You are on page 1of 2

Product Data Sheet

RM17TA00
3 PHASE RELAY 250V 5AMP RM17
List Price $177.00 USD

Availability Stock Item: This item is normally stocked in our distribution facility.

Technical Characteristics
Permissible Relative Humidity Vibration Resistance - Operational Shock Resistance Degree of Protection Wiring range: Solid Cable without Cable End Application Function Supply Voltage Voltage Limits Adjustment of Voltage Threshold Frequency of Measured Signal Current Rating Contact Type Electrical Life (UL508) Operations at Rated Current (Resistive) Contact Configuration Frequency Hysteresis Output Type Operating Range Maximum Breaking Current Insulation Test Voltage: Dielectric Test Insulation Test Voltage: Shock Wave Maximum Measuring Cycle Measurement Range Phase-Phase Voltage Selection Setting Accuracy Utilization Categories Delay on Pick-up Time Delay on Crossing The Threshold Tt Ambient Air Temperature around the Device - Operation Ambient Air Temperature around the Device - Storage Wiring Range: Flexible Cable with Cable End 2 x 24 hrs. to +95% RH at +131 8F (55 8C) without condensation 0.035 mm from 10 to 150 Hz 5 IP30 (Casing) - IP20 (Terminal Block) Two: 16 to 20 AWG (1.5 to 0.5 mm2) - One: 14 to 20 AWG (2.5 to 0.5 mm2) Control of 3-phase supplies Asymmetry - Phase failure - Phase sequence 208 to 480 VAC -15% to +10% 2 to 20 % of Un selected 50 to 60 Hz 10% 5 A (1 A at 24 VDC, 5 A at 24 VAC, 3 A at 250 VAC) Cadmium-free 10,000 operations SPDT 50/60 Hz 10% 2% of Un, Fixed 1904-01-01 05:00:00 183 to 528 VAC 5 VAC/VDC 2 kV at 50 Hz for 1 min. on VAC 4 kV 150 ms per measurement as true rms value 183 to 528 VAC 208V - 380V - 220V - 440V - 415 - 480V - 400V 10% of the full scale value AC-12 - AC-13 - AC-14 - DC-13 - AC-15 - DC-12 500 ms 0.1 to 10 sec, 0 + 10% -20 to 50 -40 to 70 Two: 16 to 20 AWG (1.5 to 0.5 mm2) - One: 14 to 20 AWG (2.5 to 0.5 mm2)

Generated: 02/27/2013 12:42:51

2013 Schneider Electric. All rights reserved.

Tightening Torque Type Indication (LED) Mounting Style Weight Approvals Mechanical Life Unpowered Maximum Switching Requirement Minimum Breaking Current Maximum Consumption AC Maximum Consumption DC

0.6 to 1 N.m / 5.3 to 8.8 lb-in 17.5mm width 2 Din Rail 79.799999999999997 EMC - NF - EN - UL - CSA - CE - RoHS - IEC - GOST - GL - C-Tick 30,000,000 operations 250 VAC/VDC 10 V at 5 VDC 1.8 0

Shipping and Ordering


Category Discount Schedule GTIN Package Quantity Weight Availability Code Returnability Country of Origin 22380 CP2 00785901838890 1 0.19 lbs. Stock Item: This item is normally stocked in our distribution facility. Y ID

As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.

Generated: 02/27/2013 12:42:51

2013 Schneider Electric. All rights reserved.

You might also like