You are on page 1of 25

Get NMS information of NE from WO or RTN Status sheet

check NE type NE Gateway

check NE IP

10.66.X.Y

10.160.X.Y

Set Laptop IP as 10.66.X.Y+1

Set Laptop IP as the Gateway of NE

open Weblct by click start weblct

User name:admin &&& password:T200

Add NE by known Both NE IP and NE ID

User name:lct --Password: password NE Explorer Make backup of Alarms(print screen) Make backup of IF 1+1 protection (print screen) Make backup of IF/ODU configuration (print screen) check which IF cards you need to upgrade by Compare link design with IF/ODU Configuration

Make backup of cross connection configuration (print screen)

Make backup of Clock source priority

Check SCC version by right click on SCC >SCC version 5.54.01.22=R1 open Toolkit by click toolkit.bat connect to toolkit server put laptop IP Click on load software Click on Board and Software package (Simulation) Click on System Click on create NE Put NE ID

User name:szhw &&& password:nesoft Check NE Click on add to list >>

click on Browse icon in upgrade version

Open package file ne.pkg uncheck all IF Cards to be upgrade Click Start Click Activate Click Finish Right Click on NE in operation list--> remove from list by weblct Delete cross connection, IF 1+1 protection clock and source of needed IF Cards by weblct delete needed IF cards on slot layout Install EMS6 Board in Subrack Empty Slot

Replace IF1A by IFH

by weblct add needed IFH cards on slot layout

by weblct add needed IFH cards on slot layout

by weblct add EMS6 cards on slot layout

by Toolkit right click on NE --> Query Board Check NE

click on Browse icon in upgrade version

Open package file ne.pkg uncheck all Cards except needed IF cards and EMS6 Click Start Click Activate Click Finish uncheck NE

0X0001

check ODU version

do not upgrade ODU 0X004 check needed ODUs check SCC Click on add to list >> Click on ODU upgrade version browse Click on Add software open Oduboxup.hwx Click Start Click Activate Click on SCC upgrade version browse Click on Add software Click on ini open license file Click Start

Click Activate

Set 1+1 protection as backup

Set ODU/IF configuration as backup

Set Hybrid/AM configuration

Set IF Channel Spacing

Set AM Enable/Disable
AM--> Enable Set Modulation mode of the assured AM capacity

Modulation mode of the Full AM capacity

Set Assured E1 Capacity

Set cross connection configuration as backup

Set Clock source priority as backup

Check link performance

Check Sites with EOT

Print screen for Acceptance

Get NMS information of NE from WO or RTN Status sheet

check NE NE Non-Gateway

Set Laptop IP as 129.9.X.Y

10.160.X.Y

Set Laptop IP as the Gateway of NE

open Weblct by click start weblct

User name:admin &&& password:T200

Add NE by known Both NE IP and NE ID

User name:lct --Password: password NE Explorer Make backup of Alarms(print screen)

Make backup of IF 1+1 protection (print screen) Make backup of IF/ODU configuration (print screen) check which IF cards you need to upgrade by Compare link design with IF/ODU Configuration

Make backup of cross connection configuration (print screen)

Make backup of Clock source priority

Check SCC version by right click on SCC ->SCC version 5.54.02.22=R2 Install EMS6 Board in Subrack Empty Slot by Weblct add EMS6 open Toolkit by click toolkit.bat connect to toolkit server put laptop IP Click on load software Click on Board and Software package (Simulation) Click on System Click on create NE Put NE ID

User name:szhw &&& password:nesoft Check NE Click on add to list >>

click on Browse icon in upgrade version

Open package file ne.pkg uncheck all IF Cards to be upgrade Click Start Click Activate Click Finish Right Click on NE in operation list--> remove from list by weblct Delete cross connection, IF 1+1 protection clock and source of needed IF Card by weblct delete needed IF cards on slot layout

Replace IF1A by IFH

by weblct add needed IFH cards on slot layout by Toolkit right click on NE --> Query Board Check NE

click on Browse icon in upgrade version

Open package file ne.pkg uncheck all Cards except needed IF cards Click Start Click Activate Click Finish uncheck NE

check ODU version

0X001

do not upgrade ODU 0X0004

check needed ODUs Click on add to list >> Click on ODU upgrade version browse Click on Add software open Oduboxup.hwx Click Start Click Activate

Set 1+1 protection as backup

Set ODU/IF configuration as backup

Set Hybrid/AM configuration

Set IF Channel Spacing

Set AM Enable/Disable
AM--> Disable Set Manually specified Modulation Set Assured E1 Capacity

Set cross connection configuration as backup

Set Clock source priority as backup

Check link performance

Check Sites with EOT

Print screen for Acceptance

How to get NE ID and NE IP of NE in site

Set Laptop IP as 129.9.X.Y Open Navigator

NE ID

235

Laptop IP as 129.9.X.Y Open Navigator

what is HW upgrade for R3? 1 1- Replace IF1A by IFH2 2-Install EMS6 board what is SW upgrade for R3? 2 1- Upgrade Subrack to R3 excluding All IF1A cards 2-Upgrade EMS6 and IFH2 to R3 what is Ethernet connection needed? 3 1- Connect IFH2 to EMS6 2-Connect EMS6 to External source(Node-B) what is Ethernet connection needed? 4 1- Connect IFH2 to EMS6 2-Connect EMS6 to External source(Node-B) There is LICENSE_LOST alarm when the SCC version is upgraded from R1 to R2/R3 ? 5 we need to load the license again when the SCC version is upgraded from R1 to R2/R3 There is NO_BD_SOFT alarm in IF1A(IF1B) card when the SCC board is upgraded 6 from R1 to R2/R3 ? We need to load the load the second FPGA file if1p.pga to if we upgrade from R2 to R3 License download is needed? 7 NO

if we upgrade from R1 to R3 License download is needed? 8 Yes

Do we need to upgrade the ODU software if we use the AM function? 9 Yes

Is the ODU software upgraded automatic when the IDU software is upgraded? 10 No

if there are ODUs cannot be Upgraded? 11 Yes

EMS6 can be installed in Slot4? 12 if we upgrade to R3 (5.54.03.30) EMS6 can be installed in slot4

if there is no empty Slot for EMS6? 13 we install new subrack with SCC, PXC and EMS6 upgrade to R3

How to know which IF cards needed to upgrade? 14 1-Lable, 2-From NOC and most accurate compare link design parameters Tx frequency, TX power, RSL or Radio work mode Why I cannot delete IF Card? 15 you have to delete 1+1 protection, cross connection and clock source related to IF Card

After Upgrading finished but the 2G and 3G down 16 Check: IF channel spacing, modulation and E1 capacity must be the same for near and far end sites and then Cross connection as backup

IT IS FORBIDDEN LIST
1 2 3 4 5 6 7 8 9 10 11 12 13 14 It is forbidden to delete any cross connection is not related to needed IF Card (which needed to be upgrade) It is forbidden to delete IF 1+1 protection is not related to needed IF Card (which needed to be upgrade) It is forbidden to delete Clock source is not related to needed IF Card (which needed to be upgrade) It is forbidden to forget to take back up from cross connection configuration It is forbidden to forget to take back up from link configuration for all IF cards in subrack It is forbidden to forget to take back up from 1+1 protection for all IF cards in subrack It is forbidden to forget to know Subrack Release one or Release two It is forbidden to forget to know ODU HW version by using Navigator It is forbidden to upgrade ODU which is 0X0001 HW version It is forbidden to remove IF cable while ODU power supply is turned ON It is forbidden to Connect IF cable while ODU power supply is turned ON It is forbidden to Upgrade IF1A Cards which is not needed to upgrade It is forbidden to leave site without checking with NOC that everything is OK It is forbidden to forget to reconnect any NMS cables needed to be disconnected while upgrade operation

which needed to be upgrade) h needed to be upgrade) eeded to be upgrade)

subrack ubrack

ed while upgrade operation

SN

Technical Case
Q1- during the upgrade of the license , there was choose of file type as auto rather than .ini , after 1 upgrading the license and try to connect with the WebLct , connection fails , there was many trials to connect but no action. while trying to delete the IF1A board after deleting the cross-connection the board could no be deleted. 2 in 1+0 link I delete the IF cross connection all , then delete the clock source priority , then try to delete the card but also an error. I go to one site trying to find ID or IP data of that site to login, I check with NOC , but that link is not 4 managed , and I could not find any ip data about even I use navigator to got the connection but I find no solution. I can login to the IDU with the Navigator, but if I use WebLct to login with the ID and IP I have I got error 5 message [ LCT acess failure , or LCT access disable]. 3 after I upgrade the NE-SOFT of the IDU and the ODU oduboxup.hwx , I have critical Alarm MW_LOF and 6 RSL_LOW , I check the RSL of that IDU it was -40 dB , but the Actual Transmit power was -55dB and the odu changed to mute state , I try to reconfigure the T In WebLCT After the staff double-clicks startWebLct and using the password T2000 of the user admin in the IE window, The IE window disappears and only the background window of the Tomcat is displayed. User try to add NE and login but always fail , he che

Q8- during the upgrade after replacing the IFA1 with IFH2 and upgrading the FPGA files of the new IF board 8 , RSL is normal , cross connections has been restored , but services still down.

after upgrading all and trying to return the cross connection in Hub site have around 16 E1 service, there was an error message illegal operation, invalid low order number. Cross connection cannot be added.

Solution
making hardware restart of the IDU , then after login only SCC card was found and other boards definition lost > in the layout right click on PXC boards then select add physical board then add the other boards , then check your ODU RX-Level and Frequency IF Board could not be deleted for one of three reasons [Cross connection relation to be deleted all, clock source priority of that IF card to be deleted all, IF 1+1 protection group to be deleted all]. after you go to the clock source priority tab under Clock folder in NE explorer and select the IF Card and press delete , the card actually did not deleted till you press apply. I you fail to login by the id you have in the sheet , but the opposite friend in the other site can login by navigator , he can simply after he login to his IDU to click on the button Login in the left upper corner of his navigator window , the he write y go back to navigator and write this command: cfg set lctaces: enable, then check that your command accepted by writing the command :cfg-get-lctaces: then press enter , then try to login again by WEBLCT. go to IDU frequency tab , choose BY Function in the upper right corner of the window , then from pull down arrow select Frequency range , record that range , go back and reselect BY BOARD check button , then check if the actual transmit frequency is withi A- Run the Web LCT again and check the pop-up IE window. The tool Google Toolbar is found below the address bar. 1-Click the menu setting > help > uninstall of the toolbar. After the toolbar is uninstalled, the Web LCT runs normally. 2-Or in Control-Pannel Add/Remve programs, remove any installed toolbars. B- Check if it is found that either the Google Toolbar or the Yahoo Toolbar is installed in the notebooks. click the Pop-up Blocker button in the toolbar to change the state to show blocked popups. Then, the Web LCT runs normally. C- Open normal IE window , select tools >> Pop-up Blocker >> Pop-up Blocker Settings >> in the allowed sites Pan , select all then >> remove all. D- if your PC has another IE such as Firefox or safari or NetScape , then you have to make IE your default browser following below steps You can always choose default applications in windows. To do follow these steps: 1. Open "Control Panel" 2.1) If you are using Windows Vista. 2.1.1) Open "Default Programs" 2.1.2.) Click on "Set your default programs" 2.1.3) In the programs list on the left hand side choose "Internet Explorer", and on the right hand side of the window suitable options will be highlighted. 2.1.4) Click on the "Set this program as default" button. 2.2) If you are using Windows XP. 2.2.1) Open "Add/Remove Programs" 2.2.2) Open "Set Program Access and Defaults" 2.2.3) click on Custom Choose a Default Web browser and select "Internet Explorer" E- if your PC has macromedia Flash install on it , in IE , select Tools>>Manage Add-ons , then disable Macromedia flash.

Owner
Osama Osama Osama Osama

Osama

Osama

Osama

S8- mailbox of the New IFH2 fails to report properly after upgrading the FPGA file board hardware failure, in the navigator write the command : alm-get-all , try to replace the IFH2 with another board and re-upload the FPGA file. right click the upgraded IFH2 , choose IF interface , then under the selection item AM/Hybrid , check both 1-BW = 14MHz , Modulation = 16-QAM , then click apply. 2-Check assured E1 capacity = 20 E1, then configure the E1 Capacity = 16 E1

Osama

Osama

License Calculation

License calculation formula for each 4xE1 capacity Assume that network planning defines one microwave hop with NxE1s. The formula of the 4xE1 license quot 1+0 configuration and the formula of the 4xE1 license quotation (M) in the case of the 1+1 configuration are a In the case of the 1+0 configuration, M = (N/4-1) *4 In the case of the 1+1 configuration, M =(N*2/4-1)*4

The calculation of the license quotation for each STM-1 is simple. That is, the quotation result is equal to the

cense Calculation

with NxE1s. The formula of the 4xE1 license quotation (M) in the case of the ation (M) in the case of the 1+1 configuration are as follows:

simple. That is, the quotation result is equal to the number of STM-1s.

If the upgrade fails, the OptiX ToolKit displays a message, indicating an upgrade failure.

Operations to Be Performed if the ODU Is Offline After the Upgrade Is Complete


Step 1 Run the following command on the Navigator -->:radio-cfg-set-odu-upmode:Bid, 1 Step 2 Power off and reset the ODU. Step 3 Follow the upgrade flow to perform another upgrade by using the OptiX ToolKit. Step 4 If the board to be upgraded is not displayed in the Object Tree, manually add this board as follows: Right-click the NE to be upgraded, and choose Add Board from the shortcut menu.

Enter the slot ID of the board.

The board in this slot is displayed in the Object Tree.

ys a message, indicating an upgrade failure.

ne After the Upgrade Is Complete

-odu-upmode:Bid, 1

the OptiX ToolKit. , manually add this board as follows: hortcut menu.

You might also like