1320 CT REQUIRMENT
This section describes the recommended minimum HW/SW requirements of the ECT application for a recognized level of application performances
Windows versions
.Windows 2000 till sp4 included
.Windows XP professional Edition (till sp2 included). It is mandatory to de-active the firewall installed
Additional requirements
.Netscape communicator or Ms Internet Explorer 4.x or higher .Java 2 Run time Environment versions from 1.4.2-12
NOTE: Each specific Java version could require minimal Windows sp installation
1320 CT Setup
PRESS RUN
10
After lower layer you must add alcatel lower layer network card From control panel add new hard ware then press next
11
12
13
14
15
16
17
18
Disable firewall
19
20
Alcatel 9400 AWY version 2.0.4 Software Before access on the microwave you should have the 9 pin cable RS 232 as shown to be plugged on the ECT in the microwave IDU
21
Alcatel 9400 AWY version 2.0.4 Software Open the software, right click to start the supervision on the microwave as shown below
22
After you started supervision, the lct gives you the name of the microwave link, then
You begin to show equipment as shown below
23
Alcatel 9400 AWY version 2.0.4 Software After you select show equipment , you will enter the application username and password which are 1-user name : initial as shown below 2-password:initialing
24
1- configuration
2- Diagnosis
3-supervision
4-sw download
25
1)configuration: this tab includes the following:1.1-NE Time 1.4-system settings 1.2-Network configuration 1.5-Quick Configuration 1.3-Alarm Severities 1.6-Profile management
26
1.1)NE Time:The NE Time box displays the current NE time and OS time as shown below.
27
1.2)Network Configuration: this configuration allows to perform the following operations as:- 1.2.1)local configuration 1.2.2)NTP configuration 1.2.3)Ethernet configuration 1.2.4) IP configuration 1.2.5)Quick Configuration
28
29
1.2.2)NTP Configuration:This Configuration allows to enable/disable the network time protocol as shown below.
30
1.2.3)Ethernet Configuration:this configuration allows to define the parameters necessary for the Ethernet interface as shown below.
31
32
1.2.4.1) IP static routing configuration:This menu defines the host destination address for IP static routing configuration for the NMS Channels Used
33
1.2.4.2) OSPF Area Configuration: This menu defines the open shortest path first address which gives a synthetical information that includes all the addresses specific to NE in an Area (NMS ,Ethernet) features
34
1.2.4.3) IP Point to Point Configuration :This menu allows to Enable or Disable the three NMS Channel which use the ppp protocol .
35
36
1.3) Alarm Severities:the alarm severities is divided into four profiles:1-NO Alarms: within this profiles all alarms are disabled 2-Primary alarms : This profile enable the emission of the primary alarms within the Major, Minor and warning alarm severity 3-NO Remote Alarms 4-All Alarms: This profile enables the emission of all the alarms on the microwave
37
38
1.4) System Settings:This Menu allows the system configuration , providing the setting of all parameters for the NE setup.
39
40
1.5) Quick Configuration:- This is a very important menu that contains all
configurations for this microwave link, this configuration will be saved on a flash memory stored at the back of the IDU ,This menu is used in case of commissioning the microwave with anew flash card (Data entry for the IDU), we have 2 types of Quick Configuration 1- by interactive mode 2-by text file
1- by interactive mode:-This procedure allows a full system configuration through a guided process. The related windows will be displayed by a wizard tool to enter the link configuration (manual configuration) 2- by text mode:- This procedure allows the user to load a NE configuration from a structured XML file , the text file will ask the user to choose a configuration file through a file browser ,then the user select his own configuration (Automatic configuration).
41
Alcatel 9400 AWY version 2.0.4 Software 1.5.1) Quick Configuration by interactive mode steps:1st step :- let us make configuration of non protected 1+0 link
42
Alcatel 9400 AWY version 2.0.4 Software 1st step in case of 1+1 HSB
43
Alcatel 9400 AWY version 2.0.4 Software 2nd step :- this wizard allows to choose the tributary configuration and the signal mode status should be selected to be unframed, in case you disabled it ,you will find no transmission alarms for the free ports in the NE , but you should select the unframed signal mode to use all ports
44
Alcatel 9400 AWY version 2.0.4 Software 3rd step in case of 1+0 non protected link :-This menu allows you to define the basic parameters for each configured channel as TX power(transmitted power), TX , RX frequencies and the shifter
.
45
46
Alcatel 9400 AWY version 2.0.4 Software 4th step:- This menu allows to configure one or more 3 OSPF Areas (3 Areas max)
47
Alcatel 9400 AWY version 2.0.4 Software 5th step(protection schemes ):This step exists in configuring 1+1 HSB protected link. 1+1 HSB = 2 ODUS with the same frequency, 2 IDUS (for backup MUX/DEMUX), and 2 IF cables
48
Alcatel 9400 AWY version 2.0.4 Software 5th step(protection schemes ):Revertive & Non Revertive: Suppose that we have 1+1 link, and we have failure in the main unit, then the
extension unit is the active one and responsible for transmission and reception
from the other site.
If you take the corrective action for the main unit and it is now ready to carry traffic and will be responsible for transmission and reception from the other site, then if it is automatically carries the traffic then this operation type is Revertive
but if you activated the main unit to carry traffic manually, then the operation type will be Non Revertive
49
Alcatel 9400 AWY version 2.0.4 Software 6th step:- This menu allows to enter the local IP address, and to Enable or Disable the Ethernet configuration in case there is Ethernet Interface (optional).
50
Alcatel 9400 AWY version 2.0.4 Software 7th step:- This menu allows to configure the IP point to point interface (RF, V11,G703 )interfaces.
51
Alcatel 9400 AWY version 2.0.4 Software 8th step:- This menu allows to complete the IP configuration(static Routing configuration),
52
Alcatel 9400 AWY version 2.0.4 Software 9th step:- This menu allows to configure the Auxiliary interface and EOW through the order wire configuration and the auxiliary interface configuration
53
Alcatel 9400 AWY version 2.0.4 Software 10th step:- This menu allows to complete the external point configuration. In case you connect the site external alarms to the microwave as Power, door, ACS, high temp alarm instead of connecting this alarms to the bts
54
Alcatel 9400 AWY version 2.0.4 Software Last step:- This menu summarizes all the parameters configured during this procedure and some relevant parameters with default values.
55
1.6)profile management:This menu allows to change the username and the password of the software used and to control the users (restricted).
56
Alcatel 9400 AWY version 2.0.4 Software 2) Diagnosis:In this menu we have six options which are available as shown
2.1-Alarms
2.2-Log Browsing
2.3-Remote Inventory
57
2.1)Alarms:This menu allows the management of the NE alarms(their type severities). We can open the NE alarms as shown below
58
the next table will describe an example of NE alarms including their types, severity and the time of the alarm , and if this alarm cleared or not.
59
60
Alcatel 9400 AWY version 2.0.4 Software 2.2) Log Browsing:This menu is Divided into 2 submenus which are 2.2.1)Alarm Log Display 2.2.2)Event log Display 2-Alarm log Display: Display all the alarms stored in the NE including full alarm data (type, severity ,time). 1- Event log display : The Event Log window analyze all the events stored in the NE.
Note that This menu is very important in case of the unstable links as you can open this menu to determine All the alarms and events stored in the NE ,hence you can take your corrective action to clear your alarms and the link will be stable again.
61
Alcatel 9400 AWY version 2.0.4 Software How to open The Log Browsing menu?
62
Alcatel 9400 AWY version 2.0.4 Software 2.2.1) Alarm log Display Menu
From this window we can display all the alarm data (time, type of alarm) Also you can filter any type of alarms you want to display it , you can filter the major, minor and critical alarms .
63
2.2.1) Alarm Log Display:After we select Filter , we will wait for downloading the alarm report as shown below.
64
Alcatel 9400 AWY version 2.0.4 Software 2.2.1 Alarm Log Display:Then we will see the alarm report , we can save this report as PDF file, XML File.
65
2.2.2) Event Log Display:This menu analyze all the events stored in the NE. The Event report is shown below.
66
2.3) Remote Inventory:This menu shows all the information on the equipment as part number serial number This menu helps you incase the link is down, and the site contains many microwaves and you want to identify your microwave link from this many Dishes, you can use the remote inventory to identify the serial Number of the ODU , then you begin to take the corrective action. Remote inventory is opened as shown below:
67
68
2.4) Abnormal condition list:This menu displays the abnormal conditions made manually as:1- TX muting 2-Loopback 3- switching commands (forced,lockout) The abnormal condition list opened as shown below
69
2.4) Abnormal condition list:After you click on the abnormal condition list . suppose that we Make a loopback, this will give an abnormal condition as shown below.
70
2.5) Summary Block Diagram View:This menu displays the alarms and the status present on link from the 2 sites as loopbacks, switching and alarms in the IDU and ODU. The summary Block Diagram View depends on the configuration if it is 1) 1+0 2 )1+1 HST (2IDU, 2ODU,2 IF cable and same frequency) The summary block Diagram is opened as follow.
71
Alcatel 9400 AWY version 2.0.4 Software 2.5) Summary Block Diagram View:For The 1+0 Configuration, The block diagram will be as follow:-
72
2.5) Summary Block Diagram View:For The 1+1 HSB Configuration, The block diagram will be as follow:IDU loop of ch 1 tributary loop of ch 1 ODU loop of ch 1
RF loop of ch 0
73
2.6) Current Configuration View:This menu shows the current configuration of the NE ( read only file), you can save this file on your laptop in case you make data collection for microwaves on site , this will help you in case this link is down because you saved the configuration file on your laptop before. we can open current configuration view as shown below.
74
2.6) Current Configuration View:after you click on the current configuration view , you will receive the following file.
75
Alcatel 9400 AWY version 2.0.4 Software 3) Supervision:This tab is responsible for the supervision and management system within the NMS interfaces ; this menu is divided into four submenus as:-
3.1)Access State
3.2)Restart NE
3.4)SW key
3.3)MIB Management
76
3.1) Access state:This menu allows or inhibit NE craft access , this menu is divided into 2 submenus which are 1)OS 2)Requested
1)OS : access denied, this means that OS only manages the NE and can make changes in the link configuration ,as the craft terminal can read only the NE configuration without modification in it
2)Request: This menu is to inform that the craft terminal can also manage the NE operations and configuration with the OS
Note that:In case you go to the site and you want to change something in the configuration as raising TX power for example, but you find that you cannot make this action , this means that access denied or the access state in the OS then select the access state to be requested or call the NMS server to allow your access, Other solution:- You can remove the NMS Cabling , and then Reset the IDU, then you can take your actions, then put the NMS cables again to be managed again
77
78
3.1)Access state:
In case the access state is requested.
79
3.2)Restart NE:This menu allows a software reset for the NE ,also it can be executed without affecting the traffic. this menu can be opened as shown below.
80
3.2)Restart NE:from the previous slide , when you click on restart NE the following message appears as shown , then you select yes
81
3.3)MIB Management (Management Information Base):The MIB Management includes all the system configuration data, except the routing configuration data as IP Configuration ,NTP Server Configuration
3.3.1)Back up
3.3.2)Restore
3.3.3)Remove file
3.3.4)Activate
82
3.3.1)Back up:This menu allows to save on the craft terminal the NE Configuration
after step 3 The new file 1+1 configuration 16 E1 will appear here
Step 1 The file name will include your back up file you want to create as 1+1configuration 16 E1, then the confirm back up tab will be active
Step 3 Press the Refresh button and the new back up file will appear
83
3.3.2)Restore:This menu allows to download the previously created backup file to the NE
Here we should have the new file 1+1 configuration,16E1 , and confirm Restore is active
After confirm Restore is active, press on it to start downloading the previously created backup file to the NE
84
3.3.3)Remove file:This menu allows to remove the file, You just downloaded in the previous step
85
Alcatel 9400 AWY version 2.0.4 Software 3.3.4) Activate :This menu allows to activate the configuration just down loaded in the restore file menu (2nd step)
86
3.4)SW key:This menu reads the information about the key plugged into the main IDU The SW key menu can be opened as follow:-
87
4)SW Download:This menu contains the flash card software status and versions installed in this flash cards.
This menu is divided into 3 submenus which are:1)Server Access Configuration 3)SW Status 2)Init SW download
88
4.1)Server access configuration:This server used to speed up the software downloaded to the NE. Server access configuration can be opened as shown below.
89
4.1)Server access configuration:When press on server access configuration from the previous slide, then this menu appears
90
4.3) Software status:This menu allows to display the information of the software installed in the we can install 2 software versions in the NE as shown below.
2 software version are installed
Committed means that this software version is currently in use
91
92
93
Alcatel 9400 AWY version 2.0.4 Software After introducing the equipment configuration, supervision we are going to describe the Equipment hardware itself through the equipment menu Equipment:-
This menu describes the microwave hardware , alarms , configuration and remote inventory
We can open this menu as shown below (Equipment of 1+0 link)
94
95
Equipment menu (alarms tabe):The alarm menu indicates the alarms exists on the microwave hardware (IDU and ODU) , we have a coloured ball exists on the IDU and ODU known to indicate the status of the IDU and the ODU This colour differs indicates the severity of the alarms as follow: Green :No alarms Cyan : Warning alarm active Yellow : Minor alarm active Brown: Major alarm active Red: Critical alarm active
96
97
98
Equipment menu (Configuration tabe):This tabe indicates the alarms profile for the selected node, also you can change this alarm profile from this menu
99
Alcatel 9400 AWY version 2.0.4 Software Equipment (Configuration tab):IN case of 1+1 HSB .
100
Equipment menu (Remote Inventory tab):This menu includes all information about the equipment as part no, serial no ,company identifier, this menu can be opened as shown below
101
102
Alcatel 9400 AWY version 2.0.4 Software External points menu:This menu is necessary in case you connected the site external alarms as (power, high temperature alarm, rectifier alarm, Fire alarm, Door alarm and
103
External points menu (Input tabe):This menu can be opened as shown below
104
External points menu (Output tabe):This menu can be opened as shown below
105
Line Interface:This menu allows the user to manage the PDH NMS Interfaces and the tributary ports interface, This menu is divided into :1) NMS Interface 2) Tributaries Interface Line interface menu can be opened as shown below
106
Alcatel 9400 AWY version 2.0.4 Software Line Interface (NMS Interface tab):This menu includes the supervision NMS Interfaces, Alarms of this interfaces and the alarm profiles, you can change the severities of alarm profiles
107
Line Interface (Tributary Interface tab):This tab gives information related to the tributaries as: Interface type(E1,E3) Port number Channel number in case of 1+0 and 1+1 HSB configuration Rate/Modulation : bit rate of the tributary Signal Mode: indicates type of frame (unframed/framed/disable)
Line RAI insertion: refers to insertion of the RAI(remote alarm indication)signal in TX side.
Radio RAI Insertion : refers to insertion of the RAI signal in RX side. Alarm profile : indicates the severity of the alarm( primary alarm)
108
Alcatel 9400 AWY version 2.0.4 Software Line Interface (Tributary Interface tab):The tributary Interface tab can be opened as shown below
109
Alcatel 9400 AWY version 2.0.4 Software performance:This menu allows the user to activate and monitor the performance monitoring process which gives indication on the quality of service , the performance menu can be opened as shown below
110
Alcatel 9400 AWY version 2.0.4 Software Performance (threshold table):This tab shows how to see or change the threshold values assigned to performance monitoring counters
4)Unavailable seconds:UAS
also we have 2 types of performance monitoring 15 min & 24 hr for both types of threshold tables (hop and link)
111
1)Performance (threshold table Hop ):from the threshold menu you can create the threshold value assigned to pm counters (ES,SES,BBE) as shown below
112
1)Performance (threshold table Hop ):as we can see in the picture below you can change the threshold values assigned to PM (performance monitoring) counters
113
Alcatel 9400 AWY version 2.0.4 Software 1)performance (hop tab):we have 2 types of performance monitoring 1)15 min performance monitoring 2)24 h performance monitoring
also we have 2 types of reports for threshold hop 1)CD: current data report
2)HD: history data report for each type of performance you will have the 2 types of reporting (CD & HD)
114
performance (hop tab):In case of 15 min performance monitoring the current data (CD) will be opened as shown below
115
performance (hop tab):In case of 15 min performance monitoring the History data (HD) will be opened as shown below
116
performance (hop tab):In case of 24hr pm, current data report will be shown as below
117
performance (hop tab):In case of 24hr pm, History log report will be shown as below
118
2) performance (threshold table link):This type of threshold table appears only in 1+1 HSB configuration, from the threshold menu you can create the threshold value assigned to pm counters (ES,SES,BBE) as shown below , the threshold table link menu can be opened as shown below
You can create the threshold low and high values through this menu
119
Alcatel 9400 AWY version 2.0.4 Software 2) performance (threshold table link):the 2 types of performance monitoring (15 min, 24hr ) , we have 2 types of reports (CD & HD), CD: is the current data report taken for both pm( 15 min, 24 hr)
in the picture below , we can observe the current data report CD within 15 min pm
120
Alcatel 9400 AWY version 2.0.4 Software 2) performance (threshold table link):In case of 24hr pm, History log HD report will be shown as below
121
Alcatel 9400 AWY version 2.0.4 Software Radio:This menu allows the user to manage the resources of the radio transmission channels (channel no, modulation type, TX and RX frequencies, TX power and
ATPC).
This menu contains 5 tab panels which are :1)alarms :shows active alarms 2) Configuration: configure some radio parameters
122
Radio:For 1+0 configuration : we have channel 1 only For 1+1 configuration : we have cannel 1 (main unit) and channel 0 (extension unit) Radio menu for 1+0 non protected link can be opened as follow
123
Radio:For 1+1 configuration : we have cannel 1 (main unit) and channel 0 (extension unit)
124
Radio (Alarms tab):This tab includes the fault management and the active alarms on the microwave, same menu in 1+1 HSB Configuration , Its menu can be opened as shown below.
125
This menu includes information related to the transmitter status through the TX Mute function , this menu can be opened as follows.
126
Radio (frequency tab):This tab can be opened as shown below (explaining this tab at next slide) same menu will be opened in 1+1 HSB Configuration
127
Alcatel 9400 AWY version 2.0.4 Software Radio (frequency tab): This menu indicates the TX and RX frequency , also it describes the shifter
Shifter = TX frequency- RX frequency
Shifters are variable according to the operating frequency , the table below shows frequency and the related shifter.
TX Frequency range: is the range of frequency written on the ODU unit, in case you have a faulty ODU unit and you need to change it, the new ODU should be Within this range
25 GHZ 38 GHZ
8 GHZ
128
Alcatel 9400 AWY version 2.0.4 Software Radio (RTPC & ATPC tab):This menu allows to read and set the TX power parameters. ATPC means automatic transmitted power control, RTPC means range transmitted power control. same menu will be opened in 1+1 HSB Configure
129
Radio (Power Measurement tab):This menu allows to read the Power level (TX & RX) for the local and the Remote stations , This menu can be opened as follows
130
Alcatel 9400 AWY version 2.0.4 Software Radio (Power Measurement tab)for 1+0 non protected link:After you press start , you will find a graphical representation for the TX & RX levels for both local and remote site, then click on show details to have a table indicating these levels with their maximum , minimum and current states
TX local end :transmitted power at your site TX far end: transmitted power from the remote site RX local end : received power at your site RX far end : received power at remote site
131
Alcatel 9400 AWY version 2.0.4 Software Radio (Power Measurement tab)for 1+1 HSB protected link:for the 1+1 HSB protected link, we have 2 channels:channel 1 for main unit and channel 0 for extension unit, the two units are connected together through b2b connection within the IDUS(MUX/DEMUX)protection and coupler within the ODU this coupler makes a difference of 10 db between the main and the extension units
Note that:IF the extension unit is acting as the active unit for site A in the HST TX protection, then the main and extension unit at the other site(site B) will have received level decreased by 10 db rather than the main unit is the active unit transmission in site A .
132
Alcatel 9400 AWY version 2.0.4 Software Radio (Power Measurement tab)for 1+1 HSB protected link:TX is stand by in ch0 for both local & far ends
133
Radio (Power Measurement tab):How to read a power measurement file? Suppose that you have an unstable link , and you want to determine the power level variation ,then you should follow this steps:1- click on Read File , then press select file as shown
134
135
Radio (Power Measurement tab):step 3: A WordPad file of the TX & RX levels appears as shown below.
136
Protection schemes:This Menu displayed only in protected 1+1 HSB microwave links for managing the switching between ch1 & ch0, the protection schemes menu can be opened as
137
Alcatel 9400 AWY version 2.0.4 Software Protection schemes:The protection schemes menu is divided into 3 main tabs which are:1)Mux/ Demux
Mux protection
2)HST TX protection
3) Radio Protection.
HST TX PROTECTION
dDemux protection
Radio protection
138
Alcatel 9400 AWY version 2.0.4 Software Protection schemes:1)Mux/ Demux protection: protection in TX/RX side towards the IDU Mux protection in TX SIDE, Demux protection in RX side
139
Alcatel 9400 AWY version 2.0.4 Software Protection schemes:for the 3 schemes , there is a list of commands you should know for modification the state of switching between the main and extension units
1) Lockout : this commands equals to switching off the unit, suppose that you apply lock
out command on the extension unit , then if the main unit became faulty , then the link will be down no protection available due to locking out command of ch0 , Gives abnormal condition indication, lock out command is available for the standby unit 2)Forced :to force the protection on one unit only, suppose that the main unit suffers from HIGH BER then you can force the protection to the extension unit , then if you take the corrective action for the main unit and HIGH BER alarm cleared, the extension unit still the active unit due to the forced command , Gives abnormal condition indication, forced command is available for the active unit, active unit ch1+forced command= spare unit ch1
140
Alcatel 9400 AWY version 2.0.4 Software Protection schemes (Mux/Demux protection):Main unit is active and the extension unit its backup for protecting Mux/Demux Automatic switching normal condition
141
142
Alcatel 9400 AWY version 2.0.4 Software Protection schemes (Mux/Demux protection):in case of forced command
143
Alcatel 9400 AWY version 2.0.4 Software Protection schemes (HST TX):Main unit is the active unit which means main ODU only transmits to the other site , but the extension unit is stand by
Automatic restoration
144
Protection schemes (HST TX):In case of lock out command : lock out command is available for the standby channel only i.e ch0
145
Protection schemes (HST TX):In case of forced command: the forced command is available only for the active unit i.e ch1
Forced command is available for the active channel, to force the transmission on stand by ODU ch0 Select Forced and then press apply
146
Protection schemes (HST TX):In case of forced command: the forced command is available only for the active unit then the main unit will be the spare unit as we can see that in the previous slide, the main unit ch1 was active but when applying forced command it became the spare unit as shown below
147
Protection schemes (HST TX):from the previous slide, we can observe that the main unit ch1 became the stand by after applying the forced command on it, the table below shows
the power measurement for ch1 after applying the forced command
No TX power for the local end due to forced command indicating abnormal condition
RX local end still -53 coz ch1 at remote site is the active unit
RX far end became 63 because the extension unit ch0 is the active unit in transmission and there is -10 db difference between ch1 & ch0
148
Alcatel 9400 AWY version 2.0.4 Software Protection schemes (Radio protection):Radio protection means receiver protection ,it includes 3 main tabs 1)Alarms 2)protection scheme parameters 3)RX static delay
Automatic normal condition :main unit is active and extension unit is spare
149
Alcatel 9400 AWY version 2.0.4 Software Protection schemes (Radio protection):1)Alarms:The most common alarm observed on the radio protection is Loss of alignment
this alarm takes place in case there is failure any unit (main unit or extension)unit this means that there is no radio protection and there will be receiver delay because the other unit is faulty, to solve this problem
take the corrective action towards the faulty unit so that the link became 1+1 protected link and then activate the hitless switch radio protection by aligning the RX static delay through the automatic operation next slide shows how to clear the Loss of alignment through the RX static delay
150
Protection schemes (Radio protection):3)RX static delay menu can be opened as shown below.
To clear the loss of alignment alarm click on RX static delay tab and press align to activate the automatic operation for the hitless switch
151
Protection schemes (Radio protection):the switching commands are available for the Radio protection:1)Lock out: lock out command is available for the standby unit, an abnormal condition appears when lock out command is active.
2)forced command: forced command is available for the active unit to change it to the standby, an abnormal condition appears when forced command is active
3)Automatic switching (None): is the normal switching condition switching commands are well explained in slide 140.
152
Protection schemes (Radio protection):IN case of lock out command, you will have this menu:-
153
Protection schemes (Radio protection):IN case of automatic switching None command is used to remove the lock out command in the previous slide , select None and then you will have this menu
154
Loopback:You can use this menu to do the following:1)IF you have communication alarm between the 2 sites as High BER, demodulator fail, modulator fail , RX fail you can use the RF loop back to decide weather the fault is on your local site or from the remote site such that IF you make RF loop and the alarms cleared and you have normal received level then the problem will be on the other site 2)IF you have transmission alarm as AIS for a tributary carries a bts, and this bts suffers from AIS, you can use tributary loopback to check the route
155
Alcatel 9400 AWY version 2.0.4 Software Loopback: WE have 6 types of loopbacks in both 1+0 configuration and 1+1 HSB configuration:1)RF loopback: is to check the total path including( IDU, IDU CONNECTOR, IF CABLE,ODU CONNECTOR, ODU) 2)ODU loopback: to check the path before ODU including (IDU,IDU CONNECTOR, IF CABLE, ODU CONNECTOR) 3) IDU loopback: to check the IDU equipment NOTE that :in case you activate any loop of the previous 3 loopbacks : the link will be down and you will effect traffic. 4)tributary loopback (E1-TX port x NE): input loop back at the tributary 5) tributary loopback (E1-RX port x NE): loopback towards the remote station at a tributary , but this loopback is not available. 6)tributary loopback (E1- RX port x FE): loopback at the tributary in the remote station. activation of any loopback of the previous loopbacks will indicate an abnormal condition in the NE.
156
Alcatel 9400 AWY version 2.0.4 Software Loop Back in 1+0 non protected link:IDU LOOP to check the IDU Equipment Tributary input loopback at your local station Near END ODU LOOP To check the path from the IDU to the ODU Connector
RF LOOP To check the whole path and to indicate if the problem is in your site or in the remote site
157
Alcatel 9400 AWY version 2.0.4 Software loop back:How to open the loopback menu ?
Trtributary loop back at local site IDU loopback ODU LOOP BACK RF Loop back
158
Alcatel 9400 AWY version 2.0.4 Software loop back:How to activate any loopback ? assume that we will make RF loop so you will follow the following steps as shown below
Abnormal condition list indicates RF loop back and AC became Blue colored
159
Alcatel 9400 AWY version 2.0.4 Software loop back in 1+1 HSB protection:we have additional 3 loops than 1+0 non protected ,these 3 loops performed through ch0 (extension unit).
Note that :you cannot activate any loops of ch0 if it is not the active unit therefore you can make (RF,IDU,ODU)loops of ch0 ,when ch0 is the active unit ie active in (TX , Radio protection and Mux/ Demux protection)
160
Alcatel 9400 AWY version 2.0.4 Software 2.5) Summary Block Diagram View:For The 1+1 HSB Configuration, The block diagram shows loopback available at 1+1 HSB
IDU loop of ch 1 tributary loop of ch 1 ODU loop of ch 1
RF loop of ch 0
Tributary loop of ch1 at remote site ODU loop of ch0 Tributary loop of ch0 at remote site
161
3)Alarms Handling:In this section we are going to describe the alarms and how to clear it, the most common repeated alarms is :-
1)High BER
2)Modulator fail 3) Demodulator fail 4)RX fail
5) TX fail
6)modulator los 7)demodulator los 8)loss of frame
162
3)Alarms Handling:to solve any of this alarms you should follow the following steps:1)Make RF loop to decide if the problem is in your site or in the remote site
if the alarms cleared and you have acceptable RX level at your local station
then go to the other site and do the following, you will make another RF loop and this alarms will not be cleared then the problem will be on your site to solve this problem follow this steps
163
3)Alarms Handling:How to replace ODU? Suppose that we have a 1+1 HSB link and we need to replace the extension ODU
164
3)Alarms Handling:2nd step remove the connector of the extension ODU as shown below.
165
3)Alarms Handling:3rd step plugged out the faulty extension ODU and determine the polarization towards the antenna for the new ODU as shown below and prepare the new ODU .
166
3)Alarms Handling:step 4: plug in the new ODU very well , and then put the IF connector as shown below. plugging in the New ODU IF connector is plugged in the ODU
3)Alarms Handling:How to change IDU? 1st step :switch off the IDU as shown below
168
3)Alarms Handling:2nd step: plug out all the cables (power, interfaces & IF) from their slots as shown below.
interfaces cables removed Upper slot indicates from 9 to 16 tributaries And the lower slot indicates from 1 to 8 tributaries
169
3)Alarms Handling:3rd step : plug out the flash card located at the back of the IDU last step: plug in the flash card into the new IDU carefully
last step: switch on the IDU after you plugged in all the cables(power, interfaces & IF)
170
3)Alarms Handling:other alarms:1)cable los: check the 2 IF Connectors and the IF cable carefully, if the problem still exists ,change IDU unit, then ODU if the problem still exists. 2)alarm replaceable unit type mismatch or 1.11.11.12.21 : ODU version is not compatible with the software version installed on the flash card , to solve this problem you can do the following a)change the new ODU with other one compatible with the flash card software version b) activate the 2nd software version it may be compatible with the ODU version and then reconfigure the link again
c)change the flash card with other one and its software version is compatible with the new ODU
3)Internal communication problem: check the connectors, then IDU 4)los of alignment: a problem in the radio protection switching , this alarm appears in 1+1 HSB Configuration only, to solve this problem see slide 150 5)incompatible shifter: apply the right shifter value for the operating frequency see slide 127
171
3)Alarms Handling:some problems may cause HIGH BER alarms and loss of frame:1)alignment problem : the reason of this problem is bad weather conditions or the support carrying the microwave is not well fixed , such that the RX level at both sites is not stable
172
3)Alarms Handling:some problems may cause HIGH BER alarms and loss of frame:2)Wave guide problem:the wave guide is rarely used in our network , this wave guide is used in nonintegrated antenna, any cut in this wave guide will effect the RX levels at local and far end to be very weak about -77 db which causes high BER to solve this problem Replace the wave guide with other one such that the RX level will be normal again and the BER alarm will be clear 3)Interference problem: This problem occurred when there is two microwave links have the same alignment and same frequency, this will gives an interference problem leading to high BER alarm
173
3)Alarms Handling:some problems may cause HIGH BER alarms and loss of frame:3)Interference problem: How can you identify the interference problem ?
1)switch off the transmission from your site and try to observe the RX level at the remote site , you will have RX level (this RX level is not from your opposite site)
but this is due to interference problem with other link 2) switch off the transmission form the remote site and try to observe the RX level at your local site, you will have RX level (this RX level is not from your opposite site) but this is due to interference problem with other link. from 1 & 2
you will observe that when you switch off transmission from any site, the other site will receive signal , this means that there is interference problem
174
3)Alarms Handling:some problems may cause HIGH BER alarms and loss of frame:How to solve Interference problem? a)avoid installation of links having the same alignment and frequency
b) using default frequencies : this frequencies can overcome the interference problem the table below shows the default frequencies can be used for mobinil bands.
Band BAND 23 GHZ Frequency high 23254000 25781000 38598000 Frequency low 22246000 24773000 37338000
Band 25 GHZ
Band 38 GHZ
175
3)Alarms Handling:some problems may cause HIGH BER alarms and loss of frame:4)Coupler problem:This problem occurs in 1+1 HSB configuration only , , if the coupler became faulty it may effects the RX level at both sites it will make losses about -20 db leading to high BER. how can you identify that this is coupler problem? a)check the equipments by RF loopback at the 2 sites. b)remove the coupler form 1 site and observe the RX level at both local and far ends, if the RX level became normal at both sites then the problem is in the coupler
we can solve this problem by changing the coupler with new one and if you don't have spare available, you can remove the faulty coupler such that the link became 1+0 from your side, and 1+1 from the other side.
176