HARCO PVC IPS GASKETED FITTINGS

DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

TEE (GxGxG)
ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
A L

BELL SPECIFICATIONS
A B

Spigot O.D.

SIZE 1 2 2 3 4 6 8 10 12

STYLE H H H H H H H Fab Fab

A 3.17 3.27 3.38 3.52 4.10 4.57 5.16 5.75 6.15

B 2.42 2.52 2.63 2.77 2.99 3.46 3.90 4.70 4.90

C 2.8 3.3 3.8 4.5 5.9 8.3 10.4 11.5 12.0

Spigot O.D. 1.90 2.38 2.88 3.50 4.50 6.63 8.63 10.75 12.75

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings use SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plastic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available.

SIZE PART No. 1x1 112-150 2x1 112-215 2x2 112-220 2x1 112-251 2x2 112-252 2x2 112-255 3x1 112-315 3x2 112-320 3x2 112-325 3x3 112-330 4x2 112-420 4x2 112-425 4x3 112-430 4x4 112-440 5x5 112-550 6x2 112-620 6x3 112-630 6x4 112-640 6x6 112-660 8x4 112-840 8x6 112-860 8x8 112-880

STYLE F H H A H H A H H H H H H H F A H H H H H H
L

A 6.0 6.1 6.1 8.4 6.8 6.8 9.4 7.7 8.0 7.7 8.6 8.5 8.8 9.3 11.0 12.2 11.5 11.8 11.5 13.9 14.4 14.9

L 9.1 9.1 9.1 9.9 9.9 9.9 10.9 11.4 11.9 10.9 13.1 13.1 13.1 13.1 14.8 11.6 12.5 16.3 16.4 19.5 19.5 19.5

WT. (approx.) 1.0 1.3 1.4 1.4 2.0 1.7 2.5 2.8 3.1 2.8 4.3 4.9 4.9 5.6 10.0 2.8 3.0 11.0 12.3 18.7 19.3 21.3

REDUCER (SxG)

SIZE 2x1 2x2 3x2 3x2 4x2 4x2 4x3 5x4 6x3 6x4 6x5 8x6

PART No. 116-215 116-252 116-320 116-325 116-420 116-425 116-430 116-540 116-630 116-640 116-650 116-860

STYLE F F F F F F F F F H Fab H

A 2.8 3.4 3.7 4.2 4.7 5.0 4.7 5.8 7.0 6.9 7.0 9.0

L 7.0 7.0 7.9 7.4 10.0 8.3 10.1 7.8 9.0 8.0 10.0 9.3

WT. (appox.) 0.5 0.8 0.9 1.3 1.5 1.8 1.9 3.0 3.5 2.7 4.9 5.8

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION

P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-mail: sales@harcofittings.com
Form 138 4/30/01

HARCO PVC IPS GASKETED FITTINGS


DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

GASKET x FEMALE NPT ADAPTER


ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
L

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings use SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plastic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available.

SIZE 1 2 2 3 4 5 6

PART No. 132-015 132-020 132-025 132-030 132-040 132-050 132-060

STYLE Fab Fab Fab Fab Fab Fab Fab

A 2.7 3.3 3.8 4.5 5.8 7.0 8.1


L

L 5.7 6.1 7.3 7.5 9.4 10.5 12.1

WT. (approx.) 0.5 0.7 1.2 1.5 2.6 5.0 6.0

PE (Plain End) x MALE NPT ADAPTER

SIZE 1 2 2 3 4 6

PART No. 133-015 133-020 133-025 133-030 133-040 133-060

STYLE Fab H Fab Fab Fab Fab

A 2.2 2.6 3.3 4.0 5.0 7.3


L

L 5.2 4.1 6.3 6.9 7.5 9.8

WT. (appox.) 0.3 0.3 0.8 1.3 2.0 5.3

SPIGOT x GASKET ADAPTER


B

SIZE 1 2 2 3 4 5 6

PART No. 130-015 130-020 130-025 130-030 130-040 130-050 130-060

STYLE H H H H H F H

A 2.7 3.3 3.8 4.5 5.9 7.0 8.3

B 1.1 1.4 2.0 2.0 2.3 3.0 3.0

L 4.5 4.9 5.3 5.8 6.4 9.1 8.0

WT. (appox.) 0.3 0.5 0.7 0.9 1.7 3.0 3.8

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION

P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-mail: sales@harcofittings.com
Form 139 4/30/01

HARCO PVC IPS GASKETED FITTINGS


DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

SERVICE TEE (GxGxFIPT)(Treaded NPT Thread)


ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
L

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings use SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plastic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available.

SIZE PART No. 1x 151-153 1x1 151-154 1x1 151-155 2x 151-202 2x 151-203 2x1 151-204 2x1 151-205 2x1 151-206 2x 151-252 2x 151-253 2x1 151-254 2x1 151-255 2x1 151-256 2x2 151-258 3x 151-302 3x 151-303 3x1 151-304 3x1 151-305 3x1 151-306 3x2 151-308 4x 151-402 4x 151-403 4x1 151-404 4x1 151-405 4x1 151-406 4x2 151-408 6x 151-602 6x 151-603 6x1 151-604 6x1 151-605 6x1 151-606 6x2 151-608

STYLE FB F Fab HB H H H H HB HB H H H H HB HB H H H H HB HB H H H H HB HB HB HB H H
L

L 8.5 8.5 10.9 9.2 9.2 9.2 9.2 9.2 9.9 9.9 9.9 9.9 9.9 9.9 11.0 11.0 11.0 11.0 11.0 11.0 10.7 10.7 10.7 10.7 10.7 10.7 9.3 9.3 9.3 9.3 9.3 11.5

WT. (approx.) 0.8 0.8 0.8 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 3.1 3.1 3.1 3.1 3.1 3.1 5.8 5.8 5.8 5.8 5.8 5.8

SWING JOINT TEE (GxGxACME) (315psi rated)

SIZE PART No. 2x1 153-204 2x1 153-205 2x1 153-206 2x1 153-252 2x1 153-255 2x1 153-256

STYLE H H H H H H

A 4.5 4.5 4.5 4.4 4.4 4.4

L 9.2 9.2 9.2 9.6 9.6 9.6

WT. (approx.) 1.4 1.4 1.5 1.9 1.9 1.9

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION

P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-mail: sales@harcofittings.com
Form 140 4/30/01

HARCO PVC IPS GASKETED FITTINGS


DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

CAP (Gasket)
ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
L

CROSS (GxGxGxG)
L

SIZE 1 2 2 3 4 5 6

Poured concrete thrust blocks only. PART No. STYLE A L 149-015 Fab 2.8 5.3 149-020 H 3.3 3.7 149-025 Fab 3.8 6.4 149-030 Fab 4.5 6.7 149-040 Fab 5.9 7.6 149-050 Fab 7.0 10.0 149-060 Fab 8.5 9.8
L

WT. (approx.) 0.5 0.5 1.0 1.4 2.7 4.4 6.9

NON_PRESSURE WYE (GxGxG)


SIZE 1 2 2 3 4 PART No. 153-015 153-020 153-025 153-030 153-040 STYLE Fab Fab Fab Fab Fab L 11.6 12.1 14.3 15.1 17.9 WT. (approx.) 1.7 3.4 4.4 5.3 9.0

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings use SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plas tic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available. SIZE 3x3 4x4 PART No. 101-0303 101-0404 STYLE Fab Fab C 6.8 8.4 L 10.1 12.3 WT. (appox.) 5.0 10.0

GASKET x MALE NPT ADAPTER


Do not use joint restraint.
L

Size on size and reducing sizes of these adapters also available in Harco ductile iron. SIZE PART No. STYLE A L WT. (approx.) 1x1 131-012 Fab 2.8 6.0 0.5 1 131-015 H 2.8 4.3 0.5 2 131-020 H 3.3 4.6 0.5 2 131-025 H 3.8 4.8 1.2 3 131-030 H 4.5 5.0 1.5 4 131-040 Fab 5.9 8.5 2.8 5 131-050 F 3.0 6 131-060 Fab 8.3 10.9 10.3
CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION

P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-mail: sales@harcofittings.com
Form 141 4/30/01

HARCO PVC IPS GASKETED FITTINGS


DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

90 BEND (GxG)
ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
L B L

GASKET x FLANGE ADAPTER


L

SIZE 1 2 2 3 4 6 8

PART No. 154-015 154-020 154-025 154-030 154-040 154-060 154-080

STYLE A Fab 5.0 Fab 6.0 Fab 7.0 Fab 7.5 Fab 9.0 Fab 11.0 Fab 13.5

B 3.9 4.8 5.5 6.0 7.5 9.5 11.8

L 4.8 5.1 5.8 6.0 7.0 8.3 17.7

WT. (approx.) 0.8 1.2 1.7 2.4 6.0 12.0 20.0

SIZE PART No. 1 118-015 2 118-020 2 118-025 3 118-030 4 118-040 6 118-060 8 118-080

STYLE F H H H H H H

B 1.0 1.3 1.6 2.0 2.5 3.6 4.5


L

L 4.8 6.2 6.8 7.7 9.5 12.3 14.9

WT. (approx.) 0.6 0.8 1.3 1.8 3.8 9.0 16.3

45 BEND (GxG)

A B

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings us e SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plastic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available.

SIZE PART No. 1 122-015 2 122-020 2 122-025 3 122-030 4 122-040 6 122-060 8 122-080

STYLE Fab H H H H H H

A 5.8 5.3 6.1 6.6 8.4 11.3 13.8

B 0.9 0.6 0.7 0.9 1.1 1.6 2.0

L 9.1 7.8 8.3 9.1 11.0 13.6 15.8

WT. (appox.) 0.9 0.8 1.1 1.6 3.4 7.8 13.3

22 BEND

SIZE PART No. 2 124-020 2 124-025 3 124-030 4 124-040 6 124-060

STYLE Fab Fab Fab Fab Fab

B 2.0 2.0 2.3 2.6 4.3

WT. (approx.) 2.0 3.0 3.0 5.0 11.0

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION

P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-mail: sales@harcofittings.com
Form 142-5 4/30/01

HARCO PVC IPS GASKETED FITTINGS


DESIGN DATA
Applicable Standards Materials: Joints: Gaskets: Wall Thickness: NSF 14 Certification.

LINE COUPLING (w/ Stop)


ASTM D-1784, NSF 14 ASTM D-3139 ASTM F-477 SDR-21
A L

PLUG (Spigot)
L

SIZE 1 2 2 3 4 6 8

Poured concrete thrust blocks only. PART No. STYLE A L 144-015 Fab 2.7 5.2 144-020 H 3.0 2.7 144-025 Fab 3.4 5.3 144-030 H 3.8 3.5 144-040 H 5.0 3.5 144-060 H 6.8 5.4 144-080 H 8.9 6.4

WT. (appox.) 0.2 0.2 0.8 0.4 0.4 2.3 3.8

SIZE PART No. 1 108-015 2 108-020 2 108-025 3 108-030 4 108-040 6 108-060 8 108-080 10 108-100 12 108-120

STYLE H H H H H H H C C

A 2.8 3.3 3.8 4.5 5.9 8.3 10.4 11.5 12.0


L

L 6.5 6.7 7.0 7.2 8.3 9.3 11.1 11.5 12.0

WT. (approx.) 0.5 0.7 0.9 1.3 2.7 5.6 10.3 14.0 22.0

REPAIR COUPLING (No Stop) HARCO STYLE

NOTES: All lay lengths & weights are approximate and are subject to change without notice. Fabricated fitting configurations may vary. STYLE LEGEND: H ----- Harco style one piece molded. HB --- Harco style one piece molded, reduced by use of flush style thd x thd bushing. F ----- Flo style one piece molded. FB --- Flo style one piece molded, reduced by use of flush style thd x thd bushing. C --- Manufactured by Certain-Teed Corporation. A --- Assembled using one piece molded fitting with MIPT x Gasketed adapter or Spigot adapter for branch or BELL. Fab Fabricated using SCH-40 PVC fittings with Harco Spigot adapters (or pipe) solvent welded together. (See pressure rating warning on this page.) Warning: Cyclical pressure surges (WATER HAMMER) can reduce the life of PVC fittings. Where such conditions may exist, HARCO DEEP BELL DUCTILE IRON FITTINGS for IPS size PVC pipe should be considered. HARCO DEEP BELL DUCTILE IRON FITTINGS are available in sizes 1 through 12. Fab Style: These fittings use SCH-40 PVC fittings. SCH-40 PVC fittings do not have a long term pressure rating. See section 6.3.2 of ASTM D2466-97. Use of these fittings in pressure systems is at users risk. The use of anything but properly designed and installed thrust blocks will reduce the life of plastic fittings. Thrust blocks must be poured concrete only and sized for the soil conditions. Joint restraint products are available.

SIZE PART No. 1 109-015 2 109-020 2 109-025 3 109-030 4 109-040 5 109-050 6 109-060 8 109-080 10 109-100 12 109-120

STYLE H H H H H H H H C C

A 2.8 3.3 3.8 4.5 5.9 7.0 8.3 10.4 11.5 12.0

L 6.5 7.8 8.4 9.0 10.6 11.2 11.6 11.1 11.5 12.0

WT. (appox.) 0.5 0.7 0.9 1.3 2.7 4.1 5.6 10.3 14.0 22.0

REPLACEMENT GASKET HARCO STYLE

SIZE 1 2 2 3 4 6 8

PART No. 195.015 195-020 195-025 195-030 195-040 195-060 195-080

WT. (approx.) 0.1 0.1 0.1 0.1 0.2 0.3 0.3

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.