounting Snap-in Snap-in Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on

POWER ENTRY MODULES WITHOUT LINE FILTER

Panel thickness s [mm] 2 3 2 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3

PCB [mm] 1.6 1.6 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.6 1.6 1.6 1.6 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.6 1.6 1.6 1.6 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4 1.2/1.6/2.0/2.4

Line switch

Fuseholder

Appliance outlet F F F F

1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole

Type KP without cover: KP01.XXXX.XX90

Packaging unit

50 Pcs

49

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 64

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

6421.005X.XX Appliance inlet Appliance outlet

6431.005X.XX Appliance inlet Switch Appliance outlet

6432.0X5X.XX Appliance inlet Fuseholder Switch Appliance outlet

C14

70 C

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Snap-in version from front side - 2 - 4 Functions: Connector Protection class I, Outlet Protection class I, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole - Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm - Alternative: version with line filter Felcom 54

Characteristics
- Modulare component selection - Individual components soldered on a printed circuit board - Plug removal necessary for fuse-link replacement Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Fully insulated from the rear - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- line switch with other rocker marking

Technical data
Ratings IEC Ratings UL/CSA Allowable operation temp. Protection class Terminals 10 A / 250 VAC; 50 Hz 10 A / 125/250 VAC; 60 Hz -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm , tinplated Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1 and F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, IEC 61058-1 Technical details see page 286

Panel thickness s Materials: Housing

Dimensions

Variants 6421.005X.XX Mounting hole: 53.6+0,2 x 27.6+0,2

Variants 6422.005X.XX Mounting hole: 46.7+0,2 x 27.6+0,2

50

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 64

POWER ENTRY MODULES WITHOUT LINE FILTER

Variants 6423.0X5X.XX Mounting hole: 65.5+0,2 x 27.6+0,2

Variants 6424.0X5X.XX Mounting hole: 57+0,2 x 27.6+0,2

Variants 6431.005X.XX Mounting hole: 80.1+0,2 x 27.6+0,2

Variants 6432.0X5X.XX Mounting hole: 90.6+0,2 x 27.6+0,2

Diagrams 6421 6422 6423 6424

1) Load 2 2) Load 1

1) Line 2) Load 1

1) Load 2 2) Load 1

1) Line 2) Load 1

6431

6432

1) Load 2 2) Load 1

1) Load 2 2) Load 1

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Packaging unit

10 Pcs

Accessories

see page

278

51

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 64
Ordering instructions

POWER ENTRY MODULES WITHOUT LINE FILTER

64 XX.0X5X.XX
Snap-in panel thickness 10 = 1,0 mm 12 = 1,2 mm 15 = 1,5 mm 20 = 2,0 mm 25 = 2,5 mm 30 = 3,0 mm Connection 51 = solder terminals 3,5 x 0,8 mm 53 = quick connect terminals 6,3 x 0,8 mm Fuseholder 5 x 20 mm 00 = without fuseholder 01 = 1-pole 02 = 2-pole Module combination 21 = Appliance inlet, outlet 22 = Appliance inlet, switch 23 = Appliance inlet, fuseholder, outlet 24 = Appliance inlet, fuseholder, switch 31 = Appliance inlet, outlet, switch 32 = Appliance inlet, fuseholder, outlet, switch Base model

52

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM COMPONENTS

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

Line switch

Appliance inlet

Appliance inlet with fuseholder

C14

70 C

70 C

Plug removal necessary for fuse replacement

Description
- Component: Snap-in version from front side - 1 Function [Switch; Inlet; Outlet]; 2 Functions [Fuseholder];: [Switch; Fuseholder; Outlet]; Line switch [Switch]; Connector [Inlet; Fuseholder]; Outlet [Outlet] 2-pole [Switch]; Protection class I [Inlet; Fuseholder; Outlet]; Fuseholder for fuse-links 5 x 20 mm [Fuseholder] 1- or 2-pole [Fuseholder] - For PCB mounting

Characteristics
- Individual components soldered on a printed circuit board [Fuseholder] - Line switch non-illuminated [Switch] - Plug removal necessary for fuse-link replacement [Fuseholder] Fuse drawer meets requirements of medical standard IEC/EN 60601-1 [Fuseholder] The fuseholder is accessible from the equipment front [Fuseholder] - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- other rocker marking

Technical data
Ratings IEC Ratings UL/CSA [Switch; Inlet; Outlet] Ratings UL/CSA [Fuseholder] Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing 10 A / 250 VAC; 50 Hz 15 A / 125/250 VAC; 60 Hz 10 A / 250 VAC; 60 Hz -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet [Inlet; Fuseholder] C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Appliance-inlet /-outlet [Outlet] F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder [Fuseholder] 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C [Fuseholder] pole Power acceptance @ Ta > Admissible power acceptance at higher 23C [Fuseholder] ambient temperature see derating curves. Take note of the information on page 283 Line switch [Switch] Rocker switch 2-pole, non-illuminated, IEC 61058-1 Technical details see page 286

Dimensions Line switch

53

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM COMPONENTS

POWER ENTRY MODULES WITHOUT LINE FILTER

Appliance inlet

Appliance outlet

Appliance inlet with fuseholder

54

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM COMPONENTS
Variants
Order Number 6050.5510 6050.5512 6050.5515 6050.5520 6050.5525 6050.5530 6150.5510 6150.5512 6150.5515 6150.5520 6150.5525 6150.5530 6250.5510 6255.5510 6250.5512 6255.5512 6250.5515 6255.5515 6250.5520 6255.5520 6250.5525 6255.5525 6250.5530 6255.5530 6650.4510 6650.4512 6650.4515 6650.4520 6650.4525 6650.4530 Type Switch Switch Switch Switch Switch Switch Connector Connector Connector Connector Connector Connector Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Fuseholder Outlet Outlet Outlet Outlet Outlet Outlet 50 Pcs

POWER ENTRY MODULES WITHOUT LINE FILTER

Panel thickness s [mm] 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1 1.2 1.2 1.5 1.5 2 2 2.5 2.5 3 3 1 1.2 1.5 2 2.5 3

Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Fuseholder

Appliance-inlet

Appliance outlet

C14 C14 C14 C14 C14 C14 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole C14 C14 C14 C14 C14 C14 C14 C14 C14 C14 C14 C14 F F F F F F

Packaging unit

55

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF1

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

Standard versions

Cover optional, see accessory

Blister try package

Pick and Place versions

C14

70 C

Description
- Panel mount: Sandwich or rear-side - 2 Functions: Connector Protection class I, with or without Fuseholder for fuselinks 5 x 20 mm on the rear-side 1- or 2-pole - For PCB mounting - Pick and place version

Characteristics
- PCB mount with snap-in or screw-on feet Suitable for automatic PCB assembling - All single elements are already wired - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - With or without rear-side insulation cover Blister tray meets ESD requirements - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Ground terminal with quick-connect terminal 6,3 x 0,8 mm - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting Snap-in: 1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder optional, 1- or 2 pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 3.15 W (1-pole)/ 2.5 W (2-pole) 23 C per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Dimensions rear-side mounting: without groove with insulation cover

A = 6 mm for standard versions A = 5 mm for pick and place versions

for mounting from rear-side

56

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF1

POWER ENTRY MODULES WITHOUT LINE FILTER

A = 6 mm for standard versions A = 5 mm for pick and place versions

for sandwich mounting

Drilling diagrams without fuseholder

with 1-pole fuseholder

with 2-pole fuseholder

Pick and Place versions without / with 1-pole or 2-pole fuseholder

d1 for snap-in mounting = 6 0.05 d1 for self-tapping screw = 3.6 0.1

d1 for snap-in mounting = 6 0.05 d1 for self-tapping screw = 3.6 0.1

d1 for snap-in mounting = 6 0.05 d1 for self-tapping screw = 3.6 0.1

1* only for protection class II

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

57

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF1
Variants
Order Number GSF1.0202.31 GSF1.0202.41 GSF1.0202.51 GSF1.0202.61 GSF1.0201.31 GSF1.0201.41 GSF1.0201.51 GSF1.0201.61 GSF1.1202.31 GSF1.1202.41 GSF1.1202.51 GSF1.1202.61 GSF1.1201.31 GSF1.1201.41 GSF1.1201.51 GSF1.1201.61 GSF1.2202.31 GSF1.2202.41 GSF1.2202.51 GSF1.2202.61 GSF1.2201.31 GSF1.2201.41 GSF1.2201.51 GSF1.2201.61 GSF1.0002.31 GSF1.0002.41 GSF1.0002.51 GSF1.0002.61 GSF1.0001.31 GSF1.0001.41 GSF1.0001.51 GSF1.0001.61 GSF1.1002.31 GSF1.1002.41 GSF1.1002.61 GSF1.1001.31 GSF1.1001.41 GSF1.1001.51 GSF1.1001.61 GSF1.2002.31 GSF1.2002.41 GSF1.2002.51 GSF1.2002.61 GSF1.2001.31 GSF1.2001.41 GSF1.2001.51 GSF1.2001.61 GSF1.3402.01 GSF1.4402.01 Mounting side Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich Sandwich rear-side rear-side

POWER ENTRY MODULES WITHOUT LINE FILTER

Panel mounting Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Metal snaps Metal snaps

Panel thickness s [mm] 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 3 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2 2.5 3 6 6

Fuseholder

Ground terminal Ground terminal direction 4.8 x 0.8 mm angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight

Package

1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight

1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole

angled to pin axis angled to pin axis angled to pin axis straight straight straight straight angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight angled to pin axis angled to pin axis Blister tray package Blister tray package

58

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF1
Variants
Order Number GSF1.5402.01 GSF1.0202.01 GSF1.0201.01 GSF1.1202.01 GSF1.1201.01 GSF1.2202.01 GSF1.2201.01 GSF1.0002.01 GSF1.0001.01 GSF1.1002.01 GSF1.1001.01 GSF1.2002.01 GSF1.2001.01 Mounting side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side rear-side

POWER ENTRY MODULES WITHOUT LINE FILTER

Panel mounting Metal snaps Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on

Panel thickness s [mm] 6 6 6 6 6 6 6 6 6 6 6 6 6

Fuseholder 2-pole

Ground terminal Ground terminal direction 4.8 x 0.8 mm angled to pin axis angled to pin axis straight

Package Blister tray package

1-pole 1-pole 2-pole 2-pole

angled to pin axis straight angled to pin axis straight angled to pin axis straight

1-pole 1-pole 2-pole 2-pole

angled to pin axis straight angled to pin axis straight

Insulation cover must be ordered separately. Order No. 0098.0078

Packaging unit

50 Pcs

59

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF2

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

C18

70 C

70 C

Description
- Panel mount: Snap-in version from front side - 2 Functions: Connector protection class I or II, Fuseholder for fuse-links 5 x 20 mm on the rear-side 1- or 2-pole - Quick-connect terminals 4.8 x 0.8 mm

Characteristics
- Two "locking" snappers reinforce connector against repeated or excessive pull out force during plug removal - All single elements are already wired - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- ground terminal, solder/quick-connect, 90 to connector axis

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 2.2 kVAC between L-N > 6 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm , Ground terminal: Solder terminals or quick connect terminals tin-plated Solder terminal on request Snap-in: 1/1.2/1.5/2/2.5/3 mm (other on request) (all steps with one variant) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 or C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I or II Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 3.15 W (1-pole)/ 2.5 W (2-pole) 23 C per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

Allowable operation temp. Degree of protection Protection class Terminals

Panel thickness s

Materials: Housing

60

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF2
Dimensions

POWER ENTRY MODULES WITHOUT LINE FILTER

punched / drilled

Line and neutral: Quick-connect terminal 4.8x0.8mm

Ground terminal: Quick connect terminal 4.8x0.8mm

Ground terminal: Quick-conect terminal 6.3x0.8mm

Mounting instructions

1) Main snappers for snap-in mounting 2) Additional safety snappers not in use

3) Additional safety snappers in use against excessive pull out force

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

61

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSF2
Variants
Order Number GSF2.1011.01 GSF2.1013.01 GSF2.2011.01 GSF2.2013.01 GSF2.1010.01 GSF2.2010.01 Protection class I I I I II II 50 Pcs

POWER ENTRY MODULES WITHOUT LINE FILTER

Fuseholder 1-pole 1-pole 2-pole 2-pole 1-pole 2-pole

Ground terminal Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm

Packaging unit

62

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEA, KEA-PRINT

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

KEA

KEA-Print

KEA

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 3 Functions [KEA]; 2 Functions [KEA-Print]: Connector Protection class I, Fuseholder for fuse-links 5 x 20 mm 1or 2-pole, [KEA]; with or without voltage selector [KEA]; (step switch) [KEA]; - Quick connect terminals 4.8 x 0.8 mm [KEA]; For PCB mounting [KEA-Print] Alternative: version with line filter KFA [KEA] -

Characteristics
- Available with or without internal connections [KEA] - All single elements are already wired [KEA-Print] - Plug removal necessary for fuse-link replacement The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- with solder terminals - fuse drawer with other voltage values - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm For PCB 1,6 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector [KEA] optional, step, 2-4 digits

Allowable operation temp. Degree of protection Protection class Terminals [KEA] Terminals [KEA-Print] Panel thickness s

Materials: Housing

63

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEA, KEA-PRINT
Dimensions Screw-on mounting type KEA

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting type KEA

Screw-on mounting type KEA-PRINT

Snap-in mounting type KEA-PRINT

Template grid 1/10" = 2.54 mm Drill. : 3/5/N = 1.3 + 0,1/0 Gnd = 1.6 + 0,1/0

Template grid 1/10" = 2.54 mm Drill : 3/5/N = 1.3 + 0,1/0 Gnd = 1.6 + 0,1/0

64

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEA, KEA-PRINT
Diagrams without internal connections voltage selector 4-positions 1-pole

POWER ENTRY MODULES WITHOUT LINE FILTER

without internal connections voltage selector 4-positions 2-pole

with internal connections voltage selector 3-positions 1-pole

with internal connections voltage selector 3-positions 2-pole

voltage selector 2-positions 1-pole

voltage selector 2-positions 2-pole

without voltage selector 1-pole

without voltage selector 2-pole

with internal connections 1-pole

with internal connections 2-pole

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

65

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEA, KEA-PRINT
Variants

POWER ENTRY MODULES WITHOUT LINE FILTER

Fingergrip and Extra-Safe Fuse drawer must be ordered separately internal connections, fuse drawer must be ordered separately Order Number Type Panel mounting Panel thickness s [mm] 4301.0522 4301.0523 4301.0524 4301.0022 4301.0023 4301.0024 4301.2062 4301.2063 4301.2064 4301.0502 4301.0503 4301.0504 4301.0002 4301.0003 4301.0004 4301.2042 4301.2043 4301.2044 4301.0521 4301.0021 4301.2061 4301.0501 4301.0001 4301.2041 4301.3212 4301.3213 4301.3214 4301.3202 4301.3203 4301.3204 4301.3211 4301.3201 KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA KEA-Print KEA-Print KEA-Print KEA-Print KEA-Print KEA-Print KEA-Print KEA-Print 50 Pcs Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 1-pole 2-pole

Voltage selector without without without 3 digits 3 digits 3 digits 3/4 digits 3/4 digits 3/4 digits without without without 3 digits 3 digits 3 digits 3/4 digits 3/4 digits 3/4 digits without 3 digits 3/4 digits without 3 digits 3/4 digits without without without without without without without without

internal wired

Packaging unit

Accessories

see page

277

66

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6200/02/05, 6220

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

Types 6200, 6205

Type 6220

Types 6200, 6205

1-pole Type 6202: for protection class II

2-pole

1-pole

C14

C18

70 C

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Screw-on version from front or rear side, snap-in version [6200; 6205; 6220]; Screw-on version [6202] from front side [6200; 6205; 6220]; from front or rear-side [6202] - 2 Functions: Connector Protection class I [6200; 6205; 6220]; Protection class II [6202], Fuseholder for fuse-links 5 x 20 mm 1-pole [6200; 6202; 6205]; 2-pole [6220] - Solder terminals or quick connect terminals Alternative: version with line filter 5200; 5220 [6200; 6220] -

Characteristics
- All single elements are already wired [6200; 6202; 6220] - Unwired [6205] - Plug removal necessary for fuse-link replacement [6200; 6202; 6205] The fuseholder is accessible from the equipment front [6200; 6202; 6205] With spare fuse compartment [6200; 6202; 6205] - Plug removal necessary for fuse-link replacement [6220] Fuse drawer meets requirements of medical standard IEC/EN 60601-1 [6220] The fuseholder is accessible from the equipment front [6220] - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Types for rivet mounting available upon request

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength [6200; 6205; 6220] 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) Dielectric strength [6202] > 4 kVAC between L-N (1 min/50 Hz) Allowable operation temp. -25 C to 70 C Degree of protection from front side IP40 acc. to IEC 60529 Protection class [6200; 6205; Suitable for appliances with protection 6220] class I acc. to IEC 61140 Protection class [6202] Suitable for appliances with protection class II acc. to IEC 61140 Terminals Solder terminals or quick connect terminals , tin-plated Panel thickness s [6200; 6205; Screw-on: max 6 mm 6220] Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Panel thickness s [6202] Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Materials: Housing Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet [6200; 6205; 6220] C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Appliance-inlet /-outlet [6202] C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class II Fuseholder [6200; 6202; 6205] 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Fuseholder [6220] 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole) 23 C [6200; 6202; 6205] Rated power acceptance @ Ta 5 x 20: 1.6 W 2-pole 23 C [6220] Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

67

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6200/02/05, 6220
Dimensions Screw-on mounting types 6200/02/05

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting types 6200/02/05

E: solder terminals<TAB/><TAB/>20.5 mm E: quick-connect terminals<TAB/>23.5 mm

E: solder terminals<TAB/><TAB/>22.5 mm E: quick-connect terminals<TAB/>25.5 mm S: 1.0/1.5/2.0/2.5/3.0 mm

Screw-on mounting type 6220

Snap-in mounting type 6220

E: solder terminals<TAB/><TAB/>20.5 mm E: quick-connect terminals<TAB/>23.5 mm

E: solder terminals<TAB/><TAB/>22.5 mm E: quick-connect terminals<TAB/>25.5 mm S: 1.0/1.5/2.0/2.5/3.0 mm

Diagrams 6200/05 6220

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

68

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6200/02/05, 6220
Variants

POWER ENTRY MODULES WITHOUT LINE FILTER

Socket and fuse drawer have to be ordered separately (see accessory) Order Number Protection class Panel mounting Panel thickness s [mm] 6200.4210 6200.4215 6200.4220 6200.4225 6200.4230 6200.4310 6200.4315 6200.4320 6200.4325 6200.4330 6200.4110 6200.4115 6200.4120 6200.4125 6200.4130 6200.2200 6200.2300 6200.2100 6202.2200 6202.2300 6202.2100 6205.4215 6205.4220 6205.4310 6205.4320 6205.4330 6205.4115 6205.4110 6205.4210 6205.4315 6205.4120 6205.4125 6205.4225 6205.4325 6205.4130 6205.2200 6205.2300 6205.2100 6205.4230 6220.5210 6220.5215 6220.5220 6220.5225 6220.5230 6220.5310 6220.5315 6220.5320 6220.5325 6220.5330 I I I I I I I I I I I I I I I I I I II II II I I I I I I I I I I I I I I I I I I I I I I I I I I I I Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in 1 1.5 2 2.5 3 1 1.5 2 2.5 3 1.5 2 1 2 3 1.5 1 1 1.5 2 2.5 2.5 2.5 3 1 1.5 2 2.5 3 1 1.5 2 2.5 3 1 1.5 2 2.5 3

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Terminals Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Solder terminals or quick connect terminals Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals or quick connect terminals Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm

internal wired

69

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6200/02/05, 6220
Variants
Order Number 6220.5110 6220.5115 6220.5120 6220.5125 6220.5130 6220.2200 6220.2300 6220.2100

POWER ENTRY MODULES WITHOUT LINE FILTER

Protection class Panel mounting I I I I I I I I 50 Pcs Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on

Panel thickness s [mm] 1 1.5 2 2.5 3

Fuseholder 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Terminals Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm see page 277

internal wired

Packaging unit

Accessories

70

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4707

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Screw-on version from front or rear-side - 2 Functions: Connector Protection class I, fuse-links 5 x 20 mm 1- or 2-pole - Solder terminals 3.8 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm

Characteristics
- All single elements are already wired - With slotted screw type fuseholder Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - IP40 (fuseholder IP65) - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Solder terminals 3.8 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 1.6 W (1-pole)/ 1.6 W (2-pole) 23 C per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Dimensions

E: solder terminals = 37.6 mm E: quick-connect terminals = 41.0 mm

71

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4707
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

Variants
Socket and fuse-carrier Order Number Terminals 4707.1000 4707.1300 4707.2000 4707.2300 Quick connect terminals 6.3 x 0.8 mm Solder terminals Quick connect terminals 6.3 x 0.8 mm Solder terminals 100 Pcs Fuseholder 1-pole 1-pole 2-pole 2-pole

Packaging unit

Accessories

see page

278

72

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

8842, 8843

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

C18

70 C

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Screw-on version from front side - 2 Functions: Connector protection class I or II, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole - Quick connect terminals 4.8 x 0.8 mm

Characteristics
- All single elements are already wired - With slotted screw type fuseholder Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 6 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 6 mm Mounting screw torque max 0.5 Nm Thermoplastic, black or gray, UL 94V-0 Appliance-inlet /-outlet C14 or C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I or II Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 1.6 W (1-pole)/ 1,2 W (2-pole) 23 C per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Dimensions

73

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

8842, 8843
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

Variants
Socket and fuse-carrier Order Number Protection class 0040.5012 0040.5000.2 0040.5001.2 0040.5015 I I I II 100 Pcs Fuseholder 1-pole 2-pole 2-pole 2-pole Case black black gray black

Packaging unit

74

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4719

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

with fuseholder

with fuseholder and neon indicator

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Snap-in version from front side - 3 Functions: Outlet shuttered Protection class I, Fuseholder for fuse-links 5 x 20 mm 1-pole, with or without neon indicator - Solder terminals 3.8 x 0.8 mm

Characteristics
- With internal connections, except neon indicator to allow for different configurations Neon indicator with wire terminals - With slotted screw type fuseholder Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Solder terminals 3.8 x 0.8 mm except neon indicator Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 1.6 W (1-pole) 23 C Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Dimensions
33.20 33.00 2.5

36.0

38,2

40.0 R1.0 MAX

37.20 37.00

'S'

PANEL CUT-OUT

75

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4719
Diagrams

POWER ENTRY MODULES WITHOUT LINE FILTER

version without neon indicator

Derating curves 1-pole


Admissible power acceptance in Watt Ambient air temperature Ta C

Variants
Order Number 4719.3300 4719.8300 4719.4300 4719.5300 4719.6300 4719.7300 4719.3310 4719.8310 4719.4310 4719.5310 4719.6310 4719.7310 Panel thickness s [mm] 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 100 Pcs Neon indication

Packaging unit

76

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEC

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Standard or Medical Fuse drawer

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 3 Functions: Connector Protection class I, Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm 1- or 2-pole, with or without voltage selector (step switch) - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter KFC

Characteristics
- Available with or without internal connections - The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- fuse drawer with other voltage values - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector optional, step, 2-4 digits

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

Dimensions Screw-on mounting

Snap-in mounting

77

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEC
Diagrams without internal connections voltage selector 4-positions 1-pole

POWER ENTRY MODULES WITHOUT LINE FILTER

without internal connections voltage selector 4-positions 2-pole

with internal connections voltage selector 4-positions 1-pole

with internal connections voltage selector 4-positions 2-pole

voltage selector 3-positions 1-pole

voltage selector 3-positions 2-pole

voltage selector 2-positions 1-pole

voltage selector 2-positions 2-pole

without voltage selector 1-pole

without voltage selector 2-pole

Derating curves Fuses 5 x 20 mm 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm 2-pole (per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm 1-pole


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm 2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

78

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KEC
Variants

POWER ENTRY MODULES WITHOUT LINE FILTER

Fuse drawer must be ordered separately (See accessories). Fingergrip and Extra-Safe Order Number Panel mounting Panel thickness s Fuseholder [mm] 4303.0032 4303.0212 4303.0033 4303.0093 4303.0213 4303.0034 4303.1032 4303.1092 4303.1212 4303.1093 4303.0002 4303.0062 4303.0182 4303.0003 4303.0063 4303.0183 4303.0004 4303.0184 4303.1002 4303.1062 4303.1182 4303.1003 4303.1063 4303.1183 4303.1064 4303.1184 4303.0031 4303.0091 4303.0211 4303.1031 4303.1091 4303.1211 4303.0001 4303.0061 4303.0181 4303.1001 4303.1061 4303.1181 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on 50 Pcs 1.5 1.5 2 2 2 2.5 1.5 1.5 1.5 2 1.5 1.5 1.5 2 2 2 2.5 2.5 1.5 1.5 1.5 2 2 2 2.5 2.5 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Voltage selector without 2 digits without 3/4 digits 2 digits without without 3/4 digits 2 digits 3/4 digits without 3/4 digits 2 digits without 3/4 digits 2 digits without 2 digits without 3/4 digits 2 digits without 3/4 digits 2 digits 3/4 digits 2 digits without 3/4 digits 2 digits without 3/4 digits 2 digits without 3/4 digits 2 digits without 3/4 digits 2 digits

internal wired

Packaging unit

Accessories

see page

277

79

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KE

POWER ENTRY MODULES WITHOUT LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Standard or Medical Fuse drawer

Description
- Panel mount: Screw-on version from front or rear side, snap-in version from front side - 3 Functions: Connector Protection class I, Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm 1- or 2-pole, Voltage selector (series-parallel) - Quick connect terminals 4.8 x 0.8 mm - Alternative: version with line filter CE

Characteristics
- Available with or without internal partial wired connections - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 3 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch

Allowable operation temp. Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

80

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KE
Dimensions Screw-on mounting

POWER ENTRY MODULES WITHOUT LINE FILTER

Snap-in mounting

Diagrams with partial wired internal connections

with partial wired internal connections

without internal connections

without internal connections

1-pole

2-pole

1-pole

2-pole

Derating curves Fuses 5 x 20 mm 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm 2-pole (per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm 1-pole


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm 2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Variants
Fuseholder and voltage selector insert must be ordered separately Order Number Panel mounting Panel thickness s Fuseholder [mm] KE15.1100.105 KE16.5100.105 KE16.5100.107 KE16.5100.109 KE10.2100.105 KE10.2100.107 KE10.2100.109 KE10.6100.105 KE10.6100.107 KE10.6100.109 KE15.1100.151 KE16.5100.151 KE10.2100.151 KE10.6100.151 Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on 1.5 1.5 2 2.5 1.5 2 2.5 1.5 2 2.5 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 2-pole 2-pole internal wired without connection partial wired partial wired partial wired without connection without connection without connection partial wired partial wired partial wired without connection partial wired without connection partial wired

81

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KE
Packaging unit
20 Pcs

POWER ENTRY MODULES WITHOUT LINE FILTER Accessories


see page 277

82

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

POWER ENTRY MODULES WITH LINE FILTER

POWER ENTRY MODULES WITH LINE FILTER

83

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART

POWER ENTRY MODULES WITH LINE FILTER

Ratings Panel mounting

1 - 10 A / 250 VAC Sandwich or rear-side

1 - 10 A / 250 VAC Screw-on front-side Wires

1 - 10 A / 250 VAC Screw-on front-side Wires

1 - 10 A / 250 VAC Snap-in/screw-on front-side Wires

Terminals for Product picture

PCB

Type Line switch Fuseholder Voltage selector Comment

KPF

KFB1 1-pole

KFB2 2-pole

DC12 1- or 2-pole

without shield

without Line filter Protection class Catalogue page Ratings Panel mounting

KP (Outlet) see page 46 I 87 1 - 10 A / 250 VAC Screw-on rear-side PCB

KEB1 see page 13 I 90 1 - 10 A / 250 VAC Snap-in front-side Wires

KEB2 see page 15 I 93

DC11 see page 17 I 96

10 A / 250 VAC; 0.5 - 10 A / 250 1 - 10 A / 250 VAC; 1 - 6 A / 250 Snap-in rear-side Wires Screw-on front-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

DC22 1- or 2-pole

KMF 2-pole 5 x 20, 1- or 2-pole

GRM2; GRM4 2-pole 5 x 20, 1- or 2-pole jumper optional without linefilter [GRM2], with shield; Fuse on rear-side

CD; CD-Bowdencable 2-pole 5 x 20 or 6.3 x 32, 1- or 2-pole step optional

without Line filter Protection class Catalogue page

DC21 see page 19 I 100

KM see page 21 I 104

GRM1 see page 24 I 108

KD see page 29 I 113

84

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting

POWER ENTRY MODULES WITH LINE FILTER


1 - 10 A / 250 VAC; 1 - 6 A / 250 1 - 10 A / 250 VAC Screw-on front-side Wires Screw-on front-side Wires 1 - 10 A / 250 VAC Screw-on front-side Wires 1 - 6 A / 250 VAC Snap-in front-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

CG; CG-Bowdencable 2-pole 5 x 20 or 6.3 x 32, 1- or 2-pole series-parallel

FKH; FKI 2-pole 5 x 20, 1-pole; 5 x 20, 2-pole

FKHD; FKID 2-pole 5 x 20, 1-pole; 5 x 20, 2-pole double stage filter

Felcom 54 2-pole 5 x 20, 1- or 2-pole can be combined modularly

without Line filter Protection class Catalogue page Ratings Panel mounting

KG see page 32 I 118 1 - 10 A / 250 VAC Screw-on front-side Wires I 122 12 - 16 A / 250 VAC Screw-on front-side Wires I 126 10 - 16 A / 250 VAC Screw-on front-side Wires

Felcom 64 see page 50 I 129 10 A / 250 VAC; 0.5 - 10 A / 250 Snap-in rear-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

5145 2-pole

EC12 2-pole

EF12 2-pole

GRF2; GRF4

with circuit breaker TA45

with circuit breaker TA45

without line filter [GRF2], with shield GRF2 see page 145 I 145

without Line filter Protection class Catalogue page

6145 see page 35 I 132

EC11 see page 39 I 137

EF11 see page 42 I 140

85

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 1 - 10 A / 250 VAC Screw-on front-side Wires

POWER ENTRY MODULES WITH LINE FILTER


1 - 10 A / 250 VAC Screw-on front-side Wires 1 - 10 A / 250 VAC Screw-on front-side Wires 1 - 10 A / 250 VAC Snap-in/screw-on front-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

KFA 5 x 20, 1- or 2-pole step optional

KFC 5 x 20 or 6.3 x 32, 1- or 2-pole step optional

CE 5 x 20 or 6.3 x 32, 1- or 2-pole series-parallel

5200; 5220 5 x 20, 1-pole; 5 x 20, 2-pole

without Line filter Protection class Catalogue page Ratings Panel mounting

KEA see page 63 I 149 1 - 10 A / 250 VAC Snap-in/screw-on front-side Wires

KEC see page 77 I 153 1 - 10 A / 250 VAC Screw-on front-side Wires

KE see page 80 I 157 16 A / 250 VAC Snap-in/screw-on front-side Wires

6200 see page 67 I 160

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

5110

KFS; KFX

C20F

without Line filter Protection class Catalogue page I 164 I 168 I 170

86

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KPF

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

Inlet with outlet

Standard- or Medical-Filter

Description
- Component: Snap-in version from rear-side - 1 Function: Line filter in standard and medical version - For PCB mounting - Only in combination with base-module type KP01

Characteristics
- Line filter for "backpack" mounting for modules types KP01 (snaps onto rear of KP01) - Electrical connection done on the PCB - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 70 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting Thermoplastic, black, UL 94V-0 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Materials: Housing

Dimensions

87

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KPF
Technical data of filter-components
Rated current Filter-Type [A] 1 2 4 6 8 10 1 2 4 6 8 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

POWER ENTRY MODULES WITH LINE FILTER

Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2x2 2x1 2 x 0.6 2 x 0.4 2 x 10 2x4 2x2 2x1 2 x 0.6 2 x 0.4 100 100 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 2.2

R [M ]

1 1 1 1 1 1

Diagrams Standard line filter

EMI filtering of equipment emissions

Layout to diagram A (KPFx.1.../KP01.xxxx.xx90)

Layout to diagram B (KPFx.1.../KP01.xxxx.xx90)

1) Line 2) Load

1) Line 2) Load

1) Minimum ground plane

1) Optimal ground plane - - - - differential mode _____ common mode

Attenuation loss
Standard version

1A

2A

4A

6A

8A

10 A

88

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KPF
Medical version

POWER ENTRY MODULES WITH LINE FILTER

1A

2A

4A

6A

8A

10 A

Variants
Order Number KPF1.1 KPF2.1 KPF4.1 KPF6.1 KPF8.1 KPF0.1 KPF1.3 KPF2.3 KPF4.3 KPF6.3 KPF8.3 KPF0.3 Rated current Filter-Type [A] 1 2 4 6 8 10 1 2 4 6 8 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Packaging unit

50 Pcs

89

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB1

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front side - 3 Functions: Connector Protection class I, Line switch 1-pole, Line-filter in standard version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter KEB1 - We recommend for new applications type DC12

Characteristics
All single elements are already wired Line switch non-illuminated With EMC-shield Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line switch

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Line filter

90

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB1
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 R [M ]

Diagrams

1) Line 2) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

6A

10 A

Medical version

4A

91

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB1
Variants
Order Number 4302.5001 4302.5002 4302.5003 4302.5004 4302.5005 Rated current Filter-Type [A] 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Packaging unit

10 Pcs

Accessories

see page

278

92

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB2

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 3 Functions: Connector Protection class I, Line switch 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter KEB2 - We recommend for new applications type DC12

Characteristics
All single elements are already wired Line switch non-illuminated With EMC-shield Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line switch

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Line filter

93

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB2
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load

94

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFB2
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

Variants
Order Number 4302.5311 4302.5312 4302.5313 4302.5314 4302.5315 4302.5331 4302.5333 4302.5335 4302.5337 4302.5339 Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Packaging unit

10 Pcs

Accessories

see page

277

95

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC12

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in or screw-on mounting from front side - 3 Functions: Connector Protection class I, Line switch 1- or 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter DC11 - Substitute for type KFB1; KFB2

Characteristics
Compact design with optimal shielding All single elements are already wired Line switch non-illuminated Universal line filter for standard applications Ideal for application with high transient loads Qualified for use in equipment according IEC/EN 60950 solder terminals other rocker marking line switch, illuminated Capacitance CX1 medical version M80 for protection class II

Other versions on request:

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1- or 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line switch

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s

Line filter

Materials: Housing

96

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC12
Dimensions Screw-on mounting

POWER ENTRY MODULES WITH LINE FILTER

Snap-in mounting

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 R [M ] 1 1 1 1 1 1 1 1 1 1

97

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC12
Diagrams Standard filter 1-pole

POWER ENTRY MODULES WITH LINE FILTER

Standard filter 2-pole

Medical filter 1-pole (M5)

Medical filter 2-pole (M5)

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

98

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC12
Variants
Order Number DC12.1102.103 DC12.2102.103 DC12.3102.103 DC12.4102.103 DC12.5102.103 DC12.1102.101 DC12.2102.101 DC12.3102.101 DC12.4102.101 DC12.5102.101 DC12.1102.003 DC12.2102.003 DC12.3102.003 DC12.4102.003 DC12.5102.003 DC12.1102.001 DC12.2102.001 DC12.3102.001 DC12.4102.001 DC12.5102.001 DC12.1202.103 DC12.2202.103 DC12.3202.103 DC12.4202.103 DC12.5202.103 DC12.1202.101 DC12.2202.101 DC12.3202.101 DC12.4202.101 DC12.5202.101 DC12.1202.003 DC12.2202.003 DC12.3202.003 DC12.4202.003 DC12.5202.003 DC12.1202.001 DC12.2202.001 DC12.3202.001 DC12.4202.001 DC12.5202.001 Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Panel mounting Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on

Line switch 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole see page 278

Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Packaging unit

Accessories

99

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC22

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on mounting on PCB from rear-side - 3 Functions: Connector Protection class I, Line switch 1- or 2-pole, Line filter in standard and medical version - For PCB mounting - Alternative: version without line filter DC21

Characteristics
Ultra-compact design All single elements are already wired Line switch non-illuminated or illuminated With EMC-shield Especially suitable for use in switching power supplies Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3 other rocker marking illuminated green medical version M80 Capacitance CX1

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting ; Ground terminal: Quick connect terminals 6.3 x 0.8 mm angled to pin axis Screw-on: max 4 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Rocker switch 1- or 2-pole, non-illuminated or illuminated red, acc. to IEC 61058-1 Technical details see page 286 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line switch

Allowable operation temp. Climatic category Degree of protection Protection class Terminals

Line filter

Panel thickness s Materials: Housing

100

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC22
Dimensions Screw-on mounting

POWER ENTRY MODULES WITH LINE FILTER

1) all pins

2) PE additionally as quick-connect terminal 6.3 x 0.8

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 R [M ] 1 1 1 1 1 1 1 1 1 1

101

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC22
Diagrams Standard filter 1-pole

POWER ENTRY MODULES WITH LINE FILTER

Standard filter 2-pole

Medical filter 1-pole (M5)

Medical filter 2-pole (M5)

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

102

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DC22
Variants
Order Number DC22.1111.111 DC22.2111.111 DC22.4111.111 DC22.6111.111 DC22.9111.111 DC22.1121.111 DC22.2121.111 DC22.4121.111 DC22.6121.111 DC22.9121.111 DC22.1123.111 DC22.2123.111 DC22.4123.111 DC22.6123.111 DC22.9123.111 DC22.1221.111 DC22.2221.111 DC22.4221.111 DC22.6221.111 DC22.9221.111 DC22.1223.111 DC22.2223.111 DC22.4223.111 DC22.6223.111 DC22.9223.111 Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Line switch 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Illumination

Color

red red red red red

Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

red red red red red

Packaging unit

103

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KMF

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Snap-in version from front side - 4 Functions: Connector Protection class I, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm - Alternative: version without line filter KM

Characteristics
- Ultra-compact design. Small dimensions in front of and behind the panel - All single elements are already wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Innovative EMC-shielding with flexible steel segments for an excellent contact - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- fuse drawer 1-pole, plus spare fuse case - fuse drawer 2-pole, with shorting bar in the neutral side N - other rocker marking

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Snap-in: 1/1.5/2/2.5 mm (all steps with one variant) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.4 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

104

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KMF
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

30,4 25,7
,5 R1

L N 46,8 47.8
+ 0.10 - 0.05

50

32

10,7

PE 40,4 S 0,05 2,5 27,8

30,5

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.4 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.4 47 47 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

105

www.schurter.com

0.
0.10 28.8 + - 0.05

ax

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KMF
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

106

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KMF
Variants

POWER ENTRY MODULES WITH LINE FILTER

Fuse drawer must be ordered separately (See accessories). Order Number Rated current Filter-Type [A] KMF1.1211.11 KMF1.1221.11 KMF1.1241.11 KMF1.1261.11 KMF1.1291.11 KMF1.1111.11 KMF1.1121.11 KMF1.1141.11 KMF1.1161.11 KMF1.1191.11 KMF1.1213.11 KMF1.1223.11 KMF1.1243.11 KMF1.1263.11 KMF1.1293.11 KMF1.1113.11 KMF1.1123.11 KMF1.1143.11 KMF1.1163.11 KMF1.1193.11 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 20 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole see page 277

Packaging unit

Accessories

107

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM2, GRM4

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

GRM2: only with shield, without line filter

GRM4: with shield and line filter

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in version from rear-side - 5 Functions: Connector Protection class I, Line switch 2-pole, with or without Fuseholder for fuse-links 5 x 20 mm, with or without voltage selector, with EMC-shield [GRM2]; Line filter in standard and medical version [GRM4] - Quick-connect terminals 4.8 x 0.8 mm - Alternative: version with line filter [GRM2] - Alternative: version without line filter GRM1; GRM2 [GRM4]

Characteristics
- Ultra-compact design Time saving "Lock and Shield" snap-in design for rear-panel mounting - All single elements are already wired - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - Voltage selector for two voltage ranges Innovative EMC- shielding with flexible steel segments for an excellent contact to the panel - Insulation cover on the rear-side - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


panel thickness 1.0 / 2 / 2.5 mm (max.) fuseholder 1-pole line switch 1-pole voltage selector with other marking

Technical data
Ratings IEC [GRM2] Ratings IEC [GRM4] Ratings UL/CSA [GRM2] Ratings UL/CSA [GRM4] Leakage current [GRM4] Dielectric strength 10 A @ Ta 40 C / 250 VAC; 50 Hz 0.5 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 10 A @ Ta 40 C / 125 VAC; 60 Hz 0.5 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm Solder terminal on request Solder terminals for voltage selector Snap-in: 1.5 mm (other on request) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector optional, jumper, 2 digits Line filter [GRM4] Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals

Panel thickness s Materials: Housing

108

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM2, GRM4
Dimensions GRM2

POWER ENTRY MODULES WITH LINE FILTER

49.5

26.0 13.4

42.3 2 12.5

38.4

45.4

3.9

PE

PE

13.45 0.1

6.5

R1
4.5

N 1.7
R 5

4.5

2.2 33.9 min. 8 *) E 8.6

S 0.05 6.9 0.1

34.2

0.05

24

31.7

E = 31.7 mm with fuseholder E = 26.25 mm without fuseholder *) Min. space to remove the fuseholder cover

GRM4

49.5 33.9

26.0 13.4

42.3 2 12.5 6.5

30.4 38.4

45.4

L 8.4

3.9

PE

PE

13.45 0.1

N 1.7

R1
5 4.

R5

4.5

2.2 31.7 min. 8 *) E 8.6

S 0.05 6.9
0.1

34.2

0.05

24

45.2

E = 31.7 mm with fuseholder E = 26.25 mm without fuseholder *) Min. space to remove the fuseholder cover

Technical data of filter-components


Rated current Filter-Type [A] 0.5 1 3 3 6 6 10 0.5 1 3 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 24 2 x 12 2 x 2.5 2 x 24 2 x 0.78 2 x 24 2 x 0.225 2 x 24 2 x 12 2 x 2.5 2 x 0.78 2 x 0.225 100 100 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 1 R [M ]

109

www.schurter.com

40.9

+0.1 0

40.9

8.4

+0.1 0

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM2, GRM4
Mounting instructions Step 1

POWER ENTRY MODULES WITH LINE FILTER

Step 2

Step 3

Step 4

Place the socket in top edge of the panel cut-out.

Push the socket upwards.

Push the socket forward into the panel cut-out.

Release the socket. The component is self adjusting.

Diagrams Voltage selector

GRM2

GRM4 Standard version

GRM4 Medical version

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per Pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C - - - - differential mode _____ common mode

Attenuation loss
Standard version

0.5 A

1A

3A

6A

10 A

110

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM2, GRM4
Medical version

POWER ENTRY MODULES WITH LINE FILTER

0.5 A

1A

3A

6A

10 A

111

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRM2, GRM4
Variants
Basic version: - Marking of the voltage selector 115/230 - with housing and cover on the rear-side Order Number Rated current Filter-Type [A] GRM2.1160.013 GRM2.1161.023 GRM2.1180.013 GRM2.1181.023 GRM4.4401.013 GRM4.4102.013 GRM4.4102.123 GRM4.4202.013 GRM4.4202.123 GRM4.4302.013 GRM4.4302.123 GRM4.4402.013 GRM4.4402.123 GRM4.4502.013 GRM4.4502.123 GRM4.4122.013 GRM4.4122.123 GRM4.4222.013 GRM4.4222.123 GRM4.4322.013 GRM4.4322.123 GRM4.4422.013 GRM4.4422.123 GRM4.4522.013 GRM4.4522.123 GRM4.5102.013 GRM4.5102.123 GRM4.5202.013 GRM4.5202.123 GRM4.5302.013 GRM4.5302.123 GRM4.5402.013 GRM4.5402.123 GRM4.5502.013 GRM4.5502.123 GRM4.5122.013 GRM4.5122.123 GRM4.5222.013 GRM4.5222.123 GRM4.5322.013 GRM4.5322.123 GRM4.5422.013 GRM4.5422.123 GRM4.5522.013 GRM4.5522.123 10 10 10 10 6 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 without without without without Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Fuseholder

Line switch 2-pole 2-pole

Voltage selector

2-pole 2-pole

2-pole 2-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Packaging unit for articles GRM4.xxxx.xxx.C: 20 Pcs

Packaging unit

20 Pcs [GRM2]; 120 Pcs [GRM4]

112

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CD, CD-BOWDENCABLE

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 5 Functions: Connector, Line switch [CD]; Line switch for bowdencable actuation [CD-Bowdencable], Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm, with or without voltage selector (step switch), Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm - Alternative: version without line filter KD; KD-Bowdencable

Characteristics
- All single elements are already wired - The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC [CD] Ratings IEC [CD-Bowdencable] Ratings UL/CSA [CD] Ratings UL/CSA [CD-Bowdencable] Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 6 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz 1 - 8 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch [CD] Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line switch [CD-Bowdencable] Switch for Bowdencable 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector [CD] optional, step, 2-4 digits Voltage selector [CD-Bowden- optional step, 2-4 digits cable] Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

113

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CD, CD-BOWDENCABLE
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Panel cut-out for the actuating part

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

114

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CD, CD-BOWDENCABLE
Diagrams Standard version with voltage selector

POWER ENTRY MODULES WITH LINE FILTER

Medical version with voltage selector

1) Line 2) Load

1) Line 2) Load x) External connection to be made by the customer

Derating curves Fuses 5 x 20 mm (1-pole)


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm (2-pole, per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm (1-pole)


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm (2-pole, per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C _____ common mode

Attenuation loss
Standard version

- - - - differential mode

1A

2A

4A

6A

10 A

115

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CD, CD-BOWDENCABLE
Medical version

POWER ENTRY MODULES WITH LINE FILTER

1A

2A

4A

6A

10 A

116

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CD, CD-BOWDENCABLE
Variants

POWER ENTRY MODULES WITH LINE FILTER

Fuse drawer must be ordered separately (See accessories). Fuse drawer and Bowdencable must be ordered separately. Order Number Type Rated current Filter-Type [A] CD11.1501.151 CD21.1501.151 CD31.1501.151 CD41.1501.151 CD61.1501.151 CD11.4501.151 CD21.4501.151 CD31.4501.151 CD41.4501.151 CD61.4501.151 CD14.1101.151 CD24.1101.151 CD34.1101.151 CD44.1101.151 CD64.1101.151 CD14.4101.151 CD24.4101.151 CD34.4101.151 CD44.4101.151 CD64.4101.151 CDG4.4101.151 CDA4.4101.151 CDC4.4101.151 CDE4.4101.151 CDL4.4101.151 CD11.4599.151 CD21.4599.151 CD31.4599.151 CD41.4599.151 CD14.4199.151 CD24.4199.151 CD34.4199.151 CD44.4199.151 CDG4.4199.151 CDA4.4199.151 CDC4.4199.151 CDE4.4199.151 CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug CD-Bowdenzug 10 Pcs 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 1 2 4 6 1 2 4 6 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole see page 277

Voltage selector

2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits

2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits 2-4 digits

Packaging unit

Accessories

117

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CG, CG-BOWDENCABLE

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 5 Functions: Connector, Line switch [CG]; Line switch for bowdencable actuation [CG-Bowdencable], Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm, Voltage selector (series-parallel), Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm - Alternative: version without line filter KG; KG-Bowdencable

Characteristics
- All single elements are already partial wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC [CG] Ratings IEC [CG-Bowdencable] Ratings UL/CSA [CG] Ratings UL/CSA [CG-Bowdencable] Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 6 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz 1 - 8 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch [CG] Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line switch [CG-Bowdencable] Switch for Bowdencable 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Voltage selector series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

118

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CG, CG-BOWDENCABLE
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Panel cut-out for the actuating part

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

119

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CG, CG-BOWDENCABLE
Diagrams Standard version with fuseholder 1- or 2-pole

POWER ENTRY MODULES WITH LINE FILTER

Medical version with fuseholder 2-pole

1) Line 2) Load

1) Line 2) Load

Derating curves Fuses 5 x 20 mm (1-pole)


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm (2-pole, per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm (1-pole)


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm (2-pole, per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C _____ common mode

Attenuation loss
Standard version

- - - - differential mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

120

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CG, CG-BOWDENCABLE
Variants

POWER ENTRY MODULES WITH LINE FILTER

Fuse drawer and voltage selector insert must be ordered separately. Fuse drawer, voltage selector insert and Bowdencable must be ordered separately. Order Number Type Rated current Filter-Type [A] CG16.5101.151 CG26.5101.151 CG36.5101.151 CG46.5101.151 CG66.5101.151 CG10.6101.151 CG20.6101.151 CG30.6101.151 CG40.6101.151 CG60.6101.151 CGG0.6101.151 CGA0.6101.151 CGC0.6101.151 CGE0.6101.151 CGL0.6101.151 CG10.6199.151 CG20.6199.151 CG40.6199.151 CG30.6199.151 CGA0.6199.151 CGG0.6199.151 CGC0.6199.151 CGE0.6199.151 CG CG CG CG CG CG CG CG CG CG CG CG CG CG CG CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug CG-Bowdenzug 10 Pcs 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 6 4 2 1 4 6 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Packaging unit

Accessories

see page

277

121

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKH, FKI

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 4 Functions: Connector Protection class I, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1-pole [FKH]; 2-pole [FKI], Line-filter in standard version [FKH]; Line filter in standard and medical version [FKI] - Quick connect terminals 6.3 x 0.8 mm - Alternative: Fuseholder 2-pole [FKH] - Alternative: Fuseholder 1-pole [FKI]

Characteristics
- Compact design with optimal shielding - All single elements are already wired - The fuseholder is accessible from the equipment front [FKH] Plug removal necessary for fuse-link replacement [FKH] - Plug removal necessary for fuse-link replacement [FKI] Fuse drawer meets requirements of medical standard IEC/EN 60601-1 [FKI] The fuseholder is accessible from the equipment front [FKI] - With EMC-shield [FKI] - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current [FKH] Leakage current [FKI] Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) standard < 0.25 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Admissible power acceptance at higher ambient temperature see derating curves. Take note of the information on page 283 Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Fuseholder [FKH]

Fuseholder [FKI]

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Power acceptance @ Ta > 23C

Line switch

Line filter [FKH]

Line filter [FKI]

122

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKH, FKI
Dimensions Case 50

POWER ENTRY MODULES WITH LINE FILTER

Case 45

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 R [M ] 1 1 1 1 1 1 1 1 1 1

123

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKH, FKI
Diagrams Standard Version

POWER ENTRY MODULES WITH LINE FILTER

1) Line 2) only FKI 3) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

124

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKH, FKI
Variants
Socket and fuse drawer Order Number Type 4304.4041 4304.4042 4304.4043 4304.4044 4304.4045 4304.4001 4304.4002 4304.4003 4304.4004 4304.4005 4304.4061 4304.4062 4304.4063 4304.4064 4304.4065 4304.4021 4304.4022 4304.4023 4304.4024 4304.4025 4304.4066 4304.4067 4304.4068 4304.4069 4304.4070 FKH FKH FKH FKH FKH FKH FKH FKH FKH FKH FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI FKI 10 Pcs

POWER ENTRY MODULES WITH LINE FILTER

Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Case 45 45 45 45 45 50 50 50 50 50 45 45 45 45 45 50 50 50 50 50 50 50 50 50 50

Materials: Housing Aluminum Aluminum Aluminum Aluminum Aluminum Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Aluminum Aluminum Aluminum Aluminum Aluminum Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel

Packaging unit

125

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKHD, FKID

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 4 Functions: Connector Protection class I, Fuseholder for fuse-links 5 x 20 mm 1pole [FKHD]; 2-pole [FKID], Line switch 2-pole, Line-filter in standard version [FKHD]; Line filter in standard and medical version [FKID] 2stage - [FKID] Quick connect terminals 6.3 x 0.8 mm Alternative: Fuseholder 1-pole [FKID]

Characteristics
Compact design with optimal shielding All single elements are already wired The fuseholder is accessible from the equipment front [FKHD] Plug removal necessary for fuse-link replacement [FKID] Fuse drawer meets requirements of medical standard IEC/EN 60601-1 [FKID] The fuseholder is accessible from the equipment front [FKID] - 2-stage line filter with increased attenuation [FKID] With EMC-shield [FKID] - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current [FKHD] Leakage current [FKID] Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) standard < 0.25 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on max 8 mm Mounting screw torque max 0.5 Nm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Admissible power acceptance at higher ambient temperature see derating curves. Take note of the information on page 283 Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Fuseholder [FKHD]

Fuseholder [FKID]

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s [FKHD] Panel thickness s [FKID] Materials: Housing

Power acceptance @ Ta > 23C

Line switch

Line filter [FKHD]

Line filter [FKID]

126

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKHD, FKID
Dimensions Case 45

POWER ENTRY MODULES WITH LINE FILTER

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 2 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Inductances Capacitance Capacity Cy1 Capacity Cy2 L [mH] CX [nF] [nF] [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2x4 68 68 68 68 68 68 1.5 1.5 1.5 1.5 1.5 1.5 1 1 1 1 1 1 R [M ] 1 1 1 1 1 1

Diagrams Standard Version

1) Line 2) only FKID 3) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

4A

6A

10 A

127

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FKHD, FKID
Medical version

POWER ENTRY MODULES WITH LINE FILTER

1A

2A

4A

6A

10 A

Variants
Order Number 4304.5042 4304.5043 4304.5044 4304.5045 4304.5001 4304.5002 4304.5003 4304.5004 4304.5005 4304.5061 4304.5062 4304.5063 4304.5064 4304.5065 4304.5021 4304.5022 4304.5023 4304.5024 4304.5025 4304.5067 Type FKHD FKHD FKHD FKHD FKHD FKHD FKHD FKHD FKHD FKID FKID FKID FKID FKID FKID FKID FKID FKID FKID FKID 10 Pcs Rated current Filter-Type [A] 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 2 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole Case 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 Materials: Housing Aluminum Aluminum Aluminum Aluminum Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Aluminum Aluminum Aluminum Aluminum Aluminum Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Nickel plated steel Aluminum

Packaging unit

128

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 54

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

5411.XX5X.XXX Appliance inlet Fuseholder Line filter

5431.X05X.XXX Appliance inlet Appliance outlet Switch Line filter

5432.XX5X.XXX Appliance inlet Appliance outlet Fuseholder Switch Line filter

C14

70 C

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in version from front side - 2 - 5 Functions: Connector Protection class I, Outlet, Line switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and medical version - Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter Felcom 64

Characteristics
- Modulare component selection - Individual components soldered on a printed circuit board - Plug removal necessary for fuse-link replacement Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Technical data of filter-components see blockfilter type 5500 - Fully insulated from the rear - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- line switch with other rocker marking

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 6 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 6 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

129

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 54
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Variants 5411.XX5X.XXX Mounting : 63+0,2 x 27.6+0,2

Variants 5421.X05X.XXX Mounting : 85.9+0,2 x 27.6+0,2

Variants 5423.XX5X.XXX Mounting : 96.4+0,2 x 27.6+0,2

Variants 5424.XX5X.XXX Mounting : 87.9+0,2 x 27.6+0,2

Variants 5431.X05X.XXX Mounting : 111.1+0,2 x 27.6+0,2

Variants 5432.XX5X.XXX Mounting : 121.6+0,2 x 27.6+0,2

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 1 2 4 6 6 6 Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Standard and medical version Standard and medical version 2x1 100 1 Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 11 2x4 2 x 1.6 2 x 0.7 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 1 1 1 1 R [M ]

130

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FELCOM 54
Diagrams 5411

POWER ENTRY MODULES WITH LINE FILTER

5421

5423

5424

1) Line 2) Load 1

1) Load 2 2) Load 1

1) Load 2 2) Load 1

1) Line 2) Load 1

5431

5432

1) Load 2 2) Load 1

1) Load 2 2) Load 1

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Packaging unit

10 Pcs

Accessories

see page

278

Ordering instructions

54 XX. X X XX. XX X
Type of line filter 1 = standard 3 = medical Snap-in panel thickness 10 = 1,0 mm 12 = 1,2 mm 15 = 1,5 mm 20 = 2,0 mm 25 = 2,5 mm 30 = 3,0 mm Connection 51 = solder terminals 3,5 x 0,8 mm 53 = quick connect terminals 6,3 x 0,8 mm Fuseholder 5 x 20 mm 0 = without fuseholder 1 = 1-pole 2 = 2-pole Line filter 1 = 1 Amp. 2 = 2 Amp. 4 = 4 Amp. 6 = 6 Amp. Module combination 11 = Appliance inlet, fuseholder 21 = Appliance inlet, appliance outlet 23 = Appliance inlet, fuseholder, appliance outlet 24 = Appliance inlet, fuseholder, switch 31 = Appliance inlet, appliance outlet, switch 32 = Appliance inlet, fuseholder, appliance outlet, switch Base model

131

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5145

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 3 Functions: Connector Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter 6145 - We recommend for new applications type

Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage release or remote trip release - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Circuit breaker

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Line filter

132

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5145
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

36

3,25

43 Detail a

13,5

Detail a 2 1

29 + 0,2

6,3 x 0,8 mm

0 R3 - 0,5

91,5

80

+ 0,1

6,3 x 0,8 mm

50,7 67,5*

M3 / 3,6

* --- Version TA45 with undervoltage release

Technical data of filter-components


Rated current Filter-Type [A] 1 2 3 4 6 8 10 15 1 2 6 8 10 15 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 11 2x4 2 x 2.5 2 x 1.6 2 x 0.7 2 x 0.6 2 x 0.4 2 x 0.1 2 x 11 2x4 2 x 0.7 2 x 0.6 2 x 0.4 2 x 0.1 47 47 47 47 47 47 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 R [M ]

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load

133

www.schurter.com

72 0

80

0,1

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5145
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

3A

4A

6A

8A

10 A

15A

Medical version

1A

2A

3A

4A

6A

8A

10 A

15A

Packaging unit

20 Pcs

134

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5145
Table 1 Selection for type TA45 Order example

POWER ENTRY MODULES WITH LINE FILTER


ABT W F 150 C0

5 3

P1

Line switch 2-pole, rocker actuated Quick connect terminal Other types on request
Diagram Thermal overload protection
without
P2 P1

with 1-pole
P2 P1

with 2-pole
P2 P1

Without illumination With illumination 220240 V 110120 V

ABC A02 A04

ABT A12 A14

ABD A32 A34

Colours Switch front Rocker

W B 6

black black black

white black

orange transp.

Rocker legend Surface Illustration Colour of print Surface Illustration Colour of print

F H K L

embossed / Relief printed / bedruckt printed / bedruckt printed / bedruckt

M white / weiss black / schwarz white / weiss P R

printed printed printed

black white black

OFF OFF

ON

I I

O O

ON l

Position of the rocker legend e.g F

Rated current: Without thermal overload protection: code C00

}I

n = 20 A

With thermal overload protection: rated current In (A)


In 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 Code J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 In 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 Code J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 In 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 Code J28 030 035 040 045 050 060 065 070 075 080 090 In 10,0 11,0 12,0 13,0 14,0 15,0 Code 100 110 120 130 140 150

Without release: code C0 Undervoltage release


P2 U< P1 P2 b U< P1 P2 ba U< P1

Remote trip release


P2 c P1

Code 2 3 4

Rated voltage Un 240 V AC 230 V AC 120 V AC

135

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5145
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10000
Type / Typ Rated current / Nennstrom TA45 In < 3 A 1-pole protected / 1-polig geschtzt 2-pole protected / 2-polig geschtzt Ambient temp. / Umgebungstemp. +23 C

POWER ENTRY MODULES WITH LINE FILTER

Tripping characteristics In 3 15 A
[ min ] [ sec ] 10000
Type / Typ Rated current / Nennstrom TA45 I n 3... 15 A 1-pole protected / 1-polig geschtzt 2-pole protected / 2-polig geschtzt Ambient temp. / Umgebungstemp. +23 C

60 30 20 10 5 200 100 1 50 2000 1000 500

60 30 20 10 5 200 100 1 50 2000 1000 500

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

Tripping time / Auslsezeit

Multiple of rated current / Nennstrom-Vielfaches

[ x In ]

Tripping time / Auslsezeit

Multiple of rated current / Nennstrom-Vielfaches

[ x In ]

Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [C] Correction factor 10 0,89 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16

* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at + 40 C ambient temperature
1)

6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A

Order code (Order example) Type Order code TA45 (2-pole rocker-switch without accessories) Wiring 0 Without 1 With Type of line filter 1 Standard 3 Medical Rated current of line filter 1 1 (A) 5 6 (A) 2 2 (A) 6 8 (A) 3 3 (A) 7 10 (A) 4 4 (A) 8 15 (A)

5145. A B T W F 1 5 0 C 0 see table 1

0 0 1

Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part number is, for example 5145.0031.001

136

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC12

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C20

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 3 Functions: Connector Protection class I, Line switch 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter EC11

Characteristics
- All single elements are already wired - Line switch non-illuminated Illuminated version on request - With EMC-shield - Ideal for application with high transient loads - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- line switch, illuminated - line switch with other rocker marking

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 12 - 16 A @ Ta 40 C / 250 VAC; 50 Hz 12 - 20 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details see page 286 Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line switch

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Line filter

137

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC12
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

37 0.15 32.2
+ 0.05 - 0.10

31.1 0.8

2.8 32.9
R 3. 05

0.08

+ 0.05

46.2- 0.10

57 - 0.15

57 0.10

12.2

12.55

5.5

10.9

4. 7

.8 R2

s
R6 .5
3.6

3.3 0.05 6.4

9.5

59.5

33.9 0.10

Technical data of filter-components


Rated current Filter-Type [A] 12 16 16 20 20 12 16 16 20 20 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 0.8 2 x 0.6 2 x 0.8 2 x 0.3 2 x 0.8 2 x 0.8 2 x 0.6 2 x 0.8 2 x 0.3 2 x 0.8 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 R [M ] 1 1 1 1 1 1 1 1 1 1

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

12 A

16 A

20 A

138

www.schurter.com

4.55 0.05

48 0.10
0. 05

+ + 0.05

23.85

68

47

3.

55

0. 05

R 55 3.

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EC12
Medical version

POWER ENTRY MODULES WITH LINE FILTER

12 A

16 A

20 A

Variants
Order Number EC12.3101.001 EC12.2101.001 EC12.1101.001 EC12.3101.002 EC12.2101.002 EC12.1101.002 EC12.3201.001 EC12.2201.001 EC12.1201.001 EC12.3201.002 EC12.2201.002 EC12.1201.002 Rated current [A] 12 16 20 12 16 20 12 16 20 12 16 20 20 Pcs Filter-Type Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) internal wired Line switch 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Packaging unit

139

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF12

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C20

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 3 Functions: Connector Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter EF11

Characteristics
- All single elements are already wired - Line switch non-illuminated Illuminated version on request Thermal overload protection Optional with undervoltage release or remote trip release - With EMC-shield - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 10 - 16 A @ Ta 40 C / 250 VAC; 50 Hz 10 - 20 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Circuit breaker

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Line filter

140

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF12
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

76,2* 37 0.15 10.6 41.2 0.8 2.8 32.9

32.2 - 0.10

0.05

R 3. 05
R 3. 55
0. 05

79.2 - 0.15

+0.05

90 0.10

12.2 0.08

40.55

0.0

12.55

5 3.5 R

.8 R2
4. 7
5.5 10.9 s 9.5 59.5 5.3

R6

3.2 0.05 6.4

3.6

33.9 0.10

* --- Version TA45 with undervoltage release

Technical data of filter-components


Rated current Filter-Type [A] 12 16 20 12 16 20 Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 0.8 2 x 0.6 2 x 0.3 2 x 0.8 2 x 0.6 2 x 0.3 100 100 100 100 100 100 2.2 2.2 2.2 R [M ] 1 1 1 1 1 1

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

12 A

16 A

20 A

141

www.schurter.com

4.55 0.05

.5

81 0.10

90 - 0.15

+0.05

80.05

101

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF12
Medical version

POWER ENTRY MODULES WITH LINE FILTER

12 A

16 A

20 A

Packaging unit

20 Pcs

142

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF12
Table 1 Selection for type TA45 Order example

POWER ENTRY MODULES WITH LINE FILTER


ABT W F 150 C0

5 3

P1

Line switch 2-pole, rocker actuated Quick connect terminal Other types on request
Diagram Thermal overload protection
without
P2 P1

with 1-pole
P2 P1

with 2-pole
P2 P1

Without illumination With illumination 220240 V 110120 V

ABC A02 A04

ABT A12 A14

ABD A32 A34

Colours Switch front Rocker

W B 6

black black black

white black

orange transp.

Rocker legend Surface Illustration Colour of print Surface Illustration Colour of print

F H K L

embossed printed printed printed

M white black white P R

printed printed printed

black white black

OFF OFF

ON

I I

O O

ON l

Position of the rocker legend e.g F

Rated current: Without thermal overload protection: code C00

}I

n = 20 A

With thermal overload protection: rated current In (A)


In 10,0 11,0 12,0 Code 100 110 120 In 13,0 14,0 15,0 Code 130 140 150 In 16,0 17,0 18,0 Code 160 170 180 In 19,0 20,0 Code 190 200

Without release: code C0 Undervoltage release Remote trip release

P2 U<

P1

P2

b U<

P1

P2

ba U<

P1

P2

c P1

Code 2 3 4

Rated voltage Un 240 V AC 230 V AC 120 V AC

143

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

EF12
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In <3 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

POWER ENTRY MODULES WITH LINE FILTER

Tripping characteristics In 3 < 18 A


[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In 3 A... < 18 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

Tripping characteristics In 18 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In 18 A 1 pole protected 1polig geschtzt 2 pole protected 2polig geschtzt +23 C

60 30 20 10 5 200 100 1 50 2`000 1`000 500

60 30 20 10 5 200 100 1 50 2`000 1`000 500

60 30 20 10 5 200 100 1 50 2`000 1`000 500

Ambient temp. Umgebungstemp.

Ambient temp. Umgebungstemp.

Ambient temp. Umgebungstemp.

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10

Tripping time / Auslsezeit

Tripping time / Auslsezeit

Multiple of rated current Nennstrom-Vielfaches

[ x In ]

Multiple of rated current Nennstrom-Vielfaches

Tripping time / Auslsezeit

[ x In ]

Multiple of rated current Nennstrom-Vielfaches

[ x In ]

Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table on the right side:
1)

* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached.
1)

* Ambient temperature [C] 10 5 0 +23 +30 +40 +55

Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16

Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature

6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A

Order code for EF12 (order example) Type Order code TA45 (2-pole rocker-switch without accessories) Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. The format of this internal part number is, for example EF12.xxxx.1110.01 Application note The rated current of the line filter must be equal or higher than the rated current of the circuit-breaker Other versions on request Rocker switch illuminated Wiring 1 = wired Protection class 0 = Class I, housing black Panel mount 0 = Screw-on version Terminals 1 = Quick connect terminals 6,3 x 0,8 mm Line filter version 1 = standard 2 = medical Line filter, rated current 1 = 20 A, 2 = 16 A, 3 = 12 A

EF12.

A B T W F 1 5 0 C 0 . see table 1

11 1 0. 0 1

144

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRF2, GRF4

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

GRF2: only with shield, without line filter

GRF4: with shield and line filter

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in version from rear-side - 2 Functions [GRF2]; 3 Functions [GRF4]: Connector Protection class I, with EMC-shield Line filter in standard and medical version [GRF4] - Quick-connect terminals 4.8 x 0.8 mm - Alternative: version with line filter [GRF2] - Alternative: version without line filter GRF2 [GRF4]

Characteristics
- Time saving "Lock and Shield" snap-in design for rear-panel mounting - All single elements are already wired - Innovative EMC- shielding with flexible steel segments for an excellent contact to the panel - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- with solder terminals - panel thickness 1.2 mm and 2.0 mm - with solder terminals

Technical data
Ratings IEC [GRF2] Ratings IEC [GRF4] Ratings UL/CSA [GRF2] Ratings UL/CSA [GRF4] Leakage current [GRF4] Dielectric strength 10 A @ Ta 40 C / 250 VAC; 50 Hz 0.5 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 15 A @ Ta 40 C / 125 VAC; 60 Hz 0.5 - 15 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm Solder terminal on request Snap-in: 1.2/1.5/2 mm Snap-in: 1.5 mm (other on request) Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line filter [GRF4]

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s [GRF2] Panel thickness s [GRF4] Materials: Housing

145

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRF2, GRF4

POWER ENTRY MODULES WITH LINE FILTER

Dimensions GRF2 GRF4

1) Terminal for earth screw M4 1) Terminal for earth screw M4 1) Terminal for earth screw M4 1) Terminal for earth screw M4

This area must be conductive for optimal shielding. Do not apply paint or coatings.

Technical data of filter-components


Rated current Filter-Type [A] 0.5 1 3 6 10 15 0.5 1 3 6 10 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 24 2 x 12 2 x 2.5 2 x 0.78 2 x 0.225 2 x 0.075 2 x 24 2 x 12 2 x 2.5 2 x 0.78 2 x 0.075 2 x 0.225 100 100 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 R [M ]

Mounting instructions

Step 1 Place the socket in the top edge of the panel cut-out

Step 2 Push the socket upwards

Step 3 Push the socket forward into the panel cut-out

Step 4 Release the socket. The component is self adjusting.

146

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRF2, GRF4
Diagrams Standard version

POWER ENTRY MODULES WITH LINE FILTER

Medical version

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

0.5 A

1A

3A

6A

10 A

15A

Medical version

0.5 A

1A

3A

6A

10 A

15A

147

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GRF2, GRF4
Variants
Order Number GRF2.0212.11 GRF2.0215.11 GRF2.0220.11 GRF2.0312.11 GRF2.0315.11 GRF2.0320.11 GRF4.0411.013 GRF4.0412.013 GRF4.0413.013 GRF4.0416.013 GRF4.0417.013 GRF4.0419.013 GRF4.0021.013 GRF4.0022.013 GRF4.0023.013 GRF4.0026.013 GRF4.0027.013 GRF4.0029.013 Rated Current IEC 10 10 10 10 10 10 0.5 1 3 6 10 15 0.5 1 3 6 10 10

POWER ENTRY MODULES WITH LINE FILTER

Rated Current Filter-Type UL 15 15 15 15 15 15 0.5 1 3 6 10 15 0.5 1 3 6 10 15 without without without without without without Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Panel thickness s [mm] 1.2 1.5 2 1.2 1.5 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

Additional ground terminal

Packaging unit for articles GRF4.xxxx.C: 20 Pcs

Packaging unit

100 Pcs [GRF2]; 200 Pcs [GRF4]

148

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFA

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

with voltage selector

without voltage selector

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Screw-on version from front side - 4 Functions: Connector Protection class I, Fuseholder for fuse-links 5 x 20 mm 1or 2-pole, with or without voltage selector (step switch), Line filter in standard and medical version - Quick connect terminals - Alternative: version without line filter KEA

Characteristics
- All single elements are already wired - Plug removal necessary for fuse-link replacement The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm With voltage selector: quick-connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per 23 C pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector optional, step, 3 digits Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals

Panel thickness s Materials: Housing

149

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFA
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

* with voltage selector ** without voltage selector

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 R [M ]

Diagrams Standard version with fuseholder 1- or 2-pole

Medical version with fuseholder 2-pole

without voltage selector

1) Line 2) Load

1) Line 2) Load

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per Pole

2-pole

Ambient air temperature Ta C

Ambient air temperature Ta C

150

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFA
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

151

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFA
Variants

POWER ENTRY MODULES WITH LINE FILTER

Fuse drawer must be ordered separately (See accessories). Order Number Rated current Filter-Type [A] 4301.6011 4301.6012 4301.6013 4301.6014 4301.6015 4301.6001 4301.6002 4301.6003 4301.6004 4301.6005 4301.5011 4301.5051 4301.5012 4301.5052 4301.5013 4301.5053 4301.5014 4301.5054 4301.5015 4301.5055 4301.5001 4301.5041 4301.5002 4301.5042 4301.5003 4301.5043 4301.5004 4301.5044 4301.5005 4301.5045 4301.6201 4301.6203 4301.6205 4301.5217 4301.5241 4301.5243 4301.5245 4301.5247 4301.5209 4301.5249 1 2 4 6 10 1 2 4 6 10 1 1 2 2 4 4 6 6 10 10 1 1 2 2 4 4 6 6 10 10 1 2 4 6 1 2 4 6 10 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Panel mounting Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Voltage selector

3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits

3 digits 3 digits 3 digits 3 digits 3 digits see page 278

Packaging unit

Accessories

152

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFC

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

with voltage selector

without voltage selector

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 4 Functions: Connector Protection class I, Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 20 mm, with or without voltage selector (step switch), Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm - Alternative: version without line filter KEC

Characteristics
- All single elements are already wired - The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector optional, step, 3 digits Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

153

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFC
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

Diagrams Standard version with voltage selector

Medical version with voltage selector

1) Line 2) Load

1) Line 2) Load x) External connection to be made by the customer

Derating curves Fuses 5 x 20 mm (1-pole)


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm (2-pole, per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm (1-pole)


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm (2-pole, per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

154

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFC
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

155

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFC
Variants

POWER ENTRY MODULES WITH LINE FILTER

Fuse drawer must be ordered separately (See accessories). Order Number Rated current Filter-Type [A] 4303.5011 4303.5012 4303.5013 4303.5014 4303.5015 4303.5031 4303.5032 4303.5033 4303.5034 4303.5035 4303.5001 4303.5002 4303.5003 4303.5004 4303.5005 4303.5021 4303.5022 4303.5023 4303.5024 4303.5025 4303.5221 4303.5223 4303.5225 4303.5227 4303.5229 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 1 2 4 6 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Voltage selector

3 digits 3 digits 3 digits 3 digits 3 digits

3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits 3 digits

Packaging unit

Accessories

see page

277

156

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CE

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Screw-on version from front side - 4 Functions: Connector, Fuseholder with interchangeable fuse drawer for Fuselinks 5 x 20 mm or 6.3 x 20 mm 1- or 2-pole, Voltage selector (series-parallel), Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm - Alternative: version without line filter KE

Characteristics
- All single elements are already partial wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuse drawer can only be opened with the aid of a tool The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick-connect terminals 4.8 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder 1- or 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm Rated power acceptance @ Ta 5 x 20: 2.5 W (1-pole)/ 2 W (2-pole) per 23 C pole 6.3 x 32: 3.15 W (1-pole)/ 2.5 W (2pole) per pole Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Voltage selector series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

157

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CE
Dimensions

POWER ENTRY MODULES WITH LINE FILTER

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 68 68 68 68 68 68 68 68 68 68 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 R [M ]

Diagrams Standard version

Medical version

1) Line 2) Load x) External connection to be made by customer

1) Line 2) Load x) External connection to be made by customer

Derating curves Fuses 5 x 20 mm (1-pole)


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

Fuses 5 x 20 mm (2-pole, per pole)


Admissible power acceptance in Watt

Fuses 6,3 x 32 mm (1-pole)


Admissible power acceptance in Watt per pole

Fuses 6,3 x 32 mm (2-pole, per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

Ambient air temperature Ta C

158

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

CE
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

Variants
Fuse drawer and voltage selector insert must be ordered separately. Order Number Rated current Filter-Type Fuseholder [A] CE16.5100.151 CE26.5100.151 CE36.5100.151 CE46.5100.151 CE66.5100.151 CE10.6100.151 CE20.6100.151 CE30.6100.151 CE40.6100.151 CE60.6100.151 CEA0.6100.151 CEC0.6100.151 CEE0.6100.151 CEG0.6100.151 CEL0.6100.151 1 2 4 6 10 1 2 4 6 10 2 4 6 1 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Packaging unit

Accessories

see page

277

159

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5200,5220

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

Type 5200, Fuseholder 1-pole with spare compartment

Typ 5220, Fuseholder 2-pole

Type 5200, Fuseholder 1-pole with spare compartment

C14

70 C

Plug removal necessary for fuse replacement

Description
- Panel mount: Snap-in or screw-on mounting from front side - 3 Functions: Connector Protection class I, Fuseholder for fuse-links 5 x 20 mm 1pole [5200]; 2-pole [5220], Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter 6200; 6220

Characteristics
- All single elements are already wired - Plug removal necessary for fuse-link replacement Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Fuseholder [5200] 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Fuseholder [5220] 2-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Rated power acceptance @ Ta 5 x 20: 2 W (1-pole) 23 C [5200] Power acceptance @ Ta > Admissible power acceptance at higher 23C ambient temperature see derating curves. Take note of the information on page 283 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

160

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5200,5220
Dimensions Screw-on mounting type 5200

POWER ENTRY MODULES WITH LINE FILTER

Snap-in mounting type 5200

Screw-on mounting type 5220

Snap-in mounting type 5220

Technical data of filter-components


Rated current Filter-Type [A] 1 2 4 6 8 10 1 2 4 6 8 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.6 2 x 0.4 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.6 2 x 0.4 47 47 47 47 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 R [M ]

161

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5200,5220
Diagrams 5200 Standard version

POWER ENTRY MODULES WITH LINE FILTER

5200 Medical version

5220 Standard version

5220 Medical version

1) LIne 2) Load

1) LIne 2) Load

1) Line 2) Load

1) Line 2) Load

Derating curves 1-pole


Admissible power acceptance in Watt Admissible power acceptance in Watt per pole

2-pole (per pole)

Ambient air temperature Ta C

Ambient air temperature Ta C - - - - differential mode _____ common mode

Attenuation loss
Standard version

1A

2A

4A

6A

8A

10 A

Medical version

1A

2A

4A

6A

8A

10 A

162

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5200,5220
Variants

POWER ENTRY MODULES WITH LINE FILTER

Socket and fuse drawer have to be ordered separately (see accessory) Order Number Rated current Filter-Type Panel mounting [A] 5200.1043.1 5200.0843.1 5200.0643.1 5200.0443.1 5200.0243.1 5200.0143.1 5200.1023.1 5200.0823.1 5200.0623.1 5200.0423.1 5200.0223.1 5200.0123.1 5200.1043.3 5200.0843.3 5200.0643.3 5200.0443.3 5200.0243.3 5200.0143.3 5200.1023.3 5200.0823.3 5200.0623.3 5200.0423.3 5200.0223.3 5200.0123.3 5220.1043.1 5220.0843.1 5220.0643.1 5220.0443.1 5220.0243.1 5220.0143.1 5220.1023.1 5220.0823.1 5220.0623.1 5220.0423.1 5220.0223.1 5220.0123.1 5220.1043.3 5220.0843.3 5220.0643.3 5220.0443.3 5220.0243.3 5220.0143.3 5220.1023.3 5220.0823.3 5220.0623.3 5220.0423.3 5220.0223.3 5220.0123.3 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 8 6 4 2 1 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on

Fuseholder 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 1-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole

Packaging unit

Accessories

see page

278

163

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5110

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in or screw-on mounting from front side - 2 Functions: Connector Protection class I, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm

Characteristics
- Ultra-compact design - All single elements are already wired - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Capacitance CX1

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 5 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line filter

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

Dimensions Screw-on mounting


48.4 40 9.5 40.9 5.2 7.9 21 29 +0.2 0

23

ax R 3m

3.2 6.3 x 90

2.7

4.1

40 0.1

164

www.schurter.com

21 +0.2 0
.6 3

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5110

POWER ENTRY MODULES WITH LINE FILTER

Snap-in mounting
29 36 9.5 41.2 5 7.9 21 4.1
+0.2 0

23

ax m R3

3.5

Technical data of filter-components


Rated current Filter-Type [A] 1 2 3 4 6 8 10 15 1 2 3 4 6 8 10 15 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 11 4 2.5 1.6 0.7 0.6 0.4 0.1 11 4 2.5 1.6 0.7 0.6 0.4 0.1 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 1 1 1 1 1 1 1 1 R [M ]

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load

165

www.schurter.com

21 +0.2 0

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5110
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

1A

2A

3A

4A

6A

8A

10 A

15A

Medical version

1A

2A

3A

4A

6A

8A

10 A

15A

166

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5110
Variants
Order Number 5110.0143.1 5110.0243.1 5110.0343.1 5110.0443.1 5110.0643.1 5110.0843.1 5110.1043.1 5110.1543.1 5110.0133.1 5110.0233.1 5110.0333.1 5110.0433.1 5110.0633.1 5110.0833.1 5110.1033.1 5110.1533.1 5110.0143.3 5110.0243.3 5110.0343.3 5110.0443.3 5110.0643.3 5110.0843.3 5110.1043.3 5110.1543.3 5110.0133.3 5110.0233.3 5110.0333.3 5110.0433.3 5110.0633.3 5110.0833.3 5110.1033.3 5110.1533.3 Rated current Filter-Type [A] 1 2 3 4 6 8 10 15 1 2 3 4 6 8 10 15 1 2 3 4 6 8 10 15 1 2 3 4 6 8 10 15 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Panel mounting Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on

Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

Packaging unit

Accessories

see page

278

167

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFS, KFX

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

Description
- Panel mount: Screw-on version from front side - 2 Functions: Connector Protection class I, Line-filter in standard version - Quick connect terminals 6.3 x 0.8 mm

Characteristics
Compact design with optimal shielding All single elements are already wired Universal line filter for standard applications [KFS] Universal line filter for standard applications [KFX] With enhanced surge withstand voltage [KFX] - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) > 2.5 kV between L-N (CX2) > 5 kV between L/N-PE (CX1, CX2) > 4 kV between L-N (CX1) > 5 kV between L/N-PE (CX1, CX2) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line filter

Surge withstand [KFS] Surge withstand [KFX] Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing

Dimensions

168

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

KFS, KFX
Technical data of filter-components
Rated current Filter-Type [A] 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version

POWER ENTRY MODULES WITH LINE FILTER

Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2

R [M ]

Diagrams Standard version

1) Line 2) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

4A

6A

10 A

Variants
Order Number 4300.5051 4300.5052 4300.5053 4300.5054 4300.5055 4300.5061 4300.5062 4300.5063 4300.5064 4300.5065 Type KFS KFS KFS KFS KFS KFX KFX KFX KFX KFX 10 Pcs Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version CX Class X2 X2 X2 X2 X2 X1 X1 X1 X1 X1

Packaging unit

Accessories

see page

278

169

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

C20F

POWER ENTRY MODULES WITH LINE FILTER


Actual information about approvals can be found on http://www.schurter.com/approvals

C20

70 C

Standard- or Medical-Filter

Description
- Panel mount: Snap-in or screw-on mounting from front side - 2 Functions: Connector Protection class I, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm

Characteristics
Compact design with optimal shielding All single elements are already wired Version with class X1 and X2 (standard version) capacitors Universal line filter for standard applications Designed for standard and medical applications - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- medical version M80 - Other rated currents

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 16 A @ Ta 40 C / 250 VAC; 50 Hz 20 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N (CX1, CX2) > 2.7 kVDC between L/N-PE (CX1, CX2) Test voltage (2 sec) > 2.5 kV between L-N (CX2) > 4 kV between L-N (CX1) > 5 kV between L/N-PE (CX1, CX2) voltage (1.2/50 s) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Line filter

Surge withstand

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s

Materials: Housing

170

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

C20F
Dimensions Screw-on mounting

POWER ENTRY MODULES WITH LINE FILTER

Snap-in mounting

Technical data of filter-components


Rated current Filter-Type [A] 16 16 Standard Version Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 0.3 2 x 0.3 100 100 2.2 R [M ] 1 1

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load

171

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

C20F
Attenuation loss
Standard version

POWER ENTRY MODULES WITH LINE FILTER


- - - - differential mode _____ common mode

20 A

Medical version

20 A

Variants
Order Number C20F.0011 C20F.0013 C20F.0001 C20F.0003 C20F.0012 C20F.0014 C20F.0002 C20F.0004 Rated Current IEC 16 16 16 16 16 16 16 16 20 Pcs Rated Current Filter-Type UL 20 20 20 20 20 20 20 20 Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Panel mounting Snap-in Snap-in Screw-on Screw-on Snap-in Snap-in Screw-on Screw-on Capacitor X2 X1 X2 X1 X2 X1 X2 X1 see page 278

Packaging unit

Accessories

172

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

BLOCK FILTERS

BLOCK FILTERS

173

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART

BLOCK FILTERS

Ratings Panel mounting

1 - 6 A / 250 VAC PCB mounted from top PCB

0.5 - 6,5 A / 250 VAC PCB mounted from top PCB

0.5 - 6,5 A / 250 VAC PCB mounted from top PCB

2 - 16 A / 250 VAC PCB mounted from top PCB

Terminals for Product picture

Type Filter-Type Attenuation Filter stage Application

5500 Standard and medical version Standard 1 General purpose

FPP-01 Standard and medical version Standard 1 General purpose

FPP-02 Standard and medical version Standard 1 General purpose

FMAB-72 Standard and medical version Standard 1 General purpose

Materials: Housing Protection class Catalogue page Ratings Panel mounting

Thermoplastic I 176 1 - 10 A / 250 VAC Screw-on version from top Wires

Thermoplastic I 179 6 - 20 A / 250 VAC Screw-on version from top Wires

Thermoplastic I 182 6 - 20 A / 250 VAC Screw-on version from top Wires

Aluminum I 185 4 - 30 A / 250 VAC Screw-on version from top Wires

Terminals for Product picture

Type Filter-Type Attenuation Filter stage Application

FMLB-41 Standard and medical version Standard 1 General purpose

FMLB-09 Standard and medical version Standard 1 General purpose

FMLB-51 Standard and medical version Standard 1 General purpose

FMW-150 Standard Version Medium 3 High symmetrical and asymmetrical attenuation Metal I 196

Materials: Housing Protection class Catalogue page

Aluminum I 188

Aluminum I 191

Aluminum I 193

174

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 1 - 10 A / 250 VAC Screw-on version from top Wires

BLOCK FILTERS
2 - 6 A / 250 VAC Screw-on version from top Wires 10 - 20 A / 250 VAC Screw-on version from top Wires 1 - 10 A / 250 VAC Screw-on version from top Wires

Terminals for Product picture

Type Filter-Type Attenuation Filter stage Application

FMW-41 Standard and medical version Standard 1 General purpose

FMW-52 Standard Version High 2 For high requirements

FMW-55 Standard Version Standard 1 General purpose

FSS Standard Version Medium 2 especially against symmetrical interference Aluminum I 205

Materials: Housing Protection class Catalogue page Ratings Panel mounting

Aluminum I 198 3 - 10 A / 250 VAC Screw-on version from top Wires

Aluminum I 201 12 - 30 A / 250 VAC Screw-on version from top Wires

Aluminum I 203 8 - 25 A / 250 VAC Screw-on version from top Wires

Terminals for Product picture

Type Filter-Type Attenuation Filter stage Application

FSW Standard Version High 2

FMAB Standard Version Excellent 1

FMBB Standard Version Excellent 2 High attenuation at high loads

Especially against asymmetrical High attenuation at high loads interference Aluminum I 207 Metal I 209

Materials: Housing Protection class Catalogue page

Metal I 211

175

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5500

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Component: PCB mounted - 1 Function: Line filter in standard and medical version - For PCB mounting

Characteristics
- Ultra-compact design - Shield available separately (German silver) - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 6 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 6 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting Thermoplastic, UL 94V-0 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Degree of protection Protection class Terminals Materials: Housing

Dimensions Line Filter

Shield

176

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5500
Technical data of filter-components
Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 8 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

BLOCK FILTERS

Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.3 2 x 11 2x4 2 x 1.6 2 x 0.7 2 x 0.5 2 x 0.3 47 47 47 47 47 47 47 47 47 47 47 2.2 2.2 2.2 2.2 2.2

R [M ]

1 1 1 1 1 1

Diagrams Standard version

Medical version

1) Line 2) Load

1) Line 2) Load - - - - differential mode _____ common mode

Attenuation loss
Standard version

1A

2A

4A

6A

Medical version

1A

2A

4A

6A

177

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

5500
Variants
Order Number 5500.0155.1 5500.0255.1 5500.0455.1 5500.0655.1 5500.1055.1 5500.0155.3 5500.0255.3 5500.0455.3 5500.0655.3 5500.0855.3 5500.1055.3 5500.0001 Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 8 10 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) without 100 Pcs

BLOCK FILTERS

EMC-Shielding Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Without EMC-shield Shield

Packaging unit

178

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-01

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: PCB mounted, from top - Line filter in standard and medical version, 1-stage, standard attenuation - For PCB-mounting or quick connect terminals - Excellent price/perfomance ratio

Characteristics
- Cost-saving plastic housing Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - For standard applications - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection - medical version M80

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 0.5 - 6,5 A @ Ta 40 C / 250 VAC; 50 Hz 0.5 - 6,5 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting , tin-plated Thermoplastic, black, UL 94V-0 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

179

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-01
Dimensions Case 13P / 18P / 24P

BLOCK FILTERS

Diagrams S1

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

0.6 A (5500.2000)

1 A (5500.2001)

2 A (5500.2002)

4 A (5500.2003)

6 A (5500.2004)

0.7 A (5500.2005)

1 A (5500.2006)

2 A (5500.2007)

3 A (5500.2008)

1 A (5500.2009)

3 A (5500.2010)

180

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-01
Medical version

BLOCK FILTERS

0.6 A (5500.2116)

1 A (5500.2117)

2 A (5500.2118)

4 A (5500.2119)

6 A (5500.2120)

0.7 A (5500.2121)

1 A (5500.2122)

2 A (5500.2123)

3 A (5500.2124)

1 A (5500.2125)

3 A (5500.2126)

Variants
Order Number 5500.2000 5500.2001 5500.2002 5500.2003 5500.2004 5500.2005 5500.2006 5500.2007 5500.2008 5500.2009 5500.2010 5500.2116 5500.2117 5500.2118 5500.2119 5500.2120 5500.2121 5500.2122 5500.2123 5500.2124 5500.2125 5500.2126 Rated current Filter-Type [A] 0.6 1 2 4 6 0.7 1 2 3 1 3 0.6 1 2 4 6 0.7 1 2 3 1 3 50 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) L [mH] 2 x 40 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 40 2 x 20 2x6 2x3 2 x 30 2x4 2 x 40 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 40 2 x 20 2x6 2x3 2 x 30 2x4 Co / C2 (X2) [F] 0.015 0.015 0.015 0.015 0.015 0.015 0.022 0.022 0.022 0.047 0.047 0.015 0.015 0.015 0.015 0.015 0.015 0.022 0.022 0.022 0.047 0.047 C1 (Y2) [nF] 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 Diagram S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 Case 13P 13P 13P 13P 13P 18P 18P 18P 18P 24P 24P 13P 13P 13P 13P 13P 18P 18P 18P 18P 24P 24P

Packaging unit

181

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-02

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: PCB mounted, from top - Line filter in standard and medical version, 1-stage, standard attenuation - For PCB mounting - Excellent price/perfomance ratio

Characteristics
- Cost-saving plastic housing Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - For standard applications - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection - medical version M80

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 0.5 - 6,5 A @ Ta 40 C / 250 VAC; 50 Hz 0.5 - 6,5 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting , tin-plated Thermoplastic, black, UL 94V-0 Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

182

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-02
Dimensions Case 27P

BLOCK FILTERS

Case 27-1P

Diagrams S3 S2

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

0.5 A (5500.2014)

1 A (5500.2015)

1.6 A (5500.2016)

2.5 A (5500.2017)

4 A (5500.2018)

6.5 A (5500.2019)

0.8 A (5500.2020)

183

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FPP-02
Medical version

BLOCK FILTERS

0.5 A (5500.2127)

1 A (5500.2130)

1.6 A (5500.2131)

2.5 A (5500.2132)

4 A (5500.2133)

6.5 A (5500.2128)

0.8 A (5500.2129)

Variants
Order Number 5500.2014 5500.2015 5500.2016 5500.2017 5500.2018 5500.2019 5500.2020 5500.2127 5500.2130 5500.2131 5500.2132 5500.2133 5500.2128 5500.2129 Rated current Filter-Type [A] 0.5 1 1.6 2.5 4 6,5 0.8 0.5 1 1.6 2.5 4 6,5 0.8 50 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) L [mH] 2 x 40 2 x 10 2x6 2x2 2x1 2x1 2 x 20 2 x 40 2 x 10 2x6 2x2 2x1 2x1 2 x 20 Co / C2 (X2) [F] 0.1 0.1 0.1 0.1 0.1 0.1 0.068/0.015 0.1 0.1 0.1 0.1 0.1 0.1 0.068/0.015 C1 (Y2) [nF] 2.2 2.2 2.2 2.2 2.2 2.2 2.2 Diagram S2 S2 S2 S2 S2 S2 S3 S2 S2 S2 S2 S2 S2 S3 Case 27P 27P 27P 27P 27P 27P 27-1P 27P 27P 27P 27P 27P 27P 27-1P

Packaging unit

184

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMAB-72

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: PCB mounted, from top - Line filter in standard and medical version, 1-stage, standard attenuation - For PCB mounting

Characteristics
- Aluminum case provides good shielding Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Universal line filter for standard applications - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- medical version M80

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 2 - 16 A @ Ta 40 C / 250 VAC; 50 Hz 2 - 16 A @ Ta 40 C / 125 VAC; 60 Hz > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 For PCB mounting , tin-plated Aluminum Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 72

185

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMAB-72
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

2A

4A

6A

10 A

16 A

Medical version

2A

4A

6A

10 A

16 A

186

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMAB-72
Variants
Order Number 5500.2021 5500.2022 5500.2023 5500.2024 5500.2025 5500.2106 5500.2107 5500.2108 5500.2109 5500.2110 Rated current Filter-Type [A] 2 4 6 10 16 2 4 6 10 16 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

BLOCK FILTERS

L [mH] 2x8 2 x 3.5 2 x 1.8 2 x 0.82 2 x 0.65 2x8 2 x 3.5 2 x 1.8 2 x 0.82 2 x 0.65

Cx (X2) [nF] 100 100 100 100 100 100 100 100 100 100

Cy (Y2) [nF] 4.7 4.7 4.7 4.7 4.7

R [M ] 1 1 1 1 1 1 1 1 1 1

Case 72 72 72 72 72 72 72 72 72 72

Packaging unit

187

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-41

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: Screw-on version, from top - Line filter in standard and medical version, 1-stage, standard attenuation - Quick connect terminals 6.3 x 0.8 mm

Characteristics
- Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- medical version M80 - Version with ZNR-varistor for overvoltage protection

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 41

188

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-41
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

4A

6A

10 A

Medical version

1A

2A

4A

6A

10 A

189

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-41
Variants
Order Number 5500.2026 5500.2027 5500.2028 5500.2029 5500.2030 5500.2077 5500.2078 5500.2079 5500.2080 5500.2081 Rated current Filter-Type [A] 1 2 4 6 10 1 2 4 6 10 25 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

BLOCK FILTERS

L [mH] 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3 2 x 10 2x4 2 x 1.5 2 x 0.8 2 x 0.3

Cx (X2) [nF] 68 68 68 68 68 68 68 68 68 68

Cy (Y2) [nF] 2.2 2.2 2.2 2.2 2.2

Case 41 41 41 41 41 41 41 41 41 41

Packaging unit

190

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-09

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: Screw-on version, from top - Line filter in standard and medical version, 1-stage, standard attenuation - Quick connect terminals 6.3 x 0.8 mm - Especially effective against assymetrical interferences in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Compact design - High attenuation at maximum resp. assymmetric load independent from the line impedance - Special design for industrial application as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection - medical version M80

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 6 - 20 A @ Ta 40 C / 250 VAC; 50 Hz 6 - 20 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 73

191

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-09
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

6A

10 A

16 A

20 A

Medical version

6A

10 A

16 A

20 A

Variants
Order Number 5500.2031 5500.2032 5500.2033 5500.2034 5500.2072 5500.2073 5500.2074 5500.2076 Rated current Filter-Type [A] 6 10 16 20 6 10 16 20 10 Pcs Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) L [mH] 2 x 1.8 2 x 0.82 2 x 0.64 2 x 0.5 2 x 1.8 2 x 0.82 2 x 0.64 2 x 0.5 Cx (X2) [F] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Cy (Y2) [nF] 4.7 4.7 4.7 4.7 Case 73 73 73 73 73 73 73 73

Packaging unit

192

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-51

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: Screw-on version, from top - Line filter in standard and medical version, 1-stage, standard attenuation - Quick connect terminals 6.3 x 0.8 mm - Especially effective against symmetrical interferences in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for universal industrial applications - High attenuation at maximum resp. assymmetric load independent from the line impedance Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Special design for industrial application as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 6 - 20 A @ Ta 40 C / 250 VAC; 50 Hz 6 - 20 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.35 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

193

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-51
Dimensions Case 49

BLOCK FILTERS

Diagrams

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

6A

10 A

16 A

20 A

Medical version

6A

10 A

16 A

20 A

194

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMLB-51
Variants
Order Number 5500.2035 5500.2036 5500.2037 5500.2038 5500.2082 5500.2083 5500.2084 5500.2085 Rated current Filter-Type [A] 6 10 16 20 6 10 16 20 10 Pcs Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

BLOCK FILTERS

L [mH] 2 x 14 2x5 2x2 2 x 1.5 2 x 14 2x5 2x2 2 x 1.5

Cx (X2) [F] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

Cy (Y2) [nF] 3.3 3.3 3.3 3.3

Case 49 49 49 49 49 49 49 49

Packaging unit

195

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-150

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 3-stage, middle attenuation, broadband - Screw terminals - Very high symmetrical and asymmetrical attenuation loss in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for highest demands - High attenuation at maximum resp. assymmetric load independent from the line impedance - For standard and industrial applications - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 4 - 30 A @ Ta 40 C / 250 VAC; 50 Hz 4 - 30 A @ Ta 40 C / 125 VAC; 60 Hz IT and industrial < 1.5 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Screw terminals Metal Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 43

Case 22

196

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-150
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

4A

10 A

30 A

Variants
Order Number 5500.2048 5500.2049 5500.2050 Rated current Filter-Type [A] 4 10 30 1 Pcs Standard Version Standard Version Standard Version L1 [mH] L2 [H] 2 x 20 2x5 2x4 2 x 30 2 x 30 2 x17 L3 [H] Cx [nF] Cy1 [nF] Cy2 [nF] R [M ] 3 3 3 220 220 220 33 15 15 2.2 0.5 0.5 0.5 Case 43 43 22

Packaging unit

197

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-41

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Standard- or Medical-Filter

Description
- Chassis: Screw-on version, from top - Line filter in standard and medical version, 1-stage, standard attenuation - Quick connect terminals 6.3 x 0.8 mm

Characteristics
- Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Universal line filter for standard applications - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection - medical version M80 - Version with ZNR-varistor for overvoltage protection

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

198

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-41
Dimensions Case 41

BLOCK FILTERS

Diagrams

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

3A

6A

10 A

Medical version

1A

3A

6A

10 A

199

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-41
Variants
Order Number 5500.2039 5500.2040 5500.2041 5500.2042 5500.2098 5500.2104 5500.2100 5500.2102 Rated current Filter-Type [A] 1 3 6 10 1 3 6 10 25 Pcs Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5)

BLOCK FILTERS

L [mH] 2 x 10 2x2 2 x 0.8 2 x 0.4 2 x 10 2x2 2 x 0.8 2 x 0.4

Cx (X2) [nF] 15 15 15 15 15 15 15 15

Cy (Y2) [nF] 2.2 2.2 2.2 2.2

Case 41 41 41 41 41 41 41 41

Packaging unit

200

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-52

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 2-stage, high attenuation - Quick connect terminals 6.3 x 0.8 mm - Very high symmetrical and asymmetrical attenuation loss in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for increased requirements - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated 2-stage line filter with increased attenuation - For standard and industrial applications - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 2 - 6 A @ Ta 40 C / 250 VAC; 50 Hz 2 - 6 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 09

201

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-52
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

2A

6A

Variants
Order Number 5500.2043 5500.2044 Rated current Filter-Type [A] 2 6 10 Pcs Standard Version Standard Version L [mH] 2x3 2 x 0.8 Cx (X2) [nF] 100 100 Cy (Y2) [nF] 4.7 2.2 R [M ] 0.5 0.5 Case 09 09

Packaging unit

202

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-55

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 1-stage, standard attenuation - Quick connect terminals 6.3 x 0.8 mm - Excellent price/perfomance ratio

Characteristics
- Designed for high current applications Compact design - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - For standard and industrial applications - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 10 - 20 A @ Ta 40 C / 250 VAC; 50 Hz 10 - 20 A @ Ta 40 C / 125 VAC; 60 Hz IT and industrial < 2.1 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 10

203

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMW-55
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

10 A (5500.2045)

10 A (5500.2046)

20 A (5500.2047)

Variants
Order Number 5500.2045 5500.2046 5500.2047 Rated current Filter-Type [A] 10 10 20 10 Pcs Standard Version Standard Version Standard Version L [mH] 2x1 2x1 2 x 0.15 Cx (X2) [nF] 68 68 68 Cy (Y2) [nF] 2.2 22 22 Case 10 10 10

Packaging unit

204

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FSS

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 2-stage, middle attenuation, broadband - Quick connect terminals 6.3 x 0.8 mm - Especially effective against symmetrical interferences in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for increased requirements - 2-stage line filter with increased attenuation Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Especially suitable for use in switching power supplies e.g. in electronic designs with high repetitive switching frequency - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz IT and industrial < 0.25 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 10

Case 19

Case 27

205

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FSS

BLOCK FILTERS

Case 48

Diagrams Standard Version

1) Line 2) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

1A

2A

3A

4A

6A

10 A

Variants
Order Number 5500.2051 5500.2052 5500.2053 5500.2054 5500.2055 5500.2056 5500.2057 Rated current Filter-Type [A] 1 2 3 4 6 10 16 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version L1 [mH] L2 [mH] L3 [mH] Cx1 [F] Cx2 [F] Cy1 [nF] Cy2 [nF] R [M ] 2 x 15 2 x 10 2 x 12 2 x 10 2x6 2x5 2x4 1 0.4 1 0.8 0.5 0.2 0.2 0.2 0.2 0.4 0.1 0.1 0.1 0.1 0.1 0.1 0.47 0.47 0.47 0.68 0.68 0.68 1 2.2 1.5 1.5 1.5 10 10 10 10 1 1 1 4.7 4.7 4.7 4.7 1 1 1 1 1 1 1 Case 10 10 48 48 48 19 27

Packaging unit

206

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FSW

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 2-stage, high attenuation - Quick connect terminals 6.3 x 0.8 mm - Especially effective against assymetrical interferences in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for increased requirements - 2-stage line filter with increased attenuation Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Especially suitable for use in switching power supplies e.g. in electronic designs with high repetitive switching frequency - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 3 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 3 - 10 A @ Ta 40 C / 125 VAC; 60 Hz IT and industrial < 0.25 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Aluminum Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 49

207

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FSW
Diagrams Standard Version

BLOCK FILTERS

1) Line 2) Load

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

3 A (5500.2058)

3 A (5500.2059)

6 A (5500.2060)

6 A (5500.2061)

10 A (5500.2062)

10 A (5500.2063)

Variants
Order Number 5500.2058 5500.2059 5500.2060 5500.2061 5500.2062 5500.2063 Rated current Filter-Type [A] 3 3 6 6 10 10 10 Pcs Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version L [mH] 2x2 2x2 2 x 0.8 2 x 0.8 2 x 0.4 2 x 0.4 Cx [F] Cy1 [nF] Cy2 [nF] R [M ] 0.1 0.1 0.1 0.1 0.1 0.1 1.5 22 1.5 22 1.5 22 1 1 1 1 1 1 1 1 1 1 1 1 Case 49 49 49 49 49 49

Packaging unit

208

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMAB

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 1-stage, high attenuation - Screw terminals - Very high symmetrical and asymmetrical attenuation loss in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for high current applications - High attenuation at maximum resp. assymmetric load independent from the line impedance - Special design for industrial application as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 12 - 30 A @ Ta 40 C / 250 VAC; 50 Hz 12 - 30 A @ Ta 40 C / 125 VAC; 60 Hz other < 5.2 mA (250 V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Screw terminals Metal Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 24-2

Case 24-6

209

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMAB
Diagrams

BLOCK FILTERS

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

12 A

20 A

30 A

Variants
Order Number 5500.2064 5500.2065 5500.2066 Rated current Filter-Type [A] 12 20 30 2 Pcs Standard Version Standard Version Standard Version L [mH] 2 x 10 2 x 3.5 2 x 1.5 C1 (X2) C2 (Y2) C3 (Y2) C4 (X2) R [M ] [F] [nF] [nF] [F] 2.2 2.2 2.2 10 10 15 47 47 47 1 1 1 1 1 1 Case 24-2 24-2 24-6 Screw clamp [mm2] 4 4 6

Packaging unit

210

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMBB

BLOCK FILTERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Description
- Chassis: Screw-on version, from top - Line-filter in standard version, 2-stage, very high attenuation - Screw terminals - Very high symmetrical and asymmetrical attenuation loss in the frequency range (from 10kHz up to 30MHz)

Characteristics
- Designed for high current applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Special design for industrial application as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- Version with wire connection

Technical data
Ratings IEC Ratings UL/CSA Leakage current Dielectric strength 8 - 25 A @ Ta 40 C / 250 VAC; 50 Hz 8 - 25 A @ Ta 40 C / 125 VAC; 60 Hz IT and industrial < 3.5 mA ( V / 60 Hz) > 2.7 kVDC between L-N > 1.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 100 C 25/100/21, IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Screw terminals Metal Line filter Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details see page 288

Allowable operation temp. Climatic category Protection class Terminals Materials: Housing

Dimensions Case 24-2

Case 16-2

211

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

FMBB

BLOCK FILTERS

Case 31-2

Case 31-6

Diagrams S2 S1

Attenuation loss
Standard version

- - - - differential mode

_____ common mode

8A

12 A

16 A

25 A

Variants
Order Number 5500.2068 5500.2069 5500.2070 5500.2071 Rated current Filter-Type [A] 8 12 16 25 Standard Version Standard Version Standard Version Standard Version L [mH] 2x7 2x5 2 x 3.5 2 x 3.5 C1 (X2) C2 (X2) C3 (X2) C4 (Y2) C5 (Y2) [F] [F] [F] [nF] [nF] 0.1 2.2 2.2 2.2 0.15 2.2 2.2 2.2 0.47 2.2 2.2 2.2 2.2 33 33 33 2.2 2.2 2.2 R1, R2 Diagram [M ] 1 1 1 1 S1 S2 S2 S2 Case 16-2 24-2 31-2 31-6 Screw clamp [mm2] 4 4 4 6

Packaging unit

5 Pcs

212

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

APPLIANCE COUPLERS

APPLIANCE COUPLERS

213

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART

APPLIANCE COUPLERS

Ratings Panel mounting

2.5 A / 250 VAC Screw-on; Snap-in front-/rear-side; front-side Panel mount; PCB; Wires

2.5 A / 250 VAC Screw-on front-side PCB or wires

10 A / 250 VAC Screw-on front-side Wires

10 A / 250 VAC Screw-on; Snap-in front-/rear-side; front-side Wires

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

0720-FP; 0721-PP; 0720-FS;

0724

8843.FL; 8843.FLR

6100-3; 6100-4

Line filter Protection class Catalogue page Ratings Panel mounting II 217 10 A / 250 VAC Screw-on; Snap-in front-/rear-side; front-side Wires I 219 10 A / 250 VAC Screw-on; Snap-in front-/rear-side; front-side Wires I 221 10 A / 250 VAC Screw-on; Snap-in front-/rear-side; front-side Wires I 222 10 A / 250 VAC Screw-on rear-side PCB

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

6102-3; 6102-5

6110-3; 6110-4

6120-3; 6120-5

GSP1

similar photo, protection class II

for increased temperature requirements

Line filter Protection class Catalogue page II 224 I 226 I 228 I or II 230

214

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 10 A / 250 VAC Sandwich or rear-side

APPLIANCE COUPLERS
10 A / 250 VAC Screw-on from top PCB 10 A / 250 VAC Snap-in front-side PCB 16 A / 250 VAC Screw-on; Snap-in front-side Wires

Terminals for Product picture

PCB

Type Line switch Fuseholder Voltage selector Comment

GSP2

8843.ZP30

6130-56

4798; 4793

Line filter Protection class Catalogue page Ratings Panel mounting I or II 232 10 A / 250 VAC Screw-on; Snap-in front-side Wires I 235 10 A / 250 VAC Screw-on; Snap-in front-side Wires I 236 10 A / 250 VAC Screw-on; Snap-in front-side Wires I 238 10 A / 250 VAC Screw-on rear-side PCB

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

6600-3; 6600-4

4721; 4723

4787; 4788

P675/PC

Outlets shuttered

Backplane outlets

Line filter Protection class Catalogue page I 240 I 242 I 244 I 246

215

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART
Ratings Panel mounting 16 A / 250 VAC Screw-on front-side Wires

APPLIANCE COUPLERS
10 A / 250 VAC 10 A / 250 VAC 10 A / 250 VAC

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

0723

4782; 4785

4781; 4784

4732; 4735; 4733; 4736

for increased temperature requi- For max. wire size 3x1 mm; For rements max. wire size 3x2 mm

Line filter Protection class Catalogue page Ratings Panel mounting I 248 10 A / 250 VAC I 249 10 A / 250 VAC I 250 16 A / 250 VAC I 251 16 A / 250 VAC

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

P685

4300-06

4795; 4790

4796; 4789

4 positions

Line filter Protection class Catalogue page I 253 I 254 I 255 I 256

216

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0720-FS/FP, 0721-PS/PP

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

0720-FS

0721-PS

0720-FP

C8

70 C

Description
- Panel mount: Screw-on version [0720-FP; 0720-FS]; Snap-in version [0721-PP; 0721-PS]; from front or rear-side [0720-FP; 0720-FS]; from front side [0721-PP; 0721-PS] Connector, - [0720-FS] Pin temperature 70 C, Protection class II - PCB [0720-FP; 0721-PP]; Solder terminals [0720-FS; 0721-PS]

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength Allowable operation temp. Degree of protection Protection class 2.5 A / 250 VAC; 50 Hz 2.5 A / 250 VAC; 60 Hz > 2 kVAC between L-N (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class II acc. to IEC 61140 Terminals [0720-FP; 0721-PP] PCB solder terminals Terminals [0720-FS; 0721-PS] Solder terminals Panel thickness s [0720-FP] Screw-on: from 4 mm max 4 mm Mounting screw torque max 0.5 Nm Panel thickness s [0721-PP; Snap-in from 0.8-1.2 mm 0721-PS] Panel thickness s [0720-FS] Screw-on: max 4 mm Mounting screw torque max 0.5 Nm Materials: Housing Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet C8 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 2.5 A, Protection class II

Dimensions 0720-FS

0720-FP

Solder terminals for wires

Solder terminals for PCB

217

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0720-FS/FP, 0721-PS/PP
Drilling diagrams PCB Layout

APPLIANCE COUPLERS

PCB Layout

Variants
Order Number 4300.0097 4300.0099 4300.0096 4300.0098 Type 0720-FP 0721-PP 0720-FS 0721-PS 50 Pcs Panel mounting Screw-on Snap-in Screw-on Snap-in 0.8-1.2 4 0.8-1.2 Panel thickness s Terminals [mm] PCB solder terminals PCB solder terminals Solder terminals Solder terminals

Packaging unit

218

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0724

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Solder terminals for wires

Terminals for PCB

C6

70 C

Description
- Panel mount: Screw-on version from front or rear-side - Connector, Pin temperature 70 C, Protection class I - Solder terminals for wires or PCB

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 2.5 A / 250 VAC; 50 Hz 2.5 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Solder terminals for wires or PCB Screw-on: max 4 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 C6 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 2.5 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions Solder terminals for PCB

Solder terminals for wires

219

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0724
Drilling diagrams PCB Layout

APPLIANCE COUPLERS

Variants
Order Number 4300.0101 4300.0100 Type 0724 0724 50 Pcs Panel mounting Screw-on Screw-on Panel thickness s Terminals [mm] 4 4 PCB Solder terminals

Packaging unit

220

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

8843-FL, 8843-FLR

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

8843-FL

8843-FLR

C14

70 C

Description
- Panel mount: Screw-on version from front side - Connector, Pin temperature 70 C, Protection class I - Screw terminals

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Screw terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoset, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions 8843-FL

8843-FLR

Screw M3

Screw M3

Variants
Order Number 4300.0065 4300.0066 Type 8843-FL 8843-FLR 50 Pcs

Packaging unit

Accessories

see page

277

221

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6100-3, 6100-4

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

6100-3

6100-4

C14

70 C

Description
- Panel mount: Screw-on version [6100-3]; Snap-in version [6100-4] from front or rear-side [6100-3]; from front side [6100-4] - Connector, Pin temperature 70 C, Protection class I - Solder terminals or quick connect terminals - Alternative: protection class II version

Other versions on request:


- Types for rivet mounting available upon request - other panel thickness

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [6100-3] Panel thickness s [6100-4] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection [6100-3] Degree of protection [6100-4] Protection class

Dimensions 6100-3 (6102-3)

6100-4 (6102-5)

E: Solder terminals<TAB/><TAB/>20.5 mm E: Quick connect terminals<TAB/>23.5 mm

E: Solder terminals<TAB/><TAB/>22.5mm E: Quick connect terminals<TAB/>25.5 mm S: 1.0; 1.2; 1.5; 2.0; 2.5; 3.0 mm

222

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6100-3, 6100-4
Variants
Order Number 6100.3200 6100.3300 6100.3100 6100.4210 6100.4212 6100.4215 6100.4220 6100.4225 6100.4230 6100.4216 6100.4310 6100.4312 6100.4315 6100.4320 6100.4325 6100.4330 6100.4110 6100.4112 6100.4115 6100.4120 6100.4125 6100.4130 Type 6100-3 6100-3 6100-3 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 6100-4 50 Pcs Protection class I I I I I I I I I I I I I I I I I I I I I I

APPLIANCE COUPLERS

Panel mounting Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in

Panel thickness s Terminals [mm] Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.5 x 0.8 mm 1 1.2 1.5 2 2.5 3 1.6 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm see page 277

Packaging unit

Accessories

223

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6102-3, 6102-5

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

6102-3

6102-5

C18

70 C

Description
- Panel mount: Screw-on version [6102-3]; Snap-in version [6102-5] from front or rear-side [6102-3]; from front side [6102-5] - Connector, Pin temperature 70 C, Protection class II - Solder terminals or quick connect terminals - Alternative: Version in protection class I

Other versions on request:


- Types for rivet mounting available upon request - other panel thickness

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength Allowable operation temp. Degree of protection [6102-3] Degree of protection [6102-5] Protection class 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class II acc. to IEC 61140 Terminals Panel thickness s [6102-3] Panel thickness s [6102-5] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class II

Dimensions 6100-3 (6102-3)

6100-4 (6102-5)

E: Solder terminals<TAB/><TAB/>20.5 mm E: Quick connect terminals<TAB/>23.5 mm

E: Solder terminals<TAB/><TAB/>22.5mm E: Quick connect terminals<TAB/>25.5 mm S: 1.0; 1.2; 1.5; 2.0; 2.5; 3.0 mm

224

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6102-3, 6102-5
Variants
Order Number 6102.3200 6102.3300 6102.3100 6102.5215 6102.5220 6102.5225 6102.5230 6102.5310 6102.5312 6102.5315 6102.5320 6102.5325 6102.5330 6102.5110 6102.5112 6102.5115 6102.5125 6102.5130 Type 6102-3 6102-3 6102-3 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 6102-5 50 Pcs Protection class II II II II II II II II II II II II II II II II II II

APPLIANCE COUPLERS

Panel mounting Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in

Panel thickness s Terminals [mm] Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2.5 3 Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm see page 277

Packaging unit

Accessories

225

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6110-3, 6110-4

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

6110-3

6110-4

C16

120 C

Description
- Panel mount: Screw-on version [6110-3]; Snap-in version [6110-4] from front or rear-side [6110-3]; from front side [6110-4] - Connector, Pin temperature 120 C, Protection class I - Solder terminals or quick connect terminals

Other versions on request:


- Types for rivet mounting available upon request - other panel thickness

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 120 C from front side IP40 acc. to IEC 60529 from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [6110-3] Panel thickness s [6110-4] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C16 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for warm condition) pin-temperature 120 C, 10 A, Protection class I

Allowable operation temp. Degree of protection [6110-3] Degree of protection [6110-4] Protection class

Dimensions 6110-3

6110-4

E: Solder terminals<TAB/><TAB/>20.5 mm E: Quick connect terminals<TAB/>23.5 mm

E: Solder terminals<TAB/><TAB/>22.5 mm E:Quick connect terminals<TAB/>25.5 mm S: 1.0; 1.2; 1.5; 2.0; 2.5; 3.0 mm

226

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6110-3, 6110-4
Variants
Order Number 6110.3300 6110.3100 6110.3200 6110.4210 6110.4212 6110.4215 6110.4220 6110.4225 6110.4310 6110.4312 6110.4315 6110.4320 6110.4325 6110.4330 6110.4110 6110.4112 6110.4115 6110.4120 6110.4125 6110.4130 Type 6110-3 6110-3 6110-3 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 6110-4 Panel mounting Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in

APPLIANCE COUPLERS

Panel thickness s Terminals [mm] Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick-connect terminals 4.8 x 0.8 mm 1 1.2 1.5 2 2.5 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm

Additional types on request.

Packaging unit

50 Pcs

Accessories

see page

278

227

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6120-3, 6120-5

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

6120-3

6120-5

C16 A

155 C

Description
- Panel mount: Screw-on version [6120-3]; Snap-in version [6120-5] from front or rear-side [6120-3]; from front side [6120-5] - Connector, Pin temperature 155 C, Protection class I - Solder terminals or quick connect terminals

Other versions on request:


- Quick-connect terminals 4.8 x 0.8 mm - other panel thickness - Quick-connect terminals 4.8 x 0.8 mm

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 155 C from front side IP40 acc. to IEC 60529 from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [6120-3] Panel thickness s [6120-5] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2.5/3 mm Thermoplastic, black, UL 94V-0 C16A acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for hot condition) pin-temperature 155 C, 10 A, Protection class I

Allowable operation temp. Degree of protection [6120-3] Degree of protection [6120-5] Protection class

Dimensions 6120-3

6120-5

E: Solder terminals:<TAB/><TAB/>22.5 mm E: Quick connect terminals:<TAB/>25.5 mm

E: Solder terminals<TAB/><TAB/>22.5 mm E: Quick connect terminals<TAB/>25.5 mm S: 1.5; 2.5; 3.0 mm

228

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6120-3, 6120-5
Variants
Order Number 6120.3300 6120.3100 6120.5315 6120.5325 6120.5330 6120.5115 6120.5125 6120.5130 Type 6120-3 6120-3 6120-5 6120-5 6120-5 6120-5 6120-5 6120-5 Panel mounting Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in

APPLIANCE COUPLERS

Panel thickness s Terminals [mm] Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm 1.5 2.5 3 1.5 2.5 3 Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm

Quick-connect terminals 4,8 x 0,8 mm on request.

Packaging unit

50 Pcs

229

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSP1

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

C14

C18

70 C

70 C

Description
- Panel mount, Screw-on version from rear-side - Connector, Pin temperature 70 C, protection class I or II - For PCB mounting

Other versions on request:


- Ground terminal with quick-connect terminal 6,3 x 0,8 mm

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 3 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Terminals For PCB mounting ; Ground terminal: Quick connect terminals 4.8 x 0.8 mm angled or straight Screw-on: max 3 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 C14 or C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I or II

Panel thickness s Materials: Housing Appliance-inlet /-outlet

Allowable operation temp. Degree of protection Protection class

Dimensions

without insulation cover

with insulation cover

Ground terminal

Ground terminal

straight

angled

230

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSP1
Drilling diagrams PCB Layout Ground terminal angled

APPLIANCE COUPLERS

PCB Layout Ground terminal straight

X deleted for protection class II

X deleted for protection class II

Variants
Order Number GSP1.9103.1 GSP1.9113.1 GSP1.9101.1 GSP1.9503.1 GSP1.9203.1 GSP1.8111.1 GSP1.8401.1 GSP1.8501.1 GSP1.8201.1 GSP1.9100.1 GSP1.9110.1 GSP1.9500.1 GSP1.9200.1 GSP1.8100.1 GSP1.8110.1 GSP1.8500.1 GSP1.8200.1 Protection class PCB terminal spa - Mounting flange with cing I I I I I I I I I II II II II II II II II 50 Pcs 7/7.3 7/7.3 7/7.3 7/7.3 7/7.3 9.05/9.7 9.05/9.7 9.05/9.7 9.05/9.7 7/7.3 7/7.3 7/7.3 7/7.3 9.05/9.7 9.05/9.7 9.05/9.7 9.05/9.7 holes for screws M3 holes for screws M3 holes for screws M3 holes for self-tapping screws 3mm, 4 screws enclosed pre-inserted nuts M3, 4 pcs. holes for screws M3 holes for screws M3 holes for self-tapping screws 3mm, 4 screws enclosed pre-inserted nuts M3, 4 pcs. holes for screws M3 holes for screws M3 holes for self-tapping screws 3mm, 4 screws enclosed pre-inserted nuts M3, 4 pcs. holes for screws M3 holes for screws M3 holes for self-tapping screws 3mm, 4 screws enclosed pre-inserted nuts M3, 4 pcs. Ground terminal 4.8 x 0.8 mm angled to pin axis angled to pin axis straight angled to pin axis angled to pin axis straight straight straight straight angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight Cover

Packaging unit

231

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSP2

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

Snap-in mounting

Screw-on mounting

C14

C18

70 C

70 C

Description
- Panel mount: Snap-in or screw-on mounting on PCB, sandwich or rear-side - Connector, Pin temperature 70 C, protection class I or II - For PCB mounting

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 3 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Terminals For PCB mounting ; Ground terminal: Quick-connect terminals 4.8 x 0.8 mm angled to pin axis Solder terminal on request Sandwich or rear-side: 1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C14 or C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I or II

Allowable operation temp. Degree of protection Protection class

Panel thickness s Materials: Housing Appliance-inlet /-outlet

Dimensions

232

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSP2

APPLIANCE COUPLERS

Screw-on mounting

with insulation cover

Rear panel mounting

Split panel mounting (Sandwich)

Drilling diagrams Drilling plan

d1 = 6 0.05 for Snap-in mounting d1 = 3.6 0.05 for screw-on mounting with self-tapping screws 3 mm (EJOT-PT), 2 screws enclosed

233

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GSP2
Variants
Order Number GSP2.9203.11 GSP2.9203.12 GSP2.9203.13 GSP2.9203.14 GSP2.9203.15 GSP2.9203.16 GSP2.9213.15 GSP2.9213.13 GSP2.9213.14 GSP2.9213.16 GSP2.9103.11 GSP2.9103.13 GSP2.9103.14 GSP2.9103.15 GSP2.9103.16 GSP2.9113.13 GSP2.9113.14 GSP2.9113.15 GSP2.9113.16 GSP2.9200.13 GSP2.9200.15 GSP2.9210.13 GSP2.9210.14 GSP2.9210.15 GSP2.9210.16 GSP2.9100.13 GSP2.9100.16 GSP2.9110.14 GSP2.9110.15 Protection class Panel mounting I I I I I I I I I I I I I I I I I I I II II II II II II II II II II Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Screw-on Screw-on Screw-on Screw-on

APPLIANCE COUPLERS

Panel thickness s Ground terminal 4.8 x 0.8 mm [mm] 1 1.2 1.5 2 2.5 3 1.5 2 3 1 1.5 2 2.5 3 1.5 2 2.5 3 1.5 2.5 1.5 2 2.5 3 1.5 3 2 2.5 angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis angled to pin axis straight straight straight straight straight straight straight straight straight straight

Cover

Additional version on request, e.g.: Ground terminal straigt or quick-connect terminal 6,3 x 0,8 mm

Packaging unit

50 Pcs

234

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

8843.ZP30

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Description
- Panel mount: Screw-on mounting on PCB from front side - Connector, Pin temperature 70 C, Protection class I - For PCB mounting

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s For PCB mounting Screw-on mounting on PCB: max 1.6 mm Mounting screw torque Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Materials: Housing Appliance-inlet /-outlet

Dimensions

Variants
Order Number 4300.0076 Panel mounting Screw-on mounting on PCB 50 Pcs Panel thickness s [mm] 1.6

Packaging unit

235

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6130-56

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

C14

70 C

Description
- Panel mount: Snap-in version from front side - Connector, Pin temperature 70 C, Protection class I - For PCB mounting

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet For PCB mounting ; Solder terminals Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions

236

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6130-56
Drilling diagrams

APPLIANCE COUPLERS

S: 1.0; 1.2; 1.5; 2.0; 2.5; 3.0 mm

Variants
Order Number 6130.5610 6130.5612 6130.5615 6130.5620 6130.5625 6130.5630 Panel mounting Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in 50 Pcs Panel thickness s [mm] 1 1.2 1.5 2 2.5 3

Packaging unit

237

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4798, 4793

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4798

4793

C20

70 C

Description
- Panel mount: Screw-on version [4798]; Snap-in [4793]; from front side - Connector, Pin temperature 70 C, Protection class I - Solder terminals or quick connect terminals

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength [4798] 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2.2 kVAC between L-N > 4 kVAC between L/N-PE (1 min/50 Hz) > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [4798] Panel thickness s [4793] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I

Dielectric strength [4793]

Allowable operation temp. Degree of protection [4798] Degree of protection [4793] Protection class

Dimensions 4798

4793

36.00

21.00 3.00 R 3.0 max 32.20 32.00

28.00

24.20 24.00

S 31.3

A = 31.5 mm: quick-connect terminals 6.3 x 0.8 mm A = 30 mm: quick-connect terminals 4.8 x 0.8 mm A = 28.5 mm: solder terminals

238

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4798, 4793
Variants
Order Number 4798.9000 4798.9200 4793.3000 4793.8000 4793.4000 4793.5000 4793.6000 4793.7000 4793.3200 4793.8200 4793.4200 4793.5200 4793.6200 4793.7200 Panel mounting Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in 100 Pcs 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3

APPLIANCE COUPLERS

Panel thickness s Terminals [mm] Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm

Packaging unit

Accessories

see page

278

239

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6600-3, 6600-4

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

6600-3

6600-4

70 C

Description
- Panel mount: Screw-on version [6600-3]; Snap-in version [6600-4] - Outlet, Pin temperature 70 C, Protection class I - Solder terminals or quick connect terminals from front side

Other versions on request:


- Types for rivet mounting available upon request - other panel thickness

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [6600-3] Panel thickness s [6600-4] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions 6600-3

6600-4

E = solder terminals 3.5x0.8mm<TAB/><TAB/>24.1 mm E = quick connect terminals 4.8x0.8mm<TAB/>26.5 mm E = quick connect terminals 6.3x0.8mm<TAB/>27.5 mm

E: solder terminals 3.5x0.8mm<TAB/><TAB/>24.1mm E: quick connect terminals 4.8x0.8mm<TAB/>26.5mm E: quick connect terminals 6.3x0.8mm<TAB/>27.5mm S: 1.0; 1.2; 2.0; 2.5; 3.0 mm

240

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

6600-3, 6600-4
Variants
Order Number 6600.3200 6600.3300 6600.3100 6600.4210 6600.4212 6600.4215 6600.4220 6600.4225 6600.4230 6600.4310 6600.4312 6600.4315 6600.4320 6600.4325 6600.4330 6600.4110 6600.4112 6600.4115 6600.4120 6600.4125 6600.4130 Panel mounting Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3

APPLIANCE COUPLERS

Panel thickness s Terminals [mm] Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm

1) Minimum order quantity for rivet mount types required Cord retaining clamp and insulation cover see accessoires

Packaging unit

50 Pcs

Accessories

see page

277

241

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4721, 4723

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4721

4723

70 C

Description
- Panel mount Screw-on version [4721]; Snap-in version [4723]; from front side - Outlet shuttered, Protection class I [4721]; Pin temperature 70 C [4723], Pin temperature 70 C [4721]; Protection class I [4723] - Solder terminals or quick connect terminals

Other versions on request:


- for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s [4721] Panel thickness s [4723] Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions 4721

4723

49,0 40,0 R6,0 2,50 3,50 30,0 'A' 6,3 x 90 3,5 40,0
'A'

32,5 min
35,0 2,50 S 32,5 min R 4,0 max

24,8
28,0
0,20 24,8 +0

R 4,0 max
E

E: Solder terminals 3.5 x 0.8 mm<TAB/><TAB/>28.4 mm E: Quick connect terminals 4.8 x 0.8 mm<TAB/>31.1 mm E: Quick connect terminalse 6.3 x 0.8 mm<TAB/>33.2 mm

E: Solder terminals 3.5 x 0.8 mm<TAB/><TAB/>28.4 mm E: SQuick connect terminals 4.8 x 0.8 mm<TAB/>31.1 mm E: Quick connect terminals 6.3 x 0.8 mm<TAB/>33.2 mm S: 1.0/1.2/1.5/2.0/2.5/3.0 mm

242

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4721, 4723

APPLIANCE COUPLERS

Shutter operation: shutters opened by plug insertion

Shutter operation: shutters closed when plug is removed

Variants
Order Number 4721.0100 4721.0000 4721.0300 4723.0100 4728.0100 4724.0100 4725.0100 4726.0100 4727.0100 4723.0000 4728.0000 4724.0000 4725.0000 4726.0000 4727.0000 4723.0300 4728.0300 4724.0300 4725.0300 4726.0300 4727.0300 Type 4721 4721 4721 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 4723 Panel mounting Screw-on Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 Panel thickness s Terminals [mm] Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm Solder terminals 3.8 x 0.8 mm

Class II product also available on request Cord retaining clamps and insulation covers see accessories

Packaging unit

100 Pcs

Accessories

see page

277

243

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4787, 4788

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4787

4788

70 C

Description
- Panel mount Screw-on version [4787]; Snap-in version [4788] front side - Outlet, Pin temperature 70 C, Protection class I - Solder terminals or quick connect terminals from

Other versions on request:


- Quick-connect terminals 4.8 x 0.8 mm - for protection class II - for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals [4787] Solder terminals or quick connect terminals Quick connect terminals fulfil not VDE requirements Solder terminals or quick connect terminals Screw-on: to 3 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.2/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Terminals [4788] Panel thickness s [4787] Panel thickness s [4788] Materials: Housing Appliance-inlet /-outlet

Allowable operation temp. Degree of protection Protection class

Dimensions 4787

4788

Quick connect terminals 6.3 x 0.8 mm:<TAB/>x = 11.2 mm Quick connect terminals 4.8 mm:<TAB/><TAB/>x = 9.8mm

Quick connect terminals 6.3 x 0.8 mm:<TAB/>x = 11.2 mm Quick connect terminals 4.8 mm:<TAB/>x = 9.8 mm S = 1.0; 1.2; 1.5; 2.0; 3.0 mm

244

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4787, 4788
Variants
Order Number 4787.2000 4787.1000 4788.3100 4788.8100 4788.4100 4788.5100 4788.6100 4788.7100 4788.3000 4788.8000 4788.4000 4788.5000 4788.6000 4788.7000 Type 4787 4787 4788 4788 4788 4788 4788 4788 4788 4788 4788 4788 4788 4788 Panel mounting Screw-on Screw-on Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in Snap-in

APPLIANCE COUPLERS

Panel thickness s Terminals [mm] Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm

Please consider the min. required spacing between life parts and possible conductive panel Class II products also available on request [4788]

Packaging unit

100 Pcs

245

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

P675/PC

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

70 C

Description
- Panel mount: Screw-on version from rear-side - Outlet, Pin temperature 70 C, Protection class I - For PCB mounting

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals For PCB mounting ; Ground terminal: Quick connect terminals 4.8 x 0.8 mm straight Screw-on: max 3 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Panel thickness s Materials: Housing Appliance-inlet /-outlet

Allowable operation temp. Degree of protection Protection class

Dimensions

Drilling diagrams

246

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

P675/PC
Variants
Order Number 4300.0251 Panel mounting Screw-on 30 Pcs

APPLIANCE COUPLERS

Panel thickness s [mm] 3

Packaging unit

247

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0723

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

VDE

70 C

Description
- Panel mount: Screw-on version from front side - Outlet, Pin temperature 70 C, Protection class I - Solder terminals or quick connect terminals We recommend for new applications type

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 J acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions

Variants
Order Number 6653.3300 6653.3100 Terminals Quick connect terminals 6.3 x 0.8 mm Quick-connect terminals 4.8 x 0.8 mm 50 Pcs

Packaging unit

Accessories

see page

278

248

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4782, 4785

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4782

4785

C13

70 C

Description
- Rewireable connector: Screw-on version - Outlet, Pin temperature 70 C, Protection class I - Cable - Substitute for type ;

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 C13 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions 4782
61,5 21,0

4785

28,7

87,0

Variants
Order Number 4782.0000 4782.0100 4785.0000 4785.0100 Color black black black black Max. cable diameter 8.5 mm 10.0 mm 8.5 mm 10.0 mm Max. wire size 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

100 Pcs

Accessories

see page

278

249

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4781, 4784

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4781

4784

C15

120 C

Description
- Rewireable connector: Screw-on [4781]; Screw-on version [4784] - Outlet, Pin temperature 120 C, Protection class I - Cable - Substitute for type ;

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 120 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 C15 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for warm condition) pin-temperature 120 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions 4781

4784
51,0 33,0 21,0

28,7 44,5 70,0

Variants
Order Number 4781.0000 4781.0100 4784.0000 4784.0100 Color black black black black Max. cable diameter 8.5 mm 10.0 mm 8.5 mm 10.0 mm Max. wire size 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

100 Pcs

Accessories

see page

278

250

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4732/33, 4735/36

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4732/4735

4733/4736

70 C

Description
- Rewireable connector: [4735] Screw-on version Connector, Pin temperature 70 C Protection class I Cable Substitute for type ;

Technical data
Ratings IEC Ratings UL/CSA [4732; 4733] Ratings UL/CSA [4735; 4736] Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 E acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions 4732

4733
47,0 20,8 81,0 20,8 28,7 44,5 28,7 70,0

55,5

4735

4736
21,6 21,6 85,5 49,8

28,7 44,5 28,7 70,0

60,0

251

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4732/33, 4735/36
Variants
Order Number 4732.0000 4735.0000 4733.0000 4736.0000 Color black black black black Max. cable diameter 8.5 mm 10.0 mm 8.5 mm 10.0 mm

APPLIANCE COUPLERS

Max. wire size 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG 3 x 1 mm / 3 x 18 AWG 3 x 2 mm / 3 x 14 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

100 Pcs

Accessories

see page

278

252

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

P685

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

70 C

Description
- Rewireable connector, Screw-on version - Connector, Pin temperature 70 C, Protection class I - Cable

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 E following IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions

Variants
Order Number 4300.0401 Color black Max. cable diameter 8.5 mm Max. wire size 3 x 1 mm / 3 x 18 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

20 Pcs

253

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4300-06

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

C13

70 C

Description
- Rewireable connector: Screw-on version - Outlet, Pin temperature 70 C, Protection class I - Cable

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-2 C13 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions

Variants
Order Number 4300.0609 Color black Max. cable diameter 8.5 mm Max. wire size 3 x 1 mm / 3 x 18 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

45 Pcs

254

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4790, 4795

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4795

4790

C19

70 C

Description
- Rewireable connector: Screw-on version - Outlet, Pin temperature 70 C, Protection class I - Cable

Characteristics
- Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 21 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 C19 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I

Allowable operation temp. Protection class

Dimensions 4795

4790

Variants
Order Number 4795.0000 4790.1100 4790.1200 Color black black black Max. cable diameter 10.0 mm 8.7 mm 10.0 mm Max. wire size 3 x 2 mm / 3 x 14 AWG 3 x 1.5 mm / 3 x 16 AWG 3 x 2 mm / 3 x 14 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

100 Pcs

Accessories

see page

278

255

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4789, 4796

APPLIANCE COUPLERS
Actual information about approvals can be found on http://www.schurter.com/approvals

4796

4789

70 C

Description
- Rewireable connector: Screw-on version - Connector, Pin temperature 70 C, Protection class I - Cable

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 21 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Terminals Materials: Housing Appliance-inlet /-outlet Cable Thermoplastic, black, UL 94V-0 I acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I

Allowable operation temp. Protection class

Dimensions 4796

4789

Variants
Order Number 4796.0000 4789.1100 4789.1200 Color black black black Max. cable diameter 10.0 mm 8.7 mm 10.0 mm Max. wire size 3 x 2 mm / 3 x 14 AWG 3 x 1.5 mm / 3 x 16 AWG 3 x 2 mm / 3 x 14 AWG

Max. torque for screws: Terminal: 0.5 Nm, Cable clamp: 0.3 Nm, Cover: 0.3 Nm Cord retaining clamp see accessories

Packaging unit

100 Pcs

Accessories

see page

278

256

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

DISTRIBUTION UNITS

VERTEILLEISTEN

257

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SELECTOR CHART

DISTRIBUTION UNITS

Ratings Panel mounting

10 A / 250 VAC Snap-in front-side Wires

16 A / 250 VAC Screw-on front-/rear-side

10 A / 250 VAC

10 A / 250 VAC Snap-in front-side

Terminals for Product picture

Stand alone module

Wires

Type Line switch Fuseholder Voltage selector Comment

0712

4730

4741

0909

Inlet/outlet-module

Outlets shuttered

Line filter Protection class Catalogue page Ratings Panel mounting I 259 10 A / 250 VAC Snap-in front-side Wires Stand alone module Stand alone module I 260 10 A / 250 VAC I 261 10 A / 250 VAC I 262

Terminals for Product picture

Type Line switch Fuseholder Voltage selector Comment

4752; 4754; 4758 2-pole

4747; 4748

4740 5 x 20, 1-pole

with carrier frame for accessory moduls

Outlets shuttered

Line filter Protection class Catalogue page I 264 I 268 I 270

258

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0712

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

70 C

Description
- Panel mount: Snap-in version from front side - 2 Functions: Connector, Outlet, Pin temperature 70 C, Protection class I - Quick-connect terminals 4.8 x 0.8 mm

Characteristics
- Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 10 A / 125 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Quick-connect terminals 4.8 x 0.8 mm Solder terminal on request Snap-in 0.8 mm to 2 mm Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions

A = 1,3 - 2: X = 50,5 + 0,1 A = 0,8 - 1,2: X = 50,3 + 0,1

Variants
Order Number 4300.0301 Type 0712 50 Pcs

Packaging unit

259

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4730

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

Rear side

C20

70 C

70 C

Description
- Panel mount: Screw-on version from front or rear-side - Connector, Pin temperature 70 C, Protection class I

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 16 A / 250 VAC; 50 Hz 20 A / 125 VAC; 60 Hz > 4 kVAC between L-N > 6 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP40 acc. to IEC 60529 from rear-side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Panel thickness s Materials: Housing Appliance-inlet /-outlet Screw-on: Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 C20 acc. to IEC/EN 60320-1 and J acc. to IEC/EN 60320-2-2, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions
53.00 27.50 25.25 5.00 33.95 min 3.40 31.00 10.00 45.00 1) 45.00
1) Orientation hole

25.95 min

R 4.50 max

Variants
Order Number 4730.0100 Panel mounting Screw-on 100 Pcs Panel thickness s [mm] 8

Packaging unit

260

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4741

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

C14

70 C

70 C

Description
- Stand alone module - 2 Functions: of 2 outlets, Connector, Pin temperature 70 C, Protection class I, shuttered

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 2.5 kVAC between L/N-PE (3 sec/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Materials: Housing Appliance-inlet /-outlet Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Dimensions
53,4

42,5

72,6

Shutter operation: shutters opened by plug insertion

Shutter operation: shutters closed when plug is removed

Variants
Order Number 4741.0000 Type 4741 50 Pcs

Packaging unit

261

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0909

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

70 C

Description
- Panel mount: Snap-in version from front side - 2 Functions: Module of 2 up to 7 outlets, Pin temperature 70 C, Protection class I - Solder terminals 3.2 x 0.8 mm

Characteristics
- Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- other panel thickness

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Solder terminals 3.2 x 0.8 mm Snap-in 1.5 mm tolerance +0.0/-0.1 Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions

262

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

0909
Variants
Order Number 0909.0001 0909.0011 0909.0021 0909.0031 0909.0041 0909.0051 Panel thickness s [mm] 1.5 1.5 1.5 1.5 1.5 1.5 120 Pcs Appliance outlet 2 3 4 5 6 7

DISTRIBUTION UNITS

Length L1 [mm] 51 75 99 123 147 171

Length L2 [mm] 48.3 72.3 96.3 120.3 144.3 168.3

Packaging unit

263

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4752, 4754, 4758

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

4752 Quadbloc

4754 Quadbloc + One

4758 Quadbloc + Two

70 C

Description
- Panel mount: Snap-in version from front side - 2 Functions [4752]; 3 Functions [4754]; 4 Functions [4758]: Module of 4 outlets, Pin temperature 70 C [4752]; with additional carrier frame for accessory modules [4754; 4758], Protection class I [4752]; Pin temperature 70 C [4754; 4758]; Protection class I [4754; 4758] - Solder terminals or quick connect terminals

Characteristics
- Busbar is of single piece (no soldering) [4752; 4758] - Insulation cover on the rear-side - Qualified for use in equipment according IEC/EN 60950

Other versions on request:


- for protection class II

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C from front side IP30 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Terminals Panel thickness s Materials: Housing Appliance-inlet /-outlet Solder terminals or quick connect terminals Snap-in1/1.2/1.5/2/2.5/3 mm tolerance +0.0/-0.1 Thermoplastic, black, UL 94V-0 F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Degree of protection Protection class

Dimensions Quadbloc 4752

Quadbloc + One 4754 Cut-out for 2 mm Snap-in Inlet

Panel cut-out 96,2 x 32,5 mm, corner radius max. 1 mm

Panel cut-out 122.1 x 32.5 mm, corner radius max. 1 mm With applicance inlet, type 6100

264

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4752, 4754, 4758

DISTRIBUTION UNITS

Quadbloc + Two 4758 Cut-out for 2 mm Snap-in Inlet

Panel cut-out 134 x 32,5 mm, corner radius max. 5 mm With power entry module, type 6200 or type 6220

265

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4752, 4754, 4758


Variants
Order Number 4752.3200 4752.8200 4752.4200 4752.5200 4752.6200 4752.7200 4752.3400 4752.8400 4752.4400 4752.5400 4752.6400 4752.7400 4752.3000 4752.8000 4752.4000 4752.5000 4752.6000 4752.7000 4754.3200 4754.8200 4754.4200 4754.5200 4754.6200 4754.7200 4754.3400 4754.8400 4754.4400 4754.5400 4754.6400 4754.7400 4754.3000 4754.8000 4754.4000 4754.5000 4754.6000 4754.7000 4758.3200 4758.8200 4758.4200 4758.5200 4758.6200 4758.7200 4758.3400 4758.8400 4758.4400 4758.5400 4758.6400 4758.7400 4758.3000 Panel thickness s Terminals [mm] 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1 1.2 1.5 2 2.5 3 1

DISTRIBUTION UNITS

Length [mm] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 138 138 138 138 138 138 138 138 138 138 138 138 138

Length L2 [mm] 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 122.1 134 134 134 134 134 134 134 134 134 134 134 134 134

Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm

266

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4752, 4754, 4758


Variants
Order Number 4758.8000 4758.4000 4758.5000 4758.6000 4758.7000 Panel thickness s Terminals [mm] 1.2 1.5 2 2.5 3

DISTRIBUTION UNITS

Length [mm] 138 138 138 138 138

Length L2 [mm] 134 134 134 134 134

Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm Solder terminals 4 x 0.8 mm and quick connect terminals 6.3 x 0.8 mm

Please note, all quadblocs are available in protection-class II upon request. Cord retaining clamp see accessories

Packaging unit

50 Pcs [4752; 4758]; 40 Pcs [4754]

Accessories

see page

278

267

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4747, 4748

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

Minibloc 4747

Minibloc 4748 with cable

C14

70 C

70 C

Description
- Stand alone module - 2 Functions: of 4 outlets, Connector [4747]; country specific cable and plug [4748], Pin temperature 70 C, Protection class I

Characteristics
- Qualified for use in equipment according IEC/EN 60950

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Materials: Housing Appliance-inlet /-outlet [4747] Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I

Allowable operation temp. Protection class

Appliance-inlet /-outlet [4748]

Dimensions Minibloc 4747

Minibloc 4748 with cable

Mounting holes for 3 mm screws on 135 mm centres Dimensions: 147 mm long x 44 mm wide x 37 mm high

Mounting holes for 3 mm screws on 135 mm centres Dimensions: 147 mm long, 45 mm wide, 43 mm high, with 2 meter cable and appropriate plug

268

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4747, 4748
Variants
Order Number 4747.0000 4748.0300 4748.1300 4748.2300 4748.3300 United Kindom BS 1363 A, 10A Continental Europe CEE7/VII (Schuko), 10A IEC/EN 60320-2-2/E, 10A North America NEMA 5-15A, 15A 30 Pcs [4747]; 10 Pcs [4748] Terminals

DISTRIBUTION UNITS

Version with inlet 2 m cable 2 m cable 2 m cable 2 m cable

Packaging unit

269

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4740

DISTRIBUTION UNITS
Actual information about approvals can be found on http://www.schurter.com/approvals

4740.3X00

4740.4X00

4740.6X00

C14

70 C

70 C

Description
- Stand alone module - 2 - 4 Functions: Connector Protection class I, Outlet shuttered Protection class I, Line switch, Fuseholder with neon indicator

Technical data
Ratings IEC Ratings UL/CSA Dielectric strength 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 2.5 kVAC between L/N-PE (1 min/50 Hz) -25 C to 70 C Suitable for appliances with protection class I acc. to IEC 61140 Materials: Housing Appliance-inlet /-outlet Thermoplastic, black, UL 94V-0 C14 acc. to IEC/EN 60320-1, F acc. to IEC/EN 60320-2-2, UL 498 CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I 1-pole, acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Admissible power acceptance at higher ambient temperature see derating curves. Take note of the information on page 283 Rocker switch, illuminated, acc. to IEC 61058-1 Technical details see page 286

Allowable operation temp. Protection class

Fuseholder Power acceptance @ Ta > 23C

Line switch

Dimensions Stripbloc 4740.3X00

Stripbloc 4740.4X00

1) Version with plug and cable, see variants Mounting s for 3 mm screws

1) Version with plug and cable, see variants Mounting s for 3 mm screws

270

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

4740

DISTRIBUTION UNITS

Stripbloc 4740.6X00

Shutter operation: shutters opened by plug insertion

Shutter operation: shutters closed when plug is removed

1) Version with plug and cable, see variants Mounting s for 3 mm screws

Variants
Order Number 4740.4000 4740.4600 4740.4300 4740.6000 4740.6600 4740.6300 4740.3000 4740.3600 4740.3300 Appliance outlet 6 6 6 5 5 5 5 5 5 1-pole 1-pole 1-pole Continental Europe CEE7/VII (Schuko), 10A United Kindom BS 1363 A, 10A 2-pole 2-pole 2-pole Continental Europe CEE7/VII (Schuko), 10A United Kindom BS 1363 A, 10A Continental Europe CEE7/VII (Schuko), 10A United Kindom BS 1363 A, 10A Fuseholder Line switch Neon indication Terminals cable inlet 2 m cable 2 m cable inlet 2 m cable 2 m cable inlet 2 m cable 2 m cable

1) SP 5 x 20; 10 A / 250VAC, quick acting F, part No. 0001.1014 2) SP 5 x 20; 6.3 A / 250VAC, quick acting F, part No. 0001.1012 3) cable acc. countryspecific standards

Packaging unit

10 Pcs

271

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES

ACCESSORIES

VOLTAGE SELECTOR INSERTS

273

FUSE DRAWER "EXTRA-SAFE"

274

CONNECTION WITH STRANDED CABLE

275

BOWDEN CABLE

276

INSULATING COVER

277

CORD RETAINING KITS

278

272

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES
Voltage selector inserts for Power Entry Modules, types KE, CE, KG, CG

System No. 1

System No. 2

System No. 3

System No. 4

switch position 2 separate windings one with a tap 3 or 4 switch positions

switch position 2 separate windings 2 switch positionsa

switch position 3 separate windings 3 or 4 switch positions

switch position 2-pole change-over switch

Order Numbers for voltage selector insert for Power Entry Modules, types KE, CE, KG, CG System No. 4305.0048.00 4305.0048.01 4305.0048.03 4305.0048.05 4305.0048.10 4305.0050.00 4305.0050.02 4305.0050.04 4305.0050.06 1,2 1 2 2 1 3 3 3 3 Voltage marking, switch position 1 2 3 4 without marking 100 120 110 115 100 115 without marking 130 110 110 150 110 without marking 115 230 110 220 230 110 220 240 220 230 230 Schematic Switch position

20 110 115 15

100 110 115 100

120

115

240 240

220 220 220

20 20 40

110 110 110

110 110 110

4305.0049.00 4 4305.0049.07 4 4305.0049.17 4 4305.0049.19 4 Other voltage markings on request

273

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES
Fuse drawer Extra-Safe for Power Entry Modules, types KE, CE, KG, CG

Medical Fuse drawer

Order Numbers for fuses 5 x 20 mm 2-pole with shorting bar in the neutral side 1-pole 4305.0006 2-pole 4305.0001 4305.0021 1-pole 4305.0016 2-pole 4305.0011 for fuses 6,3 x 32 mm 2-pole with shorting bar in the neutral side 4305.0026

Order Numbers fuse drawer (Fingergrip and Extra-Safe) (to types KEA, KEA-Print, KFA, KM) Voltage markings for types Type 1-pole XX see table 1 KEA, KFA Fingergrip XX Extra-Safe without voltage selector KEA, KEA-Print, KFA (KM*) Fingergrip without voltage selector KEA, KEA-Print, KFA (KM*) Extra-Safe
* only 1-/2-pole

2-pole 4301.1014.XX 4301.1024.XX 4301.1401 4301.1403

1-pole + spare fuse case 4301.2814.XX 4301.2824.XX 4301.1409 4301.1411

2-pole with shorting bar in the neutral side 4301.3536.XX 4301.3537.XX 4301.1413 4301.1415

4301.1214.XX 4301.1224.XX 4301.1405 4301.1407

Table 1 Index XX 01 02 03 04 05 06 07 08 09 10 11 12 Voltage markings/terminal no 1 2 3 110 120 110 115 110 115 100 100 110 220 120 110 150 110 120 220 220 220 240 220 220 230 230 220 220 117 240 240 240 4 240 240

Table 1 Index XX 13 14 15 16 17 18 19 20 21 22 23 24 Voltage markings/terminal no 1 2 3 115 100 50 Hz 220 110 117 100 110 110 100 115 220 120 240 220 110 120 220 115 230 240 220 60 Hz 110 220 240 127 220 230 220 240 4 230 240

Other versions on request: for protection class II KEA with solder terminals Fuse drawer with other voltage values

Order Numbers for fuse drawer (Fingergrip and Extra-Safe) (to types KEC, KFC, KD, CD) Voltage markings Terminal no. 1 2 3 4 KEC 3 4 5 6 KD YY see following table YY without voltage selector without voltage selector Type 5 x 20 mm 1-pole Fingergrip Extra-Safe Fingergrip Extra-Safe 4303.2114.YY 4303.2124.YY 4303.2406 4303.2408 2-pole 4303.2014.YY 4303.2024.YY 4303.2401 4303.2403 2-pole with 6,3 x 32 mm shorting bar in the neutral side 1-pole 4303.2036.YY 4303.2037.YY 4303.2411 4303.2413 4303.2614.YY 4303.2624.YY 4303.2906 4303.2908 2-pole with shorting bar in the neutral side 4303.2536.YY 4303.2537.YY 4303.2911 4303.2913

2-pole 4303.2514.YY 4303.2524.YY 4303.2901 4303.2903

274

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES
Index YY 00 01 02 03 04 05 06 07 08 09 10 11 Voltage markings/terminal no 1 3 100 110 110 110 115 117 100 110 V 220 115 110 2 4 120 150 220 220 117 220 120 3 5 220 220 220 240 230 240 220 220 V 240 240 220 4 6 240 240 KEC KD Index YY 12 13 14 15 16 17 18 19 20 21 22 23 Voltage markings/terminal no 1 3 115 100 100 100 100 115 115 220 100 100 100 100 2 4 230 110 117 115 120 120 120 120 120 110 3 5 240 220 220 230 230 230 240 240 230 220 220 120 4 6 240 240 240 240 230 230 KEC KD

Other versions on request: for protection class II Fuse drawer with other voltage values

Accessory connection with stranded cable for KE, CE and KG, CG (wiring of voltage selector)

Quick connect terminals 4,8 x 0,8 mm

The connection with stranded cable has to be mounted by customer. Stand = 1,5 mm Attention: To guarantee the minimum air and creeping distances, use taps only for terminal 3/4 or N for KE, CE 2 / 3 / 4 or N for KG, CG (concerns voltage selector system 1, 2 and 3).

0881.0076 (length = 70 mm) 0881.0077 (length = 100 mm) Tap 4,8 x 0,8 mm

0881.0074 (length = 70 mm) 0881.0075 (length = 100 mm)

Order Numbers for connection with stranded cable Power entry Voltage selector modules type System No. 1 KE, CE 1-pole KE, CE 2-pole KG, CG 1-pole KG, CG 2-pole 0881.0075 0881.0076 0881.0074 0881.0076 0881.0075 0881.0076 0881.0074 0881.0076

Voltage selector System No. 2 and 3 0881.0074 0881.0075 2x 0881.0074 0881.0074 0881.0075 2x 0881.0074

Voltage selector System No. 4 0881.0076 0881.0077 2x 0881.0076 0881.0076 0881.0077 2x 0881.0076

275

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES BOWDEN CABLE


for type KD/KG, CD/CG Order details and description How to specify length of Bowden cable: R Mounting parallel to direction of actuation B1 Actuating part B2 Power entry module Dimensions in mm (center of mounting hole [B1], outer surface to center of mounting hole [B2], outer surface) R a/ b/ c/ Remote Actuator Technology The remote actuator cable assembly consists of a wire cable inside of a plastic insulated spiral wire casing. Identifying a proper routing of the cable assembly is important. Deviations from line to line placement will require bends in the cable with resulting losses in the overall assembly. These inefficiencies show up as friction losses and lost motion. Frictional losses are increases in actuation force due to losses in the assembly. Lost motion is an undesirable difference between the input end of the assembly and the output end. The principle element of lost motion is backlash and deflection. Backlash is caused by the wire cable moving inside the casing with the change in direction of motion. It is the function of clearance between the wire cable and casing, plus the number of degrees of bend in the cable assembly. Deflection of the cable assembly, while usually low, can be minimized by anchoring the casing. This is especially true in those applications of cable assemblies with long lengths and/or large degrees of bend in the system. All of these losses and resulting inefficiencies can be reduced by the equipment designer through minimizing the total degress of bend in the assembly. Because of the number of variables effecting proper operation of any remotely actuated switch assembly, it is important that the ordering instructions be used to determine proper cable length and to provide samples for customer approval. Consult figure for minimum information required to describe cable assembly application.

S Mounting 90 to direction of actuation B1 Actuating part B2 Power entry module Dimensions in mm (center of mounting hole [B1], outer surface to center of mounting hole [B2], outer surface) S a/ b/ c/

Ordering example The following 3 positions are necessary to place an order: 1. Order No. socket KD14.4199.151 2. Order No. fuse drawer 4303.2024.03 3. Bowden cable (type of mounting / dimensions in mm) *R a/200 b/180 c/40 * The Order No. for a customer specific Bowden cable youll get with the acknowledgment. Delivery time for a customer specific Bowden cable sample approx. 2 weeks. Standard Bowden cable sample, Order No. 0886.0101, ex stock Bowden cable assembly instruction Drop Bowden barrel into seat of switch Slide clamp around cable

Bowden cable locked into assembly

Type R

Type S Percent increase in actuation force

Degrees of bend in assembly

276

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES
Insulating cover The terminals of the Schurter appliance couplers can be protected against unintentional contact by the use of an insulation cover. They are made of flexible thermoplastic (UL 94V-0, black) and can be easily mounted from the rear to the corresponding appliance couplers. Order Numbers suitable for 0859.0047 KEA (without KEA-Print) KEB I, DC11, DC12, KFB1 6200, 6202, 6205, 6220 6600, 472X, 4793, 4798 6100, 6102 KEC, KFC KD, 6145 KEB II, KFB II KE, KMF, EC11 CD CE CG, KG, EF11 8843-FL, 8843-FLR

0859.0048 0859.0072 0859.0074 0859.0075 0859.0076 0859.0077 0859.0108 0859.0109 0859.0086

Cover GSF1

Order Number 0098.0078

Cord retaining kits For protection against loosening or accidental disconnection of the plug connector. Can also be mounted later. The correct kit type (A-M) for each combination of fixed and free components is shown in the selection chart on page 172. The corresponding Order No. for each kit type is shown in the smaller chart. Horizontal flanged components are secured to the panel using the kit supplied. Vertical flanged or snap-in components require additional drilling for the cord retaining kit as shown in the diagrams below. Each cord retaining kit consists of: 1 Stainless steel retaining clip 2 Nickel plated brass pillars 2 Nickel plated brass nuts 2 Nickel plated beryllium copper crinkle washers Order Numbers 4700.0001 4700.0002 4700.0003 4700.0004 4700.0005 4700.0006 4700.0007 4700.0008 4700.0009 4700.0010 4700.0011 4700.0012 Kit type A B C D E F G H J K L M

Cut-aways or countersinks on pillars to face inwards.

277

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

ACCESSORIES
Accessories

Cord retaining kits Selection Chart


KEB I / KFB I / DC 11 / DC 12 screw-on
Appliance inlet or outlet

KEB I / DC 11 / DC 12 snap-in

4721 screw-on

5110 screw-on

5200 screw-on

5220 screw-on

6100 screw-on

6110 screw-on

6200 screw-on

6220 screw-on

6600 screw-on

KEB II / KFB II

6100 snap-in

6110 snap-in

6200 snap-in

6220 snap-in

6600 snap-in

472x snap-in

KEA snap-in

4754 / 4758

4781.0000 4781.0100 4782.0000 4782.0100 4732.0000 4735.0000 4795.0000 4796.0000

C A B A B A A A A A C A E G B D F E E G G H E G L K C B B C A

A B A B A D E F G M J A

96,2 (4752) 122,1 (4754) 134,0 (4754) 13,0 24,0 24,0 24,0 12,0

42,0

Inlet end of cut-out Montageloch-Kante fr Gertestecker

Outlet end of cut-out 32,5 Montageloch-Kante fr Gertesteckdose 16,6

Inlet end g of cut-out Kante fr Gertestecker

42,6 Additional drilling for Kit H when used with 4754 and 4758 Additional drilling for Kits E and G when used with 4752, 4754 and 4758 Additional drilling for Kit M

16,1

Inlet end of Montagelochcut-out Kante fr Gertestecker

3,4 / Typical 12,4 12,0

36,0 Additional drilling for Kit A

42,0 Additional drilling for Kits E and G when used with 472x and 6600 snap-in

45,0 Additional drilling for Kit L

278

www.schurter.com

EC, EF, EG

KEC / KFC

KFS / KFX

Plug or connector for cable

4798 screw-on / C20F

KEA / KFA screw-on

FELCOM / 54/64

KG / CG

KD / CD

KE / CE

4707

4752

4793

0723

KM

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION

GENERAL PRODUCT INFORMATION

PRODUCT STANDARD / DEFINITIONS / CE-MARKING / CONFORMITY

280

NATIONAL APPROVALS

281

ELECTRIC PROTECTION

282

FUSEHOLDER

283

TECHNICAL DATA TO LINE SWITCHES

286

POWER ENTRY MODULES WITH LINE FILTER

288

279

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


PRODUCT STANDARD EQUIPMENT STANDARD
The product standard only contains minimum requirements. Attention is drawn to the fact that appliance specifications might contain requirements additional to or deviating from those specified in the relevant product standards. Schurter products are covered by the low voltage directives 72/23/EEC and 93/68/EEC. Those are valid for equipment and appliances with rated voltage values between AC 50 V to AC 1000 V as well as DC 75 V to DC 1500 V. The CE marking of Schurter parts will be found on the label of the smallest packing unit. On request we will submitt a CE conformity statement for each component. CE conformity statements and approvals can also be retrieved from the internet under www.schurter.com.

COMMENTS ON DEFINITIONS USED


Please be aware that the specifications nominal value used in the German part of the Schurter catalogue and the data sheets, is synonymous with rated value. The difference between these two values is a pure matter of definition. In order to avoid any unnecessary complications we will continue to use the specifications nominal value.

CONFORMITY TO COMPONENT STANDARDS, NATIONAL APPROVALS


National testing institutions are testing according to national and international standards or other generally recognized rules of technology. Their certification/approval-marks confirm the observance of the safety requirements which electric appliances must fulfil.

CE MARKING ACC. TO EU-DIRECTIVES


CE marking is the only marking which indicates that a product conforms to the relevant EU-directive. This means that the CE-mark is no quality or standard conformity mark but only an administration mark.

NATIONAL APPROVALS
(Recognition) (Listing) UL Underwriters Laboratories (USA) SEMKO NEMKO Underwriters Laboratories (USA, Canada) DEMKO CSA CSA SEV ASE (Mark) VDE Canadian Standard Association, Component Acceptance Service Canadian Standard Association Schweizerischer Elektrotechnischer Verein Association Suisse des Electriciens IMQ Verband Deutscher Elektrotechniker (Mark) European Norms Electrical Certification CCC China Compulsory Certification Instituto italiano del marchio di qualit FIMKO VE KEMA Danmarks Elektriske Materielkontrol Finnish Electrical Inspectorate sterreichischer Verband fr Elektrotechnik Keuring van Elektrotechnische Materialien Svenska Elektriska Materielkontrollanstalten Norges Elektriske Materiellkontroll BSI British Standard Institute

(Recognition) UL
C US

(Listing)

(Certificate of conformity with factory surveillance)

280

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


In addition to UL and CSA approvals, most of the SCHURTER components are also approved by one, two or more European Certification Bodies. This procedure was necessary, because the safety standards and the regulations were different for most of the European Countries. During the last few years, however European countries have made numerous efforts to eliminate these national deviations and to harmonize these standards to a common European Safety Standard. Per definition a European Standard carries with it the obligation, to be implemented at national level by being given the status of a national standard and trough the withdrawal of any conflicting national standard. For almost the entire SCHURTER product range, European Standards such as there exist. And with every European Standard that a component has to fulfil the definition of requirements is defined. Furthermore, the test requirements are harmonised and the framework is established for the test report in English With this harmonized procedure, the test for safety of the component is completely independent of the Certification Body that was chosen for testing. Furthermore, it makes no sense to test the same component according to the same procedure at several different Certification Bodies. For the above mentioned reasons, SCHURTER has decided to reduce the variety of European Approvals and to test each component at only one European Certification Body. For those cases where one of our components has actually more than one European Approval, only one of these will be maintained in future. The others will not be renewed once they have expired. Because UL and CSA are not members of the CENELEC, the standards of UL and CSA are not harmonized yet with the European Standards. However, UL and CSA are trying to harmonize their standards with each other. Where possible, SCHURTER will apply for the combined cULus approval. Scope These standards apply to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV. Object The object of these standards is to give: a) Definitions for degrees of protection provided by enclosures of electrical equipment as regards: 1. Protection of persons against access to hazardous parts inside the enclosure 2. Protection of the equipment inside the enclosure against ingress of solid foreign objects 3. Protection of the equipment inside the enclosure against harmful effects due to the ingress of water. b) Designations for these degrees of protection. c) Requirements for each designation. d) Tests to be performed to verify that the enclosure meets the requirements of these standards. Designations The degree of protection provided by an enclosure is indicated by the IP Code in the following way: Arrangement of the IP Code:

IP DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)


Standards IEC 60529, EN 60529

IP Code letters First characteristic numeral Second charactesristic numeral

US

or

But in any event, SCHURTER will continue to keep the two approvals from UL and CSA in future.

281

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


Elements of the IP Code and their meanings A brief description of the IP Code elements is given in the following chart. Element Numerals or letters Meaning for the protection of equipment Meaning for the protection of persons

Code letters

IP

First characteristic numeral 0 1 2 3 4 5 6 Second characteristic numeral 0 1 2 3 4 5 6 7 8

Against ingress of solid foreign objectif /

Against access to hazardous parts with /

(non-protected) 50 mm diameter 12,5 mm diameter 2,5 mm diameter 1,0 mm diameter dust-protected dust-tight Against ingress of water with harmful effects

(non-protected) back of hand finger tool wire wire wire

(non protected) vertically dripping dripping (15 tilted) spraying splashing jetting powerful jetting temporary immersion continuous immersion

PROTECTION AGAINST ELECTRIC SHOCK


1. Protection against direct and indirect contact General terms The protection against electric shock on electric equipment as well as their components are divided into the following parts: Protection against direct contact with live parts concerns all measures for the protection of human beings and animals against hazards which result from direct contact with live parts of electric equipment and their components. Protection against indirect contact is the protection of human beings and animals against hazards which result from contact of live parts 1 of electric equipment as well as components thereof, which have become live due to an insulation failure.
1

Protection class 0

Main protective measures 1. Basic insulation between live parts and accessible conductive parts. 2. Earth-free location, non-conducting environment. 1. Basic insulation between live parts and accessible conductive parts. 2. Means are provided for the connection of accessible conductive parts of the equipment to the protective (earthing) conductor in the fixed wiring of the installation in such a way that accessible conductive parts cannot become live in the event of a failure of the basic insulation. 1. Basic insulation between live parts and accessible conductive parts. 2. Additional insulation. Basic and supplementary insulation are summarised under the term double insulation. Under certain circumstances also a reinforced insulation (single insulation system) may guarantee an equivalent protection against electric shock as a double-insulation does. No terminal for a protective conductor is allowable. A possibly existing protective conductor must not be connected and has to be insulated like any live part. 1. Functional insulation. 2. Supply at safety extra-low voltage SELV (the circuit is isolated from the mains supply by such means as a safety isolating transformer). The protection against electric shock is in this case completely based on the supplying by SELV-circuits (U 42 V). Higher voltages are not generated in the equipment. No terminal for a protective conductor is allowable.

II

Accessible, conductive part, which is not conductive normally but which may be conductive due to a failure.

2. Protection against direct contact with live parts e.g. of a fuseholder The data sheets of the relevant components inform about the taken measures. 3. Protection against indirect contact Measures for the protection against indirect contact on electrical equipment are defined according to IEC 61140 by the 4 protection classes 0, I, II, III. Each protection class includes two protection measures. Even if one of these measures should fail, no electric shocks will occur.

III

282

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


IEC CONNECTORS
Appliance couplers approved according IEC 60320 are designed as two pole appliance couplers for alternate current with or without protective conductor with a rated voltage of 250 V and a rated current of 16A for technical application that are desired for interconnection to flexible cords of electrical equipment for power supply of 50Hz or 60Hz. Appliance couplers according mentioned standard are suitable for operation under environmental temperatures of normally 25 C and do not have to exceed 35 C. Appliance couplers are designed for use without especial moisture protection. So the design of the appliance needs to assure ingress protection if it is designed to be used under these circumstances. Following figures need to be respected in order to meet standard IEC 60320: Rated voltage: 250 VAC Rated current according type: 0,2A, 2.5A, 6A, 10A, 16A The appliance couplers are separated according the maximum operation temperature at the base of the connector pin: Pin temperature up to 70C: Appliance couplers for cold condition Pin temperature up to 120C: Appliance couplers for warm condition Pin temperature up to 155C: Appliance couplers for hot condition The Appliance couplers are separated according the categories of equipment: Appliance couplers for appliances according protection class I Appliance couplers for appliances according protection class II The protection classes are described in standard IEC 61140 Appliance couplers will be additionally separated according the connection method to a flexible cord: Rewireable connectors Non-Rewireable connectors It is not possible to touch any live parts on the SCHURTER fuseholders when the fuse-carrier is extracted. Extra-safe handling with SCHURTER power entry modules Protection against contact with live parts is an important aspect when dealing with electrical connecting devices. Both your customers and your servicing engineers will appreciate the greatest possible protection against accidental contact with live parts something which can easily happen as a result of inappropriate use, or during servicing or repair work. In particular, our shock-safe, extra-Safe fuse-drawers and protective covers precautions are effective ways of protecting against accidental contact when using the power entry modules. Example: Power entry module with fuseholder, shocksafe category PC2

Closed fuseholder and appliance inlet.

According to IEC

FUSEHOLDERS, PART OF A POWER ENTRY MODULE


Explanations, thermal requirements, selection criteria 1. Protection against electric shock (against direct contact with live parts) for fuseholders The assessment of the protection against electric shock assumes that the fuseholder is properly assembled, installed and operated as in normal use, e.g. on the front panel of the equipment. IEC 60127-6 and EN 60127-6 divides into three categories:

When a fuse-link 5 x 20 mm or 6,3 x 32 mm (1/4 x 11/4) is inserted or replaced, neither the fuse nor the fuse-carrier can come in contact with any live parts.

The Extra-Safe versions of shock-safe power entry modules are now available. They are thus also able to satisfy requirements of the following standard: IEC 60601-1 (medical equipments)

CateFeatures gory PC1 Fuseholders without integral protection against electric shock. They are only suitable for applications where corresponding additional means are provided to protect against electric shock. PC2 Fuseholders with integral protection against electric shock live part is not accessible: when the fuseholder is closed after the fuse carrier (incl. fuse-link) has been removed either during insertion or removal of the fuse carrier (incl. fuse-link) Compliance is checked by using the standard test finger specified in IEC 60529. PC3 Fuseholder with enhanced integral protection against electric shock The requirements for this category are the same as those for category PC2, with the exception that the testing is carried out with a rigid test wire of 1 mm diameter according to IEC 60529, table VI, instead of the standard test finger.

The drawer can only be extracted with the aid of a tool (e.g. screwdriver) so that opening by hand is quite impossible. With some types it is also necessary to pull out the mains outlet first. Only then can the drawer be removed from the socket. The drawer can then be opened by hand.

283

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


2. Thermal requirements of the fuseholder 2.2 Rated current of a fuseholder The value of current assigned by the manufacturer of the fuseholder and to which the rated power acceptance is referred. 2.3 Rated power dissipation of the fuse-link (power dissipation at rated current) See sep. catalogue fuses. 2.4 Rated power acceptance and admissible temperatures of a fuseholder. The rated power acceptance of a fuseholder is determined by a standardised testing procedure according to IEC 60127-6. It is intended to be the power dissipation caused by the inserted dummy fuse-link at the rated current of the fuseholder and at an ambient air temperature of TA1= TA2 = 23 C (over a long period). During this test the following temperatures must not be exceeded on the surface of the fuseholder:

2.1. Influencing factors The design engineer of electrical equipment is responsible for its safety and functioning to humans, animals and real values. Above all, it is his task to make sure that the state of the art as well as the valid national and international standards and regulations be observed. In view of the safety of electrical equipment the selection of the most suitable fuseholder is of great importance. Among other parameters, one has to make sure that the maximum admissible power acceptances and temperatures defined by the manufacturer are followed. Differing definitions and requirements in the most important standards for fuse-links and fuseholders are time and again origin for the incorrect selection of fuseholders. To equate the rated current of a fuse-link with the rated current of the fuseholder, may, especially at higher currents, cause high, not admissible temperatures, when the influence of the power dissipation in the contacts of the fuseholder was not taken into consideration. For a correct selection the following influence factors depending on the application and mounting method, have to be followed: 1. Rated power dissipation of the suitable fuse-link. 2. Admissible power acceptance, operating current and temperatures of the suitable fuseholder. 3. Differing ambient air temperatures outside and inside of the equipment. 4. Length and cross section of the connecting wire. 5. Heat dissipation/cooling, ventilation. Heat influence of adjacent components. 6. Frequency of electrical load alternation 7. Long time operation (>500 h) with load >0,7 IN

Fuseholder surface area

1. Accessible parts 1) 2. Inaccessible parts 1) Insulating parts

Maximum allowable temperature measuring points (see figure 1) C TS1 85 TS2


2)

NOTES: 1) When the fuse-holder is properly assembled, installed and operated as in normal use, e.g. on the front panel of equipment. 2) The maximum allowable temperature of the used insulating materials corresponds to the Relative Temperature Index (RTI) according to IEC 60216-1 or UL 746 B.

Front panel of the equipment

Cover of the equipment

TA1

TA1 = ambient air temperature, surrounding the equipment TA2 = ambient air temperature in the equipment TS1 = temperature of accessible parts on fuseholder surface TS2 = temperature of inaccessible parts on fuseholder surface

TS1

TS2

TA2

Illustration of temperatures experienced in practice

284

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


2.5 Correlation between operating current I, ambient air temperature TA1 and the power acceptance Ph of the fuseholder. This correlation is demonstrated by derating curves.

Example of a derating curve

2.5 2.0
admissible power acceptance Ph in Watt

I = operating current of the fuseholder In = rated current of the fuseholder

1.5 1.0 0.5 0.0 0

l = 1.0 In l = 0.7 In l = << In

85 C = TS1 max. = TA1 max

20

40

60

80

100

ambient air temperature TA1 in C

The derating curves demonstrate the admissible power acceptance of a fuseholder depending on the ambient air temperature TA1 for the following fuseholder operating currents: I << In, I = 0,7 In and I = 1,0 In. This power acceptance corresponds to the max. admissible power dissipation of a fuse-link.

Notes The adherence to the limits, indicated by SCHURTER, in particular the power acceptance limits at the corresponding ambient air temperatures and mounting conditions of the fuseholder, is important for the safety of the product. It is therefore necessary to observe the following notes. The reduction of the rated power acceptance of the fuseholder based on the different conditions at the mounting place etc. have to be determined by the design engineer responsible. Examples: ambient air temperature is considerably higher inside of an equipment than outside (TA2 > TA1) cross-section of the conductor, unfavourable heat dissipation heat influence of adjacent components Therefore, temperature measurements on the appliance under normal and faulty conditions are absolutely necessary.

285

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION Technical data to line switches


Line switch used by type CMF Technical data Electrical rating acc. to IEC/EN 61058-1 10 (4) A / 250 VAC, 10 000 switch operations 6 (4) A / 250 VAC, 50 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

6 A, 125250 VAC, 6000 switch operations (14) HP, 125 VAC (12) HP, 250 VAC Statement in ( ) at inductive load with p. f. 0,45

Inrush current acc. to IEC/EN 61058-1

capacitive 70 A, 34 ms continuous current 5 A 10 000 switch operations 3 mm

Contact gap

KM KMF PMM GRM1/2/4

Electrical rating acc. to IEC/EN 61058-1

10 (4) A / 250 VAC, 10 000 switch operations 6 (4) A / 250 VAC, 50 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

12 A, 125250 VAC, 6000 switch operations (13) HP, 125 VAC (12) HP, 250 VAC Statement in ( ) at inductive load with p. f. 0,45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 34 ms continuous current 5 A 10 000 switch operations 3 mm

Contact gap

KEB I KFB I

Electrical rating acc. to DIN/VDE 0630

12 (3) A / 250 VAC, 10 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Inrush current acc. to IEC/EN 61058-1 Contact gap

capacitive 20 A, < 5 ms continuous current 5 A 10 000 switch operations 3 mm

DC11 DC12 DC21 DC22

Electrical rating acc. to IEC/EN 61058-1

16 (4) A / 250 VAC, 10 000 switch operations 10 (4) A / 250 VAC, 50 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

16 A / 125250 VAC, 6000 switch operations (1) HP 125 VAC / (2) HP 250 VAC Statement in ( ) at inductive load with p. f. 0,45

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 3-4 ms 100 A, 3-4 ms continuos current 5 A 3 mm

Contact gap

286

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION Technical data to line switches


Line switch used by type KP01 KEB II KFB II KD CD KG CG 64 Felcom 54 Felcom Felcom single Module Technical data Electrical rating acc. to IEC/EN 61058-1 12 (4) A / 250 VAC, 10 000 switch operations 8 (8) A / 250 VAC, 50 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

15 A, 125250 VAC, 6000 switch operations (34) HP, 125 VAC (112) HP, 250 VAC Statement in ( ) at inductive load with p. f. 0,45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 70 A, 34 ms continuous current 5 A 10 000 switch operations 3 mm

Contact gap

KD CD KG CG

with Bowden cable

Electrical rating acc. to IEC/EN 61058-1

6 (4) A / 250 VAC, 10 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

6 A, 250 VAC, 10 000 switch operations 8 A, 125 VAC, 10 000 switch operations

Inrush current acc. to IEC/EN 61058-1

capacitive 36 A, < 5 ms continuous current 6 A 6000 switch operations 3 mm

Contact gap

EC11 EC12

Electrical rating acc. to IEC/EN 61058-1

16 (4) A / 250 VAC, 10 000 switch operations 10 (4) A / 250 VAC, 50 000 switch operations Statement in ( ) at inductive load with p. f. 0,6

Electrical rating acc. to UL 1054

20 A, 125250 VAC, 6000 switch operations (1) HP, 125 VAC (2) HP, 250 VAC Statement in ( ) at inductive load with p. f. 0,45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 34 ms continuous current 5 A 10 000 switch operations 3 mm

Contact gap

287

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


INDUSTRIAL MAINS FILTERS
Frequency range 0.01 MHz ... 1000 MHz General Information Electromagnetic Compatibility (EMC) is the capability of electrical equipment (installations, devices, assemblies) to operate effectively in its electromagnetic environment (Immunity), without in turn irresponsibly affecting this environment (Emission). Mains filters of various types are used for the protection of electronic circuits, components and equipment against transients, or similar interference, on the mains power supply. A suitable filter can be selected from the existing product range for each equipment type in accordance with electromagnetic conditions of its environment. Mains interference can be classified into four categories: A) Fluctuations in the industrial mains supply (magnetic voltage stabilizer) B) Harmonic wave interference in the frequency range 100 Hz ... 2 kHz (filter type selective harmonic) C) Transient interference signals in the frequency range up to 300 MHz (filter type low-pass) D) Sinusoidal interference signals in the frequency range up to 1 GHz (filter type broad band, low-pass) In practice, however, interference is mainly found in the last three categories B, C and D. Superimposed on the high-voltage mains supply, such interference can affect the performance of electronic circuits, or even cause them damage. An optimally-designed mains filter can perform a double function: 1st stage A differential mode acting filter with high energy absorption. Discharging resistors are normally used for Cx capacitors > 100 nF. The capacitors are tested and approved as so-called Class X noise suppression capacitors. The 1st stage serves as dl/dt limitation. 2nd stage A common mode acting filter with a high, broad band attenuation ratio. A ZNR varistor surge serves as the overvoltage suppression component. The earthed capacitors are tested and approved as so-called Class Y noise suppression capacitors. 3rd stage Common mode as well as differential mode acting filter in the HF range up to 300 MHz. Feedthrough capacitors make high attenuation values possible up to the gigahertz range. These capacitors are also Class Y type. SCHURTER uses only approved noise suppression capacitors according to EN 132400. Filter Assemblies Three types of mains noise suppression filter assemblies are used in practice: Collective Suppressor 3-stage filter

L Line

PE Line filter Figure 1

Function 1 The filter protects an electronic control circuit from voltage spikes in the mains supply, which may be generated, for example, by electromechanical switches and relays. Function 2 The same filter also acts simultaneously in the opposite direction. The HF interference generated in the unit by thyristor control is attenuated such that the boundary values Class B, (EN 55011/55022) are maintained. Filters are usually made up of capacitors and inductance coils. Components such as leakage resistors, surge dissipators and VHF chokes can also be integrated into the filter. Broad band filters which meet the highest requirements are often composed of 2 or 3 single stages put together to make one filter unit:

The collective suppressor principle results in one filter per plant. This has to cope with the entire power input. In addition, all of the connecting cables have to be shielded. Furthermore interference generated by A device can reach other devices for instance B or C through the connecting cables. The following example promises to be a more economical solution. In many cases, the single suppressor principle is the most economical solution.

288

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


Single Suppressors INTERFERENCE SUPPRESSION FILTERS prevent mains interference from affecting electronic equipment. They enable an interference-free operation even in the case of a power supply badly affected by mains interference. It is common to operate the mains filter in both directions in the one piece of equipment, allowing it to fulfil its double function as both interference and RF suppression filters as specified.

Common- and differential Mode Interference Filter engineering differentiates between common and differential mode interference originating from supply lines. Combined Single and Collective Suppressor From the technical point of view, only the combined application of both suppression techniques can result in a significant improvement. In the case of a non-earthed interference source, interference at first only propagates along the connecting lines. Like the mains AC current, the parasitic current flows to the user on one lead, and returns to the interference source on the other. Both these currents are in differential mode. This type of interference is therefore referred to as differential mode interference. Due to the mechanical configuration and its parasitic capacitance, parasitic currents are also generated in the earthing circuit. This parasitic current flows on both connecting leads to the user and over an earthed lead back to the interference source. Both currents on the connecting lead are in common mode. This type of interference is therefore referred to as common mode interference.

Interference Propagation In the field of interference and RF suppression, the most significant means of transmission is the direct electrical connection, i.e. the connecting wiring. The radiation coupling is also important from the electromagnetic compatibility (EMC) point of view; it cannot, however, be dealt with here. Interference Propagation

RF Suppression Chokes Current Compensated Chokes in Interference Suppression Filters

The capacitive and inductive coupling effects occur inside the case. These could be: Capacitive coupling through the coupling capacity of a mains transformer. Inductive coupling through control system wiring in parallel. The introduction briefly mentioned the possibility of the mains filter operating with a double function. Depending on the main area of application, these filters are designated as either RF SUPPRESSION FILTERS or INTERFERENCE SUPPRESSION FILTERS. The one filter may, therefore, appear under two references in the documentation. A filter is also classified by its mechanical design as well as its electrical data. RF SUPPRESSION FILTERS impede the propagation of RF interference, generated by an electronic or electrical device into the mains. They also ensure an interference-free radio reception in the immediate vicinity.

The main type of choke used in suppression filter engineering is the current compensated choke. This mainly damps the common mode interference. The differential mode parasitic current, or rather the magnetic flux they produce in the core, is compensated by means of a special type of winding. The relatively small attenuation of the differential mode parasitic currents can be balanced through the large, symmetrically connected capacitance Cx between the lines. Only the leakage inductance Ls of the choke is then of any importance. L leakage

L nominal 50

to

L nominal 100

The high nominal inductance LN active for common mode parasitic currents allows the insertion of small, earthed capacitances CY in a filter circuit. These capacitances are regulated by international standards for leakage currents.

289

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


RF Suppression Capacitors: General Information All SCHURTER filters are fitted with Class X or Y RF suppression capacitors in accordance with international standards (IEC, EN). These are mainly self-healing metallized paper or polyester types, tested against the standards of major countries around the world and approved as noise suppression capacitors. Class X capacitors are capacitors with unlimited capacity for those applications in which a failure caused by a short circuit cannot result in a dangerous electrical shock. Class Y capacitors are capacitors intended for an operating voltage Veff = 250 V with increased electrical and mechanical safety and limited capacitance. General notes a) Leakage current according to IEC 60335-1 The leakage current of a device is mainly determined by the capacity value of the Y-capacitor. According to international standards (IEC 60335-1 and VDE 0700 T. 1) the following regulations with respect to leakage current can be assumed: For electrical household appliance: N Type of appliance Protection class IL max. (mA) U (V) 250 250 250 250 250 f (Hz) 50 50 50 50 50 Medical filter Schurter medical filters comply with UL544 and IEC 60601-1 standard specifications and are available in two versions, which differ in terms of their leakage current values. Medical filter (M5) L L

Line

PE

PE

Load

N Medical filter (M80) L

Line

PE

PE

Load

Portable appliances Stationary motor appliances * Stationary heating appliances Appliances Appliances I,

I 0.75 I 3.5 I 0.75/kW (max. 5.0) II 0.25 0I, III 0.5

* Stationary appliances fixed or weighing in excess of 18 kg (without carrying handle). For other applications: Ref. UL Laboratory 0.5 mA (UL 1262) Medical 0.1 mA (UL 544) 0.1 mA (IEC 60601-1) IT 3.5 mA (UL 1950)
Test equipment

Standard medical filters for direct person contact supplied by Schurter have a leakage current value of <5 A (M5). This can only be achieved without Cy. Here, a common mode fault current against earth is not attenuated and the filter acts only on differential mode fault currents. In addition, an inlet in protection class II can be used here, as no earth connection exists. However, if an earth connection is desired, Type (M80) can be used for indirect person contact; this has a leakage current of <80 A which is below the required limit value of 0.1 mA. Type (M80) is manufactured to special order. Bleed resistor Medical filters and filters with a X-capacitor >100 nF have a bleed resistor so that no inadmissible rest voltage occurs at the touchable pins of the inlet.

5.0 mA (UL 1244)

IEC

3.5 mA 3.5 mA (IEC 60950) (IEC 61010-1)

Filter classification For easy reading of the catalogue data, SCHURTER uses the following simplified filter classification: Differential Mode and Common Mode Attenuation Attenuation value Standard 2050 dB Medium 4070 dB High 6080 dB Excellent 7095 dB

Leakage Current Classification Operating leakage current Medical <0.1 mA Standard <0.5 mA Industrial <5 mA Other >5 mA

Schurter supplies Medical filters with either or <5 A /<80 A.

290

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


EMC requirements in Europe Household, Luminaries and Telecommunication Residential, commercial and light industrial Emission IEC 61000-6-3 (EN 50081-1) EN 55022 ITE Information technology equipment EN 55014 Household Applications and Tools Harmonic (IEC 61000-3-2)* Voltage fluctuations (IEC 61000-3-3)* Immunity IEC 61000-6-1 (EN 50082-1) IEC IEC IEC IEC 61000-4-2 61000-4-3 61000-4-4 61000-4-5 ESD HF-Field Burst Surge Immunity IEC 61000-6-2 (EN 50082-2) IEC 61000-4-2 ESD IEC 61000-4-3 Inducted HF-Field (enclosure) IEC 61000-4-6 Inducted HF-Field (lines) IEC 61000-4-4 Burst IEC 61000-4-5 Surge IEC 61000-4-8 NF Magnetic Field (only for magnetic devices) Class Industrial (ISM) Industrial, Scientific and Medical Emission IEC 61000-6-4(EN 50081-2) EN 55011 Harmonics (IEC 61000-3-2)* Voltage fluctuation (IEC 61000-3-3)*

1) ISM radio-frequency equipment

Electrical Safety Regulations The most important safety standards for equipment/installations are listed in the following: IEC 60950 Safety of Information Technology Equipment including Electrical Business Equipment IEC 60335 Safety of Household and similar Electrical Appliances IEC 61010-1 Safety requirements for Electronic Measuring Appartus IEC 60601 Safety requirements for Electro-medical Equipment UL 1950 Safety requirements for Information Technology Equipment UL 544 Electric Medical and Dental Equipment Interference Emissions There are basically 2 types of emitted disturbances: conducted and radiated. Line interferences are high frequency noise signals which are superimposed on the useful signals on input and output lines. Interference signals can be of common- or differential mode type (see Chap. 1.4) The significance of line interference is reduced dramatically above a frequency of 30 MHz. From here radiated interference increases greatly. On the following pages we will nevertheless deal with conducted interference only. Measuring Technique CISPR 1 VDE 0875

Measuring Technique CISPR 3 VDE 0871

The main differences between the two measuring techniques lie in the fixing of the line impedance (artificial mains) and the test bandwidth used for the test receiver. In the case of CISPR 3 (VDE 0871) specific interference levels are set for the frequency range down to the low frequency range (10 kHz to 150 kHz). The trend in international organizations is towards replacing the CISPR 1 technique with the CISPR 3 technique, particularly with regards to the line impedance (150 to 50 OHM). These measurements can be made in the SCHURTER laboratories with the assistance of a EMC specialist in interference suppression. Radio Frequency Interference Boundary Values RFI testing station

291

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


EN 55011: Boundary values and measuring systems for RF suppression for industrial, scientific and medical high frequency equipment (ISM), 1991 (see also CISPR 11 or VDE 0871) Boundary values complying with EN 55011 EN 55013: Boundary value and measuring techniques for RF suppression characteristics of radio receivers and con EN 55014: Boundary values and measuring systems for RF suppression for electrical household appliances, handheld electrical tools and similar electrical products, 1993 EN 55015: Boundary values and measuring systems for RF suppression for fluorescent lamps and lighting, 1993 Harmonics (EN 61000-3-2, IEC 61000-3-2) Current harmonics represent a distortion of the normal sine wave provided by the utility. When a product such as an SCR switched load or a switching power supply distorts the current, harmonics at multiples of the power line frequency are generated. Two significant consequences arise as a result of harmonic generation. First, because of finite impedances of power lines, voltage variations are generated that other equipment on the line must tolerate. Second, when generated in a three-phase system, harmonics may cause overheating of neutral lines. Power line harmonics are generated when a load draws a non linear current from a sinusoidal voltage. The harmonic component is an element of a Fourier series which can be used to define any periodic waveshape. The harmonic order or number is the integral number defined by the ratio of the frequency of the harmonic to the fundamental frequency (e.g., 150 Hz is the third harmonic of 50 Hz; n = 150/50). After multiple postponement finishes at 1.1. 2001 the transition-period for the EN 61000-3-2, frequently called PFC-Norm. It applies to all electrical and electronic devices with input current up to max. 16 A per phase, which are designed to connect to the general lowvoltage mains. Limits are set only for 220/380 V, 230/400 V and 240/415 V at 50 Hz. This standard distinguishes four classes of equipment. Class Equipment A Simmetric three phase equipment and all other equipment not in other classes B Portable tools C Lighting equipment D Equipment having special Waveshape (see EN 61000-3-2, paragraph 4 picture 1) A harmonics test to conform to the standards must include an analysis of the incoming current up to the 40th harmonic (for fN = 50 Hz, fH = 2 kHz). The IEC 61642 "Industrial a.c. networks affected by harmonicsApplication of filters and shunt capacitors" give guidance for the use of passive a.c. harmonic filters and shunt capacitors for the limitation of harmonics and power factor correction intended to be used in industrial applications, at low and high voltages. Voltage Fluctuations (Flicker) (EN61000-3-3, IEC 61000-3-3, IEC 61000-3-5) The appearance of flicker effects and voltage fluctuations on the mains supply is caused by varying loads connected to the mains. The most critical are the effects of voltage fluctuations on equipment such as lights and illumination. Here the light output and thereby the intensity is an exponential function of the supplied voltage. This fluctuation in light intensity is called flicker. Many people experience dizziness and headaches as a result. There are various limit values depending on the type of voltage fluctuation (square, sinusoidal and mixed or erratic voltage fluctuation). Flickers are measured by so-called flicker meters (arranged in compliance with EN 60808).

Quasipeak (QP) and Average (AV) are two limits, neither of which must be exceeded and which are measured by two different test receivers. The test arrangement remains the same. These boundary values replace the boundary values given by the old standards for broadband and narrowband noise generators. Boundary values are divided into Class A and B. Into Class A fall those devices which should not be operated in residential buildings and should not be connected to power supplies which also supply these areas. Class A boundary values shall not be exceeded. Into Class B fall devices for which above restrictions do not apply. Class B boundary values shall not be exceeded. EN 55022: Boundary values and measuring systems for RF suppression for information technology installations (Telecommunications) 1987 (see also CISPR 22 or VDE 0878). Boundary values complying with EN 55022

Into Class A fall all units which should be used in a commercial environment and should be used with a safety distance of 30 m to other units. Into Class B fall all units which have no restrictions on their use.

292

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


Immunity ESD (Electrostatic Discharge) (EN 61000-4-2, IEC 61000-4-2) One of the main interference sources, along with switching through radio interference , is electrostatic discharge from people and equipment. Burst (EN 61000-4-4, IEC 61000-4-4) One of the most common and most dangerous sources of interference are transient disturbances such as those originating from switching transients (interruption of inductive loads, relay contact bounce, etc.). The burst test measures the resistance of the device to repetitive fast transients. Surge (EN 61000-4-5, IEC 61000-4-5) This test procedure measures the behaviour of a device when subjected to high-energy pulses. Sources of such pulses are switching events due to lightning strikes, short-circuits, or switching cycles which vary in time and place. Surge test on Schurter filters are according to EN 133200. Surge voltage form in open circuit Specification of the Burst test impulse

Guideline for the selection of ESD test levels Class Class Class Class Class 1 2 3 4 Relative ambient humidity as low as [%] 35 10 50 10 Antistatic material (floor) x x x x Synthetic material (floor) Level air discharge (kV) 2.00 4.00 8.00 15.00 Level contact discharge (kV) 2.00 4.00 6.00 8.00

Recommended test levels for Fast Transient/Burst Test levels Level 1 Well-protected environment The installation is characterized by following attributes Voltage peak: [kV] Power supply Signal ports 0.25 Repetition rate [kHz] 5.0

Suppression of all EFT/B* in the switched power supply circuits 0.50 Separation between power supply lines and control and measurement circuits Shielded power supply cables with the screens earthed at both ends Partial suppression of EFT/B* in the power supply and control circuits Separation of all the circuits from other circuits associated with environments of higher severity levels Physical separation of unshielded power supply and control cable from signal and communication cables No suppression of EFT/B* in the power supply and control circuits Poor separation of the industrial circuits from other circuits Dedicated cables for power supply, control, signal and communication lines Poor separation between power supply, control, signal and communication cables No Suppression of EFT/B* in the power supply and control and power circuits No separation between power supply, control, signal and communication cables Use of multicore cables in common for control and signal lines 1.00

Level 2 Protected environment

0.50

5.0

Level 3 Typical industrial environment

2.00

1.00

5.0

Level 4 Severe industrial environment

4.00

2.00

2.5

*EFT/B: Electrical Fast Transient/Burst

293

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


Installation classification for Surge Immunity test Class Class 0 well-protected environment Class 1 Partly protected environment Environment definition All cables with overvoltage protection Well-designed earthing system Surge voltage may not exceed 25 V All cables with overvoltage protection, well interconnected earth line network Power supply completely separated from the other equipment Surge voltage may not exceed 500 V Separate earth line to earthing system The power supply is separated from other circuits Non-protected circuits are in the installation, but well separated and in restricted numbers Surge voltage may not exceed 1000 V The installation is earthed to the common earthing system Protected electronic equipment and less sensitive electric equipment on the same power supply network Unsuppressed inductive loads are in the installation The installation is connected to the earthing system for the power installation Current in the kA range due to earth faults The power supply network can be the same for both the electronic and the electrical equipment Surge voltages may not exceed 2000 V Electrical environment for electronic equipment connected to telecommunication cables The interference voltages can be extremely high All cables and lines are provided with overvoltage protection Voltage peak [kV] L N [2]

L/N PE [12]

0.50

Class 2

1.00

0.50

Class 3

2.00

1.00

Class 4

4.00

2.00

Class 5

dep. on the local power supply network

dep. on the local power supply network

Permissible Working Current as a Function of Ambient Temperature Up to the approved nominal ambient temperature a the filter can be operated continuously at its nominal current. Above this temperature the square of the nominal current drops off linearly and reaches its zero point at Tmax (85 or 100 C). Derating curve (approx.)

RF Suppression Capacitor Complying with EN 132400 (VDE 0565.T1) All SCHURTER filters are equipped with components which have been tested and approved as RF suppression capacitors. The most important test data for RF suppression capacitors are: Capacitance Cx, Cy 20% for fM = 1 kHz Insulation resistance Ris between the capacitor terminals: for C > 0.33 F: Ris x C > 2000 s (time constant ) for C 0.33 F: Ris > 6000 MOhm Major voltage test and standards for CX and CY capacitors Country Standard C Rigidity Pulse Test 1.2/50 s Europe EN 132400 X1 IEC 60384-14.2 X2 Y1 Y2 IEC 60950 X1 (Equipment X2 Standard) UL 1414 4.3 UR VAC 4.3 UR VAC 4.0 kVAC 2.5 kVAC 2700 VDC, 60s 2121 VDC, 60s 4.0 2.5 8.0 5.0 4.0 2.5 kV kV kV kV kV kV

Admissible operating current in % of In

Ambient air temperature Ta in C

Figure 4
USA 2121 VDC, 60s

Formula:

I = In
I In Tmax Ta Tn

Tmax - Ta Tmax - Tn

UL 1283

2121 VDC, 60s 2545 VDC, 1s X Y 4.3 UR VAC 2(100 + 2 UR) min. 2250 VAC

50 Pulse, 10 kV, 1000 W

= admissible operating current at elevated ambient air temperature = rated current = max. allowable ambient air temperature Ta (85 C) = ambient air temperature = allowable ambient air temperature at rated current (40 C)

Switzerland SEV 1055

3.0 kV 5.0 kV

294

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


RF Suppression Chokes Conforming to EN 138100 (IEC 60938, VDE 0565.T2) All SCHURTER filters are fitted with chokes which satisfy the guidelines set down by international and national standards organizations. The most important test data for RF suppression chokes are: Maximum variation of inductance: Test frequency 30% / +50% for compensated 15% / +15% for linear and storage 1MHz 20% at L 10 H 100kHz 20% at 10 H < L 1 mH 10kHz 20% at 1 mH < L 50 mH 50 to 120 Hz 20% at L > 50 mH 0.1 mA 25C 3C 6000 MOhm Insertion Transmission Loss (common- and differential mode) A) In common mode measurements, the line and neutral conductors are measured with respect to earth. B) In differential mode measurements, the insertion transmission loss is measured between line and neutral through a balancing transformer; the earth wire is not used.

Test current: Test temperature: Insulation resistance Ris: Test voltages Chokes for AC

Between connections 4.3 UR VDC

Inner and outer insulation 2 UR + 1500 VAC, but at least 2000 VAC 2 UR + 1500 VDC Measurement Method The insertion loss D is defined as that loss which results when a four-pole network is inserted into an existing layout, having a surge impedance Z, assuming that the LHS and the RHS terminal impedances of the four-pole network are equal in magnitude and real, the insertion transmission loss and the overall loss are the same. The insertion transmission loss, in decibels, can be obtained as follows: DdB = 20 log (UG) 2 U2 In practice, the substitution method is still used because its main advantage is that the absolute value of the voltage does not need to be known. Four-pole network with real termination

DC

3 UR VDC

Temperature rise at nominal current: T = 60C Short-circuit strength: EN and VDE: not applicable SEV: 25 x IN (2 half-waves) Leakage Current (see also Chapter 1.6 RF Suppression Capacitors: General information) 1-Phase measuring Techniques Measurement of the leakage current (simplified). The leakage current is measured from every pole of the network: to all accessible metal parts to metal parts of protection class II equipment which is separated only by the base material from parts under voltage. The test is made with AC at 250 V / 50 Hz. Measurements are made in both switch positions (see diagram).

Substitution method for measurement of insertion transmission loss

Protection Class l: Devices are fitted with a special grounding conductor to provide protection against electrical shocks (L,N,PE wire cable). SCHURTER filters correspond to Protection Class I.

This conventional measurement method is being replaced more and more by the rational frequency domain method or by measurements using the spectrum analyzer. The principal method remains nevertheless the same. Though the measurement of insertion transmission loss under load (nominal current) is prescribed, in practice it presents some difficulties. Attenuation loss acc. to CISPR17 The attenuation loss A is defined as that loss, results when a filter is inserted into an existing layout, having a wave impedance Z. Assuming that the terminal impedance on the input and output side of the line filter are equal in magnitude and real, the attenuation loss and the overall attenuation loss are the same.

295

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

GENERAL PRODUCT INFORMATION


The attenuation loss, in decibels, can be obtained as follows: In asymmetric measurements, the line and neutral conductor are measured with respect to earth (ground terminal). In symmetric measurements, the attenuation loss is measured between line and neutral conductor through a balancing transformer. The ground terminal is not used. Voltage tests on noise suppression filters complying to EN 133200 (VDE 0565.T3) In compliance to the known standards of the IEC, EN, VDE and UL, the filters are tested as follows. In principle, these tests correspond to those of the RF suppression capacitors. EN 133200 Nominal voltage connections 150 UR 250 VAC 250 < UR 500 VAC 500 < UR 760 VAC Application Classes (IEC 60068-1) The aim of this standard is to create a basis for classification of telecommunication engineering electrical components according to application classes which correspond to their climatic and mechanical suitability. Example: 2. Upper temperature limit + 100C

Between 4.3 UR VDC 4.3 UR VDC 4.3 UR VDC

Inner and outer insulation C* 1 F C*> 1 F 1500 VAC or 2250 VDC 2 kVAC or 3 kVDC 3 kVAC or 4 kVDC 4.3 UR VDC 4.3 UR VDC 4.3 UR VDC

*) C is the capacity measured between the connection block to which the high voltage is connected for test. UL 1283 (Appliance filters) Nominal voltage UR 250 VAC

Between connection 1250 VAC or 1768 VDC

Between connection and case 1500 VAC or 2121 VDC

UL 1283 prescribe production-line test with lower voltages (UL tab. 41.2) Test duration 2 sec. for production test 60 sec. for types test The Schurter final production test has a duration of 2 sec. This test may not be repeated more than one time (i.e. incoming inspection at the customer). Any filter that has been under test for 60 sec. can not be commercially used (reduced life cycle).

296

www.schurter.com

1. Lower temperature limit 25C

25/100/21

3. Equipment ambient conditions 95% RHA*/21 days per year

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL
ARGENTINA E. Marcotegui & Co. Miguelettes 1644 1426 Buenos Aires Tel: ++54 +11 4786 4083 Fax: ++54 +11 4784 5370 emarcotegui@emyco.com.ar Farnell InOne Tel: ++1 300 361 005 www.farnellinone.com Fastron Technologies Pty. Ltd. 25 Kingsley Close, Rowville 3178 Victoria Tel: ++61 +3 9763 5155 Fax: ++61 +3 9763 5166 sales@fastron.com.au www.fastron.com.au Koloona Industries Pty. Ltd. Unit 2, 17 Pembury Road, Minto NSW 2566 Tel: ++61 +2 9820 52 33 Fax: ++61 +2 9820 52 44 admin@koloona.com.au www.koloona.com.au RS Components Tel: ++1 300 656 636 www.rswww.com AUSTRIA Burisch Elektronik-Bauteile GmbH Leopoldauer Strasse 29 1210 Vienna Tel: ++43 +1 277 200 Fax: ++43 +1 277 206 info@beb.co.at www.beb.co.at S. A. Clofis N. V. Brusselsesteenweg 525 3090 Overijse Tel: ++32 +2 657 1805 Fax: ++32 +2 657 2620 info@clofis.be www.clofis.be Fusi-Bras Rua Barretos 138, Alto da Moca CEP 03184-090 Sao Paulo Tel: ++55 +11 6601 3330 Fax: ++55 +11 6601 4308 fusibras@fusibras.com.br www.fusibras.com.br Comet Eelectronics 16, Tsar Samuil Str. 1000 Sofia Tel: ++359 +2 9155 8000 Fax: ++359 +2 9540 384 office@comet.bg www.comet.bg Allied Electronics 1701 Woodward St, Ste 108 ON K2C 0R4 Ottawa Tel: ++1 6132 281 964 Fax: ++1 6132 288 006 www.alliedelec.com Birde Marketing Inc. 111 Esna Park Dr., Unit 1 Ont. L3R1 H2 Markham Tel: ++1 905 4777 722 Fax: ++1 905 4777 813 toronto@birde.ca www.birde.ca Components Distributors, Inc. 1938 Fairbanks Ave ON K1H 5Y3 Ottawa Tel: ++1 613 523 2634 Fax: ++1 613 523 1313 www.cdiweb.com Ferrotronic Components, Inc. 278 Labrosse QC H9R 5L8 Pointe Claire Tel: ++1 5146 931 771 Fax: ++1 5146 931 605 www.ferrotronic.com Future Electronics 237 Hymus Blvd. QC H9R 5C7 Pointe Claire Tel: ++1 514 694 7710 Fax: ++1 514 695 3707 www.futureelectronics.com

AUSTRALIA

Irwin Industrial Agencies 50 E Beaver Creek Road ON L4B 1G6 Richmond Hill Tel: ++1 905 889 9100 Fax: ++1 905 886 1861 www.irwin-ind.com Newark InOne 1870 Sources Blvd., Suite 300 QC L5T 2E7 Pointe Claire Tel: ++1 514 426 6336 Fax: ++1 514 426 6327 www.newarkinone.ca Newark InOne 331 Consortium Court ON N6E 2S8 London Tel: ++1 519 685 4280 Fax: ++1 519 685 7104 www.newarkinone.ca Newark InOne 6375 Dixie Road, Suite 202 ON L5T 2E7 Mississauga Tel: ++1 905 670 2888 Fax: ++1 905 670 1019 www.newarkinone.ca PS Components 601 Magnetic Dr. Unit 34 ON M3J 3J2 Downsview Tel: ++1 416 665 9546 Fax: ++1 416 665 9594 www.pscomponents.com Sager Electronics 151 Superior Blvd, Suite 22 ON L5T 2L Mississauga Tel. ++1 800-SAGER-800 / ++1 888 724 3736 www.sager.com Wes-Garde Components Group, Inc. 6740 Davand Drive, Unit #2 ON L5T 2K9 Mississauga Tel: ++1 905 670 3100 Fax: ++1 905 670 3107 www.wesgarde.com CHINA (INCL. HONG KONG SAR) Chi Lick Schurter Ltd. 7/F., Lin Fung Centre, 184-186 Texaco Road Tsuen Wan, N.T. Hong Kong SAR P. R. China Tel: ++852 +2408 77 98 Fax: ++852 +2408 70 01 fuse@chilickschurter.com www.chilickschurter.com Farnell InOne Tel: ++852 2268 9888 www.farnellinone.com Future Electronics Tel: ++852 2420 6238 www.futureelectronics.com Qualtek Electronics Ltd. Room 1608-1613, Park-In Commercial Centre 56 Dundas Street Kowloon Hong Kong SAR P. R. China Tel: ++852 +2780 13 39 Fax: ++852 +2780 82 29 info@qualtekhk.com www.qualtekhk.com RS Components Tel: ++852 2421 9898 www.rswww.com Schurter Asia Pacific HQ Contact Office Level 21, HSBC Tower, 101 Yincheng East Road Pudong Shanghai 200120 P. R. China Tel: ++8621 +2890 3091 Fax: ++8621 +2890 3131 info@schurter.com.cn www.schurter.com Schurter Electronics China (Ltd.) LuXi Industrial Zone Gao Bu Town, Dong Guan Guang Dong 523283 P. R. China Tel: ++86 769 873 87 52 Fax: ++86 769 873 87 51 info@schurter.com.cn www.schurter.com

BELGIUM

BRAZIL

BULGARIA

CANADA

297

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

CROATIA

Elgo d.o.o. Selska c. 18 10000 Zagreb Tel: ++385 +1 370 1798 Fax: ++385 +1 377 8415 elgo@zg.tel.hr ENIKA spol. s r.o Ndrazn 609 509 01 Nov Paka Tel: ++420 +493 773 311 Fax: ++420 +493 773 322 enika@enika.cz www.enika.cz ESB Blansko - elektronick soucstky s.r.o. Svitavsk 23/872 678 01 Blansko Tel: ++420 +51 641 8726 Fax: ++420 +51 641 1988 esb@esb.cz www.esb.cz GM Electronic, spol. s r.o. Karlnsk nmest 6 186 00 Prague 8 Tel: ++420 +224 812 606 Fax: ++420 +222 321 194 gm@gme.cz www.gme.cz Schurter s.r.o. Mal Skla 190 46822 Zelezn Brod Tel: ++42 +0483 392 080 Fax: ++42 +0483 392 334 firma@schurter.cz www.schurter.com

Radialex BP 1001 69612 Villeurbanne Cedex Tel: ++33 +1 6092 3800 Radiospares Rue Norman King P.O. Box 453 60031 Beauvais Cedex Tel: ++33 +2 4018 8000 Rutronik 6, Mail de l'Europe 78170 La Celle Saint Cloud Tel: ++33 +4 7235 3172 Schurter S.A.S. Route de Chteauvillain 52210 Arc en Barrois Tel: ++33 +3 2502 5049 Fax: ++33 +3 2502 5657 contact@schurter.fr www.schurter.com Williamson Z.A. de la Bougrire P.O. Box 64 44980 Sainte-Luce-Sur-Loire Tel: ++33 +1 3008 3300 GERMANY Assmy + Bttger Electronic GmbH & Co. Am Sportplatz 12-14 26197 Huntlosen Tel: ++49 +4487 928 30 Fax: ++49 +4487 928 320 info@aundb-electronic.de www.aundb-electronic.de Beck GmbH & Co. Elektronik Bauelemente KG Eltersdorfer Strae 7 90425 Nuremberg Tel: ++49 +911 934 080 Fax: ++49 +911 934 0828 info@beck-elektronik.de www.beck-elektronik.de Brklin OHG Dsseldorf Hherweg 245 40231 Dsseldorf Tel: ++49 +211 906 7110 Fax: ++49 +211 906 7125 info@buerklin.de www.buerklin.de Brklin OHG Mnchen Schillerstr. 41 80336 Munich Tel: ++49 +89 558 75110 Fax: ++49 +89 558 75421 info@buerklin.de www.buerklin.de EVG Electro-Vertriebs- Gesellschaft Martens GmbH & Co. KG Trompeterallee 244-246 41189 Mnchengladbach Tel: ++49 +2166 550 80 Fax: ++49 +2166 550 890 info@evg.de www.evg.de Ettinger GmbH Ottostrae 5 85649 Hofolding Tel: ++49 +8104 662 30 Fax: ++49 +8104 662 399 info@ettinger.de www.ettinger.de Farnell InOne GmbH Keltenring 14 82041 Oberhaching Tel: ++49 +8961 393 939 www.farnell.com Ferdinand Merschjohann Menkebachweg 3 33335 Gtersloh Tel: ++49 +5241 904 620 Fax: ++49 +5241 904 622 contact@merschjohann-produkte.de www.merschjohann-produkte.de JK-electronic Jan Knebel e.K. Am Waldrand 60 15711 Zessen Tel: ++49 +3375 920 975 Fax: ++49 +3375 920 382 m.knebel@jkelectronic.de www.jkelectronic.de

CZECH REPUBLIC

DENMARK

ACTE Denmark A/S Skelmarksvej 4 2605 Broendby Tel: ++45 +46 900 400 Fax: ++45 +46 900 500 bc-electronics@acte.com www.actenc.com Farnell InOne www.farnellinone.com Honeywell Oy Control Products Ruukintie 8 02330 Espoo Tel: ++358 +9 348 0101 Fax: ++358 +9 348 01375 controlproducts.finland@honeywell.com

FINLAND

FRANCE

Comarel 136, rue du 18 Juin ZA des Mtiers - Bt. 6 95120 Ermont Tel: ++33 +1 3413 7280 Corel Zone Industrielle P.O.Box 24 45270 Bellegarde Del 22, rue des Dames P.O. Box 63 78340 Les Clayes Sous Bois Tel: ++33 +1 3956 1018 Direct 151-153, rue de Constantine P.O. Box 4012 76021 Rouen Cedex Tel: ++33 +1 3079 1760 Farnell InOne 745, avenue de l'Europe P.O. Box 426 69654 Villefranche sur Saone Cedex Tel: ++33 +3 4410 1500 Groupe E.T.N. 5, rue Nicephore Niepce P.O. Box 278 76305 Sotteville-les-rouen cedex Tel: ++33 +2 3210 2343 Mateleco Z.A.I. des Bruyres 3, Avenue Le Verrier 78197 Trappes Cedex Tel: ++33 +2 3291 5151 Qualisud 4, rue Mayotte LES ULIS 91955 Courtaboeuf Cedex Tel: ++33 +1 3013 7380

298

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

Mtron P.O. Box 1353 28819 Achim Tel: ++49 +421 305 60 Fax: ++49 +421 305 6119 info@muetron.de www.muetron.de Mtron Theodor-Barth Strae 30 28832 Achim info@muetron.de www.muetron.de RS Components GmbH Hessenring 13b 64546 Mrfelden-Walldorf Tel: ++49 +6105 401 234 Fax: ++49 +6105 401 100 rs-gmbh@rs-components.com www.rsonline.de Reichelt Elektronik Elektronikring 1 26452 Sande Tel: ++49 +4422 955 333 Fax: ++49 +4422 955 111 info@reichelt.de www.reichelt.de Repro Elektronik GmbH Robert-Bosch-Strasse 1 61267 Neu-Anspach Tel: ++49 +6081 4050 Fax: ++49 +6081 4051 00 info@repro-elektronik.de www.repro-elektronik.de Schlder GmbH Hauptstrasse 71 75210 Keltern-Weiler Tel: ++49 +723 693 960 Fax: ++49 +723 693 9690 Info@schloeder-emv.de www.schloeder-emv.de Schukat Electronic Daimlerstr. 26 40789 Monheim Tel: ++49 +2173 950 730 Fax: ++49 +2173 950 739 info@schukat.com www.schukat.com Schurter GmbH Elssser Strasse 3 79346 Endingen Tel: ++49 +7642 6820 Fax: ++49 +7642 8820 info@schurter.de www.schurter.com GREECE Dion Giannikos & Co. 4, Salaminosstr. 141 23 Likovrissi, Athens Tel: ++30 +2 10 2851 772 Fax: ++30 +2 10 2851 771 info@giannikos.com www.giannikos.com Dion Giannikos & Co. 45 Kivelis Street 111 46 Athens Tel: ++30 +10 213 7450 Fax: ++30 +10 291 1140 sales@giannikos.com HUNGARY Farnell InOne Tel: ++36 +13 199 805 www.farnellinone.com Future Electronics Tel: ++36 +12 240 510 www.futureelectronics.com World Components Ipari es Kereskedelmi Kft. Gardonyi u. 8 9200 Mosonmagyarvr Tel: ++36 +96 578 070 Fax: ++36 +96 578 077 woco@mail.matav.hu www.woco.hu INDIA Schurter Electronics (India) Pvt. Ltd. Plot 7, Road 5, Sardar Industrial Estate, Ajwa Road Vadodara 390 019 Gujarat Tel: ++91+265 256 94 59 Fax: ++91+265 256 94 48 info@schurter.co.in www.schurter.com

INDONESIA

P.T. Dayatama Senasataya Jalan Kepu Timur 219 10620 Jakarta Tel: ++62 +21 250 0239 Fax: ++62 +21 351 8347 hhwijaya@cbn.net.id Albas Electronics Ltd. 1, Hanofar Street 43662 Raanana Tel: ++972 +9 745 8880 Fax: ++972 +9 745 8881 albas@netvision.net.il www.albas.co.il Future Electronics Tel: ++972 +9 970 1414 www.futureelectronics.com

ISRAEL

ITALY

Kevin-Schurter S.p.a Via Venezia Giulia 10 20157 Milan Tel: ++39 +2 3320 0914 Fax: ++39 +2 3320 0917 info@kevin.it www.schurter.com Asuka Denshi K.K. 5-2-41 Toyookas Iruma-shi Saitama-ken 358-0003 Japan Tel: ++81 +42 965 2555 Fax: ++81 +42 965 2481 aska.cop@chive.ocn.ne.jp Schurter K. K. 1302 Shinsen cho 24-1 Shibuya ku 150-0045 Tokyo Tel: ++81 +3 5465 2062 Fax: ++81 +3 3441 2595 schurter@ma.rosenet.ne.jp www.schurter.com

JAPAN

KOREA

Daesung Electronics Co. Ltd. A-904/9F, Chung Ang, Circulation Complex 1258 Kurbon-Dong, Kuro-ku Seoul 152-721 Tel: ++82 +2 2616 47 82 Fax: ++82 +2 2616 47 84 common@n-daesung.co.kr www.n-daesung.co.kr ElectroCOM # 1204 Rosedale, Officetel 724 Suseo-Dong Gangnam-Gu Seoul 135-744 Tel: ++82 +2 3413 0144 Fax: ++82 +2 3413 0147 electrocom@empal.com Future Electronics Tel: ++82 +2 555 6736 www.futureelectronics.com Schurter Asia Pacific HQ Contact Office 21/F Seoul Finance Center 84 Taepyungro 1-ga, Chung-Gu Seoul 100-101 Tel: ++822 +2 3782 48 91 Fax: ++822 +2 3782 48 92 info@schurter.com.sg www.schurter.com

MALAYSIA

Farnell InOne Tel: ++60 +3 7873 8000 www.farnellinone.com Future Electronics Tel: ++60 +3 7803 7133 www.futureelectronics.com RS Components Tel: ++60 +3 5032 1133 www.rswww.com Schurter (S) Pte. Ltd. 7500A Beach Road # 15-311/312 The Plaza 199591 Singapore Tel: ++65 +6291 21 11 Fax: ++65 +6298 41 33 info@schurter.com.sg www.schurter.com

MEXICO

Allied Electronics Tel: ++1 915 593 6291 / ++1 956 548 1129 www.alliedelec.com

299

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

Avnet, Inc. Tel: ++1 800 408 8353 / ++1 480 643 5691 / ++523 33 134 2300 www.avnet.com Carlton-Bates, Co. Tel. ++1 888 280 7706 / ++81 8311 4448 www.carlton-bates.com Digi-Key Corporation Tel: ++1 800 DIGI-KEY www.digikey.com Future Electronics Tel: ++1 800 477 6668 / ++52 33 31 22 0043 www.futureelectronics.com Millenium Sales, Inc. Av. Mariano Otero #3431, 5to Piso - 1 Guadalajara, Jal CP 45060 Mexico Tel: ++55 +33 3818 4354 Fax: ++55 +33 3818 4349 carlos@millsales.com www.millsales.com Mouser Electronics Tel: ++1 800 346 6873 www.mouser.com/schurter Newark InOne Tel: ++1 800 463 9275 www.newarkinone.com.mx NETHERLANDS Alcom Electronics B.V. Rivium 1e straat 52 2909 LE Capelle a/d IJssel Tel: ++31 +10 288 2500 Fax: ++31 +10 288 2525 info@alcom.nl www.alcom.nl Farnell InOne Tel: ++31 +30 241 7373 www.farnellinone.com Future Electronics Tel: ++31 +76 544 4888 www.futureelectronics.com RS Components Tel: ++31 +23 516 6555 www.rswww.com NEW ZEALAND Farnell InOne Tel. ++800 908 080 www.farnellinone.com Future Electronics Tel. ++800 888 780 www.futureelectronics.com Schurter (S) Pte. Ltd. 7500A Beach Road # 15-311/312 The Plaza 199591 Singapore Tel: ++65 +6291 21 11 Fax: ++65 +6298 41 33 info@schurter.com.sg www.schurter.com NORWAY EG Components Norway AS Trondheimsveien 436 P.O. Box 126, Kalbakken 0902 Oslo Tel: ++47 +22 917 900 Fax: ++47 +22 917 901 info@egcomponents.no www.egcomponents.no Farnell InOne Tel: ++47 800 14670 www.farnellinone.com Future Electronics Tel: ++47 229 058 00 www.futureelectronics.com RS Components Tel: ++47 5275 4040 www.rswww.com PHILIPPINES Farnell InOne Tel: ++63 +289 23883 www.farnellinone.com Future Electronics Tel: ++63 +280 75092 www.futureelectronics.com RS Components Tel: ++63 +288 84033 www.rswww.com SOUTH AFRICA SLOVENIA SINGAPORE ROMANIA PORTUGAL POLAND

Schurter (S) Pte. Ltd. 7500A Beach Road # 15-311/312 The Plaza 199591 Singapore Tel: ++65 +6291 21 11 Fax: ++65 +6298 41 33 info@schurter.com.sg www.schurter.com Euro-Elektronika Sp. z o.o. ul. Marymoncka 71/13 01-802 Warsaw Tel: ++48 +22 817 8022 Fax: ++65 +22 864 1949 info@euroelektronika.pl www.euroelektronika.pl Semicon Sp. z.o.o. ul. Zwolenska 43 04-761 Warsaw Tel: ++48 +22 615 7371 Fax: ++48 +22 615 7375 info@semicon.com.pl www.semicon.com.pl Farnell InOne Tel: ++45 445 36644 www.farnellinone.com Future Electronics Tel: ++45 7640 8764 www.futureelectronics.com RS Components Tel: ++45 3816 9900 www.rswww.com Redislogar-Portugal S. A. Rua das Fisgas, 442 Cascaistock-Arm 2, Alcoito 2649-505 Alcabideche Tel: ++351 +21 460 7920 Fax: ++351 +21 460 0111 redislogar@redislogar.pt www.redislogar.pt Comet Eelectronics S.R.L Str. Grigore Ionescu Nr. 94 Bucharest Tel: ++40 +2124 320 90 Fax: ++40 +2124 340 90 office@comet.srl.ro www.comet.srl.ro Farnell InOne Tel: ++65 +6788 0200 www.farnellinone.com Future Electronics Tel: ++65 +6479 1300 www.futureelectronics.com RS Components Tel: ++65 +6865 3433 www.rswww.com Schurter (S) Pte. Ltd. Asia Pacific HQ 7500A Beach Road 199591 # 15-311/312 The Plaza Singapore Tel: ++65 +6291 21 11 Fax: ++65 +6298 41 33 info@schurter.com.sg www.schurter.com SLOVAKIA Elgo d.o.o. Selska c. 18 10000 Zagreb Tel: ++385 +1 370 1798 Fax: ++385 +1 377 8415 elgo@zg.tel.hr ESB Blansko - elektronick soucstky s.r.o. Svitavsk 23/872 678 01 Blansko Tel: ++420 +51 641 8726 Fax: ++420 +51 641 1988 esb@esb.cz www.esb.cz Retron CC P.O. Box 39448 2018 Bramley Tel: ++27 +11 786 0553 Fax: ++27 +11 440 8275 info@retron.co.za www.retron.co.za

300

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

SPAIN

Redislogar S. A. c/Lanzarote No.2 Poligono Industrial Norte 28700 San Sebastian de los Reyes (Madrid) Tel: ++34 +91 659 0063 Fax: ++34 +91 659 1436 redislogar@redislogar.es www.redislogar.es Acte AB P.O. Box 4115 171 Solna Tel: ++46 +84 452 800 Fax: ++46 +89 826 19 http://www.acte.se Arrow Nordic Comp. AB P.O. Box 67 164 94 Kista Tel: ++46 +85 626 5500 Fax: ++46 +85 626 5750 http://www.arrowne.com Bejoken AB P.O. Box 9503 200 39 Malm Tel: ++46 +40 949 400 Fax: ++46 +40 949 900 http://www.bejoken.se Elfa AB 175 80 Jrflla Tel: ++46 +85 809 4100 Fax: ++46 +85 809 4302 Modern Elteknik AB P.O. Box 22100 400 72 Gteborg Tel: ++46 +31 653 700 Fax: ++46 +31 229 963 http://www.modern-elteknik.se Schurter Nordic AB Edsvallabacken 12 Box 169 12323 Farsta Tel: ++46 +8 447 3560 Fax: ++46 +8 605 4717 info@schurter.se www.schurter.com Selga AB P.O. Box 103 125 23 lvsj Tel: ++46 +85 562 1300 Fax: ++46 +85 562 1360 Solar AB P.O. Box 311 401 25 Gteborg Tel: ++46 +31 636 219 Fax: ++46 +31 626 231 Svenska Elkjedan AB P.O. Box 3 334 2 Anderstorp Tel: ++47 +37 119 300 Fax: ++46 +37 119 325 Westcomp AB P.O. Box 13067 402 52 Gteborg Tel: ++46 +31 388 9060 Fax: ++46 +31 214 755

Grieder Bauteile AG 4002 Basel Tel: ++41 +61 271 5763 Fax: ++41 +61 271 5905 griederbauteile@datacomm.ch Grieder Bauteile AG Reuslistrasse 62 4450 Sissach Tel: ++41 +61 976 9595 Fax: ++41 +61 971 3338 griederbauteile@datacomm.ch Jaeger AG Murtenstrasse 350 3027 Bern Tel: ++41 +31 326 3030 Fax: ++41 +31 326 3040 mail@jaegerag.ch www.jaegerag.ch Meierhofer AG Ob. Bahnhofstrasse 5507 Mellingen Tel: ++41 +56 48190 00 Fax: ++41 +56 48190 01 info@meierhofer.ch www.meierhofer.ch Mel SA via ai Monti 6600 Locarno Tel: ++41 +91 751 2024 Fax: ++41 +91 751 6940 Milgary Allmendstrasse 28 2562 Port Tel: ++41 +32 331 2064 Fax: ++41 +32 331 1359 info@milgray.ch www.milgray.ch Radio Matriel SA av. des Baumettes 21 1020 Renens VD Tel: ++41 +21 635 1551 Fax: ++41 +21 635 2035 info@radiomaterial.ch Schurter AG Werkhofstrasse 8-12 Postfach 4769 6002 Lucerne Tel: ++41 +41 369 31 11 Fax: ++41 +41 369 33 33 contact@schurter.ch www.schurter.com Schurter Holding AG Werkhofstrasse 8-12 Postfach 4769 6002 Lucerne Tel: ++41 +41 369 31 11 Fax: ++41 +41 369 33 33 contact@schurter.ch www.schurter.com Timonta AG Via San Martino 20 6850 Mendrisio Tel: ++41 +91 640 07 00 Fax: ++41 +91 640 07 01 info@timonta.ch www.timonta.ch TAIWAN R.O.C. Daybreak International (Taiwan) Corp. 3F 124 Chung-Cheng Rd Shihlin Taipei Tel: ++886 +2 8866 1234 Fax: ++886 +2 8866 1239 day111@ms23.hinet.net www.daybreak.com.tw Farnell InOne Tel: ++886 +2 8692 6267 www.farnellinone.com Future Electronics Tel: ++886 +2 8861 5288 www.futureelectronics.com Solomon Technology Corp. No. 42, Sing-Zhong Rd., Nei-Hu District Taipei Tel: ++886 +2 8791 8989 Fax: ++886 +2 8791 9693 jammylin@solomon.com.tw www.solomon.com.tw

SWEDEN

SWITZERLAND

Abydos Electronic GmbH Gewerbestrasse 11 8162 Steinmaur Tel: ++41 +1 854 70 40 Fax: ++41 +1 853 32 58 Distrelec AG Grabenstrasse 6 8606 Nnikon Tel: ++41 +1 944 99 11 Fax: ++41 +1 944 99 88 info@distrelec.com www.distrelec.com Elcomp AG Quellenstrasse 2 8610 Uster Tel: ++41 +1 941 47 44 Fax: ++41 +1 940 10 39 elcomp@swissonline.ch www.elcomp.ch

301

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

THAILAND

Farnell InOne Tel: ++66 +2 935 6799 www.farnellinone.com RS Components Tel: ++66 +2 361 8400 www.rswww.com Solomon Technology Thailand Co., Ltd. 93/57, 5th Floor, The Modern Group Tower Chaengwatana Road Pakkred Nonthaburi 11120 Tel: ++66 +2 574 64 09 Fax: ++66 +2 982 98 19 info@solomon.th.com www.solomon.th.com

Schurter Ltd. Durban Road, Bognor Regis West Sussex, PO22 9RX Tel: ++44 +1243 810 810 Fax: ++44 +1243 810 800 sales@schurter.co.uk www.schurter.com Techna International Ltd. Techna House, 36 Metro Centre, Dwight Road Watford Hertfordshire, WD18 9YA Tel: ++44 +1923 222 227 Fax: ++44 +1923 219 700 sales@techna.co.uk www.techna.co.uk USA Allied Electronics Tel: ++1 800 433 5700 www.alliedelec.com Altex-Mar Electronics Tel: ++1 800 783 2589 www.altex-mar.com Avnet, Inc. Tel: ++1 800 735 5426 www.avnet.com Beyond Components Tel: ++1 800 971 4242 www.beyondc.com Brill Electronics Tel. ++1 510 834 5888 www.brillelectronics.com Carlton-Bates, Co. Tel: ++1 866 600 6040 www.carlton-bates.com Components Center Tel: ++1 800 598 0433 www.componentscenter.com Components Distributors, Inc. Tel: ++1 800 777 7334 www.cdiweb.com Dee Electronics, Inc. Tel: ++1 800 747 DEE1 www.dee-inc.com Digi-Key Corporation Tel: ++1 800 DIGI-KEY www.digikey.com Fuses Unlimited Tel: ++1 800 255 1919 www.fusesunlimited.com Future Electronics Tel: ++1 800 477 6668 www.futureelectronics.com Leeds Electronics Tel: ++1 800 733 1277 www.leedselectronics.com Leo J. Mahoney Co. Tel: ++1 614 798 8403 www.ljmahoneyco.com Masline Electronics Tel: ++1 800 Masline www.masline.com Master Distributors Tel: ++1 912 452 1229 www.masterdistributors.com Mouser Electronics Tel: ++1 800 346 6873 www.mouser.com/schurter Nedco Electronics Tel: ++1 800 605 2323 www.nedcoeletronics.com Newark InOne Tel: ++1 800 2 NEWARK www.newarkinone.com Nu-Way Electronics Tel: ++1 800 323 7957 www.nuway.net Onlinecomponents.com Tel. ++1 310 452 8516 www.onlinecomponents.com Poco Sales Tel: ++1 800 762 6725 www.pocosales.com

UK & IRELAND

Abacus Polar Abacus House, Bone Lane, Newbury Berkshire, RG14 5SF Tel: ++44 +1635 515 711 Fax: ++44 +1635 515 754 emap@abacus.co.uk www.abacus.co.uk Acal Radiatron Alpha Way, Egham Surrey, TW10 8RZ Tel: ++44 +1784 439 393 Fax: ++44 +1784 477 333 sales@acal-radiatron.com www.acal-radiatron.com Acal TC Lunsford Road Leicester, LE5 0HH Tel: ++44 +116 274 4444 Fax: ++44 +116 274 2236 enquiries@acaltc.com www.acaltc.co.uk Arrow Edinburgh Way, Harlow Essex, CM20 2DF Tel: ++44 +1279 626 777 Fax: ++44 +1279 441 687 catalogue@arrowuk.com www.arrow.com E. Preston (Electrical) Ltd. Broadway, Globe Lane Ind Estate, Dukinfield Cheshire, SK16 4UU Tel: ++44 +161 339 5177 Fax: ++44 +161 343 1935 sales@epreston.co.uk www.epreston.co.uk Farnell InOne Canal Road Leeds, LS12 2TU Tel: ++44 +113 279 0101 Fax: ++44 +113 387 5228 www.farnellinone.com Future Electronics Ltd. Future House, Poyle Road, Colnbrook Berkshire, SL3 0AA Tel: ++44 +1753 763 000 Fax: ++44 +1753 689 100 www.futureelectronics.com H-Squared Electronics Ltd. Conifer House, Old Bridge Way, Shefford Bedfordshire, SG17 5HQ Tel: ++44 +1462 851 155 Fax: ++44 +1462 815 187 sales@h-squaredelectronics.co.uk www.h-squaredelectronics.co.uk RS Components Ltd. Birchington Road P.O. Box 99 Northants, NN17 9RS Tel: ++44 +1536 201 201 Fax: ++44 +1536 445 965 rswww.com Relec Electronics Ltd. 6-7 Omega Centre, Sandford Lane, Wareham Dorset, BH20 4DY ++44 +1929 555 700 ++44 +1929 555 701 sales@relec.co.uk www.relec.co.uk Rowe Hankins Components Ltd. Power House, Parker Street, Bury Lancashire, BL9 0RJ Tel: ++44 +161 765 3000 Fax: ++44 +161 763 1421 sales@rowehankins.com www.rowehankins.com

302

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

SCHURTER INTERNATIONAL

Quail Electronics Tel: ++1 800 669 8090 www.quailelectronics.com RS Electronics Tel: ++1 800 366 7750 www.rselectronics.com Radar, Inc. Tel: ++1 800 282 2524 www.radarinc.com Sager Electronics Tel: ++1 800 SAGER 800 www.sager.com Schurter Inc. 447 Aviation Boulevard Santa Rosa CA 95403 Tel. ++1 +707 636 3000 Fax. ++1 +707 636 3033 info@schurterinc.com www.schurter.com Taylor Industrial Electronics Tel. ++1 262 241 4321 www.taylorwi.com Wes-Garde Components Group, Inc. Tel. ++1 800 554 8866 www.wesgarde.com

303

www.schurter.com

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

INDEX BY TYPES

0712 0720-FS/FP, 0721-PS/PP 0723 0724 0909 4300-06 4707 4719 4721, 4723 4730 4732/33, 4735/36 4740 4741 4747, 4748 4752, 4754, 4758 4781, 4784 4782, 4785 4787, 4788 4789, 4796 4790, 4795 4798, 4793 5110 5145 5200 5500 6100-3, 6100-4 6102-3, 6102-5 6110-3, 6110-4 6120-3, 6120-5 6130-56 6145 6200 6600-3, 6600-4 8842, 8843 8843.ZP30 8843-FL, 8843-FLR C20F CD CE CG CMF1, 2, 3 DC11 DC12 DC21 DC22 EC11 EC12 EF11 EF12 Felcom 54 Felcom 64 Felcom Components FKH, FKI FKHD, FKID FMAB FMAB-72 FMBB FMLB-09 FMLB-41 FMLB-51 FMW-150 FMW-41 304 www.schurter.com

FMW-52 FMW-55 FPP-01 FPP-02 FSS FSW GRF2 GRM1 GRM2 GSF1 GSF2 GSP1 GSP2 KD KE KEA KEB1 KEB2 KEC KFA KFB1 KFB2 KFC KFS, KFX KG KM KMF KP01 KPF P675/PC P685 PMM

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

INDEX BY ORDER NUMBERS

0040.5000.2-0040.5015 0909.0001-0909.0051 4300.0065, 4300.0066 4300.0076 4300.0097-4300.0098 4300.0100, 4300.0101 4300.0251 4300.0301 4300.0401 4300.0609 4300.5051-4300.5065 4301.0001-4301.3214 4301.5001-4301.6205 4302.0001-4302.0124 4302.2141-4302.2104 4302.5001-4302.5005 4302.5311-4302.5339 4303.0001-4303.1212 4303.5001-4303.5229 4304.4001-4304.4070 4304.5001-4304.5067 4307.3001-4307.4214 4707.1000-4707.2300 4719.3300-4719.8310 4721.0000-4728.0300 4730.0100 4732.0000-4736.0000 4740.3000-4740.6600 4741.0000 4747.0000-4748.3300 4752.3000-4758.8400 4781.0000-4784.0100 4782.0000-4785.0100 4787.1000-4788.8100 4795.0000-4790.1200 4796.0000-4789.1200 4798.9000-4793.8200 5110.0133.1-5110.1543.3 5145.0012.511-5145.3383.111 5200.0123.1-5220.1043.3 5411.1151.151-5432.6253.301 5500.0001-5500.1055.3 5500.2000-5500.2126 5500.2014-5500.2133 5500.2021-5500.2110 5500.2026-5500.2081 5500.2031-5500.2076 5500.2035-5500.2085 5500.2039-5500.2104 5500.2043, 5500.2044 5500.2045-5500.2047 5500.2048-5500.2050 5500.2051-5500.2057 5500.2058-5500.2063 5500.2064-5500.2066 5500.2068-5500.2071 6050.5510-6650.4530 6100.3100-6100.4330 6102.3100-6102.5330 6110.3100-6110.4330 6120.3100-6120.5330 6130.5610-6130.5630 6145.0012.001-6145.3436.001 6200.2100-6220.5330 6600.3100-6600.4330 6653.3100, 6653.3300 C20F.0001-C20F.0014 CDA4.4101.151-CD44.4199.151 CEA0.6100.151-CE66.5100.151 CGA0.6101.151-CG30.6199.151 CMF1.1011.12-CMF3.1134.12 305 www.schurter.com

8842, 8843 0909 8843-FL, 8843FLR 8843.ZP30 0720-FS/FP, 0721PS/PP 0724 P675/PC 0712 P685 4300-06 KFS, KFX KEA KFA KEB1 KEB2 KFB1 KFB2 KEC KFC FKH, FKI FKHD, FKID PMM 4707 4719 4721, 4723 4730 4732/33, 4735/36 4740 4741 4747, 4748 4752, 4754, 4758 4781, 4784 4782, 4785 4787, 4788 4790, 4795 4789, 4796 4798, 4793 5110 5145 5200 Felcom 54 5500 FPP-01 FPP-02 FMAB-72 FMLB-41 FMLB-09 FMLB-51 FMW-41 FMW-52 FMW-55 FMW-150 FSS FSW FMAB FMBB Felcom Components 6100-3, 6100-4 6102-3, 6102-5 6110-3, 6110-4 6120-3, 6120-5 6130-56 6145 6200 6600-3, 6600-4 0723 C20F CD CE CG CMF1, 2, 3

DC11.0001.001-DC11.0031.401 DC12.1102.001-DC12.5202.103 DC21.0021.1111-DC21.0024.1111 DC22.1111.111-DC22.9223.111 EC11.0001.002-EC11.0031.402 EC12.1101.001-EC12.3201.002 EF11.0022.0010.01-EF11.3197.0010.01 EF12.0034.2110.01-EF12.3297.2110.01 GRF2.0212.11-GRF4.0419.013 GRM1.1160.013-GRM1.1181.023 GRM2.1160.013-GRM4.5522.123 GSF1.0001.01-GSF1.5402.01 GSF2.1010.01-GSF2.2013.01 GSP1.8100.1-GSP1.9503.1 GSP2.9100.13-GSP2.9213.16 KD13.1101.105-KD14.4199.151 KE10.2100.105-KE16.5100.151 KG16.5101.109-KG15.6199.151 KM00.1105.11-KM01.1205.11 KMF1.1111.11-KMF1.1293.11 KP01.1012.01-KP01.1453.01 KPF0.1-KPF8.3

DC11 DC12 DC21 DC22 EC11 EC12 EF11 EF12 GRF2 GRM1 GRM2 GSF1 GSF2 GSP1 GSP2 KD KE KG KM KMF KP01 KPF

SUMMARY | INDEX BY TYPES | INDEX BY ORDER NUMBERS

With the catalogue Connectors no. 0165.0287, the catalogue no. 0165.0286 english/german become invalid. Technical change rights reserved.

306

www.schurter.com

You might also like