You are on page 1of 7

Limitation of connectable modules/maximum configuration

Number of modules
The following modules are available for the ET 200S: interface modules, power modules,
electronic modules, RESERVE modules, technology modules, motor starters, and frequency
converters.
The number of modules you can insert is dependent on the interface module you are using:

Max. 12 modules with:

lM151-1 BASlC

lM151-1 COMPACT

Max. 63 modules with:

lM151-1 STANDARD

lM151-1 FO STANDARD

lM151-1 HlGH FEATURE

lM151-3 PN

lM151-3 PN FO

lM151-3 PN HlGH FEATURE


Bus length of the ET 200S
A maximum bus length of 2 m can be assigned for the ET 200S.
Deviations are noted in the properties of the interface modules.
Parameter length

For PROFlBUS DP: Depending on the PROFlBUS DP master you are using

For PROFlNET lO: Not relevant for maximum configuration


Address space

For PROFlBUS DP: Depending on the PROFlBUS DP master you are using

For PROFlNET lO: Not relevant


Maximum configuration per potential group
The number of modules that can be connected depends on the total current of all modules in
a potential group. This total current must not exceed the maximum current-carrying capacity
of the power modules or COMPACT modules you are using.
The total current is governed in large part by the digital output modules.
ET 200S
Limitation of connectable modules/maximum configuration
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=12431208459 5/14/2010
Table 1 Maximum configuration per potential group
Power modules/
COMPACT modules
Maximum current-carrying capacity
Power Module PM-E DC24V 10 A
Power Module PM-E DC24..48V 10 A
Power Module PM-E DC24..48V/AC24..230V

For 24 to 56.7 VDC

For 24 to 48/120/230 VAC


10 A
8 A
lM151-1 COMPACT 5 A, for l/O modules connected after the lM151-1
COMPACT
DP master 32-byte diagnostic message frame length
You can use the ET 200S with DP masters with a diagnostic frame length of 32 bytes because
you can set the length of the diagnostic frame in all the interface modules.
Reference
The relevant values can be found in the technical data for the respective modules.
ET 200S
Limitation of connectable modules/maximum configuration
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=12431208459 5/14/2010
Example of a configuration: Terminal modules for power modules
lntroduction
The following table shows how terminal modules for power modules can be used:
Table 1 Terminal modules for power modules
Terminal module Structure
TM-P15S22-01
TM-P15C22-01
TM-P15N22-01
Figure 1
TM-P15S23-A1
TM-P15C23-A1
TM-P15N23-A1
Figure 2
ET 200S
Example of a configuration: Terminal modules for power modules
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=12372577035 5/14/2010
Terminal module Structure
TM-P15S23-A0
TM-P15C23-A0
TM-P15N23-A0
Figure 3
TM-P30S44-A0
TM-P30C44-A0
ET 200S
Example of a configuration: Terminal modules for power modules
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=12372577035 5/14/2010
Terminal module Structure
TM-PF30S47-F1
ET 200S
Example of a configuration: Terminal modules for power modules
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=12372577035 5/14/2010
Example of a configuration
lntroduction
The following example describes how to design an ET 200S configuration:
ET 200S structure
An example design of an ET 200S configuration is shown in the following figure:
Figure 1 ET 200S structure
Configuration table and address space
The user is free to select the byte addresses of the inputs and outputs (if the configuration
software supports this). The bit addresses result automatically from the sequence of the
grouped modules.
The following table shows which modules have been grouped and the corresponding address
space.
Table 1 Configuration table and address space
Slot Module Grouping l/O address
lnputs Outputs
1 6ES7138-4CA01-0AA0 PM-E DC24V --- --- ---
2 6ES7131-4BB01-0AB0 2Dl DC24V yes 0.0 to 0.1
3 6ES7131-4BB01-0AB0* 2Dl DC24V 0.2 to 0.3
4 6ES7134-4FB01-0AB0 2Al U No 1 to 4
5 6ES7135-4GB01-0AB0 2AO l No 0 to 3
6 6ES7131-4BD01-0AA0* 4Dl DC24V yes 0.4 to 0.7
ET 200S
Example of a configuration
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=7388250123 5/14/2010
Slot Module Grouping l/O address
lnputs Outputs
7 6ES7132-4BD01-0AA0 4DO DC24V yes 4.0 to 4.3
8 6ES7132-4BB01-0AB0* 2DO DC24V 4.4 to 4.5
9 6ES7132-4HB01-0AB0* 2DO Rel. 4.6 to 4.7
10 6ES7134-4FB01-0AB0 2Al U No 5 to 8
11 6ES7135-4GB01-0AB0 2AO l No 5 to 8
12 6ES7138-4CA01-0AA0 PM-E DC24V --- --- ---
13 6ES7132-4BB31-0AB0 2DO DC24V yes 9.0 to 9.1
14 6ES7132-4BB31-0AB0* 2DO DC24V yes 9.2 to 9.3
15 6ES7138-4CB11-0AB0 PM-E AC230 --- --- ---
16 6ES7132-4FB01-0AB0* 2DO 230V yes 9.4 to 9.5
17 6ES7132-4FB01-0AB0* 2DO 230V yes 9.6 to 9.7
18 3RK1903-0BA00 PM-D --- --- ---
19 3RK1301-xxB00-0AA0 DS yes 9.0 to 9.3 10.0 to 10.3
20 3RK1301-xxB00-0AA0 *DS 9.4 to 9.7 10.4 to 10.7
21 3RK1301-xxB00-0AA0 DS yes 10.0 to 10.3 11.0 to 11.3
ET 200S
Example of a configuration
This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims
all liability for the completeness of this document. lt shall only be used for the user's own internal purposes. lt shall not be passed on to third parties. The complete
documentation can be found at:
https://www.automation.siemens.com/mdm/default.aspx?DocVersionld=12541585419&Language=en-US&Topicld=7388250123 5/14/2010

You might also like