Professional Documents
Culture Documents
NORTHERN REGION
DELHI Tel : (011) 26176263 / 26175927 Fax : (011) 26198749 E-mail : kirby_del@satyam.net.in CHANDIGARH E-mail : chandigarh@hotmail.com JAIPUR E-mail : kirbyjaipur@rediffmail.com NOIDA E-mail : kir_noida@rediffmail.com
EASTERN REGION
KOLKATA Tel : (033) 24755308 / 24742534 Fax : (033) 24742534 E-mail : kirbycal@cal3.vsnl.net.in BHUBANESHWAR Mobile : 098610-65132 E-mail : kirby_bbsr@yahoo.com RANCHI E-mail : kir_ranchi@rediffmail.com GUWAHATI Mobile : 098640 27928 E-mail : kirby_guwahati@indiatimes.com SHILLONG E-mail : kir_shillong@rediffmail.com
Sales Network
Plot No.: 8 to 15, IDA Phase III, Pashamylaram, Medak Dist. - 502 307, Andhra Pradesh, India. Tel: (08455) 226901 / 2 / 3 / 4 Fax: (08455) 226887 / 226919 e-mail: kirby@kirby-india.com Website: www.kirby-india.com
ACCESSORIES
Single-source responsibility Faster Installation Overall Economical Factory-controlled quality (ISO 9001 Certified) Practically maintenance free Upto 90 M clear spans Flexibility in expansion Energy efficient roof and wall systems Earthquake-resistant
LOUVERS
With overlapping blades allowing free air flow. Size is 1 m x 1 m
Gravity type with bird screen and Mechanical control Damper, Standard size is 3000 mm long with a throat opening of 300 mm.
Warehouses Factories Cold Stores Offices, Schools, Hospitals, Site Offices Gas Stations, Bus Shelters, Car Parks Commercial Complexes, Shopping Malls Aircraft Hangars Sports and other recreational facilities
SKYLIGHTS AND WALL LIGHTS
Made of translucent GRP to match Kirby rib and wall panels, with an estimated light transmitting capacity of 60%.
ROOF CURBS
Enclosure for ducts or other roof projections. 2 mm thick glass fibre reinforced polyester fitting Kirby rib roof panels. Available in opening sizes 600 mm, 900 mm and 1200 mm squares.
SEALERS
Sealer for sidelaps, endlaps and self-glashing windows shall be tape of low hardening permanently flexible blend of butyl rubber.
FORD - CHENNAI
SHEETING
KIRBY RIB (KR)
1 2 3 4 5 Top Coat Corrosion Resistant Primer Pre-treatment Zinc or Zinc/Aluminium Coating High strength tensile steel
1 2 3 4 5
Top Coat Corrosion Resistant Primer Pre-treatment Zinc or Zinc/Aluminium Coating High strength tensile steel
Louver
2 3 4
32 mm 25 mm 1000 mm
3 4 5
26 mm 29 mm 59 mm 1000 mm 333.3 mm
24 (610 mm)
Desert Beige
6 (153 mm)
18 (457 mm)
Sun Gold
Skylight
Roof Cladding
Ridge Ventilator
Roof Curb
Autumn Green
Roof Jack
Galvalume/Aluzinc
Rafter
Tile Red
Galvanized
Sidewall Girt
Endwall Column
Eave Strut
Endwall Girt
Purlin
Caribbean Blue
Downspout
Arctic White
Wall Cladding
100 64 16 Y 1
100
10 24 Y
200 OR 250
10 200 OR 250 10 X 10 10 t X
35 200 OR 250
35 16 64 Y
(Sizes: in mm)
Y 10 1
24
48
Y 116
72
C-SECTION
48 BEAM AND COLUMN (BC-3) 24 MULTI-SPAN (MS) Standard Eave height: 3M-8M Std bay spacing: 6M/7.5M/9M Standard Loadings: Live load 0.5/0.6/1.0 KN/M 2, Wind load 0.75/1.0/1.25 KN/M2 The table above is a general guideline on recommended frame types for different widths. Kirby custom-designs each order to the specified type, 60
96
Secondar y structural framing Secondary ve ref er s to purlins, gir ts, ea refer ers girts, eave struts, wind bracing, flang e flange bracing, base angles, c lips and clips other miscellaneous structural par ts. parts.
1. Purlins and girts shall be roll formed Z sections, 200 mm deep with 64mm flanges. Each flange shall have a 16 mm stiffening lip formed at 450 to the flange. 2. Eave struts are 200 mm deep with a 100mm wide top flange, a 116mm wide bottom flange, both are formed parallel to the roof slope. Each flange has a 24 mm stiffener lip.