You are on page 1of 10

PS1800 Centrifugal Pumping Systems

General Data and Sizing Tables


The curve show the performance range of 4 models at 1800Wp solar array irradiation of 6kWh/m on a tilted surface ambient temperature 30C

Solar tracking will improve performance by aprox 40%

Application:
drinking water supply livestock watering pond management irrigation

Solar Pumping System / Capacity Diagram


6kWh/m/day, 1800Wp solar array Pump meter head
50
SJ3-9
SJ12-3 SJ8-5 SJ5-8 SJ3-9

Lift Range
2- 12m head 2- 25m head 2- 40m head 20- 50m head

40

Curve is based on Irradiation 6kWh/m day, tilted surface Pump ends: SJ-xx = centrifugal pump Motor: brushless DC, maintenance free

30

SJ5-8

20

SJ8-5

SJ12-3

LORENTZ offers standard solar pump solutions up to 230m (760ft) head and special solutions up to 750m (2500ft) head. Ask for charts

10

0 20
Ver. 050820

40

60

80

100

120

140 m/day

160

Controller PS1800 controlling of the pump system and monitoring of the operating states mounted at surface (no submerged electronic parts) two control inputs for well probe (dry running protection), float or pressure switches, remote control etc. automatic reset 20 minutes after well probe turns pump off protected against reverse polarity, overload and high temperature speed control, max. pump speed adjustable to reduce flow rate to approx. 30 % solar operation: integrated MPPT (Maximum Power Point Tracking) battery operation: low voltage disconnect and restart after battery has recovered max. efficiency 92 % (motor + controller) enclosure: IP 54 (sealed, weatherproof)

Motor ECDRIVE 1200 HR / C brushless DC motor no electronics inside motor water filled IP68, pressure balanced, max. submersion unlimited dynamic slide bearings, material: carbon/ceramic wetted material: stainless steel (AISI 316), POM, rubber, cable drinking water approved

Pump End (PE) high life expectancy none-return valve dry running protection (optional) material: stainless steel (AISI 316)

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ3-9

C-SJ3-9
Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss
Head Metres /Ft.

US GPD m/day

45
11000

25 /83 30/100 35/116 40/132 50/165

40
10000 9000 8000 7000

35 30 25

6000 5000 4000 3000

20 15 10

2000 1000

Wp

300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Irradiation on a tilted surface kWh/m/day Internet: www.Lorentz.de BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ3-9.dwg Rev. Sep. 2005

PS1800 C-SJ3-9 (Item No. 1160 ) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

6,0 5,5 5,0 4,5 4,0


1000

Instantaneous Output
Average Values

25 m / 82 ft 30 m / 98 ft 35 m / 115 ft 40 m / 131 ft 45 m / 148 ft 50 m / 164 ft

1500 1400 1300 1200

55 m / 180 ft

1100

3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 200

900 800 700 600 500 400 300 200 100 0

400

600

800

1000

1200

DC Power [W]

1400

1600

Pump Type SJ 3A-9

A 546

B 186

Dimensions [mm] C D Emax 360 96 98

BSP 1 1/4"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 11,5 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,4kW / 2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

www.Lorentz.de

Rel. 051108

flow rate [US gal/h]

flow rate [m/h]

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ5-8

C-SJ5-8
Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C 5 /16.5 - 1% cable loss

80 US GPD m/day 70
17500

10/33

Head Metres /Ft.

15/49.5 20/66 25/82.5 30/100

60
15000

50
12500

35/115.5

10000

40

40/132 45/148.5

7500

30

50/165

5000

20

2500

10

Wp 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Irradiation on a tilted surface kWh/m/day
Internet: www.Lorentz.de BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-8.dwg Rev. Sep. 2005

PS1800 C-SJ5-8 (Item No. 1162 ) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

12,0
3000

11,0 10,0 9,0 8,0

Instantaneous Output

Average Values

5 m / 16 ft 10 m / 33 ft 15 m / 49 ft 20 m / 66 ft 25 m / 82 ft 30 m / 98 ft

2800 2600 2400 2200 2000 1800 1600 1400 1200 flow rate [US gal/h]

flow rate [m/h]

7,0 6,0 5,0 4,0 3,0 2,0 1,0 0,0 0 200 400 600 800 1000 1200
DC power [W]

35 m / 115 ft 40 m / 131 ft 45 m / 148 ft 50 m / 164 ft

1000 800 600 400 200 0

1400

1600

Pump Type SJ 5A-8

A 525

B 186

Dimensions [mm] C D Emax 339 96 98

BSP 1 1/2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 11,2 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,4kW / 2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

www.Lorentz.de

Rel. 051108

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ8-5

C-SJ8-5
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss

US GPD m/day

Head Metres /Ft.

130 120
30000

5 /16.5

110
10/33

100
25000

90 80
20000

15/49.5 20/66

70
15000

60 50

25/82.5 30/100

40 10000 30
5000

20 10

Wp 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Irradiation on a tilted surface kWh/m/day Internet: www.Lorentz.de BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ8-5.dwg Rev. Sep. 2005

PS1800 C-SJ8-5 (Item No. 1164) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

18

Instantaneous Output
16

4500

Average Values

5 m / 16 ft

4000

14

10 m / 33 ft 15 m / 49 ft

3500

12
flow rate [m/h]

20 m / 66 ft

10

25 m / 82 ft

2500

30 m / 98 ft

2000

1500

1000

500

0 0 200 400 600 800 1000 1200


DC power [W]

1400

1600

Pump Type SJ 8A-5

A 601

B 186

Dimensions [mm] C D Emax 415 96 98

BSP 2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 12,7 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,4kW / 2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

www.Lorentz.de

Rel. 051108

flow rate [US gal/h]

3000

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ12-3

C-SJ12-3
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss

US GPD m/day

200
50000

2.5/8

Head Metres /Ft.

5 /16.5

180
45000

7.5/25

160
40000

10/33

140
35000

12.5/41

120
30000

15/50

100
25000

20000

80 60 40 20

15000 10000

5000

Wp 300
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
2 3 4 5 6 7 8 9

Irradiation on a tilted surface

kWh/m/day
Internet: www.Lorentz.de

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ12-3.dwg Rev. Sep. 2005

PS1800 C-SJ12-3 (Item No. 1166) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

24 22 20 18
12,5 m / 41 ft

Instantaneous Output

6000

Average Values

5 m / 16 ft

5500
7,5m / 25 ft 10 m / 33 ft

5000 4500 4000 3500 flow rate [US gal/h]

16
flow rate [m/h]

15 m / 49 ft

14 12
3000

10 8 6 4 2 0 0 200 400 600 800 1000 1200


DC power [W]

2500 2000 1500 1000 500 0

1400

1600

Pump Type SJ 12A-3

A 566

B 186

Dimensions [mm] C D Emax 380 96 98

BSP 2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 12,5 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,4kW / 2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

www.Lorentz.de

Rel. 051108

Tank Height

Well to Basin Trans. Pipe Diameter

Cable Length

Trans. Pipeline Length

Static Level Riser Pipe Diameter Drawdown

Pump Intake Depth

Well Diameter

Depth of Well

You might also like