Contents

Isolator & Control Switches - 56SW


1 Pole 6 Pole 10A 63A

Time Delay Switches - 56TD

8 13 14 14 15

1 Gang

16 18 21 25 27

Changeover Switches Forward/Reverse Switches


1 Pole 3 Pole 20A 32A

Socket Outlets - 56SO


3 Pin 7 Pin 10A 50A

Programmable Time Switches - 56TC


Quartz Digital

One Piece Combination Switched Socket Outlets - 56CV


3 Pin 7 Pin 10A 50A

Push Buttons - 56PB


1 Gang

RCD Protected Outlets - 56C/RCD


3 Pin 10A 20A

Sunset Switches - 56SS10


1 Gang

Appliance Inlets - 56AI


3 Pin 5 Pin 10A 50A

Contents
Straight Plugs - 56P Angled Plugs - 56PA
3 Pin 7 Pin 10A 50A

Pendant Enclosures - 56PE

30 31 32 34 36

2 Gang

37 37 38 39 44

Cord Connectors - 56CR Appliance Connectors - 56CSC


3 Pin 5 Pin 10A 50A

Flush Surrounds - 56FA


1 Gang 4 Gang

DIN Mounting Covers - 56CB


4 Pole 13 Pole

Accessories
Mounting Feet Covers Gaskets

Enclosures - 56E
1 Gang 16 Gang

DOL Motor Starters - 56MS


230V 400V

Lids - 56L
1 6 Gang Module Mounting

Technical Section
Rating Information Product Master

Get the Facts


For over 25 years 56 Series has earned a reputation for top performance in resistance to the harsh treatment of industrial environments.
Superior Impact Strength
The high-impact strength polycarbonate material used in the manufacture of the 56 Series has a proven superior impact strength. 56 Series is proven and tested to operate in extreme temperatures from -40 to 55+.

High Level of Switch Performance


It is important to be aware that there are major differences in standard specications used to specify switch motor ratings. Most of PDLs 56 Series switches carry AC23A and AC3 motor ratings to IEC60947-3 and are capable of making up to 8 times and breaking up to 10 times their rated current, which makes them suitable for DOL switching of motors. A motor kilowatt rating is also given for each switch size. Switches carrying an M rating only have to pass a few operations at the M current stated, which is to prove an equivalent to locked rotor, not motor switching.

Specially Formulated Chemical Resistance


For those environments where harsh chemicals are used such as abattoirs, dairy and food processing industries, plastic with special chemical resistant properties is required. PDLs chemically resistant orange and white 56 Series has been developed with leading plastic material suppliers and has been tried and proven, offering overall greater resistance to chemical attack than common plastic materials. These products are easily distinguished from standard 56 Series electric grey units by their industrial orange and white colours. In these harsh environments, you cannot do better than a specialist chemically resistant product anything else is not worth the risk. For ner detail of specic aggressive chemical environments, contact your local PDL representative.

MADE IN

NZ

Solvent Bonding Capability


PDLs PVC enclosures are able to be solvent bonded to standard PVC conduit ttings. Caution should always be applied when silicon sealants are being used. Only use recommended silicon sealants: Dow Corning 732; Dow Corning 1080; Dow Corning 739 Plastic Adhesive; Selleys Window and Glass Sealant. Any silicon sealant which states Not for use with some plastics denitely should not be used. If in doubt contact your PDL representative.

Greater UV Resistance
After years of service exposed to very high UV conditions, it has become accepted that PDLs 56 Series offers excellent protection against UV discolouration and degradation a higher degree of protection than comparable products.

Full Range of Matching Gear


PDLs 56 Series accessories can be matched throughout a project with switches, socket outlets and switched socket combinations, RCD outlets, a range of enclosures and blank lids, plus the associated plugs. The Series covers single and three phase accessories, 3-pin to 7-pin 10A to 20A sockets, 3-pin to 5-pin 32A to 50A sockets and 10A to 63A switches.

Proven IP66 Protection


PDLs 56 Series has been both laboratory tested and eld proven to offer a degree of weather protection to IP66 (see below). 56 Series socket outlets in particular have a patented self-locking latch feature to ensure that this degree of protection is maintained when the product is not in use a feature not found with comparable product. This means that even when a 56 Series socket outlet is hosed down with a high pressure hose in industry for example, the socket ap will remain latched, ensuring its IP66 protection is maintained.

Modules Make Assembly Simple


Based upon a standard 100 x 100mm module for all platetype accessories, PDLs 56 Series lets you build up any combination from a simple switch or socket outlet to a full 16-gang switching station, power outlet centre or custom electrical/electronic assembly using modules and one of a wide range of matching enclosures. Matching blank lids can enclose delicate switchgear or be modied to carry custom panel equipment.

LIQUIDS

6 6

Protected against heavy seas or a strong jet of water from all practical directions.

IPx6
SOLIDS
Completely protected against dust.

Quick, Easy and Safe Wiring


Products in the Series feature large capacity terminals, big, backed-off terminal screws and, wherever appropriate, factory pre-wiring.

IP6x

PDLs 56 Series ... Rated No 1!


With features designed to outperform all other protected accessories
Total IP66 sealing from conduit entry to plug cable Non-perishable synthetic gaskets Screw caps eliminate dirt Neon indicator option in switches (56SW)

DEFINING MOMENTS IN HISTORY:


1981 56 SeriesTM released to the NZ market with a range of 22 items. 1982

Clear indication of switch position

Padlock ON/OFF facility Keylock switch option available in switches (56SW) Rotary ON/OFF switch Captive plate screws Electrical rating and specification are clearly displayed Available in high impact electric grey or chemically resistant orange and white finishes Transparent flap clearly shows pin configuration 18 ratings and pin configurations to AS/NZS3123 Plug locking ring maintains IP66 protection while in use High impact resistant UV stabilised polycarbonate Socket cover snaps shut automatically and locks to provide IP66 protection Modular system for 1 to 16 gang arrangements

Won the prestigious Prince Phillip Award for Industrial Design. 1983 Major range expansion with dozens of new items introduced including the one piece combination outlets 56CVs by mid-1984 over 300 items in the range. 1984 Internationally demanded, PDL Industries in Malaysia producing for British standard markets as well as large export business produced from Christchurch, NZ. 1989 Re-rated from IP56 to IP66. 1992 Chemically resistant orange valox introduced. 1993

Chemically Resistant White 56 Series

Continually adding new product solutions: time switches, RCDs. 1999 Chemically resistant white products introduced. 2003 Single phase plugs and connectors fully redesigned to meet todays requirements along with more new items including DIN mount covers and boards. 2005 Christchurch factory relocates to new premises the production of over 700 items for the NZ market and over 400 items for international export has new headquarters. 2006 Celebrates 25 years.

This Edition
The 2006 edition of the PDL 56 Series product catalogue includes a number of new products, innovations, and improvements.

NEW CONTENTS SECTION: > Pictorial guide for fast nding.

PAGE 2 & 3

NEW PORTABLE PROTECTED OUTLETS: > Weve gone mobile for the building and trade industry.

PAGE 26

NEW SWITCHED PENDANT OUTLETS: > IP66 rated switching connector, a product with innovation,
safety, and robustness.

PAGE 30
able Avail ly Ear 2007

NEW TECHNICAL SECTION: > Explanations, tables and data on chemical resistance,
switch ratings, international protection ratings and more.

PAGE 44

NEW 56 SERIES PRODUCT MASTER: > The ultimate guide to what products match each other.

PAGE 51

As well as these highlights this catalogue presents: The new high pressure gaskets 56HPG Series The new 15A rated products: plugs, connectors, appliance inlets The new auto-switching socket outlets The new 3 and 4 gang ush surrounds 56FA Series A new accessories section detailing spare parts availability All the existing product and ratings information that makes the PDL 56 Series number 1

Switches to IP66

56SWK110RO

56SW110RW

56SW216NGY

240V Switches
PDLs comprehensive range of 240V Switches ensures that there is always a suitable switch available for every single phase application. They are available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW. OPTIONS AVAILABLE: NEON specify N after catalogue number eg: 56SW110N KEYLOCK specify K or 2K after 56SW eg: 56SWK220 Keylock versions of all PDL switches except the Forward/ Reverse, Changeover switches and KG series switches are available. Key removable in the OFF position only Specify K after the series number eg: 56SWK110. Key removable in the OFF and ON positions Specify 2K after the series number eg: 56SW2K110. Common keyed barrels and keys are available to order for all 56 Series Keylock versions Specify C after the series number eg: 56SWKC110. YELLOW COVER/RED KNOB for isolating switches Specify YELLOW after catalogue number eg: 56SW363/2 YELLOW Combinations of the above are available. Note: All products are sold less enclosure (LE) as standard.

Dimensional Drawings

94mm

94m

28mm

FEATURES: 1 and 2 pole up to 50A Cover mounted switch mechanisms Comprehensive switch ratings IP66 weather protection rating Dual padlocking points Long-life synthetic gasket

20mm

56SW110N

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Wiring Diagram Description Cable Cross Sections Solid or Stranded Switch Ratings @ AS/NZS3133 0.4pf Inductive 250V M Rating Switch Ratings @ BS3676 250V Fluorescent Min (mm2) Max (mm2) Volts Amps

56SW110 240 10 A 1 way Single Pole 0.75 6

56SW110/2 240 10 B 2 way Single Pole 0.75 6

56SW110/2I 240 10 C Intermediate Changeover 0.75 6

56SW210 240 10 D 1 way Double Pole 0.75 6

10AX M50 8AX

10AX M50 8AX

10AX M40 8AX

10AX M40 8AX

Switches to IP66

56SW2KC110NGY

56SW232RO

56SW250RO

Wiring Diagrams

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Wiring Diagrams Description Volts Amps

56SW116 56SW216 56SW120 56SW220 56SW132 56SW232 56SW150 56SW250 240 16 A 1 way Single Pole 240 16 D 1 way Double Pole 240 20 A 1 way Single Pole 240 20 D 1 way Double Pole 240 32 A 1 way Single Pole 240 32 D 1 way Double Pole 240 50 A 1 way Single Pole 240 50 D 1 way Double Pole

1
B

Switch Disconnector Cable Cross Sections Solid or Stranded Switch Ratings @ AS/NZS3133 0.4pf Induction 250V M Rating Switch Ratings @ BS3676 250V Fluorescent Switch Ratings @ IEC 60947-3 AC23A 240V AC3 240V Min (mm2) Max (mm2) 0.75 6 16AX M120 1 16 16AX M120 1 16 20AX M150 1 16 20AX M150 1 16 32AX M180 1 16 32AX M180 6 35 50AX M250 6 35 50AX M250

1 way Single Pole

2 way Single Pole

16AX

16AX

20AX

20AX

32AX

32AX

---

---

kW Amps kW Amps

2.2 15 1.5 11 no neon option

2.2 15 1.5 11

3.0 21 2.2 15 no neon option

3.0 21 2.2 15

4.0 28 3.0 21 no neon option

4.0 28 3.0 21

5.5 35 4.0 28

5.5 35 4.0 28

Intermediate 1 way Changeover Double Pole

NOTES: AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: switch off motors during running most typical industrial applications. More info: Pages 4 and 45

Switches to IP66

56SW320GY

56SW332RW

56SW363/2RW

415V Switches
All of PDLs extensive range of 415V Switches are fully motor rated to AC23A and AC3, making them suitable for switching the harshest loads likely to be found in industry. They are available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW. OPTIONS AVAILABLE: NEON specify N after catalogue number eg: 56SW310N KEYLOCK specify K or 2K or KC after 56SW eg: 56SWK332 Refer to page 8 for detail. Note: All products are sold less enclosure (LE) as standard.
Cat No Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rate Impulse Withstand Voltage Uimp (~50Hz) Rated Thermal Current Enclosed Rated Duty Description Switch Disconnector Cable Cross Section Solid or Stranded mm2 Switch Ratings @ AS/NZS3133 500V M Rating Switch Rating @ IEC60947-3 AC21A 415V AC23A 415V AC3 415V Amps kW Amps kW Amps Amps kA kAp 10 5.5 11 4.0 8.5 10 1.5 1.0 16 7.5 15 5.5 11 16 1.5 1.0 20 11 21 7.5 15 20 1.5 1.0 32 15 28 11 21 32 1.5 1.0
56SWK320

FEATURES: 3 pole up to 63A Cover mounted switch mechanisms Comprehensive switch ratings Larger rated items (50A+63A) available in 2 gang cover IP66 weather protection rating Dual padlocking points Long-life synthetic gasket

Dimensional Drawings

94mm

94mm

28mm

56SW310 Volts Volts kV Amps 415 660 2.5 10 Uninterrupted 3 Pole

56SW316 415 660 2.5 16 Uninterrupted 3 Pole

56SW320 415 660 2.5 20 Uninterrupted 3 Pole

56SW332 415 660


20mm

2.5 32 Uninterrupted 3 Pole

56SW332

94mm

Min Max

1 16 M100

1 16 M120

1 16 M150

1 16 M180

94mm

20mm

28mm

DC21A 32V Rated Short Time Withstand Current 1 second Rated Short Circuit Making Capacity

20mm

10

Switches to IP66
Dimensional Drawings
Cat No Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz)
94mm

56SW340 Volts Volts kV Amps 415 660 2.5 40 Uninterrupted 3 Pole

56SW350 415 660 2.5 50 Uninterrupted 3 Pole

56SW350/2 415 660 2.5 50 Uninterrupted 3 Pole

56SW363/2 415 660 2.5 63 Uninterrupted 3 Pole

Rate Impulse Withstand Voltage Uimp (~50Hz) Rated Thermal Current Enclosed Rated Duty Description Switch Disconnector
190mm

Cable Cross Section Solid or Stranded mm2 Switch Ratings @ AS/NZS3133 500V M Rating Switch Rating @ IEC60947-3 AC21A 415V

Min Max

6 35 M200

6 35 M250

6 35 M250

6 35 M300

Amps kW Amps kW Amps Amps kA kAp

40 18.5 35 15 28 40 1.5 2.1

50 18.5 35 15 28 50 1.5 2.1

50 18.5 35 15 28 50 1.5 2.1

63 22 45 18.5 35 63 1.5 2.1

18mm

AC23A 415V AC3 415V

28mm

DC21A 32V Rated Short Time Withstand Current 1 second Rated Short Circuit Making Capacity

20mm
56SW363/2

Auxiliary Contacts for 56SW350/2 and 56SW363/2


PDL offer two clip-on auxiliary contacts suitable for use with the 56SW350/2 and 56SW363/2. Both auxiliaries are easily clipped to the top of the switches and are suitable for control applications such as PLCs. FEATURES: Clip-on auxiliaries cover both LV and ELV applications

Wiring Diagrams

Cat No

56SW01 Volts 125 or 250

56SW15 250

1 way Triple Pole

Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Terminal Type Description Contacts Contact Type

Amps

0.1 at 125V 0.05 at 250V Screw Single Pole 1 N/O & 1 N/C Gold

15 Screw Single Pole 1 N/O & 1 N/C Nickel/Silver

NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: switch off motors during running most typical industrial applications. DC21A Switch of DC Resistive loads, including moderate overloads. More info: Pages 4 and 45

11

500V KG Switches IP66

56SW420KGRO

56SW432/2KGRW

56SW332KGGY

500V KG Switches
PDL has utilised the proven Kraus and Naimer KG Series of switches in this range of 56 Series switches. 56SW320/KG and 56SW332/KG suit 56E1 enclosures, 56SW340/KG and 56SW363/KG require a 56E2 enclosure to provide adequate wiring room. Specialist genuine 4 and 6 pole switches available. They are available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW. NOTE: KG switches are not available in NEON or KEYLOCK versions Both 56SW420KG and 56SW432KG are available to suit 56E1 and 56E2 enclosures To order specify 56SW4##/2KG for a 56E2 enclosure All products are sold less enclosure (LE) as standard

Dimensional Drawings
94mm

94mm

28mm

Cat No Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rated Thermal Current Enclosed Wiring Diagram Cable Cross Section Solid or Stranded mm2 Switch Rating @ IEC60947-3 AC21A 415V AC23A 415V AC3 415V Amps kW Amps kW Amps Amps

56SW320KG 56SW332KG 56SW340KG 56SW363KG 56SW420KG 56SW432KG 56SW620KG Volts 500 Volts 690 Amps 20 A Min 1 Max 6 500 690 32 A 1 6 500 690 40 A 1.5 16 500 690 63 A 1.5 16 500 690 20 B 1 6 500 690 32 B 1 6 500
56SW332KG

40mm

690

Wiring
20 C 1 2 x 2.5

Diagrams

20 7.5 15 5.5 11 16

32 11 21 7.5 15 25 35 430 2.2

40 15 28 11 21 32 50 500 5

63 22 45 18.5 35 80 950 5

20 11 21 5.5 11 16 35 350 2.2

32 11 21 7.5 15 25 35 430 2.2

20 7.5 14 5.5 11 16 25 140 2.2

3 Pole

DC22A 115V Max. Fuse Size Rated Short Time Withstand Current 1 Second Rated Short Circuit Making Capacity

4 Pole

Amps 35 Amps 350 kAp 2.2

6 Pole

12

Control Switches IP66


Dimensional Drawings
94mm 42mm

94mm

30mm

56SW320FR & 56SW320CO

Wiring Diagrams
A

56SW320FRRO

56SW120CORW

Single Pole Changeover Switch, Double Throw with Centre Off


B

Changeover and Forward/Reverse Switches IP66


A range of IP66 Changeover and Forward/ Reverse switches ideal for generators, auto/ manual systems, fans, doors and conveyors. Each switch comes with a sheet of adhesive labels for the end user to select the appropriate cover markings for the specic application. Cover markings possible include: I, II FWD, REV AUX, MAIN MAN, AUTO UP, DOWN FEATURES: IP66 rated Comprehensive switch ratings Grey (GY), orange (RO), and white (RW) available All products are sold less enclosure (LE) as standard

Triple Pole Changeover Switch, Double Throw with Centre Off


C

Control Switches are supplied as a standard 100 x 100 one gang module less enclosure.
Cat No Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rated Thermal Current Enclosed Description Wiring Diagram Cable Cross Section Solid or Stranded Switch Rating @ IEC60947-3 AC21A 500V Amps 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase kW kW kW kW kW kW Amps Amps Amps Amps kAp 20 2.5 2.2 0.75 20 12 25 140 5 20 7.5 5.5 1.5 20 12 25 140 5 32 15 11 5.5 32 25 35 480 5 20 7.5 5.5 1.5 20 12 25 140 5 mm2 Volts Volts Amps 56SW120CO 500 690 20 1 Pole Changeover A 2 x 2.5 56SW320CO 500 690 20 3 Pole Changeover B 2 x 2.5 56SW332CO 500 690 32 3 Pole Changeover B 2x6 56SW320FR 500 690 20 3 Pole Reversing C 2 x 2.5

NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: switch off motors during running most typical industrial applications. AC4 Squirrel-cage motors: including reversing, plugging and inching. DC21A As for AC21A but for DC loads. DC22A Switch of inductive DC loads. More info: Pages 4 and 45

AC23A 415V 240V AC3 AC4 415V 240V 415V 240V

DC21A 24V DC22A 24V Max. Fuse Size Rated Short Time Withstand Current 1 Second Rated Short Circuit Making Capacity

13

Time Switches IP66

56TCU
PDL 56 Series Time Switches feature 24 hour and 7 day timers for the automatic time switching of process control equipment, heaters, pumps and lighting in domestic, commercial and industrial situations.
Cat No Description Rated Operational Voltage Ue (~50Hz) Switching Capacity Maximum Resistive Maximum Inductive Maximum Incandescent Minimum Switching Load Accuracy Running Reserve Minimum Switching Time Programming Spaces Cable Cross Section Solid or Stranded mm2 Min Max Volts 56TC24HB 24 Hour Quartz 230 240

56TC24HBRO
These timers are supplied in a standard 1 gang 56 Series cover for use with 56 Series deep enclosures. Supplied with a padlocking clip to enable the ap to be locked closed.
56TCU 24 Hour and 7 Day Digital 230 240

56PB2GRGY

Dimensional Drawings

56TC7DB 7 Day Quartz 230 240

94mm

94mm

Amps Amps Watts mA

16 8 1350 100 2.5 Sec Per Day 150 Hours 15 Minutes 0.75 6

16 8 1350 100 2.5 Sec Per Day 150 Hours 2 Hours 0.75 6

16 2.5 1000 100 2.5 Sec Per Day 150 Hours 1 Minute 42 (21 on/21 off) 0.75 6
30mm
56TC24HB
95mm

28mm

Momentary Contact Switches


PDL 56 Series push button switches can be used for remote switching of control gear or motor starters. These switches are supplied in a standard 56 Series one gang cover for use with 56 Series enclosures.
Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Diagrams
1 C 2

95mm

56PB1/G Volts Amps 250 16

56PB1/R 250 16
1 N/O and 1 N/C Momentary Contact Push Button

56PB2G/R 250 16
2 N/O and 2 N/C Momentary Contact 2 Push Button

28mm

56PB1/R
95m

20mm

Push Button Colour Cover Markings Cable Cross Section Solid or Stranded mm2 Utilisation Category Feed Control of Contactors Electro-Magnets and Valves AC11 250V 415V Min Max

1 x Green

1 x Red

1x Green, 1 x Red Start/Stop

28mm

0.75 6

0.75 6

0.75 6

95mm

20mm

20mm

Amps Amps

4 2

4 2

4 2

56PB2G/R

14

Sunset Switches

56SS10WE

WDL10

Dimensional Drawings

95mm
SINGLE PHASE 50Hz IP 66

95mm

PDL now offers two products in this area, the traditional PDL 56 Series sunset switch rated to IP66, and the new PDL WP Series IP56 rated sunset switch with installer selectable timer. These photoelectric cell light sensors are designed to switch a load on at dusk and off at dawn. They are ideal for outdoor lighting, pool timers, water features, entry and security applications, building management, and community control applications. They have built-in time delays to reduce nuisance switching from brief exposure to lights or shadows.

The 56 Series product is either supplied with an enclosure (56SS10WE) or less enclosure (56SS10) for use with any 56 Series enclosure combination; the WP Series product comes as standard with base and accessory pack included. Set up and installation is made easy with both products. The 56 Series comes supplied with a black daylight test cover, and the WP Series has a Bicolour LED for switching identication, and a user selectable timer, with the ability to control the delay off or permanently on functions at the turn of a dial. Available grey (GY) only.

28mm

Cat No Rated Operational Voltage Ue (~50Hz) Switching Capacity Maximum Resistive Maximum Incandescent Maximum Halogen Maximum Inductive Maximum Fluorescent Switching Light Level (Lux) Timer Bicolour LED Cable Cross Sections Solid or Stranded mm2 Operating Temp IP Rating Min Max degC Volts

56SS10 240

WDL10 240

28mm
56SS10

Amps Watts Amps Amps Amps

10 2000 8 2 Factory Preset to 50 Lux n/a n/a 0.75 6 -10 to 45 IP66

10 2400 8 6 6 Factory Preset to 50 Lux With calibration dial adjustment 20 to 100 Lux 6 position: ON Dusk to Dawn, 2H, 4H, 6H, 8H Green - power Red - daylight switch/timer operating 0.75 6 -10 to 45 IP56

15

Time Delay IP66

56TD

56MO500/1 with 648TM

PDL 56 Series Time Delay allows a load to be switched for a preset time interval. Ideal for controlling lighting and heating in commercial and industrial situations. Time Delay is supplied in a standard 1 gang cover for use with any 56 Series enclosure combination.

The old PDL 56 Series preset countdown timers have been superseded by the new modular time delay device. The 648TM ts the 56 Series module mounting covers and can be installer preset to suit the application. 56TD available grey (GY) only.

Dimensional Drawings

95mm

Cat No Description Rated Operational Voltage (~50Hz) Switching Capacity Maximum Resistive Maximum Incandescent Maximum Inductive Time Selection Range Push Button Colour LED Indicator Cable Cross Section Solid or Stranded mm2 Min Max

56TD Adjustable electronic time delay for switching load for a preset time Volts 230 240

648TM* Preset Countdown Timer


95mm

230 240
28mm

Amps Watts Amps

10 2000 6 1 second to 31.5 hours Blue 0.75 6

15 seconds to 120 minutes Silver Blue 35mm

56TD

* Fits to 56MO500 module mounting covers and can be used with the 600RM relay module to obtain up to 16A resistive load.

30mm 94mm

28mm

94mm

56MO500/1 56MO500/2

16

Distribution Solution
to IP66
Weather Protected Distribution Board
IP66 Up to 13 Way (18mm accessories) Additional wiring space both top/bottom Supplied with Base (56E6 size) with dedicated conduit entries Supplied fitted with DIN rail, Earth, and Neutral (2) bars Transparent cover flap Lockable cover Based on industry proven technology and part of the modular PDL 56 Series Complies with AS/NZS3439.3

Ordering Information: Stock code: 56CB13 Available in grey as standard with orange & white available on request

NOTE: Product information page 32

Switching Connector
New IP66 Switched Pendant
The PDL 56 SeriesTM now includes a switched pendant outlet that combines: Safety: IP66 protected, with the ability to disconnect supply without unplugging and from a prominent location. Performance: 240V 10A & 15A rated options, double pole. & Functionality: Check these features: c Positive activating slide switch c New easy-use connector flap c Built-in hanging facility c Ample wiring room c Easy assembly (patent pending) for speed of installation c Optional neon indication For further information contact customer services on 0800 652 999 www.pdl.co.nz

Ordering information: Stock codes: 56SPO310 56SPO315 Available: Early 2007


in Resistant Orange (RO) Only

NOTE: Product information page 30

17

Socket Outlets IP66

56SO320RW

56SO310/2RO

56SO316/110GY

110 250V Socket Outlets


PDL 56 Series 110 250V Socket Outlets feature a transparent hinged ap which snaps shut and locks over the socket when the plug is withdrawn, forming an automatic IP66 seal. The ap is transparent so the pin conguration can be readily identied without opening. They are available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW. Note: All products are sold less enclosure (LE) as standard.
95mm

Dimensional Drawings

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Socket Pins (Including Earth ) Description Volts Amps

56SO310 250 10 3 (Flat) NZ/Aust

56SO310/2 250 10 3 (Flat) NZ/Aust Twin Socket

56SO310R 250 10 3 (2 Flat & Round Earth) NZ/Aust Round Earth

56S0310A 250 10 3 (Flat) NZ/Aust Auto Switched Double Pole

56SO315 250 15 3 (Flat) NZ/Aust

56S0315A 250 15 3 (Flat) NZ/Aust Auto Switched Double Pole

56SO320F 250 20 3 (Flat) NZ/Aust 3 Large Flat Pin

95mm

28mm

56SO310

25mm 95mm

Socket Conguration
refer Pg 51

A Min Max 0.75 10 IP66

A 0.75 10 IP66

B 0.75 10 IP66

A 0.75 10 IP66

D 0.75 10 IP66

D 0.75 10 IP66

E 0.75 10 IP66 190mm

Cable Cross Sections Solid or Stranded mm2 IP Rating

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Socket Pins (Including Earth ) Description Socket Conguration
refer Pg 51

56SO313 Volts Amps 250 13 3 (Square) BS Square Pin Outlet C Min Max 0.75 10 IP66

56SO316/110 110 Yellow 16 3 (Round) CEE17 - 4h

56SO316/240 230 Blue 16 3 (Round) CEE17 - 6h

56SO320 250 20 3 (Round) AS/NZS3123

56SO332 250 32 3 (Round) AS/NZS3123

28mm

V 0.75 6 IP66 No Plug IP44 with Plug

W 0.75 6 IP66 No Plug IP44 with Plug

F 1.0 10 IP66

G 1.0 16 IP66
56SO310/2

Cable Cross Sections Solid or Stranded mm2 IP Rating

25mm

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

18

500V Socket Outlets IP66

56SO416KRO

56SO420RW

56SO716RW

Dimensional Drawings

Socket units are supplied as a standard 100 x 100 one gang module for use with 56E1 enclosures or combining with other accessories in a larger enclosure. They are available in high impact grey and chemically
Cat No 56SO416 Volts Amps 500 16 4 H Min Max 1 10 IP66 56SO416K* 500 16 4 I 1 10 IP66

resistant orange and white as standard. Specify GY, RO or RW. Note: All products are sold less enclosure (LE) as standard.
56SO420 500 20 4 J 1 10 IP66 56SO432 500 32 4 K 1 16 IP66 56SO440 500 40 4 L 1 16 IP66 56SO450 500 50 4 M 4 25 IP66

94mm

Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed


94mm

Number of Socket Pins (Including Earth ) Socket Conguration


28mm
refer Pg 51

Cable Cross Section Solid or Stranded mm2 IP Rating

* Special keyway for high cycle applications


30mm
56SO416

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Socket Pins (Including Earth ) Socket Conguration
refer Pg 51

56SO516 Volts Amps 500 16 5 N Min Max 1 10 IP66

56SO520 500 20 5 O 1 10 IP66

56SO532 500 32 5 P 1 16 IP66

56SO540 500 40 5 Q 1 16 IP66

56SO550 500 50 5 R 4 25 IP66

56SO616 500 16 6 S 1 10 IP66

56SO716 500 16 7 T 1 10 IP66

56SO720 500 20 7 U 1 10 IP66

Cable Cross Section Solid or Stranded mm2 IP Rating

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

19

CEE17 Socket Outlets IP57

56SO432 CEE

56SO432C CEE

CEE17 Socket Outlets


Where socket outlets to the European CEE17 standard are required, the 56 Series CEE sockets are available and suit standard 56 Series enclosures. Where a 56 Series CEE socket requires a 56 Series switch, they should be tted to a horizontally mounted 56E2 enclosure. They are available in grey (GY) only. Note: All products are sold less enclosure (LE) as standard.

Dimensional Drawings

94mm

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Socket Pins (Including Earth ) Socket Conguration
refer Pg 51

56SO316 CEE Volts Amps 230 16 3 W 6H Blue Min Max 1.5 4 IP57 BALS21238

56SO332 CEE 230 32 3 X 6H Blue 2.5 10 IP57 BALS21240

56SO416 CEE 400 16 4 Y 6H Red 1.5 4 IP57 BALS21349

56SO432 CEE 400 32 4 Z 6H Red 2.5 10 IP57 BALS21351

56SO432C CEE* 400 32 4 Aa 3H Red 2.5 10 IP57 BALS21485

56SO516 CEE 400 16 5 Bb 6H Red 1.4 4 IP57 BALS21239

56SO532 CEE
94mm

400 32
66mm

5 Cc 6H Red 2.5 10 IP57 BALS21241


30mm

Earth Pin Position Frequency Colour Cable Cross Section Solid or Stranded mm2 IP Rating Matching Plug

56SO432 CEE

* 56SO432C CEE specically for international container equipment.

20

Combination Switched Sockets IP66

56CV310RW

56CV313RO

56CV315GY

Dimensional Drawings
95mm

250V Combination Switched Sockets


The 56 SeriesTM includes an extensive range of one piece combination Switched Sockets. For keylocking and neon products, please use 56 Series switches. They are available in high impact grey, and chemically resistant orange and white as standard. Specify GY, RO or RW. Note: All products are sold less enclosure (LE) as standard. FEATURES: One piece products, clean lines, minimises dirt traps Self-locking clear socket ap Long-life synthetic gaskets IP66 weather protection rating Dual padlocking points

190mm Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Description 28mm SWITCH Description Switch Rating @ AS/NZS3133 0.4 pf inductive 250V M Rating Switch Rating @ IEC60947-3 AC23A 240V kW Amps Min Max 1 way Single Pole 10AX M50 2.2 15 0.75 6 Volts Amps 56CV310 250 10 Switched NZ/Aust. Socket 56CV313 250 13 Switched British Square Pin Socket 56CV315 250 15 Switched NZ/Aust. Socket

1 way Single Pole 16AX M50 2.2 15 0.75 6

1 way Double Pole 16AX M120 2.2 15 1.0 16

Cable Cross Section Solid or Stranded mm2 25mm


56CV310

SOCKET Number of Socket Pins Including (Earth ) Socket Conguration - Refer Pg 51

3 (Flat) A Min Max 1.0 10 IP66

3 (Square) C 1.0 10 IP66

3 (Flat) D 1.0 10 IP66

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51 AC23A Switch of motor loads or other highly inductive loads. More info: Pages 4 and 45

Cable Cross Section Solid or Stranded mm2 IP Rating

21

Combination Switched Sockets IP66

56CV316/240GY

56CV332RO

250V Combination Switched Sockets


FEATURES: One piece products, clean lines, minimises dirt traps Self-locking clear socket ap Long-life synthetic gaskets IP66 weather protection rating Dual padlocking points
Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Description Volts Amps 56CV316/240 240 16 Switched CEE17-4h Socket (Blue) 56CV320 250 20 Switched AS3123 Socket 56CV332

Dimensional Drawings
95mm

190mm 250 32 Switched AS3123 Socket 28mm 1 way Double Pole 20AX M150 3.0 21 7.5 15 1.0 16 1 way Double Pole 32AX M150 4.0 28 11 21 1.0 16 25mm
56CV310

SWITCH Description Switch Rating @ AS/NZS3133 0.4 pf inductive 250V M Rating Switch Rating @ IEC60947-3 AC23A 240V AC3 240V kW Amps kW Amps Min Max

1 way Double Pole 16AX M120 2.2 15 5.5 11 1.0 16

Cable Cross Section Solid or Stranded mm2 SOCKET Number of Socket Pins Including (Earth ) Socket Conguration - Refer Pg 51 Cable Cross Section Solid or stranded mm2 IP Rating

3 (Round) W Min Max 1.0 6 IP66 without plug; IP44 with plug

3 (Round) F 1.0 10 IP66

3 (Round) G 1.0 16 IP66

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

22

Combination Switched Sockets IP66

Interlock feature (seen from rear)

56CV432RO

Dimensional Drawings

500V Combination Switched Sockets


All 500V Switched Sockets rated 32A and above have an internal interlocking feature (plugs cannot be withdrawn or inserted when the switch is in the ON position) with this feature available on 16A and 20A units on request. The 56CV 3,4 and 5 pin units of 16A and 20A rating (except CEE17 style) have a one piece, internally wired base. This results in faster and tidier installation from having more space and less terminals to check. For keylocking and neon products please use 56 Series switches.
190mm

Note: All products are sold less enclosure (LE) as standard. FEATURES: One piece products, clean lines, minimises dirt traps Self-locking clear socket ap Long-life synthetic gaskets Safety interlock feature (32A + above) 16A and 20A with one piece, internally wired, switch and socket base IP66 weather protection rating Dual padlocking points
56CV420 500 20 3 Pole 20AX M150 11.0 21 7.5 15 1 16 56CV432 500 32 3 Pole 32AX M180 15.0 28 11 21 1 16 56CV440 500 40 3 Pole 50AX M250 18.5 35 15 28 6 35 56CV450 500 50 3 Pole 50AX M250 18.5 35 15 28 6 35

94mm

Available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW.
Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Volts Amps 56CV416 500 16 3 Pole 16AX M120 kW Amps kW Amps Min Max 7.5 15 5.5 11 1 16

56CV416K 500 16 3 Pole 16AX M120 7.5 15 5.5 11 1 16

28mm

SWITCH Description Switch Rating @ AS/NZS3133 0.4 pf inductive 250V M Rating Switch Rating @ IEC60947-3 AC23A 415V AC3 415V

Cable Cross Sections Solid or Stranded mm2


30mm
56CV532

SOCKET Number of Socket Pins (Including Earth ) Socket Conguration - Refer Pg 51

4 H Min Max 1.0 10 IP66

4 I 1.0 10 IP66

4 J 1.0 10 IP66

4 K 1.0 16 IP66

4 L 1.0 16 IP66

4 M 6.0 25 IP66

NOTES: AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: switch off motors during running most typical industrial applications More info: Pages 4 and 45

Cable Cross Section Solid or stranded mm2 IP Rating

23

Combination Switched Sockets IP66


Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed SWITCH Description Switch Rating @ AS/NZS3133 0.4 pf inductive 500V M Rating Switch Rating @ IEC60947-3 AC23A 415V AC3 415V Volts Amps 56CV516 500 16 3 Pole 16AX M120 56CV520 500 20 3 Pole 20AX M150 56CV532 500 32 3 Pole 32AX M180 56CV540 500 40 3 Pole 50AX M250 56CV550 500 50 3 Pole 50AX M250 56CV616 500 16 3 Pole 16AX M120 56CV716 500 16 3 Pole 16AX M120 56CV720 500 20 3 Pole 20AX M150

kW Amps kW Amps Min Max

7.5 15 5.5 11 1 16

11.0 21 7.5 15 1 16

15.0 28 11 21 1 16

18.5 35 15 28 6 35

18.5 35 15 28 6 35

7.5 15 5.5 11 1 16

7.5 15 5.5 11 1 16

11.0 21 7.5 15 1 16

Cable Cross Sections Solid or Stranded mm2 SOCKET Number of Socket Pins (Including Earth ) Socket Conguration
refer Pg 51

Wiring Diagrams

N Min Max 1.0 10 IP66

O 1.0 10 IP66

P 1.0 16 IP66

Q 1.0 16 IP66

R 6.0 25 IP66

S 1.0 10 IP66

T 1.0 10 IP66

U 1.0 10 IP66

Cable Cross Section Solid or stranded mm2 IP Rating

NOTES: AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: switch off motors during running most typical industrial applications More info: Pages 4 and 45

24

RCD Protected Outlets IP66

56RCD20-30RO

56C310RCD-30RO

56C320RCD-30RO

Dimensional Drawings

56 Series RCD protected socket outlets protect the user against an earth fault. They feature double pole switching and respond to earth fault in pulsating DC applications. 56 Series RCDs are available with both latching and non-latching RCD modules. To order a non-latching product specify A in the description (ie. 56ARCD20 or 56C310ARCD). To order a latching product refer to the descriptions below. Available in high impact grey and chemically resistant orange and white. Specify GY, RO or RW.

Note: All products are sold less enclosure (LE) as standard. Not available in 10mA. FEATURES: 30mA rated tripping current for personal protection IP66 weather protection rating Self-locking cover ap Double pole switching Power consumption 16W at 240V

95mm
230/240V a.c.

30mA

I n

Residual Current Device

56 RCD RED BLACK ON OFF

RESET TEST
TEST BEFORE USE. DO NOT USE IF TEST FAILS

190mm
10A
SINGLE PHASE 50Hz IP 66

CAT No. 56 C 310RCD-30

Cat No Rated Operational Voltage Ue (~50Hz)


28mm

56RCD20-30

56C310RCD-30

56C316RCD-30

56C320RCD-30

Volts

240

240

240

240

Rated Thermal Current Enclosed Description

Amps

20 RCD Module only

10 RCD Protected 10A Socket

16 RCD Protected CEE17 Socket (Blue)

20 RCD Protected 20A Socket

RCD MODULE Rated Tripping Current Rated Tripping Time SOCKET Number of Socket Pins (Including Earth ) Socket Conguration
56C310RCD-30 refer Pg 51

30mA 30mS

30mA 30mS

30mA 30mS

30mA 30mS

30mm

3 A Min Max 1.0 10 IP66 1.0 6 IP66

3 W 1.0 6 IP66

3 F 1.0 10 IP66

Cable Cross Section Solid or Stranded mm2 IP Rating

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

25

RCD Protected Outlets IP66


NEW
Portable Protected Socket Outlets
Two new products for the building and trade industry. Rugged construction using 56 Series and Merlin Gerin technology. Features an easy to carry handle and hanging facility, 2m heavy duty exible card set, RCD and overload protection, IP66 rated, and complies with AS/NZS3012 for construction and demolition sites. They are available in chemically resistant orange as standard for the electrical industry.

56C310EL2PRO

Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Description Volts Amps

56C310EL2P 240 10 RCD and Overload Protected Socket 10A Plug

56SO4ELP15

Dimensional
240 15 RCD Protected 10A Socket 15A Plug

Drawings

296mm

RCD MODULE Rated Tripping Current Rated Tripping Time SOCKET Number of Socket Pins (Including Earth ) Socket Conguration
refer Pg 51

30mA 100mS

30mA 100mS

235mm

3 A Min Max n/a

3 A n/a
56S04ELP15

90mm

Cable Cross Section Solid or Stranded mm2 IP Rating

IP66

IP66

26

Appliance Inlets IP66

56AI310GY

56AI532GY

Dimensional Drawings
94mm

PDLs Appliance Inlets can be used with any appropriately rated cord connector maintaining the IP66 rating. Appliance Inlets are to be mounted vertically into a standard 2 gang or larger enclosure. Note: 56AI310 and 56A1315 t on a standard 56E1 enclosure. A captive clear cover is provided for sealing out water and dust to maintain the IP66 rating
94mm

when not in use. These are available as a spare: Cat 56PC. Available grey (GY) only, except 56AI310 and 56AI315 available in chemically resistant orange (RO) and white (RW). Note: All products are sold less enclosure (LE) as standard.

Cat No Rated Operational Voltage Ue (~50Hz)


28mm

56AI310 Volts Amps 250 10 3 A Min Max 1 6 IP66 *

56AI315 250 15 3 D 1 6 IP66**

56AI320 250 20 3 f 1 6 IP66

56AI332 250 32 3 g 2.5 16 IP66

56AI416 500 16 4 h 1 6 IP66

56AI420 500 20 4 j 1 6 IP66

56AI432 500 32 4 k 2.5 16 IP66

Max. Thermal Current Enclosed Number of Pins (Including Earth )

Pin Conguration refer Pg 51 Terminal Capacity mm2


25mm
56AI310 and 56AI315
95mm

IP Rating

* when used with 56CSC310 only ** when used with 56CSC315 only

Cat No
192mm

56AI440 Volts Amps 500 40 4 l^ Min Max 2.5 16 IP66

56AI450 500 50 4 m 4 16 IP66

56AI516 500 16 5 n 1 6 IP66

56AI520 500 20 5 o 1 6 IP66

56AI532 500 32 5 p 2.5 16 IP66

56AI540 500 40 5 q 2.5 16 IP66

56AI550 500 50 5 r 4 16 IP66

Rated Operational Voltage Ue (~50Hz) Max. Thermal Current Enclosed Number of Pins (Including Earth )

78mm 28mm

Pin Conguration refer Pg 51 Terminal Capacity mm2

IP Rating

70mm

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

56AI320 to 56AI550

27

Plugs IP66

56P310

56PA320

56PA332

250V Plugs
The 56 Series Single Phase plugs are available in 10A, 15A, 20A and 32A pin congurations to suit the Australian and New Zealand markets and in the British 13A square pin conguration. All nine plugs are IP66 rated when in use with 56 Series IP66 sockets, combination switched sockets, and RCDs. The popular small frame sized plugs were fully redesigned and re-launched in 2003 to meet todays market requirements. They are designed with the food industry in mind, removing signicant dirt gathering areas, and with a better lock-ring for easier use.
Cat No (Straight) Cat No (Angled) Rated Operational Voltage Ue (~50Hz) Max. Thermal Current Enclosed Number of Pins (Including Earth Pin Conguration
refer Pg 51

As well as this they are designed for the installer, incorporating an improved cable entry, a hinged single screw cord clamp, and an improved terminal layout. FEATURES: Transparent body IP66 rated M20 rear thread on small frame size plugs, allowing exibility in cable connection All plugs feature the certainty of a cord clamp and convenience of rear cable entry for terminals

Dimensional Drawings

67mm 42mm

12mm

31mm

20mm

28.5mm

112.5mm

56P310

56P310

56P310R

56P315

56P313

56P320F

56P320 56PA320 250 20 3 (Round) f 7 16 1 6

56P332 56PA332 250 32 3 (Round) g 10 27 2.5 16

78mm 55mm

Volts Amps

250 10 3 (Flat) A

250 10 2 (Flat) & 1 (Round) B 7 11 0.75 1.5

250 15 3 (Flat) D 7 11 1.0 1.5

250 13 3 (Square) C 6 10 0.75 1.5

250 20 3 (Flat) E 7 11 1.0 1.5

20mm 20mm 85mm

56P313

Cable Entry Diameter mm

Min Max Min Max

7 11 0.75 1.5

Terminal Capacity mm2

Plugs are available in orange/clear as standard and chemically resistant orange and can be ordered by adding V to the catalogue number. Eg: 56PAV320. These plugs are fully orange without clear bodies.

NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

28

Plugs IP66

56PV432

56P432RF

56PA416

Dimensional Drawings

500V Plugs
These plugs are all rated IP66 when tted to a 56 Series cord connector or Socket Outlet. The body section is transparent for quick and easy inspection of the terminals and cable entry. Plugs are available with 4 to 7 pins, 16A to 50A to cover most applications.
48mm62mm

Plugs are available in orange/clear standard and chemically resistant orange and can be ordered by adding V to the catalogue number. Eg: 56PAV320. These plugs are fully orange without clear bodies.

78mm 52mm

Cat No (Straight) Cat No (Angled)


19mm 152mm

56P416 56P416K** 56PA416 56PA416K Volts Amps 500 16 4 h Min Max Min Max 7 16 1 6 500 16 4 i 7 16 1 6

56P420 56PA420 500 20 4 j 7 16 1 6

56P432 56PA432 500 32 4 k 10 27 2.5 16

56P432RF* 56P440 56PA432RF* 56PA440 500 32 4 k 10 27 2.5 16 500 40 4 l^ 10 27 2.5 16

56P450 56PA450 500 50 4 m 10 27 4 16

56P516 56PA516 500 16 5 n 7 16 1 6

56P320 to 56P720 (16A ~ 20A)

Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Pins (Including Earth
108mm

78mm 52mm

Pin Conguration
refer Pg 51

19mm

Cable Entry Diameter mm


149mm

48mm

56PA320 to 56PA720 (16A ~ 20A)

Terminal Capacity mm2

78mm 59mm

58mm 68mm

** Special keyway for high cycle applications * RF Reefer Version with narrow locking ring for refrigerated container applications

20mm

176mm

56P432 to 56P550 (32A ~ 50A)

78mm 59mm

123mm 20mm

164mm

58mm

56PA432 to 56PA550 (32A ~ 50A)

29

Plugs and Switched Pendant Outlet IP66


Cat No (Straight) Cat No (Angled) Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Number of Pins (Including Earth ) Volts Amps 56P520 56PA520 500 20 5 o Min Max Min Max 7 16 1 6 56P532 56PA532 500 32 5 p 10 27 2.5 16 56P540 56PA540 500 40 5 q 10 27 2.5 16 56P550 56PA550 500 50 5 r 10 27 4 16 56P616 56PA616 500 16 6 s 7 16 1 6 10A 56P716 56PA716 500 16 7 t 7 16 1 6 10A 56P720 56PA720 500 20 7 u 7 16 1 6 10A

Pin Conguration refer Pg 51 Cable Entry Diameter

Terminal Capacity mm2

Auxiliary Pins C1C2 Maximum Current

Dimensional Drawings

NEW

Chemically resistant orange

78mm 52mm

48mm62mm

Switched Pendant Outlet


19mm 152mm

A 56 Series Switched Pendant Outlet that combines safety, performance, and functionality. An IP66 rated outlet that allows the ability to disconnect the supply without unplugging and from a prominent location.
FEATURES: A positive activating slide switch Double pole switching Built-in hanging facility New easy-use connector ap Ample wiring room Optional neon indication

56P416 to 56P720 (16A~20A)

78mm 52mm 108mm

19mm

149mm

48mm

56PA416 to 56PA720 (16A~20A)

Available in chemically resistant orange only. Specify RO.

78mm 59mm

164mm

Cat No Rated Operational Voltage Ue (~50Hz) Max. Current Enclosed Number of Pins (Including Earth ) Volts Amps

56SP0310 250 10 3 A 1 way Double Pole Min Max Min Max 7 11 0.75 2.5 IP66

56SP0315 250 15 3 D 1 way Double Pole 7 11 0.75 2.5 IP66

56SPO310RO

56P432 to 56P550 (32A~50A)

78mm 59mm

123mm 20mm

Socket Conguration refer Pg 51 Switch Description

164mm

58mm

Cable Entry Diameter

56PA432 to 56PA550 (32A~50A) NOTES: For pin congurations refer to inside back cover 56 SeriesTM Product Master Page 51

Terminal Capacity mm2

IP Rating

Available early 2007

New switched pendant outlets

30

Cord Connectors IP66

56CSC310

56CR420

56CR432

Cord Connectors
Dimensional Drawings
PDLs Cord Connectors can be used with any 56 Series Plug or Appliance Inlet maintaining the IP66 protection. The body section and ap are both transparent for quick and easy identication of the socket conguration and the cable termination.
12.1mm 31mm 65mm

Available in orange/clear as standard, and also can be ordered by adding a V to the stock code (i.e. 56CRV310), or RO for the CSCs (i.e. 56CSC310RO). These connectors are fully orange.

55.2mm

Cat No Rated Operational Voltage Ue (~50Hz) Maximum Current Enclosed Number of Socket Pins (Including Earth ) Volts Amps

56CSC310 56CR310 250 10 3 A Min Max Min Max 7 11 1 1.5 IP66* 250 10 3 A 6 9 0.75 1.5 IP66

56CSC315 56CR315 250 15 3 D 7 11 0.75 1.5 IP66** 250 15 3 D 7 11 0.75 1.5 IP66

56CR320 250 20 3 F 7 16 1 6 IP66

56CR332 250 32 3 G 10 27 2.5 16 IP66

56CR416 500 16 4 H 7 16 1 6 IP66

56CR420 500 20 4 J 7 16 1 6 IP66

105.1mm

56CSC310 to 56CSC315

85mm 55.2mm

12.1mm

31mm

Socket Conguration
refer Pg 51

120mm

Cable Entry Diameter mm

56CR310 to 56CR315 Terminal Capacity mm2

IP Rating
96mm
21mm 69mm

* when used with 56AI310 ** when used with 56AI315


Cat No 56CR432 Volts Amps 500 32 4 K Min Max Min Max 10 27 2.5 16 IP66 56CR440 500 40 4 L 10 27 2.5 16 IP66 56CR450 500 50 4 M 10 27 4 16 IP66 56CR516 500 16 5 N 7 16 1 6 IP66 56CR520 500 20 5 O 7 16 1 6 IP66 56CR532 500 32 5 P 10 27 2.5 16 IP66 56CR540 500 40 5 Q 10 27 2.5 16 IP66 56CR550 500 50 5 R 10 27 4 16 IP66

140mm 155mm

Rated Operational Voltage Ue (~50Hz) Maximum Current Enclosed Number of Socket Pins (Including Earth ) Socket Conguration
refer Pg 51

77mm

56CR 16A to 20A

Cable Entry Diameter mm


96mm
58mm 69mm

Terminal Capacity mm2

120mm 186mm

IP Rating

77mm

56CR 32A to 50A

31

DIN Mounting MCB/RCD Covers IP66

56CB4GY with MG 23358 RCCB

56CB13

DIN Rail Mounting Covers for MCBs, RCDs or any full DIN mounting accessory.

Dimensional Drawings
Cat No Number of Poles Module Width Neon Voltage (~50Hz) DIN Rail Mounting Height IP Rating mm Volts Min Max 56CB4 4 72 (4x18) 415V/240V 48mm 62mm IP66 198mm 95mm

56CB4
Two gang cover that ts up to 4 poles (72mm) in width. Provided with 1x8mm DIN opening and 6x9mm breakouts. Supplied with full DIN rail and mounting bracket for tting to a standard 56E2 or larger enclosure. DIN rail and brackets (2) kit is available as a spare. To order, specify: 1CB100. FEATURES: IP66 rated Dual 415V/240V neon Clear pad lockable ap cover Available: Grey, orange, white. Note: Supplied less enclosure (LE) as standard.

56CB13
Thirteen way fully equipped distribution board. Fitted complete with DIN rail, 1 x Earth and 2 x Neutral bars as standard, all tted with links (where applicable) to a base enclosure the same size as a 56E6. FEATURES: IP66 rated Complies with AS/NZS3439.3 Clear pad lockable ap cover Supplied with accessory pack

Cat No Number of Poles Module Width Rated Operational Voltage (~50Hz) Rated Current of Board Rated Insulation Voltage Short Circuit Withstand Strength Dimensions (with enclosure) Cable Entries IP Rating mm Volts

56CB13 13 234 (13x18) 415V a.c. 100A with suitable rated cable (25mm) 1000V a.c. 10kA 295Wx123Dx198H 6x25mm, 2x32mm IP66
198mm 295mm
56CB4

28mm

Available: Grey only. Orange and white on request.

123mm
56CB13

32

Pendant Outlet Kits


Suspension hooks that can be tted to 56 Series Connectors, enabling a chain or cord to be attached for ceiling mounting.

Cat No

56POK Suits 10A to 20A Connectors

56POK1 Suits 32A to 50A Connectors

56POK and 56POK1

Dimensional Drawings

Module Mounting Lids


22mm Diameter
Lids for mounting either one or two 22mm diameter control modules. Lids can be supplied in grey, orange, white or clear for matching to any control accessories. Ideally suited for the Telemecanique Harmony range of pushbuttons refer to advertisement below.
Cat No Mounting Hole Size Mounting Holes Mounting Centres Colours Available 56L1/22/1 56L1/22/2

40mm 95mm

22.5mm with 3.5mm Keyway 1 2 40mm Grey, Orange, White or Clear

95mm

22.5mm

56L1/22/1 56L1/22/2

500 Series IP66 Covers


28mm

Cat No Mounting Hole Size Mounting Holes Mounting Centres

56MO500/1

56MO500/2

30mm 94mm

Covers to suit any PDL 500 or 600 Series module providing IP66 protection. Ideally suited for 500 and 600 Series switches, push buttons, dimmers and neon indicators.

For PDL 500 and 600 Series Module Only 1 2 30mm

94mm

56MO500/1 56MO500/2

Control & Signalling


from Telemecanique Harmony that meets all your application needs

Push Buttons Pilot Lights Selector Switches Joysticks Beacons Control Stations Pendants

33

Enclosures
Dimensional Drawings
23mm
63mm

102mm

102mm

56E1
102mm

20mm

35mm

102mm

56E1/25/25RW

56E8GY including dividers

56E1S
102mm

20mm
20mm

63mm

PDL 56 Series enclosures are in two types: shallow, in single and 2 gang sizes, suitable for mounting blank lids, single phase switches, single phase sockets and sunset switches; and standard 63mm deep enclosures, which range in size from single gang to 16 gang. They are moulded in impact resistant PVC.

All multigang enclosures are supplied complete with a selection of bridges to provide a sealing base between individual modules and dividers for separating incompatible circuits. Enclosures are supplied with a range of conduit entries according to the chart.
56E2
40mm 102mm

198mm

23mm
20mm

63mm

Cat No Module Size Module Conguration Dimensions

56E1S 1 Shallow

56E1 1

56E1/25/25 1

56E2S 2 Shallow

56E2 2

56E2 Food Industry 2

56E2/25/25 2

56E2/40 2
198mm

1x1

1x1

1x1

2x1

2x1

2x1

2x1

2x1

Length 102 Width 102 Depth 38 Conduit Entries Metric mm*

102 102 63

102 102 63

198 102 38

198 102 63

198 102 63

198 102 63

198 102 63
56E2/25/25
23mm
38mm

25 2 32 40

1 1

2 1

1 1

2 1

102mm

Conduit Reducers Supplied

25/20 1 32/25 1x25-20

1 1 1x32-25

2 1x32-25

1 2x25-20

1 1 1x32 1x25

2 1x32 1x25

2 1 1x25-20 1x32-25

1x25-20 1x32-25

197mm

Rear Entry Cut-Outs

* Special enclosure threaded entries are available on request. Specify grey (GY), orange (RO), or white (RW).
56E2S
40mm

20mm

102mm

23mm

63mm

102mm

56E1/25/25

20mm

34

Enclosures
20mm 63mm 102mm

Cat No Module Size Module Conguration Dimensions mm

56E3 3 3x1

56E4VH 4 4x1

56E4 4 2x2

56E6 6 3x2

56E8 8 4x2

56E9 9 3x3

56ED2/40 2 Extra Deep 2x1

56E16 16 4x4

Length 296 Width 102 Depth 63


391mm

396 102 63 1 1 ------2x25 1x32 1x40

198 198 63 2 4 --1 1 2x32-25 2x32 2x40

296 198 63 2 2 --1 1 2x25 2x32 2x40

396 198 63 2 2 ------4x25 2x32 2x40

296 296 63 3 3 --1 1 4x25 3x32 2x40

198 101 100 ----2 ----1x25 1x32

396 396 63

Conduit Entries Metric mm*

25 1 32 1 40 --25/20 1 32/25 1 3x32-25 1x32 1x40

4 4 4 4 8x25 4x32 4x40

Conduit Reducers Supplied

Rear Entry Cut-Outs


23mm

56E4VH
20mm 63mm 96.5mm 198mm

* Special enclosure threaded entries are available on request.

Dimensional Drawings
391mm
20mm

63mm

102mm

23mm

295mm

56E8

23mm 64mm 295mm

23mm

56E3
295mm

23mm 64mm 96.5mm 198mm

96.5mm 20mm

96.5mm

96.5mm 198mm

56E9

20mm

56E4
20mm 64mm 396mm

22mm 64mm 96.5mm 198mm

396mm

295mm

23mm

96.5mm

96.5mm

96.5mm

56E16

20mm

56E6

35

Lids
Dimensional Drawings
95mm 28mm

95mm

56L1
28mm 95mm

192mm

56L2RO tted to 56E2RO

56DL4CL tted to 56E4GY


56L2

56 Series Lids are available in 1 gang to 6 gang module sizes in both grey and clear, impact resistant polycarbonate or chemically resistant orange and white. Lids can be used in conjunction with enclosures or other product in the series to produce a wide range of power distribution centres or utility boxes.

Available in high impact grey and clear, or chemically resistant orange and white. Except 56XDL1 is only available in grey and clear. Specify GY, CL, RO or RW, i.e. 56L1GY.

96mm

30mm

289mm

Cat No Module Size Module Conguration Dimensions

56L1 1 1x1

56L2 2 2x1

56L3 3 3x1

56L4 4 2x2

56XDL1 1 1x1

56DL2 2 2x1

56DL4 4 2x2

56DL6 6 3x2
56L3
95mm 100mm

Length 95 Width 95 Depth 28

191 95 28

289 95 30

191 191 28

95 95 100

191 95 63

191 191 63

289 191 63
56XDL1
63mm

95mm

78mm

NOTE: All products come supplied less enclosure. Options are available tted with enclosure: 56 Series utility boxes in grey and clear, shallow and standard, with some tted with gear trays. Refer to the latest PDL pocket book for details.

95mm

192mm

56DL2
191mm
28mm

191mm

56L4
190mm 77mm

287mm

56DL6

36

Pendant Enclosures
Cat No 56PE2/25 1x25mm 1x25/20mm 1x2 56PE2/32 1x32mm 1x2

Dimensional Drawings
25mm 32mm 25mm or or 32mm threaded entry threaded entry

Conduit Entries Conduit Reducers Supplied Module Size

102mm

PDLs Pendant Enclosure allows you to mount two 56 SeriesTM single gang products in a fully enclosed, portable unit so you can hang up your power supply. A divider separates the two mounted products and produces a seal to ensure the IP66 rating.
30 90mm 102mm
18mm

Available in high-impact grey and chemically resistant orange and white.

In the interests of user convenience, the enclosure features nger recesses for holding while unplugging the plug from the socket.
18mm

They have a strong, large loop for attaching a chain, as well as angled cable entry for ease of wiring.

180mm

56PE2

The 56 Series Pendant Enclosure

Flush Surrounds
PDL 56FA Series Mounting Details

OFF

20A 500V THREE PHASE 50Hz IP66 CAT No 56 SW 320

ON

Mounting Flange

56FA1GY
Supplied with metal wall mounting plate and foam sealing gasket. Ideal for ush mounting of 1 to 4 gang accessories maintaining the IP66 protection. Moulded in impact resistant UV stabilised PVC. Available in grey (GY), orange (RO), and white (RW).
Mounting Plate

56FA2GY
Cat No Module Size Module Conguration Dimensions Length Width 157 157 254 157 350 157 254 254 56FA1 1 1x1 56FA2 2 2x1 56FA3 3 3x1 56FA4 4 2x2

Foam Sealing Gasket

Dimensional Drawings
157mm 84mm
84mm 180.5mm 84mm 11.5mm

11.5mm

Wall Cavity

84mm

157mm

84mm

157mm 84mm

84mm

253.5mm

56 FA1

56 FA2

37

Accessories
Plug Body and Plug Sleeve Kits
The 56 Series has a comprehensive range of plug bodies and plug sleeve kits. These allow for the replacement of damaged plug bodies or sleeves through extensive use or misuse. They are available in all plug sizes from 16A up and in both standard impact resistant polycarbonate or chemical resistant orange. Plug bodies also t 56 Series cord connectors. PLUG BODIES:
Cat No 56P16/20A 56PA16/20A 56P32/35A 56PA32/35A 56P40/50A 56PA40/50A Description 16/20A Straight 16/20A Angled 32/35A Straight 32/35A Angled 40/50A Straight 40/50A Angled
TM

Socket Covers
Two covers cater for all 56 Series standard socket products to allow safe replacement of damaged covers.
Cat No Description 56SOCVR Socket Cover General 56SOCVR10 Socket Cover 10A, 15A

Plug Body

Gaskets
Replacement gaskets for worn or damaged units, as well as gaskets for improved protection in high pressure wash down situations.
Cat No 56L1GASKET 56L2GASKET 56HPG1 56HPG2/1 56HPG2/2 Description Single Module Gasket Double Module Gasket High Pressure 1 Gang High Pressure 2 Gang, 1 Piece High Pressure 2 Gang, 2 Piece

Plug Sleeve

NEW

PLUG SLEEVE KITS:


Cat No 56P16 56P20/250 56P32/250 56P20/500 56P32/500 56P40 56P50 Description 16A 20A 3 pin 32A 3 pin 20A 4+ pin 32A 4+ pin 40A 50A

Enclosures
Replacement parts to suit 56 SeriesTM enclosures.
Cat No 56BRIDGE 56DIVIDER 3S130 Description Enclosure Bridge Enclosure Divider Enclosure Mounting Pillar

Mounting Feet

Mounting Feet and Indenticaps


Mounting for 56 Series enclosures enabling the boxes to be recessed out from the wall or mounting area. An advantage for high quality hygiene areas. RED/YELLOW/BLUE to t all covers available in single colour packs of 20 or a mixed pack of 60. To order, specify NO9 and the colour, for example: NO9 BLUE. Also available in grey, orange and white.
Cat No Material Stand off height Mounting Centres Package Contents Mounting Feet Mounting Screws 56MF 316 Stainless Steel 9.0mm 82mm 2 4

NO9 Caps

Socket Cover

56HPG1

56HPG2/1

56HPG2/2

38

PDLs 56 SeriesTM D.O.L. Motor Starters


The Watertight Motor Starter Solution with features designed to outperform all others
56 SeriesTM Compatible IP66 Protection NZ Made for NZ Conditions Combination Isolating Switch/D.O.L. Motor Starter

1 2

Pre-wired Unique cover mounted contactor and overload (allows for rst tting of enclosure and conduit if required) Both 230V and 400V versions available AC23 11kW motor rated switch Maximum contactor rating 5.5kW (7.5hp) 1x25mm conduit entry 2x20mm conduit entries Finger proong on all terminals

Shrouded push buttons

10 Available with or without enclosure 11 High impact resistant UV stabilised polycarbonate cover 12 Raised stop button 13 Enclosure manufactured from UV stabilised rigid PVC 14 Easy adjustment of overload setting, no tools required 15 Terminal screws combination slot-pozi head

3 4 5 6 7 8

3 5

10

For tough motor control situations!


A range of rugged, dependable D.O.L. Motor Starters, for single phase motors up to 2.2kW (3.0hp) and three phase motors up to 5.5.kW (7.5hp). For maximum versatility and exibility there are four versions in each of the single and three phase options: 1 START/STOP RESET 2 STOP/RESET ONLY 3 START/STOP RESET with isolating switch 4 STOP/RESET with isolating switch

13

1 8 2

11

15

14
12

39

Products in the Motor Starter Range IP66


Dimensional Drawings
102mm 96mm 40mm
20mm conduit entry (x2)

198mm

56MS230E

56MS230R
3mm

192mm
25mm conduit entry (x1)

123mm 105mm 63mm 17.5mm

56MS400SWE
Product Descriptions

56MS400SWR

20mm 116mm

40mm

56MS230R
Coil voltage 230V~50Hz Stop/Reset Control only Less enclosure

56MS230
Coil voltage 230V~50Hz Start and Stop/Reset Controls Less enclosure

102mm 96mm
20mm conduit entry (x2)

56MS400R
Coil voltage 400V~50Hz Stop/Reset Control only Less enclosure

56MS230E
198mm 192mm

Coil voltage 230V~50Hz Start and Stop/Reset Controls With enclosure

56MS230SW
Coil voltage 230V~50Hz Start and Stop/Reset Controls With isolating switch Less enclosure

56MS400
Coil voltage 400V~50Hz Start and Stop/Reset Controls Less enclosure
3mm

56MS230SWE
Coil voltage 230V~50Hz Start and Stop/Reset Controls With isolating switch With enclosure

56MS400E
Coil voltage 400V~50Hz Start and Stop/Reset Controls With enclosure

25mm conduit entry (x1)

105mm 63mm 17.5mm

56MS400SW
Coil voltage 400V~50Hz Start and Stop/Reset Controls With isolating switch Less enclosure

56MS230SWR
Coil voltage 230V~50Hz Stop/Reset Control only With isolating switch Less enclosure

56MS400SWE
Coil voltage 400V~50Hz Start and Stop/Reset Controls With isolating switch With enclosure

56MS400SWR
Coil voltage 400V~50Hz Stop/Reset Control only With isolating switch Less enclosure

20mm 116mm

* Note: Products supplied less enclosure unless specied in stock code and descriptions above. Available in grey as standard, chemically resistant orange and white on request.

40

Connection Diagrams
TECHNICAL INFORMATION Starter and Overload
GENERAL
Direct on Line Motor Starter Maximum Rated Output AC3 5.5kW 400V Three Phase AC3 2.2kW 230V Single Phase Maximum Thermal Current Enclosed: 16A IP66 Dust and Watertight AS 1939:1990 BS 5490:1985 IEC 529 :1989 Finger proof terminals on contactor, overload and isolating switch to IP20
E

Typical connection diagrams for motor starter options, full instructions and connection diagrams are supplied with products.

3 Phase 3 Wire Supply 56MS400SW


MAINS SUPPLY L1 L2 L3 ON OFF

3 Phase 3 Wire Supply 56MS400


MAINS SUPPL Y L1 L2 L3 1 3 5 A1
400

E 13 1 C 96 95 2 START

A2 1 A1
400

14 98

13 1 C 96 95 2 START 2 4 6

STOP RESET

A2

14 98

U V W MOTOR LOAD STOP RESET

3 Phase 4 Wire Supply 56MS230


N MAINS SUPPLY L1 L2 L3 1 3 5 E 13 1 A1
230

U V W MOTOR LOAD

CONTACTOR
Type: S12 10 Electromagnetic Contactor 3 pole + N/O Auxiliary Frequency: 50Hz AC Utilisation Category: AC3 7.5kW 400V Three Phase AC3 2.2kW 230V Single Phase Rated Insulation Voltage Ui: 690V~ Rated Thermal Current Enclosed: 16A Coil Characteristics: Pull in 0.85 - 1.1 Uc (Control Circuit Voltage) Drop Out 0.4 - 0.6 Uc Terminal Capacities: Stranded 0.5 - 2.5mm2 Solid 0.75 - 4mm2

Remove link between A1 and 1 at terminal 1 on contactor and connect to neutral.


2 START C 96 95

3 Phase 4 Wire Supply 56MS230SW


MAINS SUPPLY Remove link between A1 L1 L2 L3 and 1 at terminal 1 on

A2

14 98

contactor and connect to neutral.


N E ON OFF 2 1 A1
230

STOP RESET

13 1 C 96 95 2 START

U V W MOTOR LOAD

Remove link wire attached to contactor terminal 3.

Single Phase & Neutral Supply 56MS230


MAINS SUPPLY N E A 5 13 1 A1
230

A2

14 98

STOP RESET

2 START C 96 95

ENCLOSURE
Rigid PVC UV stabilised, impact resistant. Screwed Conduit Entries Back Entry Cut-Outs 1 x 25mm 1 x 32mm 2 x 20mm 1 x 25mm

U V W MOTOR LOAD

Connect link wire attached to contactor terminal 3 to switch.

A2

14 98

Single Phase & Neutral Supply 56MS230SW


MAINS SUPPLY N A ON OFF 2 4 6 N A MOTOR LOAD

STOP RESET

MOTOR RATED ISOLATING SWITCH


Used with 56MS230SW, 56MS400SW, 56MS230SWR, 56MS400SWR 3 pole isolating. Motor rated to AC23 11kW 415V BS5419 M110 20A 500V AS3133

Connect link wire attached to contactor terminal 3 to terminal 6 on overload.

Remote Controls
REMOTE STOP/START PUSH BUTTONS

1 A1
230

13 1 C 2 START 13

14 96 START STOP

A2

14 98 95

START PUSH BUTTON SWITCH


Rated Insulation Voltage Ui: 500V Rated Thermal Current: 16A Utilisation Category: AC11 4A AC11 2A AC 250V 415V
2 4 6 A N MOTOR LOAD

96

STOP RESET

Connect link wire attached to contactor terminal 3 to terminal 6 on overload.

Remove link between 14 and 96 on starter and connect as shown.

REMOTE STOP PUSH BUTTON 14 STOP 96

OVERLOAD
Full Load Current Rating: 0.40 - 16 Amps in 10 size ranges Rated Insulation Voltage Ui: 660V AC Single Phase Protected Temperature Compensated: From 0 - 35C Manual or Auto Reset: Manual Test Incorporated: Alarm Control: N/O

Auxiliary Contacts
Rated Insulating Voltage: 500V AC Rated Operational Current le: AC11 2A 500V

Terminal Capacities
Main: Auxiliary: Stranded 0.5 - 2.5mm2 Solid 0.5 - 4mm2 Stranded 0.5 -2.5mm2 Solid 0.5 - 2.5mm2

41

Overload Selection
TECHNICAL INFORMATION International Standards and Approvals
DIRECT ON LINE MOTORSTARTER
International Protection IP66 to AS 1939:1990 and BS 5490:1977. AS 1202 Pt 1:1981 AC Motorstarters Direct on Line BS 4941 Pt 1:1979 Direct on Line AC Starters IEC 947, switch operation and cover marking Patented Stop/Reset Mechanism The switched versions (56MS400SW and 56MS230SW) comply with New Zealand Electrical Wiring Regulation 108. Manufactured to ISO 9001

Replacement Coils
Cat No 56MSC230 56MSC400 56MSC24 Description 230V~50Hz Coil 400V~50Hz Coil 24V~50Hz Coil

Overloads
Cat No 56T9062 56T9092 56T913 56T919 56T928 56T942 56T962 56T992 56T9120 56T9160 Description 0.4-0.62A 0.6-0.92A 0.85-1.3A 1.2-1.9A 1.8-2.8A 2.7-4.2A 4.0-6.2A 6.0-9.2A 8.0-12.0A 11.0-16.0A

CONTACTOR
IEC 947 EN 60947 VDE 0660 Manufactured to ISO 9001

OVERLOAD
IEC 292 VDE 0660 BS 587 and BS 5424 Manufactured to ISO 9001

Direct on Line Starter, Full Load Current


MOTOR RATING kW
0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5

THREE PHASE 400V ADJUSTMENT RECOMMENDED RANGE (A) OVERLOAD


0.6-0.92 0.6-0.92 0.85-1.3 1.2-1.9 1.8-2.8 2.7-4.2 2.7-4.2 4-6.2 6-9.2 6-9.2 8-12 56T9092 56T9092 56T913 56T919 56T928 56T942 56T942 56T962 56T992 56T992 56T9120

SINGLE PHASE 230V ADJUSTMENT RANGE (A)


1.8-2.8 2.7-4.2 4-6.2 4-6.2 6-9.2 8-12 11-16

HP
0.25 0.33 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.5 7.5

RECOMMENDED OVERLOAD
56T928 56T942 56T962 56T962 56T992 56T9120 56T9160

Denition of Utilisation Categories


to IEC60947-3 BS 5419

AC23A:
Switching of motor loads or other highly inductive loads. Occasional: Making 10 times le (Rated operational current) Breaking 8 times le

AC3:
Starting of squirrel cage motors, and switching off motors during running. Occasional: Making 10 times le Breaking 10 times le

NOTE: Full Load Currents given in this table are intended as a guide only. For exact full load current, consult the motor manufacturers specications or the motor nameplate.

THERMAL OVERLOAD CHARACTERISTICS Average values at 20c ambient temperature, tripping three phase from cold condition

Tripping Characteristics
wfrom hot condition kfrom cold condition
10000

SHORT CIRCUIT CAPABILITY


Setting Range (A) Max. Fuse Ratings (A) quick+) slow+)

AC11:
Feed control of magnetic drives, contactors, valves and electromagnets.

1000

100

10

tripping time/s

0.1

0.01

0.001

0.8

10

20

40

60

100

0.40 0.62 0.60 0.92 0.85 1.3 1.2 1.9 1.8 2.8 2.7 4.2 4 6.2 6 9.2 8 12 11 16

a 35 35 35 35 35 35

c 4 6 6 10 16 25 35 35 35 35

a 25 25 25 25 25 25 25

c 4 4 4 6 10 20 20 25 25 25

Occasional:
Making 11 times le Breaking 11 times le

nominal current

According to IEC 292-1A coordination types a and c.

42

Programmable Time Delay Module


3 operation modes On Delay with Manual Override, On Delay with no Manual Override, Off Delay with Manual Override. 32 Selectable time delays from 15 seconds up to 2 hours. Fits into a standard 600 Series module aperture. Interchangeable coloured face plates. Blue LED status indicator. 3A current rating. Also compatible with 800 Series.

NOTE: Product information page 16

Protected and Mobile to IP66


NEW PDL 56 Series Portable Protected Outlets
We have gone mobile for the building and trade industry. Check these features: c Industry proven 56 Series and Merlin Gerin technology c Rugged construction to IP66 c RCD & Overload protection c Two product options v 10A double combination switched socket outlets v 15A four gang integrally (auto) switched socket outlets c Easy to carry handle c 2 metre heavy duty flexible cord set c Available in Resistant Orange (RO) for the electrical industry

main egg image inside this egg, take off keyline

Ordering Information: Stock codes: 56C310EL2PRO (pictured) 56SO4ELP15RO

NOTE: Product information page 26

43

Technical Section
Chemical Resistance
Chemical Compatibility
56 Series Grey 56 Series Orange & White PDL Enclosures PBTA ABS

Chemical Compatibility

56 Series Grey

56 Series Orange & White

PDL Enclosures

PBTA

ABS

Acids Hydrochloric Acid (10%) Sulphuric Acid (10%) Acetic Acid (10%) Bases Potassium Hydroxide Sodium Hydroxide Ammonium Hydroxide Organic Solvents Ethyl Alcohol Methyl Alcohol Isopropyl Alcohol Heptane Acetone Methylethylketone Ethyl Acetate Methylene Chloride Ethylene Glycol Automotive Related Environments Motor Oil Transmission Fluid Power Steering Fluid C C C A A A N/T N/T N/T A A A C C C B B B N/T D D N/T N/T N/T A B A A D D D D A A A A N/T D D N/T N/T N/T A A A N/T D D N/T N/T N/T C C D N/T D D D N/T N/T C C D A A C A A B B B C N/T A B A A C A A A A A A A A A A B D

Brake Fluid Regular Petrol Premium Petrol Unleaded Petrol Diesel Fuel Salts Zinc Chloride (10%) Calcium Chloride (10%) Sodium Chloride (5%) Mechanical and Thermal Properties Outdoor Use Mechanical Properties Outdoor Use Colour Properties Indoor Use Lightweight High Rigidity Impact Resistance Glow Wire Test (GWT) UV Deterioration Ball Pressure Test

D D D D D B B B

A A A A A A A A

N/T A A A A B B B

A A N/T A N/T A A A

C D D D D B B A

A B A A B A 850C A 125C

A B A A B A 750C B 125C C 850C A 75C A 960C A 125C A A A A

D D A A C B 960C C 90C

RATINGS
This table is a guide only. Performance of product in a particular environment will be affected by a wide variety of factors, of which chemical compatibility is only one. End users should test for their particular environment. A Excellent B Good C Fair Compatible, no problems expected from the use of the chemical with this part. Acceptable, minimal loss of chemical properties after prolonged exposure. Marginally compatible, extended use of the chemical may cause deterioration and cracking of the part. Incompatible. Do not recommend the use of the chemical with this part.

D Poor N/T Not Tested

Rating Conversion
1 PHASE
kW
0.37 0.55 0.75 1.1 1.5 1.8 2.2 3 4 4.4 5.2 5.5 6 7 7.5

3 PHASE
hp
0.5 0.75 1 1.5 2 2.5 3 4 5 6 7 7.5 8 9 10

240V A
3.6 4.8 6.1 8.8 11.7 14.4 17.1 22.2 27.1 31.8 36.5 38.7 40.8 45.4 50

kW
0.37 0.55 0.75 1.1 1.5 2.2 3 3.7 4 5.5 7.5 9 10 11 15 18.5 22 25 30 33

hp
0.5 0.75 1 1.5 2 3 4 5 5.5 7.5 10 12 13.5 15 20 25 30 35 40 45

415V A
1.8 2.6 3.5 5 6.5 7.5 8.4 11 15 17 21 28 35 40 47 55 60

500V A
1 1.21 1.5 2.2 2.9 3.8 5 5.9 6.5 9 12 13.9 15 18.4 23 28.5 33 39.4 45 50

These values are given as a guide only. They may vary depending on the type of motor and the manufacturer.

44

Switch Rating Information


Glossary
IEC60947-3 Low Voltage Switchgear and controlgear Switches, disconnectors, switch disconnectors and fuel-combination units. Several ratings are referred to in detail. Note that ratings in the format AC21A can be interpreted as follows: AC refers to AC supply. Alternative is DC. 21 refers to the utilisation of the rating. Alternatives include 15, 23, 3 and detail on each can be found below. A refers to frequent operation. No number is specied for frequent operation, although the test programme tests at 30 second intervals. B is the alternative, covering infrequent operation, maybe one switching per day or month. AS/NZS3133 Approval and test specication Air break switches. Three different ratings are referred to in detail: Resistive rating M Motor rating X Inductive or uorescent rating

IEC60947-3 International Device Classications

= Disconnector (Isolating only)

An isolation device, under AS/NZS 3000:2000, section 2.8.3.2 must: Be capable of withstanding an impulse voltage likely to occur at the point of installation, or shall have an appropriate contact gap. Not be able to falsely indicate that the contacts are open.

= Switcher Disconnector (Or Switch Isolator-Making, Breaking and Isolating)

IEC60947-3 AC21A Switching of resistive loads including a moderate overload


Pure resistive loads include heating elements. Very few loads, if any, are 100% resistive and this test includes a moderate inductive component in recognition of this.

IEC60947-3 AC23A Switching of motor or other highly inductive loads


As above, this rating covers AC supply and frequent operation. AC23A is the best utilisation category for switching of the most common types of motors. Most other highly inductive loads typically involve motors of some type. Examples are heat pumps, compressors and air conditioners. The AC23A rating of a 56SW350GY switch is 35 Amps (18.5 kW). This switch can be matched to a motor that has a full load current of up to 35 Amps. Generally, these switches are used in conjunction with other motor control equipment such as motorstarters or soft starters and only have to operate during a fault or period of isolation.

IMPORTANT
The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for each particular application. No liability will be accepted for reliance on this information.

45

Switch Rating Information


IEC60947-3 AC3 Switching of squirrel-cage motors
AC3 has no A or B classication for frequency of operation and all ratings are for frequent operation. As described above. AC3 provides ratings directly applicable to the direct starting and switching off of motors during operation and as such is one of the harshest switch ratings available for motors. The AC3 rating of an 56SW350GY switch is 28 Amps (15kW). This switch can be used to start or stop a motor that has a full load current of up to 28 Amps. AC3 is the rating best suited for control equipment being turned on or off directly under load. Examples include conveyors, lathes and process equipment. With a frequent operation classication, these switches may be operated many times per hour.

IEC60947-3 AC4 Switching of squirrel-cage motors, starting, plugging and inching


Like AC3, AC4 has no A or B classication for frequency of operation and all ratings are for frequent operation. AC4 provides ratings in addition to AC3 relating to motors which are rapidly reversed while running (plugging), or operated repeatedly to obtain small movements of a mechanism (inching) and as such is one of the harshest switch ratings available for motors. The AC4 rating is applied only to the K and N control switches. The 56SW320CO has an AC4 rating of 1.5kW. This switch can be used to make or break a load of 1.5kW.

IEC60947-3 AC15 Control of electromagnetic loads


This rating covers the switch control of electromagnetic loads, including control devices such as relays, contractors, and valves.

IEC60947-3 DC21A Switching of DC resistive loads


As for AC21A except covers DC applications.

IEC60947-3 DC22A Switching of DC mixed resistive and inductive loads


As for DC21A except covers mixed resistive and inductive loads. For example shunt motors.

IEC60947-3 Rated short time withstand current (lcw/kA)


This is the recommended maximum current the switch can withstand under fault conditions without failing or showing signs of damage and is the switch equivalent of a 4.5kA or 6kA rating assigned to an MCB. Values are expressed as kA. A 56SW350GY switch has a 1.5kA rating so it can carry a 1500 Amp load for 1 second without damage. IEC60947-3 requires performance of at least 12x rated current for 1 second. 56 SeriesTM switches offer performance levels much higher than this.

IMPORTANT
The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for each particular application. No liability will be accepted for reliance on this information.

46

Switch Rating Information


IEC60947-3 Rated short circuit making capacity (1cm/kAp)
This rating provides performance information relating to the presence of a short circuit condition when the switch is switched ON. Values are given as kAp and indicate that current load can be carried until circuit protection devices activate. A 56SW350GY switch has a 2.1kAp rating so it can switch ON a 2100 Amp prospective short circuit and carry it for as long as the principal protection devices (MCB or Fuses) take to operate. A rated short circuit breaking capacity relates to the opposite switching OFF in the presence of a short circuit condition. This rating is not typically published as circuit protection devices are designed to act before a manual switch operation can be undertaken.

IMPORTANT Uninterrupted duty


The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of A duty without any off load application. period in which main contacts of equipment remain closed, whilst carrying a steady equipment for each particular No the liability will be accepted for reliance on this information. current without interruption for periods of more than eight hours (weeks, months or even years).

AS/NZS3133 Resistive rating


This rating is typically the one quoted most widely for a particular switch. The rating relates to resistive loads with a moderate inductive element. A 56SW350GY switch has a 50 Amp resistive rating so it can switch ON and OFF a resistive load of 50 Amps.

AS/NZS3133 M Motor rating


M rating indicates the switch is suitable for control of motors with a nominated locked rotor current of XX Amps MXX. A 56SW350GY switch has an M200 rating so it can switch ON or OFF under locked conditions a motor with a 200 Amp locked rotor current. The locked rotor current is generally eight to ten times the full load current and simulates current draw when a motor is stalled.

IMPORTANT
The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for each particular application. No liability will be accepted for reliance on this information.

47

IP Ratings
1st Figure
Protection against solid objects.

2nd Figure
Protection against harmful ingress of water. Protected against solid bodies larger than 12mm (e.g. nger of the hand).

2 3

Protected against vertically falling drops of water.

Protected against solid bodies larger than 2.5mm (e.g. tools, wire).

Protected against drops of water falling at up to 15 from the vertical.

Protected against solid bodies larger than 1mm (ne tools and small wires).

3 4 5

Protected against spraying water at up to 60 from the vertical.

Protected against dust (no harmful deposits).

Protected against splashing water from all directions.

Completely protected against dust.

Protected against jets of water from all directions.

Protected against jets of water of similar force to heavy seas.

48

Introducing to the New Zealand market the next level in power and performance for industrial wiring accessories, from the team that brought you the PDL 56 SeriesTM. Die-cast aluminium body for heavy impact and high temperature environments IP66 weather protection as standard Comprehensive range of Isolators, Changeover and Reversing Switches, Switched Socket Outlets and Junction/Utility Boxes An emphasis on user safety throughout the range Multiple switch ratings per product, allowing an exact match between product and application Numerous ease-ofinstallation advantages Some retrot switch options for simplied maintenance on existing Federal sites

For more information or a copy of our brochure please contact Customer Services on 0800 652 999.

Index
Cat No.
1CB100 3S130 56AI310 56AI315 56AI320 56AI332 56AI416 56AI420 56AI432 56AI440 56AI450 56AI516 56AI520 56AI532 56AI540 56AI550 56BRIDGE 56C310EL2P 56C310RCD-30 56C316RCD-30 56C320RCD-30 56CB13 56CB4 56CR310 56CR315 56CR320 56CR332 56CR416 56CR420 56CR432 56CR440 56CR450 56CR516 56CR520 56CR532 56CR540 56CR550 56CSC310 56CSC315 56CV310 56CV313 56CV315 56CV316/240 56CV320 56CV332 56CV416 56CV416K 56CV420 56CV432 56CV440 56CV450 56CV516 56CV520 56CV532 56CV540 56CV550 56CV616 56CV716 56CV720 56DIVIDER 56DL2 56DL4 56DL6 56E1 56E1/25/25 56E16 56E1S 56E2 56E2/25/25 56E2/40 56E2FOOD 56E2S

Page
32 38 27 27 27 27 27 27 27 27 27 27 27 27 27 27 38 26,43 25 25 25 17, 32 32 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 21 21 21 22 22 22 23 23 23 23 23 23 24 24 24 24 24 24 24 24 38 36 36 36 34 34 35 34 34 34 34 34 34

Cat No.
56E3 56E4 56E4VH 56E6 56E8 56E9 56ED2/40 56FA1 56FA2 56FA3 56FA4 56HPG1 56HPG2/1 56HPG2/2 56L1 56L1/22/1 56L1/22/2 56L1GASKET 56L2 56L2GASKET 56L3 56L4 56MF 56MO500/1 56MO500/2 56MS230 56MS230E 56MS230R 56MS230SWE 56MS230SWR 56MS400 56MS400E 56MS400R 56MS400SW 56MS400SWE 56MS400SWR 56MSC230 56MSC24 56MSC400 56P16 56P16/20A 56P20/250 56P20/500 56P310 56P310R 56P313 56P315 56P32/250 56P32/35A 56P32/500 56P320 56P320F 56P332 56P40 56P40/50A 56P416 56P416K 56P420 56P432 56P432RF 56P440 56P450 56P50 56P516 56P520 56P532 56P540 56P550 56P616 56P716 56P720 56PA16/20A

Page
35 35 35 35 35 35 35 37 37 37 37 38 38 38 36 33 33 38 36 38 36 36 38 16, 33 16, 33 40 40 40 40 40 40 40 40 40 40 40 42 42 42 38 38 38 38 28 28 28 28 38 38 38 28 28 28 38 38 29 29 29 29 29 29 29 38 29 30 30 30 30 30 30 30 38

Cat No.
56PA32/35A 56PA320 56PA332 56PA40/50A 56PA416 56PA416K 56PA420 56PA432 56PA432RF 56PA440 56PA450 56PA516 56PA520 56PA532 56PA540 56PA550 56PA616 56PA716 56PA720 56PB1/G 56PB1/R 56PB2G/R 56PC 56PE2/25 56PE2/32 56POK 56POKI 56RCD20-30 56SO310 56SO310/2 56SO310A 56SO313 56SO315 56SO315A 56SO316/110 56SO316/240 56SO316CEE 56SO320 56SO320F 56SO332 56SO332CEE 56SO416 56SO416CEE 56SO416K 56SO420 56SO432 56SO432CCEE 56SO432CEE 56SO440 56SO450 56SO4ELP15 56SO516 56SO516CEE 56SO520 56SO532 56SO532CEE 56SO540 56SO550 56SO616 56SO716 56SO720 56SOCVR 56SOCVR10 56SPO310 56SPO315 56SS10 56SW01 56SW110 56SW110/2 56SW110/2I 56SW116 56SW120

Page
38 28 28 38 29 29 29 29 29 29 29 29 30 30 30 30 30 30 30 14 14 14 32 37 37 33 33 25 18 18 18 18 18 18 18 18 20 18 18 18 20 19 20 19 19 19 20 20 19 19 26, 43 19 20 19 19 20 19 19 19 19 19 38 38 17, 30 17, 30 15 11 8 8 8 9 9

Cat No.
56SW120CO 56SW132 56SW15 56SW150 56SW210 56SW216 56SW220 56SW232 56SW250 56SW310 56SW316 56SW320 56SW320CO 56SW320FR 56SW320KG 56SW332 56SW332CO 56SW332KG 56SW340 56SW340KG 56SW350 56SW350/2 56SW363/2 56SW363KG 56SW420KG 56SW432KG 56SW620KG 56T9062 56T9092 56T9120 56T913 56T9160 56T919 56T928 56T942 56T962 56T992 56TC24HB 56TC7DB 56TCU 56TD 56XDL1 648TM NO9CAP WDL10

Page
13 9 11 9 8 9 9 9 9 10 10 10 13 13 12 10 13 12 11 12 11 11 11 12 12 12 12 42 42 42 42 42 42 42 42 42 42 14 14 14 16 36 16, 43 38 15

PDL 56 SeriesTM Product Master


Notes: 1. 56AI310 suits 56CSC310 only; 56AI315 suits 56CSC315 only 2. 56SPO310 & 56SPO315 RO only 3. All CEE17 sockets are available in grey only 4. 56P432RFR & 56PA432RFR reefer version with narrow locking ring for refrigerated container applications 5. 56SO432CCEE & matching plug & connector specically for international container equipment earth pin position = 3H 6. 56SO416K, 56CV416K, & matching plugs with a special keyway for high cycle applications where standard products should not be used.

50

Product Master
Description Conguration Female (SO, CV, CR, CSC, SPO) Ref Socket Outlet 56SO Combination Socket Outlet 56CV Connector 56CR or 56CSC or 56SPO Orange/Clear as standard. For RO add V to the stock code (i.e. 56CRV310), except CSC & SPO add RO Conguration Male (P, PA, AI) Ref Plug 56P or 56PA Orange/Clear as standard. For RO add V to the stock code (i.e. 56PV310 or 56PAV320). Not available in RW Appliance Inlet 56AI GY only except 3 pin 10A & 15A available in RO or RW on request Ordering Info GY, RO, RW GY, RO, RW

250V 3 pin (at) 10A Aust/NZ 3 pin (2 at & round earth) 10A Aust/NZ 3 pin 13A British 3 pin (at) 15A Aust/NZ 3 pin (at) 20A Aust/NZ 3 pin (round) 20A 3 pin (round) 32A 500V 4 pin (round) 16A 4 pin (round) 16A high cycle6 4 pin (round) 20A 4 pin (round) 32A 4 pin (round) 40A 4 pin (round) 50A 5 pin (round) 16A 5 pin (round) 20A 5 pin (round) 32A 5 pin (round) 40A 5 pin (round) 50A 6 pin (round) 16A 7 pin (round) 16A 7 pin (round) 20A CEE173 110V 3 pin (round) 16A 250V 3 pin (round) 16A
W

A B C D E F G

56SO310 56SO310A 56SO310R 56SO313 56SO315 56SO315A 56SO320F 56SO320 56SO332

56CV310, 56C310RCD30 56C310EL2P, 56SO4ELP15

56CR310, 56CSC310 56SPO3102

A B

56P310 56P310R 56P313 56P315 56P320F 56P320 56PA320 56P332 56PA332

56AI3101

56CV313 56CV315 56CR315, 56CSC315 56SPO3152

C D E

56AI3151

56CV320 56C320RCD30 56CV332

56CR320 56CR332

f g

56AI320 56AI332

H I J K L M N O P Q R S T U

56SO416 56SO416K 56SO420 56SO432 56SO440 56SO450 56SO516 56SO520 56SO532 56SO540 56SO550 56SO616 56SO716 56SO720

56CV416 56CV416K 56CV420 56CV432 56CV440 56CV450 56CV516 56CV520 56CV532 56CV540 56CV550 56CV616 56CV716 56CV720

56CR416

h i

56P416 56PA416 56P416K 56PA416K 56P420 56PA420 56P432, 56P432RFR4 56PA432, 56PA432RFR4 56P440 56PA440 56P450 56PA450 56P516 56PA516 56P520 56PA520 56P532 56PA532 56P540 56PA540 56P550 56PA550 56P616 56PA616 56P716 56PA716 56P720 56PA720

56AI416

56CR420 56CR432 56CR440 56CR450 56CR516 56CR520 56CR532 56CR540 56CR550

j k l^ m n o p q r s t u

56AI420 56AI432 56AI440 56AI450 56AI516 56AI520 56AI532 56AI540 56AI550

56SO316/110

W X

56SO316/240, 56SO316CEE 56SO332CEE

56CV316/240 56C316RCD30

BALS311 BALS31240 BALS31244

W X

BALS211 BALS21238 BALS21240

BALS2638

3 pin (round) 32A 400V 4 pin (round) 16A 4 pin (round) 32A 4 pin (round) 32A container5 5 pin (round) 16A 5 pin (round) 32A Notes: Refer to page 50.

Y Z Aa Bb Cc

56SO416CEE 56SO432CEE 56SO432CCEE 56SO516CEE 56SO532CEE BALS31423

Y Z Aa Bb Cc

BALS21349 BALS21351 BALS21485 BALS21239 BALS21241

51

Schneider Electric products are available through electrical wholesalers New Zealand wide. All PDL Electrical Products are designed to ISO 9001. Freecall: 0800 652 999, Freefax: 0800 101 152 Email: sales@nz.schneider-electric.com Online product detail: www.pdl.co.nz

NZPDL0206LEXCOM

NZPDL56SB1006

You might also like