You are on page 1of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA SALLE DIVISION 6 WOOD, PLASTICS AND COMPOSITES SECTION 06 40 00 - Architectural Woodwork

June 2013

Project : Location : DIVISION 6

Proposed Two-Storey Jaime Hilario Integrated School Banawang, Bagac, Bataan WOOD, PLASTICS AND COMPOSITES Architectural Woodwork

La Salle

SECTION 06 40 00 PART 1 1.1

GENERAL

PROJECT INCLUDES: A B C Standing and running trim Casework Door frames and jambs (see section 08 14 00)

1.2

QUALITY ASSURANCE A. B. C. Conform to Architectural Woodwork Institute (AWI) - Architectural Woodwork Quality Standards. Conform to Woodwork Institute of California (WIC) Manual of Millwork. Fire-retardant Treatment 1 2 3 4 Lumber: AWPA C20, non-corrosive interior type Plywood: AWPA C27, non-corrosive interior type Particleboard: ASTM E 84, flame spread 20 or less. Fire retardant chemical shall provide protection against termites and fungal decay, shall be registered for use as a wood preservative

Formaldehyde Emission Levels: 1 2 Particleboard: NPA 8 compliance

High Density Fiberboard: NPA 9 compliance

Architectural Woodwork 06 40 00

Page 1 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA SALLE DIVISION 6 WOOD, PLASTICS AND COMPOSITES SECTION 06 40 00 - Architectural Woodwork June 2013
3 PART 2 2.1 Hardwood Plywood: HPMA FE Compliance

MATERIALS

PRODUCTS A Interior Standing and Running Trim 1 2 3 4 B Tanguile / Narra for Transparent / Opaque Finish Grade: Premium Baseboard: Provide for all floor and wall intersections as indicated on the Drawings or as determined by the Project Manager. Tanguile baseboard. Tanguile Cornices:

Interior Wood Casework 1 2 3 4 5 Tanguile / Narra for transparent and opaque finish Grade: Premium Face Style: Flush Frame Fabrication: Face Frame Grain Matching: Vertical

Casework Hardware and Auxiliary Materials 1 2 3 Hardware Standard: NSI / BHMA A 156.9 Hardware finish and base metal: Satin stainless steel Glass: Clear float glass, ASTM C 1036

Interior frames and Jambs 1 2 Tanguile / Narra Grade: Premium

Auxiliary Materials 1 2 3 4 Screws: FS FF-S-111 Nails: FS FF-N-105 Anchors: Type required for secured anchorage Provide all necessary hardware and fittings.

Factory Finishing 1 Transparent finish: Premium grade with dull-rubbed flat sheen

Architectural Woodwork 06 40 00

Page 2 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA SALLE DIVISION 6 WOOD, PLASTICS AND COMPOSITES SECTION 06 40 00 - Architectural Woodwork June 2013
3 3.1 EXECUTION QUALITY LUMBER A Lumber shall be of approved quality of the respective kinds required for the various parts of the work, well-seasoned, thoroughly dry and free from large, loose or unsound knots, saps, shakes or other imperfections impairing its strength durability or appearance. Framing lumber shall be of rough dimensions shown on Drawings. All exposed woodwork shall be smoothly dressed and well sand- papered.

B C 3.2

SCHEDULE OF LUMBER Use the following wood as required in the Drawings: A Yacal (kiln-dried) 1 Wood plate and other lumber embedded or in contact with concrete, masonry or plaster work, except those specified as pressure-treated with copper Chromate Arsenic Salt Solution type-C.

Guijo (kiln-dried) 1 For all door jambs and other wall openings with wood frames.

Apitong (pressure-treated with Copper Chromate Arsenic Salt Solution - CCA-C) 1 All frame work for double plywood partitions vertical and horizontal studs 50 mm x 76 mm, etc, where required.

Tanguile/Narra (Kiln-Dried) 1 2 3 All interior frame work for counters, cabinets, closets, and shelvings. Doors, etc. (Verify door details) All base board and other moulding requirements.

3.3

TREATMENT OF LUMBER A B Lumber shall be well seasoned and kiln-dried to maximum moisture content of 15% except Yacal which shall not be more than 12%. Lumber shall be pressure-treated with Copper Chromate Arsenic Salt Solution or approved equal. Accompany lumber with certificate from lumber company, certifying treatment amount, moisture percentage after kiln-drying.

Architectural Woodwork 06 40 00

Page 3 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA SALLE DIVISION 6 WOOD, PLASTICS AND COMPOSITES SECTION 06 40 00 - Architectural Woodwork June 2013
C 3.4 Surface in contact with masonry and concrete shall be coated with creosote.

PLYWOOD A Plywood Materials 1 2 All plywood shall be free from knots, splits and other open defects, with smooth surface suitable to receive finish. Marine, veneer plywood, 19 mm thick, three-ply Class C waterproofed for all bathrooms flushed door. Refer to Section 08 14 00 Wood Door & Frames.

3.5

WORKMANSHIP A. Rough carpentry shall be executed in best, substantial, workmanlike manner. Framing shall be erected true to line, levels and dimensions, squared, aligned, plumbed, well spiked and nailed, adequately braced and fitted, using mortise and tendon joints where practical. Millwork shall be accurately milled to details as approved in manner to allow free play of panels, avoid swelling, shrinkage, insure work remaining in place without warping, splitting, or opening of joints. Millwork shall not be installed until concrete and masonry work have been cured and will not release moisture harmful to woodwork.

B.

3.6

HARDWARE INSTALLATION 5 Provide all necessary hardwares and fittings. Hardware shall be carefully fitted and securely attached. Apply hardware in neat, workmanlike manner. Locks shall be tested, knobs tightened, and necessary adjustments be made to put entire job in good working order.

End of Section 06 40 00

Architectural Woodwork 06 40 00

Page 4 of 4