ABB Genway Xiamen Electrical Equipment Co.,Ltd. 6-7F,No.23 Wanghai Road, Software Park 2, Lvling Road,Xiamen, China Tel : +86 592 5747 548 Fax: +86 592 5625 072 http//en.doorphone.cn
GENERAL CATALOGUE
This catalogue is for reference only,if there are any different with actual products due to upgrading,the explanation right is reserved to ABB (China) company.
Contents
BRIEF INTRODUCTION KIT OUTDOOR STATION INDOOR STATION ACCESSORIES SYSTEM DIAGRAM ACCESS CONTROL SYSTEM 03 09 22 28 44 52 66
BRIEF INTRODUCTION
A BRIEF OUTLINE OF THE CATALOGUE
03 Brief Introduction
Brief Introduction 04
Outdoor Stations
Choose the style of panel you want...
Depending on the type of building in which you are going to install the system, GENWAY offers you different styles of outdoor stations...
D5 SHELL
S2 SHELL
S5 SHELL
S6 SHELL
S7 SHELL
For
2-wire system (Video, up to 2 outdoor stations and 4 indoor stations; Audio, up to 1 outdoor station and 1 indoor station)
E SHELL
E2 SHELL
G9 SHELL
Indoor Stations
Choose the indoor stations you want...
H4 SHELL V12 SHELL V20 SHELL V1 SHELL V3 SHELL V13 SHELL
1+N Audio system or 5 + N Video system, up to 26 apartments , 2 out door stations Classic direct call system
C - 5 system (Video, up to 800 apartments , 8 outdoor stations , 9 gate stations and 9 guard units ) One cable system
05 Brief Introduction
Brief Introduction 06
Types Of Systems
2-WIRE SYSTEM
VIDEO AUDIO
5+N SYSTEM
VIDEO
1+N SYSTEM
AUDIO
5+1 2 7+4 2
7+1
202
201
7+4
Power Supply 12V
2 2
102
101
1+4
2 2
AC
TRANSFORMER
ModelPS-5E Input230V 5060Hz Output18V 800mA Notes:Used in indoor
2
+DC-
AC
TRANSFORMER
ModelPS-2E Input230V 5060Hz Output13.5V 800mA Notes:Used in indoor
+DC-
4-WIRE SYSTEM
VIDEO
5-WIRE SYSTEM
AUDIO
C-5 SYSTEM
Non-network Network
Power Supply
2
PORT4 LB VF- VF+ AF- AF+ GND DC+ PORT1
CAT-5 4 2
PORT2
LA
PORT3
CAT-5
4130S DC30-35V 90mA
LA
PORT1
PORT2
PORT3
PORT4
CAT-5
Power Supply
LA
PORT1
PORT2
PORT3
PORT4
4
Power Supply 12V
CAT-5 5 2
LB VF- VF+ AF- AF+ GND DC+ PORT2 PORT3 PORT4
2 CAT-5 CAT-5e
RJ-45 CAT-5
CAT-5e
PORT4 LB VF- VF+ AF- AF+ GND DC+
LA
PORT1
PORT2
PORT3
RJ-45 CAT-5
RJ-45
CAT-5
Power Supply 12V
CAT-5e 2 CAT-5e
Power Supply 12V
LA
PORT1
4
Power Supply 12V
CAT-5 2
PORT4 PORT3 LB VF- VF+ AF- AF+ GND DC+
Waterproof CAT-5
DC24-40V +
LA
PORT1
PORT2
RJ-45
CAT-5
000 10 1 0 13 015 !
Waterproof CAT-5 2
2 Waterproof CAT-5
CAT-5e
07 Brief Introduction
Brief Introduction 08
DC+ GND PS
CAT-5e 2
DC+ GND PS
KIT
DOOR ENTRY KIT FOR SINGLE HOUSE
09 Kit
Kit 10
FS5V12
Includes
FEATURES:
Call, talk and remote unlocking. Intercom is available between indoor stations. Double Ding-Dong ring. Power supply: Adapter, transformer for optional.
F5S50 one outdoor station Aluminum alloy panel Dimension and installation:refer to page 20S5 SHELL Surface-mounted Name plate changeable F3120-B one indoor station Dimension:20322063mm Surface-mounted B/W 4screen
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 :Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
CONNECTION DIAGRAM
2 4
Budget kit
FD5V12-N
Includes
F5D50 one outdoor station Aluminum panel Dimension and installation:refer to page 19D5 SHELL Flush-mounted Name plate changeable F3120-BN one indoor station Dimension:20322063mm Surface-mounted B/W 4screen With built-in power supply
Budget kit
FS5V20
Includes
F5S50 one outdoor station Aluminum alloy panel Dimension and installation:refer to page 20S5 SHELL Surface-mounted Name plate changeable F3200-B one indoor station Dimension:20322046mm Surface-mounted B/W 4screen
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
CONNECTION DIAGRAM
4 2
Budget kit
FD5V12
Includes
FS5V1
Includes
F5D50 one outdoor station Aluminum panel Dimension and installation:refer to page 19D5 SHELL Flush-mounted Name plate changeable F3120-B one indoor station Dimension:20322063mm Surface-mounted B/W 4screen
4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
F5S50-C one outdoor station Aluminum alloy panel Dimension and installation:refer to page 20S5 SHELL Surface-mounted Name plate changeable F3010 one indoor station Dimension:22015025mm Surface-mounted Color 5TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 :Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
11 Kit
Kit 12
FS5V11
Includes
FS7V3
Includes
F5S50-C one outdoor station Aluminum alloy panel Dimension and installation:refer to page 20S5 SHELL Surface-mounted Name plate changeable F3110 one indoor station Dimension:22020846mm Surface-mounted Color 7TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
F5S70-C one outdoor station Zinc alloy panel Dimension and installation:refer to page 20S7 SHELL Surface-mounted F3030 one indoor station Dimension:18512028mm Surface-mounted Color 3.5TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
FS7V1
Includes
FG9V1
Includes
F5S70-C one outdoor station Zinc alloy panel Dimension and installation:refer to page 20S7 SHELL Surface-mounted F3010 one indoor station Dimension:22015025mm Surface-mounted Color 5TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
F5G91-C one outdoor station Stainless steel panel With ID card reader function Dimension and installation:refer to page 20G9 SHELL Flush-mounted F3010 one indoor station Dimension:22015025mm Surface-mounted Color 5TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
FS7V11
Includes
FG9V11
Includes
F5S70-C one outdoor station Zinc alloy panel Dimension and installation:refer to page 20S7 SHELL Surface-mounted F3110 one indoor station Dimension:22020846mm Surface-mounted Color 7 TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 : Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
F5G91-C one outdoor station Stainless steel panel With ID card reader function Dimension and installation:refer to page 20G9 SHELL Flush-mounted F3110 one indoor station Dimension:22020846mm Surface-mounted Color 7TFT
Adaptor:one switch power supply AC 100-240V, DC14V, 0.8A 4013 :Transformer type switch power supply AC 100-240V, DC14V, 0.8A Packing box refer to page 18
13 Kit
Kit 14
DS4V1
Includes
7S40-C one outdoor station Dimension and installation:refer to page 21S4 SHELL Surface-mounted 7010K one master indoor station Dimension:22015025mm Surface-mounted Color 5TFT
Adaptor:one switch power supply AC 100-240V, DC24V, 1.0A Packing box refer to page 18
CONNECTION DIAGRAM(Video)
DS6V1
Includes
Australia only
DS4V13
Includes
7S60-C one outdoor station Zinc alloy panel With pin-hole color camera Dimension and installation:refer to page 19S6 SHELL Surface-mounted Name plate changeable 7010K one master indoor station Dimension:22015025mm Surface-mounted Color 5TFT 7010P Subsidiary indoor station(optional)
Adaptor:one switch power supply AC 100-240V, DC24V, 1.0A Packing box refer to page 18
7S40-C one outdoor station Dimension and installation:refer to page 21S4 SHELL Surface-mounted 7130K one master indoor station Dimension:22015027mm Surface-mounted Color 7TFT 7130P Subsidiary indoor station
Adaptor:one switch power supply AC 100-240V, DC24V, 1.0A Packing box refer to page 18
DS6V13
Includes
CONNECTION DIAGRAM(Audio)
Adaptor:one switch power supply AC 100-240V,DC24V, 1.0A Packing box refer to page 18
2 2 2
7S60-C one outdoor station Zinc alloy panel With pin-hole color camera Dimension and installation:refer to page 19S6 SHELL Surface-mounted Name plate changeable 7130K one master indoor station Dimension:22015027mm Surface-mounted Color 7TFT 7130P Subsidiary indoor station(optional)
15 Kit
Kit 16
DS2H4
Includes
Mute switch button
PACKING BOX
D5S20H one outdoor station Aluminum alloy panel Dimension and installation:refer to page21 S2 SHELL Surface-mounted Name plate changeable D3H40 one indoor station Dimension:2028067mm Surface-mounted With mute function
Adaptor:one power supply DC 14V 0.2A Packing box refer to page 18 01A-box FD5V12 01B-box FS5V12
284mm 462mm 414mm
FS5V20 FD5V12-N
88mm
88mm
01A-box
Dimension: 462(L)88(W)284(H)mm
01B-box
Dimension: 414(L)88(W)262(H)mm
02C-box DS6V1
388mm
352mm
352mm
CONNECTION DIAGRAM
2 5 2
DS4V1 DS4V13
110mm
88mm
WL-06Dd2D
Includes
AUDIO HANDSET DOOR ENTRY KIT 03A-box Adaptor:one power supply DC 15V 0.8A Packing box refer to page 18 DS2H4 04A-box WL-06Dd2D
02A-box
Dimension: 388(L)110(W)352(H)mm
02B-box
Dimension: 352(L)88(W)241(H)mm
316mm
347mm
296mm
WL-06DFaD one master indoor station Dimension:2028067mm Surface-mounted WL-06DFbD Subsidiary indoor station(optional)
88mm 70mm
02C-box
Dimension: 316(L)88(W)296(H)mm
03A-box
Dimension: 347(L)70(W)240(H)mm
358mm
75mm
04A-box
Dimension: 358(L)75(W)215(H)mm
17 Kit
215mm
240mm
WL-06Dd2 one outdoor station Aluminum panel Dimension and installation:refer to page 21D2 SHELL Flush-mounted
241mm
DS6V13
262mm
Kit 18
S5 SHELL
Unit: mm
Door/Wall Door station front Door station bracket Screw
D5 SHELL
128 92 38 42
Unit: mm
208
206
94
108
126
Iron door
201
S7 SHELL
58
Unit: mm
During installation, put the wire through the hole of PC plate, then connect it with door station terminal, and glue the PC plate on the door station rear panel at last.
48
Name plate
135
Plastic 1.Push the right edge and move to right. 2.Take off the plastic. 3.Change the name plate
60
Door/Wall Screw Door station front PC plate Door station bracket
Door/Wall Door station front Door station bracket Screw Plugs 4.Then insert the right edge into groove. 5.Push the left edge and move to left.
G9 SHELL Dimensions
150
132 64
Unit: mm
106
S6 SHELL
272 252 202
254
Unit: mm
Door/Wall Door station front Door station bracket Screw
68.5
130
Mounting
Wall Door station bracket Screw Door station front Plastic pipe Anti-dismantle screw
Name plate
Plastic
1.Insert the screw driver in the notch. Turn and push the plastic upwards. 2.Change the name plate. 3.Put the plastic back to the groove.
19 Kit
Kit 20
S4 SHELL
Unit: mm
Door/Wall Door station front Door station bracket Screw
S2 SHELL
28
Door/Wall
Panel
Frame
Unit: mm
Anti-dismantle screw
Screw
126 88
92
D2 SHELL
Unit: mm
W1
OUTDOOR STATION
DIRECT CALL PANEL AND DIGITAL PANEL
D1
L1=(L+26)
W2 W3
L3 L2=(L+24)
D2
90
Model
WL-06DD2
21 Kit
Door station 22
DIMENSION
Installation dimension
(Unit:mm)
Code
B-1 B-2 B-3 B-4
Model size
21614052 30414052 26014052 34814052
On the gate
20810838 29610838 25210838 34010838
On the wall
25012642 29412642 20612642 29412642
Item
Dimension
(refer to P24)
B-1
B-1
B-1
B-2
B-2
B-2
B-2
Features
Vandal resistant panel,stainless steel construction,waterproof,ID card,service button.
SERVICE button: In the authorized time, press SERVICE button on the outdoor station to release the door. [This button is special for postmen or other service people. The function has to be programmed by the remote control.Please refer to page 50.]
Se
References
CM-02NE26-C CM-02NE26
CM-02NE28-C CM-02NE28
Dimension
(refer to P24)
B-3
B-3
B-3
B-4
B-4
B-4
B-4 References
Item
C2313D-C
C2315D-C
C2317D-C
C2319D-C
Change name plate Remove the upper and lower end covers
When installing the door station , the upper and lower end covers shall be removed . Use a slotted screwdriver to slightly pry up from both sides , as shown in the below figure , and then the end covers will bounce out .
References
7.Finish.
Item
C2310-C
Dimension
(refer to P24)
B-4
23 Outdoor station
Outdoor station 24
Camera adjustment
DIGITAL PANEL
FEATURES:
Vandal resistant panel, stainless steel construction, waterproof, flush mounted. Compatible with all video indoor phones in C-5 system. Door can be released by various methods such as indoor phone,guard unit, ID card,password, SERVICE button and EXIT button . The IR illumination supports clear image even at night. A sound system is programmed for friendly intercommunication. The LCD window on the door panel makes the program very easy.
SERVICE
Down
Up
Left
Right
References
Item
C2608D-C 08D-C
Installation
150
Dimensions
65.5 63.0 106
132 63
Installation
500
480
430
SERVICE
68.5
130
Working parameters:
Working voltage: DC 35V Current: 50mA (DC 35V) stand by,200 mA when on Environment temperature: -20 ~ + 70
Dimensions
150
65.5 63.0
106
132
63
FEATURES
Aluminium alloy panel,water proof. Compatible with all video indoor stations in C-5 system. Door alarm function. Door can be released by various methods such as indoor Station,guard unit,ID card,password, or EXIT button. The IR illumination supports clear image even at night. The LCD window on the door panel makes the program very easy.
References
410
340
390
392
SERVICE
68.5
130
25 Outdoor station
482
Outdoor station 26
Dimensions
135 57
Unit:mm
Installation
Flush-mounted
330
Surface-mounted
As showing in the picture, move the rocker leftward or rightward to adjust the angle of camera
Step 1
Step 2
2
3
5 7 3 4 8 8
INDOOR STATION
CHOOSE HANDSET OR HANDS-FREE YOU LIKE
7
M4x28 mm screw
1 Cushion
13125 mm (bottom) 201010 mm
Rain cap
Back cover
Plug
Panel
Screw
Step 1Paste the cushion to the back cover, which can keep the outdoor station on the middle of the rain cap perfectly. Step 2 Fix therain cover on the wall by 4 screws Put the back cover inside the rain cover and fix it wiht 4 screws Put the out door panel into the back cover and fix it with 2 M428 mm screws Put the plug back to the out door station
27 Outdoor station
Indoor station 28
D SHELL FUNCTION
TECHNICAL SPECIFICATION
For 1+N system
a)Working Voltage:DC12V10% b)Current:0mA stand by,30mA when on c)Environment Temperature:-10~+55 d)Humidity :45% ~ 95%
REFERENCES
5-wire audio system WL-06DFaD Audio,Master handset WL-06DFbD Audio,Subsidiary handset 1+N system WL-02NEFD Audio handset
DIMENSION
COMPATIBILITY
Available for 5-wire audio system and 1+N system
INSTALLATION METHODS
Method 1 Method 2
202mm 144mm
60mm
80mm
67mm
29 Indoor station
Indoor station 30
H3 SHELL
H4 SHELL
COMPATIBILITY
Available for 2-wire audio system and C-5 system.
TECHNICAL SPECIFICATION
For 2-wire audio system
a)Working Voltage:DC24V b)Current:40mA stand by,100mA when on
COMPATIBILITY
Available for 2-wire audio system and C-5 system.
TECHNICAL SPECIFICATION
For 2-wire audio system
a)Working Voltage:DC14V10% b)Current:0mA stand by,15mA when on c)Environment Temperature:-10~+55
FUNCTION
FUNCTION
DIMENSION DIMENSION
84mm
36.5mm
80mm
67mm
202mm
60mm
144mm
60mm
220mm
Note: In the mute status, if the visitor calls the indoor station, it will not ring, but the light flashes,and you can still talk with the visitor or open the door for the visitor.
Surface-mounted Surface-mounted
REFERENCES
2-wire video system 7H30P C-5 system 3005 Audio,handset Audio,Subsidiary handset
Method 1 Method 2
INSTALLATION METHODS
Method 1 Method 2
31 Indoor station
Indoor station 32
V1 SHELL
FUNCTION
The system is working while it is on Available to talk while it is on System is busy while it is on
Press it to talk (available in network system only) 1.Press talk button,then press this button,you can call the guard unit. 2.Press this button directly,the guard unit will receive an alarm message. Press it to survey the entrance Press it to unlock for visitor
TECHNICATION SPECIFICATION
For 4-wire system
a)Color:5"TFT screen b)Resolution:320234 lines c)Working Voltage:DC14V10% d)Current:100mA stand by,700mA when on e)Environment Temperature:-10~+55
Brightness adjustment Contrast adjustment Talk volume adjustment Ring volume adjustment
COMPATIBILITY
Available for 4-wire system, 2-wire system,5+N system and C-5 system .
INSTALLATION METHODS
Method 1 Method 2
REFERENCES
4-Wire system F3010 Video,Color Video,Color, Master Video,Color,Subsidiary
DIMENSION
25mm
120mm
150mm
80mm
220mm
Surface-mounted
33 Indoor station
V3 SHELL
FUNCTION
The system is working while it is on Available to talk while it is on System is busy while it is on The ring volume is closed while it is on Standby button for future use Standby button for future use Press it to survey the entrance Press it to unlock for visitors Press it to talk
COMPATIBILITY
Available for 4-wire system, and C-5 system .
TECHNICAL SPECIFICATION
For 4-wire system
a)Color:3.5"TFT screen b)Resolution:160234 lines c)Working Voltage:DC14V10% d)Current:100mA stand by,700mA when on e)Environment Temperature:-10~+55
REFERENCES
4-wire system F3030 C-5 system 3031 Video,Color Video,Color
DIMENSION
INSTALLATION
61mm
185mm
28mm
Surface-mounted
a)Color:3.5"TFT screen b)Resolution:160234 lines c)Working Voltage:DC35V10% d)Current:25mA stand by,350mA when on e)Environment Temperature:-10~+55
35 Indoor station
Indoor station 36
V11 SHELL
FUNCTION
The system is working while it is on System is busy while it is on The ring volume is closedwhile it is on
Brightness adjustment Contrast adjustment Ring volume adjustment Talk volume adjustment
COMPATIBILITY
Available for 4-wire system and C-5 system .
INSTALLATION METHODS
Method 1 Method 2
TECHNICAL SPECIFICATION
For 4-wire system For C-5 system
a)Color:7"TFT screen b)Resolution:480234 lines c)Working Voltage:DC35V10% d)Current:25mA stand by,350mA when on e)Environment Temperature:-10~+55 a)Color:7"TFT screen b)Resolution:480234 lines c)Working Voltage:DC14V10% d)Current:100mA stand by,700mA when on e)Environment Temperature:-10~+55
80mm
DIMENSION
120mm
220mm
REFERENCES
4-wire system
208mm
46mm
Surface-mounted
F3110
Video,Color
Video,Color
Indoor station 38
37 Indoor station
V12 SHELL
FUNCTION
The system is working while it is on Available to talk while it is on System is busy while it is on
Standby button for future use Press it to unlock for visitors Press it to survey the entrance
TECHNICAL SPECIFICATION
For 4-wire system
Brightness adjustment Contrast adjustment Ring volume adjustment a)B/W:4"CRT screen b)Resolution:450 lines c)Working Voltage:DC14V10% d)Current:100mA stand by,700mA when on e)Environment Temperature:-10~+55
REFERENCES
4-wire system F3120-B F3120-BN 5+N system CM-02NERV12 C-5 system 3065 Video,B/W handset Video,B/W handset Video,B/W handset Video,B/W handset Built-in Power Supply
COMPATIBILITY
Available for 4-wire system,5+N system and C-5 system .
DIMENSION
INSTALLATION METHODS
61mm
105mm
203mm
63mm
Surface-mounted
a)B/W:4"CRT screen b)Resolution:450 lines c)Working Voltage:DC35V10% d)Current:10mA stand by,350mA when on e)Environment Temperature:-10~+55
39 Indoor station
Indoor station 40
V13 SHELL
FUNCTION
Spare to future use System is busy while it is on The system is working while it is on The ring volume is closed while it is on Spare to future use
Press it to unlock for visitors Press it to talk Press it to survey the entrance 1.Press it to close/open the ring 2.Press it to shield the noise outside Standby button for future use
Brightness adjustment
COMPATIBILITY
Available for 2-wire system and C-5 system .
TECHNICAL SPECIFICATION
For 2-wire system 7130K Master Indoor station
a)Color:7"TFT screen b)Resolution:480234 lines c)Working Voltage:DC24V10% d)Current:100mA stand by,500mA when on e)Environment Temperature:-10~+55
80mm
REFERENCES
2-wire system 7130K 7130P 3066 Video,Color, Master Video,Color, Subsidiary Video,Color
DIMENSION
INSTALLATION
120mm
150mm
220mm
27mm
Surface-mounted
41 Indoor station
Indoor station 42
V20 SHELL
FUNCTION
The system is working while it is on Available to talk while it is on System is busy while it is on
Press it to talk Press it to unlock for visitors Press it to survey the entrance
Talk volume adjustment Brightness adjustment Contrast adjustment Ring volume adjustment
COMPATIBILITY
Available for 4-wire system,5+N system and C-5 system .
TECHNICAL SPECIFICATION
For 4-wire system
a)B/W:4"CRT screen b)Resolution:450 lines c)Working Voltage:DC14V10% d)Current:100mA stand by,700mA when on e)Environment Temperature:-10~+55
DIMENSION
220mm
203mm
46mm
ACCESSORIES
NEEDS EXCEPT OUTDOOR STATION AND INDOOR STATION
INSTALLATION METHODS
61mm
105mm
Surface-mounted
REFERENCES Surface-mounted
4-wire system F3200-B 5+N system CM-02NERV20
43 Indoor station
Video,B/W handfree
Accessories 44
F4300
DISTRIBUTOR
Switch the audio and video signal from and to the 2 villa outdoor stations. It is applied when there are two door entrance in a same villa.
Ref.CM-02NECH-162
C4113
SWITCH
Distribute the audio and vidoe signal,it can support up to 4 indoor stations for different apartment or the same apartment according you need.
Ref.C4113
C4401
Intermediate equipment Exchange data between gateway / gate station and guard unit Up to12 ports can be connected. Auto commissioning for gateway, gate station and guard unit.
4110S/4110
Ref.C4401
Distribute the audio and vidoe signal,it can support up to 4 indoor stations under the same room number.
Ref.4110S
GATE-WAY
CM-02NEQH
Switch the audio and video signal from and to two outdoor stations. It is applied when there are two door entrance in a same building.One gate-way supports up to 12 apartments.
Ref.CM-02NEQH
It is used when the outdoor station cant meet the need of users apartment quantities.
C4301
Ref.C4301
45 Accessories
Accessories 46
POWER SUPPLY
PS-2E
Input voltage:AC 110/230V Output voltage:DC 13.5V Output current:0.8A Type:linear power supply
4008
Input voltage : AC 90V ~ 130V 50/60HZ Output voltage : DC 35V Output current : 1.4A Type : switch power supply
Ref.PS-2E Ref.4008
PS-3E
Input voltage : AC 230V 50/60HZ Output voltage : DC 12V Output current : 0.8A Type : linear power supply
Input voltage : AC 100V ~ 240V 50HZ Output voltage : DC 14V Output current : 0.8A Type : switch power supply
Ref.PS-3E Ref.4013
PS-5E
Input voltage : AC 110/230V Output voltage : DC 18V Output current : 0.8A Type:linear power supply
4014
Ref.PS-5E
Input voltage : AC 230V Output voltage : DC 24V / AC 12V Output current : 0.6A / 0.5A Type:linear power supply
4001
Ref.4014
Input voltage : AC 180 ~ 270V 50/60HZ Output voltage : DC 35V Output current : 1.4A Type : switch power supply
Ref.4001
4016
Input voltage : AC 230V Output voltage : DC 14V / AC 12V Output current : 1.5A / 1A Type:linear power supply Russia only
4003
Input voltage : AC 220 V 50HZ Output voltage : DC 15V / DC 12V Output current : 0.3A / 0.6A Type : linear power supply
4017
Ref.4003
Italy only
4007
Input voltage : AC 100V ~ 240V 50HZ Output voltage : DC 24V Output current : 0.8A Type:switch power supply Application : C-5 system
Ref.4017
Input voltage : AC 230V 50HZ Output voltage : DC 18V / AC 12V Output current : 1.5A / 1A Type:linear power supply
Ref.4007
47 Accessories
Accessories 48
GATE STATION
C6831D-C For C-5 system
Wall Installation
Unit:mm
Be fitted on the main entrance,with the intercom,door release and other functions.
Product Features Zinc alloy panel, water proof Send alarm message to guard unit when door is not closed well Different methods to enter the residential complex with gate station, e. g. throug indoor station , guard unit, ID card , password or EXIT button Camera with LED light for clear colorful picture especially at night
REMOTE CONTROL
Specifications a)Camera: Adjustable angle: 10 Visible angle: 90 Light source: White light LED b)Operating voltage: DC 35V c)Current: 90mA Stand by,260mA when on d)Temperature: -20~+70 e)Model size: 70.638.6 mm f )Resolution: 12864 lines
Ref.C6831D-C
Specifications
Key
TIME RING UNLOCK 0~9 SERVICE EXTRA
Function
Report time or program /time & date/. Choose ring type or program ring volume. Program /Unlock time/. Digits Program /SERVICE function/. Program cards together with /REG-/ and /DEL+/ buttons Delete the wrong number. Back to the top menu or out of program. Register cards or turn down the ring volume. Cancel cards or turn up the ring volume. Confirm button Function button
It is applied in G9 shell direct call outdoor stations.
Camera adjustment
Dimensions
Unit:mm
Specifications
a)Battery: DC 3V, 1.5V AAA(2pcs) b)Available distance: 3 meters c)Angle: 30
49 Accessories
Accessories 50
GUARD UNIT
C6806D-C For C-5 system
Monitor any outdoor station,two-way communication with all users, review and save the alarm records.
Product Features Intercom with indoor station, outdoor station or gate station Can monitor the outdoor station or gate station Entrance door can be opened via guard unit Can register ID cord for resident and patrol card for security guard
Specifications
Ref.C6806D-C
Appearance&Functions
SYSTEM DIAGRAM
Call button (indoor phone):pree this button, then input indoor station NO. to call. out
Unlock button: press this button to unlock the outdoor station or perimeter gate station.
51 Accessories
System Diagram 52
If you want to connect 2 outdoor stations and 4 indoor station,please refer to the diagram as follows.
Outdoor station 1
If you want to connect 1 outdoor station and 1 indoor station,please refer to the diagram as follows.
VDOOR COM AUDIO NC GND NO VIDEO
GND
Power supply
Outdoor station 1#
Outdoor station 2
DC14V
Indoor station
Video matching
Outdoor station
Indoor station
4 3 2 1
Indoor station 1# Power supply VDOOR AUDIO GND DC14V GND VIDEO
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
Power supply VDOOR COM AUDIO NC GND NO VIDEO Outdoor station VDOOR AUDIO GND VIDEO
Outdoor station 2#
Gateway
Video matching
GND DC14V
Video matching
Video matching
GND DC14V
Video matching
[Note]
Video matching
Indoor station 4#
GND DC14V
Video matching
Wiring suggestion:
Wiring distance from outdoor station to the last indoor station should be less than 100m. 1. If distance 50m, use quad cable, with the single wire resistance <4. Recommend RVV40.75 wire. 2. If distance50m, use 2-core cable and coaxial-cable, with the single wire resistance 4. Recommend RVV21.0 and SYV-75-5 wire. 1) VDOOR, AUDIO terminal use 2-core cable. 2) VIDEO, GND terminal use coaxial cable.
Indoor station 3#
Video matching
Indoor station 4#
System diagram 54
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
Outdoor station
If you want to connect 1 audio outdoor station and 1 audio indoor station,please refer to the diagram as follows.
Indoor station
Outdoor station
If you want to connect 1 video outdoor station and 1 video indoor station,please refer to the diagram as follows.
Sub. indoor station 3#
Outdoor station Master indoor phone
Type of cable
RVV20.75mm SYV-75-5-2
2
Wiring suggestion:
Distance between outdoor station and last indoor station depends on the type of the cable used. Recommend Cable and the maximum distance between outdoor station and last indoor station shows on left side.
UTP5
55 System diagram
System diagram 56
Outdoor station 1#
If you want to connect 1 outdoor station and 1 indoor station,please refer to the diagram as follows.
Black Red Yellow Green Blue
Outdoor station 2#
PS-3E
Power 12V
+ -
Electrical lock
Adaptor
Indoor station
Outdoor station
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
Black Red Yellow Green Blue Black Red Yellow Green Black Red Yellow Green Black Red Yellow Green
Power 12V + -
Electrical lock
Adaptor
Outdoor station
Video matching:
(Only for the Master indoor station)
ON
OFF
ON
OFF
The last indoor station switch should beNO,and the other Sub. indoor station switch should be OFF.
[Note] 1. An optional exit button can be fitted to the Master monitor to provide unlocking for the door. (Just for the unlocking is applied to the master indoor station lock). 2. Please wire the system as the diagram one by one.
Wiring suggestion:
Wiring between outdoor station and indoor station: Within the distance of 50 meters, use wire thicker than RVV50.5mm2 multi-copper wire. Wire cross section should be adjusted according to wire distance.
57 System diagram
System diagram 58
1(5)+N SYSTEM: The system is the direct-call structure, which is easy to install and commissioning. The surface-mounted indoor station supports communication with the outdoor station and has as remote unlock and monitor function. The outdoor station uses built-in infrared light, by which the visitor can be clearly identified even at night.
101 201
Bus
TV- TV+MONIGND
Outdoor station 1
4
A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8
402
101 201
TV- TV+MONIGND
Outdoor station 2
4
1 1 1
402
Outdoor station
Indoor station8#
Indoor station2#
Indoor station1#
TV+ MONI
DC TV
DC+
GND
VGND
MONI
V+18V VGND AGND MONI A+18V GND TV
Indoor station
T&R
VGND
GND
T&R4
1 2 3 4 5 6 7 8 1 2 3 4 5 6
T&R
Indoor station1#
Indoor station8#
Gateway
From outdoor staion to cross-section the last indoor station of conductor
TV
Bus
A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8
TV+ TVMONI POWER
T&R
1
V+18V VGND MONI GND TV
2 3
MONI
Indoor station
Video cable
2 3
Outdoor station
59 System diagram
[Note] When the hands-free indoor station is used in the system, two groups of power cords must be drawn out from the POWER and GND terminals of the outdoor station, one connecting to the audio power supply (A+18V, AGND) of the indoor phone, and the other connecting to the video power supply (V+18V, GND) of the indoor phone.
T&R
0-50M 50-100M
0.5mm2 1.0mm
2
75-3 75-5
System diagram 60
C-5 SYSTEM
Optional:
Outdoor station Indoor station
cross-section of conductor
Video cable
0-50M 50-100M
0.5mm2 1.0mm
+
2
75-3 75-5
GND
To outdoor station
DC
C-5 SYSTEM: (1)In digital call system, easily installation and commissioning. (2)Hand-up indoor station, with the function of communication with the management device and alarm and remote control unlocking. (3)Door can be released by various methods such as indoor station,guard unit,ID card,password,or EXIT button. (4)Optional indoor station number of 2 bit,3 bit and 4 bit (5)Optional ring with 4 kinds of chord. (6)One outdoor station can load 200 distributors. (7)One distributor can be connected with 4 indoor stations.
Indoor station7#
To indoor station
1 T&R 2 GND
CAT.5 CAT.5
+ DC
CAT.5E
Indoor station5#
Indoor station6#
To indoor station
Indoor station4#
VGND
Indoor station3#
CAT.5
CAT.5
VGND
TV
TV T&R
To indoor station
GND
TV 1 VGND 2 GND 4 V+18V 3
Distributor
MONI 5 T&R 6
MONI +18V
1 A+18V
CAT.5
5 V+18V 7 AGND 3 MONI 6 VGND 4 GND 2 T&R
CAT.5
TV T&R
To indoor station
8 TV
VGND
CAT.5E
Indoor station1#
Indoor station2#
Outdoor station
+ DC
Power supply
Power 12V + -
Lock
Distributor
61 System diagram
System diagram 62
Indoor station8#
CAT.5 CAT.5
Indoor station7#
Distributor
CAT.5
Indoor station8#
CAT.5
Indoor station7#
Distributor
CAT.5
CAT.5
CAT.5
CAT.5
Indoor station6#
CAT.5e CAT.5
Indoor station4#
CAT.5
Indoor station3#
Indoor station3#
Distributor
Indoor station1#
Indoor station2#
Outdoor station 1#
Accessory outdoor station Outdoor station 2# extended distributor
Power 12V
CAT.5 CAT.5e
CAT.5
+ -
Outdoor station 3#
Outdoor station 4#
Power 12V
+ -
Lock
Power 12V
+ -
Lock
Power 12V
+ -
Lock
Indoor station1#
Indoor station2#
Power supply
Gateway CAT.5e
Water proof
Outdoor station1#
Outdoor station2#
Outdoor station 6#
Outdoor station 7#
Outdoor station 8#
Power supply
Power 12V
Power 12V
Lock
Power 12V
Lock
CAT.5e Water proof
+ -
Lock
+ -
Power 12V
Lock
Power 12V
+ -
Lock
Power 12V
+ -
Lock
Power supply
Gateway
CAT.5e Waterproof
[Note] 1.The waterproof CAT.5e should be used when working in wet climate. 2.Additional power supply should be used when outdoor station 2# is more than 30 meters away from gateway.
[Note] 1.The waterproof CAT.5e should be used when working in alway wet climate. 2.Additional power supply should be used when any additional outdoor station is more than 30 meters away from extended distributor.
63 System diagram
System diagram 64
65 System diagram
Indoor station
CAT.5 CAT.5
Indoor station
Indoor station
Indoor station
CAT.5 CAT.5 CAT.5 CAT.5
Distributor
Distributor
CAT.5 CAT.5
Indoor station
CAT.5 CAT.5
Indoor station
Distributor
CAT.5
CAT.5E CAT.5E
Indoor station Indoor station Outdoor station 3 Outdoor station 4 Outdoor station 5 Outdoor station 1
Power supply
2
Lock
+ + Power 12V
Outdoor station 1
CAT.5E
Lock
+ + + + Power 12V
Outdoor station 2
Power supply
+ -
Power supply
Lock
Power 12V
Lock Lock
Power 12V
Power supply
Lock Lock
Power 12V
Power 12V + -
Lock
2 CAT.5E
Gateway
CAT.5E
Gateway Gateway
CAT.5E
CAT.5E
Indoor station
CAT.5 CAT.5
Indoor station
Distributor
CAT.5E-waterproof CAT.5E-waterproof CAT.5 CAT.5
Indoor station
Indoor station
CAT.5E
Indoor station
CAT.5 CAT.5
Switch
Distributor
CAT.5 CAT.5E CAT.5
Power supply
Power 12V
Power supply
Lock
2
+ -
Lock
Power 12V + -
Guard unit
CAT.5E-waterproof
Power supply
Lock
If you want to connect all equipments in network system,please refer to the diagram as follows.
Gateway
CAT.5E
12V Power
Electrical Lock
12V Power
Horn
Card reader Note:The working current for the electronic lock should 1A
Additional loop
1.5 mH +5V
GND
Note:The working current of the electrical lock should be 1A The output current of the power supply should be 0.8A
Working voltage:DC12~18V Working current:100mA Data transmission:RS485 interface and infrared communication Radio frequency:125KHz Iinfrard modulate frequency:38khz Induce distance:1-8cm Transmission pass:double twist shield line Reading card type:EM or Mifare card
Working voltage:DC10~13V Static current:50mA Working current:100mA Dimension:1107234mm Maximum capacity:4000 cards Card reading distance:5-10cm Applicable card:EM card or EM compatible card Frequency:125 KHz
CARD
NOTES
ECK-02N
Door-status check +5V GND NUL1 NUL2 GND DECT NO COM NC REMOTE AC DC
AC/DC NO COM DECT GND ALARM TNC NCREMOTE
Lock
Power
NOTE:unlock current should be1A GND Remote unlock control terminal
- +
TECHNICAL SPECIFICATION
Working voltage:DC/AC12~18V Working current:80mA Static current:27mA Relay current:2A Password digit:2-8 digits passwords Dimension:1107234mm