Catalog 195C

Pressure Relief Valves for Air, Steam, Vapor & Liquid Service
Built in conformance to ASME Code Section VIII for Air, Steam, and Vapor Service. Set pressures to 300 psig. Stainless steel body and trim.

Series 2850
Bill of Materials
Item No. Part Name Material 2850 & 2852 SA-479 Type 316 St. St. Or SA-351 Gr. CF8M St. St. SA-216 Gr. WCB Carbon Steel 316 St. St. Stainless Steel Carbon Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Wire/Lead Seal Stainless Steel See Selection Table Stainless Steel 316 St. St.

5 7

Body

Bonnet Disc Blow Down Ring Cap, Plain Screwed Stem Spring Adj. Screw Jam Nut Spring Button (Upper) Spring Button (Lower) Cap Gasket Grooved Pin Wire Seal Nameplate (not shown) Spring Blow Down Ring Lock Screw Blow Down Ring Lock Screw Gasket

8 11 2 9 13

3 4 5 6 7 8 9 10 11 12 13 14

15 6 10 12 4 1

15 16 17

Built in conformance to ASME Code Section VIII, Capacity Certified by National Board (Air, Gas and Steam4)

17 16

Valve Size Type Number 285003-M20 285004-M20 285006-M20


General Notes:

Inlet x Outlet 3/4 x 1 1 x 1 1/2 1 1/2 x 2

(Connections: MNPT x FNPT) Maximum Set Pressure, Maximum Set Pressure, psig1 barg1 +401F to -28.9C to +205C to -20F to +750F +204C +399C +400F 300 300 20.7 20.7

Selection Table

Maximum Back Pressures psig @ barg @ 37.8C 100F 50 3.45

Materials Body / Bonnet 316 St. St. / Carbon St. Spring1

316 St. St.

1. For high temperature range (+400F to +750F / +205C to +399C) change fourth digit of type number from "0" to "2". Example: 285003-M20 becomes 285203-M20. Spring changes to Chrome Alloy, rust proofed. 2. Type numbers shown designate valves with plain screwed caps. Test lever required for air, steam or hot water service (above 140F / 60C). For packed lever change the three digit type number suffix from "-M20" to "-M40". Example: 285003-M20 becomes 285003-M40. 3. For 1/2" x 1" size see 1890 Catalog. 4. Also suitable for liquid service where ASME Code certification is not required. 2008 Farris Engineering

Capacity Tables: ASME PRESSURE VESSEL CODE (UV)


10% OVERPRESSURE

NON-CODE
25% OVERPRESSURE

AIR

Capacities in Standard Cubic Feet Per Minute at 60 F (Note 1)

Capacities in Pounds Per Hour at Saturation Temperature (Note 1)

10% OVERPRESSURE

STEAM

WATER

Capacities in U.S. Gallons Per Minute at 70 F

Set Pressure (psig) 15 20 30 40 50 60 70 80 90 100 150 200 250 300

3/4 x 1 1 x 1 1/2 1 1/2 x 2 93 108 136 168 199 231 263 294 326 357 515 673 830 988 160 185 234 288 342 396 450 504 558 612 882 1152 1423 1693 375 433 547 674 800 926 1053 1179 1305 1432 2063 2695 3327 3959

Set Pressure (psig) 15 20 30 40 50 60 70 80 90 100 150 200 250 300

3/4 x 1 1 x 1 1/2 1 1/2 x 2 263 303 384 473 561 650 738 827 916 1004 1448 1891 2334 2777 451 520 658 810 961 1113 1265 1417 1569 1720 2479 3238 3998 4757 1055 1216 1539 1894 2249 2604 2959 3313 3668 4023 5798 7573 9348 11122

Set Pressure (psig) 15 20 30 40 50 60 70 80 90 100 150 200 250 300

3/4 x 1 1 x 1 1/2 1 1/2 x 2 10.3 11.9 14.6 16.8 18.8 20.6 22.3 23.8 25.3 26.6 32.6 37.7 42.1 46.1 18.1 21.0 25.7 29.7 33.2 36.3 39.3 42.0 44.5 46.9 57.5 66.4 74.2 81.3 41.0 47.3 58.0 67.0 74.9 82.0 88.6 94.7 100 105 129 149 167 183

Notes: 1. Capacities for Air & Steam at 30 PSIG and below are based on 3 psi overpressure.

Actual Orifice Areas


Inlet Size 3/4" 1" 1 1/2" Vapor, Gas & Steam Liquid sq in sq mm sq in sq mm 0.240 155 0.109 70 0.411 265 0.192 124 0.961 620 0.433 279

Note: For sizing purposes, the coefficients of discharge Kd are 0.652 for air, gas, vapor and steam; 0.576 for liquids

Dimensions & Weights


Inlet Size 3/4 x 1 1 x 1 1/2 1 1/2 x 2 A (max) All Cap Constructions in. mm. 8 9 1/16 11 15/16 203 112 252 B in. 1 11/16 1 15/16 2 7/8 mm. 43 29 73 in. 2 5/8 3 3 11/16 C mm. 67 76 94 Approx. Weight Lbs. 3.5 5 11 Kg. 1.6 2.3 5.0

Farris Engineering

Division of Curtiss-Wright Flow Control Corporation

10195 Brecksville Road, Brecksville, OH 44141 USA Telephone: 440-838-7690 Fax: 440-838-7699 www.farrisengineering.com Facilities: Brecksville, OH USA; Brantford, Ontario; Edmonton, Alberta, Canada; Kettering, Northants, UK; Delhi, India; Tianjin, China Offices: worldwide. For a listing of our global sales network, visit our website at www.farrisengineering.com.
While this information is presented in good faith and believed to be accurate, Farris Engineering, Division of Curtiss-Wright Flow Control Corporation, does not guarantee satisfactory results from reliance on such information. Nothing contained herein is to be construed as a warranty or guarantee, expressed or implied, regarding the performance, merchantability, fitness or any other matter with respect to the products, nor as a recommendation to use any product or process in conflict with any patent. Farris Engineering, Division of Curtiss-Wright Flow Control Corporation, reserves the right, without notice, to alter or improve the designs or specifications of the products described herein.
Printed in USA 06/08-3M-R5