Type
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Arrangement Coolant Condensate drainage Maintenance required Timer (Optional) cu.ft 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg
AD 230
5000 30 /24 hr 30 / 660 Watt 20 / 575 Watt 16.8 / 515 Watt 660 870 +3C to +32 C 75 230V/50Hz 31 x 26 x 10 40 R407c Hose connector
AD 250
6500 55 /24 hr 55 / 1000 Watt 35 / 900 Watt 23.5 / 820 Watt 1000 1000 +3C to +32 C 75 230V/50Hz 31 x 26 x 10 42
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany
Type
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Arrangement Coolant Condensate drainage Maintenance required Timer (Optional) cu.ft 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg
AD 420
3000 19.0 /24 hr 19.0 / 420 Watt 7.6 / 360 Watt 6.0 / 280 Watt 420 315 +3C to +32 C 50 230V/50Hz 20 x 13 x 14 13 On the Ground R134a
AD 430
4000 30.5 /24 hr 30.5 / 540 Watt 12.0 / 400 Watt 8.0 / 320 Watt 540 600 +3C to +32 C 53 230V/50Hz 23 x 13 x 15 20
Water Tank (8.31) or tube connector Empty container, check and change filters Yes
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany
Type
AD 580
cu.ft 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg 8500 78 /24 hr 78 / 1400 Watt 52 / 1200 Watt 35 / 1010 Watt 1400 820 +3C to +32 C 55 230V/50Hz 32 x 19 x 20 55 On the Ground R407c Water Tank (161) or tube connector Empty container, check and change filters Yes
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Arrangement Coolant Condensate drainage Maintenance required Timer (Optional)
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany
Type
AD 750
cu.ft 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg 6000 55.0 /24 hr 55.0 / 900 Watt 24.5 / 660 Watt 14.0 / 560 Watt 900 710 +3C to +32 C 53 230V/50Hz 35 x 20 x 19 42 On the Ground,two large casters, various handles R407c Water Tank (121) or tube connector Empty container, check and change filters Yes
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Arrangement Coolant Condensate drainage Maintenance required Timer (Optional)
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany
Type
AD 810
cu.ft 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg 10,500 105 /24 hr 105 / 1500 Watt 67 / 1300 Watt 50 / 1120 Watt 1300 1300 +3C to +32 C 60 230V/50Hz 40 x 25 x 21 70 Installed condensate pump. Max. height for pumping: 4 mtrs On the Ground, Four Large caster R407c Simple Check up of piping & Connections, Check & Change Filters Yes
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Condensate drainage Arrangement Coolant Maintenance required Timer (Optional)
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany
Type
AP 50
sq.mtr. 1/24 hr 1/24 h 1/24 h 1/24 h Watt m/h C dB(A) V/Hz Inches Kg 30 47 / 24 hr 47 / 770 Watt 52 / 670 Watt 24 / 630 Watt 770 Watts 875 +3C to +32 C 50 230V/50Hz 29 x 33 x 10 54 kg R134a
AP 70
50 66 / 24 hr 66 / 1050 Watt 34 / 920 Watt 32 / 870 Watt 1050 Watts 1000 +3C to +32 C 52 230V/50Hz 29 x 41 x 10 64 kg
Recommended Coverage (Indicative)* Extraction (30 C/80% RH) 30C/80% RH 20C/60% RH 10C/70% RH Max. power consumption Air circulation rate Working temperature range Noise Level Power supply Dimension (height/width/depth) Weight Arrangement Coolant Condensate drainage Maintenance required Timer (Optional)
Yes
*Guideline figures/based on experience **Based on DIN EN 810 Subject to technical changes Made in Germany