You are on page 1of 10

USER'S MANUAL

SWING GATE OPENER SW2OO SERIES

1.50m max 'l00kg max

1.50m max 100k9 max.

lmportantSafetyAdvice:
regulations is required. of therelevant electrotechnical 1. Knowledge is necessary. in useandmaintenance of safety equipments 2. Training laymains andconJrol cables separately. 3.Always before initial operation. 4. Test every equipment before initial operation. familiar withtheuseof thesystem 5. Make

Content of the Kit:


't.,

Part A Actuator

. I

x2
'

,ii,,
PartB '1,",. ;]'x2

:3 pu.t

Remote Control control Box

{:-. *z
(The shorter one / on the gate )

(The lohger one / on the pillars)

x2

\ \\ \, \3 Battery Wire

Warning Light

xl

ft

v.2

Wiring Diagram:
Garden Lamp

Warnino Liqht

Control Box

1Scm
Photocell
" / \

Photocell

-l-

lnstruction of lnstallation!
1. Keepa spaceof smm(default from setting factory) between thedriving boltandthe metalcoverof the motor. 2. Measure outthe length of E on the figurelas 36cmor 37.5cm. Usethis point point as a center forfixing the T form metal(PartB) on the gate. Drill two holes on the gateto fixthe PartB (theshorterT form metal).

i"&*
Copyright@

SW 2OO

Version 1.O

Page -l

Distances: Installation Recommended


ODen RaDge

90"
100'

15.5cm 36.0cm 14.0cm 37.5cm

end,Part theAxisfor the motor 3.Assembly the bolt together and

ontoPartB on the 4. PuttheActuator withthe gate. lvlove PartC together on to pillartomakesurethe Actuator "late closed. is complete

. _n

point linefromthecenter 5. Drawa horizontal of the PartB. Stickthe PartC on thepillar holes. Fixthe twosupposed anddrilllhe PartC on the pillar.

on to the PartB andC. 6.1 Fit theactuator into oftheactuator screw 6.2 Fittherelease the sth holeon PartB and C.

sw 20o

vercion {.o

Page -2 -

Diagram Connection
Thermal Fuse

2 3 0V A C i n

230VAC out for GardenLamp

12 VDCinputfrom mainPCB

Totransformer 12VAC

To Backu Batte

( 1 2 vD C )

s
Dip Switches

LL

Coloriru[ggtlgl for motor wire!


Black wire for ' Red wire for +

t2v Dc

Antenna
Gfound

oa PHOTOCELL
SENDER

PHOIOCELL
RECEIVER

Toexternal open/close switch Toexternal GardenLampswitch Forexternal LEDdisDla Garden LamD lvlanual Button o n/closel\4anual Button 12V DC outout to small PCB

@Q\
N

sw 200

Version 't,O

Page -3-

Transformer

AC Wiring : lnside of the control box,thewiring should be likethe photo on the left.

Opening / Closing Learning:


proceed Please thisfunction before using this product, otherwise thesystem willdrive gates gate the improperly. E.g.: The can't close completely or can'topen to theintended with somestrokelengthleft unused, degree " Auto" press Toactivate thisfunction, button onthePCB for3 seconds while thePCBis on. 'Auto" release the button, it willenter theopening/closing learning After mode as below: 1.Thesystem willclose first. thegates possibly Auto Please remove anyobstacle could block thegate. Befo!'e theactuators statl,thewarning light willblink for 3 seconds. Then Actuator 2 willclose first,andthen Actuator close1 second later. Actuator 1 willopen thegate1 fully, 2.After 3 seconds, gate2 fully. waiting for3 seconds, Actuaior 2 willopen theothef 3.After 3 seconds Actuator 2 willclose fulyfirct, waiting for3 seconds, Actuatof 1 willclose fully. 4. System repeats theactions of point 2 and3 onemore time. 3 seconds, system checks operaiion ofActuator 1 andActuator 2 together. 5.Afler process learning succeeded. thesystem is ready foruse. 6.Afier lfthe system blinks afterthis learning mode, which means learning invain, please make sure thatthere's noobstacle ontheway, then tryagain toVigger thelearning mode.

copyright@

SW 2O0

Version l.O

Page -4 -

(activation Remote Learning of remotecontrolfor gateand lampoperation):


pleaseproceed Toaciivate the remotecontrol service, the following steps:

(forOpen/Close A. RFgate learning: thecales) "RF" '1. keyonthePCB forover 2 seconds Press while thePCB is on. 2.You'llsee theLEDlight on (leafning mode entered) please press anykeyontheremoie control, (learning LED willnowblink for3 iimes succeeded) without or light offafter 10seconds blinking please process). (learning failed, tryagain thewhole re0eat 1 and2 to activate 3. Please thesteD another control. remote remote otherwise theunlearnt controlwon't be recognized bythesystem. B. RFlamplearning;(for Turning On/Off theGarden Lamp) "RF wilh keyonthePCB Proced lamp" andanother keyontheremote conirol 1-3 above. asstep

Note:Upto I different RFremote control keyscanbe learnt for eachfunction by thissystem(gates & Garden Lamp).

Remote Control:
Choosetwo of the four keysto proceed RF learning. The rest of the keysare available for otherpurposes such as GarageDoorOpener.

Theremote control has4 keyson it,andchoose twoof themto proceed RF learning for gatecontrol andlamp one-key control separately.

(open, closeandstop)by remote Operation control:


is very simple;one key presswill openthe gate,nextpressto stop,nextto The renrote operation close thegate. nextto stop...and so on. gates: Whenopeningthe lightwill for 3 seconds, 1. Warning blink thenActuator 1 opens,4seconds later theActuator 2 opens. 2. lfthe gatehitssomething, Actuators revefse for 3 seconds warning blinks untilnextcommand Jighl recetved. Whenclosingthe gates: light willblink for 3 seconds, 1.Warning thenActuator 2 closes, 4 seconds later theActuator 1 closes. Actuators 2. lf thegatehitssomething, reverse for 3 seconds warning lightblinks untilnextcommand recetved.

Simply switch on andoffthelamp bythekeywhich hadproceeded the"RFlamp" learning. gateoperation Remark:The worksproperly onlyaftersucessful Opening/Closing Learning,
copyright@

(onandoff)by remote Lampcontrol control:

sW 20o

Version1.0

Page.5.

(Optional): Photocell '1. During Opening:


system will; hasbeenintercepted, When theloopof photocells OR 2 hasbeen activated. if theActuator A. ignore, yel. 2 hasn't been activated if the Actuator B. halt, Closing; 2. During system willstopclosing thegates andthen hasbeen intefcepted, of photocells When theloop gates until thesetposilion. simultaneously open both

Autoclose:
(only is enabled, depends onyour setting of later when thisfunction or 60seconds 30seconds Actuator 2 closes, 4 seconds later light \^/ill blink fof3 seconds then warning key1 ofdipswitch), '1closes. off. finished, warning light willbe swiiched When theprocess Actuator

gates control on the PCB: Manual

to stop,nextto onekeypress willopenthegate,nextpress is thesameas remote: 1.The operation gate, on. next io stop...and so the close to O/C& GND terminals) wallbutton is available.(Connected handset or external 2.Optional

lamp on: Manual


on andoffthe lampby the Simply switch

"[,4anual lampon" key.

"Clear" whilethe PCBis on. keyon the PCBfof over2 seconds Press hasbeencleared. for 2.5seconds thenthe RF memory You'll seethe LEDblinking "Cleai'keyfor over2 seconds. power; keeppressing keyon the PCBandinputAC Press"Clear" andlighton for 3 seconds thenlightoff. for 2 seconds You'll seetheLEDblink out,all RF datawillbe cleared. actions havebeencarried Oncethe mentioned

Clear RFmemory: Reset;

Q u i c kr e l e a s e : screw Loosen therelease

copyright@

SW 200

Version 1.0

Pag6 '6 -

Settings of Dip Switches:


ON

setting of dipswitches. The default

g! KKK I KNX K= nnI ! ! !


2 3
5l

1l 8l

Function Kev No. 1 Auto-Close 2 Auto-Close Timer 3 Gate Type 4-8 CurrentLimit

ON

Yes 60 Sec HeavyGate selected

OFF No 30 Sec LightGate unselected

Iimitvalues for different dip switchsetting: Approx. current


4 switch5 slvitch 6 srvitch 7 switch8 srvitch 4.5A' l.0A 2.04 3.0A A l to{f

5.2A

ON

E#trNEi

nEnnnEEl '" " r z r i-'1.''6-'"i--ii

(means l\,4aximum Limit theworst Current also please sensibility, could shorten thelifeof motor, try lowercurrent limitfirst)

ON

[lt'ErEEi tEE[[E[i '.i--j--i-i---s L : :

Highest Current Limit Second

ON

E X[[ t t f ; i
r 2 1 1 5 6

Enixtrnq[j
? 8
1 2 1 4 5 6 7 E

Limit l/linimum Curfent

ON

IKXU&EKE: =EEI'X,UXEXXI

When,user switches several switches on, for safetyreason, system will choose the lowest (switch 4instead 6 or B)current limit of switch setting automatically.

copyright@

sw 200

Version 1.O

Page -7 .

Optional Accessories:
I

o
tt E

o
6

o tr
o

I Set of Photocell

of Photocell: ODeration
whefe thesender andreceiver canbe along thesameline :-:--==-: a proper installation site, Seleci to theopeneis PCBaswiring diagram above. height. Connect andatthesame pfoperly by interruptting the lR between try andseeif it works Power onthesystem, inthereceiver should respond accordingly andreceiver fortimes. Therelay thesender while LED switches ONandOFF. photocell dudng opening ihegates, thegates willignore wellinstalled, while it'striggered \\'ith willfevefse !\hileit'striggered during closing thegales, thegates fof theinte|ruption andopen. light willkeep blinking untill next command sent . 3 seconds andstop andwarming

Specifications:
[/]odel Power Supply Power for l\,4otor Gate Wejght I\ilaximum GateWdth l It4aximum Length Stroke
Dfive i l ill

'l10V AC110% 50Hz: AC60Hz 230V available


1 2\ / n a

OVVZUU

.,'rl'

Time 90"Operating Range Open Duty Cycle

100+100KGS) 2 0 0 K G(S '1.slVI - 1.5[I {1oFeet) 13in) 3 3 0 m( m E a r o u n1 d5S e c 20"/" -20-65"C


Yes

Teml Operation
Protection Ovefload

l,t

.Backup Recharging Batter)l.f.:9!rlldgJ!i AutoGateClose , . . . , : :, nal,, .:


RFCariage ControlRange
't,rl

AH) Yes( NolIncluding Battery 12V.7

(off/ Adjustable timer 30/60sec) 'arning Light / Photocell/ Back-up Battery


315lVHz/433.92 N,4Hz Approx.30-50 l\leters

copyright@

SW 2O0

Version 1.0

Page -8-

You might also like