You are on page 1of 3

ENGG.NAME: B.S.P/B.R.

P
                    CHEMIE‐TECH INDUSTRIAL CONSULTANT, UAE. CHECKED BY: B.K.J
PROJ.NO.: 1022

DESIGN OF PAD FOOTING FOR MAIN PUMP HOUSE LOAD CASE= 6 FROM STAAD FILE
FY= 292 KN
MZ= 572 KN.M
INPUT DATA :
Column Size = 600 1300 mm Z
fy = 460 N/mm 2
fck = 30 N/mm 2 3800
cover= 50 mm
Total Axial Load P= 208.6 KN 1450
Fx= 1 (WORKING LOAD)
Moment, Mz= 408.6 KNm X 3500 X
600
Moment, Mx= 1 KNm
Bearing capacity of the soil= 220 Kn/m 2
Height of the pedestal from m 1450
2
top of footing upto G.L.=
Depth of foundation from G.L.= 2.65 m 1250 1300 1250
Height of the pedestal above m
0.2
ground level = Z
Unit weight of soil= 18 Kn/m 3 G.L. 0.2
For fck = 30, τbd= 1.5 N/mm 2

For fck Q= 4.14 2


m 1250 1300 1250 2.65
m
(a) Proportioning base size: 0.65
m
Working load from column,P= 208.57 KN 3.8
Self weight of footing (10%) = 20.86 KN
Total load = 229.43 KN

2
Area of footing required = 1.04 m 20.248
117.258
65.10

Lx Lz
Area of the footing provided = 3.8 X 3.5 Check for Overturning

2
A= 13.3 m Overturning Moment = 411.421429 kn.m
3
Zz= 7.76 m
3
Zx= 8.42 m Stabilizing Moment = 1737.4 kn.m

Asssume overall depth of footing = 650 mm


Depth of footing from G.L. = 2.65 m Stabilizing Moment = 4.2 > 1.5
Unit weight of soil = 18 Kn/m3 Overturning Moment
SAFE
Self weight of footing = 216.125 KN
Self weight of column = 39 KN
Weight of soil = 450.72 KN

Total load, P= 914.42 KN

Moment @ column face = 316.531 KNm

d required = 420 mm
D= 470 mm < 650 mm
Pmax Pmin
L (m) B(m) A(m 2) Z(m )
3 2
P/A(KN/m ) M/Z(KN/m )
2
2
(KN/m ) (KN/m 2)
3.80 3.50 13.30 8.42 68.75 48.50 117.26 20.25 Pmax OR Pmini=P/A + M z/Zzz
3.50 3.80 13.30 7.76 68.75 0.13 68.88 68.62 Pmax OR Pmini=P/A + M x/Zxx

2
About Z : Pmax = 117.258 < 267.7 KN/m
SAFE
2
Pmin = 20.248 > 0 KN/m
SAFE

2
About X : Pmax = 68.882 < 267.7 KN/m
SAFE
2
Pmin = 68.624 > 0 KN/m
SAFE

MOMENT STEEL :

Ultimate moment at face of column, Z

Muz= 187.20 KN.M 3800

Mux= 306.20 KN.M 1450

X 600 3500 X

Provide total depth = 650 mm 1450

Eff.depth provided dzz= 600 mm 1250 1300 1250


Eff.depth provided dxx= 590 mm
Z
2
Astz= 784.51 mm
Astmini.= .=0.18%
2
= 1170.00 mm
Provide 16 @ 150 1340
2
Astx= 1310.22 mm mm2 2 m
Astmini.= .=0.18% 2.65
2
= 1170.00 mm m
Provide 16 @ 150 1340
mm2 650 mm

-37.10 KN/m2

68.46
2
KN/m

2
33.74 KN/m
check for one-way shear
Critical section is taken at a distance d from face of column 650 3150

2
Design pre.at the critical section= Pcr = 50.41 KN/m -37.099 KN/m2

Design shear= 139.52 KN 68.463


2
KN/m
Pt prov.= 0.06

τuc = 0.20 KN/m2 2


50.41 KN/m
Shear resisted by conc.= τuc*Bf*d
= 415.20 KN
SAFE

CHECK FOR TWO-WAY SHEAR : 3800


950 950
Critical sec.for two way shear id d/2 from the face of the col. 300 Z 300

Perimeter at critical section= 6200 mm 1150


1450
2
Area resisting shear= 3720000 mm 300
3500 X X
Shear strength of conc.= 0.25*√fck 1200 600
τ'uc =
2
1.369 N/mm
Ks= 0.5 + βc 1450 1900
Ks= 0.96153846 > 1
Therefore, Ks= 1
τuc = Ks * τ'uc 1250 Z 1250
2
= 1.37 N/mm 1300

Shear resisited by conc.= 5094 KN

Uniform intensity of pressure= Pu/Af


2
= 23.52 KN/m

Design shear= 259.22 KN

SAFE

2
-37.099 KN/m

68.463
KN/m2

DEVELOPMENT LENGTH :
For φ = 16 mm
Development Length = φ x σs
4 x τbd
= 667.000 mm

Anchorage Available = 1200 mm


SAFE

CHEMIE-TECH INDUSTRIAL
0 1022-01-C-01-D-0012
CONSULTANT, UAE.

REV. DATE DRG. NO. DESCRIPTION CLIENT: GPS CHEMOIL LLC FZC
REFERENCE DRAWINGS/DOCUMENTS PROJECT: GPS CHEMOIL TERMINAL
DESIGN CALCULATIONS FOR
FOUNDATION FOR MAIN PUMP
TITLE HOUSE
DATE 19.02.09 PROJECT NO.: 1022
ISSUE FOR
0 19.02.09 BSP/BRP BKJ BKJ TENDER PREP. BSP/BRP DOCUMENT NO. REV.

REV. DATE PREP. CHKD APPD. DESCRIPTION CHECKED BKJ 1022-01-C-05-A-0002


0
DETAILS APPROVED BKJ

You might also like