You are on page 1of 82

PDSCHPAADJSWITCH

MO Parameter ID Parameter Name NE MML Command CellDlPcPdschPa PdschPaAdjSwitch PDSCHPAADJSWITCH eNodeB LST CELLDLPCPDSCHPA MOD CELLDLPCPDSCHPA Meaning Indicates the switch for adjusting the PA through power control on the PDSCH. If this parameter is set to ON, the PA is adjusted dynamically when the channel quality is extremely good or bad. NO NO

IsKey Mandatory

Dynamic Attribute No Feature ID Feature Name Value Type LBFD-002016 Dynamic Downlink Power Allocation Enumeration values

GUI Value Range OFF(Off), ON(On) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access OFF~0, ON~1 None OFF, ON OFF(Off) OFF(Off) CellDlPcPdschPa None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After

Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. If this switch is on, the PA is adjusted. If this switch is off, the PA is not adjusted. V100R002C00 Radio Default/Recommended

Parent topic: CellDlPcPdschPa

MimoAdaptiveSwitch
MO Parameter ID Parameter Name NE MML Command MimoAdaptiveParaCfg MimoAdaptiveSwitch MimoAdaptiveSwitch eNodeB LST MIMOADAPTIVEPARACFG MOD MIMOADAPTIVEPARACFG Meaning Indicates the switches related to adaptive MIMO. ModeCOLoopSwitch: is used to control whether adaptive switching between the open-loop mode and the closed-loop mode is applied to downlink transmission of an eNodeB that is equipped with multiple antennas. ModeDivMuxSwitch: is used to control whether adaptive switching

between the diversity mode and the multiplexing mode is applied to downlink transmission of an eNodeB that is equipped with multiple antennas. IsKey Mandatory NO NO

Dynamic Attribute No Feature ID LBFD-002017 LOFD-001003 Feature Name DL 2x2 MIMO DL 4x2 MIMO Value Type Bit field type

GUI Value Range ModeCOLoopSwitch(Open loop and Closed loop Switch), ModeDivMuxSwitch(Diversity and Multiplexing Switch) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access ModeCOLoopSwitch~0, ModeDivMuxSwitch~1 None ModeCOLoopSwitch, ModeDivMuxSwitch Open loop and Closed loop Switch:off, Diversity and Multiplexing Switch:on Open loop and Closed loop Switch:off, Diversity and Multiplexing Switch:on MimoAdaptiveParaCfg None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Not involved None

Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

The parameter modification has no impact on the equipment. The setting of this parameter determines the transmission modes that are applicable to the UEs served by a multi-antenna eNodeB and hence affects the performance such as the throughput and coverage. V100R001C01 Radio Engineering Design

Parent topic: MimoAdaptiveParaCfg

DELTAMCSENABLED
MO Parameter ID Parameter Name NE MML Command CellUlPcDedic DeltaMcsEnabled DELTAMCSENABLED eNodeB LST CELLULPCDEDIC MOD CELLULPCDEDIC Meaning Indicates whether the transmit power of the UE is adjusted according to the difference between MCSs. indication is contained in an RRC message signaled to the UE. In the message, this indication occupies one bit. The value 0, which means disabled, indicates that TF is equal to 0 because Ks is equal to 0. The value 1, which means enabled, indicates that TF is calculated on the condition that Ks is equal to 1.25.

IsKey Mandatory

NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LBFD-002026 Uplink Power Control Enumeration values

GUI Value Range UU_DISABLE(Disable), UU_ENABLE(Enable) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access UU_DISABLE~0, UU_ENABLE~1 None UU_DISABLE, UU_ENABLE UU_DISABLE(Disable) UU_DISABLE(Disable) CellUlPcDedic None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Not involved None The parameter modification has no impact on the equipment. When Ks is equal to 0, the transmit power can be adjusted according to only closed-loop TPC commands. When Ks is equal to 1.25, the transmit power can be adjusted by means of selecting different

MCSs during scheduling. This helps the UE to quickly adapt to changes in channel conditions and increases the cell throughput. Introduced in Version... Attribute V100R001C01 Radio

Default/Recommended Initial Value Setting Source Parent topic: CellUlPcDedic

ROHCSwitch
MO Parameter ID Parameter Name NE MML Command PDCPROHCPara ROHCSwitch ROHCSwitch eNodeB LST PDCPROHCPARA MOD PDCPROHCPARA Meaning Indicates whether the eNodeB supports ROHC. This switch needs to be set to ON when the eNodeB is expected to support VoIP or video services. IsKey Mandatory NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001017 RObust Header Compression (ROHC) Enumeration values

GUI Value Range OFF(Off), ON(On) Enumeration Number/Bit Unit OFF~0, ON~1 None

Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access

OFF, ON OFF(Off) OFF(Off) PDCPROHCPara None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. ROHC header compression helps reduce header overhead. The reduction is especially significant for services with small data packets, such as VoIP services. V100R001C01 Radio Engineering Design

Parent topic: PDCPROHCPara

HighestMode
MO Parameter ID PDCPROHCPara HighestMode

Parameter Name NE MML Command

HighestMode eNodeB LST PDCPROHCPARA MOD PDCPROHCPARA

Meaning

Indicates the highest mode of ROHC operation. In Unidirectional Mode (U-mode), packets are sent in one direction only (that is, from the compressor to the decompressor), and a feedback channel from the decompressor to the compressor is undesirable. Therefore, the Umode provides the lowest reliability but also the lowest feedback overhead, compared with the other two modes. In Bi-directional Optimistic Mode (O-mode), the decompressor sends the compressor the feedback, which indicates errors or context synchronization successes. Therefore, the O-mode provides higher reliability than the Umode but causes a lower amount of feedback information than the R-mode. In Bi-Directional Reliable Mode (R-mode), the reliability of context synchronization between the compressor and the decompressor is higher than that in any other mode; however, because of frequent feedback, the Rmode causes the greatest link overhead.

IsKey Mandatory

NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001017 RObust Header Compression (ROHC) Enumeration values

GUI Value Range U_MODE(Unidirectional Mode), O_MODE(Bi-directional Optimistic Mode), R_MODE(Bi-Directional Reliable Mode) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value U_MODE~1, O_MODE~2, R_MODE~3 None U_MODE, O_MODE, R_MODE U_MODE(Unidirectional Mode) U_MODE(Unidirectional Mode)

Impact Parameter Relationship Access

PDCPROHCPara None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Not involved None The parameter modification has no impact on the equipment. The reliability of packet transmission and the network link overhead are affected. V100R001C01 Radio

Engineering Design Initial Value Setting Source Parent topic: PDCPROHCPara

Profiles
MO Parameter ID Parameter Name NE MML Command PDCPROHCPara Profiles Profiles eNodeB LST PDCPROHCPARA MOD PDCPROHCPARA

Meaning

Indicates the compression profile supported by the eNodeB. Under the ROHC framework, different header compression algorithms are applicable to different protocols. Profiles define the header compression protocols (such as RTP/UDP/IP or TCP/IP), which are under the same ROHC framework, for specific types of packet streams. Each profile has a unique identifier. As defined by LTE specifications, the eNodeB supports the following profiles: profile 0x0001 (usage: RTP/UDP/IP; reference: RFC 3095 and RFC 4815), profile 0x0002 (usage: UDP/IP; reference: RFC 3095 and RFC 4815), profile 0x0003 (usage: ESP/IP; reference: RFC 3095 and RFC 4815), and profile 0x0004 (usage: IP; reference: RFC 3843 and RFC 4815).

IsKey Mandatory

NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001017 RObust Header Compression (ROHC) Bit field type

GUI Value Range Profile0x0001(Profile0x0001), Profile0x0002(Profile0x0002), Profile0x0003(Profile0x0003), Profile0x0004(Profile0x0004) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access Profile0x0001~0, Profile0x0002~1, Profile0x0003~2, Profile0x0004~3 None Profile0x0001, Profile0x0002, Profile0x0003, Profile0x0004 Profile0x0001:on, Profile0x0002:on, Profile0x0003:on, Profile0x0004:on Profile0x0001:on, Profile0x0002:on, Profile0x0003:on, Profile0x0004:on PDCPROHCPara None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification

Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Not involved None The parameter modification has no impact on the equipment. The support for different protocols is affected.

V100R001C01 Radio

Engineering Design Initial Value Setting Source Parent topic: PDCPROHCPara

DefDopplerLevel
MO Parameter ID Parameter Name NE MML Command INNERMEASSWITCH DefDopplerLevel DefDopplerLevel eNodeB MOD INNERMEASSWITCH LST INNERMEASSWITCH Meaning IsKey Mandatory Indicates the default Doppler level. When the Doppler measurement switch is shut down, parameters are set based on the default Doppler level. NO NO

Dynamic Attribute No Feature ID Feature Name LOFD-00101502 Dynamic Scheduling

Value Type

Enumeration values

GUI Value Range CLASS_0(CLASS_0), CLASS_1(CLASS_1), CLASS_2(CLASS_2) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access CLASS_0~0, CLASS_1~1, CLASS_2~2 None CLASS_0, CLASS_1, CLASS_2 CLASS_1(CLASS_1) CLASS_1(CLASS_1) INNERMEASSWITCH None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. Indicates the default Doppler level when the Doppler measurement switch is shut down. The Doppler level and other associated factors affect the CQI report mode and reported parameters, and therefore affect the feedback overhead on the uplink and throughput or coverage on the downlink. V100R001C01 Radio Default/Recommended

Parent topic: INNERMEASSWITCH

TtiBundlingSwitch
MO Parameter ID Parameter Name NE MML Command GlobalProcSwitch TtiBundlingSwitch TtiBundlingSwitch eNodeB LST GLOBALPROCSWITCH MOD GLOBALPROCSWITCH Meaning IsKey Mandatory Indicates whether TTI bundling is enabled. NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001015 Enhanced Scheduling Enumeration values

GUI Value Range OFF(Off), ON(On) Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access OFF~0, ON~1 None OFF, ON OFF(Off) OFF(Off) GlobalProcSwitch None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved

Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

Not involved None The parameter modification has no impact on the equipment. If TTI bundling is enabled for the UE, you can configure TTI bundling through the UE to obtain more transmission chances within the delay budget on the VOIP air interface, improving uplink coverage. V100R001C01 Radio Engineering Design

Parent topic: GlobalProcSwitch

PdcchBndPcSw
MO Parameter ID Parameter Name NE MML Command Meaning CellDlpcPdcch PdcchBndPcSw

PdcchBndPcSw eNodeB MOD CELLDLPCPDCCH Indicates the switch that is used to enable and disable power control applied to the PDCCH carrying dedicated control information. If this parameter is set to ON, the PDCCH power is adjusted dynamically when the channel quality is extremely good or bad. NO NO No

IsKey Mandatory Dynamic Attribute

Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

LBFD-002016 Dynamic Downlink Power Allocation Enumeration values OFF, ON OFF~0, ON~1

None OFF, ON OFF

Recommended Value OFF Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification

CellDlpcPdcch None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

None

V100R002C00

Radio Engineering Design

Parent topic: CellDlpcPdcch

Reference signal power


MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID PDSCHCfg ReferenceSignalPwr

Reference signal power eNodeB MOD PDSCHCFG Indicates the reference signal power of the cell. For details, see 3GPP TS 36.213. NO NO No LBFD-002003

LBFD-002009 LBFD-002016
Feature Name

Physical Channel Management Broadcast of system information Dynamic Downlink Power Allocation

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values -600~500 Not involved

0.1dBm -600~500 182

Recommended Value No recommended value. This parameter must be set based on the power

specification of the RRU and the cell bandwidth.


Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min)

PDSCHCfg None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

Caution Validation of Modification Impact on Radio Network Performance

None The parameter modification has no impact on the equipment.

1) Coverage: If the value of ReferenceSignalPwr is too large, crosscoverage occurs. This causes interference to other cells. If the value of ReferenceSignalPwr is too small, coverage holes appear. 2) Interference: The setting of ReferenceSignalPwr varies depending on the interference from neighboring cells. A large interference margin is required where the interference is strong. 3) Channel estimation: A larger value of ReferenceSignalPwr leads to higher channel estimation accuracy, a lower demodulation threshold, and higher receiver sensitivity, but it causes stronger interference to neighboring cells. 4) Capacity: A larger value of ReferenceSignalPwr brings better coverage, but a large value limits the power used for data transmission and hence decreases the system capacity. Set ReferenceSignalPwr appropriately to ensure a reasonable tradeoff between coverage and capacity, effective channel estimation, and appropriate interference control.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C00

Radio Default/Recommended

Parent topic: PDSCHCfg

Qam64 enabled
MO PUSCHCfg

Parameter ID Parameter Name NE MML Command Meaning

Qam64Enabled

Qam64 enabled eNodeB MOD PUSCHCFG Indicates whether 64QAM of the PUSCH is enabled. For details, see 3GPP TS 36.211.

IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

NO NO No LOFD-001006 UL 64QAM Enumeration values BOOLEAN_FALSE(False), BOOLEAN_TRUE(True) BOOLEAN_FALSE~0, BOOLEAN_TRUE~1

None BOOLEAN_FALSE, BOOLEAN_TRUE BOOLEAN_TRUE(True)

Recommended Value No recommended value. The value should be set based on the 64QAM

capability of the UE.


Impact

PUSCHCfg

Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R001C00

Radio Engineering Design

Parent topic: PUSCHCfg

UeTimerConst
This chapter describes the parameters related to the UeTimerConst MO.

Local cell identity Constant N310

Constant N311 Timer 300 Timer 301 Timer 310 Timer 311

Parent topic: Radio-tree

Intra-Frequency Mobility Load Balancing Threshold


MO Parameter ID Parameter Name NE MML Command Meaning CellMLB IntraFreqMlbThd

Intra-Frequency Mobility Load Balancing Threshold eNodeB MOD CELLMLB Indicates the threshold that is used to trigger the intra-frequency load balancing algorithm. When the cell load is equal to or lower than this threshold, the intra-frequency load balancing algorithm is triggered or stopped. This parameter is used with the load offset. That is, when the load is higher than the load threshold plus the load offset, the algorithm is triggered; when the load is lower than the load threshold, the algorithm is stopped. NO NO No LBFD-001001 LOFD-001032

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

3GPP R8 Specifications Intra-LTE Load Balancing

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values 1~100 Not involved

% 0.01~1 60

Recommended Value 60 Impact Parameter Relationship

CellMLB The difference between the intra-frequency load balancing threshold and the load offset should be greater than the DL cell dual-band intelligent shutdown threshold. The sum of the intra-frequency load balancing threshold and the load offset should be less than the DL admission load threshold. The sum of the load balancing threshold and the load offset cannot be greater than 100. Read & Write No (And no impact on the UE in idle mode)

Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of

Not involved Not involved

None The parameter modification has no impact on the equipment.

Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Parent topic: CellMLB

This parameter value has an obvious impact on the use of the MLB algorithm. A greater parameter value may cause the MLB algorithm fail to take full effect when the cell is overload. A smaller parameter value may cause too much signaling interaction and too many handovers. V100R002C00

Radio Engineering Design

SMeasure
MO Parameter ID Parameter Name NE MML Command Meaning HoMeasComm SMeasure

SMeasure eNodeB MOD HOMEASCOMM Indicates the measurement threshold. When the quality of the serving cell is higher than the threshold, the UE does not need to measure the intrafrequency, inter-frequency, and inter-RAT neighboring cells. Thus, the power consumption is reduced. NO NO

IsKey Mandatory

Dynamic Attribute Feature ID

No LBFD-00201801 LBFD-00201802 LOFD-001019 LOFD-001020 LOFD-001021 LOFD-001022 LOFD-001022

Feature Name

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between E-UTRAN and UTRAN PS Inter-RAT Mobility between E-UTRAN and GERAN PS Inter-RAT Mobility between E-UTRAN and CDMA2000 SRVCC to UTRAN SRVCC to UMTS

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values -141~-44 Not involved

dBm -141~-44 -44

Recommended Value -44 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

HoMeasComm None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R001C00

Radio Default/Recommended

Parent topic: HoMeasComm

Root sequence index


MO Parameter ID Parameter Name NE MML Command Cell RootSequenceIdx

Root sequence index eNodeB ADD CELL MOD CELL

Meaning

Indicates the logical root sequence index, which is used to derive the preamble sequence. Each logical root sequence corresponds to a physical root sequence. For the mapping between logical root sequences and physical root sequences, see 3GPP TS 36.211. NO YES No LBFD-002010 Random Access Procedure Interval values 0~837 Not involved

IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range

None 0~837

Default Value

None

Recommended Value None Impact Parameter Relationship

Cell When the preamble format is 0, 1, 2, or 3 and HighSpeedFlag is HIGH_SPEED or SUPER_HIGH_SPEED, the relations between cell radius and root sequence index are as follows: 1) If 1 m <= cell radius <= 1 km, the value range of root sequence index is 24 to 819. 2) If 1 km < cell radius <= 1.5 km, the value range of root sequence index is 30 to 815. 3) If 1.5 km < cell radius <= 2 km, the value range of root sequence index is 36 to 809. 4) If 2 km < cell radius <= 2.6 km, the value range of root sequence index is 42 to 803. 5) If 2.6 km < cell radius <= 3.5 km, the value range of root sequence index is 52 to 795. 6) If 3.5 km < cell radius <= 4.3 km, the value range of root sequence index is 64 to 789. 7) If 4.3 km < cell radius <= 5.5 km, the value range of root sequence index is 76 to 777. 8) If 5.5 km < cell radius <= 6.8 km, the value range of root sequence index is 90 to 765. 9) If 6.8 km < cell radius <= 8.6 km, the value range of root sequence index is 116 to 751. 10) If 8.6 km < cell radius <= 10.6 km, the value range of root sequence index is 136 to 729. 11) If 10.6 km < cell radius <= 13.2 km, the value range of root sequence index is 168 to 707. 12) If 13.2 km < cell radius <= 17.2 km, the value range of root sequence

index is 204 to 659. 13) If 17.2 km < cell radius <= 21.5 km, the value range of root sequence index is 264 to 629. 14) If 21.5 km < cell radius <= 27.8 km, the value range of root sequence index is 328 to 561. 15) If 27.8 km < cell radius <= 32.8 km, the value range of root sequence index is 384 to 513. Note that the cell radius cannot be larger than 32.8 km if the cell is a highspeed or super high-speed.
Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Parent topic: Cell

Read & Write Yes

Cell 0.1

None The parameter modification takes effect after the cell is automatically reset. None

V100R001C00

Radio Radio Planning

Preamble format
MO Parameter ID Parameter Name NE MML Command Cell PreambleFmt

Preamble format eNodeB ADD CELL MOD CELL

Meaning IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit

Indicates the preamble format used in the cell. For details, see 3GPP TS 36.211. NO NO No LBFD-002010 Random Access Procedure Interval values 0~4 Not involved

None

Actual Value Range Default Value

0~4 0

Recommended Value 0 Impact Parameter Relationship

Cell CellRadius <= 1,400 m: PreambleFmt for a FDD cell is set to 0 to 3, PreambleFmt for a TDD cell is set to 0 to 4; 1,400 m < CellRadius =< 14,000 m: PreambleFmt is set to 0 to 3; 1,400 m < CellRadius =< 14,000 m: PreambleFmt is set to 1 to 3; 29,000 m < CellRadius <= 77,000 m: PreambleFmt is set to 1 or 3; 77,000 m < CellRadius <= 100,000 m: PreambleFmt is set to 3.

Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version...

Read & Write Yes

Cell 0.1

None The parameter modification takes effect after the cell is automatically reset. None

V100R001C01

Attribute Initial Value Setting Source Parent topic: Cell

Radio Default/Recommended

Physical cell identity


MO Parameter ID Parameter Name NE MML Command Cell PhyCellId

Physical cell identity eNodeB ADD CELL MOD CELL

Meaning IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type

Indicates the physical cell ID. For details, see 3GPP TS 36.331. NO YES No LBFD-002009 Broadcast of system information Interval values

GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

0~503 Not involved

None 0~503 None

Recommended Value None Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in

Cell None

Read & Write Yes

Cell 0.1

None The parameter modification takes effect after the cell is automatically reset. None

V100R001C00

Version... Attribute Initial Value Setting Source Parent topic: Cell

Radio Radio Planning

Cell admin state


MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type Cell CellAdminState

Cell admin state eNodeB BLK CELL Indicates the administration state, which can be Unblock, High block, Middle block, or Low block. NO YES No None None Enumeration values

GUI Value Range

CELL_UNBLOCK(Unblock), CELL_HIGH_BLOCK(High block), CELL_MIDDLE_BLOCK(Middle block), CELL_LOW_BLOCK(Low block) CELL_UNBLOCK~0, CELL_HIGH_BLOCK~1, CELL_MIDDLE_BLOCK~2, CELL_LOW_BLOCK~3 None CELL_UNBLOCK, CELL_HIGH_BLOCK, CELL_MIDDLE_BLOCK, CELL_LOW_BLOCK None

Enumeration Number/Bit Unit Actual Value Range Default Value

Recommended Value None Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in

Cell None

Read & Write Yes

Cell Until the cell is unblock

None The parameter modification has no impact on the equipment.

None

V100R001C00

Version... Attribute Initial Value Setting Source Parent topic: Cell

Radio Engineering Design

CellAlgoSwitch
This chapter describes the parameters related to the CellAlgoSwitch MO.

AQM algorithm switch Based on Frequency Priority HO Switch BF algorithm switch CQI adjust algorithm switch DL schedule switch Downlink power control algorithm switch Dynamic adjust voltage algorithm switch Load balancing algorithm switch Local cell ID MUBF algorithm switch PUCCH algorithm switch RAC algorithm switch RACH algorithm switch RAN Sharing Mode Switch RLF detection algorithm switch SoundingRS algorithm switch Uplink power control algorithm switch Uplink schedule switch

Parent topic: Radio-tree

SINR adjust switch


MO CellUlschAlgo

Parameter ID Parameter Name NE MML Command Meaning

SinrAdjustSw

SINR adjust switch eNodeB MOD CELLULSCHALGO Indicates the switch of the SINR adjustment algorithm. This parameters indicates whether the SINR measured value is adjusted according to the ACK/NACK messages of the UL HARQ processes. NO NO No LBFD-001006 AMC Enumeration values OFF, ON OFF~0, ON~1

IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

None OFF, ON ON

Recommended Value ON Impact

CellUlschAlgo

Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R002C00

Radio Engineering Design

Parent topic: CellUlschAlgo

Semi-Persistent Scheduling Switch


MO CellUlschAlgo

Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

SpsScheSw

Semi-Persistent Scheduling Switch eNodeB MOD CELLULSCHALGO Indicates whether the semi-persistent scheduling algorithm is used during talk spurts of the VoIP service. NO NO No LOFD-001016 VoIP Semi-persistent Scheduling Enumeration values OFF, ON OFF~0, ON~1

None OFF, ON OFF

Recommended Value OFF Impact Parameter

CellUlschAlgo None

Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R002C00

Radio Engineering Design

Parent topic: CellUlschAlgo

Uplink Scheduling Strategy


MO Parameter ID CellUlschAlgo UlschStrategy

Parameter Name NE MML Command Meaning

Uplink Scheduling Strategy eNodeB MOD CELLULSCHALGO Indicates the priority of the UL user scheduling algorithm and the policy of arranging the priority of users. According to the Max C/I scheduling policy, the UE with good-quality channels are scheduled, thus the spectral efficiency is very high. The QoS of and fairness among users, however, cannot be ensured. The Max C/I scheduling policy can be used to verify the maximum capacity of the system. The fairest scheduling policy is RR. When RR is used, the system capacity, however, is the smallest. Therefore, RR is used only to verify the upper limit of the scheduling fairness in the system. In application effects, the PF scheduling policy is between the previous two policies. Thus, PF can be used to verify the capacity, coverage, and fairness of the system. According to the EPF scheduling policy, the features such as user QoS, system capacity, and channel frequency selection are considered. The basic scheduling policy is used during the performance test. In commercial scenarios, you are advised to use the EPF scheduling policy. NO NO No LBFD-002025 LOFD-001015

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

Basic Scheduling Enhanced Scheduling

Value Type GUI Value Range

Enumeration values ULSCH_STRATEGY_EPF(EPF), ULSCH_STRATEGY_MAX_CI(MAX_CI), ULSCH_STRATEGY_PF(PF), ULSCH_STRATEGY_RR(RR) ULSCH_STRATEGY_EPF~0, ULSCH_STRATEGY_MAX_CI~1, ULSCH_STRATEGY_PF~2, ULSCH_STRATEGY_RR~3

Enumeration Number/Bit

Unit Actual Value Range Default Value

None ULSCH_STRATEGY_EPF, ULSCH_STRATEGY_MAX_CI, ULSCH_STRATEGY_PF, ULSCH_STRATEGY_RR ULSCH_STRATEGY_EPF(EPF)

Recommended Value ULSCH_STRATEGY_EPF(EPF) Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting

CellUlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R002C00

Radio Default/Recommended

Source Parent topic: CellUlschAlgo

Configuration of UL Hopping
MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID CellUlschAlgo UlHoppingCfg

Configuration of UL Hopping eNodeB MOD CELLULSCHALGO Indicates whether frequency hopping (FH) is enabled or disabled and the type and scheme used for FH. NO NO No LBFD-002025 LOFD-001015

Feature Name

Basic Scheduling Enhanced Scheduling

Value Type GUI Value Range

Enumeration values HOPPING_OFF(Hopping off), HOPPING_TYPE1(Hopping Type 1), HOPPING_TYPE2(Hopping Type 2), HOPPING_TYPE2_RANDOM(Hopping Type 2 Random) HOPPING_OFF~0, HOPPING_TYPE1~1, HOPPING_TYPE2~2, HOPPING_TYPE2_RANDOM~3

Enumeration

Number/Bit Unit Actual Value Range Default Value

None HOPPING_OFF, HOPPING_TYPE1, HOPPING_TYPE2, HOPPING_TYPE2_RANDOM HOPPING_OFF(Hopping off)

Recommended Value HOPPING_OFF(Hopping off) Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute

CellUlschAlgo If UlIcicFreqSwitch is set to ON, UlHoppingCfg does not take effect. In this case, the value of UlHoppingCfg is HOPPING_OFF by default. Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R002C00

Radio

Initial Value Setting Source

Default/Recommended

Parent topic: CellUlschAlgo

UpLink Virtual MIMO Switch


MO Parameter ID Parameter Name NE MML Command Meaning CellUlschAlgo UlVmimoSw

UpLink Virtual MIMO Switch eNodeB MOD CELLULSCHALGO Indicates the switch of enabling or disabling the UL virtual MIMO matching. When UlVmimoSw is set to ON, the eNodeB performs virtual MIMO matches for UEs according to the matching principles. The matched users transmit data on the same time frequency resources. Thus, the throughput and spectral efficiency of the system are increased. Before testing other basic functions of the product, you can disable the virtual MIMO matching function. When the cell has many UEs and the throughput is relatively low, you are advised to enable the virtual MIMO matching function. NO NO No LOFD-001002 UL 2x2 MU-MIMO Enumeration values

IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type

GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

OFF, ON OFF~0, ON~1

None OFF, ON OFF

Recommended Value OFF Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in

CellUlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

V100R002C00

Version... Attribute Initial Value Setting Source

Radio Engineering Design

Parent topic: CellUlschAlgo

pre-allocation algorithm switch


MO Parameter ID Parameter Name NE MML Command Meaning CellUlschAlgo PreAllocationSwitch

pre-allocation algorithm switch eNodeB MOD CELLULSCHALGO Indicates the switch of the pre-allocation algorithm. The pre-allocation algorithm allocates resources to the light uplink traffic, the E2E delay of services is reduced. When this algorithm is enabled, the probability that the UE enters the DRX mode is reduced, and the battery usage time of the UE is shortened. NO NO No LOFD-00101502 Dynamic Scheduling

IsKey Mandatory Dynamic Attribute Feature ID Feature Name

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Enumeration values OFF, ON OFF~0, ON~1

None OFF, ON ON

Recommended Value ON Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

CellUlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

None

Introduced in Version... Attribute Initial Value Setting Source

V100R002C00

Radio Engineering Design

Parent topic: CellUlschAlgo

adaptive HARQ switch


MO Parameter ID Parameter Name NE MML Command Meaning CellUlschAlgo McsAdaptHarqSw

adaptive HARQ switch eNodeB MOD CELLULSCHALGO Indicates the switch that is used to enable and disable UL adaptive HARQ. If this switch is set to OFF, UL data is retransmitted by means of nonadaptive synchronous HARQ. If this switch is set to ON, UL data is retransmitted by means of adaptive synchronous HARQ. If this switch is set to semi-ON, adaptive HARQ is triggered when a UL grant is delivered to an HARQ process that is suspended because of, for example, resource collision, activation of a measurement gap, or PDCCH congestion. Setting this parameter to ON helps reduce resource consumption by retransmission, increase the cell throughput, and prevent retransmission conflicts. This, however, increases signaling overhead and therefore consumes more PDCCH resources. NO NO No

IsKey Mandatory Dynamic Attribute

Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

LBFD-002006 UL Synchronization HARQ Enumeration values ADAPTIVE_HARQ_SW_ON(On), ADAPTIVE_HARQ_SW_OFF(Off), ADAPTIVE_HARQ_SW_SMEION(SemiOn) ADAPTIVE_HARQ_SW_ON~0, ADAPTIVE_HARQ_SW_OFF~1, ADAPTIVE_HARQ_SW_SMEION~2 None ADAPTIVE_HARQ_SW_ON, ADAPTIVE_HARQ_SW_OFF, ADAPTIVE_HARQ_SW_SMEION ADAPTIVE_HARQ_SW_SMEION(SemiOn)

Recommended Value ADAPTIVE_HARQ_SW_SMEION(SemiOn) Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification

CellUlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

None

V100R002C00

Radio Engineering Design

Parent topic: CellUlschAlgo

FREQSELSW
MO Parameter ID Parameter Name NE MML Command Meaning CellDlschAlgo FreqSelSw

FREQSELSW eNodeB MOD CELLDLSCHALGO Indicates the switch of frequency selection scheduling. Frequency selection scheduling enables UEs to transmit data on the bands with good-quality channels. NO NO No LOFD-00101502

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Dynamic Scheduling Enumeration values OFF, ON OFF~0, ON~1

None OFF, ON ON

Recommended Value ON Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network

CellDlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved No

None The parameter modification has no impact on the equipment.

None

Performance Introduced in Version... Attribute Initial Value Setting Source

V100R001C00

Radio Engineering Design

Parent topic: CellDlschAlgo

DlScheSw
MO Parameter ID Parameter Name NE MML Command Meaning CellDlschAlgo DlScheSw

DlScheSw eNodeB MOD CELLDLSCHALGO Indicates the switch of the DL scheduling policy. EPF is an enhanced PF scheduling policy considering the QoS in terms of LTE features. Others are common scheduling policies, which do not consider the QoS of users. Max C/I is the algorithm of maximum carrier-to-interference power ratio. RR is the Round Robin algorithm. PF is the Proportional Fairness algorithm. NO NO No

IsKey Mandatory Dynamic Attribute

Feature ID

LBFD-002025 LOFD-001015

Feature Name

Basic Scheduling Enhanced Scheduling

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Enumeration values DLSCH_PRI_TYPE_EPF(EPF), DLSCH_PRI_TYPE_PF(PF), DLSCH_PRI_TYPE_MAX_CI(MAX C/I), DLSCH_PRI_TYPE_RR(RR) DLSCH_PRI_TYPE_EPF~0, DLSCH_PRI_TYPE_PF~1, DLSCH_PRI_TYPE_MAX_CI~2, DLSCH_PRI_TYPE_RR~3 None DLSCH_PRI_TYPE_EPF, DLSCH_PRI_TYPE_PF, DLSCH_PRI_TYPE_MAX_CI, DLSCH_PRI_TYPE_RR DLSCH_PRI_TYPE_EPF(EPF)

Recommended Value DLSCH_PRI_TYPE_EPF(EPF) Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution

CellDlschAlgo None

Read & Write No (And no impact on the UE in idle mode)

Not involved No

None

Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source

The parameter modification has no impact on the equipment.

None

V100R001C00

Radio Engineering Design

Parent topic: CellDlschAlgo

Minimum RX level
MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute CellSel Qrxlevmin

Minimum RX level eNodeB MOD CELLSEL Indicates the minimum required RX level. This parameter is used in the formula of the cell selection criterion S. NO NO No

Feature ID

LBFD-001001 LBFD-002009 LBFD-00201803

Feature Name

3GPP R8 Specifications Broadcast of system information Cell Selection and Re-selection

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values -70~-22 Not involved

2dBm -140~-44 -64

Recommended Value -64 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min)

CellSel None

Read & Write No (For the UE in idle mode, changes in this parameter affect cell selection.) Not involved Not involved

Caution Validation of Modification Impact on Radio Network Performance

None The parameter modification has no impact on the equipment.

If this parameter of a cell is increased, it is more difficult for the cell to meet criterion S and to become a suitable cell selected by a UE. If this parameter of a cell is decreased, it is easier for the cell to meet criterion S and to become a suitable cell selected by a UE. The parameter should be properly set so that the selected cells can provide signals that meet the quality requirement of basic services. V100R001C00

Introduced in Version... Attribute Initial Value Setting Source Parent topic: CellSel

Radio Default/Recommended

MRO
This chapter describes the parameters related to the MRO MO.

MRO statistics number MRO optimization threshold MRO optimization period Pingpong ratio threshold Pingpong handover threshold

Parent topic: Radio-tree

GBR use resource low proportion

MO Parameter ID Parameter Name NE MML Command Meaning

CellRacThd GbrRbUseLowProportion

GBR use resource low proportion eNodeB MOD CELLRACTHD Indicates the allowed lowest proportion of resources (either the uplink or downlink resources) to be occupied by GBR services. After an indication of high resource usage by GBR services is reported, an indication of low usage can be reported only when the proportion of resources currently occupied by GBR services becomes lower than the value of this parameter. NO NO No LBFD-001001 LBFD-002023

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

3GPP R8 Specifications Admission Control

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range

Interval values 0~100 Not involved

% 0~1.00

Default Value

99

Recommended Value 99 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

CellRacThd GbrRbUseLowProportion should be less than or equal to GbrRbUseHighProportion. Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

A smaller value of this parameter results in a lower probability of switching from a high-usage indication to a low-usage indication about GBR services and a higher probability of GBR service admission failure. A larger value of this parameter results in a higher probability of the pingpong effect in switching between a high-usage indication and a low-usage indication about GBR services.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C01

Radio Engineering Design

Parent topic: CellRacThd

GBR use resource high proportion


MO Parameter ID Parameter Name NE MML Command Meaning CellRacThd GbrRbUseHighProportion

GBR use resource high proportion eNodeB MOD CELLRACTHD Indicates the allowed highest proportion of resources (either the uplink or downlink resources) to be occupied by GBR services. When LCEM_RAC_ALG_GBR_USAGE_SWITCH is turned on, new GBR services cannot be admitted if the proportion of PRB resources occupied by the ongoing GBR services is higher than the value of this parameter. NO NO No LBFD-001001 LBFD-002023

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

3GPP R8 Specifications Admission Control

Value Type GUI Value Range Enumeration Number/Bit

Interval values 0~100 Not involved

Unit Actual Value Range Default Value

% 0~1.00 100

Recommended Value 100 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

CellRacThd GbrRbUseHighProportion should be greater than or equal to GbrRbUseLowProportion. Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

A smaller value of this parameter results in a smaller quantity of resources to be occupied by GBR services and a lower admission success rate of GBR services, thereby causing a higher probability of resource waste. A larger value of this parameter results in a larger quantity of resources to be occupied by GBR services and a lower admission success rate in the system. When resources are insufficient, there is a higher probability of drops in non-GBR services, and thus the call drop rate increases.

Introduced in Version...

V100R001C01

Attribute Initial Value Setting Source

Radio Engineering Design

Parent topic: CellRacThd

Non-GBR max bearer number


MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID CellRacThd MaxNonGBRBearerNum

Non-GBR max bearer number eNodeB MOD CELLRACTHD Indicates the maximum bearer number of non-GBR services in the cell. NO NO No LBFD-001001 LBFD-002023

Feature Name

3GPP R8 Specifications Admission Control

Value Type GUI Value Range

Interval values 0~9000

Enumeration Number/Bit Unit Actual Value Range Default Value

Not involved

None 0~9000 3000

Recommended Value 3000 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version...

CellRacThd None

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

A smaller parameter value indicates fewer admitted non-GBR services; a greater parameter value indicates more admitted non-GBR services.

V100R001C01

Attribute Initial Value Setting Source

Radio Engineering Design

Parent topic: CellRacThd

QCI1 handover admission threshold


MO Parameter ID Parameter Name NE MML Command Meaning CellRacThd Qci1HoThd

QCI1 handover admission threshold eNodeB MOD CELLRACTHD Indicates the admission threshold for the handed-over service whose QCI is 1. This threshold is applicable in both UL and DL. If the satisfaction rate of services with QCI of 1 is higher than or equal to this threshold, the handed-over service whose QCI is 1 can be admitted. If the satisfaction rate of services with QCI of 1 is lower than this threshold, the handed-over service whose QCI is 1 cannot be admitted.

IsKey Mandatory Dynamic Attribute Feature ID

NO NO No LBFD-001001 LBFD-002023

Feature Name

3GPP R8 Specifications Admission Control

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values 10~99 Not involved

% 0.10~0.99 90

Recommended Value 90 Impact Parameter Relationship

CellRacThd 1. The sum of Qci1CongThd and CongRelOffset must be smaller than the value of Qci1HoThd. 2. The sum of Qci1HoThd and NewCopperUserOffset must be smaller than or equal to 100.

Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

If the value of this parameter is too small, the admission threshold is too low for the handed-over service whose QCI is 1. In this case, the QoS of

Performance

the existing services cannot be guaranteed. If the value of this parameter is too large, the admission threshold is too high for the handed-over service whose QCI is 1. In this case, the admission success rate is low for services with QCI of 1.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C01

Radio Engineering Design

Parent topic: CellRacThd

QCI1 congest threshold


MO Parameter ID Parameter Name NE MML Command Meaning CellRacThd Qci1CongThd

QCI1 congest threshold eNodeB MOD CELLRACTHD Indicates the congestion threshold for services whose QCI is 1. This threshold is applicable in both UL and DL. When the satisfaction rate of services with QCI of 1 in the cell becomes lower than this threshold, the services with QCI of 1 enter the congested state. When the satisfaction rate of services with QCI of 1 in the cell becomes higher than the sum of this threshold and the congestion relief offset, the services with QCI of 1 leave the congested state.

IsKey Mandatory Dynamic Attribute Feature ID

NO NO No LBFD-001001 LBFD-002024

Feature Name

3GPP R8 Specifications Congestion Control

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values 0~99 Not involved

% 0~0.99 65

Recommended Value 65 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope

CellRacThd The sum of Qci1CongThd and CongRelOffset must be smaller than the value of Qci1HoThd. Read & Write No (And no impact on the UE in idle mode)

Not involved

Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

Not involved

None The parameter modification has no impact on the equipment.

A larger value of this parameter indicates a higher probability of system congestion. If the value is large, the system resource usage and the access success rate are low. A smaller value of this parameter indicates a lower probability of generating congestion indications and thus a higher access success rate. If the value is small, an excessive number of users might be admitted, but the load control actions are not taken in time to relieve the congestion. In this case, the overall QoS satisfaction rate of the existing services decreases and the call drop rate increases.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C01

Radio Engineering Design

Parent topic: CellRacThd

Uplink RB used ratio low threshold


MO Parameter ID Parameter Name NE CellRacThd UlRbLowThd

Uplink RB used ratio low threshold eNodeB

MML Command Meaning

MOD CELLRACTHD Indicates the threshold that determines whether the UL resource block (RB) usage is low. It is applicable to UL admission decision. If the MAC layer reports that the UL RB usage is less than this threshold, you can infer that the UL RB usage is low. NO NO No LBFD-001001 LBFD-002023 LBFD-002024

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

3GPP R8 Specifications Admission Control Congestion Control

Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range Default Value

Interval values 10~100 Not involved

% 0.10~1.00 90

Recommended Value 90 Impact

CellRacThd

Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

UlRbLowThd must be less than UlRbHighThd.

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

A greater value of this parameter leads to the higher probability of generating the low usage indication of UL resources resource blocks, thus causing excessive admission. The resource allocation, however, is protected after the admission decision, and therefore this parameter does not affect the QoS satisfaction rate of the whole system. A smaller value of this parameter leads to the lower probability of generating the low usage indication of UL resources resource blocks, thus causing excessive admission. The resource allocation, however, is protected after the admission decision, and therefore this parameter is not sensitive to admission. In this case, the decision may be mistakenly made, which triggers the load control to release services, thus increasing the services drop rate.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C01

Radio Engineering Design

Parent topic: CellRacThd

Uplink RB used ratio high threshold


MO Parameter ID Parameter Name NE MML Command Meaning CellRacThd UlRbHighThd

Uplink RB used ratio high threshold eNodeB MOD CELLRACTHD Indicates the threshold that determines whether the usage of the UL resource block (RB) is high. It is applicable to UL admission decision. If the MAC layer reports that the usage of the UL RB is greater than this threshold, you can infer that the UL RB usage is high. NO NO No LBFD-001001 LBFD-002023 LBFD-002024

IsKey Mandatory Dynamic Attribute Feature ID

Feature Name

3GPP R8 Specifications Admission Control Congestion Control

Value Type GUI Value Range Enumeration

Interval values 10~100 Not involved

Number/Bit Unit Actual Value Range Default Value

% 0.10~1.00 95

Recommended Value 95 Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance

CellRacThd UlRbHighThd must be greater than UlRbLowThd.

Read & Write No (And no impact on the UE in idle mode)

Not involved Not involved

None The parameter modification has no impact on the equipment.

A greater value of this parameter leads to the lower probability of generating the high usage indication of UL resources resource blocks, thus causing excessive admission. The resource allocation, however, is protected after the admission decision, and therefore this parameter is not sensitive to admission. In addition, a greater value of this parameter may cause slow load control. A smaller value of this parameter leads to the higher probability of generating the high usage indication of UL resources resource blocks. The satisfaction rates, however, are compared for admission decision, so this

parameter is not sensitive to admission. In this case, excessive overload control may be triggered.
Introduced in Version... Attribute Initial Value Setting Source

V100R001C01

Radio Engineering Design

Parent topic: CellRacThd

Offset for service congest relieving


MO Parameter ID Parameter Name NE MML Command Meaning CellRacThd CongRelOffset Offset for service congest relieving eNodeB MOD CELLRACTHD Indicates the offset used in congestion relief for services. After the network is congested for services with a specific QCI, the congestion is relieved if the satisfaction rate of these services is higher than the sum of this offset and the congestion threshold for services with that QCI, and the congestion is retained if the satisfaction rate is lower than the sum. NO NO

IsKey Mandatory

Dynamic Attribute No Feature ID LBFD-001001 LBFD-002024 Feature Name 3GPP R8 Specifications Congestion Control

Value Type

Interval values

GUI Value Range 0~50 Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Not involved % 0~0.50 20 20 CellRacThd 1. The sum of Qci1CongThd and CongRelOffset must be smaller than the value of Qci1HoThd. The sum of Qci2CongThd and CongRelOffset must be smaller than the value of Qci2HoThd. The sum of Qci3CongThd and CongRelOffset must be smaller than the value of Qci3HoThd. The sum of Qci4CongThd and CongRelOffset must be smaller than the value of Qci4HoThd. 2. The sum of Qci2CongThd and CongRelOffset must be smaller than the value of CopperGbrCongProportion. The sum of Qci3CongThd and CongRelOffset must be smaller than the value of CopperGbrCongProportion. The sum of Qci4CongThd and CongRelOffset must be smaller than the value of CopperGbrCongProportion. Access Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Not involved None

Validation of Modification Impact on Radio Network Performance

The parameter modification has no impact on the equipment. A larger value of this parameter results in a lower probability of congestion relief. In the case of congestion, services are released as a load control action, and therefore the call drop rate is increased. A smaller value of this parameter results in a higher probability of congestion relief, but it may lead to frequent switching between overload and overload relief.

Introduced in Version... Attribute Initial Value Setting Source

V100R001C01 Radio Engineering Design

Parent topic: CellRacThd

ANR
This chapter describes the parameters related to the ANR MO.

ANR delete cell threshold ANR add cell threshold Fast ANR PCI report amount Fast ANR PCI report interval FastAnrRsrpThd Fast ANR timer Least Handover Num for Statistic Statistic cycle IntraRat Fast ANR measurement UE number IntraRat Fast ANR valid measurement min UE number IR Fast ANR measurement UE number InterRat Fast ANR valid measurement min UE number

Parent topic: Radio-tree

CIO adjustment range configuration indicator


MO Parameter ID Parameter Name NE MML Command CellMro CioAdjLimitCfgInd CIO adjustment range configuration indicator eNodeB MOD CELLMRO LST CELLMRO Meaning Indicates whether to set the upper and lower limits of the CIO adjustment range for the cell. If this parameter is set to CFG, the CIO for the cell can be changed by an amount within the range specified by the upper and lower limits. If this parameter is set to NOT_CFG, the upper and lower limits of the CIO adjustment range for the cell in intra-frequency MRO are calculated by using the following formulas: Lower limit = Off + ofs + ocs - ofn + Hys 5, Upper limit = Off + ofs + ocs - ofn + Hys -1, where Off is the offset for intra-frequency handover, ofs and ofn are the frequency-specific offsets for the serving frequency and neighboring frequency respectively, ocs is the cell-specific offset for the serving cell, and Hys is the hysteresis for intrafrequency handover. If this parameter is set to NOT_CFG, the upper and lower limits of the CIO adjustment range for the cell in inter-frequency MRO are calculated by using the following formulas: Lower limit = -24, Upper limit = thresh + 110 - ofn + hys, where thresh is the RSRP threshold for triggering a coverage-based inter-frequency handover and hys is the hysteresis for inter-frequency handover. IsKey Mandatory NO NO

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-002005 Mobility Robust Optimization(MRO) Enumeration values

GUI Value Range NOT_CFG(Not configure), CFG(Configure) Enumeration Number/Bit NOT_CFG~0, CFG~1

Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship

None NOT_CFG, CFG NOT_CFG(Not configure) None CellMro If the CioAdjLimitCfgInd parameter is set to CFG, the CioAdjLowerLimit and CioAdjUpperLimit parameters need to be set. If the CioAdjLimitCfgInd parameter is set to NOT_CFG, the CioAdjLowerLimit and CioAdjUpperLimit parameters do not need to be set.

Access

Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. None

V100R004C00 Radio Engineering Design

Parent topic: CellMro

CSFB Utran EventB1 Time To Trig

MO Parameter ID Parameter Name NE MML Command

CSFallBackHo CsfbHoUtranTimeToTrig CSFB Utran EventB1 Time To Trig eNodeB MOD CSFALLBACKHO LST CSFALLBACKHO

Meaning

Indicates the time-to-trigger for event B1 that is used in CS fallback to UTRAN. When CS fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation of whether to trigger event B1. When detecting that the signal quality in at least one UTRAN cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-totrigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers, and the number of wrong handovers, and thus helps prevent unnecessary handovers. For details, see 3GPP TS 36.331. NO NO

IsKey Mandatory

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001033 / TDLOFD-001033 CS Fall Back to UMTS / CS Fallback to UTRAN Enumeration values

GUI Value Range 0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact 0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15 ms 0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms 40ms 40ms CSFallBackHo

Parameter Relationship Access

None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. A larger value of this parameter results in a lower probability of handover to the UTRAN cell, and a smaller value results in a higher probability. V100R002C00 Radio Radio Planning

Parent topic: CSFallBackHo

CSFB UTRAN EventB1 ECN0 Trigger Threshold


MO Parameter ID Parameter Name NE MML Command CSFallBackHo CsfbHoUtranB1ThdEcn0 CSFB UTRAN EventB1 ECN0 Trigger Threshold eNodeB MOD CSFALLBACKHO LST CSFALLBACKHO

Meaning

Indicates the Ec/No threshold for event B1, which is used in CS fallback to UTRAN. When CS fallback to UTRAN is required, this parameter is set for UEs and used in the evaluation about whether to trigger event B1. This parameter indicates the Ec/No requirement for the UTRAN cells to be included in the measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the Ec/No in at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For a cell with large signal fading variance, set this parameter to a large value to prevent unnecessary handovers. For a cell with small signal fading variance, set this parameter to a small value to ensure timely handovers. For details, see 3GPP TS 36.331. NO NO

IsKey Mandatory

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001033 / TDLOFD-001033 CS Fall Back to UMTS / CS Fallback to UTRAN Interval values

GUI Value Range -48~0 Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access Not involved 0.5dB -24~0 -13 -13 CSFallBackHo None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Not involved

Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute

None The parameter modification has no impact on the equipment. A larger value of this parameter results in a lower probability of handover to UTRAN, and a smaller value results in a higher probability. V100R001C00 Radio

Radio Planning Initial Value Setting Source Parent topic: CSFallBackHo

CSFB UTRAN EventB1 RSCP Trigger Threshold


MO Parameter ID Parameter Name NE MML Command CSFallBackHo CsfbHoUtranB1ThdRscp CSFB UTRAN EventB1 RSCP Trigger Threshold eNodeB MOD CSFALLBACKHO LST CSFALLBACKHO Meaning Indicates the RSCP threshold for event B1, which is used in CS fallback to UTRAN. When CS fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation about whether to trigger event B1. This parameter indicates the RSCP requirement for the UTRAN cells to be included in the measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the RSCP in at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331. NO NO

IsKey Mandatory

Dynamic Attribute No Feature ID Feature Name Value Type LOFD-001033 / TDLOFD-001033 CS Fall Back to UMTS / CS Fallback to UTRAN Interval values

GUI Value Range -120~-25 Enumeration Number/Bit Unit Actual Value Range Default Value Recommended Value Impact Parameter Relationship Access Not involved dBm -120~-25 -106 -106 CSFallBackHo None Read & Write

No (And no impact on the UE in idle mode) Service Interrupted After Modification Interruption Scope Not involved Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version... Attribute Initial Value Setting Source Not involved None The parameter modification has no impact on the equipment. A larger value of this parameter results in a lower probability of handover to UTRAN, and a smaller value results in a higher probability. V100R002C00 Radio Radio Planning

Parent topic: CSFallBackHo

ENodeBAlgoSwitch
This chapter describes the parameters related to the ENodeBAlgoSwitch MO.

ANR algorithm switch DlIcic algorithm switch Handover Algo switch Handover Mode switch LCS switch MRO algorithm switch PCI conflict alarm switch Power save switch Redirection switch RIM switch TPE switch TRM switch UlIcic freq switch UlIcic time switch

Parent topic: Radio-tree

You might also like