You are on page 1of 2

CPR32-SE

Network Controller

CPR32-SE
CPR32-SE Network Controller is an optional Roger Access Control System (RACS) component. Using CPR32-SE in the system expands its functionality with specific features. When used with PRxx1 series controllers CPR32-SE allows for logging events and defining time-based access rights, as well as to realize global type functions such as APB zones or alarm zones. In case of PRxx2 series controllers, CPR32-SE provides a global type functions only (APB, alarm zones).

Data sheet Kontrolery serii CPR32-SE PRxx1

Features: One CPR32-SE unit per single access network with up to 32 controllers Real time clock with battery back-up Event buffer (250.000) Programmable inputs/outputs Two 1.5A/30V relay outputs Two 1A/15V transistor outputs Four NO/NC inputs RS485 interface (free topology) Relay output for alarm states signaling Firmware upgrade 1.5A buffered power supply 18-22 VAC supply CE mark

CPR32-SE-BRD Module

CPR32SE-BRD module in ME-1 metal enclosure, view and installation diagram

151.0 280.0

LED1 LED2 LED3 LED4

POT2 POT1 POT3

uP

LED5 LED6
S1 S2

Firmware Download Mode

B.Supp.

Memory uP Reset Reset

87.0

+ACC-

AC

+ AUX -

NO1

COM1

NC1

NO2

COM2

NC2

IO1

IO2

IN1

COM

IN2

IN3

COM

IN4

A B CLK + TML RS485 SHLD DTA

290.0

Metal Enclosure ME-1

Battery

Transformer

Available versions and symbols Symbol CPR32-SE-BRD ME-1 ME-2 ZMPR-1 ME-2-S Description
Network controller electronic module (board) Metal enclosure for installation of 1 CPR32-SE board (includes 40VA transformer) Metal enclosure for installation of four CPR32-SE boards (ZMPR-1 required, includes 80VA transformer) Set of two metal shelves and additional accessories dedicated to install up to four CPR32-SE boards into single ME-2 metal enclosure Metal enclosure with 80VA transformer and ZMPR-1 assembly kit pre-prepared for installation of four CPR32SE modules

Technical Specification Parameter Supply voltage Power consumption Environmental class Dimensions H x W x D Weight Approvals Value
18-22 VAC lub 10-15VDC 30VA Class I, Indoor, temperature: +5C - +40C, relative humidity: 10 to 95% (non-condensing) 151 X 87 mm 100g CE

ROGER sp.j Gociszewo 59 82-400 Sztum Poland

T. +48 55 272 0132 F. +48 55 272 0133 E. roger@roger.pl I. www.roger.pl

CPR32-SE Data Sheet, Version 1.0EN Rev.A 2010 ROGER sp. j. All content, specifications and availability subject to change without prior notice.