You are on page 1of 12

Pump

Vertical Mixed / Axial Flow

Hyundai

Circulating Water Pump for Yonghung Thermal Power Plant, Units 1 & 2, KOREA (1100m3 /min X 20m X 4600kW, Model 3000VKANM, Variable pitch vane type)

Superior Quality, Higher Performance


Advantage of Hyundai Vertical Mixed / Axial Flow Pump

 tability in capacity, head and shaft power enables S continuous operation without noise or vibration, even under circumstances where a wide variation of capacity is required.

C  omparative low revolution speed of pump attains high suction performance, eliminating cavitation problem, and is suitable for a system of a wide variation of water level. S  uperior quality and high performance. No  fear for surging and overload.

L  arge variety of options to meet all customers requirements in combination of materials and constructions.

Application

Power Plant :  Circulation water pump Condensate pump Sea water lift pump Desalination Plant :  Brine recirculation pump Brine blow-down pump Distillate pump Sea water intake pump Sewage Treatment Plant :  Influent pump Effluent pump

City Water :  Intake pump Transfer pump Other Water Works :  Rain water drainage pump Irrigation pump Fire fighting pump Dock dewatering pump

Hyundai Vertical Mixed / Axial Flow Pump 1

General Specification
Design factor Discharge bore Flow rate Head Liquid Discharge connection Submerged bearing Thrust bearing Seal Standard 400mm (16 in.)~ 1500m3/hr (6600 US GPM)~ 4m (13 ft)~ Fresh water, Sewage, Sea water KS, JIS, ISO, DN, AWWA Rubber bearing (water lubrication) Anti-friction bearing Gland Packing Base, Anchor bolt, Drain pipe, Coupling Plain end, Any standard Option

Dry bearing Tilting pad bearing Mechanical seal  ubber bearing lubrication R system, Suction strainer, Pressure gauge, Auto air vent valve, Tools, and etc.

Accessories

Vertical Mixed / Axial Flow Pump

Shop test of Kudankulam Nuclear Power Plant, INDIA Sea Water Pump (735.5m3/min X 15.9m X 3200kW, Model 2200VKAM)

Hydraulic Coverage

[Note] Pumps rating over this range are available also. colored section shows the type of pump of which thrust is supported by pump.

Pump Model Name 2000 VK A M


M : Motor drive GE : Engine drive through gear GT : Turbine drive through gear N : Pull-out type A : Vane adjustable Number of stage or None (1 stage) VK : Vertical Mixed Flow Pump VA : Vertical Axial Flow Pump Discharge bore in mm

Hyundai Vertical Mixed / Axial Flow Pump 3

Construction

12 11 10 9 3

Thrust bearing in pump, enclosed line shaft

4 7
Open line shaft Fabricated column pipe

8 6

2
Low head impeller

5 1

Axial flow pump

2 stage construction

Materials
No. 1 2 3 4 5 6 7 8 9 10 11 12 Part Suction bell Bowl Discharge elbow Column pipe / Barrel Impeller Shaft Sleeve Shaft enclosing tube Bearing Gland Packing Flexible coupling Driver pedestal Carbonized fiber Gear type or etc. Carbon steel Fresh Water Sewage Sea Water Low alloy cast iron Ni-resist D2, Cast iron, Ductile cast iron, Rolled steel Bronze, 304 S.S. Carbon steel 304 S.S. Cuttless rubber Bronze 402 S.S. Aluminium bronze, 316 S.S., Duplex S.S. Aluminium bronze, 316 S.S., Duplex S.S. Duplex S.S. 316 L, Duplex S.S. 316 S.S., Duplex S.S. Cuttless rubber, Teflon, etc. Carbonized fiber

Cast iron, Ductile cast iron

 Selection of material requires careful study of the properties of the liquid handled and the operating conditions, and etc.

Pull out elements of Vertical Mixed Flow Pump (Model 2000VKNM, Pull-out type)

Hyundai Vertical Mixed / Axial Flow Pump 5

Outline Dimensions
Unit : mm

Basic Type

Pump Discharge Bore 350 (14) 400 (16) 450 (18) 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40) 1100 (44) 1200 (48) 1350 (54) 1500 (60) 1650 (66) 1800 (72) 2000 (80) 2200 (88) 2400 (96)

A 445 495 550 600 725 830 930

J 25 30 30 30 40 40 40 40 50 50 50 50 50 50 50 50 50 50

K 22 24 24 24 24 24 24 30 30 30 30 36 36 36 36 36 42 42

V 55 60 60 60 90 90 90 90

N 4 4 6 6 6 8 8 8 8 8 8 12 12 16 18 20 20 24

400 1500 430 450 1600 500 500 1800 500 550 1900 500 650 2300 630 750 2400 630 850 2500 630

750 1150 1150 850 1250 1260 950 1400 1360 1050 1500 1460 1150 1700 1570 1350 1850 1770 1500 2000 1920 1700 2200 2120

1040 950 2700 630 1150 1050 2800 800 1255 1150 3000 800 1355 1250 3100 800 1510 1400 3300 800 1660 1500 3500 800 1800 1600 3700 1000 1950 1800 3900 1000 2150 2000 4300 1000 2350 2200 4500 1000 2550 2400 4800 1300

100 1850 2450 2280 100 1950 2530 2380 100 2050 2610 2480 100 2150 2740 2580 100 2350 2900 2780 120 2600 3200 3300 120 2700 3600 3700 120 2850 3800 3900 150 3200 3960 4100 150 3500 4250 4300

Pump Sump Dimensions


Foundation

Performance Test Facility


Test Capacity : 93,240 m3/hr(Max. Flow Rate) Electricity Capacity : 23000kVA at 60Hz and 3500 kVA at 50Hz Voltage : 13800, 6600, 3300, 440, 380, 220 Volt

Sump model test layout

Computer aided dynamic balance test of impeller

For Making Inquiries


In sending your inquiries for estimate or planning, please forward following:

Capacity, Head. Application of pump, construction, and installation method. Water quality and temperature. Driver, type of driver system (Frequency of available electricity). Distance from installed level of pump to the lowest water level. Materials if you have any special requirements.

Hyundai Vertical Mixed / Axial Flow Pump 7

Major Performance Records


No. CUSTOMER/PROJECT RAYTHEON, USA / ILIJAN 1200MW COMBINED CYCLE POWER PLANT CIRCULATION WATER PUMP SPECIFICATION MATERIAL MODEL Q'TY Q(M3/ H(M) N(rpm) L(kW) CASING IMPELLER SHAFT Min) 1800 VKM 4 424.07 16.76 16.76 16.76 A743CF3M A743CF3M A439D2 A743CF3MN A743CF3M A743CF3M SLEEVE A743CF3M A743CF3M A743CF8M DELIVERY REMARKS

'00.09 #5 : '01.07 #6 : '01.09 '03.10

PHILIPPINE

2 3 4

KHNP / ULCHIN #5 & 6 NUCLEAR POWER 1800 PLANT (1000MW 2 UNITS), VKNM CIRCULATING WATER PUMP ALGERIA / SONATRACH COMPLEX GL2Z SEA WATER INTAKE PUMP ASE(ATOMSTROYEXPORT) / KUDANKULAM POWER PLANT SEA WATER INTAKE PUMP GECOL / BENGHAZI NORTH COMBINED CYCLE POWER PLANT MAIN CIRCULATING WATER PUMP GECOL / ZAWIA COMBINED CYCLE POWER PLANT, CIRCULATING WATER PUMP KOREA SOUTH-EAST POWER CO., LTD. / YONGHUNG THERMAL POWER PLANT, UNITS #3, 4 (870MW 2) CIRCULATING WATER PUMP HHI / MARAFIQ IWPP PROJECT CIRCULATING WATER PUMP FOR ALSTOM/ TKS CAS RIO DE JANEIRO BRAZIL POWER PLANT MAIN COOLING WATER PUMP 1800 VKNM 2200 VKAM 1800 VKNM 1500 VKNM

12 1 12

503.4 549 735.5

11 40.5 15.9

300 330 1000

1300 4600 3200

SUPER SUPER S.S. S.S. (SR 50A) (SR 50A) A743CF8M A743CF3MN A276316 A276S31803 A276S31803 A276S31803

KOREA ALGERIA INDIA

A743- '04.08 (6SETS) CF3MN '05.01 (6SETS) A890CD6MN A890CD6MN '05.08

583.33

18

370

2400

A890A890CD4MCU CD4MCU A890A890CD4MCU CD4MCU

LIBYA

306.67

26

493

1700

'06.02

LIBYA

3000 VKANM 1100 VKM 1800 VKM 1650 VKNM 1650 VKNM 1350 VKM

1217

23

222

5179

A743CF3MN

A743CF3MN

A276S31803 A276 S31803 A276S31803 A276S31803 A276S31803 A276S31803

A743CF3MN A890CD4MCU A890CD4MCU A890CD4MCU A240S31803 A890CD4MCU

#3: '06.08 #4: '06.10 '08.04 '08.05

KOREA VARI. PITCH VANE TYPE

8 9

3 2

183.22 15.43 516 14.5

443 273

600 1580

A890A890CD4MCU CD4MCU CD4MCU- A890316L CD4MCU A890A890CD4MCU CD4MCU A743CF3MN A743CF3MN

BRAZIL

POSCO E&C / NUEVA VENTANAS POWER 10 PROJECT MAIN CIRCULATING WATER PUMP FISIA ITALIMPIANTI / SHUAIBA NORTH 11 DESALINATION PROJECT SEA WATER SUPPLY PUMP 12 ALSTOM/ FUJAIRAH F2 POWER PLANT MAIN COOLING WATER PUMP

301.67 15.5

370

1050

'08.05

CHILE

5 4

378.78 324

32 20.75

410 425

2600 1450

'08.12 '09.04

KUWAIT U.A.E

A890A890CD4MCU CD4MCU

Circulating Water Pump for Taean Thermal Power Plant

Seawater Lift Pump for Taean Thermal Power Plant

Major Installation

Variable Pitch Vane Pump

Jebel Ali Gas Turbine & Desalination Station E

Circulating Water Pump for Zaiwa IWPP Project in Libya

CWP & ACWP of Marafiq IWPP Project in Saudi Arabia

Dock Dewatering Pump

Hyundai Vertical Mixed / Axial Flow Pump 9

www.hhi.co.kr www.hyundai-engine.com North America


New Jersey [1-201] TEL : 816-4080~2 FAX : 816-4083 Houston [1-281] TEL : 578-7097, 7802, 8216 994-5000~1 FAX : 578-8317/7330 Orlando [1-407] TEL : 249-7350 FAX : 275-4940

U.S.A.

PANAMA [1-507] TEL : 213-7657~9 FAX : 213-7660

Europe
London [44-20] TEL : 8741-0501 FAX : 8741-5620, 8834-7281 Oslo [1-47] TEL : 2241-0920 FAX : 2242-6671 Athens [1-30-210] TEL : 428-2992, 3 FAX : 428-2144

U.K.

Norway

Greece

The Netherlands
Rotterdam [1-31-10] TEL : 212-1567 FAX : 212-5134

HEAD OFFICE (KOREA) 1, Jeonha-dong, Dong-gu, Ulsan, 682-792 TEL. : +82) 52 202 6191~6199 FAX. : +82) 52 202 6190 E-mail : pump@hhi.co.kr SEOUL OFFICE (KOREA) 140-2, Gye-dong, Jongno-gu, Seoul, 110-793 TEL. : +82) 2 746 4681~4685 FAX. : +82) 2 746 4720

Moscow [1-7-495] TEL : 258-1381 FAX : 258-1382

Russia

Asia
Tokyo [1-81-3] TEL :  3211-4799, 0742~4, 2650, 4791 FAX : 3211-2093, 3216-0728 Osaka [1-81-6] TEL : 6261-5766~7 FAX : 6261-5818

Japan

SINGAPORE [1-65] TEL : 6337-2366 FAX : 6333-4680 INdia


Mumbai [1-91-22] TEL :  2496-6770~2, 6774 FAX : 2498-6020

Istanbul [1-90-212] TEL : 345-1261, 1262 FAX : 345-1263

Turkey

Middle East/Africa
Dubai [1-971-4] TEL : 425-7995 FAX : 425-7996

U.A.E.

ANGOLA

Luanda [1-244-222] TEL : 370669,370692 FAX : 399667

HHI-EMD VK / VA PUMP 2009-6 Contents subject to change without prior notice.

You might also like