You are on page 1of 192

energy for a better world

PRODUCT CATALOGUE 2010

Foreword
TRITEC means clean energy. The cleanest energy comes from the sun: today and in the future. Energy for a better world is our motto. This guiding theme includes not only the environmental aspect, but it also and simultaneously places an important social demand on the global energy supply. For more than 20 years, TRITEC has been an international photovoltaic system supplier and centre of competence in the area of renewable energies. All components of a photovoltaic system, be it intended for grid connection or for stand-alone systems (page 6 et seqq.), must be perfectly coordinated, in order to achieve optimal efficiency. As your solar specialist and partner, we will advise and support you in planning your solar systems. You will find everything regarding technical advice, product software, documentation and training in the chapter Customer Support and Services. In addition to the perfect coordination of the individual PV components, the quality of each individual product is essential. After all, systems generating solar energy are exposed to the hardest weather conditions for many years. For this reason we only use A-brands as we only work with manufacturers guaranteeing the highest quality. You can find our products and photovoltaic system components on page 12 et seqq. TRITEC is also a system integrator and manufacturer of own brand products. During the planning and installation of small and medium-sized photovoltaic systems we work with qualified partner companies. As international system integrator we implement large photovoltaic systems and test state-of-the-art installation technologies, which will then be established in practical use. You will find some examples of our application areas in the chapter Reference Cases. As solar component manufacturer we are active in the mounting system and measuring technology. Our own brand products include the mounting systems TRI-STAND and TRI-VENT (see chapter Mounting Systems) as well as PV control and measuring instruments, such as the characteristics analyser TRI-KA II, newly enhanced for the Intersolar 2010 (see chapter Control and Measuring Instruments). The characteristics analyser TRI-KA II for checking the output of installed solar modules is available as an even more manageable and powerful model from the Intersolar 2010: The most important innovations of the TRI-KA are increased input range for current and voltage, two reference cells at the irradiation sensor, improved menu navigation with user-friendly touch screen and a new evaluation software. Do you have any questions about our new characteristics analyser TRI-KA II? Let us advise you or attend one of our TRI-KA product training courses. Give us a call: International Headquarters, Switzerland +41 61 699 35 55. Our catalogue is continuously updated; please also visit our web site: www.tritec-energy.com/products

Solar Power Plant 11.6 kWp, Jungfraujoch (Switzerland) In co-operation with TRITEC

Contents
PHOTOVOLTAICS
Introduction Grid-connected Systems Stand-alone Systems 6 8 10

PRODUCTS
Solar Modules Grid-connected Inverters Batteries Controllers Stand-alone Inverters Control and Measuring Instruments Mounting Systems Accessories Complete Systems 13-39 41-73 75-79 81-95 97-105 107-119 121-135 137-161 163-167

CUSTOMER SUPPORT AND SERVICES


Product Software Training Courses / Product Documentations 170 172

COMPANY
Reference Cases General Terms and Conditions TRITEC Contacts Imprint 175-187 188 190 191

Introduction to Photovoltaics
History of Photovoltaics
Photovoltaics are an essential part of the portfolio of renewable energies. At the EU level, the passing of the Directive for Renewable Energies set a mandatory target: By 2020, 20 per cent of the energy demand must be supplied by renewable energies. Feed-in tariffs and subsidies have resulted in a boom in the construction of photovoltaic installations worldwide. Already in 2004, the threshold of 1 GWp of installed electric rated power of photovoltaic installations was exceeded, which corresponded to an increase by a factor of more than 24 during the last ten years. And the newly installed photovoltaic output continues to grow every year. For the period of 2007 2012, an average annual growth of 48 per cent is expected. For the current year, the experts anticipate a newly installed output of 4776 MW. Already in 1839, the French physicist Alexandre Edmond Becquerel had discovered the photoelectric effect. But it took more than 100 years, until the first technical application in satellite technology could be realised at the end of the 50s. Driven by the energy crises of the 70s and supported by an increased environmental awareness, photovoltaics began to move towards economic efficiency 20 years later. In a few years, these efforts will result in the so-called grid parity the point when power generation using photovoltaics will be equal in costs to conventional power. In Germany, grid parity is expected to be reached in 2012.

Potential of Photovoltaics
The amount of sun energy impacting the earth as light and warmth is 1.5 1018 kWh per annum; this corresponds approximately to the 15000-fold of the entire primary energy consumption of humanity in 2006 (1.0 1014 kWh/year). This irradiation energy can be captured by the photovoltaic effect and partially converted to electricity, without the generation of undesirable by-products such as emissions (e.g. CO2) or nuclear waste. Central Europe on average can assume an annually irradiated output of 1000 kWh/m2, Southern Europe achieves values of 1700 kWh/m2, some desert regions even more than 2300 kWh/m2. If Central Europe wanted to cover the worlds power needs with the irradiated solar energy, an area of 400 by 400 kilometres would be required.

2 800 2 600 2 400 2 200 2 000 1 800 1 600 1 400 1 200 1 000 800 600 400 200 0

MWp/a

1992

1994

1994

1998

2000

2002

2004

2006

2008

Year

Global market volume for photovoltaics systems


Solarpraxis

5 750 MWp

Global annual solar irradiation in kWh/m


meteonorm

Stade de Suisse 1.35 MWp, Bern (Switzerland) Designed and installed by TRITEC

The Functional Principle of the Solar Cell


Todays solar cells mostly consist of the base material silicon, that is divided into two layers (p and n layer) with different electric properties by doping with boron or phosphorus and thus becomes a diode. In contrast to the conventional semiconductor diode found in electronic circuits and rectifiers, the solar cell is optimised to exploit incident sun light. For this purpose solar cells are manufactured with as large a surface as possible. The so-called p-n junction here is only just below the surface exposed to the solar irradiation. At the p-n junction an electric field is building that has a pull effect on free (mobile in the material) charge carriers. The photons (light energy packages) of the incident sun light penetrate the cell material and now produce free charge carriers (electrons and holes) in proximity to the p-n junction. These are separated from the inner field and swept to the electric connecting contacts on the top and bottom side of the cell. There they are available for use in an external circuit. Each cell has a usable voltage of 0.5 to 0.6 Volt, which can be increased to any value by connecting several cells in series. In solar modules the cells are partially connected in series and parallel, in order to achieve the optimum usable operating voltages. The production rate of the free charge carriers increases in proportion to the intensity of the solar irradiation. The photons energy is converted to electric power to the amount of approx. 15 % corresponding to the cells efficiency. The rest heats the solar cell and is discharged to the environment by means of heat transport processes. At standard test conditions (STC: 1000 W/m2, temperature 25 C, AirMass 1.5) up to 2.5 Ampere solar power and therefore approx. 1.5 W electric peak capacity can be expected per dm2 of cell surface. Due to their energy and material efficiency and therefore due to their lower costs, thin-film technologies show the greatest potential in the long term. Currently three different technologies are on the market: the amorphous/microcrystalline silicon technology, the CdTe based technology and the copper indium selenide (CIS) technology. Though these technologies are still in their infancy, manufacturers are working flat out on their development.

By means of special diagrams, the solar irradiation can be calculated depending on the mounting angle and the orientation. In Central Europe the solar irradiation is greatest at an orientation to the South and an angle of 30. A system with orientation to the South-West and a mounting angle of 30 for example, would achieve an annual solar irradiation of approx. 95 % of the maximum. In order to enable photovoltaic installations to achieve high yields, detailed planning is necessary. On the one hand the used components must be adapted perfectly to the individual requirements, and on the other attention must be given to correct dimensioning and placement with the least possible clouding. In addition, solar modules are daily exposed to wind and weather and must work faultlessly in spite of all adversities. Therefore, high-quality and durable products are another important prerequisite for good yields of photovoltaic systems.

Grid-connected Photovoltaic Systems


Design of Grid-connected Photovoltaic Installations
Grid-connected systems are photovoltaic installations that are connected to the public grid and feed the entire electric power generated by the solar energy to the grid. The size of a grid-connected system depends on different factors: roof/facade surface, financial resources and statutory provisions. Most European private grid-connected systems have an output of two to ten kilowatt. If an installation on a pitched roof is supposed to achieve such a yield, the required roof surface for two kilowatt (PV) is approximately 18 m2 and approximately 90 m2 for ten kilowatt. The essential components of grid-connected PV installation are photovoltaic modules, inverters, a mounting system, a protective device to automatically switch off in case of mains malfunctions and a meter to record the amount of power supplied. Two factors are essential for a high-yield system: 1. The quality of the installed products, incl. accessories (e.g. wiring); 2. The different components must be optimally coordinated. For 23 years now, TRITEC has been a photovoltaic system provider with a wide and premium range of quality products. Be it a stand-alone system for a remote mountain church in the Bndner Alps or a large system on the roof of a department store in Spain we are happy to support you in the planning as well as in case of queries regarding the approval and financing of photovoltaic installations.

Yield of a Photovoltaic Installation


The yield generated by a photovoltaic installation during a year is also called solar yield. A significant factor for the yield assessment of photovoltaic installations is the performance ratio. For this the yield of the photovoltaic installation is divided by the installed photovoltaic output and the annual irradiation. A performance ratio of more than 80 % indicates a good ratio of yield and irradiated solar output. Among the factors affecting the yield are the location of the photovoltaic installation, the orientation and the climate or the intensity and length of the solar irradiation.

Functional principle of a crystalline solar cell

Solarpraxis

Annual irradiation (%)

DGS / Solarpraxis

3 1 2

7 6 5
Solarpraxis

1. PV array 2. Mounting system 3. Wiring 4. PV array combiner/junction box 5. Grid-connected inverter 6. Import/export meter 7. Connection to grid 8. Consumer loads

Principle of a grid-connected photovoltaic system

Stand-alone Systems Independent Photovoltaic Installations


Photovoltaic installations, operated independently from the mains supply, are also called stand-alone systems. The power generated by means of solar modules is stored in batteries or can be supplied directly to consumers. This solution is chosen for remote locations (weekend houses, Alpine huts, farm houses etc.), where a connection to the mains supply does not make economic sense due to the cost of new cables (e.g. street lighting, emergency telephones etc.) or is simply impossible (caravans, marine, remote places). The correct dimensioning of a stand-alone power installation is essential. Correct in this context does not mean oversized; the aim is the optimal combination of technical expedience and affordability. The following four questions help in determining the correct size of a system: How much power is used in what time? How many and which consumers must be supplied, and how great is the energy consumption at which time? What is the consumers rated voltage? Is it necessary to use a stand-alone inverter for 230 or 120 V or can new consumers with 12 or 24 V be used? How long are the consumers supposed to be able to operate with insufficient sunlight (autonomous time)? Determination of the number and size of the batteries. How long are the batteries supposed to take to fully recharge? This determines the number and capacity of the solar modules. A list of all consumers provides information on the power consumption to be expected. When combined with the calculated daily time of use, the daily required power demand can be determined in watt-hours (Wh) or in ampere-hours (Ah). For direct operation (pumps, fans, electric motors etc.) output and operating voltage of the module must correspond with the connected load and operating voltage of the consumer. Therefore, a 54 watt solar module would be sufficient for a 50 watt consumer. If the consumer however needs to be operated even with insufficient solar irradiation, the modules output must be increased correspondingly. At the same time it is important to avoid an overload of the consumer through excessively high voltage in case of strong solar irradiation.
Principle of a stand-alone photovoltaic system
Solarpraxis

Stand-alone systems require special devices and lights. In addition to special solar modules, these include standalone inverters and accumulators/batteries, which can process great and small charge currents to a high level of efficiency, a charge controller, which in turn protects the battery against overloading. Additionally, a load control protects against total discharge. TRITEC supplies quality products that are especially suitable for stand-alone systems, and has many years of know-how in the design of such systems.

11

Ziteil Pilgrimage Church 1.7 kWp, Salouf GR (Switzerland) Designed and installed by TRITEC

Solar Modules
We offer solar modules of the latest generation: for gridintegrated equipment, stand-alone solutions, emergency power supply, pumping systems, solar power plants, telecommunication or trafc signals.

KYOCERA SANYO SCHOTT SOLAR SOLARWORLD SUNTECH


13

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

The KD series Large-area photovoltaic modules with new frame


Advanced technology
Thanks to Kyocera's advanced cell processing technology, intensive research and automated production facilities they are able to produce a highly efcient polycrystalline photovoltaic module. ease of mounting, which now has a height of 46 mm and can tolerate stresses of up to 5400 N/m. The connecting box on the back is provided with bypass diodes preventing the risk of overheating of individual solar cells (hot spot effect). Several PV modules connected in series can easily be wired up using pre-assembled solar cables and MultiContact plugs. Kyocera manufactures all components in its own manufacturing plants without the acquisition of semi nished products for a constantly high quality of its products.

14

The embedded Kyocera high-performance solar cells with the basic measurement 156 x 156 mm achieve an efciency of over 16 % and guarantee an extremely high annual energy output of the photovoltaic plant.

High efciency

Improved aluminium frame

These cells are encapsulated between a tempered glass cover (resistance to impact of hail acc. to IEC 61215 ed. 2 tested by the TV Technical Control Association) and an EVA pottant with back sheet to provide efcient protection from the severest environmental conditions. The entire laminate is installed in an anodized aluminum frame to provide structural strength and

Range of application
n n n n n

Private residences Industrial and large plants Agricultural operations Free-standing plants Solar energy plants

The new KD series from Kyocera with increased efciency and performance.

The KD series has new dimensions and thus is incompatible with previous models of the KC series.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101118

0101119

0101138

0101121

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current NOCT Reverse current load Max. string protection Cells per module Cell dimensions (L / W) Cell connection Connection Mounting frame Dimensions (L / W / H) Lengths (a / b / c / d) Weight Max. load Performance warranty * Product warranty Norms

KD135GH-2PU 135 W 5 % 1000 V 17.7 V 7.63 A 22.1 V 8.37 A -0.80 x 10 V/C 5.02 x 10 A/C 47.9 C 15 A 15 A 36 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 840 (-) / 840 (+) mm Black anodized aluminium 1500 mm / 668 mm / 46 mm 471.5 mm / 278.5 mm / 12.5 mm / 643 mm 12.5 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299 0101209

KD180GH-2PU 180 W 5 % 1000 V 23.6 V 7.63 A 29.5 V 8.35 A -1.06 x 10 V/C 5.01 x 10 A/C 47.9 C 15 A 15 A 48 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 670 (-) / 870 (+) mm Black anodized aluminium 1338 mm / 990 mm / 46 mm 412.5 mm / 256.5 mm / 12.5 mm / 965 mm 16.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299 0101210

KD185GH-2PU 185 W 5 % 1000 V 23.6 V 7.84 A 29.5 V 8.58 A -1.06 x 10 V/C 5.15 x 10 A/C 47.9 C 15 A 15 A 48 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 670 (-) / 870 (+) mm Black anodized aluminium 1338 mm / 990 mm / 46 mm 412.5 mm / 256.2 mm / 12.5 mm / 965 mm 16.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299 0101211

KD210GH-2PU 210 W 5 % 1000 V 26.6 V 7.90 A 33.2 V 8.58 A -1.20 x 10 V/C 5.15 x 10 A/C 47.9 C 15 A 15 A 54 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 750 (-) / 950 (+) mm Black anodized aluminium 1500 mm / 990 mm / 46 mm 471.5 mm / 278.5 mm / 12.5 mm / 965 mm 18.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299

15

Art. No.

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current NOCT Reverse current load Max. string protection Cells per module Cell dimensions (L / W) Cell connection Connection Mounting frame Dimensions (L / W / H) Lengths (a / b / c / d) Weight Max. load Performance warranty * Product warranty Norms

KD215GH-2PU 215 W +5 %, -3 % 1000 V 26.6 V 8.09 A 33.2 V 8.78 A -1.20 x 10 V/C 5.27 x 10 A/C 47.9 C 15 A 15 A 54 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 750 (-) / 950 (+) mm Black anodized aluminium 1500 mm / 990 mm / 46 mm 471.5 mm / 278.5 mm / 12.5 mm / 965 mm 18.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299

KD230GH-2PB 230 W +5 %, -3 % 1000 V 29.8 V 7.72 A 36.9 V 8.36 A -1.33 x 10 V/C 5.02 x 10 A/C 47.9 C 15 A 15 A 60 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 830 (-) / 1030 (+) mm Black anodized aluminium 1662 mm / 990 mm / 46 mm 1100.0 mm / 550.0 mm / 12.5 mm / 965 mm 21.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299

KD235GH-2PB 235 W +5 %, -3 % 1000 V 29.8 V 7.89 A 36.9 V 8.55 A -1.33 x 10 V/C 5.13 x 10 A/C 47.9 C 15 A 15 A 60 pc. 156 mm / 156 mm 3 bus bar MC PV-KBT3 / MC PV-KST3, cables, 830 (-) / 1030 (+) mm Black anodized aluminium 1662 mm / 990 mm / 46 mm 1100.0 mm / 550.0 mm / 12.5 mm / 965 mm 21.0 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023299

* - Manufacturer's performance warranty: 10 years on 90 % / 20 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

The KD series Versatile cutting-edge technology for stand-alone systems


Advanced technology
Thanks to Kyocera's advanced cell processing technology, intensive research and automated production facilities they are able to produce a highly efcient polycrystalline photovoltaic module. feature an accessible connecting box. The solar cables can therefore be mounted exibly, which makes installations of stand-alone systems signicantly easier again. Kyocera grants a 20 years performance warranty for KD models according to the warranty conditions.

16

6" cells

The new cell generation of the Kyocera high-performance solar cells has been introduced a short while ago with the bigger Kyocera modules. Now the smaller panels of the KD series are also equipped with this cell. The almost black cell has three cell connectors and achieves a very high efciency. This guarantees an extremely high annual energy output of the photovoltaic plant.

Range of application
n

n n

Flexible connecting box

Stand-alone solar power systems for villages in remote areas, homes and summer cottages, radio repeater stations or medical facilities in rural areas Emergency power systems and disaster control Pumping systems (e.g. for drinking water supply in remote areas and irrigation) Telecommunication

All KD modules suitable for non-grid-connected power supply (module types with -1P designation) now again

The new KD series from back to front: KD135SX-1PU, KD95SX-1P, KD70SX-1P and KD50SE-1P.

The accessible connecting box for the individual connection does not have pre-assembled cables.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101122

0101123

0101125

0101126

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Connection Mounting frame Dimensions (L / W / H) * Mounting holes (a / b / c) Weight Max. load Performance warranty ** Product warranty Norms

KD50SE-1P 50 W +10 %, -5 % 750 V 17.9 V 2.80 A 22.1 V 3.07 A Screw terminals Silvery anodized aluminium 706 mm / 744 mm / 36 mm 112.0 mm / 324.0 mm / 29.0 mm 6.5 kg 2400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023574

KD70SX-1P 70 W +10 %, -5 % 750 V 17.9 V 3.92 A 22.1 V 4.30 A Screw terminals Silvery anodized aluminium 778 mm / 660 mm / 36 mm 148.0 mm / 360.0 mm / 29.0 mm 6.5 kg 2400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023574

KD95SX-1P 95 W +10 %, -5 % 750 V 17.9 V 5.31 A 22.1 V 5.81 A Screw terminals Silvery anodized aluminium 1043 mm / 660 mm / 36 mm 280.5 mm / 492.5 mm / 29.0 mm 8.5 kg 2400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023574

KD135SX-1PU 135 W 5 % 750 V 17.7 V 7.63 A 22.1 V 8.37 A Screw terminals Black anodized aluminium 1500 mm / 668 mm / 46 mm 471.5 mm / 278.5 mm / 12.5 mm 12.5 kg 5400 N/m 10 / 20 years 5 years IEC 61215 ed. 2, IEC 61730, protection class II, TVdotCOM-ID: 0000023574

17

* - The connection box at the back of each module protrudes the aluminium frame. At this point the module has a height of 45 mm. ** - Manufacturer's performance warranty: 10 years on 90 % / 20 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

The KD135SX-1PU is already available with the new 46 mm frame; all other stand-alone modules of the KD series continue to be based on the 36 mm frame.

The dimensions and the mounting holes.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Sanyo HIP series Modules with powerful HIT solar cells


HIT solar cells
All modules of the Sanyo HIP series are equipped with the new HIT solar cell technology. The Sanyo HIT solar cell (Heterojunction with Intrinsic Thin layer) consists of monocrystalline hybrid wafers coated with thin amorphous silicon. The modern manufacturing process allows for the manufacture of solar cells with the highest levels of efciency and optimum energy yields. cells convince with their high energy yield, even at high temperatures.

Environmentally friendly

18

Annually, HIT solar cells can yield more output per surface than conventional crystalline solar cells. Due to the small dimensions, maximum output can be achieved even on small surfaces.

High efciency

In commercial solar products worldwide, HIT solar cells achieve one of the highest efciencies. Compared to conventional solar cells with crystalline silicon, the HIT

Advantages in brief
n n n n

Highest level of efciency Maximum energy yields More output per surface Small dimensions

The modules of the Sanyo HIP-NKHE series are based on hybrid HIT solar cells (amorphous and monocrystalline silicon) with the highest levels of efciency.

The series Sanyo HIP-HDE employs HD-HIT solar cells, which optimally exploit the raw material silicon, due to their geometric design.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101149

0101160

0101150

0101158

0101159

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Cells per module Cell type Cell dimensions Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Sanyo HIP-210NKHE5 210 W +10 %, -5 % 1000 V DC 41.3 V 5.09 A 50.9 V 5.57 A -0.30 %/C -127 mV/C 1.67 mA/C 72 pc. HIT solar cell, monocrystalline 125 / 125 mm MC3 connectors, cable 960 mm each (+ / ) Anodized aluminium 1580 mm 2 mm / 798 mm 2 mm / 35 mm 1 mm 15.0 kg (approx.) 2400 N/m 10 / 20 years 5 years IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOM-ID: 0000022408

Sanyo HIP-214NKHE5 214 W +10 %, -5 % 1000 V DC 41.9 V 5.12 A 51.5 V 5.60 A -0.30 %/C -129 mV/C 1.68 mA/C 72 pc. HIT solar cell, monocrystalline 125 / 125 mm MC3 connectors, cable 960 mm each (+ / ) Anodized aluminium 1580 mm 2 mm / 798 mm 2 mm / 35 mm 1 mm 15.0 kg (approx.) 2400 N/m 10 / 20 years 5 years IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOM-ID: 0000022408

Sanyo HIP-215NKHE5 215 W +10 %, -5 % 1000 V DC 42.0 V 5.13 A 51.6 V 5.61 A -0.30 %/C -129 mV/C 1.68 mA/C 72 pc. HIT solar cell, monocrystalline 125 / 125 mm MC3 connectors, cable 960 mm each (+ / ) Anodized aluminium 1580 mm 2 mm / 798 mm 2 mm / 35 mm 1 mm 15.0 kg (approx.) 2400 N/m 10 / 20 years 5 years IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOM-ID: 0000022408

Sanyo HIT-235HDE4 235 W +10 %, -5 % 1000 V DC 35.1 V 6.70 A 43.4 V 7.33 A -0.30 %/C -109 mV/C 2.20 mA/C 60 pc. HIT solar cell, monocrystalline 166 mm MC3 connectors, cable 1150 mm each (+ / ) Anodized aluminium 1610 mm 2 mm / 861 mm 2 mm / 35 mm 1 mm 16.5 kg (approx.) 2400 N/m 10 / 20 years 5 years IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOM-ID: 0000022202

Sanyo HIT-240HDE4 240 W +10 %, -5 % 1000 V DC 35.5 V 6.77 A 43.6 V 7.37 A -0.30 %/C -109 mV/C 2.21 mA/C 60 pc. HIT solar cell, monocrystalline 166 mm MC3 connectors, cable 1150 mm each (+ / ) Anodized aluminium 1610 mm 2 mm / 861 mm 2 mm / 35 mm 1 mm 16.5 kg (approx.) 2400 N/m 10 / 20 years 5 years IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOM-ID: 0000022202

19

* - Manufacturer's performance warranty: 10 years on 90 % / 20 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

At very high module temperatures the HIT solar cells generate clearly higher outputs, compared to monocrystalline cells.

The special HD (Honeycomb Design) HIT solar cells require less silicon per Wp, which reduces the amortisation period.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Schott ASI Series The next generation


Schott ASI technology More energy

20

Schott ASI thin-lm solar modules guarantee an above average high performance and energy yield. More energy, the robust encapsulation, the quick and easy installation and the top safety all these are features contributing to the top quality of the ASI modules.

The proven Schott ASI modules stand for high, stable performance and longevity. Independent surveys have shown that under real operation conditions such as clouded skies or high ambient temperatures the modules deliver extremely high energy yields.

Proven and tested quality

Only the highest quality of the individual components can achieve the highest energy yields. The modules are designed from frame to junction box for cost-effective and high-quality system integration. Schott modules have been awarded top ratings in a number of independent studies and surveys.

Easy installation

Installation of Schott ASI modules can be extremely quick and easy. This is not least due to the anodised aluminium frame and the pre-installed cables with Tyco connectors. The by-pass diodes of the modules are already integrated into the electrical connection boxes at the rear of the modules.

The modules of the Schott ASI series are based on amorphous thin-lm silicon.

The Schott ASI thin-lm modules are suited for building fronts and roofs that are not optimally oriented.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101130

0101111

0101112

0101132

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cell type Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Schott ASI 87 87 W 5 % 1000 V DC 17.2 V 10 % 5.07 A 10 % 23.3 V 10 % 6.50 A 10 % -0.20 %/C -0.31 %/C 0.08 %/C -40 to +85 C a-Si (amorphous silicon) Tyco-Connectors, cable 1.2 m each (+ / ) Anodized aluminium 1108 mm 3 mm / 1308 mm 3 mm / 50 mm 1 mm 18 kg (approx.) 2400 N/m 10 / 25 years 5 years IEC 61730, IEC 61646, EWG guideline 89/392 (CE)

Schott ASI 90 90 W 5 % 1000 V DC 17.3 V 10 % 5.21 A 10 % 23.4 V 10 % 6.60 A 10 % -0.20 %/C -0.31 %/C 0.08 %/C -40 to +85 C a-Si (amorphous silicon) Tyco-Connectors, cable 1.2 m each (+ / ) Anodized aluminium 1108 mm 3 mm / 1308 mm 3 mm / 50 mm 1 mm 18 kg (approx.) 2400 N/m 10 / 25 years 5 years IEC 61730, IEC 61646, EWG guideline 89/392 (CE)

Schott ASI 95 95 W 5 % 1000 V DC 17.4 V 10 % 5.47 A 10 % 23.6 V 10 % 6.69 A 10 % -0.20 %/C -0.31 %/C 0.08 %/C -40 to +85 C a-Si (amorphous silicon) Tyco-Connectors, cable 1.2 m each (+ / ) Anodized aluminium 1108 mm 3 mm / 1308 mm 3 mm / 50 mm 1 mm 18 kg (approx.) 2400 N/m 10 / 25 years 5 years IEC 61730, IEC 61646, EWG guideline 89/392 (CE)

Schott ASI 100 100 W 5 % 1000 V DC 17.5 V 10 % 5.71 A 10 % 23.8 V 10 % 6.79 A 10 % -0.20 %/C -0.31 %/C 0.08 %/C -40 to +85 C a-Si (amorphous silicon) Tyco-Connectors, cable 1.2 m each (+ / ) Anodized aluminium 1108 mm 3 mm / 1308 mm 3 mm / 50 mm 1 mm 18 kg (approx.) 2400 N/m 10 / 25 years 5 years IEC 61730, IEC 61646, EWG guideline 89/392 (CE)

21

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Photos Schott Solar AG

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Schott Poly 5" Series The Allrounders


Maximum energy Quick and easy installation

22

The high performance modules Schott Poly 165/170/175/180 are made of high-quality crystalline solar cells. The special Schott Solar cell technology, using multicrystalline wafers, ensures optimum output and efciency. The innovative isotexturing of the cells allows the module's performance to be increased further; additionally it provides a homogeneous appearance of the dark-blue cells. These modules have been awarded top ratings in a number of independent studies and surveys.

The anodized aluminum frame and the preinstalled cable with Tyco-Connectors ensure quick and easy installation. Schott modules are designed from frame to connection box for cost-effective system integration.

System voltage up to 1000 V

The Safety Class II module is congured for system voltage of up to 1000 V. It is suitable for grid-connected systems.

Narrow output tolerance

A very narrow module output selection permits serial connection with low connection losses.

Due to advanced manufacturing, the Schott modules achieve a maximum energy yield.

Current/voltage characteristics with dependence on irradiance and module-temperature.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101034

0101037

0101042

0101107

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Schott Poly 165 165 W 4 % 1000 V DC 35.1 V 10 % 4.70 A 10 % 43.6 V 10 % 5.27 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 72 pc. MAIN solar cell, multicrystalline, isotextured 125 mm / 125 mm Tyco-Connectors, cable 1 m each (+ / ) Anodized aluminium 1620 mm 3 mm / 810 mm 3 mm / 50 mm 1 mm 15.5 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 170 170 W 4 % 1000 V DC 35.5 V 10 % 4.78 A 10 % 44.0 V 10 % 5.30 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 72 pc. MAIN solar cell, multicrystalline, isotextured 125 mm / 125 mm Tyco-Connectors, cable 1 m each (+ / ) Anodized aluminium 1620 mm 3 mm / 810 mm 3 mm / 50 mm 1 mm 15.5 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 175 175 W 4 % 1000 V DC 35.9 V 10 % 4.87 A 10 % 44.3 V 10 % 5.34 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 72 pc. MAIN solar cell, multicrystalline, isotextured 125 mm / 125 mm Tyco-Connectors, cable 1 m each (+ / ) Anodized aluminium 1620 mm 3 mm / 810 mm 3 mm / 50 mm 1 mm 15.5 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 180 180 W 4 % 1000 V DC 36.3 V 10 % 4.95 A 10 % 44.6 V 10 % 5.39 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 72 pc. MAIN solar cell, multicrystalline, isotextured 125 mm / 125 mm Tyco-Connectors, cable 1 m each (+ / ) Anodized aluminium 1620 mm 3 mm / 810 mm 3 mm / 50 mm 1 mm 15.5 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

23

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Photos Schott Solar AG

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Schott Poly 6" Series The Top Performers


Maximum energy Narrow output tolerance

24

The new Schott Poly 210/217/220/225/230 series is manufactured from 6" cells, which generate signicantly more power due to the greater cell surface. The special Schott Solar cell technology, using multicrystalline wafers, ensures optimum output and efciency. The innovative isotexturing of the cells allows the module's performance to be increased further; additionally it provides a homogeneous appearance of the darkblue cells. These modules have been awarded top ratings in a number of independent studies and surveys.

The particularly close selection of module performance allows serial connection with small connection losses without complex sorting.

Simple installation and greatest stability

The anodized aluminum frame and the preinstalled cable with Tyco-Connectors ensure quick and easy installation. The framed Schott modules are designed for loads of up to 5400 N/m.

System voltage up to 1000 V

The Safety Class II module is congured for system voltage of up to 1000 V. It is suitable for grid-connected systems.

Schott Poly 210/217/220/225/230 convinces with particularly high nominal power; due to the 6 inch cells, the module surface is utilised optimally.

The close selection of module performance makes the Schott Poly 210/217/220/225/230 ideal for individual installations as well as for large-scale installations.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101117

0101113

0101154

0101114

0101155

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Schott Poly 210 210 W 4 % 1000 V DC 29.3 V 10 % 7.16 A 10 % 36.1 V 10 % 7.95 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 60 pc. MAIN solar cell, multicrystalline, isotextured 156 mm / 156 mm Tyco-Connectors, cable 1.1 m each (+ / ) Anodized aluminium 1685 mm 3 mm / 993 mm 3 mm / 50 mm 1 mm 23 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 217 217 W 4 % 1000 V DC 29.6 V 10 % 7.33 A 10 % 36.4 V 10 % 8.10 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 60 pc. MAIN solar cell, multicrystalline, isotextured 156 mm / 156 mm Tyco-Connectors, cable 1.1 m each (+ / ) Anodized aluminium 1685 mm 3 mm / 993 mm 3 mm / 50 mm 1 mm 23 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 220 220 W 4 % 1000 V DC 29.7 V 10 % 7.41 A 10 % 36.5 V 10 % 8.15 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 60 pc. MAIN solar cell, multicrystalline, isotextured 156 mm / 156 mm Tyco-Connectors, cable 1.1 m each (+ / ) Anodized aluminium 1685 mm 3 mm / 993 mm 3 mm / 50 mm 1 mm 23 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 225 225 W 4 % 1000 V DC 29.8 V 10 % 7.55 A 10 % 36.7 V 10 % 8.24 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 60 pc. MAIN solar cell, multicrystalline, isotextured 156 mm / 156 mm Tyco-Connectors, cable 1.1 m each (+ / ) Anodized aluminium 1685 mm 3 mm / 993 mm 3 mm / 50 mm 1 mm 23 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

Schott Poly 230 230 W 4 % 1000 V DC 30.0 V 10 % 7.66 A 10 % 36.9 V 10 % 8.33 A 10 % -0.47 %/C -0.38 %/C 0.10 %/C -40 to +85 C 60 pc. MAIN solar cell, multicrystalline, isotextured 156 mm / 156 mm Tyco-Connectors, cable 1.1 m each (+ / ) Anodized aluminium 1685 mm 3 mm / 993 mm 3 mm / 50 mm 1 mm 23 kg (approx.) 5400 N/m 10 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, EWG guideline 89/392 (CE)

25

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Photos Schott Solar AG

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Schott Poly Double Glass Extremely well built


More than 50 years of experience Best performance

26

For more than 50 years, Schott Solar is developing and producing solar modules and components for power generation. The new crystalline photovoltaic modules are characterised by their high yield performance and long life-cycle. The Schott Poly 280, 290 and 300 are tested under internal guidelines for a test time, which is twice the time demanded by the IEC standard. This guarantees optimum quality.

In order to allow serial wiring with the least wiring losses possible, only cells with particularly small output tolerances are used within the modules. The increased reverse current resistance minimises the wiring expenditure. All modules have only a positive tolerance of their nominal power rating, thus ensuring consistently high energy yields.

Optimum resilience

Advantages in brief
n n n n n n n

The use of double glass achieves a long module lifecycle. The anodised and cavity-free aluminium frame additionally warrants a high distortion resistance. The modules withstand surface and snow loads of up to 550 kg per square meter, which ensures a high degree of safety.

Long life-cycle through double glass Semi-transparent Double standard of quality High resilience Highest principle of specic performance Long-term reliability Increased reverse current resistance

582 grounding hole

approx. 105

9 (4x) grounding hole - symbol

The semi-transparent Schott Poly 280/290/300 are particularly suitable for high static demands, due to their double glass design.

The Schott Poly 280/290/300 are among the most powerful modules to be found on the market.

8103 4.25 (2x) 437.5 15.5 572.5 12813

16853 16
all dimensions in mm

26 13133

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101134

0101135

0101136

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Schott Poly 280 280 W 4 % 1000 V DC 39.1 V 10 % 7.16 A 10 % 48.1 V 10 % 7.95 A 10 % -0.47 %/C -161 mV/K 2.39 mA/K -40 to +85 C

Schott Poly 290 290 W 4 % 1000 V DC 39.5 V 10 % 7.33 A 10 % 48.5 V 10 % 8.10 A 10 % -0.47 %/C -162 mV/K 2.43 mA/K -40 to +85 C

Schott Poly 300 300 W 4 % 1000 V DC 39.7 V 10 % 7.55 A 10 % 48.9 V 10 % 8.24 A 10 % -0.47 %/C -163 mV/K 2.47 mA/K -40 to +85 C

27

80 pc. 80 pc. 80 pc. MAIN solar cell, multi-crystalline, MAIN solar cell, multi-crystalline, MAIN solar cell, multi-crystalline, isotextured isotextured isotextured 156 mm / 156 mm 156 mm / 156 mm 156 mm / 156 mm Tyco-Connectors, cable, 0.9 (-) / 2.1 (+) m Tyco-Connectors, cable, 0.9 (-) / 2.1 (+) m Tyco-Connectors, cable, 0.9 (-) / 2.1 (+) m Anodized aluminium Anodized aluminium Anodized aluminium 1685 mm 3 mm / 1313 mm 3 mm / 1685 mm 3 mm / 1313 mm 3 mm / 1685 mm 3 mm / 1313 mm 3 mm / 50 mm 1 mm 50 mm 1 mm 50 mm 1 mm 41.5 kg (approx.) 41.5 kg (approx.) 41.5 kg (approx.) 5400 N/m 5400 N/m 5400 N/m 10 / 30 years 10 / 30 years 10 / 30 years 5 years 5 years 5 years IEC 61730, IEC 61215 ed. 2, protection IEC 61730, IEC 61215 ed. 2, protection IEC 61730, IEC 61215 ed. 2, protection class II, CE mark class II, CE mark class II, CE mark

* - Manufacturer's performance warranty: 10 years on 90 % / 30 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Photos Schott Solar AG

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

SolarWorld Sunmodule+ Mono Featuring monocrystalline 6" cells


Innovation
With the series Sunmodule+ Mono, SolarWorld presents a new module concept for the performance categories 220 to 245 Wp. Without costly sorting on site, the Plus sorting ensures the highest levels of efciency and yield. The fully automated manufacture of the modules guarantees a constant high product quality and long-term high yields.

Quality

28

The patented connection box provides perfect protection against corrosion, as well as a capacity to rapidly dissipate any excess heat providing lower operating temperature. The connection box is reliably connected by a solid, welded bond to guarantee lasting functionality. The high-quality cables and connectors used ensure highest quality at all times.

The glass is set deep into the module frame and they are rmly attached to each other by silicone that is applied with continuous precision. This results in an excellent stability of the modules, which can bear loads of up to 5400 N/m on the front side. Thus the modules can withstand even great snow and wind loads.

Stability

Benets
n n n n n

Highest efciency due to Plus sorting No sorting on site Best stability Patented connection box Highest reliability

The fully automated manufacturing process of SolarWorld provides for high product quality and long-term high yields.

The new series SW mono black meets even architectural design demands with its black frame and black back foil.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101139

0101140

0101141

0101142

0101143

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current Reverse current load Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms Art. No.

Sunmodule+ SW 220 mono 220 W 3 % 1000 V 29.3 V 10 % 7.51 A 10 % 36.6 V 10 % 8.18 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark 0101144

Sunmodule+ SW 225 mono 225 W 3 % 1000 V 29.7 V 10 % 7.59 A 10 % 37.3 V 10 % 8.13 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark 0101188

Sunmodule+ SW 230 mono 230 W 3 % 1000 V 30.0 V 10 % 7.68 A 10 % 37.4 V 10 % 8.16 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark 0101189

Sunmodule+ SW 235 mono 235 W 3 % 1000 V 30.3 V 10 % 7.77 A 10 % 37.5 V 10 % 8.19 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark 0101190

Sunmodule+ SW 240 mono 240 W 3 % 1000 V 30.6 V 10 % 7.87 A 10 % 37.6 V 10 % 8.22 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark 0101191

29

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current Reverse current load Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Sunmodule+ SW 245 mono 245 W 3 % 1000 V 30.1 V 10 % 8.14 A 10 % 37.3 V 10 % 8.78 A 10 % -0.33 %/K 0.036 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark

Sunmodule+ SW 220 mono black 220 W 3 % 1000 V 29.4 V 10 % 7.50 A 10 % 37.2 V 10 % 8.10 A 10 % -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark

Sunmodule+ SW 225 mono black 225 W 3 % 1000 V 29.7 V 10 % 7.59 A 10 % 37.3 V 10 % 8.13 A 10 % -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark

Sunmodule+ SW 230 mono black 230 W 3 % 1000 V 30.0 V 10 % 7.68 A 10 % 37.4 V 10 % 8.16 A 10 % -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark

Sunmodule+ SW 235 mono black 235 W 3 % 1000 V 30.3 V 10 % 7.77 A 10 % 37.5 V 10 % 8.19 A 10 % -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. Monocrystalline silicon 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, CE mark

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and then a maximum output reduction of 0.7 % per year The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Minor reduction in efciency under partial load conditions at 25C: at 200 W/m, 95 % (3 %) of the STC efciency (1000 W/m) is achieved.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

SolarWorld Sunmodule+ Mono compact The innovative module concept


Greatest efciency
With the Plus sorting, SolarWorld AG presents an innovative and extremely efcient module concept, which eliminates time-consuming sorting of modules on site. The fully automated manufacture of the modules guarantees continuously high quality and long-term high yields.

Optimum reliability

30

The patented, at and compact connecting box guarantees optimum reliability even after many years. It protects against corrosion; in addition, the fast heat dissipation provides optimum temperature stability. The welded connections ensure a reliable electric connection inside the box.

Best stability

The module frame and the encased glass are rmly joined together using silicone, which ensures the greatest stability of the modules. This prevents the frame from becoming detached by sliding snow or other environmental inuences. The load capacity of the front is certied for up to 5400 N/m according to IEC 61215. Consequently, the module withstands the greatest snow loads and ice accumulations.

Advantages in brief
n n n

n n

Greatest efciency due to Plus sorting Best stability up to 5400 N/m Optimum reliability thanks to patented connecting box Recyclability of modules 25 years linear performance guarantee

682

31 M5

The Sunmodule+ Mono compact have a visually sophisticated design due to the black back foil and the black anodised frame.

1675

The new module frame of the Sunmodule+ Mono compact series has been optimised to 31 mm width and continues to guarantee stability up to 5400 N/m.

950

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101194

0101195

0101196

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current Reverse current load Cells per module Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Sunmodule+ SW 145 compact mono black 145 W 3 % 1000 V 19.4 V 7.50 A 24.7 V 8.10 A -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 40 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Black anodized aluminium 1675 mm / 682 mm / 31 mm 13 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215, protection class II

Sunmodule+ SW 150 compact mono black 150 W 3 % 1000 V 19.8 V 7.59 A 24.9 V 8.13 A -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 40 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Black anodized aluminium 1675 mm / 682 mm / 31 mm 13 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215, protection class II

Sunmodule+ SW 155 compact mono black 155 W 3 % 1000 V 20.2 V 7.68 A 25.0 V 8.16 A -0.33 %/K 0.042 %/K Don't apply external voltages in excess of Uoc to the module 40 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Black anodized aluminium 1675 mm / 682 mm / 31 mm 13 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215, protection class II

31

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and then a maximum output reduction of 0.7 % per year The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Minor reduction in efciency under partial load conditions at 25C: at 200 W/m, 95 % (3 %) of the STC efciency (1000 W/m) is achieved.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

SolarWorld Sunmodule+ Poly Featuring polycrystalline 6" cells


Top-quality products for every application
SolarWorld's state-of-the-art, fully automated production plants produce highest-quality Sunmodule Plus suitable for all applications in solar power technology from the rooftop to the large-scale plant.

High stability

32

Highest precision

The Sunmodule Plus by SolarWorld offers an innovative module concept. The Plus sorting guarantees higher efciency of the installation and spares the complex sorting on site. Additionally, the unique, fully automated production process ensures the highest level of precision and consistently high production quality. Also, the machine nishing produces a highly homogeneous design.

The polycrystalline 6" cells lie behind a 4 mm hardened-glass glazing and are embedded in transparent EVA (ethylene-vinyl-acetate). The back of the module is sealed with a very high quality Tedlar lm. The module stability is the result of the high depth at which the glass is inserted in the frame and adhering the frame using laminate.

High-quality and reliability

The at and compact connection box is mounted at the back of the module using a unique, patented process. It has no hollow spaces, is watertight, UV-, microbe as well as temperature resistant. This at and compact top-quality product is the ideal solution for every application.

The unique fully automated production process ensures the quality of the Sunmodule+.

Sunmodule+ are suitable for application in many elds.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101028

0101029

0101030

0101031

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current Reverse current load Cells per module Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms Art. No.

Sunmodule+ SW 205 poly 205 W 3 % 1000 V 28.5 V 7.20 A 36.2 V 7.80 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61215 ed. 2, protection class II 0101032

Sunmodule+ SW 210 poly 210 W 3 % 1000 V 28.7 V 7.32 A 36.4 V 7.90 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61215 ed. 2, protection class II 0101033

Sunmodule+ SW 215 poly 215 W 3 % 1000 V 28.9 V 7.44 A 36.5 V 8.00 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61215 ed. 2, protection class II 0101197

Sunmodule+ SW 220 poly 220 W 3 % 1000 V 29.2 V 7.54 A 36.6 V 8.08 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61215 ed. 2, protection class II 0101198

33

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current Reverse current load Cells per module Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Sunmodule+ SW 225 poly 225 W 3 % 1000 V 29.5 V 7.63 A 36.8 V 8.17 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II

Sunmodule+ SW 230 poly 230 W 3 % 1000 V 29.8 V 7.72 A 36.9 V 8.25 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II

Sunmodule+ SW 235 poly 235 W 3 % 1000 V 30.0 V 7.85 A 37.0 V 8.35 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II

Sunmodule+ SW 240 poly 240 W 3 % 1000 V 30.2 V 7.96 A 37.2 V 8.44 A -0.34 %/K 0.034 %/K Don't apply external voltages in excess of Uoc to the module 60 pc. 156 mm / 156 mm MC-PV4, cable 0.95 m each (+ / ) Anodized aluminium 1675 mm / 1001 mm / 34 mm 22 kg 5400 N/m 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and then a maximum output reduction of 0.7 % per year The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Minor reduction in efciency under partial load conditions at 25C: at 200 W/m, 95 % (3 %) of the STC efciency (1000 W/m) is achieved.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Suntech Mono Featuring monocrystalline 5" cells


Solar modules for all applications
The monocrystalline solar modules of Suntech can be used in almost all applications. Both in grid-connected and stand-alone systems, the modules prove themselves with their great reliability and optimal efciency. With its Black Mono series Suntech offers visually attractive modules. The Pluto series provides extremely efcient modules. 170, 175 and 180 Watt and combine highest efciency with a perfect look.

Pluto

34

Black Mono

With the modules of the Pluto series Suntech introduces a new series of high-performance modules. With 10 to 15 % more efciency and up to 12 % higher energy yields during twilight, the modules of the Pluto series are among the monocrystalline top models by Suntech.

Suntech's Black Mono modules are characterised by their elegant and simple look and are thus especially suitable for visually attractive systems. The extraordinarily efcient modules are available with outputs of

Advantages in brief
n n n n

Great reliability Optimal efciency Low output tolerance Sturdy design for wind and snow loads

The optimised back of the cell and improved anti-reex coating at the cell front ensure high efciency of Suntech solar cells.

The black foil on the back gives the Black Mono modules a homogenous and aesthetically pleasing appearance.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101161

0101162

0101163

0101164

0101165

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Suntech STP170S-24/Ad Mono 170 W +5 W, -0 W 1000 V DC 35.6 V 4.80 A 44.4 V 5.15 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101166

Suntech STP175S-24/Ad Mono 175 W +5 W, -0 W 1000 V DC 35.8 V 4.90 A 44.7 V 5.23 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101167

Suntech STP180S-24/Ad Mono 180 W +5 W, -0 W 1000 V DC 36.0 V 5.00 A 44.8 V 5.29 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101168

Suntech STP185S-24/Ad Mono 185 W +5 W, -0 W 1000 V DC 36.4 V 5.09 A 45.0 V 5.43 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101169

Suntech STP170S-24/Ad Black Mono 170 W +5 W, -0 W 1000 V DC 35.6 V 4.80 A 44.4 V 5.15 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101170

35

Art. No.

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Suntech STP175S-24/Ad Black Mono 175 W +5 W, -0 W 1000 V DC 35.8 V 4.90 A 44.7 V 5.23 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech STP180S-24/Ad Black Mono 180 W +5 W, -0 W 1000 V DC 36.0 V 5.00 A 44.8 V 5.29 A -0.48 %/C -0.34 %/C 0.037 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech PLUTO195-Ade Mono 195 W +5 W, -0 W 1000 V DC 37.6 V 5.19 A 45.4 V 5.52 A -0.38 %/C -0.29 %/C 0.046 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech PLUTO200-Ade Mono 200 W +5 W, -0 W 1000 V DC 37.9 V 5.28 A 45.7 V 5.62 A -0.38 %/C -0.29 %/C 0.046 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech PLUTO205-Ade Mono 205 W +5 W, -0 W 1000 V DC 38.1 V 5.38 A 45.8 V 5.73 A -0.38 %/C -0.29 %/C 0.046 %/C -40 to +85 C 72 pc. Monocrystalline silicon 125 mm / 125 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1580 mm / 808 mm / 35 mm 15.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

* - Manufacturer's performance warranty: 12 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Framed Modules

Suntech Poly Featuring polycrystalline 6" cells


Innovative cutting-edge technology lets Suntech Poly modules achieve great efciency. The great reliability with a guaranteed output tolerance of 3% and the excellent quality of the used components ensure permanently great efciency.

Efciency

Quality

36

During the manufacture of Suntech modules regular quality controls are carried out according to international standards. Manufacturing is certied according to ISO 9001:2000 (quality management system) and ISO 14001:2004 (environmental management system).

Applications

Be it as stand-alone systems or grid-connected, on the roof, the building exterior or on the ground, Suntech's Poly modules can be used almost anywhere. The modules have been designed for high wind and snow loads and certied according to IEC 61215.

Advantages in brief
n n n n

Great efciency Best reliability Low output tolerance Sturdy design

Due to their sturdy design, the Suntech modules are tested and approved for loads up to 5400 N/m.

All Suntech modules have a special connecting box, developed in collaboration with the Swiss company Huber+Suhner.

................................................................................................................................................................... ...................................................................................................................................................................
Framed Modules SOLAR MODULES

Art. No.

0101171

0101172

0101173

0101174

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms Art. No.

Suntech STP190-18/Ud Poly 190 W +5 W, -0 W 1000 V DC 26.0 V 7.31 A 33.0 V 7.89 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 54 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1482 mm / 992 mm / 35 mm 16.8 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101175

Suntech STP200-18/Ud Poly 200 W +5 W, -0 W 1000 V DC 26.2 V 7.63 A 33.4 V 8.12 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 54 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1482 mm / 992 mm / 35 mm 16.8 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101176

Suntech STP210-18/Ud Poly 210 W +5 W, -0 W 1000 V DC 26.4 V 7.95 A 33.6 V 8.33 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 54 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1482 mm / 992 mm / 35 mm 16.8 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101177

Suntech STP220-20/Wd Poly 220 W +5 W, -0 W 1000 V DC 29.5 V 7.46 A 36.6 V 8.05 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 60 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1665 mm / 991 mm / 50 mm 22.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark 0101178

37

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Suntech STP225-20/Wd Poly 225 W +5 W, -0 W 1000 V DC 29.6 V 7.61 A 36.7 V 8.15 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 60 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1665 mm / 991 mm / 50 mm 22.5 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech STP260-24/Vd Poly 260 W +5 W, -0 W 1000 V DC 34.8 V 7.47 A 44.0 V 8.09 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 72 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1956 mm / 992 mm / 50 mm 27.0 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech STP270-24/Vd Poly 270 W +5 W, -0 W 1000 V DC 35.0 V 7.71 A 44.5 V 8.20 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 72 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1956 mm / 992 mm / 50 mm 27.0 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

Suntech STP280-24/Vd Poly 280 W +5 W, -0 W 1000 V DC 35.2 V 7.95 A 44.8 V 8.33 A -0.47 %/C -0.34 %/C 0.045 %/C -40 to +85 C 72 pc. Polycrystalline silicon 156 mm / 156 mm Radox cables 4 mm with Radox solar connectors Anodized aluminium 1956 mm / 992 mm / 50 mm 27.0 kg (approx.) 5400 N/m 12 / 25 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, CE mark

* - Manufacturer's performance warranty: 12 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

...................................................................................................................................................................

Frameless Modules

Frameless high-efciency photovoltaic laminates


Advanced technology
Thanks to Kyocera's advanced cell processing technology, intensive research and automated production facilities they are able to produce a highly efcient polycrystalline photovoltaic module. back with PET lm, the laminates promise a durable, high-quality roof surface with little need for repair and maintenance. The distance between the cells and the module edge is a little wider than that of framed modules. The back of the junction box is equipped with bypass diodes that eliminate the risk of the individual solar cells overheating (hot spot effect). The solar cables ensure exible installation in the junction box. Kyocera manufactures all components in its own manufacturing plants without the acquisition of semi nished products for a constantly high quality of its products.

38

The embedded Kyocera high-performance solar cells with the basic measurement 15.6 x 15.6 cm achieve an efciency of over 16 % and guarantee an extremely high annual energy output of the photovoltaic plant.

High efciency

High-quality and reliability

The frameless modules do not require energy for the aluminium frames and thus ensure a further reduction in production energy. The cells are encapsulated between a non-reecting, tempered glass cover and an EVA pottant with a PVF back sheet. Sealed on the

Range of application
n n n

Grid-coupled systems Facade systems In-roof systems (e.g. Solrif)

Due to their frameless design, the modules can easily be mounted in facade or in-roof systems. The module is protected from the most severe environmental conditions.

The ISES SolarCarpot system includes 108 FL modules with an output of 14.04 kWp. Thanks to the frameless modules, this system does not require conventional roof cladding.

................................................................................................................................................................... ...................................................................................................................................................................
Frameless Modules SOLAR MODULES

Art. No.

0101105

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient voltage Temp. coefcient current NOCT Cells per module Cell dimensions Cell connection Connection Dimensions (L / W / H) * Weight Max. load Performance warranty ** Product warranty Norms

FD135GH-2P 135 W 5 % 1000 V 17.7 V 7.63 A 22.1 V 8.37 A -0.8 x 10 V/C 5.02 x 10 A/C 47.9 C 36 pc. 156 x 156 mm 3 Bus Bar MC PV-KBT3 / MC PV-KST3, cables, 840 (-) / 840 (+) mm 1499 mm / 708 mm / 5 mm 10.9 kg 2400 N/m 10 years 5 years IEC 61730, IEC 61215 ed. 2, protection class II, TVdotCOM-ID: 0000023420

39

* - The connection box at the back of each module protrudes the height of module. At this point the module has a height of 25 mm (FD135GH-2P). ** - Manufacturer's performance warranty: 10 years on 90 % and, in combination with Solrif, 20 years on 80 % of the minimal nominal power under standard testing conditions (STC) The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Grid-connected Inverters
Leading grid-connected inverters of our range safeguard maximum energy yields be it string inverters or central inverters with maximum efciency.

TRITEC BY DANFOSS KACO TRITEC BY SMA SMA


41

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Danfoss UniLynx The rst inverters with power modules


Danfoss UniLynx inverters are available with outputs of 1.8 kW, 3.0 kW, 3.6 kW or 5.4 kW and equipped with an integrated mechanical DC disconnector. All inverters have an easy-to-use LC display and are suitable for outdoor use. 42 tion compartment that is separate from the electronics, which offers greatest possible security for the installation as well as the electronics.

Communication and accessories

The inverters optionally have two input voltage ranges: the high voltage range (HV) is suitable for modules with 5" cells; the medium range (MV) is ideal for 6" cells. These two special voltage ranges prevent output losses through optimal adjustment of the string voltages to the operating area of the inverters.

Optimised for the use of solar modules with 5" and 6" cells

The electrical measurements of the inverters e.g. power course, energy yield, current, voltage and frequency can be gathered, saved and evaluated using optional dataloggers (e.g. Solar-Log). All inverters are equipped with a RS485-interface and are compatible to several datalogger manufacturers.

Features and innovations


n n n

Power module and separate connection compartment

At the heart of these inverters are power modules: compact power semiconductors which replace the previously used discrete power semiconductors. The HFtransformer technology separates the DC-side galvanic from the public AC-grid. The inverters have a connec-

n n n

First inverters with power modules RS485 communication network Choice between independent MPP trackers (greatest possible exibility) and Master-Slave operation (best efciency) International inverter for 16 countries Integrated DC-switch as a standard feature Ride Through even during massive power failures, the inverter continues to supply electricity

The internationally exible Danfoss UniLynx inverters with integrated HF transformer, DC switch and RS485 communication interface.

Due to the use of power modules, the heat generated is optimally dissipated the cooler the inverter, the longer its expected life.

................................................................................................................................................................... ...................................................................................................................................................................
Single-phased GRID-CONNECTED INVERTERS

Art. No.

0201194

0201195

0201196

0201197

Model Danfoss ULX 1800 MV (outdoor) Max. recommended PV system 1950 W power Max. DC output 1950 W Max. input current 10 A Max. input voltage * 450 / 410 V MPPT range 180 - 350 V Operation modes One MPP tracker Independent MPPT trackers Max. output power Nominal output power Output voltage Max. output current Nominal output current Start-up power level Stand-by power consumption Max. efciency Euro efciency Operating temperature Rel. humidity Protection mode Circuit type Power factor (P > 20 %) Harmonic distortion Galvanic safety class Surge protection AC + DC DC load disconnector Reverse-polarity protection Data communication Connection Dimensions (W / H / D) ** Weight Warranty *** Norms

Danfoss ULX 1800 HV (outdoor) 1950 W 1950 W 7A 600 / 550 V 260 - 500 V One MPP tracker

Danfoss ULX 3000 MV (outdoor) 3200 W

Danfoss ULX 3000 HV (outdoor) 3200 W 3200 W 2x7A 600 / 550 V 260 - 500 V Two independent MPP trackers or Master-Slave with one MPP tracker 2 pc. 3000 W 2750 W 230 V 0.15 % 13.0 A 12.0 A 20 W 8W 94.2 % 92.9 % -25 to +60 C 0 - 95 % IP54 High frequency transformer, single-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, for the connection of optional datalogger MC-PV4 618 mm / 434 mm / 192 mm 20 kg 5 years 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160

3200 W 2 x 10 A 450 / 410 V 180 - 350 V Two independent MPP trackers or Master-Slave with one MPP tracker 1 pc. 1 pc. 2 pc. 1800 W 1800 W 3000 W 1650 W 1650 W 2750 W 230 V 0.15 % 230 V 0.15 % 230 V 0.15 % 8.0 A 8.0 A 13.0 A 7.2 A 7.2 A 12.0 A 20 W 20 W 20 W 8W 8W 8W 93.7 % 93.7 % 94.2 % 91.6 % 91.6 % 92.9 % -25 to +60 C -25 to +60 C -25 to +60 C 0 - 95 % 0 - 95 % 0 - 95 % IP54 IP54 IP54 High frequency transformer, High frequency transformer, High frequency transformer, single-phased single-phased single-phased 0.97 0.97 0.97 <5% <5% <5% Class I Class I Class I Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated RS485 interface, for the RS485 interface, for the RS485 interface, for the connection of optional connection of optional connection of optional datalogger datalogger datalogger MC-PV4 MC-PV4 MC-PV4 489 mm / 434 mm / 192 mm 489 mm / 434 mm / 192 mm 618 mm / 434 mm / 192 mm 17 kg 17 kg 20 kg 5 years 5 years 5 years 73/23/EC, 2004/108/EC, EN 73/23/EC, 2004/108/EC, EN 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 50178, EN 61000-6-1, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14- 61000-6-2, EN 61000-4-13-14- 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, 28, EN 60146-1, EN 61000-6-3, 28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, EN 61000-6-4, EN 61000-3-2-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, EN 50160 EN 50160 EN 50160

43

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Art. No.

0201198

0201199

0201200

0201201

44

Model Danfoss ULX 3600 MV (outdoor) Max. recommended PV system 3900 W power Max. DC output 3900 W Max. input current 2 x 10 A Max. input voltage * 450 / 410 V MPPT range 180 - 350 V Operation modes Two independent MPP trackers or Master-Slave with one MPP tracker Independent MPPT trackers 2 pc. Max. output power 3600 W Nominal output power 3300 W Output voltage 230 V 0.15 % Max. output current 15.5 A Nominal output current 14.5 A Start-up power level 20 W Stand-by power consumption 8 W Max. efciency 94.2 % Euro efciency 93.4 % Operating temperature -25 to +60 C Rel. humidity 0 - 95 % Protection mode IP54 Circuit type High frequency transformer, single-phased Power factor (P > 20 %) 0.97 Harmonic distortion <5% Galvanic safety class Class I Surge protection AC + DC Integrated DC load disconnector Integrated Reverse-polarity protection Integrated Data communication RS485 interface, for the connection of optional datalogger Connection MC-PV4 Dimensions (W / H / D) ** 618 mm / 434 mm / 192 mm Weight 20 kg Warranty *** 5 years Norms 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 * - Reduced max. input voltage in master-slave operation ** - Incl. wall xing *** - Can optionally be extended to 10 years

Danfoss ULX 3600 HV (outdoor) 3900 W 3900 W 2x7A 600 / 550 V 260 - 500 V Two independent MPP trackers or Master-Slave with one MPP tracker 2 pc. 3600 W 3300 W 230 V 0.15 % 15.5 A 14.5 A 20 W 8W 94.2 % 93.4 % -25 to +60 C 0 - 95 % IP54 High frequency transformer, single-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, for the connection of optional datalogger MC-PV4 618 mm / 434 mm / 192 mm 20 kg 5 years 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160

Danfoss ULX 5400 MV (outdoor) 5400 W 5850 W 3 x 10 A 450 / 410 V 180 - 350 V Three independent MPP trackers or Master-Slave with one MPP tracker 3 pc. 5000 / 5400 W 4600 W 230 V 0.15 % 23.0 A 20.0 A 20 W 8W 94.3 % 93.4 % -25 to +60 C 0 - 95 % IP54 High frequency transformer, single-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, for the connection of optional datalogger MC-PV4 747 mm / 434 mm / 192 mm 23 kg 5 years 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160

Danfoss ULX 5400 HV (outdoor) 5400 W 5850 W 3x7A 600 / 550 V 260 - 500 V Three independent MPP trackers or Master-Slave with one MPP tracker 3 pc. 5000 / 5400 W 4600 W 230 V 0.15 % 23.0 A 20.0 A 20 W 8W 94.3 % 93.4 % -25 to +60 C 0 - 95 % IP54 High frequency transformer, single-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, for the connection of optional datalogger MC-PV4 747 mm / 434 mm / 192 mm 23 kg 5 years 73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-1428, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

45

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Kaco Powador 02 Series Great exibility, simple installation


New current sensor
The new current sensor of the Kaco Powador 02 series enables more precise control and better MPP tracking. The inverters with electrical isolation satisfy with their effortless installation, highest efciency as well as optimal operation by means of thin-lm modules. 46

Highest efciency

Effortless installation

With an efciency of 96 %, the inverters of the Kaco Powador 02 series are among the top-rated of their class. Due to the electrical isolation, the devices can be installed even in places that would be impossible for devices without transformers. The wide input voltage range makes the devices extremely exible.

The connections are situated on their own PCB within the casing and can be connected easily. For a faster and easier wiring, all communication connections are mounted separately on a PCB. A DC circuit breaker is integrated into the device.

Advantages in brief
n n n n n n n

New current sensor Electrical isolation Simple installation High efciency Simple wiring Optimal for thin-lm modules Display of earthing status of the PV generator

The integrated transformer of the Powador 02 series ensures electrical isolation from the mains, which allows the use of thin-lm modules without any problems.

With an efciency of 96 %, the inverters of the Kaco Powador 02 series are among the top-rated of their class.

................................................................................................................................................................... ...................................................................................................................................................................
Single-phased GRID-CONNECTED INVERTERS

Art. No.

0201124

0201126

0201128

0201130

0201132

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type DC load disconnector Grid monitoring Display Connection Casing Dimensions (W / H / D) Weight Warranty * Norms

Kaco Powador 2002 INT 125 - 510 V 600 V 14.3 A 1650 W 184 - 264 V 1 50 Hz <3% 95.9 % 95.3 % 0.4 W -20 to +60 C Free convection / no fan IP54 Self-controlled, electrically isolated, HF transformer Integrated Automatic disconnect switch DIN VDE 0126-11:2006-02 Two-line LC display, LED PCB clip up to max. 6 mm Aluminium 450 mm / 340 mm / 200 mm 12 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 3002 INT 200 - 510 V 600 V 13.5 A 2500 W 184 - 264 V 1 50 Hz <3% 96.0 % 95.4 % 0.4 W -20 to +60 C Free convection / no fan IP54 Self-controlled, electrically isolated, HF transformer Integrated Automatic disconnect switch DIN VDE 0126-11:2006-02 Two-line LC display, LED PCB clip up to max. 6 mm Aluminium 500 mm / 340 mm / 200 mm 20 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 4202 INT 200 - 510 V 600 V 18.5 A 3500 W 184 - 264 V 1 50 Hz <3% 95.9 % 95.1 % 0.4 W -25 to +60 C Free convection / no fan IP54 Self-controlled, electrically isolated, HF transformer Integrated Automatic disconnect switch DIN VDE 0126-11:2006-02 Two-line LC display, LED PCB clip up to max. 6 mm Aluminium 600 mm / 340 mm / 240 mm 26 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 5002 INT 200 - 510 V 600 V 22.4 A 4200 W 184 - 264 V 1 50 Hz <3% 95.9 % 95.3 % 0.4 W -25 to +60 C Fan IP54 Self-controlled, electrically isolated, HF transformer Integrated Automatic disconnect switch DIN VDE 0126-11:2006-02 Two-line LC display, LED PCB clip up to max. 6 mm Aluminium 600 mm / 340 mm / 240 mm 28 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 6002 INT 200 - 510 V 600 V 26.5 A 4600 W 184 - 264 V 1 50 Hz <3% 95.9 % 95.3 % 0.4 W -25 to +60 C Fan IP54 Self-controlled, electrically isolated, HF transformer Integrated Automatic disconnect switch DIN VDE 0126-11:2006-02 Two-line LC display, LED PCB clip up to max. 6 mm Aluminium 600 mm / 340 mm / 240 mm 28 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

47

* - Can optionally be extended to 11 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Kaco Powador xi Series Inverters without transformers


Higher efciency
Without transformers, the inverters of the Kaco xi series achieve optimal efciency. As a specialist for inverters without transformers, Kaco has equipped all devices of the xi series with a full bridge and omitted the boost converters. The self-controlled devices emulate the sinus voltage curve of the public power grid using a H4 bridge. Prerequisite for using the xi series inverters is an input voltage higher than the grid peak voltage. rent-operated protective device, facilitates the grid connection, even in the case of systems with several inverters.

Long service life

48

All inverters operate up to outputs of 8 kW with silent and purely passive cooling. The lost heat is optimally dissipated by the cooling element on the back. This cooling without mechanical fans reduces error sources and thus achieves a long life-cycle of the devices.

Simple installation

With a MPP range of 350 to 600 V and an off-load voltage of 800 V the conditions for a simple system dimensioning are ideal. The devices are connected to the grid by screw terminals. The redundant 3-phase monitoring, including an AC/DC sensitive residual-cur-

100 % feed-in

The Kaco Powador 6650xi was specically developed for applications with connections limits of 20 kW. Due to the 100 % symmetrical feed-in of 20 kW, not one watt of power is wasted, not even in Spain, Italy or Greece.

The Powador 2500xi to 4500xi without transformers can be single-phase connected individually, due to their nominal output.

The single-phase Powador 5000xi 8000xi have a nominal output of more than 5 kW; for this reason the unbalanced load between feed-in phases should be considered during the dimensioning.

................................................................................................................................................................... ...................................................................................................................................................................
Single-phased GRID-CONNECTED INVERTERS

Art. No.

0201134

0201136

0201138

0201140

0201142

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type DC load disconnector Grid monitoring

Display Connection Casing Dimensions (W / H / D) Weight Warranty * Norms

Kaco Powador 2500xi DCS INT 350 - 600 V 800 V 8.6 A 2600 W 190 - 264 V 1 50 Hz <3% 96.4 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 500 mm / 340 mm / 200 mm 19 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 3600xi DCS INT 350 - 600 V 800 V 12.0 A 3600 W 190 - 264 V 1 50 Hz <3% 96.4 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 550 mm / 340 mm / 220 mm 21 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 4000xi DCS INT 350 - 600 V 800 V 14.5 A 4400 W 190 - 264 V 1 50 Hz <3% 96.4 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 550 mm / 340 mm / 220 mm 26 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 4500xi DCS INT 350 - 600 V 800 V 15.2 A 4600 W 190 - 264 V 1 50 Hz <3% 96.3 % 95.3 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 600 mm / 340 mm / 220 mm 28 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 5000xi DCS INT 350 - 600 V 800 V 18.0 A 5500 W 190 - 264 V 1 50 Hz <3% 96.3 % 95.3 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 600 mm / 340 mm / 220 mm 30 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

49

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Art. No.

0201144

0201146

0201148

0201150

0201152

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type DC load disconnector Grid monitoring

50

Display Connection Casing Dimensions (W / H / D) Weight Warranty * Norms

Kaco Powador 6400xi DCS INT 350 - 600 V 800 V 19.0 A 6400 W 190 - 264 V 1 50 Hz <3% 96.5 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 810 mm / 340 mm / 220 mm 38 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 6650xi DCS INT 350 - 600 V 800 V 19.7 A 6650 W 190 - 264 V 1 50 Hz <3% 96.5 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 810 mm / 340 mm / 220 mm 38 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 7200xi DCS INT 350 - 600 V 800 V 21.4 A 7200 W 190 - 264 V 1 50 Hz <3% 96.5 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 810 mm / 340 mm / 220 mm 38 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 8000xi DCS INT 350 - 600 V 800 V 24.0 A 8000 W 190 - 264 V 1 50 Hz <3% 96.5 % 95.8 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 810 mm / 340 mm / 220 mm 38 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

Kaco Powador 4000 supreme INT 350 - 510 V 600 V 14.5 A 4400 W 190 - 264 V 1 50 Hz <3% 97.0 % 96.6 % 0W -20 to +60 C Free convection / no fan IP54 Self-controlled, transformerless Integrated Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Two-line LC display PCB clip up to max. 6 mm Aluminium 550 mm / 340 mm / 220 mm 26 kg 7 years DIN VDE 0126-1-1:200602, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966)

* - Can optionally be extended to 11 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

51

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

SMA Sunny Boy


Flexible pioneers
In addition, transformer-based devices offer the best possibilities for combination with thinlm modules.

52

As the rst manufacturer of an inverter suitable for mass production, SMA has concentrated on repeatedly diversifying the implementation possibilities with new technologies, so that today any system constellation from 400 Wp and upwards can be optimally realized with an SMA inverter. SMA develops and manufactures the inverters for a life span of more than 20 years and produces exclusively at the company headquarters in Niestetal, near Kassel, Germany. The new, elegant design was developed in a joint effort by TRITEC and SMA.

The new generation: globally communicative

Just radio where previously cables were required Bluetooth makes it possible. The Sunny Boys of the new generation (SB 4000TL-20, SB 5000TL-20) are provided with this innovative radio technology. Set for international action: the new Sunny Boy speaks German, English, French, Spanish, Italian, and Greek.

The choice is yours: with or without transformer

Easy installation of the new Sunny Boy

SMA inverters are available with or without transformers. While the transformerless concept offers the ability to use such latest technologies as H5 topology and is also extremely lightweight, the transformer device is the rst choice for those who want galvanic isolation.

In addition to its completely new installation and wiring concept, the new Sunny Boy is not only 20 percent lighter, it is also clearly reduced in volume. Installation in a ash on a top hat rail or wall xture is thus guaranteed. The concept is rounded off by wiring without tools due to special SMA spring-type clamps and effective anti-theft device.

Globally the most successful inverters of the Sunny Boy series, now in the new TRITEC design.

The new generation of the Sunny Boy series: with Bluetooth and exible country settings as standard.

................................................................................................................................................................... ...................................................................................................................................................................
Single-phased GRID-CONNECTED INVERTERS

Art. No.

0201110

0201017

0201018

0201019

0201020

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms Art. No.

SMA SB 1200 100 - 320 V 400 V 12.6 A 1200 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 92.1 % 90.7 % 0.10 W -25 to +60 C 0 to 98 %, no condensation Convection IP65 Low frequency transformer, singlephased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 434 mm / 295 mm / 214 mm 23 kg 5 years CE mark, VDE 0126 0201021

SMA SB 1700 139 - 320 V 400 V 12 A 1550 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 93.5 % 91.8 % 0.10 W -25 to +60 C 0 to 98 %, no condensation Convection IP65 Low frequency transformer, singlephased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 434 mm / 295 mm / 214 mm 25 kg 5 years CE mark, VDE 0126 0201023

SMA SB 2100TL SMA SB 2500 125 - 600 V 224 - 480 V 600 V 600 V 11 A 12 A 1950 W 2300 W 180 - 260 V 180 - 260 V 1 1 50 Hz 4.5 Hz 50 Hz 4.5 Hz <4% <4% 96.0 % 94.1 % 95.2 % 93.2 % 0.25 W 0.25 W -25 to +60 C -25 to +60 C 0 to 98 %, no 0 to 95 %, no condensation condensation Convection Convection IP65 IP65 Transformerless, single- Low frequency phased transformer, singlephased ENS, according to VDE ENS, according to VDE 0126 0126 Fault current Fault current monitoring according monitoring according to VDE 0126 to VDE 0126 Two-line LC display Two-line LC display Aluminium Aluminium 434 mm / 295 mm / 434 mm / 295 mm / 214 mm 214 mm 16 kg 30 kg 5 years 5 years CE mark, VDE 0126 CE mark, VDE 0126 0201026

SMA SB 3000 268 - 480 V 600 V 12 A 2750 W 180 - 260 V > 0.98 50 Hz 4.5 Hz <4% 95.0 % 93.6 % 0.25 W -25 to +60 C 0 to 95 %, no condensation Convection IP65 Low frequency transformer, singlephased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 434 mm / 295 mm / 214 mm 31 kg 5 years CE mark, VDE 0126

53

0201027

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms Continued on next page

SMA SB 3300 200 - 400 V 500 V 20 A 3300 W 180 - 260 V > 0.98 50 Hz 4.5 Hz <4% 95.2 % 94.4 % 0.25 W -25 to +60 C 0 to 95 %, no condensation OptiCool fan IP65 Low frequency transformer, single-phased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 450 mm / 352 mm / 236 mm 41 kg 5 years CE mark, VDE 0126

SMA SB 3800 200 - 400 V 500 V 20 A 3800 W 180 - 260 V > 0.98 50 Hz 4.5 Hz <4% 95.6 % 94.7 % 0.25 W -25 to +60 C 0 to 95 %, no condensation OptiCool fan IP65 Low frequency transformer, single-phased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 450 mm / 352 mm / 236 mm 41 kg 5 years CE mark, VDE 0126

SMA SB 3000TL-20 125 - 440 V 550 V 1 x 17 A 3000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 97.0 % 96.0 % 0.20 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 470 mm / 445 mm / 180 mm 25 kg 5 years CE mark, VDE 0126

SMA SB 4000TL-20 125 - 440 V 550 V 2 x 15 A 4000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 97.0 % 96.2 % 0.20 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 470 mm / 445 mm / 180 mm 25 kg 5 years CE mark, VDE 0126

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Art. No.

0201028

0201118

0201119

0201120

54

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms

SMA SB 5000TL-20 125 - 440 V 550 V 2 x 15 A 4600 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 97.0 % 96.5 % 0.20 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 470 mm / 445 mm / 180 mm 25 kg 5 years CE mark, VDE 0126

SMA SB 2000HF 175 - 560 V 700 V 12 A 2000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.0 % 95.0 % 0.25 W -25 to +60 C 0 to 98 %, no condensation IP65 High frequency transformer, single-phased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 348 mm / 580 mm / 145 mm < 18 kg 5 years CE mark, VDE 0126

SMA SB 2500HF 175 - 560 V 700 V 15 A 2500 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.0 % 95.0 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 High frequency transformer, single-phased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 348 mm / 580 mm / 145 mm < 18 kg 5 years CE mark, VDE 0126

SMA SB 3000HF 210 - 560 V 700 V 15 A 3000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.0 % 95.0 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 High frequency transformer, single-phased ENS, according to VDE 0126 Fault current monitoring according to VDE 0126 Graphic LC display Aluminium 348 mm / 580 mm / 145 mm < 18 kg 5 years CE mark, VDE 0126

* - Can optionally be extended to 10 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

55

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

SMA Sunny Mini Central


Innovative technology Dual concept

56

As the rst inverter with the SMA-developed H5 topology, the transformerless Sunny Mini Central can operate at an efciency level of over 98 %. The transformerless Sunny Mini Central hence offers the shortest amortization time available today. The inverter also includes Power Balancer, an intelligent unbalanced load management system that guarantees optimal compliance with power utility company guidelines.

Optimal error safety

The Sunny Mini Central is available with or without a transformer. While the transformerless concept offers the ability to use the latest technologies like H5 topology and is also extremely light weight, the transformer device is the rst choice for those who want galvanic isolation and an extended temperature range of up to 60C in ambient temperature. Regardless of which type is used you can choose from a wide range of different system monitoring components that offer you greater investment security.

With the Electronic Solar Switch DC integrated circuit breaker and the SMA Grid guard 2 active grid-monitoring system, the Sunny Mini Central is equipped with the most advanced safety features for all work on either the solar power system or the AC voltage grid. By wiring fewer strings per inverter, additional string monitoring is no longer necessary. Defects can be immediately identied on the integrated display of each Sunny Mini Central.

Advantages in brief
n n n n n n

The best price-performance ratio Elegant TRITEC design Highest efciency worldwide Protection class IP65 SMA OptiCool Electronic Solar Switch ESS

The established SMA Sunny Mini Central series in the attractive TRITEC design.

None pay for themselves as quickly as the efciency record holder SMA SMC 8000TL.

................................................................................................................................................................... ...................................................................................................................................................................
Single-phased GRID-CONNECTED INVERTERS

Art. No.

0201086

0201029

0201030

0201031

0201032

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms Art. No.

SMA SMC 4600A 246 - 480 V 600 V 26 A 4600 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.1 % 95.2 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Low frequency transformer, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 62 kg 5 years CE mark, VDE 0126 0201033

SMA SMC 5000A 246 - 480 V 600 V 26 A 5000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.1 % 95.2 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Low frequency transformer, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 62 kg 5 years CE mark, VDE 0126 0201034

SMA SMC 6000A 246 - 480 V 600 V 26 A 6000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.1 % 95.2 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Low frequency transformer, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 63 kg 5 years CE mark, VDE 0126 0201035

SMA SMC 6000TL 333 - 500 V 700 V 19 A 6000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 98.0 % 97.7 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 31 kg 5 years CE mark, VDE 0126

SMA SMC 7000HV 335 - 560 V 800 V 31 A 6650 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 96.1 % 95.3 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Low frequency transformer, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 65 kg 5 years CE mark, VDE 0126

57

0201036

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms Continued on next page

SMA SMC 7000TL 333 - 500 V 700 V 22 A 7000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 98.0 % 97.7 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 32 kg 5 years CE mark, VDE 0126

SMA SMC 8000TL 333 - 500 V 700 V 25 A 8000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 98.0 % 97.7 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 33 kg 5 years CE mark, VDE 0126

SMA SMC 9000TL 333 - 500 V 700 V 29 A 9000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 98.0 % 97.5 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 40 kg 5 years CE mark, VDE 0126

SMA SMC 10000TL 333 - 500 V 700 V 32 A 10000 W 180 - 260 V 1 50 Hz 4.5 Hz <4% 98.0 % 97.5 % 0.25 W -25 to +60 C 0 to 95 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 40 kg 5 years CE mark, VDE 0126

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Single-phased

Art. No.

0201037

0201107

0201108

0201109

58

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms

SMA SMC 11000TL 333 - 500 V 700 V 35 A 11000 W 180 - 260 V > 0.98 50 Hz 4.5 Hz <4% 98.0 % 97.5 % 0.25 W -25 to +60 C 0 to 95 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard 2 Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 40 kg 5 years CE mark, VDE 0126

SMA SMC 9000TLRP-10 333 - 500 V 700 V 28 A 9000 W 180 - 260 V 0.8 (leading) - 0.8 (lagging) 50 Hz 4.5 Hz <4% 97.7 % 97.5 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 35 kg 5 years CE mark, VDE 0126

SMA SMC 10000TLRP-10 333 - 500 V 700 V 31 A 10000 W 180 - 260 V 0.8 (leading) - 0.8 (lagging) 50 Hz 4.5 Hz <4% 97.7 % 97.5 % 0.25 W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 35 kg 5 years CE mark, VDE 0126

SMA SMC 11000TLRP-10 333 - 500 V 700 V 34 A 11000 W 180 - 260 V 0.8 (leading) - 0.8 (lagging) 50 Hz 4.5 Hz <4% 97.7 % 97.5 % 0.25 W -25 to +60 C 0 to 95 %, no condensation OptiCool fan IP65 Transformerless, singlephased SMA Grid guard Fault current monitoring according to VDE 0126 Two-line LC display Aluminium 468 mm / 613 mm / 242 mm 35 kg 5 years CE mark, VDE 0126

* - Can optionally be extended to 10 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

59

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Three-phased

Danfoss TripleLynx The most versatile inverter on the market


The three-phase Danfoss TripleLynx inverters are available with outputs of 10, 12.5 and 15 kW and are suitable for outdoor use, weighing a mere 35 kg. Due to their ease-of-use, geared to economic applications, and their wide range of operating specications, these inverters are the most versatile on the market. 60 ciency of 99.9 % of the MPP controller. With an effectiveness of 98 %, this inverter positions itself at the top of the three-phase devices on the market.

Three-phase grid connection

It's all there wide range of operating specications

The inverter has two or three independent string inputs, an extensive operating eld, and a three-phase output, which makes it incredibly versatile. Thanks to its wide range of operating specications, the inverter can be connected to a variety of modules each with different string congurations.

A perfectly symmetrical three-phase power supply requires nothing more than an inverter. A three-phase inverter ensures three-phase output at all times as well as compliance with the rules for grid connection irrespective of string uctuations on the input side.

Features and innovations


n n n n

High output due to effective MPP trackers and high efciency

n n n n n n

Three individual MPP controllers always ensure an optimal output of the system, irrespective of the differences in size or the location of the PV modules. The accuracy of the MPP controllers was veried by the Viennese Arsenal Research Institute, measuring an ef-

Up to three independent power inputs Preprogrammed for 16 countries Integrated communication board Communication with RS485 and integrated modem Alarm display for faults Integrated DC switch Integrated cable lock Integrated insulation monitoring Separate connection compartment Service tool for ultra-easy maintenance

The transformerless Danfoss TripleLynx inverter series with three-phase power supply and a sensational effectiveness of 98 %.

The TripleLynx inverters are optionally available as the Plus model (incl. reactive power compensation) and the Pro model (incl. web server).

................................................................................................................................................................... ...................................................................................................................................................................
Three-phased GRID-CONNECTED INVERTERS

Art. No.

0201202

0201205

0201208

0201211

Model Max. recommended PV system power Max. DC output Max. input current Max. input voltage MPPT range Independent MPPT trackers Max. output power Nominal output power Output voltage Max. output current Start-up power level Stand-by power consumption Max. efciency Euro efciency Operating temperature Rel. humidity Protection mode Circuit type Power factor (P > 20 %) Harmonic distortion Galvanic safety class Surge protection AC + DC DC load disconnector Reverse-polarity protection Data communication

Danfoss TLX 10k (standard) 11800 W 10300 W 2 x 12 (24) A 1000 V 430 - 800 V 2 pc. 10000 W 10000 W 3 x 230 V 20 % 3 x 15.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 10k (plus) 11800 W 10300 W 2 x 12 (24) A 1000 V 430 - 800 V 2 pc. 10000 W 10000 W 3 x 230 V 20 % 3 x 15.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit -

Danfoss TLX 10k (pro) 11800 W 10300 W 2 x 12 (24) A 1000 V 430 - 800 V 2 pc. 10000 W 10000 W 3 x 230 V 20 % 3 x 15.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 10k (plus pro) 11800 W

Reactive power Ethernet

Connection Dimensions (W / H / D) Weight Warranty * Norms

10300 W 2 x 12 (24) A 1000 V 430 - 800 V 2 pc. 10000 W 10000 W 3 x 230 V 20 % 3 x 15.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit Ethernet serial and Star, Ethernet serial and Star, software update from master, software update from master, allocation of settings from allocation of settings from master, web server master, web server MC-PV4 MC-PV4 MC-PV4 MC-PV4 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 35 kg 35 kg 35 kg 35 kg 5 years 5 years 5 years 5 years 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, EN 50160 EN 50160 EN 50160 EN 50160

61

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Three-phased

Art. No.

0201203

0201206

0201209

0201212

62

Model Max. recommended PV system power Max. DC output Max. input current Max. input voltage MPPT range Independent MPPT trackers Max. output power Nominal output power Output voltage Max. output current Start-up power level Stand-by power consumption Max. efciency Euro efciency Operating temperature Rel. humidity Protection mode Circuit type Power factor (P > 20 %) Harmonic distortion Galvanic safety class Surge protection AC + DC DC load disconnector Reverse-polarity protection Data communication

Danfoss TLX 12.5k (standard) 14700 W 12900 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 12500 W 12500 W 3 x 230 V 20 % 3 x 19.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 12.5k (plus) 14700 W 12900 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 12500 W 12500 W 3 x 230 V 20 % 3 x 19.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit -

Danfoss TLX 12.5k (pro) 14700 W 12900 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 12500 W 12500 W 3 x 230 V 20 % 3 x 19.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 12.5k (plus pro) 14700 W

Reactive power Ethernet

Connection Dimensions (W / H / D) Weight Warranty * Norms

12900 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 12500 W 12500 W 3 x 230 V 20 % 3 x 19.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit Ethernet serial and Star, Ethernet serial and Star, software update from master, software update from master, allocation of settings from allocation of settings from master, web server master, web server MC-PV4 MC-PV4 MC-PV4 MC-PV4 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 35 kg 35 kg 35 kg 35 kg 5 years 5 years 5 years 5 years 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, EN 50160 EN 50160 EN 50160 EN 50160

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

................................................................................................................................................................... ...................................................................................................................................................................
Three-phased GRID-CONNECTED INVERTERS

Art. No.

0201204

0201207

0201210

0201213

Model Max. recommended PV system power Max. DC output Max. input current Max. input voltage MPPT range Independent MPPT trackers Max. output power Nominal output power Output voltage Max. output current Start-up power level Stand-by power consumption Max. efciency Euro efciency Operating temperature Rel. humidity Protection mode Circuit type Power factor (P > 20 %) Harmonic distortion Galvanic safety class Surge protection AC + DC DC load disconnector Reverse-polarity protection Data communication

Danfoss TLX 15k (standard) 17700 W 15500 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 15000 W 15000 W 3 x 230 V 20 % 3 x 22.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 15k (plus) 17700 W 15500 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 15000 W 15000 W 3 x 230 V 20 % 3 x 22.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit -

Danfoss TLX 15k (pro) 17700 W 15500 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 15000 W 15000 W 3 x 230 V 20 % 3 x 22.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger -

Danfoss TLX 15k (plus pro) 17700 W

Reactive power Ethernet

Connection Dimensions (W / H / D) Weight Warranty * Norms

15500 W 3 x 12 (36) A 1000 V 430 - 800 V 3 pc. 15000 W 15000 W 3 x 230 V 20 % 3 x 22.0 A 20 W 10 W 98 % > 97 % -25 to +60 C 0 - 95 % non condensing IP54 Transformerless, three-phased 0.97 <5% Class I Integrated Integrated Integrated RS485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger Reactive power setting protection in display unit Ethernet serial and Star, Ethernet serial and Star, software update from master, software update from master, allocation of settings from allocation of settings from master, web server master, web server MC-PV4 MC-PV4 MC-PV4 MC-PV4 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 35 kg 35 kg 35 kg 35 kg 5 years 5 years 5 years 5 years 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, DIN VDE 0126-1-1, IEC 61727, EN 50160 EN 50160 EN 50160 EN 50160

63

* - Can optionally be extended to 10 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Three-phased

Kaco Powador central inverters Efcient and reliable


With generator outputs of 2 to 110 kW, the inverters of the Kaco Powador series cover an enormous performance range completely. The ability of combining all devices freely enables any project to be realised optimally and individually from single-family houses to megawatt solar parks.

Individual performance

Greatest exibility

64

The used components, technology and the ability to combine freely result in a very great exibility for all users. For instance, the Powador 5000xi can serve a photovoltaic system of up to 6.8 kW or with additional devices also other output classes, up to entire solar power plants.

Innovative technology

In all inverters of the Powador series a patented MPP control and innovative IGBT circuit breaker ensure high efciency. For all devices without transformers, Kaco has always preferred the 3-phase voltage monitoring to the simple impedance measuring (ENS). The 3-phase monitoring avoids unnecessary cut-offs, resulting in increased feed-in current. The grid monitoring by means of the bi-directional safety interface (BiSi), which is used in all inverters with transformers, offers the same advantages.

Advantages in brief
n n n n n

Generator output of 2 to 110 kW Ability to combine all devices Patented MPP control New IGBT circuit breaker 3-phase voltage monitoring for devices without transformers Grid monitoring by means of BiSi for devices with transformers Optionally available for Kaco Powador 25000xi / 30000xi / 33000xi: a park model (for solar parks) with increased efciency according to industry standards

Kaco Powador 25000xi / 30000xi / 33000xi can help to realise PV power systems of 25 kW to the megawatt range.

The Kaco Powador Megawatt Station consists of three combined XP350-HV TL.

................................................................................................................................................................... ...................................................................................................................................................................
Three-phased GRID-CONNECTED INVERTERS

Art. No.

0201155

0201157

0201159

0201167

0201169

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type Grid monitoring

Display DC load disconnector Line fuses Surge protection Casing Dimensions (W / H / D) Weight Warranty * Norms

Kaco Powador 25000xi M INT 350 - 600 V 800 V 3 x 27.4 A 25000 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Lit four-line LC display Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 610006-1:2007, EN 61000-62:2005, EN 61000-64:2007, EN 61000-311:2000, EN 61000-312:2005, DIN VDE 01261-1:2006-02

Kaco Powador 25000xi L INT 350 - 600 V 800 V 3 x 27.4 A 25000 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 610006-1:2007, EN 61000-62:2005, EN 61000-64:2007, EN 61000-311:2000, EN 61000-312:2005, DIN VDE 01261-1:2006-02

Kaco Powador 25000xi XL INT 350 - 600 V 800 V 3 x 27.4 A 25000 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 610006-1:2007, EN 61000-62:2005, EN 61000-64:2007, EN 61000-311:2000, EN 61000-312:2005, DIN VDE 01261-1:2006-02

Kaco Powador 30000xi M INT 350 - 600 V 800 V 3 x 32.8 A 29900 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Lit four-line LC display Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 610006-1:2007, EN 61000-62:2005, EN 61000-64:2007, EN 61000-311:2000, EN 61000-312:2005, DIN VDE 01261-1:2006-02

Kaco Powador 30000xi L INT 350 - 600 V 800 V 3 x 32.8 A 29900 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 0126-1-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 610006-1:2007, EN 61000-62:2005, EN 61000-64:2007, EN 61000-311:2000, EN 61000-312:2005, DIN VDE 01261-1:2006-02

65

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Three-phased

Art. No.

0201171

0201179

0201181

0201183

66

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type Grid monitoring Display DC load disconnector Line fuses Surge protection Casing Dimensions (W / H / D) Weight Warranty * Norms

Kaco Powador 30000xi XL INT 350 - 600 V 800 V 3 x 32.8 A 29900 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 01261-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 61000-61:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61000-311:2000, EN 61000-3-12:2005, DIN VDE 0126-1-1:2006-02

Kaco Powador 33000xi M INT 350 - 600 V 800 V 3 x 33.2 A 33300 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 01261-1:2006-02, VDEW-compliant Lit four-line LC display Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 61000-61:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61000-311:2000, EN 61000-3-12:2005, DIN VDE 0126-1-1:2006-02

Kaco Powador 33000xi L INT 350 - 600 V 800 V 3 x 33.2 A 33300 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 01261-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 61000-61:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61000-311:2000, EN 61000-3-12:2005, DIN VDE 0126-1-1:2006-02

Kaco Powador 33000xi XL INT 350 - 600 V 800 V 3 x 33.2 A 33300 W 190 - 264 V 1 50 Hz <3% 96.5 % 96.0 % 7W -20 to +60 C Forced cooling / speedcontrolled fan, max. 600 m/h IP54 Self-controlled, transformerless Redundant 3-phase monitoring acc. to VDE 01261-1:2006-02, VDEW-compliant Lit four-line LC display Integrated 5 line fuses (12 A) Integrated Sheet steel 1460 mm / 835 mm / 340 mm 190 kg 7 years EN 60950-1:2006, EN 50178:1997, EN 61000-61:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61000-311:2000, EN 61000-3-12:2005, DIN VDE 0126-1-1:2006-02

* - Can optionally be extended to 11 / 15 / 20 / 25 years Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

................................................................................................................................................................... ...................................................................................................................................................................
Three-phased GRID-CONNECTED INVERTERS

Art. No.

0201190

0201191

0201192

Model MPP voltage range Open circuit voltage Max. input current Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Heat dissipation Protection mode Circuit type Grid monitoring Display Casing Dimensions (W / H / D) Weight Warranty Norms

Kaco Powador XP100-HV INT 450 - 800 V 950 V 235 A 100000 W 400 V (10 %)

Kaco Powador Megawatt Station INT 450 - 830 V 1000 V 3 x 856 A 1050000 W According to country-specic requirements 0.9 inductive, 0.9 capacitive 0.9 inductive, 0.9 capacitive 0.9 inductive, 0.9 capacitive 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz <3% <3% <3% 97.1 % 98.2 % 98.2 % 96.5 % 97.8 % 97.8 % -20 to +50 C -20 to +50 C -20 to +50 C Fan (max. 2420 m/h) Fan (max. 6420 m/h) Fan (max. 18000 m/h) IP21 IP21 IP54 Digital control, with transformer Digital control, transformerless Digital control, transformerless According to country-specic According to country-specic According to country-specic requirements requirements requirements TFT LC display touch screen TFT LC display touch screen TFT LC display touch screen Sheet steel Sheet steel Sheet steel 2120 mm / 1200 mm / 920 mm 2110 mm / 2400 mm / 850 mm 7000 mm / 3000 mm / 3440 mm 1120 kg 1430 kg 35000 kg (approx.) 3 years 3 years 3 years EN 60950-1:2006, EN 50178:1997, EN EN 60950-1:2006, EN 50178:1997, EN EN 60950-1:2006, EN 50178:1997, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61000-3-11:2000, EN 61000-6-4:2007, EN 61000-3-11:2000, EN 61000-6-4:2007, EN 61000-3-11:2000, EN 61000-3-12:2005, DIN VDE 0126-1-1:2006- 61000-3-12:2005, DIN VDE 0126-1-1:2006- 61000-3-12:2005, DIN VDE 0126-1-1:200602 02 02

Kaco Powador XP350-HV TL INT 450 - 830 V 1000 V 856 A 350000 W 3 x 290 V (10 %) to external transformer

67

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Three-phased

SMA Sunny Tripower Three-phase feed for simple system planning


Cost-effective, safe and exible these qualities make the SMA Sunny Tripower inverters extremely efcient inverters. With an efciency of 98 %, open circuit voltage up to 1000 V and power ratings of 10 to 17 kW, the inverters are perfectly suited for all applications.

Greatest efciency

Best safety

68

The latest technology

The Sunny Tripower inverters meet the requirements of the VDEW Mean Voltage directives and are therefore a reliable part of the grid management. The safety concept with string failure detection, electronic string protection and integrable lightning protection function ensures greatest availability and reduces system costs.

The innovative product qualities of the Sunny Tripower series guarantee simple installation, high yields and safe grid support. The multi-string technology and the large input voltage range make the inverters ready for all system dimensioning from 10 kW to the megawatt range.

Advantages in brief
n n n

n n n n

Integrated DC circuit breaker ESS String current monitoring Flexible module dimensioning with two boost converters Tool-free cable connection Innovative DC connector system Easily accessible connection area Communication via Bluetooth

The SMA Sunny Tripower efcient, innovative and safe.

Monitoring of system data with the SMA Sunny Beam.

................................................................................................................................................................... ...................................................................................................................................................................
Three-phased GRID-CONNECTED INVERTERS

Art. No.

0201111

0201112

0201113

0201114

Model MPP voltage range Open circuit voltage Max. input current (Input A / Input B) MPP tracker Nominal output Output voltage Power factor cos phi Frequency Harmonic distortion Max. efciency Euro efciency Night-time consumption Ambient temperature Relative humidity Heat dissipation Protection mode Circuit type Grid monitoring Fault current monitoring Display Casing Dimensions (W / H / D) Weight Warranty * Norms

STP 10000TL-10 320 - 800 V 1000 V 22 A / 11 A 2 pc. 10000 W 230 / 400 V, three-phased 1 50 Hz 5 Hz <4% 98.1 % 97.7 % <1W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, three-phased SMA Grid guard Fault current monitoring according to VDE 0126 LCD graphics display Aluminium 665 mm / 690 mm / 265 mm 65 kg (approx.) 5 years CE mark, VDE 0126-1-1:200602

STP 12000TL-10 380 - 800 V 1000 V 22 A / 11 A 2 pc. 12000 W 230 / 400 V, three-phased 1 50 Hz 5 Hz <4% 98.1 % 97.7 % <1W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, three-phased SMA Grid guard Fault current monitoring according to VDE 0126 LCD graphics display Aluminium 665 mm / 690 mm / 265 mm 65 kg (approx.) 5 years CE mark, VDE 0126-1-1:200602

STP 15000TL-10 360 - 800 V 1000 V 33 A / 11 A 2 pc. 15000 W 230 / 400 V, three-phased 1 50 Hz 5 Hz <4% 98.1 % 97.7 % <1W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, three-phased SMA Grid guard Fault current monitoring according to VDE 0126 LCD graphics display Aluminium 665 mm / 690 mm / 265 mm 65 kg (approx.) 5 years CE mark, VDE 0126-1-1:200602

STP 17000TL-10 400 - 800 V 1000 V 33 A / 11 A 2 pc. 17000 W 230 / 400 V, three-phased 1 50 Hz 5 Hz <4% 98.1 % 97.7 % <1W -25 to +60 C 0 to 98 %, no condensation OptiCool fan IP65 Transformerless, three-phased SMA Grid guard Fault current monitoring according to VDE 0126 LCD graphics display Aluminium 665 mm / 690 mm / 265 mm 65 kg (approx.) 5 years CE mark, VDE 0126-1-1:200602

69

* - Can optionally be extended to 10 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Accessories

SMA communication products


Sunny Beam Complete system control without cables
cation center of your power supply system. On the system side, it continuously gathers all data from the inverters and thereby allows you to remain constantly informed of your system's status at any given time. As a multifunctional datalogger, it also offers you a wide range of possibilities for displayinig, archiving, and further processing the system data. The WebBox is the right choice for the ambitious system operator who wishes to document the system data completely and continuously. Even from remote locations, where no DSL or telephone connection is available, the PV system can display its measurement data at Sunny Portal via the optional GSM modem.

70

Convenient and practical, Sunny Beam lets you check on the status and yield of your solar energy system at a glance, and at any time. The Sunny Beam can monitor up to four inverters via wireless interfaces. The performance of the elegant tabletop device is just as impressive as its functionality. An integrated solar cell provides the electricity for truly cable-free operation. An integrated rechargeable battery ensures operation also in the absence of solar radiation. On a large graphic display, you can immediately see the present output, the daily graph, and the daily values of the previous 30 days. By pushing and rotating an operating dial, you can set the individual display settings as desired and select which results are to be displayed. In addition to its real-time display, Sunny Beam can also store yield data for the last 30 days. The integrated USB interface is used to read the saved plant data and to archive it on the PC by using the Sunny Data Control software included in the delivery.

Sunny SensorBox

Sunny WebBox The professional datalogger

It was specially developed to further rene performance analysis of solar power stations. With the Sunny SensorBox, it is now possible to acquire environmental data also, such as irradiation and module temperature, in order to detect any PV module faults or failures promptly. The Sunny SensorBox is simply connected with the inverters via the serial RS485 data link to a Sunny WebBox.

Plant monitoring, remote diagnosis, data acquisition and visualisation: The Sunny WebBox is the communi-

The radio-based Sunny Beam from SMA ensures easy and cost-effective system monitoring.

The SMA WebBox ensures professional monitoring of up to 50 inverters on the Internet.

................................................................................................................................................................... ...................................................................................................................................................................
Accessories GRID-CONNECTED INVERTERS

Art. No.

0201048

0201099

0201050

0201051

Model Interface Frequency Approx. range outdoors / indoors Display Handling Languages

SMA Sunny Beam incl. USB cable USB 1.1 868 MHz 100 / 30 m LCD, graphic display, 160 x 100 pixel Rotary push-button English / French / German / Spanish

SMA Sunny Beam Bluetooth USB 1.1 100 m LCD, graphic display, 160 x 100 pixel Rotary push-button English / French / German / Spanish / Italian / Portuguese / Dutch / Czech Bluetooth -/IP20 127 mm / 75 mm / 195 mm 350 g 2 years CE mark 0201100

SMA Sunny WebBox without modem Ethernet With RS485 up to 50 inverters 1 GB Power supply unit, 115 - 230 V 50 - 60 Hz 4 W / 12 W -20 to +55 C 5 - 95 % 225 mm / 130 mm / 57 mm 750 g 2 years CE mark 0201053

SMA Sunny WebBox with analog modem Ethernet, analog modem With RS485 up to 50 inverters 1 GB Power supply unit, 115 - 230 V 50 - 60 Hz 4 W / 12 W -20 to +55 C 5 - 95 % 225 mm / 130 mm / 57 mm 750 g 2 years CE mark

71

Data communication Radio Memory expansion SD card Solar irradiation measuring Module temperature sensor Power supply Frequency range of power supply unit Power consumption (nominal / - / max.) Ambient temperature Rel. humidity Protection mode IP20 Dimensions (W / H / D) 127 mm / 75 mm / 195 mm Weight 350 g Warranty 2 years Norms CE mark Art. No. 0201052

Model

SMA Sunny WebBox with GSM modem

SMA Sunny WebBox Bluetooth Ethernet With Bluetooth up to 50 inverters 1 GB Power supply unit, 115 - 230 V 50 - 60 Hz 4 W / 12 W -20 to +55 C 5 - 95 % 225 mm / 130 mm / 57 mm 750 g 2 years CE mark

Interface Ethernet, GSM modem Frequency Approx. range outdoors / indoors Display Handling Languages Data communication With RS485 up to 50 inverters Memory expansion SD card 1 GB Solar irradiation measuring Module temperature sensor Power supply Power supply unit, 115 - 230 V Frequency range of power 50 - 60 Hz supply unit Power consumption (nominal / 4 W / 12 W max.) Ambient temperature -20 to +55 C Rel. humidity 5 - 95 % Protection mode Dimensions (W / H / D) 225 mm / 130 mm / 57 mm Weight 750 g Warranty 2 years Norms CE mark Continued on next page

SMA Sunny Sensor Box with mounting plate RS485 to Sunny WebBox ASI solar module, precision 8 % Pt100, precision 0.5 C Via RS485 line from Sunny WebBox 50 - 60 Hz -/-25 to +70 C IP65 120 mm / 90 mm / 50 mm 500 g 2 years CE mark

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Accessories

Accessories Art. No. Model Function

0201049 SMA Piggy Back wireless Radio transmission from Sunny Boy to Sunny Beam Up to 4 inverters Add-on kit A 2 years 0201088 SMA earthing set negative ESHV-N-NR Compatible to Sunny Boy and SMC with transformer 2 years 0201095 SMA fuse kit 12 A (SIBA, 900 V) String fuse kit for SMC 9000/10000/11000TL 2 years

0201060 SMA Piggy Back RS485 interface SB Data transmission by cable RS485 from Sunny Boy to WebBox Up to 50 inverters Add-on kit A 2 years 0201089 SMA Power Balancer cable PBL-YCABLE-10

Inverter communication in a network Connection to SMA inverter Warranty Art. No. Model Function Inverter communication in a network Connection to SMA inverter Warranty Art. No. Model Function Inverter communication in a network Connection to SMA inverter Warranty

0201061 SMA Piggy Back RS485 interface NG Data transmission by cable RS485 from Sunny Boy New Generation to WebBox Up to 50 inverters Add-on kit A 2 years

0201091 SMA Piggy Back RS485 interface SMC Data transmission by cable RS485 from Sunny Mini Central to WebBox Up to 50 inverters Add-on kit A 2 years

0201087 SMA earthing set positive ESHV-P-NR Compatible to Sunny Boy and SMC with transformer 2 years

72

0201090 SMA Power Balancer add-on kit PBL-SMC-10NR Pluggable to Add-on kit to connector SMC 9000/10000/11000- system, to TL-10 SMC 6000/7000/8000TL 2 years 0201097 SMA fuse kit 20 A (SIBA, 900 V) String fuse kit for SMC 9000/10000/11000TL 2 years

0201093 0201094 SMA fuse kit 8 A (SIBA, SMA fuse kit 10 A (SIBA, 900 V) 900 V) String fuse kit for SMC 9000/10000/11000TL 2 years 0201098 SMA wind sensor incl. 3 m cable For the connection to SMA SensorBox 2 years String fuse kit for SMC 9000/10000/11000TL 2 years 0201101 SMA Piggy Back Bluetooth Transmission Bluetooth from Sunny Boy and SMC to Sunny Beam 2 years

2 years 0201096 SMA fuse kit 16 A (SIBA, 900 V) String fuse kit for SMC 9000/10000/11000TL 2 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

73

Batteries
Batteries must adjust exactly to your requirements: We stock low-maintenance and maintenance-free lead batteries of low, medium and high capacity, resistant gel batteries, block batteries for stationary solar systems and many other items.

HOPPECKE

75

...................................................................................................................................................................
BATTERIES

...................................................................................................................................................................

Low-maintenance

Hoppecke Solar batteries for all applications


Hoppecke power.com The all-rounders
The longevity, the cycle stability and the high operational reliability make the batteries of the Hoppecke power.com series true all-rounders for solar installations with small to medium loads. The use of an electrolyte xed in eece results in optimum load acceptance and very good corrosion resistance. The casing from shock-resistant plastics and the battery lid with integrated handle-bar lead to easy handling and robustness in daily use.

Hoppecke OpzV solar The maintenancefree

76

Due to their closed gel technology, the Hoppecke OPzV solar batteries enable maintenance-free operation. The excellent cycle stability provides the greatest reliability for the supply of stand-alone systems or consumers away from the grid. In addition, the closed cycle of potential recyclables within a certied recycling system protects the environment.

Hoppecke OPzS solar The most powerful

The benets at a glance


n n n n n n

With their tubular plates, the Hoppecke OPzS solar batteries offer maximum durability and cycle stability. Because they are produced using special grates with higher lead content, both charge acceptance and corrosion life time are optimal. The optional Aqua Gen recombiners can reduce the water losses during operation and minimise the related maintenance requirements.

Highest longevity and cycle stability Best operational reliability Optimum load acceptance Minimal maintenance requirements Easy handling Robust design

With capacities of 52 to 220 Ah, the Hoppecke power.com series provides models for any requirement.

The enclosed Hoppecke power.com lead batteries can be operated horizontally and are maintenance-free. Re-lling of water is unnecessary.

................................................................................................................................................................... ...................................................................................................................................................................
Low-maintenance BATTERIES

Art. No.

0303041

0303042

0303043

0303044

0303045

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke power.com SB 12V 50 12.00 V 52 Ah 62 Ah 229 mm / 177 mm / 230 mm 26.0 kg 2 years 0303046

Hoppecke power.com SB 12V 60 12.00 V 63 Ah 74 Ah 229 mm / 177 mm / 230 mm 26.5 kg 2 years 0303047

Hoppecke power.com SB 12V 80 12.00 V 80 Ah 94 Ah 344 mm / 177 mm / 230 mm 37.5 kg 2 years 0303048

Hoppecke power.com SB 12V 100 12.00 V 95 Ah 111 Ah 344 mm / 177 mm / 230 mm 38.0 kg 2 years 0303049

Hoppecke power.com SB 12V 110 12.00 V 111 Ah 130 Ah 498 mm / 177 mm / 230 mm 52.0 kg 2 years 0303050

77

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke power.com SB 12V 130 12.00 V 129 Ah 151 Ah 498 mm / 177 mm / 230 mm 52.5 kg 2 years 0303051

Hoppecke power.com SB 12V 140 12.00 V 142 Ah 166 Ah 498 mm / 177 mm / 230 mm 54.5 kg 2 years 0303052

Hoppecke power.com SB 6V 170 6.00 V 170 Ah 194 Ah 242 mm / 170 mm / 275 mm 32.0 kg 2 years 0303053

Hoppecke power.com SB 6V 220 6.00 V 220 Ah 253 Ah 308 mm / 170 mm / 275 mm 41.0 kg 2 years 0303054

Hoppecke 4 OPzS 200 solar 1.85 V 200 Ah 280 Ah 105 mm / 208 mm / 420 mm 17.2 kg 2 years 0303055

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke 5 OPzS 250 solar 1.85 V 250 Ah 350 Ah 126 mm / 208 mm / 420 mm 20.8 kg 2 years 0303056

Hoppecke 6 OPzS 300 solar 1.85 V 300 Ah 420 Ah 147 mm / 208 mm / 420 mm 24.3 kg 2 years 0303057

Hoppecke 5 OPzS 350 solar 1.85 V 350 Ah 520 Ah 126 mm / 208 mm / 535 mm 26.9 kg 2 years 0303058

Hoppecke 6 OPzS 420 solar 1.85 V 420 Ah 620 Ah 147 mm / 208 mm / 535 mm 31.5 kg 2 years 0303059

Hoppecke 7 OPzS 490 solar 1.85 V 490 Ah 730 Ah 168 mm / 208 mm / 535 mm 36.1 kg 2 years 0303060

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Continued on next page

Hoppecke 6 OPzS 600 solar 1.85 V 600 Ah 910 Ah 215 mm / 193 mm / 710 mm 44.8 kg 2 years

Hoppecke 8 OPzS 800 solar 1.85 V 800 Ah 1220 Ah 215 mm / 235 mm / 710 mm 61.3 kg 2 years

Hoppecke 10 OPzS 1000 solar 1.85 V 1000 Ah 1520 Ah 215 mm / 277 mm / 710 mm 74.6 kg 2 years

Hoppecke 12 OPzS 1200 solar 1.85 V 1200 Ah 1820 Ah 215 mm / 277 mm / 710 mm 88.0 kg 2 years

Hoppecke 12 OPzS 1500 solar 1.85 V 1500 Ah 2170 Ah 215 mm / 277 mm / 855 mm 114.3 kg 2 years

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
BATTERIES

...................................................................................................................................................................

Low-maintenance

Art. No.

0303061

0303062

0303063

0303066

0303067

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke 16 OPzS 2000 solar 1.85 V 2000 Ah 2900 Ah 215 mm / 400 mm / 815 mm 151.5 kg 2 years 0303068

Hoppecke 20 OPzS 2500 solar 1.85 V 2500 Ah 3610 Ah 215 mm / 490 mm / 815 mm 193.0 kg 2 years 0303069

Hoppecke 24 OPzS 3000 solar 1.85 V 3000 Ah 4340 Ah 215 mm / 580 mm / 815 mm 246.0 kg 2 years 0303070

Hoppecke 4 OPzV solar. power 250 1.85 V 206 Ah 247 Ah 105 mm / 208 mm / 420 mm 20.0 kg 2 years

Hoppecke 5 OPzV solar. power 310 1.85 V 258 Ah 309 Ah 126 mm / 208 mm / 420 mm 24.0 kg 2 years

0303071

78

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke 6 OPzV solar.power 370 1.85 V 309 Ah 371 Ah 147 mm / 208 mm / 420 mm 28.0 kg 2 years 0303072

Hoppecke 5 OPzV solar.power 420 1.85 V 361 Ah 412 Ah 126 mm / 208 mm / 535 mm 31.0 kg 2 years 0303073

Hoppecke 6 OPzV solar.power 520 1.85 V 433 Ah 515 Ah 147 mm / 208 mm / 535 mm 37.0 kg 2 years 0303074

Hoppecke 7 OPzV solar.power 620 1.85 V 505 Ah 618 Ah 168 mm / 208 mm / 535 mm 42.0 kg 2 years 0303075

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty * Art. No.

Hoppecke 6 OPzV solar.power 750 1.85 V 618 Ah 742 Ah 147 mm / 208 mm / 710 mm 50.0 kg 2 years 0303076

Hoppecke 8 OPzV solar.power 1000 1.85 V 824 Ah 989 Ah 215 mm / 193 mm / 710 mm 68.0 kg 2 years 0303077

Hoppecke 10 OPzV solar. power 1250 1.85 V 1030 Ah 1236 Ah 215 mm / 235 mm / 710 mm 82.0 kg 2 years 0303078

Hoppecke 12 OPzV solar. power 1500 1.85 V 1236 Ah 1442 Ah 215 mm / 277 mm / 710 mm 97.0 kg 2 years 0303079

Model Voltage Capacity (10 h) Capacity (100 h) Dimensions (L / W / H) Weight Warranty *

Hoppecke 12 OPzV solar. power 1700 1.85 V 1515 Ah 1717 Ah 215 mm / 277 mm / 855 mm 120.0 kg 2 years

Hoppecke 16 OPzV solar. power 2300 1.85 V 2020 Ah 2323 Ah 215 mm / 400 mm / 815 mm 165.0 kg 2 years

Hoppecke 20 OPzV solar. power 2900 1.85 V 2525 Ah 2929 Ah 215 mm / 490 mm / 815 mm 200.0 kg 2 years

Hoppecke 24 OPzV solar. power 3500 1.85 V 3030 Ah 3535 Ah 215 mm / 580 mm / 815 mm 240.0 kg 2 years

* - Provided the batteries have been correctly installed Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

................................................................................................................................................................... ...................................................................................................................................................................
Low-maintenance BATTERIES

Accessories Art. No. 0303064 0303065

Model Hoppecke Aqua Gen Premium Top H, <340 Ah Hoppecke Aqua Gen Premium Top V, >340 Ah

Description Recombiner for all OPzS batteries <340 Ah Recombiner for all OPzS batteries >340 Ah

79

Hoppecke OPzS solar batteries should always be used in combination with the optional Aqua Gen recombiners to keep the maintenance requirements to a minimum.

The series Hoppecke OPzV solar is based on a closed gel technology, which makes the batteries maintenance-free and safe.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Controllers
A high-quality charge controller secures a long service life of the battery and provides correct power supply. We offer state-of-the-art development, components of the latest generation and extensive functionality and performance also in solar charge controllers.

MORNINGSTAR

81

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

Second ProStar generation


The ProStar is a microprocessor-controlled solar controller that features numerous additional functions, besides exhaustive-discharge and overcharge protection. For example, it switches over from 12 to 24 V depending on application. The ProStar is available for 15 or 30 A and for 12, 24 and 48 V. The battery type (gel, dry-cell or wet-cell battery) can be set by means of a contact. Both the battery connection and the module connection are protected against reverse polarity. As an option, the ProStar is available with a liquidcrystal display (LCD) and a master switch. The master switch allows the solar modules and the load to be connected and disconnected. The 4-step charging algorithm ensures gentle recharging of the battery even at low charging currents.

Special features of the ProStar


n

n n

82

n n n

Digital measuring instrument; very precise voltage and current reading, low power consumption (22 mA) On/Off switch Indication of ve different protection functions and isolation states Self-diagnosis (self-test) Positive grounding (optional) Temperature sensor

Morningstar, as the manufacturer, grants 5 years warranty on the ProStar series.

COMPENSATION

TENSION

NIGHTTIME

FULL CHARGE

PULSE WIDTHMODULATED CONTROL

TRICKLE CHARGING NIGHTTIME

TIME

The second generation of ProStar sets new standards for reliability and self-diagnosis. Available models: 15 or 30 A, 12, 24 or 48 V.

Four charging steps for prolonging the battery service life.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400142

0400143

0400144

0400151

0400161

Model Module current Load current System power rating

ProStar-15

ProStar-15 with LCD 15 A 15 A 250 W (12 V) / 500 W (24 V) Automatic 12 or 24 V 50 V 8V 40 mV 60 mV Yes 22 mA at 12 V, 25 mA at 24 V Pulse-width modulation, constant voltage All 4 inputs Yes, 11.4 V at 12 V, 22.8 V at 24 V -40 to +60 C Connection terminals for exiblele leads up to 10 mm 153 mm / 105 mm / 55 mm 340 g 5 years

15 A 15 A 250 W (12 V) / 500 W (24 V) System voltage Automatic 12 or 24 V Max. module voltage 50 V Min. operating voltage 8V Accuracy at 12 V 40 mV Accuracy at 24 V 60 mV Accuracy at 48 V Option for paraller connection Yes Power consumption 22 mA at 12 V, 25 mA at 24 V Charging alogorithm Pulse-width modulation, constant voltage Reverse-polarity protection All 4 inputs Exhaustive-discharge protecYes, 11.4 V at 12 V, tion 22.8 V at 24 V Operating temperature -40 to +60 C Connection Connection terminals for exiblele leads up to 10 mm Dimensions (W / H / D) 153 mm / 105 mm / 55 mm Weight 340 g Warranty 5 years

ProStar-15 48V with LCD 15 A 15 A 1000 W 48 V 100 V 15 V 80 mV Yes 28 mA Pulse-width modulation, constant voltage All 4 inputs Yes, 45.6 V at 48 V -40 to +60 C Connection terminals for exiblele leads up to 10 mm 153 mm / 105 mm / 55 mm 340 g 5 years

ProStar-30 30 A 30 A 500 W (12 V) / 1000 W (24 V) Automatic 12 or 24 V 50 V 8V 40 mV 60 mV Yes 22 mA at 12 V, 25 mA at 24 V Pulse-width modulation, constant voltage All 4 inputs Yes, 11.4 V at 12 V, 22.8 V at 24 V -40 to +60 C Connection terminals for exiblele leads up to 10 mm 153 mm / 105 mm / 55 mm 340 g 5 years

ProStar-30 with LCD 30 A 30 A 500 W (12 V) / 1000 W (24 V) Automatic 12 or 24 V 50 V 8V 40 mV 60 mV Yes 22 mA at 12 V, 25 mA at 24 V Pulse-width modulation, constant voltage All 4 inputs Yes, 11.4 V at 12 V, 22.8 V at 24 V -40 to +60 C Connection terminals for exiblele leads up to 10 mm 153 mm / 105 mm / 55 mm 340 g 5 years

83

Accessories Art. No.

0400140

Model Description Function Mounting Ambient temperature Power consumption

RTS for TriStar and ProStar Remote temperature sensor for temperature-compensated charging Measurement of battery temperature Directly on battery, 10 m cable -

Dimensions of the ProStar (all information in mm).

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

SHS series for home solar systems of up to 170 W


The familiar quality and reliability of Morningstar are now also available in the form of a low-cost solar controller. The SHS solar controller is ideal for small installations up to 170 W. mizing damage as the result of moisture or nesting insects. Simple application The SHS solar controller functions fully automatically and requires no calibration or user settings. Information indication LEDs indicate status information such as battery charge state. Automatic load disconnection Automatic load disconnection in the event of undervoltage and full recharging prolong the service life of the battery. The SHS maximizes solar energy supply to the battery.

Advantages of the SHS


n

84
n

Electronic protection The SHS solar controller features internal electronic fuses that do not need to be exchanged. Any connection faults when installing do not damage the controller. Protection against moisture The electronic circuitry of the SHS solar controller features a moisture-impervious coating, thus mini-

Solar module

SHS solar controller

Battery

Load

Two versions of the low-cost SHS are available: The SHS 6 for 100 W and 6 A module and load current and the SHS 10 for 170 W and 10 A.

Simple schematic showing the use of an SHS solar controller.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400121

0400122

Model Module current Load current System power rating System voltage Control value Exhaustive-discharge protection / cut-out value Restart value Charging mode Suitable battery type Electronic protection features Connection Operating temperature Relative humidity Casing Dimensions (W / H / D) Weight Warranty Norms

SHS-6 6A 6A 100 W 12 V 14.3 V Yes, 11.5 V 12.6 V Pulse-width modulation, 4 phases Lead-cell battery Short-circuit and overcurrent, reverse leakage current during nighttime, overvoltage limitation for load protection, lightning strike protection Connection terminals for cable sizes up to 4 mm, corrosionprotected -25 to +50 C 100 % non condensing Plastic, IP22 161 mm / 66 mm / 36 mm 113 g 2 years CE mark, Worldbank

SHS-10 10 A 10 A 170 W 12 V 14.3 V Yes, 11.5 V 12.6 V Pulse-width modulation, 4 phases Lead-cell battery Short-circuit and overcurrent, reverse leakage current during nighttime, overvoltage limitation for load protection, lightning strike protection Connection terminals for cable sizes up to 4 mm, corrosionprotected -25 to +50 C 100 % non condensing Plastic, IP22 161 mm / 66 mm / 36 mm 113 g 2 years CE mark, Worldbank

85

SOLAR CONTROLLER

SH S

TM

SOLAR CONTROLLER

SH S

TM

SOLAR

BATTER Y

LOAD

Green ON when solar cell charges battery


4 3 2 1 6 5

Green ON at high battery charge level Amber ON at moderate battery charge level Red FLASHING at low battery charge level Red ON when load is disconnected Green ON, then Amber ON, then Red ON Green ON Amber ON Red ON on commissioning

1 2 3 4

Negative pole of battery Positive pole of battery Negative pole of solar module Positive pole of solar module Negative pole of load Positive pole of load

all ON error message

5 6

Colour coding of the LED indicators and how to interpret the various indications.

Connections and terminals of the SHS and installation sequence.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

Morningstar SunGuard and SunKeeper The small and inexpensive charge controllers
SunGuard SG-4
The SunGuard SG-4 is one of the smallest, most modern and most economic charge controllers. It is impressive due to low costs, absolutely outstanding reliability, pulse width modulated (PWM) battery charging and consistent high quality. The SunKeeper is available in 6 A and 12 A versions. Both are operated using 12 V DC. As the charge controller has extremely efcient electronics, it also withstands very high temperatures of up to 70C. Both the SK-6 as well as the SK-12 devices are certied for Hazard Category 1, Zone 2 locations. This even makes possible the operation of the charge controller for oil and gas applications.

SunKeeper SK-6 and SunKeeper SK-12

Features
n n

86

n n n n n n

ISO 9002 quality program 100 % electronic circuitry Series connection Genuine pulse modulation from 0 to 100 % Temperature compensation 25 % rated overload protection No load reduction required Lightning protection

Features
n n

n n n n

High reliability Classied for outdoor applications without another case Longer battery service life Classied for applications at hazardous locations Status display using 2 LEDs Simple installation

The SunGuard SG-4 is one of the smallest charge controllers in the world and is impressive due to its efcient pulse width modulation.

The SunKeeper SK-6 and the SunKeeper SK-12 can be directly screwed into the connection sockets of solar modules.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400311

0400250

0400249

Model Load current System voltage Max. voltage Min. operating voltage Accuracy Option for paraller connection Power consumption Temperature compensation Charging mode Connection Reverse-polarity protection Operating temperature Casing Dimensions (W / H / D) Weight Warranty Norms

SunGuard SG-4 4.25 A 12 V 30 V 0V 60 mV No 6 mA -28 mV/C Pulse-width modulation PWM Weatherproof Hypalon connection cables; cables each 1.3 to 1.8 mm -40 to +85 C Shockproof ABS plastic case 64 mm / 51 mm / 38 mm 90 g 5 years CE mark

SunKeeper SK-6 6.00 A 12 V 30 V 0V No 7 mA -30 mV/C Pulse-width modulation PWM PG13.5 / M20 / 0.5 inch, cable 2.0 mm each Integrated -40 to +70 C Plastic case, UV-resistant 99 mm / 51 mm / 13 mm 110 g 5 years CE mark

SunKeeper SK-12 12.00 A 12 V 30 V 0V No 7 mA -30 mV/C Pulse-width modulation PWM PG13.5 / M20 / 0.5 inch, cable 2.0 mm each Integrated -40 to +70 C Plastic case, UV-resistant 99 mm / 51 mm / 13 mm 110 g 5 years CE mark

87

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

SunLight solar lighting controller The solution for automatic light control
New technology
The advanced SunLight lighting controller of Morningstar is the solution for automatic light control. It connects the SunSaver with an extremely reliable microcontroller for precise light control. In addition to its technical features, the SunLight convinces with its compact casing and the user-friendly user interface.

Four versions

Depending on application and connected battery, the Morningstar SunLight is available in four different versions. While the technical features of the devices are identical, you will have to decide whether the SunLight will be connected to a 12 V or 24 V battery and whether it will be operated with a rated current of 10 A or 20 A.

Operation
88

By means of a digital rotary switch, one of ten lighting programmes can be selected. The programmes have a time precision of two seconds. Use the test button to initiate a ve-minute test of the lighting manually. However, this option is limited to three times in subsidiary control operation.

Features in brief
n n n n n n

High precision through digital technology Fully automatic operation Ten different programmes Manual testing possible Protection through overload subsidiary control Detection of day and night by means of the solar generator Temperature compensation

The SunLight solar lighting controller: Clever technology in a small casing

Pre-set light control: Practical and intelligent

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400261

0400281

0400271

0400291

Model Rated current System voltage Control value (Dry battery / Wet battery) Exhaustive-discharge protection Restart voltage Temperature compensation Power consumption Connection Operating temperature Casing Dimensions (W / H / D) Weight Warranty

Morningstar SunLight SL-10L- Morningstar SunLight SL-20L- Morningstar SunLight SL-10L- Morningstar SunLight SL-20L12V 12V 24V 24V 10 A 20 A 10 A 20 A 12 V 12 V 24 V 24 V 14.1 V / 14.4 V 14.1 V / 14.4 V 28.2 V / 28.8 V 28.2 V / 28.8 V 11.7 V 12.8 V -27 mV/C 8 mA Connection terminals, up to 5.2 mm -40 to +85 C Anodized aluminium 168 mm / 55 mm / 34 mm 260 g 5 years 11.7 V 12.8 V -27 mV/C 8 mA Connection terminals, up to 5.2 mm -40 to +85 C Anodized aluminium 168 mm / 55 mm / 34 mm 260 g 5 years 23.4 V 25.6 V -54 mV/C 9 mA Connection terminals, up to 5.2 mm -40 to +85 C Anodized aluminium 168 mm / 55 mm / 34 mm 260 g 5 years 23.4 V 25.6 V -54 mV/C 9 mA Connection terminals, up to 5.2 mm -40 to +85 C Anodized aluminium 168 mm / 55 mm / 34 mm 260 g 5 years

89

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

SunSaver Compact and watertight


SunSaver technology offers excellent reliability, pulse width-modulated (PWM) battery charging and a high quality level. Seven different versions of the compact solar controller are available for 6.5, 10 or 20 A solar module current, for 12 or 24 V battery systems and with or without exhaustive-discharge protection (LVD). The SunSaver features the same 4-step charging algorithm as the ProStar Series. The SunSaver is suitable specically for smaller applications and can be used under the most stringent conditions owing to the completely encapsulated housing. It is absolutely watertight and is consequently virtually predestined for the use in the open air, on board of ships or in damp rooms.

Long battery service life thanks to temperature sensor

90

A temperature sensor incorporated in the casing permits the SunSaver to allow for the various end-ofcharge voltages of the battery, consequently considerably prolonging its service life. Jumpers are used to set the battery type (wet-cell or dry-cell batteries). Morningstar, as manufacturer, grants 5 years warranty on the SunSaver series.

Model designation SS-6 SS-6L SS-10 SS-10L SS-10L-24V SS-20L SS-20L-24V

Solar rating (A)


0 10 20 0

Load rating (A)


10 20

LVD

12V 24V

Reliable solar controllers with a long service life for leisure and industrial applications. Seven models are available for selection: 12 or 24 V, 6, 10 or 20 A, with or without exhaustive-discharge protection. The connection terminals comply with the Marine Standard, and the casing is fully encapsulated and anodized.

SunSaver selection table.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400171

0400181

0400191

0400211

Model Module current Load current System power rating System voltage Max. module voltage Min. operating voltage Accuracy Option for paraller connection Power consumption Typical voltage drop, photovoltaic/battery Typical voltage drop, battery/load Connection Reverse-polarity protection Exhaustive-discharge protection Operating temperature Casing Dimensions (W / H / D) Weight Warranty Art. No.

SS-6 6.5 A 10 A 100 W 12 V 30 V 6V 12 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs No -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years 0400231

SS-6L 6.5 A 6A 100 W 12 V 30 V 6V 12 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs Yes, 11.5 V -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years 0400241

SS-10 10.0 A 10 A 170 W 12 V 30 V 6V 12 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs No -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years 0400251

SS-10L 10.0 A 10 A 170 W 12 V 30 V 6V 12 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs Yes, 11.5 V -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years 0400617

91

Model Module current Load current System power rating System voltage Max. module voltage Min. operating voltage Accuracy Option for paraller connection Power consumption Typical voltage drop, photovoltaic/battery Typical voltage drop, battery/load Connection Reverse-polarity protection Exhaustive-discharge protection Operating temperature Casing Dimensions (W / H / D) Weight Warranty

SS-10L 24 V 10.0 A 10 A 340 W 24 V 60 V 6V 55 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs Yes, 23 V -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years

SS-20L 20.0 A 20 A 340 W 12 V 30 V 6V 12 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs Yes, 11.5 V -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years

SS-20L 24 V 20.0 A 20 A 680 W 24 V 60 V 6V 55 mV Yes 6 - 10 mA 0.4 V 0.300 V Connection terminals, up to 5.2 mm All 3 inputs Yes, 23 V -40 to +85 C Aluminium, IP65 152 mm / 55 mm / 34 mm 230 g 5 years

SS-MPPT-15L 15.0 A 15 A 200 W (12 V) / 400 W (24 V) 12 / 24 V 75 V 7V Yes 35 mA 0.125 V Connection terminals, up to 16 mm All 3 inputs Yes, 23 V -40 to +60 C Aluminium, IP65 169 mm / 64 mm / 73 mm 600 g 5 years

152 140

55

25

34

13

80

4 mounting holes, 5

Dimensions of the SunSaver series (all information in mm).

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

4.6

2.3

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Solar Controllers

Morningstar SunSaver Duo The charge controller for two batteries


The SunSaver Duo is a charge controller with pulse width modulation. It charges two batteries simultaneously. This system is ideal for motorhomes and boats as the "onboard battery" and the "engine battery" for example can be loaded using the same photovoltaic system. The priorities of the batteries and many other parameters can be selected and adjusted by the user according to the respective requirements. All settings are made using the separate control panel. It has a backlit display which shows the current status of the photovoltaic system.

Simple and clean installation

The SunSaver Duo is installed in the vicinity of the batteries. The controller is connected to the display instrument using a cable included in the standard delivery. The display instrument can either be xed to the wall using a bracket or recessed in a cut-out for example in the wall or in the dashboard.

The benets at a glance


n n n

92

More efciency

n n n n n

As two batteries can be charged using the same system, a second system for energy generation is not needed. This saves not only costs but also space and makes the generation of solar energy much more efcient.

Charging of two batteries Provision of information about the system status Low costs Simple installation Longer battery service life Comprehensive electronic safety devices High reliability Remote display included in the package contents

The SunSaver Duo also has an LCD display for checking the charge status of the batteries.

The SunSaver Duo is suitable for simultaneously charging both the onboard as well as the starter battery.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Controllers CONTROLLERS

Art. No.

0400615

Model Load current System voltage Max. voltage Min. operating voltage Charging mode Battery charging priority Power consumption (Controller / Remote display) Control value Exhaustive-discharge protection Overcharge protection Reverse-polarity protection Temperature compensation Operating temperature (Controller / Remote display) Casing Dimensions controller (W / H / D) Dimensions remote display (W / H / D) Weight (Controller / Remote display) Warranty Norms

SunSaver Duo SSD-25RM 25 A 12 V 30 V 1V Pulse-width modulation PWM 90/10 % or 50/50 % 6 - 10 mA / 6 - 15 mA 14.1 - 14.4 V 13.7 V 14.8 V Yes -30 mV/C -40 to +45 C / -20 to +60 C Anodized aluminium 170 mm / 56 mm / 41 mm 97 mm / 97 mm / 31 mm 340 g / 135 g 5 years CE mark

93

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROLLERS

...................................................................................................................................................................

Universal Controllers

TriStar One unit, three functions


The TriStar controller from Morningstar is a 3-function controller for the reliable charging of batteries, load control and bypass control. It operates in one of these operating modes. Two or more controllers can be used for simultaneous usage of several functions. The TriStar is available for 45 and 60 A at 12 to 48 V DC voltage for solar installations up to 4 kW. Optionally, a display is available for the TriStar. The controller is designed both for home solar installations and for professional applications.

Battery sensor and temperature sensor

Connecting battery sensor cables and an optional remote temperature sensor enhances control accuracy. A pulse width-modulated primary current charge with constant voltage prolongs the battery service life.

RS-232 interface

94

The TriStar features an RS-232 interface for conguration, data acquisition, remote monitoring and remote control via PC. It is fully protected against reverse polarity, short circuit, overcurrent and overvoltage.

The TriStar 60 with incorporated display (option) the large heat sink allows operation at full capacity up to an ambient temperature of 45 C.

Brief description of the three functions of the TriStar.

................................................................................................................................................................... ...................................................................................................................................................................
Universal Controllers CONTROLLERS

Art. No.

0400131

0400132

0400621

0400622

Model Solar, load or bypass current System voltage Accuracy Min. operating voltage Max. solar voltage (Uoc) Power consumption Electronic protection features

Connection

Ambient temperature Relative humidity Casing Dimensions (W / H / D) Weight Warranty Norms Accessories Art. No.

TriStar TS-45 MPPT 45 A 12 - 48 V < 0.1 % 50 mV (12/24 V) / < 0.1 % 100 mV (48 V) 8V 150 V 4W Overload, short-circuit, high voltage, temperature, lightning strike, transient surge voltages, countercurrent (night) Connection terminals for Connection terminals for Connection terminals for cable sizes up to 35 mm; pre- cable sizes up to 35 mm; pre- cable sizes up to 35 mm; prepunched cable lead-througs punched cable lead-througs punched cable lead-througs 2.5 / 3.2 cm 2.5 / 3.2 cm 2.5 / 3.2 cm -40 to +45 C -40 to +45 C -40 to +45 C 100 % non condensing 100 % non condensing 100 % non condensing For use in enclosed spaces For use in enclosed spaces Type 1 (indoors and ventilated), IP20 12.7 cm / 26 cm / 7.1 cm 12.7 cm / 26 cm / 7.1 cm 29.1 cm / 13 cm / 14.2 cm 1.6 kg 1.6 kg 4.2 kg 5 years 5 years 5 years CE, UL CE, UL CE, UL

TriStar TS-45 45 A 12 - 48 V < 0.1 % 50 mV (12/24 V) / < 0.1 % 100 mV (48 V) 9V 125 V 4W Reverse-polarity, short-circuit and overcurrent, reverse leakage current, lightning strike

TriStar TS-60 60 A 12 - 48 V < 0.1 % 50 mV (12/24 V) / < 0.1 % 100 mV (48 V) 9V 125 V 4W Reverse-polarity, short-circuit and overcurrent, reverse leakage current, lightning strike

TriStar TS-60 MPPT 60 A 12 - 48 V < 0.1 % 50 mV (12/24 V) / < 0.1 % 100 mV (48 V) 8V 150 V 4W Overload, short-circuit, high voltage, temperature, lightning strike, transient surge voltages, countercurrent (night) Connection terminals for cable sizes up to 35 mm; prepunched cable lead-througs 2.5 / 3.2 cm -40 to +45 C 100 % non condensing Type 1 (indoors and ventilated), IP20 29.1 cm / 13 cm / 14.2 cm 4.2 kg 5 years CE, UL

95

0400135

0400136

0400140

Model Description Function Mounting Ambient temperature Power consumption

TriStar Meter 2 x 16 display for direct attachment to TriStar Display of system and controller information, data acquisition, bar charts In place of front panel on controller -40 to +60 C 7.5 mA

TriStar Remotemeter 2 x 16 display for spatially separate display Display of system and controller information, data acquisition, bar charts Built-in model, including 30 m cable -40 to +60 C 7.5 mA

RTS for TriStar and ProStar Remote temperature sensor for temperature-compensated charging Measurement of battery temperature Directly on battery, 10 m cable -

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Stand-alone Inverters
Leading stand-alone inverters of our range safeguard maximum energy yields be it mini-inverters, string inverters or backup inverters with maximum efciency.

KACO SMA MORNINGSTAR

97

...................................................................................................................................................................
STAND-ALONE INVERTERS

...................................................................................................................................................................

230 V, 50 Hz

Kaco stand-alone inverters The new sine-wave stand-alone inverters


Independent energy supply
The new sine-wave inverters are ideally suited for use in areas where no or only a very unreliable public power supply is available. By converting the directcurrent voltage of a battery (e.g. 12 V, 24 V or 48 V) to alternating-current voltage (230 V / 50 Hz) these devices provide independent power supply anywhere.

Pure sine-wave voltage

The pure sine-wave voltage generated by Kaco sinewave inverters can also power sensitive consumers such as energy-saving lamps, TVs, refrigerators or computers. Solutions with "modied sine-wave voltage" (trapezoidal or triangular wave-form), or square-wave voltage may damage sensitive consumers.

Inexpensive alternative

98

The alternating-current voltage generated by the Kaco inverters can power commercially available 230 V consumers of any kind. In most cases, this is signicantly cheaper than more expensive and often less efcient 12 V devices with high energy consumption.

The benets at a glance


n n n n n

n n

Pure-sine-wave High peak efciency Low cable losses Extreme high peak power Nominal power at high ambient temperature possible Coated pcb Applicable in rough ambient conditions High reliability

Kaco Kl 1000 and Kl 2000 The new sine-wave stand-alone inverters with integrated display

The Kaco Kl 250 The inexpensive stand-alone inverter for up to 250 W

................................................................................................................................................................... ...................................................................................................................................................................
230 V, 50 Hz STAND-ALONE INVERTERS

Art. No.

0600367

0600370

0600368

0600371

0600369

0600372

Model Output voltage Frequency AC continuous output 30 C AC continuous output 30 C (30 / 5 / 0.01 min) Max. current Harmonic distortion Input voltage Max. efciency Battery capacity (recommended) Ambient temperature Protection mode Casing Dimensions (W / H / D) Weight Warranty Norms

Kaco KI 250 - 12 V 230 V 50 Hz 200 W 250 / 360 / 460 W 15 A <3% 12 V 91 % 125.0 Ah -15 to +60 C IP20 Aluminium 130 mm / 88 mm / 216 mm 3.3 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

Kaco KI 250 - 24 V 230 V 50 Hz 200 W 250 / 360 / 460 W 15 A <3% 24 V 91 % 62.5 Ah -15 to +60 C IP20 Aluminium 130 mm / 88 mm / 216 mm 3.3 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

Kaco KI 1000 - 12 V 230 V 50 Hz 800 W 1000 / 1300 / 2200 W 30 A <3% 12 V 93 % 500.0 Ah -15 to +60 C IP20 Aluminium 274 mm / 125 mm / 354 mm 15.0 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

Kaco KI 1000 - 24 V 230 V 50 Hz 800 W 1000 / 1300 / 2200 W 30 A <3% 24 V 93 % 250.0 Ah -15 to +60 C IP20 Aluminium 274 mm / 125 mm / 354 mm 15.0 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

Kaco KI 2000 - 24 V 230 V 50 Hz 1600 W 2000 / 2880 / 4800 W 30 A <3% 24 V 94 % 500.0 Ah -15 to +60 C IP20 Aluminium 274 mm / 125 mm / 454 mm 23.0 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

Kaco KI 2000 - 48 V 230 V 50 Hz 1600 W 2000 / 2880 / 4800 W 30 A <3% 48 V 94 % 250.0 Ah -15 to +60 C IP20 Aluminium 274 mm / 125 mm / 454 mm 23.0 kg 3 years EN60950, EN55014, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN55022, ECE R10

99

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
STAND-ALONE INVERTERS

...................................................................................................................................................................

230 V, 50 Hz

SMA Sunny Island


Off-grid inverters, system managers of stand-alone energy supplies System monitoring

Together with the battery unit, the stand-alone inverter Sunny Island creates a standard AC voltage grid into which all components, from electrical appliances to electricity generators, can be integrated. With this AC coupling and the Sunny Island as its system manager, SMA has developed the technological solution for energy supply in remote areas which are far away from the mains grid, or for emergency power supply in unstable grids. 100 For the rst time, PV systems, wind turbines, diesel generators, hydroelectric or combined heat and power plants can now be coupled on the AC side along with 230 V loads, eliminating the need for expensive DC cabling and providing maximum exibility.

The Sunny Island product range is compatible with all SMA communication products. The monitoring options range from on-site monitoring, right through to visualisation on the Internet.

Expandability

Stand-alone grids with the Sunny Island can be expanded from a single-phase supply to a 3-phase grid with several Sunny Islands. This can be done step by step, according to the increasing energy demand.

SMA Smart Load

Quality electricity

The Sunny Island guarantees stand-alone grids with perfectly sinusoidal voltage, high overload capability, and excellent reliability.

The Smart Load SL 6000 is the perfect addition to any unregulated power generator in an AC-coupled standalone grid. Its unique automatic control allows it to adapt to different power conditions optimally. In the event of an energy surplus, the Sunny Islands slightly increase the frequency, whereupon the Smart Load increases its power consumption. In so doing, it feeds precisely the right amount of energy to a load until balance has been restored in the system.

The Sunny Island as the core of self-sufcient energy supply in the off-grid area.

Since all Sunny Islands are based on an AC coupling, standardised consumers can be used in the entire system.

................................................................................................................................................................... ...................................................................................................................................................................
230 V, 50 Hz STAND-ALONE INVERTERS

Art. No.

0600365

0600366

0600345

0600346

0600348

0600349

Model Output voltage Frequency AC continuous output 25 C / 45 C AC continuous output 25 C (30 / 5 / 1 min) AC rated current Max. power (peak value for 100 ms) Harmonic distortion Power factor Input voltage Input frequency Max. AC input current Max. input power Max. efciency Battery voltage (range) Max. battery charging current Constant charging current Battery capacity Charge control Ambient temperature Protection mode Casing Dimensions (W / H / D) Weight Warranty Norms

SMA SI 2012 202 - 253 V 45 - 65 Hz 2000 / 1400 W

SMA SI 2024 202 - 253 V 45 - 65 Hz 2200 / 1600 W

SMA SI 3324 202 - 253 V 45 - 55 Hz 3300 / 2300 W

SMA SI 4248 202 - 253 V 45 - 55 Hz 4200 / 3400 W

SMA SI 5048 202 - 253 V 45 - 65 Hz 5000 / 4000 W

SMA SL 6000 3 x 0 - 230 V 45 - 65 Hz 3 x 0 - 2000 W

2700 / 3600 / 3600 W 2900 / 3800 / 3800 W 4200 / 4600 / 5000 W 5400 / 6200 / 7000 W 6500 / 7200 / 8400 W 8.7 A 25 A <4% -1 to +1 172.5 - 250 V 40 - 70 Hz 25 A 5.75 kW 93.0 % 12 V (10.2 - 15.6 V) 180 A 150 A 100 - 10000 Ah IUoU with automatic full and equalising charge -25 to +60 C IP54 Aluminium 470 mm / 445 mm / 185 mm 18 kg 5 years CE mark 9.6 A 25 A <4% -1 to +1 172.5 - 250 V 40 - 70 Hz 25 A 5.75 kW 93.6 % 24 V (16.8 - 31.5 V) 90 A 80 A 100 - 10000 Ah IUoU with automatic full and equalising charge -25 to +60 C IP54 Aluminium 470 mm / 445 mm / 185 mm 18 kg 5 years CE mark 14.5 A 100 A <3% -1 to +1 172.5 - 250 V 40 - 60 Hz 56 A 12.8 kW 94.5 % 24 V (21 - 32 V) 140 A 104 A 100 - 6000 Ah IUoU with automatic full and equalising charge -25 to +50 C IP30 Aluminium 390 mm / 590 mm / 245 mm 39 kg 5 years CE mark 18.0 A 100 A <3% -1 to +1 172.5 - 250 V 40 - 60 Hz 56 A 12.8 kW 95.0 % 48 V (41 - 63 V) 100 A 80 A 100 - 6000 Ah IUoU with automatic full and equalising charge -25 to +50 C IP30 Aluminium 390 mm / 590 mm / 245 mm 39 kg 5 years CE mark 21.7 A 100 A <3% -1 to +1 172.5 - 250 V 40 - 70 Hz 56 A 12.8 kW 95.0 % 48 V (41 - 63 V) 120 A 100 A 100 - 10000 Ah IUoU with automatic full and equalising charge -25 to +50 C IP40 Aluminium 467 mm / 612 mm / 235 mm 63 kg 5 years CE mark 3 x 180 - 270 V Short-circuit proof -25 to +50 C IP65 Aluminium 435 mm / 322 mm / 213 mm 14 kg 5 years CE mark

101

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
STAND-ALONE INVERTERS

...................................................................................................................................................................

230 V, 50 Hz

SMA Sunny Backup Set


Solar energy even during power failure
easy-to-install set solution for outputs of 2.2 kW 30 kW of backup power.

The new Sunny Backup Set from SMA now allows home owners to use their own solar system cost-effectively even during a power failure to ensure power supply for key consumers. Supplementing the PV system, this system fully automatically switches to stand-alone power supply within a mere 50 milliseconds in the event of a power failure. Both new and existing PV systems can be tted with the Sunny Backup Set without adverse effect on their efciency. 102

The advantages of the Sunny Backup Set


n n n n

n n

Simple and cost-effective complete system

Due to integration of the PV system, the battery can be kept small and thus remains cost-effective, as it usually only needs to bridge the night hours. The Sunny Backup Set from SMA is provided as a precongured,

n n

Pre-congured set Small and cost-effective Very small switching facility Smaller battery dimensions due to incorporation of the PV system Energy supply and battery charging via the grid PV efciency remains consistently high Automatic switching to backup supply in approximately 50 ms Automatic disconnection unit DIN VDE 0126-1-1 5 years SMA warranty

The new Sunny Backup 2200 is available as a complete SBU Set S package for cost-effective supply in case of power failure.

The Sunny Backup 5000 in the complete package, SBU Set M, L or XL, exibly adjusts to the output.

................................................................................................................................................................... ...................................................................................................................................................................
230 V, 50 Hz STAND-ALONE INVERTERS

Art. No.

0600355

0600356

0600357

0600358

Model Number and type of Sunny Backup (SBU) Output voltage Frequency Nominal input current Nominal output Rated power consumer Rated current consumer Max. backup power (duration / 30 min / 1 min) Rated voltage AGM battery Energy / capacity (C10) AGM battery Battery packs Battery fuse / connection Ambient temperature Relative humidity Protection mode Grid monitoring Casing Compatible inverters Dimensions SBU (W / H / D) Dimensions switching facility AS box (W / H / D) Dimensions AGM battery per pack (W / H / D) Weight (Sunny Backup / AS box / AGM battery) Generator connection Warranty Norms

SMA SBU 2200 Set S 1 x SBU 2200 230 V 50 Hz 20 A 4.6 kW 5.7 kW 25 A 2.2 kW / 2.9 kW / 3.8 kW 12 V / 24 V 3.4 kWh / 142 Ah 2 pc. Included / 4 m -25 to +60 C 0 to 98 %, no condensation IP54 Automatic disconnection unit VDE 0126-1-1 Aluminium All Sunny Boys from May 2005 470 mm / 445 mm / 180 mm 200 mm / 300 mm / 120 mm 498 mm / 230 mm / 177 mm 18 kg / 4.5 kg / 54.5 kg Not possible 5 years CE mark, VDE 0126-1-1

SMA SBU 5000 Set M 1 x SBU 5000 230 V 50 Hz 25 A 5.7 kW 8.0 kW 35 A 5.0 kW / 6.5 kW / 8.4 kW 12 V / 24 V 6.7 kWh / 142 Ah 4 pc. Included / 4 m -25 to +60 C 0 to 98 %, no condensation IP65 Automatic disconnection unit VDE 0126-1-1 Aluminium All Sunny Boys from May 2005 467 mm / 612 mm / 235 mm 600 mm / 600 mm / 210 mm 498 mm / 230 mm / 177 mm 63 kg / 29.0 kg / 54.5 kg Optional (8 kW) 5 years CE mark, VDE 0126-1-1

SMA SBU 5000 Set L 3 x SBU 5000 3 x 230 V / 400 V 50 Hz 3 x 44 A 30.0 kW 44.0 kW 3 x 63 A 15.0 kW / 19.5 kW / 25.2 kW 12 V / 24 V 13.4 kWh / 284 Ah 8 pc. Included / 4 m -25 to +60 C 0 to 98 %, no condensation IP65 Automatic disconnection unit VDE 0126-1-1 Aluminium All Sunny Boys from May 2005 467 mm / 612 mm / 235 mm 600 mm / 760 mm / 210 mm 498 mm / 230 mm / 177 mm 63 kg / 41.0 kg / 54.5 kg Optional (30 kW) 5 years CE mark, VDE 0126-1-1

SMA SBU 5000 Set XL 6 x SBU 5000 3 x 230 V / 400 V 50 Hz 3 x 160 A 110.0 kW 110.0 kW 3 x 160 A 30.0 kW / 39.0 kW / 50.4 kW 12 V / 24 V 2 x 13.4 kWh / 2 x 284 Ah 2 x 8 pc. Included / 4 m -25 to +60 C 0 to 98 %, no condensation IP65 Automatic disconnection unit VDE 0126-1-1 Aluminium All Sunny Boys from May 2005 467 mm / 612 mm / 235 mm 1000 mm / 1600 mm / 300 mm 498 mm / 230 mm / 177 mm 63 kg / 180.0 kg / 54.5 kg Optional (110 kW) 5 years CE mark, VDE 0126-1-1

103

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
STAND-ALONE INVERTERS

...................................................................................................................................................................

12 & 24 V

Morningstar SureSine-300 Stand-alone inverter with pure sine wave


Optimum operation
An alternating voltage comparable to the normal mains supply is produced by the sine wave. On the one hand, this improves the service life of all devices connected to the network; on the other hand, signicantly better performance of the devices is achieved. An outstanding waveform is achieved in the complete input voltage range by the toroidal core transformer.

Absolute reliability

The SureSine-300 is perfectly protected against shortcircuits, overload, too high temperatures and undervoltage by integrated protection mechanisms. Operation of the device is resumed automatically after most errors.

Other benets at a glance


n n

More output
104

The high peak efciency ensures the provision of more solar energy for all connected devices. The heat development is also reduced. The inverter consumes 450 mA under load. If no load is present, the device automatically changes over to standby mode. The energy consumption is then reduced to one tenth and no solar energy is wasted.

No cooling fan, therefore no noises Tropicalised design; the case withstands practically all weather conditions 2 LEDs give the user information about operating status and errors at any time Remote On/Off switch, interruption of alternating current no longer needed DIP switches and the possible connection to a PC enable the conguration of all parameters

SureSine-300 The inverter with pure sine wave

SureSine-300 The connections

................................................................................................................................................................... ...................................................................................................................................................................
12 & 24 V STAND-ALONE INVERTERS

Art. No.

0600341

Model Input voltage Max. DC output Max. input voltage Nominal output Output voltage Frequency Harmonic oscillation Max. efciency Night-time consumption Ambient temperature Relative humidity Protection mode Data communication (optional) Dimensions (L / W / H) Weight Warranty Norms

SureSine-300 12V - 220V 10.0 - 15.5 V 600 W 15.5 V 300 W 220 / 115 V 10 % 50 / 60 Hz 10 % <4% 92 % 25 - 450 mA -40 to +45 C 0 to 100 %, no condensation IP20 RJ-11 213 mm / 152 mm / 105 mm 4.5 kg 2 years CE mark

105

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Control and Measuring Instruments


We produce our own monitoring and measuring instruments and are development leaders in this area. With a simple push of a button you can measure the current-voltage curve using the mobile characteristics analyser TRI-KA. Additionally, we offer our own heat sensors, which can measure the outside as well as the module temperature, in order to improve the measuring results of dataloggers.

TRITEC SOLAR-LOG

107

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Characteristics Analyser

TRI-KA The mobile characteristics analyser: Now even more efcient


Mobile portable measuring instrument
On occasion of the Intersolar 2010 we present the improved version of the TRIKA. The new TRIKA not only identies the current voltage curves of module strings, but also of individual photovoltaic modules. The I-U characteristic curve, output, short-circuit current and open-circuit voltage are recorded by a 16 bit processor. During each measurement the TRI KA adjusts the measuring range and sample rate optimally. The device is easily and intuitively operated using the menus on the colour touch screen. The characteristic curve measured by the TRIKA can be converted to a STC characteristic curve based on the values measured by the sensor TRISEN and displayed. In addition, the STC ideal characteristic curve of the manufacturer can be displayed, due to the integrated module data base. instrument, the TRIKA. The reference cell for the measuring of the irradiation can be either a monocrystalline or a polycrystalline cell.

The evaluation software was also completely overhauled. The TRIKA software can evaluate, manage and store the measured module data on the PC. With a few steps of the guided Wizard, the measured data is saved to the respective customer or system directory. Further measurements of the same system can then be added, sorted by date, and compared with the software.

Evaluation software

108

Advantages in brief
n n n

Wireless sensor

n n n n

Without contact, the wireless sensor TRISEN measures the cell temperature, the angle of inclination and the irradiation at the solar module level. The measured values are wirelessly transferred directly to the main

Mobile portable measuring instrument Wireless sensor Simple menu navigation on colour touch screen Large measuring range: 1.0 1000 V and 0.1 15.0 A Creation of system and maintenance protocols Output comparison for several years Simple identication of errors and faults of PV systems and PV modules

The TRIKA characteristics analyser and the TRISEN irradiation and temperature sensor are easy to operate and provide reliable measurements.

With the evaluation software the individual strings are evaluated and combined to individual installations. Measurement reports from single strings, single modules and from the entire systems can be printed.

................................................................................................................................................................... ...................................................................................................................................................................
Characteristics Analyser CONTROL AND MEASURING INSTRUMENTS

Art. No.

0802201

Model Included in delivery

TRI-KA complete set 1 TRIKA, 1 TRISEN, 1 rugged case with rubber foam padding, TRIKA measurement cable sets (MC3, MC4, Huber+Suhner, Tyco, SunClix and without connectors), 1 TRISEN mounting, 1 USB SD/SDHC card reader, 2 power supply units (chargeable), operating instructions, CD (PC user software with user guide)

Specications

TRI-KA I/U characteristic curve, short-circuit current, open-circuit voltage, MPP current, MPP voltage Calculated values STC values (short-circuit current, open-circuit voltage, MPP current, MPP voltage), ll factor, MPP output, ideal characteristic curve of module manufacturer Voltage measuring range 1.0 - 1000 V (< 1 %) Current measuring range 0.1 - 15.0 A (< 1 %) Temperature measuring range Irradiation measuring range Measuring connection Measuring cable Characteristic curve measuring 15 - 30 seconds duration Save slots for measured curves Depending on size of SD memory card (> 1000 measured curves with 1 GB) Reference cells Display 3.2 inch colour LCD touch screen (240 x 320 pixels, RGB) Power supply Lithium polymer accumulator, run-time app. 6 hours Auto power-off Adjustable (1 - 15 minutes) Interface 2 measuring cables to PV string, wireless connection to TRISEN, SD/SDHC memory card for PC Ambient temperature 0 to +50 C Protection mode IP20 Insulation Protection class II Measuring category CAT II 1000 V, CAT III 600 V Dimensions (L / W / H) 210 mm / 105 mm / 41 mm Weight 500 g Warranty 2 years Norms IEC/EN 61010-1, CE mark Spare parts Art. No. 0801101 0801102 0801103 0801104 0801110 0802202 0802203 0802205 0802206 0802207 0802208 0802209

Model Measuring

TRI-SEN Global irradiation, module temperature, angle of inclination 0 - 100 C (3 % in relation to a black body) 100 - 1200 W/m (5 %) Non-contact measurement 1 x monocrystalline cell, 1 x polycrystalline cell B/W LC display (2-line, 16 characters) Lithium polymer accumulator, run-time app. 6 hours Wireless connection to TRIKA 0 to +70 C IP20 160 mm / 82 mm / 41 mm 200 g 2 years CE mark

109

Model TRI-KA measurement cable replacement set for MC3 TRI-KA measurement cable replacement set for MC4 TRI-KA measurement cable replacement set for Huber+Suhner TRI-KA measurement cable replacement set for Tyco TRI-KA measurement cable replacement set without connector TRI-SEN mounting TRI-KA measurement cable replacement set for SunClix TRI-KA SD/SDHC card reader TRI-KA SD/SDHC memory card TRI-KA user software on CD TRI-KA rugged case, empty TRI-KA chargeable power supply unit

Belongs to Art. No. 0802201 0802201 0802201 0802201 0802201 0802201 0802201 0802201 0802201 0802201 0802201 0802201

System requirements user software: Microsoft Windows XP / Vista / 7; Pentium processor with a minimum of 600 MHz or similar; minimum of 256 MB memory or more; VGA graphics card with at least 16 bit colour depth (High Color) and a resolution of 1024 x 768 pixels; free hard disc memory of at least 500 MB; CD/DVD disc drive; keyboard; mouse; USB interface

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Datalogger

The Solar-Log series The monitoring system for all photovoltaic systems
State-of-the-art technology
n n

The devices of the Solar-Log series provide simple monitoring of solar systems of all types. Due to state-of-theart technology, the operation, analysis and display of all parameters are handled by the web browser. And the web browser is independent of the operating system.

n n n

Status and fault monitoring Completely internet-enabled; sends messages via email and SMS Existing broadband router can also be used S0 output for large displays S0 input for electric meter

Great exibility

Additional features of the Solar-Log 1000


n n

110

The RS485 interface allows the connection and analysis of all current inverters. The Solar-Log series is a manufacturer-independent complete solution, which provides all tools for the professional monitoring and analysis of solar systems.

n n

Features
n n

Graphic display with touch screen for direct operation Datalogger with 2 x RS485 for mixed operation of inverters USB port for simple data transfer Connection of Solar-Log SensorBox for the recording of environmental data Theft protection via detection loop

String monitoring Monitoring of failure and performance of individual inverters

The new Solar-Log500 and Solar-Log1000 are multilingual and can be connected to almost any inverter during installation.

The Solar-LogTM portal offers the perfect display of all data of a photovoltaic system.

................................................................................................................................................................... ...................................................................................................................................................................
Datalogger CONTROL AND MEASURING INSTRUMENTS

Art. No.

0802195

0802196

0802186

0802187

Model Max. number of inverters Software conguration Recommended max. system size Max. cable length Voltage (Supply / Device) Power consumption Ambient temperature Protection mode Casing Display Interface

Solar-Log 200 - for 1 inverter, Solar-Log 200BT - for multi-lingual 1 inverter, Bluetooth, multilingual 1 pc. 1 pc. Flexible Flexible 15 kW 15 kW 1000 m 230 V / 12 V 3W -10 to +50 C IP20 Plastic 1000 m 230 V / 12 V 3W -10 to +50 C IP20 Plastic -

Solar-Log 500 - for up to 10 inverters, multi-lingual 10 pc. Flexible 100 kW

Solar-Log 500BT - for up to 10 inverters, SMA Bluetooth 10 pc. Flexible 100 kW 230 V / 12 V 3W -10 to +50 C IP20 Plastic Two-line text display with status LEDs Ethernet - RJ45 bush 10/100 MBit, 1 x RS485/RS422, max. 24 V DC, max. 5 A continuous current, S0 pulse input/output (acc. to DIN 43864 & 62056), Bluetooth Via web browser and membrane keyboard Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years

1000 m 230 V / 12 V 3W -10 to +50 C IP20 Plastic Two-line text display with status LEDs Ethernet - RJ45 bush Ethernet - RJ45 bush Ethernet - RJ45 bush 10/100 MBit, 1 x RS485/RS422, 10/100 MBit, 1 x RS485/RS422, 10/100 MBit, 1 x RS485/RS422, max. 24 V DC, max. max. 24 V DC, max. max. 24 V DC, max. 5 A continuous current, S0 5 A continuous current, S0 5 A continuous current, S0 pulse input/output (acc. to pulse input/output (acc. to pulse input/output (acc. to DIN 43864 & 62056) DIN 43864 & 62056) DIN 43864 & 62056) Via web browser Via web browser Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years 0802189 Via web browser and membrane keyboard Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years 0802193

Handling Data interpretation Dimensions (L / W / H) Weight Warranty Art. No.

111

Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years 0802188

Model Max. number of inverters Software conguration Recommended max. system size Max. cable length Voltage (Supply / Device) Power consumption Ambient temperature Protection mode Casing Display Interface

Solar-Log 1000 - for up to 100 inverters, Solar-Log 1000BT - for up to multi-lingual 100 inverters, SMA Bluetooth 100 pc. Flexible 1000 kW 1000 m 230 V / 12 V 3W -10 to +50 C IP20 Plastic Graphic display with touch screen Ethernet - RJ45 bush - 10/100 MBit, 1 x RS485/RS422 and 1 x RS485, max. 24 V DC, max. 5 A continuous current, S0 pulse input/output (acc. to DIN 43864 & 62056), alarm contact, USB port (Host), RS232 for modems Via web browser and touch screen display Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years 100 pc. Flexible 1000 kW 230 V / 12 V 3W -10 to +50 C IP20 Plastic Graphic display with touch screen Ethernet - RJ45 bush - 10/100 MBit, 1 x RS485/RS422 and 1 x RS485, max. 24 V DC, max. 5 A continuous current, S0 pulse input/output (acc. to DIN 43864 & 62056), alarm contact, USB port (Host), RS232 for modems, Bluetooth Via web browser and touch screen display Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years

Solar-Log 1000PM - for up to 100 inverters, multi-lingual, Power Manager for SMA, Danfoss and Kaco 100 pc. Flexible 1000 kW 1000 m 230 V / 12 V 3W -10 to +50 C IP20 Plastic Graphic display with touch screen Ethernet - RJ45 bush - 10/100 MBit, 1 x RS485/RS422 and 1 x RS485, max. 24 V DC, max. 5 A continuous current, S0 pulse input/output (acc. to DIN 43864 & 62056), alarm contact, USB port (Host), RS232 for modems, input for ripple control signal Via web browser and touch screen display Integrated web server 225 mm / 285 mm / 40 mm 0.80 kg 5 years

Handling Data interpretation Dimensions (L / W / H) Weight Warranty Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Datalogger

Accessories Art. No. 0802174 0802176 0802179 0802180 0802181 0802182 0802190 0802191 0802192 0802197

Model Description Solar-Log cable set to SMA, 3 m Accessory RS485 cable Solar-Log cable set to Danfoss, 3m Solar-Log 1000 modem pack (home) Solar-Log 1000 modem pack (industry) Solar-Log 1000 mobile communications pack Solar-Log 1000 DIN rail for mobile communications pack Solar-Log SensorBox suitable for 1000 Solar-Log wind sensor, accessory for SensorBox Solar-Log temperature sensor, accessory for SensorBox Solar-Log cable set to Kaco, 3 m Accessory RS485 cable Accessory remote maintenance Accessory remote maintenance Accessory remote maintenance Accessory remote maintenance Measuring irradiation and module temperature Measuring wind speed Measuring ambient temperature Accessory RS485 cable

Belongs to Art. No. 0802186, 0802187, 0802188, 0802189, 0802193, 0802195, 0802196 0802186, 0802187, 0802188, 0802189, 0802193, 0802195, 0802196 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802188, 0802189, 0802193 0802186, 0802187, 0802188, 0802189, 0802193, 0802195, 0802196

112

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

113

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Sensors & Counters

Spektron irradiation sensors


The Spektron 210 and 310 are silicon sensors used for measuring the solar irradiation. The Spektron 210 provides a voltage proportionally to the intensity of the solar irradiation. The Spektron 310 has an integrated amplier. Therefore the sensor signal is amplied and output as a norm signal. The output signal ranges from 0 to 10 V, 0 to 3.125 V, 0 to 150 mV, and 4 to 20 mA at 0 to 1500 W/m.
n n

Sensor for control systems Assessment of evapotranspiration in farming

Ease of use

Range of application
n n n

The Spektron can be connected directly to a voltmeter or a datalogger. The voltage measured by the Spektron 210 can be converted into the unit of irradiation (W/m), using the calibration value imprinted on the sensor.

114

Output and operational check of thermal and photovoltaic solar plants Controlling of shading equipment on buildings Instruction and training

Robust casing

The Spektron can be used irrespective of the weather conditions and under any angle of inclination.

Spektron 210: The 2-core extension cable is UV-resistant. All Spektron devices are calibrated beneath a sun light simulator against a reference sensor, which has been calibrated by the Fraunhofer ISE.

The Spektron 310 can output up to four different norm signals, due to its integrated circuit board. This board has to be powered with 5 to 30 V DC or 12 to 30 V DC.

................................................................................................................................................................... ...................................................................................................................................................................
Sensors & Counters CONTROL AND MEASURING INSTRUMENTS

Art. No.

0802183

0802184

Model Measuring range Sensor type Sensor accuracy Outlet Calibration Design of the sensor Supply voltage Power consumption Casing Connection Mounting Dimensions (L / W / H) Weight Warranty Norms

Spektron 210 0 - 1500 W/m Monocrystalline cell (13 mm / 33 mm) 5 % annual mean Approx. 75 mV at 1000 W/m Sun Simulator Solar Constant 1200 with reference sensor calibrated by the ISE Measuring cell laminated in novaon and EH foil Z-proled aluminium plate, connection encapsulated Cable 3 m, 2 x 1.0 mm 6 mm drill hole to be xed with screws 118 mm / 50 mm / 44 mm 250 g (incl. cable) 2 years CE mark

Spektron 310 0 - 1500 W/m Monocrystalline cell (33 mm / 50 mm) 5 % annual mean 4 - 20 mA or 0 - 10 V or 0 - 3.125 V or 0 - 150 mV Sun Simulator Solar Constant 1200 with reference sensor calibrated by the ISE Measuring cell enclosed in glass 5 - 30 V DC or 12 - 30 V DC Approx. 30 mW Polycarbonate, UV-resistant, with PG screw joint Connection terminals, 1.5 mm Drill holes to be xed with screws and backside slot to be xed with hose clips 150 mm / 80 mm / 60 mm 300 g 2 years CE mark

115

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Sensors & Counters

AC energy meters with pulse output


Electricity meters
a pulse output for data acquisition. If an already installed meter does not have a pulse output, an optical scanning head can be used to read the rotor disk.

The single-phase and three-phase electricity meters can be mounted on a standard DIN rail. They all feature

116

The single-phase electricity meter with mechanical counter.

The 3-phase electricity meter with digital display.

................................................................................................................................................................... ...................................................................................................................................................................
Sensors & Counters CONTROL AND MEASURING INSTRUMENTS

Art. No.

0800351

0800361

Model Measuring-circuit voltage Output Pulse output Frequency Measuring accuracy Rated curr. accuracy class Max. rated current Ambient temperature Connection Mounting Casing Norms Art. No. Model Application Operating voltage Max. sampling rate Current consumption Function check Protection mode Ambient temperature Connection Mounting Casing Dimensions (W / H / D) Norms

Electricity meter single-phase, DIN rail 230 V S0 interface (DIN 43864) 2000 pulses/kWh 50/60 Hz Class I 5A 25 A -20 to +55 C Connection terminals, up to 8 mm 35 mm DIN rail, any position Plastic, gray CE mark 0800381 Optical scanning head For scanning discs or LED counters 5.5 - 30 V DC 3 revolutions/second Max. 5 mA LED IP50 0 to +60 C Cable, 4 m Bonded to viewing panel of power station meter Plastic, black 39 mm / 18 mm / 20 mm CE mark

Electricity meter 3-phase, DIN rail 3 x 230 V S0 interface (DIN 43864) 1000 pulses/kWh 50/60 Hz Class II 5A 63 A -20 to +55 C Connection terminals, up to 25 mm 35 mm DIN rail, any position Plastic, gray CE mark

117

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Sensors & Counters

TRITEC heat sensors


TRITEC surface temperature sensor Pt1000 TRITEC outside temperature sensor Pt1000

The surface temperature sensor Pt1000 is an adhesive foil sensor. It was designed for measurements on surfaces and is primarily used for temperature measurements of solar installations. By installing the surface temperature sensor at the back of a solar module, the module temperature can be measured. The temperature of solar modules is crucial for their output, because the output decreases by 0.43 %/K with increasing temperature. By monitoring the temperature at the solar cells, conclusions can be drawn about the behaviour of the output curve. 118

The outside temperature sensor Pt1000 is integrated in a weather-proof macrolone housing (IP65). Its compact design makes the sensor extremely exible: it can be installed anywhere. The UV-resistant plastic housing is equipped with a cable entry point with PG 9 screw connections. The connection is established by means of a 2-pin terminal block directly at the printed circuit board. The device is supplied with rawlplugs and screws for wall-mounting.

TRITEC surface temperature sensor Pt1000

TRITEC outside temperature sensor Pt1000

................................................................................................................................................................... ...................................................................................................................................................................
Sensors & Counters CONTROL AND MEASURING INSTRUMENTS

Art. No.

0802118

0802159

Model Measuring principle Measuring range Protection mode Connection Dimensions (W / H / D) Casing Warranty

TRITEC surface temperature sensor Pt1000, 3 m without stamping Platinum resistance wire -20 to +150 C IP65 Cable, 3 m, two-conductor connection 50 mm / 50 mm / 8 mm Injection moulded plastic with aluminium plate, incl. adhesive tape 2 years

TRITEC outside temperature sensor Pt1000, PG 9 Platinum resistance wire -20 to +200 C IP65 Cable, 3 m, two-conductor connection 52 mm / 50 mm / 32 mm Macrolone housing 2 years

119

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Mounting Systems
Our mounting systems allow simple mounting for installations on the roof or the front and for roof integrations. Component and prole tests provide evidence of the excellent stability under maximum snow and wind loads.

TRITEC SCHOTT SOLAR SOLRIF

121

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

On-the-Roof System

TRI-STAND mounting system For pitched roofs, at roofs and fronts


TRI-STAND The mounting system
The development of the new mounting system TRISTAND is based on well-founded know-how and years of practical experience. The knowledge gained from the implementation of numerous solar systems resulted in a mounting system that is ideally suited for all applications from small stand-alone systems to large grid-connected systems, on pitched and at roofs as well as fronts. with great static stresses the universal prole UP-S is used. The revolutionary design of the universal proles allows for two types of installation: the easy to install insertion system with cross bracing and the insertion prole TS or the cost-effective clip system with middle and end clips. The choice is yours.

SafeClick SC The secure connector

Insertion prole TS The aluminium prole

122

The insertion prole TS of the TRISTAND mounting system allows the easy, quick and thus efcient installation of all popular framed solar modules. After the insertion of the modules into the aluminium prole, the modules are held in place by their own weight and friction. The photovoltaic modules do not need to be screwed in.

SafeClicks connect the universal proles of the TRISTAND mounting system securely and easily with its insertion proles. The practical design of the SafeClick allows easy installation by simply clicking in the insertion proles. Drilling is not necessary.

The universal proles UP and UP-S are the basic proles of the TRISTAND mounting system. The universal prole UP is used for standard systems. For applications

Universal prole UP The base prole

In the case of horizontal module insertion and acceptance of pressures of more than 2400 N/m, some module manufacturers specify the use of a middle support. The TRISTAND middle rail TS-M is specically designed for the mounting system and the ideal support for all popular modules.

Middle rail TS-M The optimal reinforcement

Insertion of modules into the cross bracing of proles the stable and installation-friendly version for pitched roofs.

The upright installation represents the more exible and installation-friendly version for at roofs, which can compensate for any unevenness.

................................................................................................................................................................... ...................................................................................................................................................................
On-the-Roof System MOUNTING SYSTEMS

Art. No.

1502199

1502200

1502201

1502202

1502203

Model Application Frame thickness Module brand (examples)

TRI-STAND insertion prole TS-34, 6.000 m, blank aluminium Pitched and at roof 34 mm SolarWorld, Isofoton, Naps Systems, Solartec

Max. rod length Dimensions (L / W / H) * Weight * Art. No.

6.00 m 1000 mm / 54 mm / 50 mm 1.1 kg 1502204

TRI-STAND insertion prole TS-35, 6.000 m, blank aluminium Pitched and at roof 35 mm Sanyo, Solarfabrik, Wrth Solar, Canadian Solar, DAY4 Energy, GE Energy, Mitsubishi Heavy Industries, Solara, Solarfun Power, Suntech Power, Viessmann 6.00 m 1000 mm / 54 mm / 51 mm 1.1 kg 1502205

TRI-STAND insertion prole TS-40, 6.000 m, blank aluminium Pitched and at roof 40 mm Isofoton, Topsolar, Bisol, Canadian Solar, Kaneka, MSK, Siliken

TRI-STAND insertion prole TS-42, 6.000 m, blank aluminium Pitched and at roof 42 mm Kaneka, Five Star Energy, Ibersolar Energia, MDT technologies, Scheuten Solar Technology, Solon

TRI-STAND insertion prole TS-46, 6.000 m, blank aluminium Pitched and at roof 46 mm Kyocera, Sharp, Sunpower, Chaori, Kaneka, Mitsubishi Electric, MSK, Sanyo Electric, Shanghai Chaori Solar Energy, Vaillant 6.00 m 1000 mm / 54 mm / 62 mm 1.2 kg 1502208

6.00 m 1000 mm / 54 mm / 56 mm 1.2 kg 1502206

6.00 m 1000 mm / 54 mm / 58 mm 1.2 kg 1502207

Model Application Frame thickness Module brand (examples)

Max. rod length Dimensions (L / W / H) * Weight * Continued on next page

TRI-STAND insertion prole TS-50, 6.000 m, blank aluminium Pitched and at roof 50 mm Schott, Yingli, Aleo, BP Solar, Unisolar, Eging, Advent Solar, Aleo Solar, Atersa, MDT technologies, Solara, Solarfabrik, Solarwatt, Sunlink PV, Suntech Power, Sunways Photovoltaic, Vaillant, Viessmann 6.00 m 1000 mm / 54 mm / 66 mm 1.2 kg

TRI-STAND insertion prole TS-34, 6.000 m, black Pitched and at roof 34 mm SolarWorld, Isofoton, Naps Systems, Solartec

TRI-STAND insertion prole TS-35, 6.000 m, black Pitched and at roof 35 mm Sanyo, Solarfabrik, Wrth Solar, Canadian Solar, DAY4 Energy, GE Energy, Mitsubishi Heavy Industries, Solara, Solarfun Power, Suntech Power, Viessmann 6.00 m 1000 mm / 54 mm / 51 mm 1.1 kg

TRI-STAND insertion prole TS-40, 6.000 m, black Pitched and at roof 40 mm Isofoton, Topsolar, Bisol, Canadian Solar, Kaneka, MSK, Siliken

TRI-STAND insertion prole TS-42, 6.000 m, black Pitched and at roof 42 mm Kaneka, Five Star Energy, Ibersolar Energia, MDT technologies, Scheuten Solar Technology, Solon

123

6.00 m 1000 mm / 54 mm / 50 mm 1.1 kg

6.00 m 1000 mm / 54 mm / 56 mm 1.2 kg

6.00 m 1000 mm / 54 mm / 58 mm 1.2 kg

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

On-the-Roof System

Art. No.

1502209

1502210

1502211

1502212

1502213

Model Application Frame thickness Module brand (examples)

TRI-STAND insertion prole TS-46, 6.000 m, black Pitched and at roof 46 mm Kyocera, Sharp, Sunpower, Chaori, Kaneka, Mitsubishi Electric, MSK, Sanyo Electric, Shanghai Chaori Solar Energy, Vaillant

Max. rod length Dimensions (L / W / H) * Weight * * - Per meter Accessories Art. No.

6.00 m 1000 mm / 54 mm / 62 mm 1.2 kg

TRI-STAND insertion prole TS-50, 6.000 m, black Pitched and at roof 50 mm Schott, Yingli, Aleo, BP Solar, Unisolar, Eging, Advent Solar, Aleo Solar, Atersa, MDT technologies, Solara, Solarfabrik, Solarwatt, Sunlink PV, Suntech Power, Sunways Photovoltaic, Vaillant, Viessmann 6.00 m 1000 mm / 54 mm / 66 mm 1.2 kg

TRI-STAND middle rail TS-M, 6.000 m Pitched and at roof Any Middle rail for all TRISTAND insertion proles

TRI-STAND universal prole UP, 6.000 m Pitched roof Any Basic prole for all TRISTAND insertion proles

TRI-STAND universal prole UP-S, 6.000 m Pitched and at roof Any Basic prole for all TRISTAND insertion proles

6.00 m 1000 mm / 85 mm / 17 mm 0.8 kg

6.00 m 1000 mm / 40 mm / 41 mm 1.3 kg

6.00 m 1000 mm / 70 mm / 41 mm 1.6 kg

1502214

1502215

1502216

1502217

1502218

124

Model Application Dimensions (L / W / H) Weight Art. No.

TRI-STAND end bracket TRI-STAND SafeClick SC TS-E Pitched and at roof Pitched and at roof 32 mm / 29 mm / 33 mm 13 mm / 45 mm / 70 mm 0.010 kg 1502219 0.050 kg 1502222

TRI-STAND insertion prole connector TS-C Pitched and at roof 95 mm / 64 mm / 17 mm 0.080 kg 1502223

TRI-STAND universal prole connector UP-C Pitched and at roof 120 mm / 51 mm / 41 mm 0.130 kg 1502224

TRI-STAND slide nut M8 Pitched and at roof 32 mm / 21 mm / 9 mm 0.010 kg 1502225

Model Application Dimensions (L / W / H) Weight Continued on next page

TRI-STAND slide nut M10

TRI-STAND FlexFix

TRI-STAND Z adapter UP-Z

Pitched and at roof Flat roof Pitched and at roof 32 mm / 21 mm / 9 mm 65 mm / 40 mm / 35 mm 102 mm / 30 mm / 34 mm 0.010 kg 0.150 kg 0.200 kg

TRI-STAND spacer UP-D, TRI-STAND middle clip 3 mm (34 - 40 mm), blank aluminium Pitched and at roof Pitched and at roof 56 mm / 35 mm / 6 mm 70 mm / 35 mm / 27 mm 0.100 kg 0.100 kg

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

................................................................................................................................................................... ...................................................................................................................................................................
On-the-Roof System MOUNTING SYSTEMS

Art. No.

1502226

1502227

1502228

1502229

1502230

Model Application Dimensions (L / W / H) Weight Art. No.

TRI-STAND middle clip (41 - 50 mm), blank aluminium Pitched and at roof 70 mm / 35 mm / 27 mm 0.100 kg 1502233

TRI-STAND end clip 34 mm, blank aluminium Pitched and at roof Pitched and at roof Pitched and at roof 70 mm / 35 mm / 27 mm 70 mm / 35 mm / 27 mm 50 mm / 34 mm / 27 mm 0.100 kg 0.100 kg 0.040 kg 1502234 1502235

TRI-STAND middle clip (34 - 40 mm), black

TRI-STAND middle clip (41 - 50 mm), black

TRI-STAND end clip 35 mm, blank aluminium Pitched and at roof 50 mm / 35 mm / 27 mm 0.040 kg

1502236

Model Application Dimensions (L / W / H) Weight Art. No.

TRI-STAND end clip 40 mm, blank aluminium Pitched and at roof 50 mm / 40 mm / 27 mm 0.040 kg 1502237

TRI-STAND end clip 42 mm, blank aluminium Pitched and at roof 50 mm / 42 mm / 27 mm 0.040 kg 1502238

TRI-STAND end clip 46 mm, blank aluminium Pitched and at roof 50 mm / 46 mm / 27 mm 0.040 kg 1502241

TRI-STAND end clip 50 mm, blank aluminium Pitched and at roof 50 mm / 50 mm / 27 mm 0.040 kg 1502242

125
Model Application Dimensions (L / W / H) Weight Art. No. TRI-STAND end clip 34 mm, black Pitched and at roof 50 mm / 34 mm / 27 mm 0.040 kg 1502243 TRI-STAND end clip 35 mm, black Pitched and at roof 50 mm / 35 mm / 27 mm 0.040 kg 1502244 TRI-STAND end clip 40 mm, black Pitched and at roof 50 mm / 40 mm / 27 mm 0.040 kg 1502245 TRI-STAND end clip 42 mm, black Pitched and at roof 50 mm / 42 mm / 27 mm 0.040 kg 1502246

Model Application Dimensions (L / W / H) Weight

TRI-STAND end clip 46 mm, black Pitched and at roof 50 mm / 46 mm / 27 mm 0.040 kg

TRI-STAND end clip 50 mm, black Pitched and at roof 50 mm / 50 mm / 27 mm 0.040 kg

TRI-STAND cross cable clip block UP-K Pitched and at roof 22 mm / 22 mm / 16 mm 0.002 kg

TRI-STAND edge clip TS-EC Pitched and at roof 18 mm / 15 mm / 11 mm 0.001 kg

TRI-STAND has successfully passed the TV tests. Patent applications have been led for SafeClick and FlexFix. Other TRI-STAND prole types upon request.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

On-the-Roof System

TRI-STAND mounting accessories


Roof hooks Hanger bolts

For the assembly of substructures rst fastenings must be installed at the appropriate grid spacings. On tiled roofs, the roof hooks are attached either directly to the rafter or to distance battens above the rafter. Roof hooks are available for almost any type of tile and are secured by means of seating bolts.

For the installation on a corrugated roof type, the existing screws are replaced by hanger bolts. This secures the corrugated roof, and at the same time the hanger bolts can be used for the installation of the substructure. This provides the base for the installation with a minimum of time and effort.

Roof fold clamps

In the case of plate fold roofs, the clamps are installed directly at the fold. The clamps consist of two stainless steel metal sheets, which are bolted together. The roof fold clamps are available in a round version, especially for Kalzip roofs. The substructure can be mounted on the clamps, without disturbing the roof surface. 126

Renosol plates

For at roofs, generally Renosol plates are used. The gravel is removed from the required at roof area, a protective mat or eece is laid and the Renosol plate is placed on this. Then the TRISTAND proles UP and UPS can be riveted directly to the Renosol plate. Finally, the Renosol plates must be weighed down again with gravel, in order to meet the static requirements.

As standard, roof hooks are available in xed or once adjustable versions and are suited to almost any type of tile.

Using plate fold clamps, the TRISTAND proles can be attached to the plate fold roof directly.

................................................................................................................................................................... ...................................................................................................................................................................
On-the-Roof System MOUNTING SYSTEMS

Art. No.

1502247

1502248

1502249

1502305

1502306

Model Application Art. No.

TRI-STAND bracket 90, without screw Flat roof and building exterior 1502308

TRI-STAND bracket 110, without screw Flat roof and building exterior 1502250

TRI-STAND bracket 120, without screw Flat roof and building exterior 1502251

TRI-STAND bracket 150, without screw Flat roof and building exterior 1502252

TRI-STAND bracket 160, without screw Flat roof and building exterior 1502253

Model Application Art. No.

TRI-STAND at connector, for stiffening Flat roof and building exterior 1502278

TRI-STAND SafeClick basic element Pitched roof, at roof and building exterior 1502254

TRI-STAND lens head screw M8x25 A2 Pitched roof, at roof and building exterior 1502255

TRI-STAND retaining washer M8x25 A2 Pitched roof, at roof and building exterior 1502256

TRI-STAND round-head screw M10x30 A2 Pitched roof, at roof and building exterior 1502280

127
Model Application Art. No. TRI-STAND round-head TRI-STAND self-locking screw M10x50 A2 nut with serrated bearing surface M10 A4 Pitched roof, at roof Pitched roof, at roof and building exterior and building exterior 1502257 1502258 TRI-STAND hammerTRI-STAND hexagon head screw M10x30 A2 bolt M10x25 A2 Pitched roof, at roof and building exterior 1502259 Pitched roof, at roof and building exterior 1502260 TRI-STAND cable tie pliers Pitched roof, at roof and building exterior 1502279

Model Application Art. No.

TRI-STAND Renosol plate 800x600x35 Flat roof 1502261

TRI-STAND Peel rivet TRI-STAND Peel rivet incl. washer, M8 73x6.3 without washer, M8 73x6.3 Flat roof Flat roof 1502264 1502265

TRI-STAND washer M8 23x8.4, for Peel rivet Flat roof 1502266

TRI-STAND rivet gun Flat roof 1502267

Model Application Continued on next page

TRI-STAND hanger bolt TRI-STAND hanger bolt TRI-STAND hanger bolt TRI-STAND roof hook M12x250 M12x300 M12x350 xed Pitched and at roof Pitched and at roof Pitched and at roof Pitched roof

TRI-STAND roof hook once variable Pitched roof

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

On-the-Roof System

Art. No.

1502270

1502271

1502272

1502273

Model Application Art. No.

TRI-STAND crown tile roof hook xed Pitched roof 1502274

TRI-STAND crown tile roof hook once variable Pitched roof 1502275

TRI-STAND slate roof hook xed Pitched roof 1502276

TRI-STAND slate roof hook once variable Pitched roof 1502277

Model Application Art. No.

TRI-STAND trapezoidal plate shoe, with bracket, M10 Pitched roof 1502281

TRI-STAND fold clamp for plate fold roof, M10 Pitched roof 1502282

TRI-STAND fold clamp for Kalzip roof, M10 Pitched roof 1502283

TRI-STAND Zambelli clamp for Ribroof Pitched roof 1502284

128

Model Application

TRI-STAND seating bolt 8.0x80 TRI-STAND seating bolt 8.0x120 Pitched roof Pitched roof

TRI-STAND seating bolt 8.0x160 Pitched roof

TRI-STAND seating bolt 8.0x200 Pitched roof

The hanger bolts are available in different lengths to allow the perfect alignment with the existing corrugated roof shape.

The Renosol plates are used for installations on at roofs and weighed down with gravel for example.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

129

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

Trapezoidal Sheet System

TRI-VENT mounting system For trapezoidal sheet roofs


The mounting system
The development of the TRIVENT mounting system particularly emphasised great exibility, good installation features and great safety. The system was specifically designed for the installation of solar systems on trapezoidal sheet roofs and combines the above benets into a professional solution.

Extremely easy installation

130

The different components of the system allow the installation on almost any trapezoidal roof. Due to the TRIVENT support proles with their different lengths and several drill holes at intervals of 90 mm to 350 mm, the system can be used for all roof types. The two versions of the TRIVENT module armatures can accommodate modules with frame strengths of 35 mm, 40 mm, 46 mm and 50 mm. Additionally, the system allows for the solar modules to be installed vertically and horizontally.

Greatest exibility

The complete system can be installed on the roof as simply as possible and with a minimum number of tools. Having measured the roof and drilled the holes, the TRIVENT support proles are riveted to the roof. Then the modules are inserted, followed by the module armatures, and then they are secured at the end of each row, using the TRIVENT bending tool. Tiresome screwing in is completely dispensed with. The short proles and easy-to-handle components enable the simple and easy transport of the system to and onto the roof, thus saving energy, time and money.

Best safety

The system, designed for wind and snow loads, provides best stability and safety even in extreme weather conditions. Each module is secured against slipping with the TRIVENT retaining rings of the mounting system. The support proles, bent with the TRIVENT bending tool, give additional stability to the system and prevent the slipping of all modules.

The TRIVENT support proles are only riveted to the roof at the points required by the module installation.

The few components of the TRIVENT mounting system enable the easy, quick and safe installation.

................................................................................................................................................................... ...................................................................................................................................................................
Trapezoidal Sheet System MOUNTING SYSTEMS

Art. No.

1502360

1502361

1502362

1502363

1502364

Model Frame thickness Module brand (examples)

Dimensions (L / W / H) Weight Application Art. No.

TRI-VENT end module armature (35 and 46 mm) 35 / 46 mm Sanyo, Solarfabrik, Wrth Solar, Canadian Solar, DAY4 Energy, GE Energy, Mitsubishi Heavy Industries, Solara, Solarfun Power, Suntech Power, Viessmann, Kyocera, Sharp, Sunpower, Chaori, Kaneka, Mitsubishi Electric, MSK, Sanyo Electric, Shanghai Chaori Solar Energy, Vaillant 50 mm / 30 mm / 30 mm 0.040 kg Trapezoidal sheet roof 1502365

TRI-VENT middle module armature (35 and 46 mm) 35 / 46 mm Sanyo, Solarfabrik, Wrth Solar, Canadian Solar, DAY4 Energy, GE Energy, Mitsubishi Heavy Industries, Solara, Solarfun Power, Suntech Power, Viessmann, Kyocera, Sharp, Sunpower, Chaori, Kaneka, Mitsubishi Electric, MSK, Sanyo Electric, Shanghai Chaori Solar Energy, Vaillant 60 mm / 30 mm / 30 mm 50 mm / 20 mm / 20 mm 0.040 kg 0.026 kg Trapezoidal sheet roof Trapezoidal sheet roof 1502366 1502367

TRI-VENT end module armature (40 and 50 mm) 40 / 50 mm Isofoton, Topsolar, Bisol, Canadian Solar, Kaneka, MSK, Siliken Schott, Yingli, Aleo, BP Solar, Unisolar, EGing, Advent Solar, Aleo Solar, Atersa, MDT technologies, Solara, Solarfabrik, Solarwatt, Sunlink PV, Suntech Power, Sunways Photovoltaic, Vaillant, Viessmann

TRI-VENT middle module armature (40 and 50 mm) 40 / 50 mm Isofoton, Topsolar, Bisol, Canadian Solar, Kaneka, MSK, Siliken Schott, Yingli, Aleo, BP Solar, Unisolar, EGing, Advent Solar, Aleo Solar, Atersa, MDT technologies, Solara, Solarfabrik, Solarwatt, Sunlink PV, Suntech Power, Sunways Photovoltaic, Vaillant, Viessmann

TRI-VENT module armature plate (end and middle) All framed modules

60 mm / 20 mm / 20 mm 50 mm / 40 mm / 30 mm 0.026 kg 0.016 kg Trapezoidal sheet roof Trapezoidal sheet roof 1502368 1502369

131
Model Frame thickness Module brand (examples) Dimensions (L / W / H) Weight Application Art. No. TRI-VENT support prole 070 All framed modules 100 mm / 60 mm / 30 mm 0.077 kg Trapezoidal sheet roof 1502370 TRI-VENT support prole 090 - 150 All framed modules 230 mm / 60 mm / 30 mm 0.177 kg Trapezoidal sheet roof 1502371 TRI-VENT support prole 180 - 240 All framed modules 320 mm / 60 mm / 30 mm 0.246 kg Trapezoidal sheet roof 1502372 TRI-VENT support prole 235 - 295 All framed modules 385 mm / 60 mm / 30 mm 0.289 kg Trapezoidal sheet roof TRI-VENT support prole 290 - 350 All framed modules 430 mm / 60 mm / 30 mm 0.331 kg Trapezoidal sheet roof

1502378

Model Frame thickness Module brand (examples) Dimensions (L / W / H) Weight Application Accessories Art. No. 1502373 1502374 1502379 1502408

TRI-VENT rubber seal (2 per support prole) All framed modules 30 mm / 20 mm / 1 mm 0.002 kg Trapezoidal sheet roof

TRI-VENT sealing rivets (2 per TRI-VENT retaining rings (2 per support prole) module) All framed modules All framed modules 50 mm / 5 mm / 5 mm 30 mm / 30 mm / 2 mm 0.004 kg 0.010 kg Trapezoidal sheet roof Trapezoidal sheet roof

TRI-VENT edge clip All framed modules 18 mm / 15 mm / 11 mm 0.001 kg Trapezoidal sheet roof

Model TRI-VENT drilling gauge TRI-VENT bending tool TRI-VENT riveting machine PowerBird, (rivet 6.3 mm) TRI-VENT PowerBird rechargeable battery 12V 2A

Description For the measuring of the TRIVENT system Special tool for horizontal xing TRIVENT accessories, rivet diameter 6.3 mm TRIVENT accessories, rivet diameter 6.3 mm

Dimensions (L / W / H) Weight 2000 mm / 1000 mm / 100 mm 2.5 kg (approx.) 300 mm / 30 mm / 30 mm 500 mm / 500 mm / 100 mm 100 mm / 100 mm / 100 mm 0.5 kg (approx.) 4.2 kg (approx.) 1.2 kg (approx.)

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

Roof-integrated System

Schott InDaX The in-roof system


Perfect installation features
Due to the low system weight and minimised number of components, the installation of the Schott InDaX system is extremely easy and efcient. This is also supported by the exible installation sequence. Uneven areas in the roof can simply be compensated for by means of the separate rain gutters between the modules.

Optimum safety

Perfect aesthetics, maximum energy yields

Designed for roof slopes of 12 to 65 degrees, the Schott InDaX system provides absolute rain proong. In special wind tunnel tests, the system was successfully tested for wind and rain combinations with wind speeds of up to 130 km/h. The system replaces conventional roof coverings and assumes all protection functions against wind load, snow load, precipitation, ying sparks and radiating heat. All InDaX modules are approved for surface loads of up to 550 kg/m.

132

The perfect visual appearance of the InDaX system is not only due to the classy black module frame, but also to its low overall height. The system integrates perfectly into the roof surface and therefore meets the highest architectural demands. In addition, the arrangement of the modules in a shingled array and the specically developed frame provide optimum rear-ventilation of the modules and thus ensure optimum energy yields.

Advantages in brief
n n n n n

Easy installation Replaces the roof covering Perfect aesthetics Maximum energy yields Tested rain proong

The Schott InDaX system integrates perfectly into the roof, due to the special frame.

Easy and quick installation is ensured by the minimum number of components and the low system weight.

................................................................................................................................................................... ...................................................................................................................................................................
Roof-integrated System MOUNTING SYSTEMS

Art. No.

0101205

0101206

Model Nominal power Max. system voltage Operating voltage Operating current Open circuit voltage Short circuit current Temp. coefcient power Temp. coefcient voltage Temp. coefcient current Operating module temperature Reverse current load Cells per module Cell type Cell dimensions (L / W) Connection Mounting frame Dimensions (L / W / H) Weight Max. load Performance warranty * Product warranty Norms

Schott InDaX 214 214 W 4 % 1000 V 29.5 V 10 % 7.26 A 10 % 36.3 V 10 % 8.04 A 10 % -0.43 %/K -0.33 %/K 0.05 %/K -40 to +85 C Don't apply external voltages in excess of Uoc to the module 60 pc. MAIN-Iso (polycrystalline silicon) 156 mm / 156 mm Tyco connectors, length per pole 1.1 m Black anodized aluminium 1769 mm / 999 mm / 75 mm 24 kg 5400 N/m 10 / 25 years 5 years IEC 61215 ed. 2, IEC 61730, DIN EN 15601, DIN EN 1187 pt. 1 and 2, protection class II, CE mark

Schott InDaX 225 225 W 4 % 1000 V 29.8 V 10 % 7.55 A 10 % 36.7 V 10 % 8.24 A 10 % -0.43 %/K -0.33 %/K 0.05 %/K -40 to +85 C Don't apply external voltages in excess of Uoc to the module 60 pc. MAIN-Iso (polycrystalline silicon) 156 mm / 156 mm Tyco connectors, length per pole 1.1 m Black anodized aluminium 1769 mm / 999 mm / 75 mm 24 kg 5400 N/m 10 / 25 years 5 years IEC 61215 ed. 2, IEC 61730, DIN EN 15601, DIN EN 1187 pt. 1 and 2, protection class II, CE mark

133

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC) Accessories Art. No. 1502449 1502450 1502451 1502452 1502453 Model Schott InDaX Schott InDaX Schott InDaX Schott InDaX Schott InDaX Description InDaX installation InDaX installation InDaX installation InDaX installation InDaX installation

basic set (2x2 modules) add-on set horizontal add-on set vertical module drainage set roof ridge fastening

accessory accessory accessory accessory accessory

(basic set) (roof ridge - eaves) (side add-on sheets) (2 rain gutters)

The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C. Photos Schott Solar AG

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS

...................................................................................................................................................................

Roof-integrated System

Solrif The solar roof intergration


Versatile and exible
Solrif is suited to numerous types of sloping roofs. It can be used to cover a roof completely, resulting in a reduction of the conventional tile covering. Since their market launch in 1999, installations with a total output of several MWp have been erected. This success is guaranteed by the long years of experience and the versatile applicability.

Aesthetics and optimum operating performance

Installation simple and fast

134

The modules can be installed simply and quickly they are based on the same principle as laying roof tiles: The sections interlock horizontally, giving plenty of vertical play. They are held in place by metal stirrups xed to the roof battens. This conguration allows each Solrif module to be individually removed and replaced. The sections are specially designed to let snow slide off easily and rainwater to run off quickly so that the solar cells always generate the maximum amount of power.

The Solrif Roof Integration System achieves both a high-quality architectonic photovoltaic installation and an efcient electrical operating performance. The Solrif proles can be combined with various roofing materials. The low prole height of the frames results in a good rear ventilation of the solar laminates. In 2006 a Solrif installation with 110 kWp on an agricultural building won the Swiss and European Solar Prize, thanks to the superior design and high output.

Tested quality

Already in September 2005, Solrif was awarded the TV certicate after inspection of the manufacturing facilities and review of the order processing TVdotCOM-ID 7095. Since the award of the test mark the TV Rheinland carries out regular manufacturing controls. Solrif has furthermore been tested with laminate modules of various manufacturers by the TV Rheinland according to IEC 61215 and has passed these tests in accordance with the generally accepted standards.

The efcient Solrif roof integration system offers a perfect design in combination with optimum everyday protection.

Two interlocking frame proles are t into a clamp on the lower side and fastened at the upper edge to the next module row.

................................................................................................................................................................... ...................................................................................................................................................................
Roof-integrated System MOUNTING SYSTEMS

Art. No. Model For laminate Roof slope Wood substructure Norms Accessories Art. No. 1502427 1502428 1502429 1502430 1502431 1502432 1502433 1502434 1502435 1502437 1502438 1502439 1502440 1502441 1502442 1502443 1502444 1502445 1502447 1502448 1502098 1502111 1502112 1502113

0101204 Solrif framed FD135GH-2P with cable + MC3 FD135GH-2P (1499 x 708 x 25 mm) 15 - 70, below 25 with underlay foil Analogous to a tiled roof IEC 61215-1-1, IEC 61024-1, TVdotCOMID: 0000007095

0101203 Solrif framed Romag SMT6(48)P 180W Romag SMT6(48)P 180W (1312 x 988 x 4.6 mm) 15 - 70, below 25 with underlay foil Analogous to a tiled roof IEC 61215-1-1, IEC 61024-1, TVdotCOMID: 0000007095

0101202 Solrif framed Romag SMT6(48)P 185W Romag SMT6(48)P 185W (1312 x 988 x 4.6 mm) 15 - 70, below 25 with underlay foil Analogous to a tiled roof IEC 61215-1-1, IEC 61024-1, TVdotCOMID: 0000007095

Model Solrif ridge plate left, bk, for FD135GH-2P Solrif ridge plate right, bk, for FD135GH-2P Solrif ridge plate center, bk, for FD135GH-2P Solrif side plate above left, bk, for FD135GH-2P Solrif side plate above right, bk, for FD135GH-2P Solrif side plate left, bk, for FD135GH-2P Solrif side plate right, bk, for FD135GH-2P Solrif edge connection prole left for FD135GH-2P Solrif edge connection prole right for FD135GH-2P Solrif ridge plate left, bk, for SMT6(48)P Solrif ridge plate right, bk, for SMT6(48)P Solrif ridge plate center, bk, for SMT6(48)P Solrif side plate above left, bk, for SMT6(48)P Solrif side plate above right, bk, for SMT6(48)P Solrif side plate left, bk, for SMT6(48)P Solrif side plate right, bk, for SMT6(48)P Solrif edge connection prole left for SMT6(48)P Solrif edge connection prole right for SMT6(48)P Solrif bracket prole 2.0 mm, black Solrif bracket glass 2.0 mm, black Solrif bracket above 2.0 mm Solrif gum joint cover, l = 30 cm Solrif metal bracket for all plates per 2 pcs. Solrif roof valley sealing strip, l = 100 cm

Description Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection plate for FD135GH-2P Edge connection prole for FD135GH-2P Edge connection prole for FD135GH-2P Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection plate for Romag SMT6(48)P 180/185W Edge connection prole for Romag SMT6(48)P 180/185W Edge connection prole for Romag SMT6(48)P 180/185W Solrif roof mounting component Solrif roof mounting component Solrif roof mounting component Siding sealing for the joint of 2 ridge plates Fastening of plates to battens Bottom sealing of the complete generator width

135

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Accessories
Our accessories include exible cables particularly suited for solar systems. The cables are extremely robust, mechanically resistant, free of halogen as well as UV- and weather-resistant. In addition, our range of accessories includes any item needed for the assembly and maintenance of solar systems.

DRAKA HUBER+SUHNER STUDER MULTI-CONTACT TYCO RENNSTEIG PHOENIX CONTACT


137

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Solar Cable

Drakaex Sun Betax The halogen-free solar cable


Best quality
Drakaex Sun Betax solar cables are specically designed and manufactured for use in solar applications. They satisfy with their reliability, excellent life-cycle and optimal physical qualities. All cables are tested and certied according to established international testing methods and meet the highest demands. ame-retardant, do not contain halogen components and do not generate corrosive gases in case of re, but only a little smoke. The used materials do not contain attractants for martens and are resistant against ammonia. The jacket is separated from the insulation and therefore easier to strip off. The cables are compatible with all major connector systems.

Use

Drakaex Sun Betax solar cables have been developed for use outdoors. Equally, they can be used indoors. They are used to connect two solar modules (cable run), solar modules and inverters (sub-array run) or as main direct current line.

Advantages in brief
n n n n n n

Features
138

n n

Drakaex Sun Betax solar cables satisfy with their outstanding product qualities. The used materials are

Resistant against ozone, UV and weather Halogen-free Flame-retardant Microbe-resistant Reduced diameter Life expectation of more than 30 years Oil-resistant Ecologically safe fulll the RoHS directive 2002/95/EG

Drakaex Sun Betax resist ames, ozone and weather.

The practical 500 m drum.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Cable ACCESSORIES

Art. No.

1302191

1302192

1302193

1302194

1302195

1302196

Model Cross section Colour Cable diameter Rated voltage Min. bending radius Temperature range Short-circuit-resistant up to temperature of * Conductor Insulation Weight ** Warranty Norms

Draka Sun Betax 125, 4 rd, 500 m drum 4.0 mm Red 5.5 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 218 A Tinned exible copper lead, newire Betax 125 6.1 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

Draka Sun Betax 125, 4 bu, 500 m drum 4.0 mm Blue 5.5 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 218 A Tinned exible copper lead, newire Betax 125 6.1 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

Draka Sun Betax 125, 4 bk, 500 m drum 4.0 mm Black 5.5 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 218 A Tinned exible copper lead, newire Betax 125 6.1 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

Draka Sun Betax 125, 6 rd, 500 m drum 6.0 mm Red 6.4 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 327 A Tinned exible copper lead, newire Betax 125 8.7 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

Draka Sun Betax 125, 6 bu, 500 m drum 6.0 mm Blue 6.4 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 327 A Tinned exible copper lead, newire Betax 125 8.7 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

Draka Sun Betax 125, 6 bk, 500 m drum 6.0 mm Black 6.4 mm 0.2 mm 1000 V DC 5 x diameter (exing), 4 x diameter (xed) -40 to +90 C 327 A Tinned exible copper lead, newire Betax 125 8.7 kg 2 years IEC 60228, class 5, TV type approved certicate no. R 60023299

* - Short-circuit temperature 200 C, conductor temperature 90 C, duration of short-circuit 5 seconds ** - Nominal kg/100 m

139

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Solar Cable

Radox solar cables UV-resistant, halogen-free and extremely rugged


Radox solar cables are exible single-core and multicore cables specically suitable for the wiring of solar installations both inside buildings and outside. material displays absolutely no shrinkage and absolutely no other changes over time. This is of advantage particularly for coating and potting and for tting connectors. Even at high temperatures, the electron beam-crosslinked material does not melt or ow. Nevertheless, the insulation can be stripped easily from the cables. The fact that the material contains no halogens means that no corrosive or toxic gases are produced and little smoke is generated in the event of a re. The cable insulation is ame-retardant and can consequently not catch re of its own accord.

Long service life

The cables are extremely rugged, feature an extremely high mechanical resistance and are extremely resistant to heat, low temperature, oil, abrasion, UV, ozone and weathering. These properties guarantee a long service life. All these properties are achieved with small outside diameters thanks to Radox technology and high precision.

Absolutely no shrinkage

The cables are easy to process owing to the close manufacturing tolerances. The electron beam-crosslinked 140

1
2

Radox solar cables used successfully worldwide for many years now. Operating temperature range -40 to +120C, short-circuit-resistant up to temperatures of +280C.

Radox single-core solar cable 1) Conductor: Tinned exible copper lead, ne-wire 2) Insulation: Radox black 3) Jacket: Radox, colours see technical data

................................................................................................................................................................... ...................................................................................................................................................................
Solar Cable ACCESSORIES

Art. No.

1302175

1302178

1302176

1302179

1302177

Model Cross section Colour Cable diameter Rated voltage Min. bending radius Temperature range Short-circuit-resistant up to temperature of Conductor Insulation Weight * Warranty Norms

Radox solar cable 4 rd, 100 m drum 4.0 mm Red 5.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +120 C +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 1302180

Radox solar cable 4 rd, 500 m drum 4.0 mm Red 5.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +120 C +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 1302181

Radox solar cable 4 bu, 100 m drum 4.0 mm Blue 5.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +120 C +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 1302184

Radox solar cable 4 bu, 500 m drum 4.0 mm Blue 5.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +120 C +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086

Radox solar cable 4 bk, 100 m drum 4.0 mm Black 5.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +120 C +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086

Art. No.

1302182

Model Cross section Colour Cable diameter Rated voltage Min. bending radius Temperature range Short-circuit-resistant up to temperature of Conductor Insulation Weight * Warranty Norms

Radox solar cable 4 bk, 500 m Radox solar cable 6 rd, 100 m Radox solar cable 6 rd, 500 m Radox solar cable 6 bu, 100 m drum drum drum drum 4.0 mm 6.0 mm 6.0 mm 6.0 mm Black Red Red Blue 5.8 mm 0.15 mm 6.9 mm 0.20 mm 6.9 mm 0.20 mm 6.9 mm 0.20 mm 1000 V DC 1000 V DC 1000 V DC 1000 V DC 4 x diameter 4 x diameter 4 x diameter 4 x diameter -40 to +120 C -40 to +120 C -40 to +120 C -40 to +120 C +280 C (max. 5 seconds) +280 C (max. 5 seconds) +280 C (max. 5 seconds) +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 6.6 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086

141

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Solar Cable

Art. No.

1302185

1302183

1302186

1301323

Model Cross section Colour Cable diameter Rated voltage Min. bending radius Temperature range Short-circuit-resistant up to temperature of Conductor Insulation Weight * Warranty Norms

Radox solar cable 6 bu, 500 m Radox solar cable 6 bk, 100 m Radox solar cable 6 bk, 500 m Radox solar cable 10 bk drum drum drum 6.0 mm 6.0 mm 6.0 mm 10.0 mm Blue Black Black Black 6.9 mm 0.20 mm 6.9 mm 0.20 mm 6.9 mm 0.20 mm 8.1 mm 0.15 mm 1000 V DC 1000 V DC 1000 V DC 1000 V DC 4 x diameter 4 x diameter 4 x diameter 6 x diameter -40 to +120 C -40 to +120 C -40 to +120 C -40 to +120 C +280 C (max. 5 seconds) +280 C (max. 5 seconds) +280 C (max. 5 seconds) +280 C (max. 5 seconds) Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 9.2 kg 15 years IEC 60228, class 5, TV type approved certicate no. R 02210086 Tinned exible copper lead, ne-wire Radox black 14.4 kg 15 years IEC 60228, class 5

* - Nominal kg/100 m

142

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

143

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Solar Cable

Studer Betaam Solar Innovative solar cables


Leoni Studer AG Internationally proven
With more than 34,000 employees in over 100 locations in 30 countries, the company is one of the leading manufacturers of cables, conduits and grid systems. The business unit "Wind and Solar Power" contributes to a high-quality broad cable range for the sectors industry, infrastructure and energy. It produces cables and for these develops and processes superior compounds for conductor insulation. Leoni Studer AG is part of the internationally active Leoni Group and represents highest quality and innovative technology. and can unreservedly be used as module and connecting cables for stand-alone and grid-connected systems.

Safe design
n n

Conductor: Braided copper wire, tinned, ne, class 5 Insulation: Polyolen Copolymer electron beam cross-linked Jacket: Polyolen Copolymer electron beam crosslinked

Advantages in brief
n n n n n n n

Best features

144

Long life-cycle and optimum weather resistance with these features, Leoni Studer solar cables meet all requirements made of solar systems and their components. The double-insulated, electron beam crosslinked cables meet the highest standards of solar cables

UV and ozone resistant Hydrolysis resistant Electron beam cross-linked compounds High temperature resistance Cold exibility Long life-cycle Compatible with all major connectors

The double insulated electron beam cross-linked solar cables of Studer are suitable for grid-connected and stand-alone systems.

The Studer solar cables are UV and ozone resistant and suited for a temperature range of -40 up to +85C.

................................................................................................................................................................... ...................................................................................................................................................................
Solar Cable ACCESSORIES

Art. No.

1302197

1302198

Model Cross section Colour Cable diameter Rated voltage Min. bending radius Temperature range Short-circuit-resistant up to temperature of Conductor Insulation Weight * Warranty Norms * - Nominal kg/100 m

Studer Betaam 125 ex, 4 mm bk, 500 m drum 4.0 mm Black 5.9 mm 0.15 mm 1000 V DC 4 x diameter -40 to +85 C +280 C Tinned exible copper lead, ne-wire Polyolen Copolymer electron beam cross-linked 7.0 kg 2 years IEC 60332-1, IEC 61034, EN 50268-2, DIN 51900, TV PfG 1169/08.2007 PV1-F

Studer Betaam 125 ex, 6 mm bk, 500 m drum 6.0 mm Black 6.8 mm 0.15 mm 1000 V DC 4 x diameter -40 to +85 C +280 C Tinned exible copper lead, ne-wire Polyolen Copolymer electron beam cross-linked 9.7 kg 2 years IEC 60332-1, IEC 61034, EN 50268-2, DIN 51900, TV PfG 1169/08.2007 PV1-F

145

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Plugs and Sockets

Multi-Contact MC3 and MC4 connector systems


Multi-Contact AG was founded in 1962 and is currently employing more than 700 staff. All manufacturing sites are ISO 9001-certied and therefore meet the highest quality demands.
n n n n n

MC connector systems

System voltage max. 1000 V Degree of protection, connected IP65 Protection class II Temperature range 40C to +90C TV Rheinland type approved

The components of the MC connector system for photovoltaics are designed to allow time-saving and safe serial and parallel wiring of PV modules for buildingintegrated and free-standing solar installations. For practical use the connector systems MC3 and MC4 are available, depending on the existing modules or inverters.

The interlockable MC4 connector systems


n n n n n n n

The proven MC3 connector systems


n n

n n

146

Diameter 3 mm Rated current max. 30 A for 6 mm max. 20 A for < 4 mm

Diameter 4 mm Rated current max. 30 A System voltage max. 1000 V Degree of protection, connected IP67 Easy installation Locking system "Snap in" Protection class II Temperature range 40C to +90C TV Rheinland type approved

The MC3 plugs and sockets, shown with associated contacts.

The MC4 plugs and sockets, shown with associated contacts.

................................................................................................................................................................... ...................................................................................................................................................................
Plugs and Sockets ACCESSORIES

Art. No.

1302000

1302010

1302050

1302040

1302020

Model Description

MultiContact PV-KBT3II (A: 2 - 4 mm, D: 4.9 7.1 mm) Female type MC3 for Radox / Draka / Studer 4 mm 1302030

MultiContact PV-KST3II (A: 2 - 4 mm, D: 4.9 7.1 mm) Male type MC3 for Radox / Draka / Studer 4 mm 1302073

MultiContact PVKBT3/6III (A: 6 mm, D: 6.5 - 9 mm) Female type MC3 for Radox / Draka / Studer 6 mm 1302085

MultiContact PVKST3/6III (A: 6 mm, D: 6.5 - 9 mm) Male type MC3 for Radox / Draka / Studer 6 mm 1302086

MultiContact PVKBT4/6II (A: 4 - 6 mm, D: 5.5 - 9 mm) Female type MC4 for Radox / Draka / Studer 4 - 6 mm 1302087

Art. No.

Model Description

MultiContact PVMultiContact PV-R-WZ3 KST4/6II (A: 4 - 6 mm, D: 5.5 - 9 mm) Male type MC4 for Installation device for Radox / Draka / Studer 4 male and female MC3 - 6 mm 1302116 1302117

MultiContact PV-ESCZM-19100 crimping pliers insert For MC4 (only use with locator) 1302118

MultiContact PV-CZM16100A crimping pliers For MC3 (MC4: insert and locator necessary)

MultiContact PV-LOC crimping pliers locator For MC4 (only use with crimping pliers insert)

Art. No.

1302115

Model Description Art. No.

MultiContact PV-WZ-AD/GWD MultiContact PV-SSE-AD4 Socket wrench insert for crimping pliers PV-CZM 1302152 Socket wrench insert for crimping pliers PV-CZM 1302153

MultiContact PV-PST test pin For MC type 4 1302154

MultiContact assembly key PVMS For MC type 4 1302155

147

Model Description Continued on next page

MultiContact PV branch plug MC3 PV-AZS3-UR For MC type 3

MultiContact PV branch socket MC3 PV-AZB3-UR For MC type 3

MultiContact PV branch plug MC4 PV-AZS4 For MC type 4

MultiContact PV branch socket MC4 PV-AZB4 For MC type 4

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Plugs and Sockets

Accessories Art. No. 1302071 1302072 1302096 1302097 1302098 1302099 1302120 1302121 1302122 1302123 1302124 1302125 1302126 1302127 1302128 1302129 1302130 1302131 1302132 1302133 1302134

Model MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact MultiContact

PV-A-KBT4/KST3 PV-A-KBT3/KST4 PV-AMLB4/150 measurement line female MC4 PV-AMLS4/150 measurement line male MC4 PV-AMLB3/150 measurement line female MC3 PV-AMLS3/150 measurement line male MC3 PV-A-KBT4/Tyco male plus 4 mm PV-A-KBT4/Tyco female minus 4 mm PV-A-KBT4/Tyco female plus 4 mm PV-A-KBT3/Tyco male minus 4 mm PV-A-KBT3/Tyco male plus 4 mm PV-A-KBT3/Tyco female minus 4 mm PV-A-KBT3/Tyco female plus 4 mm PV-A-KST4/Tyco male minus 4 mm PV-A-KST4/Tyco male plus 4 mm PV-A-KST4/Tyco female minus 4 mm PV-A-KST4/Tyco female plus 4 mm PV-A-KST3/Tyco male minus 4 mm PV-A-KST3/Tyco male plus 4 mm PV-A-KST3/Tyco female minus 4 mm PV-A-KST3/Tyco female plus 4 mm

Description Cable adapter female MC4 for male MC3 Cable adapter female MC3 for female MC4 With PV-KBT4 and security plug 4 mm, blue With PV-KST4 and security plug 4 mm, red With PV-KBT3 and security plug 4 mm, blue With PV-KST3 and security plug 4 mm, red Cable adapter female MC4 for male Tyco Cable adapter female MC4 for female Tyco Cable adapter female MC4 for female Tyco Cable adapter female MC3 for male Tyco Cable adapter female MC3 for male Tyco Cable adapter female MC3 for female Tyco Cable adapter female MC3 for female Tyco Cable adapter male MC4 for male Tyco Cable adapter male MC4 for male Tyco Cable adapter male MC4 for female Tyco Cable adapter male MC4 for female Tyco Cable adapter male MC3 for male Tyco Cable adapter male MC3 for male Tyco Cable adapter male MC3 for female Tyco Cable adapter male MC3 for female Tyco

148

The MC3 plugs are based on contacts with a diameter of 3 mm and comply with protection class IP65.

The interlockable MC4 plugs have contacts with diameters of 4 mm and comply with protection class IP67.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

149

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Plugs and Sockets

Huber+Suhner Radox Connector The innovative connector system


Photovoltaic solar cables and connectors are essential components of solar installations. They ensure the electric connection between the modules and the inverters. They play an important role for the high efciency and long service life of the installations. The expected long service life, adverse exterior environmental inuences and great uctuations of temperatures and humidity make heavy demands on design, material and manufacture. in this form without lamella contacts. As exible elements, these contacts form the mechanical adjustment between plug and socket. The lamella produces a larger contact surface between the elements, thus providing a higher current load capacity with lowest constant contact resistance. All Huber+Suhner solar connectors are compatible for interconnection with each other.

Solar cables and connectors combined

Connector characteristics
n n n n n n

Huber+Suhner solar cables and connectors are perfectly matched, have been specically designed for use in PV installations and have delivered optimal performances for many years.

Lamella contacts The core of the connectors


150 Huber+Suhner's Radox solar connectors consist of casing and contact element. The core of the connectors are the lamella contacts made from high-quality copper beryllium. Comparable values cannot be achieved

n n n n

Temperature range 40C to +110C Max. current carrying capacity 38 A Max. system voltage 1000 V Constant low transition resistance High mechanical resistance UV- and ozone resistant Protection mode IP67 in mated condition Interlockable by means of threads Protection class II TV approval

The interlockable Radox connectors are compatible with 4 or 6 mm Radox cables.

High-quality lamella contacts on turned contact elements with integrated thread lock ensure high functionality and safety.

................................................................................................................................................................... ...................................................................................................................................................................
Plugs and Sockets ACCESSORIES

Art. No.

1302143

1302144

1302145

1302146

Model Connector diameter Contact carrier Contact principle Connectable cross-section Temperature range Current carrying capacity Max. system voltage Contact resistance Protection class Protection mode Warranty Norms

Huber+Suhner Radox male 4 mm 4 mm Brass, tin-plated Copper beryllium lamella contact Radox cable 4 mm -40 to +110 C 38 A at +85 C 1000 V DC < 4 m Class II IP67 in mated condition 2 years DIN VDE 0126-3, TV-certied R 60017637

Huber+Suhner Radox female 4 mm 4 mm Brass, tin-plated Copper beryllium lamella contact Radox cable 4 mm -40 to +110 C 38 A at +85 C 1000 V DC < 4 m Class II IP67 in mated condition 2 years DIN VDE 0126-3, TV-certied R 60017637

Huber+Suhner Radox male 6 mm 4 mm Brass, tin-plated Copper beryllium lamella contact Radox cable 6 mm -40 to +110 C 38 A at +85 C 1000 V DC < 4 m Class II IP67 in mated condition 2 years DIN VDE 0126-3, TV-certied R 60017637

Huber+Suhner Radox female 6 mm 4 mm Brass, tin-plated Copper beryllium lamella contact Radox cable 6 mm -40 to +110 C 38 A at +85 C 1000 V DC < 4 m Class II IP67 in mated condition 2 years DIN VDE 0126-3, TV-certied R 60017637

151

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Plugs and Sockets

Tyco Solarlok The photovoltaic connector system


With 60 years of industry expertise, Tyco Electronics is a worldwide supplier of passive electric and electronic components and one of the leading manufacturers of wiring systems for photovoltaics. nents, in order to signicantly reduce the installation costs of the whole photovoltaic system.

The Solarlok connectors overview


n n n n n

Easy and reliable interconnection

By continuously improving and expanding the Solarlok connector system, Tyco Electronics contributes to the establishment of this environmentally friendly and future-oriented technology on the energy market. The Solarlok connector system represents the easy and reliable interconnection of individual solar modules to the inverter.

n n n

Easy processing on-site Secure connection due to keyed housing Mechanical interlocking Easy multiple plugging Accommodates solar cables of different diameters reliably High current carrying capacity High temperature stability TV and UL certied

The Solarlok concept

The entire system concept is based on cost-effective and reliable processing of individual system compo152

The Tyco Solarlok connectors in different versions for 4 and 6 mm solar cables.

With the Tyco Solarlok system the female and the male are both available with Plus and Minus conguration.

................................................................................................................................................................... ...................................................................................................................................................................
Plugs and Sockets ACCESSORIES

Art. No.

1302102

1302103

1302104

1302105

Model Description Art. No.

Tyco Solarlok male minus 4.0 mm For Radox / Draka / Studer 4 mm 1302106

Tyco Solarlok female minus 4.0 mm For Radox / Draka / Studer 4 mm 1302107

Tyco Solarlok male plus 4.0 mm For Radox / Draka / Studer 4 mm 1302108

Tyco Solarlok female plus 4.0 mm For Radox / Draka / Studer 4 mm 1302109

Model Description Art. No.

Tyco Solarlok male minus 6.0 mm For Radox / Draka / Studer 6 mm 1302166

Tyco Solarlok female minus 6.0 mm For Radox / Draka / Studer 6 mm 1302167

Tyco Solarlok male plus 6.0 mm For Radox / Draka / Studer 6 mm 1302168

Tyco Solarlok female plus 6.0 mm For Radox / Draka / Studer 6 mm 1302169

Model Description Continued on next page

Tyco T-connector (male/male) plus Parallel connection of Tyco Solarlok connectors

Tyco T-connector (male/male) minus Parallel connection of Tyco Solarlok connectors

Tyco T-connector (female/male) plus Parallel connection of Tyco Solarlok connectors

Tyco T-connector (female/male) minus Parallel connection of Tyco Solarlok connectors

153

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Plugs and Sockets

Accessories Art. No.

1302110

1302111

1302112

1302113

1302114

Model Description

Tyco Solarlok manual crimping pliers Universal, without crimphead

Tyco Solarlok crimphead for 4 and 6 mm Go with Tyco Solarlok manual crimping pliers

Tyco Solarlok press-out tool For dismantling of Solarlok male/female

Tyco Solarlok support protection

Tyco Solarlok service case

For all solar cables with 100 cable coupler / 1.5 / 2.5 / 4.0 / 6.0 mm crimp contacts, incl. tools

154

Tyco Solarlok connectors 4 mm

Tyco Solarlok connectors 6 mm

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

155

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Fitting Tool

Rennsteig Tools Solar Tools for Cutting, Stripping and Crimping


Rennsteig Werkzeuge GmbH this company in the community of Viernau/Thuringia (Germany) follows a long tradition of hand tools development and manufacture in this region. Based on this experience the Rennsteig Werkzeuge GmbH, since 1991 a subsidiary of Knipex Werk, was founded. design and good handling of these pliers rest on the ergonomical design of the two-component handles.

Crimping system pliers

Cable shears

The forged cable shears are universally deployable for cutting, stripping and peeling of cables with diameters of up to 50 mm. The sharp, hardened blades with precision grinding ensure easy and clean cuts, using only one hand. Crushing and distortion of cable conductors and insulation are avoided.

The crimping pliers PEW 12 are recommended for crimping of solar contacts of almost all connector systems. Crimping can ensure the exact electrical connection without soldering. The excellent handling, easy exchange of the crimping insert bits and the possibility of adding a positioning aid are facts in favour of these crimping pliers.

Pro Kit

Insulation stripping pliers


156

These special pliers with length stop are perfect for high-quality and damage-free stripping and peeling. During stripping the cable is not crushed or distorted. The exchangeable knives allow working with cables of diameters of 1.5 6 mm as standard. The compact

The practical plastic case of the Pro Kit contains cable shears, stripping pliers and crimping pliers (one of each). Thus the Pro Kit enables almost all jobs associated with cables and connectors. As standard, the Pro Kit is equipped with crimping insert bits and locators (positioning aids) for MC3, MC4, Tyco and Yukita. Additional insert bits are available as options.

The Rennsteig Pro Kit contains cable shears, stripping pliers and crimping pliers (one of each), suitable for MC3, MC4, Tyco and Yukita.

The Rennsteig crimping pliers PEW 12 are suited for various connector systems, due to their different crimping insert bits.

................................................................................................................................................................... ...................................................................................................................................................................
Fitting Tool ACCESSORIES

Art. No.

1302150

1302149

1302135

1302142

Model Description Dimensions (L / W / H) Weight Warranty Norms Accessories Art. No.

Rennsteig cable shears D15 (1.5 - 50 mm) Cable shears with cutting width of up to 50 mm 170 mm / 110 mm / 20 mm 240 g 2 years -

Rennsteig stripping pliers (1.5 6 mm) Pliers for solar cables of 1.5 6 mm 200 mm / 110 mm / 20 mm 425 g 2 years -

Rennsteig crimping pliers PEW 12 Crimping pliers for various insert bits 200 mm / 110 mm / 20 mm 620 g 2 years DIN 60352-2, DIN 41641

Rennsteig Pro Kit to MC3, MC4, Tyco and Yukita Flexible case for everything to do with solar cables 340 mm / 275 mm / 83 mm 1300 g 2 years DIN 60352-2

1302136

1302137

1302138

1302139

Model Dimensions (L / W / H) Weight Warranty Norms Art. No.

Rennsteig crimping insert to MC3 and Yukita 38 mm / 33 mm / 12 mm 50 g 2 years DIN 60352-2 1302140

Rennsteig locator to MC3 and Rennsteig crimping insert to Yukita MC4 39 mm / 39 mm / 29 mm 32 mm / 32 mm / 12 mm 20 g 50 g 2 years 2 years DIN 60352-2 DIN 60352-2 1302141 1302147

Rennsteig locator to MC4 39 mm / 39 mm / 29 mm 20 g 2 years DIN 60352-2 1302151

157

Model Dimensions (L / W / H) Weight Warranty Norms

Rennsteig crimping insert to Tyco 32 mm / 32 mm / 12 mm 50 g 2 years DIN 60352-2

Rennsteig locator to Tyco 39 mm / 39 mm / 29 mm 20 g 2 years DIN 60352-2

Rennsteig crimping insert to Huber+Suhner 4 - 6 mm 32 mm / 32 mm / 12 mm 50 g 2 years DIN 60352-2

Rennsteig crimping insert to Hirschmann 2.5 - 6 mm 32 mm / 32 mm / 12 mm 50 g 2 years DIN 60352-2

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Lightning Protection

Phoenix Contact surge protection Lightning protection concepts for PV systems


Surge protection devices
Surges, caused by lightning strikes or switching actions, are frequently the cause of damages and failures in electrical equipment. Inverter failures mean cost-intensive equipment damages. Yield losses and repair costs are consequences, which can be prevented by surge protection devices.

Direct and indirect lightning protection

Protection circuit devices

Direct (exterior) lightning protection must be implemented by observing the protection zones and galvanic separations by means of lightning rods for the PV generator. For indirect (interior) lightning protection, several Phoenix Contact products are available, which should be installed directly before the devices to be protected (or at the lightning protection zone transitions).

Surge protection devices must be considered for all circuits: On the DC side between L+, L- and the earth potential, and on the AC side between the phases L1, L2, L3, the neutral wire and the earth potential. In addition, all other circuits (e.g. data and measuring technology circuits), which are connected to the inverter, must be protected with suitable products. 158

Features of the PV SETS


n n n n n

Surge protection for the DC side Optional: Surge protection for the AC side IP65 housing Plug-in PV SET DC with MC4 For one string as standard, optional multi-string available PE pins for a minimum of 6 mm connection to potential equalisation

The PV SET 1000DC is equipped with plug-in MC4 connectors and ideally suited for lightning and surge protection of individual PV strings.

The PV SET 1000DC/AC can provide protection against surges in PV strings and AC outputs of single-phase inverters.

................................................................................................................................................................... ...................................................................................................................................................................
Lightning Protection ACCESSORIES

Art. No.

1302156

1302157

1302158

1302159

1302160

Model Surge protection Max. DC open circuit voltage Max. DC permanent voltage (LPE) Rated voltage AC Max. AC permanent voltage (LN / N-PE) Max. pre-fuse Rated current Nominal lightning discharge current (8/20) s (L-N / N-PE) Max. lightning discharge current (8/20) s Lightning testing current (10/350) s Protection level (L-N / N-PE) Response time (L-N / N-PE) Cable connection (rigid / exible) Protection mode Dimensions (L / W / H) Weight Warranty Norms

Phoenix Contact VALMS 1000DC/2+V-FM DC, 1 string 1000 V 1000 V 80 A 15 kA 30 kA < 5 kV < 25 ns 0.5 - 35 mm / 0.5 25 mm IP20 - / 52.5 mm / 367 g 2 years IEC protection class II, EN-Type T2

Phoenix Contact PV SET Phoenix Contact PV SET 1000DC, PV string 1000DC/AC, PV string & AC DC, 1 string AC and DC, 1 string 1000 V 1000 V 1000 V 1000 V 30 A 15 kA 30 kA < 5 / - kV < 25 ns MC4 IP65 125 mm / 200.0 mm / 122 mm 1217 g 2 years IEC protection class II, EN-Type T2 335 / 260 V 125 A 80 A 15 kA 30 kA < 5 / 1.5 kV < 25 ns 0.5 - 35 mm / 0.5 25 mm IP65 200 mm / 200.0 mm / 122 mm 1523 g 2 years IEC protection class II, EN-Type T2

Phoenix Contact PV SET Phoenix Contact FLT-CP5ST/600DC PLUS-3S-350, AC 3~, type 1 DC, max. 5 strings AC 600 V 600 V 30 A 20 kA 40 kA < 3.6 / - kV < 25 ns 0.5 - 35 mm / 0.5 25 mm IP65 300 mm / 300.0 mm / 142 mm 3410 g 2 years IEC protection class II, EN-Type T2 240 V 350 / 350 V 315 A 25 / 100 kA 100 kA < 1.5 / 1.5 kV < 100 / 100 ns 2.5 - 35 mm / 2.5 25 mm IP20 - / 142.8 mm / 1748 g 2 years IEC protection class I, EN-Type T1, IEC 61643-1 / EN 61643-11

159

Continued on next page

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

...................................................................................................................................................................

Lightning Protection

Art. No.

1302161

1302162

1302163

1302164

1302165

Model Surge protection Max. DC open circuit voltage Max. DC permanent voltage (LPE) Rated voltage AC Max. AC permanent voltage (LN / N-PE) Max. pre-fuse Rated current Nominal lightning discharge current (8/20) s (L-N / N-PE) Max. lightning discharge current (8/20) s Lightning testing current (10/350) s Protection level (L-N / N-PE) Response time (L-N / N-PE) Cable connection (rigid / exible) Protection mode Dimensions (L / W / H) Weight Warranty Norms

Phoenix Contact VALPhoenix Contact VALPhoenix Contact DTCP-3S-350, AC 3~, type 2 CP-1S-350, AC 1~, type 2 LAN-CAT.6+, Ethernet AC 240 V 350 / 264 V 125 A 60 / 20 kA 120 / 40 kA < 1.4 / 1.5 kV < 25 / 100 ns 2.5 - 25 mm / 2.5 16 mm IP20 - / 49.2 mm / AC 240 V 350 / 264 V 125 A 20 / 20 kA 40 / 40 kA < 1.4 / 1.5 kV < 25 / 100 ns 2.5 - 25 mm / 2.5 16 mm IP20 - / 25.3 mm / Ethernet data circuit 3.3 V 1.5 A 0.1 / 2 kA < 0.009 / 0.7 kV < 1 / 100 ns RJ45

Phoenix Contact DTTELE-RJ45, Analogue & ISDN Analogue & ISDN data circuit 130 V 185 V 0.38 A 5 / 5 kA 10 kA < 0.25 / 0.25 kV < 100 / 100 ns RJ45, 0.14 - 1.5 mm IP20 102 mm / 25.0 mm / 65 mm 333 g 2 years IEC protection class / ENType B2, C2, C3, D1, IEC 61643-21

Phoenix Contact Plugtrab PT, sensor system Sensor system 12.8 V 9V 2A 0.69 / 10 kA 20 kA 2.5 kA < 0.018 / 0.45 kV < 1 / 100 ns 0.2 - 4 mm / 0.2 2.5 mm IP20 - / 17.5 mm / 653 g 2 years IEC protection class / ENType C1, C2, C3, D1, IEC 61643-21

160

IP20 102 mm / 25.0 mm / 65 mm 416 g 226 g 329 g 2 years 2 years 2 years IEC protection class II, IEC protection class / ENIEC protection class II, EN-Type T2, IEC 61643-1 EN-Type T2, IEC 61643-1 Type B2, C2, D1, IEC / EN 61643-11 61643-21 / EN 50173-1 / EN 61643-11

The PV SET 5ST/600DC is suited for up to 5 strings with a maximum voltage of 600 V DC each, which can be connected directly by means of terminals.

1. Phoenix Contact VAL-MS 1000DC/2+V-FM 2. Phoenix Contact PV SET 1000DC, PV string 3. Phoenix Contact PV SET 1000DC/AC, PV string & AC 4. Phoenix Contact PV SET 5ST/600DC 5. Phoenix Contact FLT-CP-PLUS-3S-350, AC 3~, type 1 6. Phoenix Contact VAL-CP-3S-350, AC 3~, type 2 7. Phoenix Contact VAL-CP-1S-350, AC 1~, type 2 8. Phoenix Contact DT-LAN-CAT.6+, Ethernet 9. Phoenix Contact DT-TELE-RJ45, Analogue & ISDN 10. Phoenix Contact Plugtrab PT, sensor system

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

161

Complete Systems
The TRITEC complete systems and Ecolights lighting systems are a combination of individual components that are specially coordinated. This ensures the simple design of ideal stand-alone energy systems.

ECOLIGHTS TRITEC

163

...................................................................................................................................................................
COMPLETE SYSTEMS

...................................................................................................................................................................

Stand-alone System Kits

Ecolights The innovative solar lighting systems


Sustainability, quality and design
Sustainability, quality and design are common features of Ecostar Standard, Ecostar with glass module and Double-Sol. They are ideally suited for housing areas, public squares, building entrances, foot and cycle paths, bridges, parks, gardens, playgrounds and camping sites, water fronts, bus stops, leisure and sport facilities. 8 hours of operation per day. The lights switch on automatically at nightfall for 6 hours and for 2 hours at dawn.

Double-Sol

Ecostar

164

The cylindrical light made of high-quality plastic and the slightly curved special laminate module of the Ecostar combine design and functionality. The model with glass module blends into any surroundings and provides intriguingly simple looks. The solar modules, adjustable by 360, can be optimally adjusted to any environment. With their operation period of more than 50000 hours, the used LED illuminants are not only energy saving, but also extremely long-lasting and efcient. The Ecostar lights are designed for

The ecological lighting option Double-Sol combines innovative solar technology and contemporary wood design. In addition to the features of the Ecostar models, the Double-Sol has a LED night light between its two wooden masts, thus creating an attractive mood, showing off the innovative design and combining aesthetics and functionality.

Advantages in brief
n n n n n n

Absolutely maintenance-free Long-lasting Quick and easy installation Innovative design No electricity costs No wiring expenses

The solar street light Ecostar Standard is specically suited for installations without grid connection.

Photometric features of the Ecolights.

................................................................................................................................................................... ...................................................................................................................................................................
Stand-alone System Kits COMPLETE SYSTEMS

Art. No.

1100120

1100121

1100122

Model Total height Lens height Material Solar module Maintenance-free solar gel battery Luminous ux of LED illuminants Operation period Weight incl. base console Warranty Norms

Ecostar Standard 4.1 m 3.3 m Aluminium 60 Wp 48 Ah 1100 lm > 8 hours 56 kg 2 years CE mark

Ecostar with LSG glass module 4.2 m 3.3 m Aluminium / glass 58 Wp 48 Ah 1100 lm > 8 hours 62 kg 2 years CE mark

Double-Sol 4.0 m 3.3 m Aluminium / wood 60 Wp 54 Ah 1200 lm > 8 hours 92 kg 2 years CE mark

165

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
COMPLETE SYSTEMS

...................................................................................................................................................................

Stand-alone System Kits

TRITEC Off-Grid Kits The smart packages in sizes XS XXL


Where there is no grid connection, solar stand-alone systems often provide the ideal solution to supply consumers with energy efciently. Stand-alone energy systems can for example be used for garden sheds, weekend or holiday homes; in regions that are too far away from the grid, even complete villages are equipped with so-called "Solar Home Systems". Compared to conventional diesel units, the solar systems offer some essential benets, for example the running costs for fuel can be omitted.

Solar stand-alone systems

conditions and ensure gentle charging and discharging of batteries. The Hoppecke batteries are special solar batteries that offer a higher number of cycles compared to normal lead batteries.

Stand-alone inverters

Solar generator, charge controller and battery

If solar stand-alone systems are to be supplied simultaneously with major 230 V consumers, a stand-alone inverter must be part of the complete system as well. The Kaco stand-alone inverters convince with their high level of efciency, due to the HF transformer topology and easy operation via an integrated LCD display.

166

The three components solar generator, charge controller and battery are the core of every solar stand-alone energy system. For the solar generator, the use of stand-alone modules of Kyocera is recommended; they deliver exactly that voltage required to charge the battery. The charge controllers of Morningstar are globally used in even the most adverse climate

Features
n n n n n n

3 small Off-Grid Kits (XS, S, M) for 12 V DC consumers 3 large Off-Grid Kits (L, XL, XXL) for 230 V consumers Special stand-alone modules of Kyocera Sturdy charge controllers of Morningstar Cycle-proof batteries of Hoppecke Efcient stand-alone inverters of Kaco

Solar stand-alone energy systems consist of a solar generator (modules), an internal control (charge controller), an energy storing unit (battery) and, if required, an energy converter (stand-alone inverter).

The Kyocera stand-alone modules' electrical parameters are specically designed for the use in stand-alone systems.

................................................................................................................................................................... ...................................................................................................................................................................
Stand-alone System Kits COMPLETE SYSTEMS

Art. No. Model Modules Module output Module rated voltage Module rated current Cable set module/charge controller

1100114 TRITEC Off-Grid Kit XS 1 x KD50SE-1P 50 Wp 17.9 V 2.80 A 2 x 10 m Radox 4 mm, 4 cable end sleeves

Charge controller System voltage Load current Cable set charge controller/battery

Battery Battery capacity (10 h) Stand-alone inverter Dimensions (L / W / H) Weight Warranty

1100119 TRITEC Off-Grid Kit XXL 4 x KD135SX-1PU 540 Wp 35.4 V 15.26 A 4 x 2 m Radox 4 mm, 2 x 10 m Radox 4 mm, 12 cable end sleeves Morningstar SHS-6 Morningstar SHS-6 Morningstar SHS-10 Morningstar SHS-10 Morningstar ProMorningstar TriStar Star-15 - 45 12 V 12 V 12 V 12 V 12 V 24 V 4.25 A 6.00 A 10.00 A 10.00 A 15.00 A 45.00 A 2 x 2 m Radox 2 x 2 m Radox 2 x 2 m Radox 2 x 2 m Radox 2 x 2 m Radox 2 x 2 m Radox 10 mm, 4 cable 4 mm, 4 cable end 4 mm, 4 cable end 4 mm, 4 cable end 6 mm, 4 cable end 10 mm, 4 cable end sleeves, sleeves, 1 battery end sleeves, sleeves, 1 battery sleeves, 1 battery sleeves, 1 battery terminal fuse 50 A terminal fuse 50 A terminal fuse 50 A terminal fuse 50 A 1 battery terminal 1 battery terminal fuse 100 A, battery fuse 100 A terminal clip with cable clip (+ / ) Hoppecke power. Hoppecke power. Hoppecke power. 4 x Hoppecke 2 x Hoppecke 2 x Hoppecke com SB 12V 60 com SB 12V 100 power.com SB 6V power.com SB 6V com SB 12V 130 power.com SB 6V 220 220 220 63 Ah 95 Ah 129 Ah 220 Ah 220 Ah 220 Ah Kaco KI 250 - 12 V Kaco KI 1000 - 12 V Kaco KI 2000 - 24 V 530 mm / 660 mm / 1010 mm / 660 mm / 1430 mm / 660 mm / 1010 mm / 660 mm / 1430 mm / 660 mm / 1430 mm / 660 mm / 294 mm 292 mm 325 mm 577 mm 753 mm 1183 mm 22.6 kg 34.4 kg 54.3 kg 73.0 kg 105.0 kg 202.0 kg 2 years 2 years 2 years 2 years 2 years 2 years

1100115 TRITEC Off-Grid Kit S 1 x KD95SX-1P 95 Wp 17.9 V 5.31 A 2 x 10 m Radox 4 mm, 4 cable end sleeves

1100116 TRITEC Off-Grid Kit M 1 x KD135SX-1PU 135 Wp 17.7 V 7.63 A 2 x 10 m Radox 4 mm, 4 cable end sleeves

1100117 TRITEC Off-Grid Kit L 2 x KD95SX-1P 190 Wp 17.9 V 10.62 A 1 x 2 m Radox 4 mm, 2 x 10 m Radox 4 mm, 6 cable end sleeves

1100118 TRITEC Off-Grid Kit XL 2 x KD135SX-1PU 270 Wp 17.7 V 15.26 A 1 x 2 m Radox 4 mm, 2 x 10 m Radox 4 mm, 6 cable end sleeves

167

The generated solar energy is efciently temporarily stored in the extremely cycle-proof batteries of Hoppecke.

The Kaco stand-alone inverters of the Kits L, XL and XXL reliably deliver alternating current, thus allowing for the connection of all major 230 V consumers.

TRITEC Group www.tritec-energy.com | 20100512-1 | The content of this datasheet is subject to change without prior notice

Customer Support and Services


Supported in every aspect: We not only plan and calculate photovoltaic systems of all sizes, we also offer photovoltaic insurance upon request. Our web site offers you our product software, documentations and brochures. In addition, we regularly provide training courses.

169

Product Software
Product software, which helps you in the selection of the products, is available on our web sites Product Software section or on the relevant product web site. Product software is available for the dimensioning of your mounting system, both for the proprietary TRITEC mounting systems TRI-STAND and TRI-VENT, as well as for the Solrif roof-integrated system. The dimensioning software TRI-DESIGN allows for our PV mounting systems TRI-STAND and TRI-VENT to be designed quickly and easily. The dimensioning software TRI-DESIGN for PV mounting systems: allows the dimensioning of PV mounting systems with just a few clicks; takes into account the characteristics of the respective roof and used solar modules; finally, the programme automatically creates a bill of materials, which can be exported, edited and sent. For our characteristics analyser TRI-KA, the TRITEC product for checking the output of installed solar modules, there is the TRI-KA product software. The TRI-KA software can compare the target output of the solar system with its actual output and display the result. Both operation and performance of our TRI-KA, including the TRI-KA software, have been essentially enhanced in time for the Intersolar 2010. For the TRI-KA software this means: Intuitive operation, even without prior knowledge! Dimensioning software for inverters calculates suitable inverters for your solar modules, dependent on site, orientation and slope. In addition to the actual inverter dimensioning, customer-compatible project overviews, including energy yield, can be created. Inverter dimensioning software is available for different TRITEC inverters: Danfoss, SMA and Kaco.

171

The dimensioning software TRI-DESIGN allows us to design the system optimally for the individual roof and thus to select the best version of the mounting system.
TRITEC International AG

The TRI-STAND dimensioning software TRI-DESIGN calculates and designs the mounting systems TRI-STAND and TRI-VENT according to the standards of DIN 1055*. The relevant directives are DIN 1055-4* for wind loads and DIN 1055-5* for snow and ice loads, which affect the photovoltaic system and its substructure.
TRITEC International AG

Dimensioning software TRI-DESIGN

European standard: EN 1991-1-3

Training Courses
We regularly offer product training courses and workshops. You will find the current training dates, subjects and venues on our web site: www.tritec-energy.com/training TRI-KA II: Easy and quick output checking of installed solar modules Our characteristics analyser TRI-KA, the TRITEC product for checking the output of installed solar modules, is precisely tailored to todays and future requirements of PV installers. By analysing the characteristics, the solar systems output can be measured during the installation, handover or maintenance of the system and compared with the target output. Working with the characteristics measuring device TRI-KA could not be more efficient: The device is extremely easy to operate and extraordinarily flexible and versatile thanks to its technical enhancements. This training course informs you about all the typical output reducing factors of photovoltaic systems, characteristics analysis and the measuring procedure with the characteristics analyser TRI-KA II.

Our special training offerings for 2010


Mounting systems TRI-STAND and TRI-VENT in practice: an intensive training course with guarantee benefits Design the mounting systems TRI-STAND and TRI-VENT quickly and safely: This intensive training course teaches you all you need to know about roofs, load effects and statics and gives you the opportunity to apply the gained knowledge in practice: with the mounting systems TRI-STAND and TRI-VENT and the dimensioning software TRI-DESIGN. Extension of manufacturers guarantee: All installers, who successfully attended a TRI-STAND and TRI-VENT intensive training course, will receive a guarantee extension for TRI-STAND and TRI-VENT of an additional 5 years to 10 years in total.

Product Documentations and Brochures


Our download section offers product documentations, declarations of conformity, installation instructions and guarantee terms for all our products. In addition to our product catalogue, our company brochure is available. On our web site as download or you may order it from: +41 61 699 35 55 (International Headquarters, Switzerland).

173

Training Centre France, Montpellier

Reference Cases
We meet the highest quality demands in different areas. Thanks to our high-quality products and our long years of experience, we have the ideal solution for every requirement: Photovoltaic solutions made to measure.

175

Stade de Suisse, Bern (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer
Stade de Suisse The worlds largest roof-integrated solar power plant on a football stadium.

Operator

1.35 MWp 5,122 units Kyocera KC167GH-2 2,808 units Kyocera KC175GHT-2 7 units SolarMax 125 4 units SolarMax 100C Alufix 567 tons 1,134,045 kWh/year 18th March 2005 (855 kWp) 9th August 2007 (491 kWp) TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg BKW FMB Energie AG

IKEA AFG Arena, St. Gallen (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 202.4 kWp 1,012 units Kyocera KC200GHT-2 SolarMax 80C and 100C AluTec CF (flat roof Halfen) 95 tons 190,250 kWh/year 13th August 2007 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Municipal Utility St. Gallen

The photovoltaics system on the flat roof of the IKEA AFG Arena ensures CO2 savings of 95 tons/year.

176

Rental Flat Complex Eulachhof, Winterthur (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
Swiss Solar Award 2007 The zero energy residential development is architecturally and energetically noteworthy.

176 kWp 880 units Kyocera KC200GHT-2 2 units SolarMax 80C AluTec CF (flat roof Halfen) 92 tons Approx. 164,000 kWh/year 26th June 2007 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Profond Contract Collective / Allianz Suisse Life Insurance Company

Factory Frigel Firenze S.p.A., Florence (Italy)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 175.6 kWp 878 units Kyocera KC200GHT-2 2 units SolarMax 50C 1 unit SolarMax 80C AluTec CF 122 tons 230,000 kWh/year 9th May 2008 TRITEC Group TRITEC Italia s.r.l. Frigel Firenze S.p.A.

Flat roof, shed roof and facades The photovoltaics system was installed on different surfaces.

Window Factory Nauer, Samstagern (Switzerland)


Installed power Solar modules Inverters 123.62 kWp 567 units Kyocera KD205GH-2P 1 unit SolarMax 100C (flat roof) 1 unit SolarMax 3000S, 2 units SolarMax 2000S (front) AluStand (flat roof) TRI-VENT (front) 56.1 tons Approx. 112,128 kWh/year 14th November 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Sanjo Green AG, Altendorf

Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer
Quick assembly on front and roof: No problem with TRI-VENT and AluStand.

Operator

Department Store La Trocha, Malaga (Spain)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer 103.73 kWp 506 units Kyocera KD205GH-2P 1 unit SolarMax 100C Own construction 83 tons 165,968 kWh/year September 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg; TRITEC Trienergy Technology S.L. | Espaa Solarwind Invest Spain, S.L.

177

Thanks to ideal South-facing and inclination, the system provides the best possible energy output.

Operator

Novartis Gehry Building, Basel (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer
The system, integrated into the building exterior, ensures solar energy and good looks for the architectural jewel.

Operator

92.74 kWp (7 sub-systems) Schco & Sunways 7 units Fronius Integration into the building exterior of Josef Gartner GmbH 32.5 tons Approx. 65,000 kWh/year 13th November 2008 TRITEC Group Baumgartner GmbH, Germany TRITEC AG | Schweiz Zweigniederlassung Aarberg Novartis

Sulzer II, Zrich (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 79.2 kWp 396 units Kyocera KC200GHT-2 2 units SolarMax 35C AluStand (Kalzip) 42 tons Approx. 75,240 kWh/year 30th July 2007 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Alteno Contracting AG

An area of 558.65 m2 generates electricity for 21 average households.

178

Farmer Johann Schild, Hainsacker (Germany)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer
Healthy milk from happy cows and clean energy from quality modules.

Operator

58.31 kWp 343 units Kyocera KC170GHT-2 9 units Kyocera KC5.4i 2 units Kyocera KC3.6i AluStand 38 tons Approx. 54,231 kWh/year 12th July 2005 TRITEC Group TRITEC Deutschland GmbH K&S Solar Systeme GmbH & Co.KG, Regensburg Farmer Johann Schild

Technical Centre Holligen, Bern (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
The quality of the photovoltaic installation is assured by the string current monitoring using a datalogger.

55.6 kWp 278 units Kyocera KC200GHT-2 SolarMax 30C & SolarMax 20C AluStand (flat roof) 26.5 tons Approx. 51,700 kWh/year 13th July 2007 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Energie Wasser Bern

School Building Breite, Herrliberg (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
Advantageous location Due to the view of the lake, not only vines enjoy stronger solar irradiation.

39.69 kWp 189 units Kyocera KD210GH-2P 4 units SMA SMC 9000TL AluStand 18.7 tons Approx. 37,308 kWh/year 14th October 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Herrliberg municipality

Secondary School Building, Langnau i. E. (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
Good teamwork: Solar modules and inverters brave all weather conditions.

179

30.24 kWp 144 units Kyocera KD210GH-2P 6 units SolarMax 6000S AluStand 14.6 tons Approx. 29,100 kWh/year 28th November 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Energie Plus, Langnau

Farm Klti, Zrich (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 30.24 kWp 168 units Kyocera KD180GH-2P 6 units TRI-Xi 5.4 MV AluStand 14.2 tons Approx. 28,425 kWh/year 14th October 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg The Klti Family, Zrich

Profitable surfaces: Solar power is generated on two roofs.

Agricultural Enterprise, Hautes Alpes (France)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Technical support Planner / Installer Operator 29 kWp 162 units SolarWorld Sunmodule+ SW 180 mono 3 units SMA SMC 9000TL 1 unit SMA SB 1100 Roof integration 12 tons Approx. 34,800 kWh/year Summer 2008 TRITEC Group TRITEC France SARL LuberonSolaire Agricultural enterprise

The original asbestos roof could be fully replaced by the roof-integrated system.

180

Detached Family House, les Landes (France)


Installed power Solar modules Inverters 22.8 kWp 176 units Kyocera FC130GX-2P 1 unit SMA SMC 9000TL 1 unit SMA SMC 6000TL 1 unit SMA SB 5000TL-20 1 unit SMA SB 1700 Solrif 8.8 tons Approx. 20,000 kWh/year Summer 2009 TRITEC Group TRITEC France SARL EcoSysteo Private operator

The 23 kWp system covers the roof completely and is perfectly integrated into its surroundings.

Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator

ISES SolarCarport, Freiburg i.Br. (Germany)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
SolarCarport The laminates, in combination with Solrif, form the vapour barrier.

14.04 kWp 108 units Kyocera FL130T-1A 2 units Kyocera KC5.4i 1 unit Kyocera KC1.8i Solrif 8.2 tons Approx. 12,635 kWh/year March 2007 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg ISES (International Solar Energy Society)

Solar Power Plant, Jungfraujoch (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 11.6 kWp 58 units Kyocera KC200GHT-2 4 units SolarMax 3000S Facade system, own construction 8.1 tons Approx. 16,250 kWh/year Winter 2007/2008 TRITEC Group sol-E Suisse AG BKW FMB Energie AG

Top of Europe The highest solar power plant in the world.

Detached Family House Eberenz, Biel-Benken (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer
The photovoltaic system comprises the west, east and south side of the pyramidal broach roof.

181

Operator

9.25 kWp 35 units MegaSlate 136 W 51 units special modules 2 units SolarMax 4000C 1 unit SolarMax 3000S MegaSlate 3S (roof integration) 3.8 tons Approx. 7,600 kWh/year 20th June 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg The Eberenz Family, Biel-Benken

Detached Family House Neuffer, Deckenpfronn (Germany)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Technical support Planner / Installer Operator
Aesthetics and photovoltaics go well together.

9.23 kWp 45 units Kyocera KD205GH-2P 1 unit TRI-Xi 10.0 TRI-STAND 6.5 tons Approx. 9,300 kWh/year 30th July 2009 TRITEC Group TRITEC Deutschland GmbH Elektro Walz, Deckenpfronn E. Neuffer

Detached Family House, Falkenstein (Germany)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Technical support Planner / Installer Operator
Attractive Kyocera PV system; easily and safely installed with the TRI-STAND mounting system.

7.35 kWp 35 units Kyocera KD210GH-2PU 1 unit SolarMax 4200S 1 unit SolarMax 3000S TRI-STAND 2.9 tons Approx. 5,950 kWh/year 14th July 2009 TRITEC Group TRITEC Deutschland GmbH FAMOS Private operator

182

Detached Family House Hopman, Mahlberg (Germany)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 6.72 kWp 32 units Kyocera KD210GH-2PU 2 units SMA SB 3000TL-20 TRI-STAND 4.6 tons 6,552 kWh/year 1st June 2009 TRITEC Group TRITEC Deutschland GmbH The Hopman Family, Mahlberg

The Plus energy of the solar system brings double benefits: in ecological as well as economical terms.

Petrofer AG, Reinach (Switzerland)


Installed power Solar modules 6 kWp 16 units Kyocera KC175GHT-2 (front) 16 units Kyocera KC200GHT-2 (flat roof) 2 units SolarMax 3000S AluStand 2.8 tons Approx. 5,630 kWh/year 16th May 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg Petrofer AG, Reinach

Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer
Each surface can be used be it roof or front.

Operator

Detached Family House, Rti (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
A nice view and a large electricity yield are certain for the detached family house.

5.95 kWp 35 units Schott Solar ASE 165-GT-FT/MC 170 Wp 2 units SolarMax 3000S AluStand 2.9 tons Approx. 5,900 kWh/year 10th July 2008 TRITEC Group LEAB AG Qualified installer of TRITEC AG | Schweiz Private operator

Farmer H. Bauer, Gechingen (Germany)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator 5.7 kWp 60 units Schott ASI 95 1 unit SMA SMC 5000A TRI-VENT 3.8 tons 5,415 kWh/year July 2009 TRITEC Group TRITEC Deutschland GmbH Elektro Walz, Deckenpfronn Farmer H. Bauer

183

Securing without screws: The new trapezoidal sheet system TRI-VENT.

Tracker, Wilchingen (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 5.44 kWp 32 units Schott Solar Schott Poly 170 2 units SolarMax 3000S Biaxial tracker from SolarTrack 3.6 tons Approx. 7,200 kWh/year 1st December 2008 TRITEC Group Solarbau Lowel GmbH Private operator

Thanks to automatic biaxial tracing, the tracker produces up to 35 % more power.

Detached Family House, Bad Sobernheim (Germany)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
The sun over the Rhineland Palatinate provides good wine and high solar gain.

4.59 kWp 27 units Schott Solar Schott Poly 170 SMA SB 4000TL-20 AluStand 2.9 tons 4,360 kWh/year 18th August 2008 TRITEC Group SolarCelsius OHG Private operator

184

Garage Building Christ, Biel (Switzerland)


Installed power Solar modules Inverters Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 4.31 kWp 21 units Kyocera KD205GH-2P 2 units SolarMax 2000S AluStand 1.9 tons Approx. 3,810 kWh/year 11th June 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg The Christ Family, Biel

Beautiful views and strong solar irradiation: There is more than just one benefit to be gained from the garage roof.

Detached Family House Suter, Meilen (Switzerland)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator
Ideal location: At Lake Zurich increased solar irradiation is guaranteed.

3.96 kWp 18 units SolarWorld Sunmodule+ SW 220 poly 1 unit SolarMax 4000C AluStand 1.8 tons Approx. 3,566 kWh/year 28th April 2008 TRITEC Group TRITEC AG | Schweiz Zweigniederlassung Aarberg The Suter Family, Meilen

Detached Family House, Saint-Hippolyte (France)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator
The roof-integrated photovoltaics system blends in idyllically with its surroundings.

3 kWp 18 units SolarWorld laminates SW 170 Wp SolarMax 3000S SolarWorld energy roof 1.2 tons Approx. 3,500 kWh/year March 2008 TRITEC Group TRITEC France SARL SARL Solaire du Roussillon Private operator

Detached Family House, Verdun-en-Lauragais (France)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator
A typical detached house: 3,500 kWh/year corresponds to the yield of the average household.

185

2.97 kWp 18 units SolarWorld Sunmodule+ SW 165 mono 1 unit SolarMax 3000S SolarWorld energy roof 1.2 tons 3,543 kWh/year February 2009 TRITEC Group TRITEC France SARL Phoebus Energies Private operator

Detached Family House, Provence (France)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator
Optimal roof integration: The SolarWorld energy roof.

2.72 kWp 16 units SolarWorld Sunmodule+ SW 170 mono 1 unit SMA SB 2500 SolarWorld energy roof 1.1 tons Approx. 3,250 kWh/year August 2009 TRITEC Group TRITEC France SARL Sarl Orcater Private operator

Detached Family House, Roussillon (France)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator
Integrated into the roof and the environment: Close by is one of the most significant ochre deposits in Europe.

2.6 kWp 20 units Kyocera FL130T-1A 1 unit SolarMax 3000S Solrif 3.1 tons 3,380 kWh/year February 2008 TRITEC Group TRITEC France SARL Julien Cayla Consulting Sarl Private operator

186

Detached Family House, Lucca (Italy)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner / Installer Operator 2.4 kWp 12 units Kyocera KC200GHT-2 1 unit SolarMax 3000C AluTec CF 1.6 tons 2,965 kWh/year 21st January 2008 TRITEC Group TRITEC Italia s.r.l. Private operator

Detached family houses use the sun for energy supply.

Detached Family House, Saint Saturnin les Avignon (France)


Installed power Solar modules Inverter Mounting system CO2 savings/year Energy yield Commissioning Distributor Planner Installer Operator
The photovoltaic system is located close to Avignon one of the most beautiful cities of Provence.

2.1 kWp 16 units Kyocera FL130T-1A 1 unit SolarMax 3000S Solrif 1 ton Approx. 2,700 kWh/year December 2008 TRITEC Group TRITEC France SARL Groupement PV Luberon Private operator

Ziteil Pilgrimage Church, Salouf GR (Switzerland)


Installed power Solar modules Battery Mounting system Commissioning Distributor Planner / Installer Operator 1.7 kWp 16 units Kyocera LA721G108 8 days (autonomy period) Own construction February 1996 TRITEC Group TRITEC AG Salouf GR rectory

The remote Ziteil church is provided with power using a stand-alone system.

Wyssen Avalanche Mast, Mattertal (Switzerland)


Installed power Solar modules Battery Mounting system Commissioning Distributor Planner Installer Operator 36 Wp 3 units SunWare 12/1 Approx. 30 days (autonomy period) Own construction 20th November 2007 TRITEC Group AlpuG GmbH Wyssen Seilbahnen AG Tsch municipality

187

The autonomous energy supply of the stand-alone system allows an artificial triggering of avalanches.

General Terms and Conditions by the TRITEC Group for Commerce

1 Scope 1. TRITECs supplies, services and offers shall be exclusively made on the basis of the following Conditions of Sale and Delivery. The once agreed upon Conditions of Sale and Delivery shall also be valid for all future business relations even if they are not once again explicitly agreed upon. Any agreements which are made between the customer and TRITEC for the purpose of the execution of this contract shall be recorded in writing. 2. These conditions shall be considered accepted at the latest upon the receipt of goods or services. TRITECs silence to different provisions by the customer shall not be considered as a consent to the customers conditions; their validity is opposed. Any deviation from TRITECs Conditions of Sale and Delivery shall be considered as a rejection of the order; any receipt of a delivery notwithstanding even subject to reservations shall be considered as consent to TRITECs Conditions of Sale and Delivery. 3. Any agreements between the customer and TRITEC which supplement or modify these General Terms and Conditions shall only be valid if they are agreed upon in writing. 2 Offer and Contract Conclusion 1. TRITECs offers or, respectively, quotations shall be principally non-binding and without engagement, unless explicitly otherwise agreed upon. 2. Decisive shall otherwise be the prices, plus appropriate statutory sales tax, as indicated in TRITECs order confirmation. Additional deliveries and services shall be separately invoiced. 3. Offers by TRITEC refer to the requirements known to us with regard to the specified quantities at the time of tendering or the confirmation regarding material quality, dimensional tolerances and manufacturers conditions. Subsequent changes shall require our explicit consent and entitle us to change the price accordingly. Data in our brochures such as photos, drawings and other specifications are only approximately. Accordingly, they establish neither a quality agreement nor any warranty and shall not be relevant for the contractual provision of the service and delivery item. 4. Drawings, illustrations, dimensions, weights or other performance data shall only be binding if this is explicitly agreed upon in writing. Any illustrations, drawings, calculations and other documents shall remain TRITEC property and may not be transmitted to third parties without explicit consent. This shall also apply for such written documents which are designated confidential. 5. The contract shall only become effective by TRITECs written order confirmation to the customer based on the customers order; this may also be done electronically (via email). 6. The contract shall be concluded with the proviso of correct and on-time delivery to TRITEC by TRITECs suppliers. This shall only apply in the event that TRITEC is not responsible for the non-delivery, in particular, upon conclusion of a congruent covering deal with the supplier. The customer shall be immediately informed about the non-availability of performance. The quid pro quo shall be immediately reimbursed. 7. Upon contract signature, the customer shall agree to use the products only for the purpose of use intended by the manufacturer.

4 Period of Delivery and Service 1. The written form shall be required for delivery periods or due dates which may be agreed upon as binding or non-binding. TRITECs compliance with delivery and performance obligations shall require the prerequisite of the customers on-time and proper performance of obligations. TRITEC shall be entitled at any time to partial deliveries and partial services, unless the partial delivery or the partial service is unsuitable for the customer. 2. Even in case of bindingly agreed upon time limits and due dates, TRITEC shall not be responsible for delivery and performance delays due to force majeure and due to events which make any delivery for TRITEC not only temporarily considerably impaired or impossible this includes, in particular, strike, lock-out, official orders, etc., even if they occur at our suppliers or their subcontractors. This shall entitle TRITEC to postpone delivery or, respectively, performance by the period of impairment, plus a reasonable start-up period or to rescind the contract wholly or in parts because of the part not yet performed. 3. If the obstruction takes more than three months, the customer shall be entitled to rescind the contract with regard to the not yet performed part after having granted a reasonable extension of time. If the delivery or performance period is extended or if TRITEC is released from its obligations, the customer may not derive any damage claims therefrom. TRITEC can only rely on the indicated circumstances if it notifies the customer within a reasonable period of time. 4. As far as TRITEC is responsible for the non-compliance with bindingly promised time limits and due dates or if it is in delay, the customer shall be entitled to a compensation for the delay in the amount of one half percent for every completed week of delay; at maximum, however, to a total of up to five percent of the deliveries and services affected by the delay. Any claims in excess thereof shall be excluded, unless the delay is due to at least gross negligence by TRITEC. 5. If the customer is in delay of acceptance, TRITEC shall be entitled to demand restitution of the damage incurred. Unless already transferred, the risk of accidental deterioration and accidental loss shall pass over to the customer upon the onset of the delay in acceptance. 5 Passage of Risk 1. The risk shall pass to the customer as soon as the shipment has been handed over to the person carrying out the transport or has left our warehouse for the purpose of shipment. If shipment is delayed upon the customers request, the risk shall pass to the customer with the ready-for-shipment note. 2. If personal delivery is not possible due to the absence of the customer or a customers representative, TRITECs agent shall leave the material. The customers risk and duty of care shall begin with the point in time of delivery, even without any personal delivery. 6 Warranty 1. TRITEC shall be notified in writing of objections and complaints regarding deliveries and services within five days after receipt of the shipment, or for turnkey plants within five days after first commissioning. Warranty claims by the customer shall require that customer has properly complied with legally due requirements of examination and giving notice of defects. 2. Insofar as there is a defect of the goods, TRITEC shall be entitled, at its option, to post-performance in the form of a remedy of defects or delivery of new, nondefective goods. In case of a remedy of defects, TRITEC shall be obligated to bear all expenditures required for the purpose of the remedy of defects, in particular the costs of transport, infrastructure, work and material insofar as they do not increase due to the fact that the goods were taken to another location than the place of performance. 3. If post-performance fails, the customer shall be entitled to optionally demand rescission or reduction. 4. If the customer receives deficient assembly instructions, TRITEC shall merely be obligated to deliver faultless assembly instructions; this, however, only if the deficiency in the assembly instructions conflicts with proper assembly. 5. The warranty period shall be one year as of delivery. For consumers, the period of limitation shall be two years as of delivery. In case of an agreement of acceptance, the warranty period shall begin on the day of acceptance of the delivery object. The above shall not apply if the customer had not notified the defect in due time. 6. After expiry of the warranty period, TRITEC grants the performance warranty for modules to the customer according to the manufacturer warranty provided, as far as TRITEC can claim on the manufacturers performance warranty. 7. Guarantees in the legal sense shall only be given by TRITEC if they are explicitly included in the order confirmation and have been designated as a promise of specific properties of the delivery object. 8. Warranty shall be excluded if the customer or a third party charged by the customer has improperly performed work on the delivery object. Any warranty claims shall expire if the customer attaches unauthorized additional devices or

188

3 Prices and Terms of Payment 1. TRITEC shall principally deliver against prepayment. If no prepayment is requested, the payment claim shall become due and payable at the latest with the provision of the delivery for the customer. Partial deliveries shall be paid within the scope of the individual delivery. Payment dates shall be complied with even if the delivery or acceptance of goods is delayed for reasons which TRITEC is not responsible for. Payments may not be reduced or refused due to complaints or unaccepted claims. Any discount deduction shall require a special written agreement. 2. Unless otherwise agreed upon in the order confirmation, prices shall be valid ex manufacturer or TRITEC warehouse, plus costs for packaging, insurance and shipping; these costs shall be separately invoiced. 3. TRITEC shall be entitled to change prices correspondingly if cost reductions or cost increases result, after contract conclusion, especially due to wage settlements or material price changes. This shall be substantiated to the customer upon request. 4. Statutory regulations shall apply regarding the consequences of any default in payment. Without prior notice of default, a penalty interest of 7 % effective as of the payment due date shall be invoiced for receivables which are not paid as agreed. 5. The customer shall only be entitled to offset rights if the customers counterclaims are recognized by declaratory judgment, uncontested, or have been acknowledged by us in writing. Moreover, the customer is entitled to exercise a right of retention insofar as his/her counterclaim is based on the same contractual relationship.

either him/herself or through third parties provides unauthorized interventions and/or repairs on delivery objects without explicit arrangement with TRITEC. 7 Liability 1. TRITEC shall be liable according to the statutory conditions as far as the customer claims damages which are based on intent or gross negligence, including intent or gross negligence by our representatives or vicarious agents. As far as TRITEC is not charged with any intentional or grossly negligent breach of contract, the liability for damages shall be limited to the foreseeable, typically occurring damage or, respectively, excluded by agreement for countries in which this is permitted. 2. However, liability for damages shall be limited in all of the cases to the foreseeable, typically occurring damage, unless such a limitation violates mandatory law. 3. Liability for culpable injury of life, limb or health shall remain unaffected; this also applies for the absolute liability under the Produkthaftungsgesetz (Product Liability Law). 4. As far as liability by TRITEC is excluded or limited, this shall also apply for the personal liability of its executive personnel, workers, employees, representatives and vicarious agents. 8 Reservation of Ownership 1. TRITEC shall reserve ownership in the goods until full payment of the purchase price. As far as permitted by the respectively applicable legal system, TRITEC shall reserve ownership in the goods regarding contracts with companies until the receipt of all payments from the business relationship with the customer. 2. In case of the customers conduct in violation of the contract in particular, in default of payment TRITEC shall be entitled to repossess the goods. This claim for restitution of property shall only be considered a rescission of contract if TRITEC explicitly declares it in writing. After repossession of the goods, TRITEC shall be entitled to their realization; the realization proceeds shall be credited to the customers liabilities minus reasonable costs of realization. 3. The customer shall be obligated to handle the goods with care; in particular, the customer shall be obligated to adequately insure them, at his/her own costs, for their reinstatement value against damage due to fire, water, and theft. If maintenance and inspection work is required, the customer shall carry them out in due time at his/her own costs. 4. In the event of attachment/execution or other interventions by third parties, the customer shall notify TRITEC immediately in writing so that TRITEC can take corresponding defense measures. As far as a third party is unable to reimburse TRITEC for the legal and extrajudicial costs of a defense measure, the customer shall be liable for the loss which we incurred. 5. The customer shall be entitled to further sell the goods in proper business procedures; however, the customer already now assigns to TRITEC all receivables in the amount of the final invoice total (including sales tax) of the TRITEC receivable which he/she accrues from the further sale versus its buyers or third parties, irrespective of whether the goods have been further sold without or after processing. The customer shall remain entitled to collect this receivable even after the assignment. TRITECs right to collect the receivable itself shall remain unaffected thereby. However, TRITEC agrees not to collect the receivable as long as the customer meets his/her payment obligations from the proceeds obtained, is not in default of payment and in particular, as long as no application for the institution of settlement or insolvency proceedings has been made, or as long as there is no payment stop. But if this is the case, TRITEC may demand that the customer discloses to TRITEC the assigned receivables and their debtors, provides all necessary information for the collection, hands over the pertinent documents, and informs debtors (third parties) of the assignment. 6. TRITEC agrees to release the securities to which it is entitled upon the customers request insofar as the realizable value of our securities exceeds the receivables to be secured by more than 10 %; TRITEC shall be responsible for selecting the securities to be released. 7. For leased articles, the customer shall be obligated to return the leased object on-time and in proper, clean and functioning condition. The customer shall accept full liability for any damage due to improper use, or theft, vandalism, accidents or the like. Every customer shall take care on its own for any repairs. If articles are lost which are necessary for the functioning of the leased article, they shall be principally invoiced to the customer. The customer shall take out insurance for the leased articles. 9 Design Changes We reserve the right to make design changes at any time; however, we shall not be obligated to make any such changes even on already delivered products. 10 Secrecy Unless otherwise explicitly agreed upon in writing, the information submitted to

us in connection with orders shall not be considered confidential. 11 Export Any re-export of delivered goods from the territory of the European Union shall be subject to the country-specific export provisions and is possibly not allowed without an official permit. Export of the delivered goods from the territory of the European Union shall require the suppliers written consent; irrespective thereof, the customer shall obtain on his/her own any official import and export permits. The customer shall be responsible for compliance with the pertinent provisions up to the end consumer. 12 Final Provisions 1. These General Terms and Conditions and the entire legal relations between the customer and TRITEC shall be governed by the law at the registered seat of the company where the order has been placed, with the exclusion of the Vienna UN-Convention on Contracts for the International Sale of Goods. 2. Legal venue for any disputes resulting directly or indirectly from the contractual relationship shall be exclusively at the registered seat of the company where the order has been placed. 3. Above, the respectively acting enterprise of the TRITEC Group has been designated as TRITEC. The contracting party shall acknowledge this and agrees that, with this type of designation, the individual enterprises of the TRITEC Group do not trigger any group liability. 4. Should any provision in these General Terms and Conditions or a provision within the scope of other agreements be or become invalid, the validity of any other provisions or agreements shall not be affected thereby. Instead of the invalid provision or to fill a gap, a regulation shall be agreed upon which as far as legally allowed comes closest to what the contracting parties had wanted. 5. The General Terms and Conditions are translated in several languages. The German version shall be ruling in case of any inconsistencies or in case of doubt. General Terms and Conditions by the TRITEC Group for Commerce Issued: October 2008

189

TRITEC Contacts
TRITEC International AG Headquarters Herrenweg 60 4123 Allschwil / Basel, Schweiz P +41 61 699 35 55 F +41 61 699 35 99 info@tritec-energy.com TRITEC Deutschland GmbH Basler Strae 115 79115 Freiburg i. B., Deutschland P +49 761 400 689 22 F +49 761 400 689 90 deutschland@tritec-energy.com TriEnergy GmbH / TRITEC Logistics Boschstrae 2 / 4 71287 Weissach, Deutschland P +49 7044 90379-0 F +49 7044 90379-90 TRITEC Espaa Trienergy Technology S.L. Edifici CIM Valls Oficina 035, Carrer del Calder s/n 08130 Santa Perpetua de Mogoda Barcelona, Espaa P +34 93 560 65 39 F +34 93 574 36 83 spain@tritec-energy.com TRITEC France SARL Parc dActivits de lAroport 55, imp. Jean-Baptiste Say 34470 Prols / Montpellier, France P +33 467 686 464 F +33 499 533 390 france@tritec-energy.com TRITEC AG | Schweiz Herrenweg 60 4123 Allschwil / Basel, Schweiz P +41 61 699 35 35 F +41 61 699 35 99 schweiz@tritec-energy.com TRITEC AG | Schweiz Zweigniederlassung Aarberg Heckenweg 29 3270 Aarberg, Schweiz P +41 32 665 35 35 F +41 32 665 50 33 aarberg@tritec-energy.com TRITEC Italia s.r.l. Via Dei Ghivizzani, 1743 Int.E 55040 Piano di Mommio (LU), Italia P +39 0584 363 535 F +39 0584 363 533 italia@tritec-energy.com TRITEC Belgi TriEnergy GmbH Boschstrae 2 / 4 71287 Weissach, Deutschland P +49 7044 90379-0 F +49 7044 90379-90 j.b@trienergy-world.de TRITEC sterreich In der Au 29 4644 Scharnstein, sterreich P +43 7615 30522 F +43 0584 30295 oesterreich@tritec-energy.com

190

Imprint
TRITEC International AG, a member of TRITEC Group.
TRITEC International AG | Version 20100512

The German version is binding. The content is subject to change without prior notice. The current version is available from www.tritec-energy.com.

www.tritec-energy.com

You might also like