COADE Engineering Software, Inc.

Copyright @ 1994-2008
API-650/653 TANK Design/Analysis Program Message File
API-650 11th Edition, June 2007
API-653 3rd Edition, Addendum 2, Nov. 2005
Job: C:\Documents and Settings\All Users\Application Data\COADE, Inc\T
Date: 6/10/13 Time: 7:50:02 Ver 3.10
Note, this file is created by the solution module, and is an
"internal" file. All values shown in this file are presented in
the internal units (English) of the program. This file is for
data verification purposes only, this data should not be
included in any formal reports.
WIND DATA PER SECT 3.9.7.1
Wind Velocity in Miles/Hour:
Velocity Factor, (V/120)**2:
Wind Pressure, including 10% + 5 psf:
Wind Profile Area in sq.ft.:
Horizontal Wind Moment (ft-lb):
Wind Shear Force (lb):
Thickness evaluation based on Appendix A Method.
"Appendix A" Shell Course Thicknesses before
Sect 3.6.1.1 check and round up.
Course,
Course,
Course,
Course,
Course,
Course,
Course,
Course,
Course,
Course,

Design
Test
Design
Test
Design
Test
Design
Test
Design
Test

Thickness
Thickness
Thickness
Thickness
Thickness
Thickness
Thickness
Thickness
Thickness
Thickness

(in)
(in)
(in)
(in)
(in)
(in)
(in)
(in)
(in)
(in)

1
1
2
2
3
3
4
4
5
5

0.4758
0.3594
0.3380
0.2396
0.2003
0.1198
0.0625
0.0000
0.0625
0.0000

Thickness(in) for each course.


#
DESIGN
TEST
USER INPUT
1 0.47577
0.35937
0.45000
2 0.33802
0.25000
0.40000
3 0.25000
0.25000
0.35000
4 0.25000
0.25000
0.30000
5 0.25000
0.25000
0.25000
API-653 THICKNESS/CORROSION RESERVES
Retiring Thickness
Remaining Corrosion
# Design
Test
Design
Test
(in)
(in)
(in)
(in)
1
0.00000
0.00000 0.45000
0.45000
2
0.00000
0.00000 0.40000
0.40000
3
0.00000
0.00000 0.35000
0.35000
4
0.00000
0.00000 0.30000
0.30000
5
0.00000
0.00000 0.25000
0.25000

120.00
1.0000
35.958
5637.3
0.56937E+07
0.20271E+06

Allowed Fluid Heights (ft) for each course.


#
DESIGN
TEST
REQUIRED
1 25.000
32.774
25.000
2 17.000
23.574
17.000
3 11.889
17.696
9.0000
4 11.889
17.696
1.0000
5 11.889
17.696
0.00000
Annular bottom plate thickness (in) from Table 3-1 :
Annular bot. plate width (in) per API650 3.5.2
:
SHELL WEIGHTS (with Nozzles)
Computed weight of shell (lb):
0.16500E+06
Computed corroded shell weight (lb):
0.13203E+06
Insulation weight, in shell weight (lb
0.00000
Computed C.G. of shell (ft):
17.240
Weight of shell Used (lb):
0.16500E+06
C.G. of shell Used (ft):
17.240
WIND GIRDER COMPUTATIONS
Top Girder, required section modulus(in^3):
Distance from top to intermediate
wind girder (ft):
Intermediate girder section modulus (in^3):
TRANSFORMED SHELL COMPUTATIONS, Girder #:
Trnsfrmd shell height below last girder(ft)
Individual transformed course & height (ft):
Individual transformed course & height (ft):
Individual transformed course & height (ft):
Individual transformed course & height (ft):
Individual transformed course & height (ft):

42.271
17.989
19.011
1
5
4
3
2
1

29.365
8.0000
8.0000
8.0000
3.7636
1.6012

TRANSFORMED METHOD, GIRDER #


1
Dist. from top/previous to wind girder (ft) 14.682
Req section modulus of this girder (in^3):
15.516
TRANSFORMED SHELL COMPUTATIONS, Girder #:
Trnsfrmd shell height below last girder(ft)
Individual transformed course & height (ft):
Individual transformed course & height (ft):
Individual transformed course & height (ft):
Individual transformed course & height (ft):

2
4
3
2
1

14.682
1.3176
8.0000
3.7636
1.6012

THIS GIRDER IS NOT NECESSARY !!!


SEISMIC EVALUATION - FLUID WEIGHTS
Computed operating fluid weight (lb):
Computed test fluid weight (lb):
Computed empty fluid weight (lb):

0.14882E+08
0.12941E+08
0.00000

=====================================
TANK - Roof Design Data
Design Roof Load (psf):
SELF-SUPPORTING CONE ROOF

15.314

0.31250
26.476

Total weight of Roof Plates (lb):


Corroded weight of Roof Plates (lb):
3.10.5.1 required roof thickness (in):

0.14677E+06
0.14677E+06
0.50000

Computed roof weight is greater than


the input value, using computed weight!
Design Pressure, F.4.1
P (inches of Water):
P (psi)
:

40.019
1.4451

WIND OVERTURNING STABILITY CHECK


Weight for anchorage (lb):
MDL (ft-lb):
MF (ft-lb):
MPI (ft-lb):
MW (ft-lb):
wa (lb/ft):
Design tension load per bolt (lb):
Estimated Number of anchors:
Anchors needed for Section 3.11

0.16404E+06
0.84318E+07
0.21668E+08
0.00000
0.14279E+08
1305.3
10877.
36

APPENDIX F CONSIDERATIONS
Uplift Pressure Force (lb):
Resisting Weight (lb)
:
Sections F.2 through F.6 can be used.

0.00000
0.32177E+06

Maximum Design Pressure, F.4.2


Pmax (inches of Water):
Pmax (psi)
:

7.0571
0.25483

Design Pressure, F.4.1


P (inches of Water):
P (psi)
:

40.019
1.4451

Required Roof Compression Area F.5


Compression Area (in^2) from F.5.1 :
Participating Area (in^2) from 3.10.5:
Participating Area (in^2) from 3.10.6:

0.00000
7.0452
5.6362

FRANGIBLE JUNCTION LIMIT (3.10.2.5.3)


Maximum Area at Junction (in^2):

1.5080

Failure Pressure f/ Compression Ring F.6


Failure Pressure (inches of water):
62.231
Failure Pressure (psi)
:
2.2471
ANCHOR BOLT DETAILS PER API-650, 3.12
W1 (lbs) ....................
W2 (lbs) ....................
W3 (lbs) ....................
Initial Number of Anchors:
Bolt Circle Circumference:
Maximum Allowed Bolt Spacing:
Case

0.14203E+06
0.16404E+06
0.19465E+06
36.000
322.96
10.000

Uplift, Allowable, Load/Bolt

Design Pressure
0.00000
Test Pressure
0.00000
Failure Pressure
0.00000
Wind Loading
0.39156E+06
Seismic OPE
0.00000
Seismic Test
0.00000
Design Press + Wind Load
0.00000
Design Press + Seismic OPE
0.00000
Design Press + Seismic Test
0.00000

15000.
20000.
36000.
28800.
28800.
28800.
20000.
28800.
28800.

0.00000
0.00000
0.00000
10877.
0.00000
0.00000
0.00000
0.00000
0.00000

Anchor Bolt Initial Design


Case
Design Pressure
Test Pressure
Failure Pressure
Wind Loading
Seismic OPE
Seismic Test
Design Press + Wind Load
Design Press + Seismic OPE
Design Press + Seismic Test

Number, Diameter, Stress


36
0.00000
0.00000
36
0.00000
0.00000
36
0.00000
0.00000
36 1.0000
19740.
36
0.00000
0.00000
36
0.00000
0.00000
36
0.00000
0.00000
36
0.00000
0.00000
36
0.00000
0.00000

Anchor Bolt Final Design


Case
Design Pressure
Test Pressure
Failure Pressure
Wind Loading
Seismic OPE
Seismic Test
Design Press + Wind Load
Design Press + Seismic OPE
Design Press + Seismic Test

Number, Diameter,
36 1.0000
36 1.0000
36 1.0000
36 1.0000
36 1.0000
36 1.0000
36 1.0000
36 1.0000
36 1.0000

Stress
0.00000
0.00000
0.00000
19740.
0.00000
0.00000
0.00000
0.00000
0.00000