Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II

FIZICA CONSTRUC
FIZICA CONSTRUC

IILOR
IILOR
Conf. Dr. Ing. Daniel DAN
Curs nr. 1
Universitatea Politehnica din Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
FIZICA CONSTRUC FIZICA CONSTRUC IILOR IILOR
ESTE O STIIN APLICAT CARE STUDIAZ PROPRIETILE HIGROTERMICE, ACUSTICE,
ILUMINATUL N CLDIRI I N COMPONENTELE SALE (ACOPERIURI, FAADE, FERESTRE,
PEREI DESPRITORI ETC).
Curs nr. 1
CERINELE DE BAZ SUNT LEGATE DE ASIGURAREA CONFORTULUI N CLDIRI
REFERITOARE LA IZOLAREA TERMIC, ACUSTIC I CONFORTUL VIZUAL. CONDITIILE DE
CONFORT SUNT IMPUSE DE ASIGURAREA SNTII OCUPANILOR DIN CLDIRE.
CERINELE DE CONFORT SE CORELEAZ CU CERINELE IMPUSE DE ALCTUIREA
ARHITECTURAL, NATURA MATERIALELOR UTILIZATE, PROBLEMELE ECOLOGICE I
ECONOMICE SPECIFICE MATERIALELOR SI TEHNOLOGIILOR UTILIZATE.
Universitatea Politehnica din Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
DOMENIUL ACOPERIT CONINE 3 SUBDOMENII
1. HIGROTERMICA
- CONSUMUL DE CLDUR, CIRCULAIA AERULUI I UMIDITATEA
DIRECIILE SPECIFICE:
-IZOLAREA TERMIC I INERIA TERMIC
- UMIDITATEA, CONDENSUL PE SUPRAFAA INTERIOAR,
CONDENSUL N INTERIORUL ELEMENTELOR DE NCHIDERE
-- PROTECIA CONTRA UMIDITII (PLOAIE, UMIDITATEA
INIIALA, CONDENSUL PE SUPRAFAA INTERIOAR,
CONDESNUL N INTERIORUL ELEMENTELOR DE CONSTRUCII;
- ENERGIA NECESAR I ENERGIA CONSUMAT;
- VENTILAREA CLDIRILOR, CALITATEA AERULUI INTERIOR,
CIRCULAIA AERULUI
Universitatea Politehnica din Timisoara
FIZICA CONSTRUC FIZICA CONSTRUC IILOR IILOR
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
2. ACUSTICA CLDIRILOR
-PROBLEMELE LEGATE DE PROTECIA LA ZGOMOT
N CLDIRE I NTRE CLDIRE I MEDIUL
NCONJURTOR
- IZOLAREA LA ZGOMOT AERIAN I ZGOMOTUL DE
IMPACT LA NIVELUL PEREILOR, PLANEELOR,
FAADELOR I ACOPERIULUI
- IZOLAREA ACUSTIC A CAMERELOR I A
INSTALAIILOR
Universitatea Politehnica din Timisoara
FIZICA CONSTRUC FIZICA CONSTRUC IILOR IILOR
DOMENIUL ACOPERIT CONINE 3 SUBDOMENII
DIRECIILE SPECIFICE:
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
3. ILUMINATUL
- ILUMINATUL NATURAL
- ILUMINATUL ARTIFICIAL
- IMPACTUL ILUMINATULUI ASUPRA CONSUMULUI
TOTAL DE ENERGIE
Universitatea Politehnica din Timisoara
DOMENIUL ACOPERIT CONINE 3 SUBDOMENII
DIRECIILE SPECIFICE:
FIZICA CONSTRUC FIZICA CONSTRUC IILOR IILOR
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
FIZICA CONSTRUCIILOR OPEREAZ CU DIVERSE CRITERII:
- CERINE REFERITOARE LA CONFORTUL UMAN I CERINE LEGATE DE SNTATE
- CERINE REFERITOARE LA PROBLEME FUNCIONALE I ARHITECTURALE
- CERINE REFERITOARE LA MATERIALE, POLUARE, ECONOMIE DE ENERGIE
- DEZVOLTAREA DURABIL A CONSTRUCIILOR
Universitatea Politehnica din Timisoara
FIZICA CONSTRUC
FIZICA CONSTRUC

IILOR
IILOR
-
-
CRITERII
CRITERII
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
EVOLU
EVOLU

IA EFICIEN
IA EFICIEN

EI
EI
ENERGETICE
ENERGETICE

N CONSTRUC
N CONSTRUC

II
II
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORME, STANDARDE, CODURI NORME, STANDARDE, CODURI
1973 1973 - - 1983 1983
1983 1983 - - 1997 1997
1997 1997 - - 2009 2009
PERIOADE PERIOADE
PRINCIPALE PRINCIPALE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORME, STANDARDE, CODURI NORME, STANDARDE, CODURI
STAS 6472 2 73 Building Physics. HYGROTHERMICS. External climatic parameters.
STAS 6472 3 83 Building Physics. THERMOTECHNICS. Thermotechnic calculus of
building structural elements.
STAS 6472 4 81 Building Physics. HEAT ENGINEERINGS. Response of structural
elements to water vapour diffusion. Calculation specifications.
STAS 6472 5 73 Building Physics. HYGROTERMICS. Designing and implementation
principles for ventilated roofing.
STAS 6472 6 74 Building Physics. Thermotechnic design of structural elements with
thermal bridges.
STAS 6472 7 75 Building Physics. Thermotechnics. Calculus of air permeability of
building materials and components.
STAS 6472 10 81 Building Physics. Thermotechnics. Thermal transfer at floor contact.
Classification and determination method.
1973 1973 - - 1983 1983
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORME, STANDARDE, CODURI NORME, STANDARDE, CODURI
STAS 6472 2 83 Building Physics. HYGROTHERMICS. External climatic parameters.
STAS 6472 3 89 Building Physics. THERMOTECHNICS. Thermotechnics calculus of
building structural elements.
STAS 6472 4 89 Building Physics. HEAT ENGINEERINGS. Response of structural
elements to water vapour diffusion. Calculation specifications.
STAS 6472 6 88 Building Physics. Thermotechnic design of structural elements with
thermal bridges.
STAS 6472 7 85 Building Physics. Thermotechnics. Calculus of air permeability of
building materials and components.
STAS 6472 10 85 Building Physics. Thermotechnics. Thermal transfer at floor contact.
Classification and determination method.
STAS 6472 11 85 Building Physics. Thermotechnics. Determination of air permeability of
building materials and components.
1983 1983 - - 1997 1997
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
DETERMINAREA REZISTEN
DETERMINAREA REZISTEN

EI LA TRANSFER
EI LA TRANSFER
TERMIC P
TERMIC P
N
N

N 198
N 198
9
9
R
o
Rezistena total la transfer termic [m
2
K/W];
R
i
Rezistena la transfer termic pe suprafaa interioar [m
2
K/W];
R
e
Rezistena la transfer termic pe suprafaa exterioar [m
2
K/W];
- Rezistena la transfer termic a elementului [m
2
K/W]
e i
R R R R + + =
0

R
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
nec 0
0
oc
R
m
R
R > =
R
o
Rezistena total la transfer termic [m
2
K/W];
R
oc
Rezistena la transfer termic innd cont de masivitatea elementuli [m
2
K/W];
m masivitatea elementului funcie de ineria materialului;
R
o nec
Rezistena minim la transfer termic [m
2
K/W].
DETERMINAREA REZISTEN
DETERMINAREA REZISTEN

EI LA
EI LA
TRANSFER TERMIC P
TRANSFER TERMIC P
N
N

N 198
N 198
9
9
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
VERIFICATION OF CONDENSE
VERIFICATION OF CONDENSE
APPEARANCE ON THE INTERIOR SURFACE
APPEARANCE ON THE INTERIOR SURFACE
T
si
Temperatura suprafeei interioare [C];
t
r
Temperatura punctului de rou [C].
r si
T t >
VERIFICAREA APARI VERIFICAREA APARI IEI CONDENSULUI IEI CONDENSULUI N INTERIORUL ELEMENTULUI N INTERIORUL ELEMENTULUI
m
w
Masa de ap condensat n perioada rece a anului;
m
v
Masa de ap care se evapor n perioada cald a anului.
0 s
v w
m m
Wadmis W
ef
A s A
AW
ef
Procentul de mas de ap condensat n perioada rece a anului;
AW
admis
Procentul de mas de ap acceptat.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

A LA TRANSFER TERMIC
A LA TRANSFER TERMIC
PERIOADA STAS R
min
[m
2
K/W] R [m
2
K/W]
PERETI TERASA PLANSEE
PESTE
SUBSOL
PERETI TERASA PLANSEE
PESTE
SUBSOL
1950 1961 - - - - - - -
1962 1968 STAS 6472 61 0.76 0.96 0.82 - - -
1969 1973 STAS 6472 68 0.80 1.02 0.87 0.60 - -
1974 1975 STAS 6472/3 73 0.80 1.02 0.87 0.60 - -
1976 1984 STAS 6472/3 75 0.80 1.02 0.87 0.60 - -
1985 1987 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
NP 15 - 84 1.20 1.55 1.08 1.20 1.55 1.08
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

A LA TRANSFER TERMIC
A LA TRANSFER TERMIC
PERIOADA STAS-NORMATIV R
min
[m
2
K/W] R [m2K/W]
PERETE
EXTERIOR
TERASA PLANSEU
PESTE
SUBSOL
PERETE
EXTERIOR
TERASA PLANSEU
PESTE
SUBSOL
1988 1989 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
NP 15 87 1.20 1.55 1.08 1.20 1.55 1.08
1990 1997 STAS 6472/3 89 1.00 1.24 0.67 1.00 1.24 0.67
1998 2000 C107/3 1997 - - - 1.09 1.46 1.25
C107/1 1997 - - - 1.40 3.00 1.65
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

A LA TRANSFER TERMIC
A LA TRANSFER TERMIC
PERIOADA STAS - NORMATIV R
min
[m
2
K/W] R [m2K/W]
PERETE TERASA PLANSEU
PESTE
SUBSOL
PERETE TERASA PLANSEU
PESTE
SUBSOL
1988 1989 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
NP 15 87 1.20 1.55 1.08 1.20 1.55 1.08
1990 1997 STAS 6472/3 89 1.00 1.24 0.67 1.00 1.24 0.67
1998 2000 C107/3 1997 - - - 1.09 1.46 1.25
C107/1 1997 - - - 1.40 3.00 1.65
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
TIPURI DE ELEMENTE DE
TIPURI DE ELEMENTE DE

NCHIDERE
NCHIDERE
UTILIZATE P
UTILIZATE P
N
N

N
N
1984
1984
25 cm 37 cm
5
30 cm 5
27 cm
12 9
5 5
6
27 cm
8 12
5 5
30 cm 5
30 cm
12 12
5 5
B C D
E F G
A
Autoclaved aerated
concrete
brick
masonry
brick with vertical
hollows
reinforced
concrete
AAC
reinforced
concrete
mineral
wool
AAC
reinforced
concrete
reinforced
concrete
AAC
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

E LA TRANSFER TERMIC
E LA TRANSFER TERMIC
PENTRU PERE
PENTRU PERE

I P
I P
N
N

N 1984
N 1984
TIPUL ELEMNTULUI EXTERIOR TIPUL ELEMNTULUI EXTERIOR A A B B C C D D E E F F G G
Rezisten Rezisten a la transfer termic a la transfer termic
R R
0,ef 0,ef
[m [m
2 2
K/W] K/W]
0.68 0.68 0.57 0.57 0.54 0.54 0.57 0.57 0.97 0.97 0.93 0.93 0.67 0.67
R R
0,ef 0,ef
/ R / R
0,nec 0,nec
0.57 0.57 0.48 0.48 0.45 0.45 0.48 0.48 0.81 0.81 0.77 0.77 0.56 0.56
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
35 cm
45 cm
15 30 2
30 cm
7 12 8
5 5
a b c
d
45 cm 7
27 cm
8 12
e f
35 cm
20 15
AAC
masonry
AAC
brick
masonry
reinforced
concrete
mineral
wool
AAC
AAC
masonry
reinforced
concrete
mineral
wool
AAC
reinforced
concrete
TIPURI DE ELEMENTE DE
TIPURI DE ELEMENTE DE

NCHIDERE
NCHIDERE
UTILIZATE
UTILIZATE
DUP
DUP


1984
1984
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

E LA TRANSFER TERMIC
E LA TRANSFER TERMIC
PENTRU PERE
PENTRU PERE

I DUP
I DUP


1984
1984
TIP ELEMENT ETERIOR TIP ELEMENT ETERIOR A A B B C C D D E E F F
Rezisten Rezisten a la transfer termic a la transfer termic
R R
0,ef 0,ef
[m [m
2 2
K/W] K/W]
1.84 1.84 1.38 1.38 1.63 1.63 2.43 2.43 1.56 1.56 1.61 1.61
R R
0,ef 0,ef
/ R / R
0,nec 0,nec
1.53 1.53 1.15 1.15 1.35 1.35 2.02 2.02 1.30 1.30 1.34 1.34
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
ELEMENT
R
m
[m
2
K/W]
PN LA 01. 01. 1998 DUP 01. 01. 1998 /
RECOMANDAT
PEREI EXTERIORI (excepie ferestre i ui) 1.20 1.40 / 2.00
FERESTRE I UI EXTERIOARE 0.40 0.50
TERASE 2.00 3.00
PLANSEE PESTE SUBSOLURI SAU SPATII
NEINCLZITE
1.10 1.65
PLCI PE SOL 3.00 4.50
STUDIU COPARATIV PRIVIND REZISTEN
STUDIU COPARATIV PRIVIND REZISTEN

A
A
LA TRANSFER TERMIC
LA TRANSFER TERMIC
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
ENERGETIC CONSUMPTION FOR ONE FLAT FROM
RESIDENCIAL BUILDING (1970 - 1985)
Lighting, 14%
Gas, 10%
Hot water,
21%
Heating, 55%
Lighting
Gas
Hot water
Heating
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CL
CL

DIRI DE LOCUIT DIN


DIRI DE LOCUIT DIN
TIMISOARA
TIMISOARA
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CL
CL

DIRI DE LOCUIT DIN


DIRI DE LOCUIT DIN
TIMISOARA
TIMISOARA
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORMATIVE SI STANDARDE
NORMATIVE SI STANDARDE
1997 1997 - - 2006 2006
Nr.
Crt.
INDICATIV DOCUMENTUL
1. C107/1 - 1997 Normativ privind calculul coeficientilor globali de izolare termica la cladirile de locuit
2. C107/2 - 1997 Normativ pentru calculul coeficientului global de izolare termic la cldiri cu alt
destinaie dect cele de locuit
3. C107/3 - 1997 Normativ privind calculul termotehnica al elementelor de constructie ale cladirilor
4. C107/4 - 1997 Ghid pentru calculul performantelor termotehnice ale cladirilor de clocuit
5. C107/5 - 1997 Normativ privind calculul termotehnic al elementelor de constructie in contact cu solul
6. NP 048- 2000 Normativ pentru expertizarea termica si energetica acladirilor existente si a instalatiilor
de incalzire si preparare a apei calde de consum aferente acestora
7. NP 047- 2000 Normativ pentru realizarea auditului energetic al caldirilor existentesi al instalatiilor de
incalzire si preparare a apei calde de consum aferente acestora
8. NP 049- 2000 Normativ pentru elaborarea si acordarea certificatului energetic al cladirilor existente
9. GP 058 - 2000 Ghid privind optimizarea nivelului de protectie termica la cladirile de locuit
10. GP 015 - 2000 Ghid pentru expertiazarea si adoptarea solutiilor de imbunatatire a protectiei termice si
acustice la cladiri existente unifamniliale sau cu numar redus de apartamente
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORMATIVE SI STANDARDE NORMATIVE SI STANDARDE 1997 1997 - - 2006 2006
11. SR ISO 7730 Ambiante termice moderate. Determinarea indicilor PMV si PPD si
specificarea conditiilor de confort termic
12. GT 037- 2002 Ghid pentru elaborarea si acordarea certificatului energetic al cladirilor
existente
13. GT 036- 2002 Ghid pentru efectuarea expertizei termice si energetice a cladirilor de locuit
existente si a instalatiilor de incalzire a apei calde de consum aferente
acestora,
14. GT 040- 2002 Ghid de evaluare a gradului de izolare termica al elementelor de constructie
la cladiri existente in vederea reabilitarii termice
15. MP 022- 2002 Metodologie pentru evaluarea performantelor termotehnice ale materialelor
si produselor pentru constructii
16. GT 043- 2002 Ghid pentru imbunatatirea calitatilor termoizolatoare ale ferestrelor la
cladirile civile existente
17. NP 064- 2002 Normativ pentru proiectarea mansardelor la cladiri de locuit,
18. GT 039- 2002 Ghid de evaluare a gradului de confort higrotermic din unitatile functionale
ale clafirilor existente
19. GT 038- 2002 Ghid pentru determinarea performantelor energetice ale instalatiilor de
incalzire si de apa calda de consum din cladirile social-culturale existente, in
vederea reabilitarii si modernizarii acestora
20. SC 007- 2002 Solutii cadru pentru reabilitarea termo-higro-energetica a anvelopei cladirilor
de locuit existente
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORMATIVE SI STANDARDE
NORMATIVE SI STANDARDE
1997 1997 - - 2006 2006
21. NP 060- 2002 Normativ privind stabilirea performantelor termo-higro-energetice ale
anvelopei cladirilor de locuit existente in vederea reabilitarii termice
22. SC 007 - 2002 Solutii cadru pentru reabilitarea termo-higro-energetica a anvelopei cladirilor
de locuit existente
23. C107/0 - 2002 Normativ pentru proiectarea si executia lucrarilor de izolatii termice la cladiri
24. C107/7 - 2002 Normativ pentru proiectarea stabilitatii termice a elementelor de inchidere ale
cladirilor,
25. C107/6 - 2002 Normativ general privind calculul transferului de masa (umiditate) prin
elementele de constructie
26. C107/7 - 2002 Normativ pentru proiectarea la stabilitate termica a elementelor de inchidere
ale cladirilor
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORMATIVE NORMATIVE I STANDARDE I STANDARDE - -
REVI REVIZUITE ZUITE
EN ISO 13789 Thermal performance of buildings
Transmission heat loss coefficient Calculation method.
EN ISO 7345 Thermal insulation Physical quantities and
definitions.
C 107 .... /2005 Normativ pentru calculul coeficientului global de
izolare termic pentru cldiri de locuit
PRESCRIP PRESCRIP II EUROPENE II EUROPENE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
NORMATIVE
NORMATIVE

I STANDARDE
I STANDARDE
ROMANE
ROMANE

TI
TI
1997 1997 - - 2006 2006
ROMANIAN CODES
24
7
10
0
5
10
15
20
25
30
1973 - 1983 1983 - 1997 1997 - 2006
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
BLOC DE LOCUIT CU SUBSOL BLOC DE LOCUIT CU SUBSOL I 4 ETAJE I 4 ETAJE 20 20 apartamente apartamente
Tip perete exteror Tip perete exteror Panou prefabricat Panou prefabricat 27 cm 27 cm
- - Beton armat Beton armat
- - BCA BCA
- - Beton armat Beton armat
Ferestre exterioare Ferestre exterioare cuplate cu rame din lemn cuplate cu rame din lemn
U U i exterioare i exterioare cu rame metalice cu rame metalice i geam simplu i geam simplu
5 12 9
5 5
reinforced
concrete
AAC
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
14 3.46
3.46
1.30
1.30
21.92
3.60
9
0
9
02
.1
0
9
0
2
.1
0
9
0
4
.6
6
1
.1
5
1
.1
5
3
.4
6
4
.6
6
Hol
s=4.73 mp
2.10
80
1.28
1.03
3.00
Baia
s=4.12 mp
3 2 1
2.86
2.10
85
3.06
Logia
s=3.28 mp
2
7
90
13
5
1
.2
0
27
2.40
3.60
1.30 75
5
1.20 1.20
2
7
h =90
p
3.46
8
0
1
0
h =90
p
2
.1
0
14
Dormitor
s=9.90 mp
14
Camera de zi
s=16.07 mp
6 5 4
1
80
1.50
1.20
3.00
Bucataria
s=4.57 mp 2
.7
5
Bucataria
s=4.57 mp
75
2.40
1.20 43 60
60 1.20
2
7
h =90
p
h =90
p
74 1.60
2.10
38
2.26 1.50
5
7
5
14
1.26
7
6
2.10
80
1.50
2.10
14
2
.1
0
2
.1
0
2.10
2
.7
5
2.40 1.03 60 43
1.20 60
h =90
p
h =90
2
7
p
1.20
h =90
p
2
7
1.28 7
5
14
5
Baia
s=4.12 mp
1.26 80
7
6
2.10
Camera de zi
s=16.07 mp
2.10
80
2
.1
0
1
0
1
0
9
0
1.28
1.03
Baia
s=4.12 mp
2.40 75 1.30 90 85
2.73
2.10
Logia
s=3.28 mp
3
.4
6
1
4
1
.2
0
2
7
27
4
.6
6
Dormitor
s=9.90 mp
1
4
Camera de zi
s=16.07 mp
3.46
1
0
8
0
h =90
p
2
.1
0
1.20
27
2
7
h =90
p
1.20
14
1.03 2.40 60 1.20 43 74 74 1.60 43 60 1.20
80
1.50
Bucataria
s=4.57 mp
2
.7
5
1
0
2
4
2
0
9
0
2.10
80 1.26
1
.1
5
1
4
Hol
s=4.73 mp
Hol
s=3.47 mp
7
6
2.10
9
0
2
.1
0
2
0
2
4
1
0
2
.1
0
2.26
Bucataria
s=4.57 mp
2
7
1.50
p
h =90
5 5
7
60
h =90
p
14
1.20
80 25
2.10
h =90
p
60
14
4
.6
6
2
.7
5
2.10
1.26 80
9
0
1
.1
5
Hol
s=3.47 mp
1
4
1
0
1
0
2
.1
0
7
6
1
4
Camera de zi
s=16.07 mp
Baia
s=4.12 mp
h =90
p
1.28
2
7
h =90
p
5
7
1.20
14
5
60
h =90
2
7
p
1.20
1
3
.4
6
8 7
2
7
1
.2
0
90
3.07
85 75
1.20
5
2.10
Logia
s=3.28 mp
5
13
2.86
8
0
2
.1
0
1
0
h =90
p
Dormitor
s=9.90 mp
27
85 75 90
3
.4
6
1
4
Dormitor
s=9.90 mp
2
7
1
.2
0
2.73
8
0
2
.1
0
1
0
h =90
p
27
1.20
Logia
s=3.28 mp
2.10
27
2
4
.8
7
5
1
3
5
1
3
4
.8
7
1
0
.0
0
C
B
A
2
SECTI
SECTI
UNE
UNE
ORIZONTAL
ORIZONTAL
A
A
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
Calculul coeficientului global de izolare termic Calculul coeficientului global de izolare termic
CONDIIILE IMPUSE DE C 107/3-2005
R`
m
R`
min
and
GGN
are not satisfied!
t
'
m
R
A
t
No. Element A R

m
R

min
G GN
[m
2
] [m
2
K/W] [m
2
K/W] - [W/K] [W/m
3
K]
1. Perete exterior 554.37 0.64 1.40 1.00 866.20 0.66 0.57
2. Ferestre exterioare 148.50 0.40 0.50 1.00 371.25
3. Teras 189.54 2.08 3.00 1.00 91.125
4. Placa peste subsol 189.54 2.94 4.5 0.43 27.720
TOTAL 1081.95 1356.30
REABILITAREA C
REABILITAREA C

MINULUI
MINULUI
C 2
C 2
0
0
PREZENTARE GENERAL
- AMPLASAMENT: CAMPUSUL STUDENESC TIMIOARA-ROMANIA
- ANUL CONSTRUIRII: 1978
- REGIM DE NLIME: 7 (SUBSOL, PARTER SI 5 ETAJE)
- DESTINAIE: CAZARE STUDENI PE PERIOADA ANULUI UNIVERSITAR
- SISTEM STRUCTURAL VERTICAL:
FAADE EXTERIOARE: PANOURI MARI PREFABRICATE
INTERIOR: PEREI MONOLII DIN BETON ARMAT (DIAFRAGME)
- SISTEM ORIZONTAL:
PANOURI PREFABRICATE DIN BETON ARMAT
- ACOPERI INITIAL : ACOPERI DE TIP TERAS (PLAT )
- ACOPERI ACTUAL : ARPANT EXECUTAT N ANUL 1995
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
NORD VEST FAAD
SUD EST FAAD
C
C

MINUL STUDEN
MINUL STUDEN

ESC C2
ESC C2
0
0
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC
ESC
C 2
C 2
0
0
SECIUNE ORIZONTAL
A
1 2 3 4
B
HOL
4,67mp
ozaic
C
HOL, WC, DUS 101
S=10,00mp
mozaic
CAMERA 101 B
S=20,90mp
covor PVC
CAMERA 100
S=20,57mp
beton
CAMERA 101 A
S=20,90mp
covor PVC
HOL,WC,DUS100
S=5,25mp
mozaic
+2,88
MAGAZIE
S=2,20mp
mozaic
HOL, WC, DUS 110
S=10,00mp
mozaic
SALA DE LECTURA ETAJ 1
S=62,78mp
mozaic
D
CAMERA 110 B
S=20,90mp
covor PVC
+1,44
CAMERA 110 A
S=20,90mp
covor PVC
4
5 6 7 8 9
HOL, WC, DUS 103
S=10,00mp
mozaic
HOL, WC, DUS 108
S=10,00mp
mozaic
HOL, WC, DUS 102
S=10,00mp
mozaic
CAMERA 102 A
S=20,90mp
covor PVC
CAMERA 102 B
S=20,90mp
covor PVC
CAMERA 103 B
S=20,90mp
covor PVC
HOL, WC, DUS 109
S=10,00mp
mozaic
CAMERA 104 B
S=20,90mp
covor PVC
CAMERA 103 A
S=20,90mp
covor PVC
CULOAR ETAJ I
S=108,18mp
mozaic
CAMERA 109 B
S=20,90mp
covor PVC
CAMERA 109 A
S=20,90mp
covor PVC
CAMERA 108 B
S=20,90mp
covor PVC
5 6 7
CAMERA 108 A
S=20,90mp
covor PVC
CAMERA 107 B
S=20,90mp
covor PVC
8 9
10 11 12 13
CAMERA 106 B
S=20,90mp
covor PVC
CAMERA 105 B
S=20,90mp
covor PVC
HOL, WC, DUS 104
S=10,00mp
mozaic
CAMERA 104 A
S=20,90mp
covor PVC
HOL, WC, DUS 107
S=10,00mp
mozaic
CAMERA 107 A
S=20,90mp
covor PVC
10
HOL+WC+GHENA
S=8,00 mp
mozaic
HOL, WC, DUS 105
S=10,00mp
mozaic
CAMERA 105 A
S=20,90mp
covor PVC
SPALATORIE
(FUMOAR)
S=17,80 mp
mozaic
HOL, WC, DUS 106
S=10,00mp
mozaic
+2,88
MAGAZIE
S=2,20mp
mozaic
CAMERA 106 A
S=20,90mp
covor PVC
+1,44
11 12 12' 13
S=62,78mp
mozaic
SUPRAFAA TOTAL: 6566 m
2
(938 m
2
SUBSOL TEHNIC)
FIECARE ETAJ ARE 10 APARTMENTE CU 2 CAMERE,
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
ALCTUIREA ARHITECTURAL FUNCIONAL A UNUI APARTMENT
APARTMENT
-2 CAMERE
- 1 HOL (2 LAVOARE)
- 1 CAMER DE DU
- 1 WC SERVICIU
.88
3.90
4.05
4.20
1.80
.
8
0
2.10
1.80
.15
2
.
1
0
.
2
3
.
5
5
.15 .88 .90
2.10
.08 .10
.08
ROOM
S=20,90mp
ROOM
S=20,90mp
4.05
4.20
2.40
.15 .15
p=90
1.30
4 5
.
8
0
.15
.
0
8.
5
5
.
2
3
2
.
1
0
.10 .07 2.10 .90
2.10
1.80 .07
.15
p=90
2.40
1.30
6
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC
ESC
C 2
C 2
0
0
VEDERE INTERIOAR PERETE NORD VEST
MUCEGAI PE PERETELE INTERIOR
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C C MINUL STUDEN MINUL STUDEN ESC ESC C 2 C 20 0 STAREA INI STAREA INI IAL IAL
Degradarea finisajelor i instalaiilor
Starea tmplriei exterioare
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C C MINUL STUDEN MINUL STUDEN ESC ESC C 2 C 20 0 STAREA INI STAREA INI IAL IAL
Degradarea linoleumului n camere Panou electric
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C C MINUL STUDEN MINUL STUDEN ESC ESC C 2 C 20 0 STAREA INI STAREA INI IAL IAL
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
- EXPERTIZA STRUCTURAL
- NU AU FOST SEMNALATE DEFECTE ALE STRUCTURII N TIMPUL EXPLOATRII
- IZOLAREA TERMIC
- Rezisten mic la transfer termic ~ 0.8 [m
2
K/W]
- Fenomenul de condens a fost semnalat fe suprafaa interioar cu precdere la pereii
de pe direcia NV
- SISTEMUL DE NCLZIRE
- nclzirea a fost asigurat de sistemul centralizat de la nivelul oraului
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
- INTERVENII STRUCTURALE
- DIN PUNCT DE VEDERE STRUCTURAL, CLDIREA ARE CAPACITATEA DE
PRELUARE ATT A SARCINILOR GRAVITAIONALE CT I ORIZONTALE (SEISM).
- PROPUNEREA DE REALIZARE A UNEI CENTRALE TERMICE PROPRII A CONDUS LA
NECESITATEA UNOR CONSOLIDRI LA NIVELUL PLANEULUI PESTE SUBSOL I
PARTER, DATORIT CRETERII NCRCRII ADUSE DE INSTALAII I
ECHIPAMENTELE CENTRALEI TERMICE.
- PLANEELE PE CARE SE VA REALIZA CENTRALA TERMIC AU FOST EXECUTATE
CA PLANEE PREFABRICATE DIN BETON ARMAT DE 9 CM GROSIME, DIMENSIONATE
LA O NCRCARE UTIL DE 1.50 KN/m
2
.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
- INTERVENII STRUCTURALE
91.5 25 129 25 129 25 129 25 66.5
1
5
1
5
1
2
4
0
5
3
0
B
e
a
m

G
e

1

2
5
x
2
5
B
e
a
m

G
e

1

2
5
x
2
5
B
e
a
m

G
e

1

2
5
x
2
5
B
e
a
m

G
e

1

2
5
x
2
5
1
1
1
20
3
2
4
30 645 15
1
5
1
5
1
5
1
5
1
5
1
5
1
5
1
- NOUL PLANEU
PROPUS ARE GRINZI
DE BETON ARMAT
PENTRU PRELUAREA
NCRCRILOR
VERTICALE
CONCENTRATE
ADUSE DE
ECHIPAMENTELE DIN
CENTRALA TERMIC
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
- SOLUIA STRUCTURAL ADOPTAT
1
5
1
2
1
0
5
Section 1-1
2
5
2
5
FIRST STOREY
GROUND LEVEL
30 645 15
4
5
5
5
5
5
5
+3.05
- PENTRU A NU SUPRANCRCA PLANEUL EXISTENT, NTRE GRINZILE PLANEULUI
PROPUS I CELUI EXISTENT A FOST DISPUS UN STRAT DE POLISTIREN.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
- ASPECTE DIN TIMPUL EXECUIEI
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
- ASPECTE DIN TIMPUL EXECUIEI
C
C

MINUL STUDEN
MINUL STUDEN

ESC C 2
ESC C 2
0
0
-
-
REABILITA
REABILITA
RE
RE
1.EVALUAREA PERFORMANELOR ENERGETICE A CLDIRII
Precast Panel Type 1 Precast Panel Type 1
(The side panel) (The side panel)
- - Reinforced concrete 20 cm, Reinforced concrete 20 cm,
- - Autoclaved aerated concrete 12.5 cm, Autoclaved aerated concrete 12.5 cm,
- - Reinforced concrete 6 cm, Reinforced concrete 6 cm,
- - Mortar coating 1.5 cm Mortar coating 1.5 cm
Precast Panel Type 2 Precast Panel Type 2
(Between the (Between the
windows) windows)
- - Renforced concrete 20 cm, Renforced concrete 20 cm,
- - Autoclaved aerated concrete 12.5 cm, Autoclaved aerated concrete 12.5 cm,
- - Mortar 0.5 cm Mortar 0.5 cm
Precast Panel Type 3 Precast Panel Type 3
( (The bottom panel The bottom panel
under the window under the window ) )
- - Reinforced Reinforced c concrete 10 cm, oncrete 10 cm,
- - Autoclaved aerated concrete 12.5 cm, Autoclaved aerated concrete 12.5 cm,
- - Reinforced concrete 7.5 cm Reinforced concrete 7.5 cm
Precast Panel Type 4 Precast Panel Type 4
( (The front walls The front walls) )
- - Reinforced concrete 15 cm, Reinforced concrete 15 cm,
- - Autoclaved aerated concrete 12.5 cm, Autoclaved aerated concrete 12.5 cm,
- - Face bricks 7.5 cm Face bricks 7.5 cm
1. TIPURI DE ELEMENTE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Double Double- -winged coupled windows winged coupled windows
Single Single- -wing windows wing windows
Metallic single Metallic single- -wing doors wing doors
The flat roof over the fifth The flat roof over the fifth
storey storey
- - Reinforced concrete 9 Reinforced concrete 9 - - 10 cm, 10 cm,
- - Vapour barrier made of bituminous membrane of 0.02cm, Vapour barrier made of bituminous membrane of 0.02cm,
- - Autoclaved aerated concrete 12.5 cm Autoclaved aerated concrete 12.5 cm
- - Cement flooring 10 cm Cement flooring 10 cm
- - Waterproof membrane with 5 layers (1cm) Waterproof membrane with 5 layers (1cm)
The floor over the basement The floor over the basement - - Linoleum 0.5 cm, Linoleum 0.5 cm,
- - Mortar 10 cm, Mortar 10 cm,
- - Reinforced concrete 9 Reinforced concrete 9 - - 10 cm. 10 cm.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
1.EVALUAREA PERFORMANELOR ENERGETICE A CLDIRII
1. TIPURI DE ELEMENTE
REZISTENA LA TRANSFER TERMIC, REZISTENA LA TRANSFER TERMIC
MINIM, REZISTENA LA TRANSFER TERMIC MEDIE PE CLDIRE.
Type R
[m
2
K/W]
R
nec
[m
2
K/W]
R/R
nec
R
[m
2
K/W]
Precast Panel Type 1 0.82 1.4 0.58
0.61
Precast Panel Type 2 0.78 1.4 0.55
Precast Panel Type 3 0.77 1.4 0.55
Precast Panel Type 4 0.9 1.4 0.64
Double Coupled Window 0.39 0.5 0.78
Simple Window 0.17 0.5 0.34
Metallic Door 0.17 0.5 0.34
Roof floor 0.87 3.00 0.29
Floor under basement 0.39 1.65 0.23
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
1. EVALUAREA PERFORMANELOR ENERGETICE A CLDIRII
C
A B C D E F G H I J
A B C D E F G H I J
G
D
A B C D E F G H I J
NCLZIRE 124.9 [KWh/m
2
an]
80 121 166 217 277 347 433 544 700
AP CALD150 [KWh/m
2
an]
25 43 63 86 112 143 182 231 300
TOTAL UTILITI 274.9 [KWh/m
2
an]
105 164 229 303 389 490 615 775 1000
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
C C MINUL STUDEN MINUL STUDEN ESC C 2 ESC C 20 0 REABILITA REABILITARE RE
SOLU SOLU II ADOPTATE PENTRU REABILITAREA TERMIC II ADOPTATE PENTRU REABILITAREA TERMIC
PEREI EXTERIORI
- a fost propus realizarea unui sistem de termoizolare compus dintr-un strat de polistiren
aplicat la exterior (5 cm polistiren), peste care se va realiza un strat de finisaj pe suport de
fibr de sticl. Cldirea se va zugrvi n culori pastelate.
TMPLRIA EXISTENT
- a fost complet nlocuit cu ferestre cu rame de PVC i geam termoizolant.
PLANEUL PESTE SUBSOL
- a fost termoizolat prin aplicarea unui strat de polistiren de 5 cm grosime
PLANEUL PESTE ULTIMUL NIVEL
- a fost termoizolat prin aplicarea unui strat de polistiren de 10 cm grosime protejat de un
strat de ap din mortar de ciment cu grosimea minim de 2 cm.
CENTRALA TERMIC
- a fost propus o central termic local pe gaz,
- schimbarea radiatoarelor i conductelor de distribuie
- Conductele de distribuie propuse se vor executa din polipropilen de nalt densitate,
preizolate dispuse la subsolul cldirii.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
REZISTENA LA TRANSFER TERMIC A ELEMENTELOR CLDIRII
REABILITATE
Type R
[m
2
K/W]
R
nec
[m
2
K/W]
R/R
nec
R
[m
2
K/W]
Precast Panel Type 1_R 2.17 1.4 1.55
1.37
Precast Panel Type 2_R 2.13 1.4 1.52
Precast Panel Type 3_R 2.11 1.4 1.50
Precast Panel Type 4_R 0.9 0.5 0.64
Double Window_C 0.5 0.5 1
Thermoinsulated Door_C 0.5 0.5 1
Roof floor_R 3.49 3.00 1.16
Floor under basement_R 1.65 1.65 1
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
1.CERTIFICAREA ENERGETIC A CLDIRII REABILITATE
A
A B C D E F G H I J
A B C D E F G H I J
C
B
A B C D E F G H I J
NCLZIRE 62 [KWh/m
2
an]
80 121 166 217 277 347 433 544 700
AP CALD 54 [KWh/m
2
an]
25 43 63 86 112 143 182 231 300
TOTAL ENERGIE 116 [KWh/m
2
an]
105 164 229 303 389 490 615 775 1000
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Reabilitarea termic a
peretelui exterior
Tmplrie PVC
cu geam
termoizolant
Strat de polistiren suplimentar
Faada SV
REABILITAREA TERMIC A CMINULUI C20
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
REABILITAREA TERMIC
FAADA SE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
REABILITAREA INTERIOAR
VEDERE DIN CAMERA CURENT I DU
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
STUDIU ECONOMIC AL INVESTIIEI
Heating, 5.06
Ventilation, 1.27
Sanitary, 10.60
Sewerage sistem, 0.49
Heating station, 4.07
Hydrophore, 0.96
Strengthening, 0.38 Gas, 0.05
Electric, 19.81
Thermal reabilitation, 10.85
Interior arrangement, 46.47
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
STUDIU ECONOMIC AL INVESTIIEI
Heati ng stati on, 4.07
Hydr ophor e, 0.96
Ther mal r eabi l i tati on, 10.85
Bui l di ng r eabi l i tati on, 46.85
Instal l ati ons, 37.27
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
STUDIU COMPARATIV PRIVIND ENERGIA CONSUMAT
91.1
101.5
134.1
91
76.5
89.7
82.4
75.4
0
20
40
60
80
100
120
140
160
decembre january february march
Months
H
e
a
t
i
n
g

c
o
n
s
u
m
p
t
i
o
n

[
G
C
a
l
]
2004/2005
2006/2007
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
CONCLUZII
Dup reabilitare reducerea energiei totale consumate este de 50%. Reducerea este datorat
dublrii rezistenei la transfer termic pe cldire i reducerii pierderilor de pe coloanele de
distribuie. Nu este de neglijat faptul c prin poziionarea n cldire a centralei termice pierderile de
cldur de la punctul de furnizare la consumator au fost eliminate.
Reducerea important a consumului de energie pentru prepararea apei calde de consum este
datorat eficienei centralei termice i randamentului crescut al acesteia.
Lund n considerare costul total privind reabilitarea termic care este de aproximativ 110.000
Euro i economia de 2100 Euro/lun pentu nclzire i ap cald de consum, valoarea investiiei
pentru reabilitarea termic se amortizeaz n aproximativ 6 ani.
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
CENTRUL COMERCIAL IULIUS MALL Timisoara
- 72. 000 m
2
- 3 ETAJE
- > 220 MAGAZINE
- PISCIN
- MULTIPLEX CINEMA
- KIDS LAND
- FOOD COURT
CONSTRUIT IN 16 LUNI
- ~ 3.000 t ARMTURI I OEL STRUCTURAL
- ~ 80.000 m
3
BETON
- 13.847 m
2
VAT MINERAL 5 cm grosime + PANOURI SANDWICH 6 cm
- 18.500 m
2
POLISTIREN 10 cm grosime
- 4.200 m
2
FERESTRE DUBLE I UI TERMOIZOLATE
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CORP C
CORP D
CORP E
CORP N
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CENTRUL COMERCIAL IULIUS MALL Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CENTRUL COMERCIAL IULIUS MALL Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CENTRUL COMERCIAL IULIUS MALL Timisoara
IZOLAII
TERMICE I
HIDROFUGE
SISTEMUL DE
IZOLARE
TERMIC LA
FAAD
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CENTRUL COMERCIAL IULIUS MALL Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
Universitatea Politehnica din Timisoara
CENTRUL COMERCIAL IULIUS MALL Timisoara
Fizica constructiilor Fizica constructiilor - - Constructii II Constructii II
Curs nr. 1
FIZICA CONSTRUCIILOR OPEREAZ CU DIVERSE CRITERII:
- CERINE REFERITOARE LA CONFORTUL UMAN I CERINE LEGATE DE SNTATE
- CERINE REFERITOARE LA PROBLEME FUNCIONALE I ARHITECTURALE
- CERINE REFERITOARE LA MATERIALE, POLUARE, ECONOMIE DE ENERGIE
- DEZVOLTAREA DURABIL A CONSTRUCIILOR
Universitatea Politehnica din Timisoara
FIZICA CONSTRUC
FIZICA CONSTRUC

IILOR
IILOR
-
-
CRITERII
CRITERII
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
DETERMINAREA REZISTEN
DETERMINAREA REZISTEN

EI
EI
LA TRANSFER TERMIC
LA TRANSFER TERMIC
R Rezistena total la transfer termic [m
2
K/W];
R
si
Rezistena la transfer termic pe suprafaa interioar [m
2
K/W];
R
se
Rezistena la transfer termic pe suprafaa exterioar [m
2
K/W];
- Rezistena la transfer termic a elementului [m
2
K/W]

+ + + =
se a s si
R R R R R
s
R
- Rezistena la transfer termic a straturilor de aer [m2K/W] a
R
Coeficientul de transfer termic unidirecional se determin cu relaia:
R
U
1
= [W/(m
2
K)]
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

A
A
TERMIC
TERMIC


SPECIFIC
SPECIFIC


CORECTAT
CORECTAT

A A
l
R R
U

+

+ = =
_
1
'
1
'
Rezistena termic specific corectat se determin la elementele de construcie cu alctuire
neomogen.
Aceasta ine seama de influena punilor termice asupra valorii rezistenei termice specifice
determinate pe baza unui calcul unidirecional n cmp curent, respectiv n zona cu alctuirea
predominant.
Rezistena termic specific corectat R i respectiv coeficientul de transfer termic corectat
U' se calculeaz cu relaia general:
n care :
- R este rezistena termic specific unidirecional aferent ariei A;
- l este lungimea punilor liniare de acelai fel, din cadrul suprafeei A.
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
REZISTEN
REZISTEN

A
A
TERMIC
TERMIC


SPECIFIC
SPECIFIC


CORECTAT
CORECTAT

R r R = '
( )
A
l R
r
] [
1
1

+
+
=
_
n care r reprezint coeficientul de reducere a rezistenei termice unidirecionale :
[W/(m
2
K)]
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
DIMENSIONAREA TERMIC
DIMENSIONAREA TERMIC


A
A
ELEMENTELOR DE
ELEMENTELOR DE

NCHIDERE
NCHIDERE
Rezistena termic necesar din considerente igienico-sanitare pentru elemente care separ
spaiul interior nclzit de mediul exterior, se calculeaz cu relaia :
max
'
i i
e i
nec
T
T T
R
A

=
o
n care :
-T
i max
diferena maxim de temperatur, admis ntre temperatura interioar i temperatura medie a
suprafeei interioare T
i max
= T
i
- T
sim
, la elemente care separ spaiul interior nclzit de mediul
exterior.
Valorile Ti max sunt prezentate n funcie de destinaia cldirii i de tipul elementului de
construcie;
T
e
-temperatura exterioar convenional de calcul. Valoarea T
e
se introduce cu semnul algebric
fiind considerat funcie de zonarea teritoriului Romniei;
- T
i
- temperatura interioar convenional de calcul funcie de destinaia ncperilor.
[m
2
K/W]
Condiii igienico - sanitare
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
Grupa
cldirii
Destinaia cldirii
i
(%)
AT
i max
[K]
Perei Tavane Pardoseli
I
-Cldiri de locuit, cmine,
internate
-Spitale, policlinici .a.
-Cree, grdinie
-coli, licee .a.
60 4,0 3,0 2,0
DIMENSIONAREA TERMIC
DIMENSIONAREA TERMIC


A
A
ELEMENTELOR DE
ELEMENTELOR DE

NCHIDERE
NCHIDERE
Condiii igienico - sanitare
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
DIMENSIONAREA TERMIC
DIMENSIONAREA TERMIC


A
A
ELEMENTELOR DE
ELEMENTELOR DE

NCHIDERE
NCHIDERE
Condiia de economie de energie
Nr.
crt.
Elementul de construcie R

min
[m
2
K/W]
CLDIRI PROIECTATE
pn la 1.01.1998 dup 1.01.1998
1. Perei exteriori (exclusiv suprafeele vitrate, inclusiv
pereii adiaceni rosturilor deschise)
1,20 1,40
2. Tmplrie exterioar 0,40 0,50
3. Planee peste ultimul nivel, sub terase sau poduri 2,00 3,00
4. Planee peste subsoluri nenclzite i pivnie 1,10 1,65
5. Perei adiaceni rosturilor nchise 0,90 1,10
6. Planee care delimiteaz cldirea la partea inferioar,
de exterior (la bowindouri, ganguri de trecere)
3,00 4,50
7. Plci pe sol (peste CTS) 3,00 4,50
8. Plci la partea inferioar a demisolurilor sau a
subsolurilor nclzite (sub CTS)
4,20 4,80
9. Perei exteriori, sub CTS, la demisolurile sau la
subsolurile nclzite
2,00 2,40
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
Curs nr. 1
Universitatea Politehnica din Timisoara
DIMENSIONAREA TERMIC
DIMENSIONAREA TERMIC


A
A
ELEMENTELOR DE
ELEMENTELOR DE

NCHIDERE
NCHIDERE
Condiia de economie de energie
Condiii igienico - sanitare
'
min
'
R R >
' '
nec
R R >
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
CONDENSUL IN CONSTRUCTII CONDENSUL IN CONSTRUCTII
Curs 1
Universitatea Politehnica din Timisoara, Romania
VERIFICAREA APARI VERIFICAREA APARI IEI CONDENSULUI PE SUPRAFA IEI CONDENSULUI PE SUPRAFA A INTERIOARA A INTERIOARA
T
si
Temperatura suprafetei interioare [C];
t
r
Temperatura punctului de rou [C].
r si
T t >
VERIFICAREA CONDENSULUI VERIFICAREA CONDENSULUI N INTERIORUL ELEMENTULUI N INTERIORUL ELEMENTULUI
m
w
Masa de ap condensat n perioada rece a anului;
m
v
Masa de ap evaporat n perioada cald a anului.
0 s
v w
m m
Wadmis W
ef
A s A
AW
ef
Procentul de ap condensat n perioada rece a anului;
AW
admis
Procentul de ap admis.
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
CALCULUL TEMPARATURII PE SUPRAFA CALCULUL TEMPARATURII PE SUPRAFA A PERETELUI A PERETELUI
Curs 1
Universitatea Politehnica din Timisoara, Romania
Temperatura pe suprafa Temperatura pe suprafa a interioar a interioar a elementelor de construc a elementelor de construc ii ii
f f r r pun pun i termice i termice n sec n sec iunile curente se calculeaz iunile curente se calculeaz cu formula cu formula: :
R
T T
T T
i
e i
i si

=
o
) (
T
si
Temperatura suprafetei interioare [C];
T
i
Temperatura interioar [C];
Te Temperatura exterioar [C];
o
i
Coeficient superficial de transfer termic pe suprafaa interioar [C];
R Rezistena la transfer termic total [m
2
K/W];
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
VALORILE COEFICIEN VALORILE COEFICIEN ILOR DE TRANSFER TERMIC FUNC ILOR DE TRANSFER TERMIC FUNC IE IE
DE DIREC DE DIREC IA FLUXULUI C IA FLUXULUI C LDURII LDURII
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
TEMP TEMPE ERATURA PUNCTULUI DE ROU RATURA PUNCTULUI DE ROU
Curs 1
Universitatea Politehnica din Timisoara, Romania
FUNC FUNC IE DE IE DE
T
i
Temperatura interioar [C];

i
Umiditatea relativ a aerului [%];
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
TEMPERATUR TEMPERATURA PUNCTULUI DE ROU A PUNCTULUI DE ROU (C107/3 (C107/3 2006) 2006)
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
CONDENSUL IN INTERIORUL ELEMENTULUI CONDENSUL IN INTERIORUL ELEMENTULUI
Curs 1
Universitatea Politehnica din Timisoara, Romania
FUNC FUNC IE DE IE DE
p
v
> p
s
p
v
Presiunea vaporilor n interiorul elementului [Pa];
p
s
Presiunea de saturaie a vaporilor n element [Pa];
f (T
j
) Funcie de temperatur [C];
DAC p
v
= p
s
Condens ntr-o seciune vertical
DAC p
v
> p
s
Condens n perete pe o suprafa
FIZICA CONSTRUCTIILOR FIZICA CONSTRUCTIILOR - - AN II AN II
VARIATIA TEMPERATURII IN ELEMENTUL DE CONSTRUCTIE VARIATIA TEMPERATURII IN ELEMENTUL DE CONSTRUCTIE
Curs 1
Universitatea Politehnica din Timisoara, Romania
R
R T T
T T
j e i
i j

=
) (
T
j
Temperature la faa seciunii stratului j [C];
T
i
Temperatura interioar [C];
o
i
Coeficientul superficial pe suprafaa interioar [C];
R Rezistena total la transfer termic [m
2
K/W];