You are on page 1of 16

High Speed Cables for Enterprise Data Solutions Business Unit Telecom

The Quality Connection

Enterprise Data Solutions (EDS)

The escalating Internet data traffic has stimulated an unprecedented growth in the communication data center infrastructure. Higher bandwidth networking protocols such as Ethernet and InfiniBand are evolving rapidly to support data rates of 40/100 Gb/s and 120 Gb/s respectively. Significant changes in storage area networking (SAN) and high performance computing (HPC) are transforming the cabling technology requirements for data centers and computer rooms. The cabling interconnect technology, materials and construction, plays an increasingly larger role in the achievable interconnect distances and cable management aspects for these high speed-high density data centers, computer rooms, and equipment rooms. Network designers are struggling with critical path design choices. LEONIs EDS makes the right design choices possible.

LEONI high speed parallel pair cables with LEONIs especially formulated dielectric enables a smaller cable diameter; reducing cable density and improving air flow and heat dissipation within servers and storage enclosures. LEONIZELL dielectrics offer significantly lower loss and reduced time delay skew and amplitude skew over alternative materials. Due to their combined mechanical and electrical performance, high speed cables from LEONI are also deployed in mobile networks serving as high speed interconnections between racks inside base stations. LEONIs ParaLink cable product line is designed and offered to optimise the bandwidth cost ratio for a variety of high speed copper applications. ParaLink has established the benchmark for size, performance, and cost over current data center product offerings. Due to its almost unique value added chain, LEONI is able to offer fiber optic and data cables for EDS next to the Telecom business units ParaLink solutions. Fast Cables. Quick Solutions.

www.leoni-telecom.com

Contents

Features & Benefits 10 GHz Operations 5 GHz Operations 3 GHz Operations 3 GHz Fibre Channel 5 GHz PCI Express 10 GHz PCI Express Measuring Laboratory The Quality Connection Worldwide

4 8 9 10 11 12 13 14 15

LEONI is a member of the following organisations:

Issue 11/2008 All Para Link products are permanently enhanced for our customers. Therefore this brochure is subject to change and error. You will find the updated status in our datasheets at www.leoni-telecom.com

LEONI

ParaLink Features and Benefits


Insertion loss 15 20% improvement equals longer distance

Skew </= 100 ps/10m (3 ps/ft) elimination of insertion loss suck-outs

Insertion Loss Variation (ILV) +/ 5% controlled channel to channel loss throughout multiple channel structures

Velocity of propagation up to 84 % 20 % faster than solid PE, commonly used in the industry

Screening attenuation (EMC) up to 90 dB extremely low emission

Mode conversion excellent reduces common mode propagations

Outside diameter < 15 % increased cooling/airflow

LEONI

LEONIZELL

commonly used dielectric technology

100 %

Comparison LEONIZELL and frequent dielectric.

ParaLink diameter compared to frequently used high speed cable diameter.

Dielectric Technologies LEONIZELL unique gas injection skin-foam-skin dielectric technology has been specifically developed for the ParaLink high speed differential pair product line. The LEONIZELL structure offers a very rugged and stable mechanical structure with the following advantages and benefits compared to legacy industry structures: Maximum adhesion to the inner conductor limits pistoning effects with cable flexure minimises shrink back effects of the dielectric during termination (soldering / welding) eliminates air voids close to the center conductor prevents instable electrical performance Resilience to mechanical deformations minimises performance degradation during and after installation eliminates insertion loss suck-outs caused by bending and flexure ensures predictable performance even after severe abuse Colour coding enables an easy termination enables orientation of the conductors within the pair elimination of performance degradation due to pigmentation within dielectric technologies

Cabling Technologies The unique cabling technology used in the ParaLink manufacturing process offers significant space savings and a reduction of the outer cable diameter, in most cases up to 15 % and even as much as 20 % compared to conventional cabling technologies. The ParaLink unilay cable lay-up prevents mechanical deformation of the differential pair at the same time as reducing the effect of compression on differential pairs. Therefore it minimises negative influences on the transmission line and improves the transmission lines signal integrity. reduces the cables outer diameter (i.e. 4XAWG26 diameter is equal to that of many competitors 4XAWG28). simplifies routing and cable management. enables smaller and tighter bending radii. increases cable densities. reduces weight. reduces pistoning effects.

ParaLink reduces pistoning effects compared to frequent high speed cables.

LEONI

ParaLink Unique Performance


Insertion Loss Variation (ILV)
Insertion Loss Deviation 0 0.00 1.00 2.00 SDD21/dB Sxy21/dB 3.00 4.00 5.00 6.00 f/MHz 2000 4000 6000 8000 10000 12000 14000 16000 18000 0 10 20 30 40 50 60 0 5 10 8 110 9 1.5 10 9 210 9 2.5 10 9 3 10 9 3.5 10 9 4 10 9 4.5 10 9 5 10 9 f /MHz

Mode Conversion
Influence of mode conversion on the insertion loss Mode Conversion IL with Mode Conversion IL ideal

min.

max.

The variation of insertion loss (ILV) measures the differences of insertion loss between channels or pairs. Certain factor, for example return loss, mode conversion, impedance, dimensions of cable, insulation materials have an influence on the pair insertion loss (IL). If the IL between all pairs of a cable varies in a small range (typ. less than 5 % with ParaLink) the quality of the cable is high and the channel performance is predictable.

Mode Conversion (SCDxy) describes the relationship between transmitted differential mode signal energy at one end of the cable to the received common mode energy at the other end. It is measured in the frequency domain. The effect of mode conversion (MC) is additional insertion loss and it occurs mostly due to asymmetry between both signal wires of a pair. In time domain this effect is well known as intra pair skew, a time delay between both signal parts at 50 % of the signal step. Measuring the mode conversion of a cable has the advantage against skew measurements, that the losses of the differential signal for different data rates (= different frequency bandwidths) will be visible. Examples for Mode Conversion: Ideal cable: A symmetric differential signal is transmitted into a cable without loss. Tx+(t) = Tx-(t) At the receiving end the differential mode signal has twice the height of the signal parts Tx+ and Tx-. In this case a common mode signal does not exist.
Transmission of an ideal cable Tx+ Tx

Tx

Rx

Rx diff = Rx+ - Rx Rx comm = Rx+ + Rx

LEONI

ParaLink
0 10 20 Sxy21/dB 30 40 50 60 0 5 10 8 110 9 1.5 10 9 210 9 2.5 10 9 3 10 9 3.5 10 9 4 10 9 4.5 10 9 5 10 9 f /MHz Mode Conversion IL with Mode Conversion IL ideal

Bad Cable
0 10 20 Sxy21/dB 30 40 50 60 0 5 10 8 110 9 1.5 10 9 210 9 2.5 10 9 3 10 9 3.5 10 9 4 10 9 4.5 10 9 5 10 9 f /MHz Mode Conversion IL with Mode Conversion IL ideal

If the cable is almost absolutely symmetric, both transmitted signal parts arrive simultaneously with the same (opposite) amplitude attenuated at the receiving end of the cable. Because Rx+(t) signal is close to Rx-(t) signal, the common mode signal is still very low.

Due to different lengths of the wires within the shielded pair, the positive signal part of the differential signal arrives at the receiving end of the cable at a different time compared to the negative part. The Rx+(t) signal is not equal to -Rx-(t) any more. A common mode signal arises. At the same time the differential mode signal energy decreases.

Tx+ Tx

Tx+ Tx

Tx

Rx

Tx

Rx

Rx+ Rx

Rx+ Rx Skew

Rx diff = Rx+ - Rx Rx comm = Rx+ + Rx

Rx diff = Rx+ - Rx Rx comm = Rx+ + Rx

Jitter: The moment at which the signal changes are getting indeterminate.

Common Mode Energie

LEONI

ParaLink 11

Guarantees swept performance up to 10 GHz

Application ParaLink 11 is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 20 Gb/s per channel. Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can withstand multiple flexure over a small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

Electrical properties Impedance 100 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 100 ps/10 m (3 ps/ft) Pair to pair 400 ps/10 m (12 ps/ft) ILV max. +/ 5%
Insertion loss 0 1 2 3 a/(dB/m) 4 5 6 7 8 100 24 AWG 26 AWG 28 AWG 30 AWG 32 AWG

900 1700 2500 3300 4100 4900 5700 6500 7300 8100 8900 9700 10000 MHz

Form Factor

1X

4X

10X

12X

32 AWG 30 AWG 28 AWG 26 AWG 24 AWG

L45468-J11-C245 (PVC) L45468-J11-C246 (LSZH) L45468-J12-C245 (PVC) L45468-J12-C246 (LSZH) L45468-J13-C245 (PVC) L45468-J13-C246 (LSZH) L45468-J14-C245 (PVC) L45468-J14-C246 (LSZH) L45468-J15-C245 (PVC) L45468-J15-C246 (LSZH)

L45468-J411-C215 (PVC) L45468-J411-C216 (LSZH) L45468-J412-C215 (PVC) L45468-J412-C216 (LSZH) L45468-J413-C215 (PVC) L45468-J413-C216 (LSZH) L45468-J414-C215 (PVC) L45468-J414-C216 (LSZH) L45468-J415-C215 (PVC) L45468-J415-C216 (LSZH) L45468-J1012-C55 (PVC) L45468-J1012-C56 (LSZH) L45468-J1013-C55 (PVC) L45468-J1013-C56 (LSZH) L45468-J1014-C55 (PVC) L45468-J1014-C56 (LSZH) L45468-J1015-C55 (PVC) L45468-J1015-C56 (LSZH)

L45468-J1211-C55 (PVC) L45468-J1211-C56 (LSZH) L45468-J1212-C55 (PVC) L45468-J1212-C56 (LSZH) L45468-J1213-C55 (PVC) L45468-J1213-C56 (LSZH) L45468-J1214-C55 (PVC) L45468-J1214-C56 (LSZH) L45468-J1215-C55 (PVC) L45468-J1215-C56 (LSZH)

EA

Infini Band*

HSSG* (IEEE)

SFP+

QSFP

MG

LEONI

* InfiniBand is a registered trademark of the InfiniBand Trade Association.

*HSSG = High Speed Study Group

ParaLink 5

Guarantees swept performance up to 5 GHz

Application ParaLink 5 is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 8 Gb/s per channel. Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can withstand multiple flexure over a small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

Electrical properties Impedance 100 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 200 ps/10 m (6 ps/ft) Pair to pair 500 ps/10 m (15 ps/ft) ILV max. +/ 5 %
Insertion loss 0

1 a/(dB/m)

24 AWG 26 AWG

28 AWG 30 AWG

4 100 900 1700 2500 MHz 3300 4100 4900 5000

Form Factor

1X

4X

12X

30 AWG 28 AWG 26 AWG 24 AWG

L45468-J12-C25 (PVC) L45468-J12-C26 (LSZH) L45468-J13-C25 (PVC) L45468-J13-C26 (LSZH) L45468-J14-C75 (PVC) L45468-J14-C76 (LSZH) L45468-J15-C45 (PVC) L45468-J15-C46 (LSZH)

L45468-J412-C15 (PVC) L45468-J412-C16 (LSZH) L45468-J413-C15 (PVC) L45468-J413-C16 (LSZH) L45468-J414-C115 (PVC) L45468-J414-C116 (LSZH) L45468-J415-C25 (PVC) L45468-J415-C26 (LSZH)

L45468-J1212-C5 (PVC) L45468-J1212-C6 (LSZH) L45468-J1213-C15 (PVC) L45468-J1213-C16 (LSZH) L45468-J1214-C85 (PVC) L45468-J1214-C86 (LSZH) L45468-J1215-C25 (PVC) L45468-J1215-C26 (LSZH)

SAS2

Infini Band

HSSG (IEEE)

SFP

QSFP

MG

LEONI

ParaLink 3

Guarantees swept performance up to 3 GHz

Application ParaLink-3 is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 5 Gb/s per channel. Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can withstand multiple flexure over a small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

Electrical properties Impedance 100 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 200 ps/10 m (6 ps/ft) Pair to pair 500 ps/10 m (15 ps/ft) ILV max. +/ 5 %
Insertion loss 0

1 a/(dB/m) 24 AWG 26 AWG 2 28 AWG 30 AWG 3

4 100 900 1700 MHz 2500 3000

Form Factor

1X

4X

8X

12X

30 AWG 28 AWG 26 AWG 24 AWG

L45468-J12-C15 (PVC) L45468-J12-C16 (LSZH) L45468-J13-C45 (PVC) L45468-J13-C46 (LSZH) L45468-J14-C65 (PVC) L45468-J14-C66 (LSZH) L45468-J15-C95 (PVC) L45468-J15-C96 (LSZH)

L45468-J412-C25 (PVC) L45468-J412-C26 (LSZH) L45468-J413-C25 (PVC) L45468-J413-C26 (LSZH) L45468-J414-C35 (PVC) L45468-J414-C36 (LSZH) L45468-J415-C65 (PVC) L45468-J415-C66 (LSZH)

L45468-J812-C15 (PVC) L45468-J812-C16 (LSZH) L45468-J813-C5 (PVC) L45468-J813-C6 (LSZH) L45468-J814-C5 (PVC) L45468-J814-C6 (LSZH) L45468-J815-C5 (PVC) L45468-J815-C6 (LSZH)

L45468-J1212-C25 (PVC) L45468-J1212-C26 (LSZH) L45468-J1213-C25 (PVC) L45468-J1213-C26 (LSZH) L45468-J1214-C25 (PVC) L45468-J1214-C26 (LSZH) L45468-J1215-C15 (PVC) L45468-J1215-C16 (LSZH)

eSATA

SAS

EA

Infini Band

FCIA

SFP

HSSDCII

MG

10

LEONI

ParaLink 3 for Fibre Channel

Guarantees swept performance up to 3 GHz

Application ParaLink for Fibre Channel is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 8 Gb/s per channel at 150 Ohm. Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can bear up against extreme flexure and small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

Electrical properties Impedance 150 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 200 ps/10 m (3 ps/ft) Pair to pair 500 ps/10 m (12 ps/ft) ILV max. +/ 5 %
Insertion loss 0

1 a/(dB/m) 24 AWG 26 AWG 2 28 AWG 30 AWG 3

4 100 900 1700 MHz 2500 3000

Form Factor

1X

28 AWG 26 AWG 24 AWG 22 AWG

L45468-G12-C5 (PVC) L45468-G12-C6 (LSZH) L45468-G14-C5 (PVC) L45468-G14-C6 (LSZH) L45468-G15-C5 (PVC) L45468-G15-C6 (LSZH) L45468-G16-C5 (PVC) L45468-G16-C6 (LSZH)

FCIA

HSSDCII

MG

LEONI

11

ParaLink 5 for PCI Express with sideband signalling

Guarantees swept performance up to 5 GHz

Application ParaLink for PCI express is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 5 Gb/s per channel. Side band and clock pair (28 AWG) are available with power conductors. Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can bear up against extreme flexure and small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

Electrical properties Impedance 100 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 200 ps/10 m (3 ps/ft) Pair to pair 500 ps/10 m (12 ps/ft) ILV max. +/ 5 %
Insertion loss 0

1 a/(dB/m)

24 AWG 26 AWG

28 AWG 30 AWG

4 100 900 1700 2500 MHz 3300 4100 4900 5000

Form Factor

4X

e.g. L45468-J715-C45 & L45468-J715-C46

30 AWG 28 AWG 26 AWG 24 AWG

L45468-J712-C45 (PVC) L45468-J712-C46 (LSZH) L45468-J713-C45 (PVC) L45468-J713-C46 (LSZH) L45468-J714-C45 (PVC) L45468-J714-C46 (LSZH) L45468-J715-C45 (PVC) L45468-J715-C46 (LSZH)

GEN 2

PCI Express

IPASS

12

LEONI

IPass is a registered trademark of molex

ParaLink 11 for PCI Express with sideband signalling

Guarantees swept performance up to 10 GHz

Application ParaLink 11 for PCI express is designed for differential I/O interconnections in servers, routers, switches, storage systems and any application with theoretical data transmission speeds of up to 8 Gb/s per channel. Side band and clock pair (28 AWG) are available with power conductors.

Electrical properties Impedance 100 Ohm Insertion loss Up to 15 % lower than the industry average Skew Conductor to conductor 200 ps/10 m (3 ps/ft) Pair to pair 500 ps/10 m (12 ps/ft) ILV max. +/ 5 %
Insertion loss 0 1 2 3 a/(dB/m) 4 5 6 7 8 100 24 AWG 26 AWG 28 AWG 30 AWG

Mechancial properties Bending radius Due to the extreme durability of the special materials and the unique cable geometry the cables can bear up against extreme flexure and small bending radius. Fire performance Due to an outer jacket, which is available with halogen and lead-free propietary elastomer, the cable is certified according to UL 13 CL2 in compliance with CSA FT4 and therefore is tested according to UL 1685 and IEC 60332-3-24.

900 1700 2500 3300 4100 4900 5700 6500 7300 8100 8900 9700 10000 MHz

Form Factor

4X

e.g. L45468-J714-W215 & L45468-J714-W216

30 AWG 28 AWG 26 AWG 24 AWG

L45468-J712-W215 (PVC) L45468-J712-W216 (LSZH) L45468-J713-W215 (PVC) L45468-J713-W216 (LSZH) L45468-J714-W215 (PVC) L45468-J714-W216 (LSZH) L45468-J715-W215 (PVC) L45468-J715-W216 (LSZH)

GEN 3

PCI Express

IPASS

LEONI

13

LEONI Measuring Laboratory

Foto: Agilent Technologies

Foto: D3186 from Advantest

The measuring laboratory of the LEONI Business Unit Telecom is intended to function as a research and development lab. It will also provide quality assurance for manufacturing high-speed cables for high-bandwidth/frequency applications. A fully air-conditioned, antistatic environment and proper measurement fixture methods have been created and developed to ensure the accuracy, calibration and repeatability of testing activities. The test lab is equipped with state-of-the-art network analyzers from Agilent Technologies, enabling tests for differential transmission lines in frequencies up to 50 GHz. Two 4 port network analyzers (4x 50 Ohm or 2x 100 Ohm) equipped with the newest PLTS (Physical Layer Test System) software avoid the need for transformers, thus providing accurate measurements of the transmission line. Traditional measuring transformers must be used with an impedance matching the impedance for the transmission line, usually about 100 Ohm for InfiniBand and 150 Ohm for Fibre Channel applications. They are limited in the measurement of high frequencies and cannot measure mode conversion. This makes it virtually impossible to take accurate measurements in the bandwidth of interest for the highperformance transmission line applications mentioned above. The lab is also equipped with two Tektronix TDA for time domain measurements, such as time delay, skew, impedance and distance to fault, which can also be determined in the frequency domain using network analyzers. However, using network analyzers requires significant margins of error in mathematical transformations from frequency to time domain. The LEONI signal integrity development laboratory has extensive proprietary software at disposal to model, simulate and emulate all performance aspects of the signal integrity of a given differential transmission line, including SPICE and eField models. That, combinded with 12,5 GB/s Advantest pulse pattern generators, provides LEONI with a solid engineering base to aid and accelerate customer development programs.

14

LEONI

The Quality Connection Worldwide


LEONI quality management A consistently high level of quality is vital for our products. This means that the entire process at LEONI from a products planning to its completion is constantly monitored. Our quality management system is certified in accordance with DIN/ISO 9001:2000 and is updated permanently. Environment-friendly and safe Of course, halogen-free versions of a great number of the cables in our range are also available. This does reduce the strain in the environment, it also means less smoke and corrosive emissions in case of a fire for your safety. LEONI environmental management For us, business success with ecological responsibility is not a contradiction in terms. Because of this, environmental protection is an intrinsic element of our corporate activities. Our environment management system is certified as complying with DIN EN ISO 14001, confirming that our environment policy is effectively implemented.

LEONI LEONI

LEONI

Please find your sales contact at www.leoni-telecom.com/sales

LEONI

15

LEONI Special Cables GmbH Business Unit Telecom

Eschstrasse 1 26169 Friesoythe Germany Phone +49 (0)4491 291 5060 Fax +49 (0)4491 291 5061 E-mail telecom@leoni.com www.leoni-telecom.com

You might also like