You are on page 1of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.

RTN380 Microwave Products Field Test Proposal

Reference: Version: Date:

{Reference} V3.0 3th Feb 2013

................................................... /................. Signature / Date: ................................................... /................. ................................................... /.................

13 August 2013

Commercial in Confidential

Page 1 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Contents
1 OVERVIEW ....................................................................................................4
1.1 Introduction .....................................................................................................................................4 1.2 Reference Documents.......................................................................................................................4

2 EQUIPMENT LIST..........................................................................................5
2.1 Equipments under test.....................................................................................................................5 2.2 Instruments for testing....................................................................................................................5

3 FIELD TRIAL DESCRIPTION........................................................................6


3.1 Maps of field trial.............................................................................................................................6

4 FIELD TEST SUMMARY................................................................................7


4.1 Radio link .........................................................................................................................................7

5 FIELD TEST CASE........................................................................................8


5.1 PM testing ........................................................................................................................................8 5.1.1 PM testing of Eth service with difference frames size................................................................8 5.2 Configuration Test in field............................................................................................................10 5.2.1 IF Configuration........................................................................................................................10 5.2.2 Radio configuration...................................................................................................................13 5.3 Service Test in Field.......................................................................................................................16 5.3.1 E-Line Services..........................................................................................................................16 5.3.1.1 Point-to-Point Transparently Transmitted E-Line Services...............................................16 5.3.1.2 VLAN-Based E-Line Service.............................................................................................20 5.3.2 Transmission Delay Measurement in Field...............................................................................24 5.3.2.1 Ethernet service round-trip delay.......................................................................................24 5.3.3 Transmission Capacity Measurement in Field..........................................................................25 5.3.3.1 Ethernet service throughput2.5Gbps.............................................................................25 5.3.3.2 Ethernet service throughput................................................................................................27 5.3.4 Quality of Service (Qos)............................................................................................................30 5.3.4.1 Eth Traffic schedule according to VLAN priority.............................................................30 5.3.5 Service Stability.........................................................................................................................35 5.3.5.1 Ethernet service transmission stability test........................................................................35 5.4 Operation and Maintenance Test in Field by LCT.....................................................................37 5.4.1 Maintenance..............................................................................................................................37 5.4.1.1 Checking the NE status......................................................................................................37 5.4.1.2 Browsing the Current Alarms.............................................................................................40 5.4.1.3 Browsing the History Alarms.............................................................................................43 5.4.1.4 Browsing the Transmit Power and Receive Power............................................................46 5.4.2 Emergency Maintenance...........................................................................................................48 5.4.2.1 IEEE 802.1ag ETH OAM test............................................................................................48 5.4.3 Y1731 Test.................................................................................................................................57 5.4.3.1 LM Test..............................................................................................................................57

13 August 2013

Commercial in Confidential

Page 2 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5.4.3.2 DM Test..............................................................................................................................59 5.4.3.3 FDV Test............................................................................................................................62 5.5 1+1 HSB and 2+0 Scenario Test....................................................................................................63 5.5.1 1+1 HSB Scenario Test.............................................................................................................63 5.5.2 2+0 Scenario Test......................................................................................................................66

13 August 2013

Commercial in Confidential

Page 3 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

1
1.1

OVERVIEW
Introduction

This document describes the field test proposal used by Huawei microwave radio transmission platform RTN 300 series. The field trial information and microwave planning parameters are descripting in this document, and most contents of them should be completed after meeting with costumers. Every test case in this document can be applied to one or more field trial, and every field trial may implement with one or more test case. Chapter 4 descript the combination of radio link and test case.

1.2

Reference Documents
< RTN 380 V100R001 Feature Description > < RTN 380 V100R001 Configuration Guide > < RTN 380 V100R001 Maintenance Guide >

13 August 2013

Commercial in Confidential

Page 4 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

2
2.1
RTN380 U2000

EQUIPMENT LIST
Equipments under test
Products

Version
V1R1 V1R8C00 V1R8C00 V1R3/R5

Quantity
2 1 1 2

U2000WebLCT RTN900 series

2.2

Instruments for testing


Model and Serial number Valid of Calibration

Type Ethernet analyzer

Manufacturer Test center

Quantity 1

13 August 2013

Commercial in Confidential

Page 5 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

3
3.1

FIELD TRIAL DESCRIPTION


Maps of field trial

According to the real site information Site A Site C

Radio link

13 August 2013

Commercial in Confidential

Page 6 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

4
4.1
No 1 2 1+0 1+1

FIELD TEST SUMMARY


Radio link
Test Items Notice

13 August 2013

Commercial in Confidential

Page 7 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5
5.1

FIELD TEST CASE


PM testing
5.1.1 PM testing of Eth service with difference frames size
This case to verify the radio transmission stability of Ethernet service with difference frames size.

Test Consideration

Test Bench

1. Create radio link with required parameters. 2. Configure E-LINE services over radio link. Test Procedure 3. Loopback relevant Ethernet ports on remote site. 4. Configure the test analyzer with difference frames:96,101,512,1024,1518,1522. 5. Check the results. Test Results Radio link information: link 1 Radio Channel Spacing: 500MHz Packet length 96 Bytes Modulation Scheme: 64QAM Rate measured value

13 August 2013

Commercial in Confidential

Page 8 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

101 Bytes

512 Byte

1024 Bytes

1518 Bytes

13 August 2013

Commercial in Confidential

Page 9 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

1522 Bytes

The long test should be no packets loss. Expected Results

Remarks: signature

5.2

Configuration Test in field


5.2.1 IF Configuration
When a new radio link to be installing, the MW engineer should go to the site and configure radio parameters according to the network planning profile.

Test Consideration

This case to verify that same basic parameters can be query and configurable by LCT in field. Be careful, some operations in this case may interrupt the radio link.

Test Bench

Test Procedure

1. Establish a radio link with required parameters.

13 August 2013

Commercial in Confidential

Page 10 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

2. Query the Radio configuration on LCT and check parameters list below are correct: a. Channel space b. Manually specified modulation c. Link ID

d. Received link id 3. Apply a new channel space and query the channel space should be update. ( before do this, you must ensure the adjacent channel is free) 4. Check the radio link is broken, then configure the channel space to initial value and check the radio link should restore. 5. Apply a new modulation scheme and query the modulation should be update. 6. Check the radio link is broken, then configure the modulation to initial and check the radio link should restore. 7. Apply a new Link ID and check the received link id on remote site should equal to this new ID. 8. Configure the Link ID to initial value and check the received link id on remote site should change back.

Radio link information: link 1 Radio Channel Spacing: 500MHz Actions Query the channel space Test Results Query the modulation scheme Query the Link ID Query the received Link ID Modify the channel space Modify the modulation scheme Modify the Link ID Reason for Failure: Remarks: Radio link ID Modulation Scheme: 16QAM Results OK OK OK OK OK OK OK

13 August 2013

Commercial in Confidential

Page 11 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

IF Channel:

13 August 2013

Commercial in Confidential

Page 12 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Modulation mode:

signature

5.2.2
Test Consideration

Radio configuration
When a new radio link to be installing, the MW engineer should go to the site and configure radio parameters according to the network planning profile. This case to verify that same basic radio parameters can be query and configurable by LCT in field. Be careful, some operations in this case may interrupt the radio link.

Test Bench

Test

1. Establish a radio link with required parameters.

13 August 2013

Commercial in Confidential

Page 13 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

2. Query the raido configuration on LCT and check parameters below are correct: a. Actual transmit frequency b. Actual receive frequency c. Actual transmit power

d. Actual receive power e. Actual transmit status 3. Configure a new transmit frequency and query the actual value should be update to the new frequency. ( before do this, you must ensure this new frequency is free and no any other radio using this frequency on the same path) Procedure 4. Check the radio link is broken, then configure the transmit frequency to the initial value and check the radio link should restore. 5. Configure a new transmit power and query the actual value should be update to the new level 6. Check the receive power on remote site is changed, then configure the transmit power to the initial level and check the receive power on remote site is change back to the initial level. 7. Mute the radio and query the actual transmit status is mute, check the radio link will interrupt. 8. Unmute the radio and query the actual transmit status is mute, check the radio link will restore.

Radio link information: link 1 Radio Channel Spacing: 500MHz Actions Query the actual transmit frequency Test Results Query the actual receive frequency Query the actual transmit power Query the actual receive power Modify the transmit frequency Modify the transmit power Mute the radio Unmute the radio Reason for Failure: Remarks: TX frequency: Modulation Scheme: 64QAM Results Ok Ok Ok Ok Ok Ok Ok Ok

13 August 2013

Commercial in Confidential

Page 14 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

TX power:

RX power:

TX mute:

signature

13 August 2013

Commercial in Confidential

Page 15 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5.3
5.3.1
5.3.1.1

Service Test in Field


E-Line Services
Point-to-Point Transparently Transmitted E-Line Services
The point-to-point transparently transmitted E-Line services are the basic E-Line model. Point-to-point transmission does not involve service bandwidth sharing, service isolation, or service distinguishing; instead, Ethernet services are transparently transmitted between two service access points. in this manner, the transmission link is private This case to verify the transparently transmitted E-line services can be done on RTN equipment.

Test Consideration

Test Bench

1. Establish a radio link with required parameters. 2. Configure an E-Line service with null source VLAN and sink VLAN. Test Procedure 3. Create an IP streams on Ethernet analyzer with or without VLAN. 4. Configure the transmit rate less than the throughput in current radio mode. 5. Start transmit, check received packets without any loss.

Radio link information: link 1 Test Results Radio Channel Spacing: 500MHz Ethernet Services IP Stream without VLAN IP Stream with VLAN Reason for Failure: Remarks: Modulation Scheme: 16QAM Result Pass through Pass through

13 August 2013

Commercial in Confidential

Page 16 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Configuration:

13 August 2013

Commercial in Confidential

Page 17 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Traffic with Vlan:

13 August 2013

Commercial in Confidential

Page 18 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Traffic without Vlan:

Result :

13 August 2013

Commercial in Confidential

Page 19 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.3.1.2

VLAN-Based E-Line Service


VLANs can be used to separate E-Line services. With the VLAN technology, multiple E-Line services can share one physical channel. These services are VLAN-based ELine services This case to verify the VLAN-Based E-line services can be done on RTN equipment.

Test Consideration

Test Bench

Test Procedure

1. Establish a radio link with required parameters. 2. Loopback relevant ports on remote site.

13 August 2013

Commercial in Confidential

Page 20 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

3. Configure an E-Line service from port 1 of local site to port 1 of remote site through radio link with Vlan ID equal to 100. 4. Create an IP streams on the analyzers port which connect to port 1 of local site with VLAN id equal to 100200. 5. Start transmits with appropriate rate, check received packets on port 1.

Service Model:

Service 1 can pass through the radio link. And service 2 should be blocked.

Radio link information: link 1 Test Results Radio Channel Spacing: 500MHz Ethernet Services IP service 1 (Vlan id: 100) IP service 2 (Vlan id: 200) Reason for Failure: Remarks: Configuration: Modulation Scheme: 256QAM Result Pass block

13 August 2013

Commercial in Confidential

Page 21 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Traffic with vlan 100:

13 August 2013

Commercial in Confidential

Page 22 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Traffic with vlan 200

13 August 2013

Commercial in Confidential

Page 23 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.3.2
5.3.2.1

Transmission Delay Measurement in Field


Ethernet service round-trip delay
The Ethernet service transmission on the radio link. This case to measure the round-trop delay of Ethernet service.

Test Consideration

Test Bench

1. Create radio link with required parameters. Test Procedure 2. Configure E-LINE services over radio link. 3. Loopback relevant Ethernet ports on remote site. 4. Measure the latency with required packet length.

Radio link information: link 1 Radio Channel Spacing: 500MHz Test Results Packet length 64 Bytes 128 Bytes Modulation Scheme: 64QAM Round-trip delay Notes in remarks Notes in remarks Notes in remarks

13 August 2013

Commercial in Confidential

Page 24 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

The value is the one direction trip latency in the talbe.

Expected Results

Result :

Remarks:

signature

5.3.3
5.3.3.1

Transmission Capacity Measurement in Field


Ethernet service throughput 2.5Gbps
This case to verify the maximum radio transmission capacity of Ethernet service can reach 2.5Gbps.

Test Consideration

13 August 2013

Commercial in Confidential

Page 25 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Test Bench

1. Create radio link with required parameters. Test Procedure 2. Configure E-LINE services over radio link. 3. Loopback relevant Ethernet ports on remote site. 4. Measure the throughput with 64bits packet length on the highest modulation. Test Results Reason for Failure: Throughput : The maximum radio transmission capacity can reach 2.490Gbps

Remarks:

signature

13 August 2013

Commercial in Confidential

Page 26 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5.3.3.2

Ethernet service throughput


This case to verify the radio transmission capacity of Ethernet service can reach to the guaranteed value in the products specification.

Test Consideration

Test Bench

6. Create radio link with required parameters. Test Procedure 7. Configure E-LINE services over radio link. 8. Loopback relevant Ethernet ports on remote site. 9. Measure the throughput with required packet length.

Radio link information: link 1 Radio Channel Spacing: 500MHz Test Results Packet length 64 Bytes 128 Bytes Expected Results Modulation Scheme: 64QAM Throughput measured value More than 1G More than 1G More than 1G

13 August 2013

Commercial in Confidential

Page 27 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Remarks:

13 August 2013

Commercial in Confidential

Page 28 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 29 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.3.4
5.3.4.1

Quality of Service (Qos)


Eth Traffic schedule according to VLAN priority
In some situations, the 3G base site using different VLAN priority to identify different services (e.g. voice, HSDPA etc) with same VLAN ID. In this manner, the transmit equipment should schedule different services according to VLAN priority.

Test Consideration

This case to verify schedule the Ethernet services according to VLAN priority in RTN equipment. In this test case, we are considering three kinds of condition to verify this feature, the first one is a basic scenario that without congestion, the second one is got congestion and restore in case of the transmission rate change of one or more services changing, the last one is got congestion and restore in case of radio transmission capacity change (e.g. AM down shift and up shift).

13 August 2013

Commercial in Confidential

Page 30 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Test Bench

Service Model:

Test Procedure

1. Establish a radio link with required parameters. 2. Connecting the GE port of Ethernet analyzer to NE. 3. Configure an E-Line service with VLAN ID 100 between local and remote sites. 4. Loopback the service port on remote site. 5. Create a new port policy with required schedule policy (e.g. ALL queues are SP). 6. Configure traffic classification according to the VLAN priority and map them to different queues. 7. Apply the policy to relevant ports. 8. Create 4 IP streams on the test port of Ethernet analyzer with same VLAN ID and with different VLAN priority. Condition 1 : 1. Setting the transmit rate for every stream and keep the amount transmit rate is less than radio transmission capacity. 2. Start transmit all services, check the actual received rate of every stream is equal to the transmit rate, that means all services are transmit through the radio link correctly. Condition 2: 1. Increase the transmit rate of stream1till the radio getting congestion. 2. The low priority should be lost. 3. Restore the transmit rate of stream 1. 4. Start transmit all services, check the actual received rate of every test port is

13 August 2013

Commercial in Confidential

Page 31 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

equal to the transmit rate, that means all services are transmit through the radio link correctly.

Radio link information: link 1 Radio Channel Spacing: 500MHz IP streams configuration: Stream1: 128byte, Vlan ID 100, VLAN Pri 7, Stream2: 128byte, Vlan ID 100, VLAN Pri 5, Stream3: 128byte, Vlan ID 100, VLAN Pri 3, Stream4: 128byte, Vlan ID 100, VLAN Pri 1, Condition 1: Non-Congestion Ethernet Services Test Results Stream1 Stream2 Stream3 Stream4 AMOUNT Actual Transmitting Rate 100M 100M 100M 100M 400M Actual Receiving Rate 100M 100M 100M 100M 400M Modulation Scheme: QPSKS

Condition 2: Congestion by transmission rate of streams increased Ethernet Services Stream1 Stream2 Stream3 Stream4 AMOUNT Expected Results Remarks: Configuration : The packet losing of each service is correct by different VLAN priority. Actual Transmitting Rate (Congestion / Restore) 250/350/424 100 100 100 Actual Receiving Rate (Congestion / Restore) 250/350/424 100/74/0 74/0/0 0/0/0

13 August 2013

Commercial in Confidential

Page 32 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 33 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 34 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature signature

5.3.5
5.3.5.1

Service Stability
Ethernet service transmission stability test
This case to verify the reliability of Ethernet service that transmits through radio link for a long test period.

Test Consideration

13 August 2013

Commercial in Confidential

Page 35 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Test Bench

1. Establish a radio link with required parameters. Test Procedure 2. Configure Ethernet service. 3. Make PER measurement for a period of more than 24 hrs.

Radio link information: link 1 Radio Channel Spacing: 500MHz Test Results Service Type
Ethernet Stream1

Modulation Scheme: 16QAM Start Date/Time


2013-02-07

Service Description
Packets length: 101 Throughput: 2G Vlan-ID: 100 Priority: 0

Stop Date/Time
2013-02-09

Results
OK

Reason for Failure: Remarks:

13 August 2013

Commercial in Confidential

Page 36 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.4
5.4.1
5.4.1.1

Operation and Maintenance Test in Field by LCT


Maintenance
Checking the NE status
This case to verify checking the NE status in field by LCT.

Test Consideration

Test Bench

Test Procedure

1. In NE List, query communication status of an NE, communication status needs to be Normal. 2. Check Login Status of an NE. If the Login Status column of an NE is Not Logged In, log in to the NE. a) Select an NE, and then click NE Login, the NE Login dialog box is

13 August 2013

Commercial in Confidential

Page 37 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

displayed. b) Enter a user name in User Name and a password in Password. c) The user name is lct by default. The password for the user lct is Changeme_123 by default.

Click OK. After you log in to the NE successfully, Login Status in NE List changes to Logged In.

Radio link information: Radio link 1 Test Results Actions NE login Login status after login Reason for Failure: Remarks: OK OK Results

13 August 2013

Commercial in Confidential

Page 38 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 39 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.4.1.2

Browsing the Current Alarms


This case to verify browsing the current alarms and saving them to a field by LCT.

Test Consideration

13 August 2013

Commercial in Confidential

Page 40 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Test Bench

1. In the NE Explorer, select the required NE from the Object Tree, and then click the icon on the toolbar. You can also click an alarm indicator on the toolbar to display the alarms of the specific severity. From left to right, the alarm indicators and corresponding alarm severities are as follows: Red: critical alarm Test Procedure Orange: major alarm Yellow: minor alarm Purple: warning Light blue: abnormal event 2. Browse the displayed alarms. 3. If there are newly generated alarms after the last maintenance, select the newly generated alarms, record the details of these newly generated alarms, and then notify the troubleshooting personnel to clear these alarms in time. 4. Click Save As, a text file that lists the current alarms is displayed in Internet Explorer.

Radio link information: Radio link 1 Radio Channel Spacing: 500MHz Test Results Actions Browsing the Current alarms Save the Current alarms to a file Plaster the current alarms file in here. Reason for Failure: Ok Ok Modulation Scheme: 16QAM Results

13 August 2013

Commercial in Confidential

Page 41 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Remarks:

signature

13 August 2013

Commercial in Confidential

Page 42 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5.4.1.3

Browsing the History Alarms


This case to verify browsing the history alarms and saving them to a field by LCT.

Test Consideration

Test Bench

1. In the NE Explorer, select the required NE from the Object Tree, and then click the icon on the toolbar.

2. Click the Browse History Alarms tab. 3. Click Filter, The Filter dialog box is displayed. Test Procedure 4. Specify Rising Time and Cleared Time, and then click Filter. 5. The time span starts from the time when the last history alarm browsing operation was performed to the current time. 6. Browse the filtered history alarms. 7. Click Save As, a text file that lists the history alarms is displayed in Internet Explorer.

Radio link information: Radio link 1 Test Results Radio Channel Spacing: 500MHz Actions Browsing the History alarms Save the History alarms to a file Reason for Failure: Remarks: OK OK Modulation Scheme: 16QAM Results

13 August 2013

Commercial in Confidential

Page 43 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 44 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 45 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.4.1.4

Browsing the Transmit Power and Receive Power


This case to verify browsing the history transmits power and receives power and then draws the power curve by LCT.

Test Consideration

Test Bench

1. GO to the main topology, press the radio link and select the radio link monitor. Test Procedure 2. Choose the 15min or 24h performance, and query valve. 3. Check the curve of the TX power and RX power.

Radio link information: Radio link 1 Test Results Radio Channel Spacing: 500MHz Actions Browsing the transmit power Browsing the receive power Reason for Failure: Remarks: OK OK Modulation Scheme: 64QAM Results

13 August 2013

Commercial in Confidential

Page 46 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 47 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

5.4.2
5.4.2.1

Emergency Maintenance
IEEE 802.1ag ETH OAM test
The IEEE 802.1ag OAM focuses on the maintenance of end-to-end Ethernet links. It realizes the sectional and segmental management over the service flow by specifying the maintenance domain, maintenance association, and maintenance point.

Test Consideration

Test Bench

Test Procedure

1. Create radio link with required parameters. 2. Creating a maintenance domain (MD). 3. Creating a maintenance association (MA). 4. Creating an MEP point. 5. Creating remote MEPs in an MA. 6. Creating MIP. 7. Performing LB and LT testing on local site.

13 August 2013

Commercial in Confidential

Page 48 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Radio link information: Radio link 1 Test Results Radio Channel Spacing: 500MHz Actions LB test for a good radio link LT test for a good radio link Reason for Failure: Remarks: Modulation Scheme: 64QAM Results pass pass

13 August 2013

Commercial in Confidential

Page 49 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 50 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 51 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 52 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 53 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 54 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 55 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

signature

13 August 2013

Commercial in Confidential

Page 56 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

5.4.3
5.4.3.1
Test Purpose

Y1731 Test

LM Test
Test the Ethernet OAM function.

Test Topology

(1) Setup the configuration according above figure.. (2) Configure Ethernet service from NE1 to NE2. Test Steps (3) Create MEP1 at port of NE1, and set the MPID (4) Create MEP2 at port of NE2, and set the MPID, (5) Set the frame loss test parameters and check the result. Expected Results Pass / Fail Remarks Frame loss test work normally and the result is the same with the tester. pass

13 August 2013

Commercial in Confidential

Page 57 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

13 August 2013

Commercial in Confidential

Page 58 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Signature

5.4.3.2

DM Test
Test the Ethernet OAM function.

Test Purpose

13 August 2013

Commercial in Confidential

Page 59 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Test Topology

(1) Setup the configuration according above figure.. (2) Configure Ethernet service from NE1 to NE2. Test Steps (3) Create MEP1 at port of NE1, and set the MPID (4) Create MEP2 at port of NE2, and set the MPID, (5) Set the frame delay test parameters and check the result. Expected Results Pass / Fail Frame delay test work normally and the result is the same with the tester . Latency: 70us----150us one way pass

Remarks

13 August 2013

Commercial in Confidential

Page 60 of 68

Huawei Microwave Radio Product RTN 900 V100R003 Test Proposal V1.0

Signature

13 August 2013

Commercial in Confidential

Page 61 of 68

RTN900 Microwave Products Field Test Proposal

5.4.3.3

FDV Test
Test the Ethernet OAM function.

Test Purpose

Test Topology

(6) Setup the configuration according above figure.. (7) Configure Ethernet service from NE1 to NE2. Test Steps (8) Create MEP1 at port of NE1, and set the MPID (9) Create MEP2 at port of NE2, and set the MPID, (10)Set the frame delay test parameters and check the result. Expected Results Pass / Fail Frame delay test work normally and the result is the same with the tester. Less than 10us. pass

Remarks

13 August 2013 68

Commercial in Confidential

Page

62 of

RTN900 Microwave Products Field Test Proposal

5.5
Test Purpose

1+1 HSB and 2+0 Scenario Test


5.5.1 1+1 HSB Scenario Test
To verify the HSB switching working normally.

Test Topology

(1) Create the test environment as shown in the diagram above. (2) Configure 1+1 HSB on the RTN 380, RTN380 NE1 is main unite, NE2 is standby. And RTN380 NE3 is main unite,NE4 is standby. (3) Configure Two Ethernet service between NE1 and NE3 with vlan 100 and the vlan 200. (4) Setting the Ethernet analyzer, send traffic with vlan 100, and vlan 200. (5) Check the service status. (6) Cut off the main radio link, the service should be switch to the standby.

Test Steps

Expected Results Pass / Fail

Remarks:

This scenario requires the switch or the upper device support static nonsharing mode. If the switch can support the LAG configuration, the HSB will work normally. But in current test environment, the switch can not support non-sharing mode, so another solution have to be used to instead. Solution 2: Configure ports protection on switch side. This solution switching time is more than 3s. Test topology:
Commercial in Confidential Page
63 of

13 August 2013 68

RTN900 Microwave Products Field Test Proposal

Before switching

After switching

13 August 2013 68

Commercial in Confidential

Page

64 of

RTN900 Microwave Products Field Test Proposal

So for one link, it can transmit 1Gbps service and for each port is 500Mbps

Signature

13 August 2013 68

Commercial in Confidential

Page

65 of

RTN900 Microwave Products Field Test Proposal

5.5.2
Test Purpose

2+0 Scenario Test


To verify the 2+0 configuration can supply lager bandwidth and higher transmission capacity.

Test Topology

(1) Create the test environment as shown in the diagram above; (2) Configure Manual Sharing LAG on switch side; (3) Configure four Ethernet service between NE1 and NE3 with vlan 100, 200, 300, and 400. (4) Connect the switch and the tester with 10G port and set the Ethernet analyzer, send Eth traffic. (5) Check the service status.

Test Steps

Expected Results Pass / Fail

Remarks:

This scenario requires the switch or the upper device support manual sharing mode. If the switch can support the LAG configuration, the 2+0 will work normally. In current test environment, the switch can not support banding one optical and electoral ports in one sharing LAG, so we test another solution. Test topology:
Commercial in Confidential Page
66 of

13 August 2013 68

RTN900 Microwave Products Field Test Proposal

Link 1 channel bandwidth and modulation is 500MHz16QAM ,capacity is 1.3Gb. And the RX power is -51dBm and -47dBm. Link 2 channel bandwidth and modulation is 500MHz16QAM,capacity is 1.3GB. And the Rx power is -58dBm and -56dBm So for 2+0 scenario, 2Gbps service can be transmitted and each port 500Mbps

13 August 2013 68

Commercial in Confidential

Page

67 of

RTN900 Microwave Products Field Test Proposal

Signature

13 August 2013 68

Commercial in Confidential

Page

68 of

You might also like