Bogen UTI1 Overhead Paging Implementation Guide

Implementation Guide

Publication History
First Release: Version 1.0 September 07, 2012

CHANGE HISTORY
Version
1.0

Date
9/07/2012

Change Details
Original Document Draft

Changed By
Mike Machnik

AUTHOR: Mike Machnik EarthLink Engineering

2
Proprietary and Confidential EarthLink Business

Implementation Guide

Table of Contents
Document Purpose ________________________________________________4 Product summary _________________________________________________4 Hardware Detail and Specifications _______________________________________4 Configuration Guide ________________________________________________5 Troubleshooting the Bogen UTI1 _________________________________________9

3
Proprietary and Confidential EarthLink Business

Implementation Guide

Document Purpose
The purpose of this document is to provide a detailed technical description and best practices for successful implementation of Bogen UTI1 overhead paging on EarthLink Business Line Side or Hosted PBX Product. This document provides information relative to the configuration standards for each device associated with the product. Also described within this document are product guidelines and product limitations. This document is to serve as product reference and guide to Engineering, Field Technicians, Remote Maintenance Support, Customer Vendor Support, Marketing and Sales personnel.

Product summary
The Bogen UTI1 will provide overhead paging which connects to an FXS port delivered to the customer via an Adtran 6355 onboard FXS port, Adtran TA9xx onboard FXS port, or Cisco SPA 2102 ATA. The Adtran CPE will provide the SIP signaling towards the network as it would in the standard Earthlink Business product.

Hardware Detail and Specifications


For specific hardware details regarding the Adtran CPEs, please see the Earthlink Business CPE matrix. The Bogen UTI1 device is a single unit which connects to the Earthlink Business CPE via an RJ11 connection. The speakers, amps, and inside wiring of such is provided by the customer and is a separate system from the Bogen UTI1.

4
Proprietary and Confidential EarthLink Business

Implementation Guide

Configuration Guide
Connect the Bogen UTI1 station port with RJ11 to the Earthlink Business FXS port. This FXS port could be provided by either Cisco SPA2102 or onboard FXS port on an Adtran CPE. On the Bogen UTI1 device toggle the switches to LS for loopstart and station.

To connect the Bogen UTI1 to the customers AMP, connect a single pair wire to the tip and ring of the Page Only terminal. The tip and ring wires are not pair specific. Connect the other end of the single pair wire to the customers AMP.

FXS port configuration on the Adtran CPE follows our standard Earthlink Business Line Side product. No other changes are necessary. See Earthlink Business Line Side MOPs for addition voice configurations. Adtran CPE example configuration for onboard FXS Port: FXS port Example signaling is Loopstart by default.

5
Proprietary and Confidential EarthLink Business

Implementation Guide

Voice User Example

Adtran CPE example configuration for Cisco SPA 2102 ATA: This follows the standard Earthlink Business Hosted configuration using the Adtrans Transparent SIP Proxy. See Earthlink Business Hosted MOPs for additional voice configurations. Ethernet Port Example

6
Proprietary and Confidential EarthLink Business

Implementation Guide

Metaswitch Configuration: The Cisco SPA 2102 will be built as a hosted seat using the EarthLink Business MOP for a Hosted Line.

7
Proprietary and Confidential EarthLink Business

Implementation Guide

The Adtran FXS line will be built as a standard EarthLink Business MOP for Standard Line.

8
Proprietary and Confidential EarthLink Business

Implementation Guide

Troubleshooting the Bogen UTI1


These troubleshooting tips have been provided by Doug Hoffman of Earthlink and are provided to assist the customers phone vendor when turning up this device. If you receive a busy signal after the page is completed, this means that the VOX setting on the UTI1 is set for too long. The VOX setting is the feature that tells the UTI1 how long to stay connected to the ATA, after hearing an absence of voice, before hanging up. Please refer to the manual on page 14 under System Parameters. You will have to use the analog phones to change a setting within the UTI1 by entering a code. Set the VOX setting to 2 seconds. The process is as follows: 1. Plug the analog phone into the override RJ-11 port with the phone cable and place the Program/Run switch to PROGRAM (PGM). 2. Pick up the phone and you will hear three beeps to confirm that you are in programming mode 3. Dial 5-1-2-# 4. You will hear two beeps to confirm that the programming has taken affect 5. Place the override switch back to RUN, Put the phone cable back in between the ATA and the UTI1 Station port, and retest

Refer to the manual for any questions, or feel free to call Bogen for any support. Their support engineers are easy to get a hold of, and very knowledgeable:

1-800-999-2809 Extension 2

9