Professional Documents
Culture Documents
| Tunnel Fans
Systemair 2013. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com
The characteristics of the equipment described in this catalogue (e.g., sizes, features, etc.) may be modified without prior notice. The catalogues published by SYSTEMAIR are reviewed and amended whenever necessary and any such modifications are made in new editions. The catalogue edition is printed on the inside back cover and the user is responsible for using the latest edition. Please visit our website at http://www.systemair.com
01/2013
BOX FANS | 3
KVD KVB
KVD (direct driven) and KVB (belt driven) from sizes 5/8 to 30/28* are a range of single skin supply or extract box fans for inline application. These fans are designed for cost effective installations with low to medium pressure drop whilst keeping very good sound performances. KVD Double inlet Direct Driven range with airflows from 250 to 7500 m3/h, IP 54 Class Motors single phase. KVB Double inlet belt driven range with airflows from 700 to 50000 m3/h IP 55 Class F motors (IE2 Motors).
Casing in galvanized steel with standard roof and feet for outdoor installation
Accessories
KVD: outlet hood, terminal box, power switch, pressure switch. KVB: outlet hood, power switch, pressure switch.
* The units from 20/20 to 30/28 with Aluminium Profile without isolation.
4 | BOX FANS
KPD KPB
KPD (direct driven) and KPB (belt driven) from size 7/7 to 30/28 are a range of supply or extract box fan for inline. The casing is made of an aluminum frame with single skin or double skin galvanized steel panels (upon request). These fans are designed for indoor and outdoor installations with low to medium pressure drop whilst keeping very good sound performances. KPB Double inlet belt driven range with airflows from 700 to 50000m3/h IP 55 F Class IEC motors (IE2 Motors) (380 V 50 and 60 Hz). Suitable for operating temperatures of up to 50C.
Accessories
KPD and KPB: outlet and inlet hood, power switch, pressure switch, filter, roof, double skin, damper, inlet panel with rectangular flange.
BOX FANS | 5
6 | BOX FANS
Green/yellow
Black
Blue
Star connection
BOX FANS | 7
A'' A
B'
Note: All dimensions in mm. See the information for KVB sizes 20-20 to 30-28 in page 10.
8 | BOX FANS
Inlet options
Manual damper L Length 300 350 350 400 450 H Height 288 288 288 416 416
Rectangular inlet L Length 390 440 440 490 570 H Height 390 440 440 490 570
Inlet options
Manual damper L Length 300 400 400 500 500 650 650 800 800 900 H Height 288 416 416 416 416 544 544 672 672 800
Rectangular inlet L Length 390 490 490 590 590 740 740 890 890 1000 H Height 390 490 490 540 540 640 640 740 740 900
Note: All dimensions in mm. See the information for KPB sizes 20-20 to 30-28 in page 10.
BOX FANS | 9
Manual damper L Length 1000 1000 1200 1400 H Height 1056 1056 1184 1312
10 | BOX FANS
9-7
46% 50% 150 140 130 120 110 100 90 80 70 60 50 40 1800 1600 2000
49% 45%
59%
65%
67%
65% 60%
51% 2400
3100 39%
20
20
1400
500 3
1000 4 1 5 2 3
1500 2000 10 4 5 10
15
1000 4 5 1 2
1500
2000 10
pd (mm H2O)
pd (mm H2O)
4 5
10
30 40 50
9-9
150 140 130 120 110 100 90 80 70 60 50 1600 40 1500 1400 30 1300 1200 1100 1000 900 800 10 700 10 30 40 2000 1800 60% 67% 70% 69% 63% 53%
10-8
2400 150 140 130 120 110 100 90 80 70 60 50 1800 1700 1600 1500 1400 1300 1200 1100 1000 20 900 800 69% 68% 62% 2200 52%
66% 60%
20
700
600
600
1000 3 4 1
1500 5 2
2000
3000 10 4 5
pd (mm H2O)
30 40 50
pd (mm H2O)
30 40 50
BOX FANS | 11
12-9
2200
64%
60%
1600
600
1000 3
1500 2000 4 5 1 2 3
3000 4000 10 4 5 10
15
1000 3
1500 4 1
2000 5 2 3
3000
4000 10 10
6000 15 20
pd (mm H2O)
pd (mm H2O)
4 5
12-12
150 140 130 120 110 100 90 80 70 60 50 40 68% 69% 60% 1800
30 800
20
700
600
10
500
1500 3
2000 4 5 1 2
3000
4000 10
6000
8000 10000 15 20 20
15000 20000 30 40 70
pd (mm H2O)
4 5
10
30 40 50
Note: All these fan curve are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point.
12 | BOX FANS
15-15
66%
150 140 130 120 110 100 90 80 70 60 50 40 900 800
58%
64%
64%
800
30
700
30
700
20
600
600 20 500
500
10 400
10
400
1500 3
2000 4 1
3000 5 2
4000
6000 10 10
8000 10000 15 20 20
15000 20000 30 40 30 40 50 70
2000 3
3000 4000 4 5 1 2 3
15000 20000 20 30 30 40 50 70
30000 40
pd (mm H2O)
4 5
pd (mm H2O)
18-18
150 140 130 120 110 100 90 80 70 60 800 50 40 700
pt (mm H2O)
20-20
71% 1200 64%
120 110 100 90 80
73%
Not usable NO UTILIZABLE UTILIZABLE SEGUN SERIE Not recommended NO RECOMENDADO Not recommended
3.0
5.0 4.0
6.0
70% 70%
9. 0
64% 52%
65%
70 60 50 40
1000
2.0 1.5
700
900 800
1.0
(kW
30
300
PA
30
600
20
450 400
10
450 400
n (m
in
20
0.3
-1
500
0.4
500
200
10
350
350
100
300
3000 3
4000 4 5 1
6000
8000 10000 10 4 5 10
15000 20000 15 20 20
30000 40000 30 40 70
3000
4000 3
4 1
6000 5
8000 10000
15000 20000 10 15 10 20
30000 40000 20 30 30 40 50 70
V(m /h)
3
pd (mm H2O)
30 40 50
4 5
BOX FANS | 13
Pa (N/m2)
25-25
6.0 5.0 4.0
Not usable NO UTILIZABLE Not recommended UTILIZABLE SEGUN SERIE NO RECOMENDADO Not recommended
8.0
65%
68%
64%
1200
54%
900
67% 13
69%
66%
54%
11 .5
3.0
800
2.0 1.5
700
500 400
2.0 1.5
pt (mm H2O)
Pa (N/m )
20
0.6
1.0
20
200
0.8 0.6
in
350
-1
in
10
350
n (m
0.4
100 10 250
300 100
300
Not usable NO UTILIZABLE UTILIZABLE SEGUN SERIE Not recommended NO RECOMENDADO Not recommended
2000 C2 (m/s) pd (mm H2O) 3000 2 4000 6000 4 1 8000 10000 5 2 3 15000 20000 30000 40000 10 15 20 4 5 10 20 30 40 50 V(m /h)
3
4 1
10000 5 2
15000 20000 10 3 4 5
30000 40000 15 20 10 20
n (m
0.4
60000 30 30 40 50
80000 100000 40 70
V(m /h)
3
30-28
120 110 100 90 80 70 60 50 40
73%
15 78%
75%
67%
1200 1000 600 550 900 800 700 600 500 400
(kW
PA
2.0 1.5
350
pt (mm H2O)
30
300
1.0
20
300
0.8
250
200
n (m
0.6
in
-1
10
200
100
Not usable NO UTILIZABLE UTILIZABLE SEGUN SERIE Not recommended NO RECOMENDADO Not recommended
5000 C2 (m/s) 2 pd (mm H2O) 10000 3 4 1 15000 20000 5 2 3 30000 10 4 5 40000 15 10 60000 20 20
3 80000 100000 V(m /h) 30 40
30 40 50
70
14 | BOX FANS
Pa (N/m2)
Note: All these fan curve are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point.
Pa (N/m )
2
0.8
pt (mm H2O)
(kW
30
1.0
600
300
2
30
PA
PA
100
75
50
25
BOX FANS | 15
E6 (1100W)
E6 (525W) E6 (237W)
E6 (525W) E6 (765W)
E6 (237W) E6 (525W)
E6 (525W)
E6 (1100W)
E6 (765W)
16 | BOX FANS
Accessories
Roof, inlet hood, power switch, pressure switch, filter, double skin panels.
BOX FANS | 17
Airflow
Side view
Top view
18 | BOX FANS
KPB
Belt driven box fan for inline or 90 operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and the impellers outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50C
KPB Duo
Belt driven twin fan for inline operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and the impellers outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50C.
KVB
Belt driven box fan for inline operation and suitable for outdoor installations fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of 1 mm thick galvanized steel. The impeller and motor shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots, the impellers outlet connected with the casing through a 18 mm thick rubber joint. An IP 55 connection box is fitted on the casing for easy installation. Maximum temperature of the transported air: 50C
KPD
Direct driven fan for inline operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 54 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and its outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50C.
KPD Duo
Direct driven fan for inline operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 54 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and its outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50C.
BOX FANS | 19