PRODUCT GROUPS
Accumulators ............................................................................................................................ 2 Alarm, monitoring and control systems ................................................................................. 4 Automatic control systems of working parameters ............................................................ 11 Cables ...................................................................................................................................... 15 Computer systems .................................................................................................................. 18 Electric motors ........................................................................................................................ 37 Fire detection systems and their components ...................................................................... 40 Generators and generating sets ............................................................................................. 47 Internal communication systems .......................................................................................... 49 Main propulsion control systems .......................................................................................... 50 Other electric products .......................................................................................................... 56 Power electronics .................................................................................................................... 59 Power operated valves and servo-motors ............................................................................. 62 Remote control systems of auxiliary machinery and installations .................................... 64 Sensors and transducers ........................................................................................................ 65 Switching and protection devices .......................................................................................... 67 Telegraphs ............................................................................................................................... 81 Transformers .......................................................................................................................... 81 Units, automatic components and other automatic systems .............................................. 83
Volume "TE"
TE/1919/880010/11
Product: ACCUMULATORS Type: MK 8G... SBL... 12 / 12i / 12i(sh) / 6i LC R... / X... / QA UP RW General technical data:
MK: Type: valve regulated, gel. Voltage (V): 6 / 12. Capacity C20 (Ah): 31 ... 225. SBL: Type: valve regulated, AGM. Voltage (V): 6 / 12. Capacity C20 (Ah): 7,2 ... 240. LC, UP: Type: valve regulated, AGM. Voltage (V): 6 / 12. Capacity C20 (Ah): 1,3 ... 210.
Volume "TE" 3
TE/1913/880012/11
Product: LEAD-ACID ACCUMULATORS Type: MARINE 75Ah, 100Ah; ENERGY PLUS 60Ah, 80Ah, 100Ah; 175Ah; 185Ah; TRUCK 110Ah, 125Ah, 135Ah, 143Ah, 145Ah, 170Ah, 175Ah, 180Ah, 190Ah, 200Ah, 210Ah, 230Ah General technical data: Accumulator Voltage [V]Capacity C20 [Ah] Starting current (-18C) battery type acc. to EN [A]
MARINE MARINE ENERGY PLUS ENERGY PLUS 12 12 12 12 75 100 60 80 600 720 480 600
ENERGY PLUS ENERGY PLUS ENERGY PLUS TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK TRUCK
TRUCK
12 12 12 12 12 12 12 12 12 12 12 12 12 12
12
100 175 185 110 125 135 143 145 170 175 180 190 200 210
230
720 900 1000 680 690 800 950 760 950 980 1000 1050 1100 1050
1100
TE/1914/880012/11
Product: LEAD-ACID MAINTENANCE FREE ACCUMULATORS Type: EXPEDITION PLUS AGM 70Ah, 95Ah
Volume "TE"
12
95
780
TE/1740/883087/08
Product: MARINE MODULAR GENERATOR SET CONTROLLER Type: InteliGen and InteliSys marine controllers General technical data:
Power supply: 24 V DC IGS-NT Component set IG-NTC LT GC Marine InteliGen IG-Display Display IGS-LSM+PMS DongleDongle to enable load sharing and power management IG-AVRi-MarineAVR interface IG-AVRi-TRANS-MarinePower supply for IG-AVRi-Marine IS-NT-BB MarineInteliSys, Marine central control system (central unit) IS-Display Display I-LBA Low battery adapter I-AOUT88 analogue output interfaces I-RB8 Relay board with 8 relays I-RB8-231Relay board with 8 relays for 231 Vac I-MTU 2:1Main transformer unit I-LB+ Local bridge I-CR Interface module HW/SW Version IS-NT-BB Marine 1.x / 2.x IG-NTC-LT GC Marine 1.x / 2.x
Volume "TE" 5
DEIF A/S
TE/1941/880465/12
Product: GENERATOR AND MAINS CONTROL, MONITORING AND PROTECTION UNITS Type: UniLine comprising: RMV-112D/122D/132D/142D; RMC-111D/121D/122D/131D/132D; RMP-111D/112D/121D; RMQ-111D/121D; RMF-112D; FAS-113DG/115DG/125DG; HAS-111DG; EPN-110DN; LSU-112DG/113DG/114DG/122DG; RMT-111Q96; AL8-2; MIC-2; CSQ-3 General technical data: Permissible ambient temperature range: -25 +70C. Enclosure protection degree: IP40 (case), IP20 (terminals); exceptions (for case): AL8-2 panel IP54 (front), MIC-2 instrument IP52 (front) IP30 (rear), CSQ-3 relay IP52 (front). Product description: RMV-112D/122D/132D/142D: Under / over voltage relay (including 2 levels and single phase). RMC-111D/121D/122D/131D/132D: Short-circuit / over current relay (including 2 levels), differential current relay. RMP-111D/112D/121D: Overload / reverse power relay. RMQ-111D/121D: Loss of excitation / overexcitation relay. RMF-112D: Underfrequency / overfrequency relay. FAS-113DG/115DG/125DG: Synchroniser (without / with voltage matching, automatic static synchronization). HAS-111DG; EPN-110DN: Paralleling relay. LSU-112DG/113DG/114DG/122DG: Load sharing unit, var load sharing unit. RMT-111Q96: Phase sequence relay. AL8-2: Alarm panels. MIC-2: Multi-instrument.
Volume "TE"
Dr E. HORN GmbH
TE/1858/883041/10
Product: ENGINE SAFETY SYSTEM Type: Engine Safety Module: ESM-20 Engine Indication Units: WIP-11 and WIP-21 General technical data: ESM-20 Power Supply: two redundant power buses Power Supply Range: 18-32 VDC (24VDC nominal) Current Consumption: 4,7A (max 5A) Degree of Protection: IP20 WIP-11/WIP-21 Power Supply: two redundant power buses Power Supply Range: 18-32 VDC (24VDC nominal) Current Consumption: 0,3A - idle, 0,5A - typical, 1,0A - maximum Degree of Protection: IP67 front panel, IP20 rear side
TE/1730/883039/08
Product: CRANK CASE MONITORING AND PROTECTION SYSTEM Type: MAN SPLASH-OIL MONITORING SYSTEM General technical data: Main hardware components: - PLC central unit type 07 KT 94 (ABB) or type I/O System 750 (WAGO); - Operation Panel type T70 (Beijer Electronics AB). Software:
Volume "TE" 7 PLC: ABB 07 KT 94 PLC: 1.4.xxx or WAGO750-842 controller: 6.0.4. Operation Panel: MT 91 panel: 1.4 (with ABB), 2.0.xxx (with WAGO); Beijer T70 panel: 1.0.4 (with WAGO).
MAN Diesel SE
Holeby Denmark
TE/1787/883929/09
Product:
Base module, type BM Operation box, type OB Monitor temperature/pressure module, type MTP Monitor exhaust gas temperature module, type MEG Output module, type OM General technical data: Power supply: 24 V d.c., 35 W.
TE/1781/883089/08
Product: MONITORING and CONTROL SYSTEM Type: MCS-5 General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008. TE/1782/883089/08 Date of issue : 2008-12-22 Date of validity: 2013-12-22
Volume "TE"
General technical data: According to MTU catalogue No. br1445-08 dated 07/2008. TE/1783/883089/08 Date of issue : 2008-12-22 Date of validity: 2013-12-22
Product: ENGINE CONTROL SYSTEM Type: ECS-5 BlueVision General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008. TE/1863/883089/10 Date of issue : 2010-03-15 Date of validity: 2013-12-22
Product: MONITORING AND CONTROL SYSTEM Type: MCS-5 General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008 and 10sb1069 dated 03/2009 (PAN5 to PAN8 for MCS-5). TE/1864/883089/10 Date of issue : 2010-03-16 Date of validity: 2013-12-22
Product: Propulsion Plant Remote Control System Type: RCS-5 General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008 and 10sb1069 dated 03/2009 (ROS 14-01/FPP and ROS 14-01/CPP for RCS-5). TE/1933/883089/12 Date of issue : 2012-07-11 Date of validity: 2017-07-12
Product: MTU Integrated Automation / Field Automation Level (FAL) Type: Controller Module: PCD 2, PCD 3, PCD 4 Bus Coupler Module: BID 1, BID 2, BID 3 Power Module: PID 1, PID 2 Digital Input Module: DID 1, DID 2 Digital Output Module: DOD 1, DOD 2, DOD 3, DOD 4 Analogue Input Module: AID 1, AID 2, TID 1, TID 2, TID 3 Analogue Output Module: AOD 1, AOD 3 Function Module: FID 1, PWD 1 Serial Interface Module: SID 1, SID 2, SID 3
TE/1915/883128/11
Product: SHIP AUTOMATION SYSTEM Type: Maxi/Mega Guard E-Series General technical data: According to the system components specified in appendix to the certificate.
TE/1882/883124/11
Product: ENGINE ROOM CONTROL AND MONITORING SYSTEM Type: EMOS 4.x General technical data: According to the system components manufacturers data sheet.
10 Volume "TE"
Selco A/S
TE/1845/880462/10
Product: SUPERVISION AND CONTROL UNITS Type: M1000 - Alarm Annunciator M2000 - Engine Controller M2100 - Emergency Controller General technical data: Rated supply voltage: M1000: 12-24 VDC / 48-110 V DC; M2000, M2100: 12 VDC / 24 VDC. Outputs rated current (each unit): max 150 mA per channel/output. Degree of protection of front side (each unit): IP32 / IP54. Additional technical data of M1000 unit: Alarm delay: programmable. Resistance in sensing cable: max. 1000 . Ambient temperature (each unit): -10 .. +70 oC. TE/1848/880462/10 Date of issue : 2010-02-02 Date of validity: 2015-02-01
Product: INSULATION MONITORING RELAY Type: T3200 General technical data: Max. voltage: 660 VAC. Voltage range: 80 .. 110 %. Frequency range: 45 .. 65 Hz. Overall accuracy: 5 % of preset value. Insulation level: 0 .. 5 M. Delay: 1 .. 10 sec. Ambient temperature: -20 .. +70 oC.
Volume "TE" 11
Siemens AG, I IA CE
TE/1869/880423/10
Product:
Monitoring Relay
Type:
TE/1726/883103/08
Product: SEPARATOR AND PUMP CONTROL SYSTEM Type: TYPE: EPC 50 S, EPC 50 P, EPC 50 V, EPC 50 E, EPC 50 BI, EPC 50 W General technical data: Rated voltage, frequency: 100, 112.5, 230V, 50/60Hz. Ambient temperature: max. 55C. Enclosure protection: IP 54. TE/1727/883103/08 Date of issue : 2008-04-02 Date of validity: 2013-04-02
Product: FUEL CONDITIONING MODULE CONTROL SYSTEM Type: EPC 50 B, CONTROL AND STARTER CABINET
12 Volume "TE" General technical data: Rated supply voltage, frequency: 3-phase, 400/440/480V up to 690V, 50/60Hz. Rated control voltage, frequency: 1-phase, 115/230 V, 50/60Hz. Ambient temperature: max. 55C. Enclosure protection: IP 54. TE/1757/883103/08 Date of issue : 2008-09-08 Date of validity: 2013-11-20
Product: Control System for ECOSTREAM Bilge Water Treatment Module Type: EPC 50 BWPX General technical data: Supply rated voltage: 3-phase, from 210V up to 690V 50/60 Hz. Control circuits rated voltage: 1-phase, 100V/115V/230V 50/60 Hz. Max. permissible ambient temperature: 55C. Enclosure protection: IP54. TE/1758/883103/08 Date of issue : 2008-09-08 Date of validity: 2013-08-22
Product: CONTROL CABINET FOR SEPARATOR SYSTEMS Type: EPC - 50 General technical data: Supply rated voltage: 100; 112.5; 230V 50/60Hz. Control circuits rated voltage: 24VAC. Operator interface (OP) supply rated voltage: 24VDC. Max. permissible ambient temperature: 55C. Enclosure protection: IP54. System is to be used with MT 50 water/moisture transducer. TE/1926/883103/12 Date of issue : 2012-06-12 Date of validity: 2017-06-11
Product: CONTROL UNITS FOR SEPARATION SYSTEMS Type: EPC 41 EPC 400
Enics Sweden AB
Skeppsbyggaregatan 9
S-201 24 Malm, Sweden for Alfa Laval Tumba AB
Volume "TE" 13
General technical data: Supply rated voltage: 48V 50/60 Hz. Max. permissible ambient temperature: +55C. Enclosure protection degree: IP44. Control Units type EPC41 are intended for separation systems type MOPX, MMPX, WHPX. Control Units type EPC400 are intended for separation systems type FOPX, LOPX. Control Units software is configured according to selected type of a.m. separation system and external equipment (e.g. preheater system). TE/1960/883103/13 Date of issue : 2013-02-25 Date of validity: 2018-02-24
Product: FUEL CONDITIONING MODULE CONTROL SYSTEM (CONTROL AND STARTER CABINET) Type: EPC 50 B Enics Sweden AB, Skeppsbyggaregatan 9, S-201 24 Malm, Sweden.
Certificate holder:
General technical data: Supply rated voltage: 400/440/480 up to 690V, 50/60Hz. Control circuits rated voltage: 115/230V, 50/60Hz. Max. permissible ambient temperature: +55C. Enclosure protection degree: IP54. TE/1961/883103/13 Date of issue : 2013-02-25 Date of validity: 2018-02-24
Product: CONTROL CABINET FOR SEPARATION SYSTEMS Type: EPC 50 Enics Sweden AB, Skeppsbyggaregatan 9, S-201 24 Malm, Sweden.
Certificate holder:
General technical data: Supply rated voltage (primary voltage): 100/112,5/230V 50/60Hz. Max. permissible ambient temperature: +55C. Enclosure protection degree: IP54.
Engineered Machined Products, Inc. 3111 N. 28th St. MI 49829 Escanaba United States of America
TE/1761/883083/08
Product: ELECTRONIC THERMOSTAT General technical data: Rated voltage: 12 or 24 VDC Enclosure: IP56
TE/1823/883201/09
General technical data: System components: 1) Sensor, type No.: 0279-0096. 2) Interface box, type No.: 0379-0148. Power supply rated voltage: 115/230V 50/60Hz (selectable). Measurement range: Viscosity: 0..25 or 0..50 mPas (other ranges on request). Temperature: 0..200 oC. Measurement accuracy: Viscosity: 2% instantaneous with a minimum of 0,5 mPas.
Volume "TE" 15 Temperature: 1 oC. Max. permissible temperature of liquid: 180 oC (higher temperatures on request). Enclosure protection of each component: IP65. Ambient temperature: -20..+55 oC.
1000 East Drake Road CO 80525 Fort Collins United States of America
TE/1760/883083/08
Product: FUEL CONTROL VALVE (FCV) AND POWER MODULE Type: FOR C175 CATERPILLAR ENGINES General technical data: Rated voltage: 12 or 24 VDC Enclosure: IP56
Cables
Tele-Fonika Kable Sp. z o.o., S.K.A. Wielicka 114 30-663 Krakw Poland
TE/1842/880565/10
Product:
16 Volume "TE" 2 x 1 to 50 mm2 3 x 1 to 240 mm2 4 x 1 to 185 mm2 (4 x 1 do 240 mm2 for NKOGs) 5 x 1 to 70 mm2 7, 10, 12, 16, 19, 20, 24, 27, 30, 37 x 1 to 2,5 2 mm 14 x 1,5 mm2 9 x 1,5 mm2 for NKOGsekw TE/1843/880565/10 Date of issue : 2010-04-20 Date of validity: 2015-04-19
Product:
MARINE CABLES
Type:
NKOXS, NKOXSekw
General technical data: Rated voltage: Maximum rated conductor temperature: Crosssectional area of conductor: 0.6/1 kV +90C 1 x 1 to 300 mm2 2 x 1 to 50 mm2 3 and 4 x 1 to 240 mm2 5 x 1 to 70 mm2 6, 8, 9, 14 x 1,5 mm2 7, 10, 12, 16, 19, 20, 24, 27, 30, 37 x 1 to 2,5 Date of issue : 2010-04-20 Date of validity: 2015-04-19
mm2 TE/1844/880565/10
Product:
SINGLECORE WIRES
Type:
LGs
General technical data: Rated voltage: Maximum rated conductor temperature: Cross-sectional area of conductor: TE/1930/880565/12 300/500 V and 450/750 V +180C from 0.25 to 10 mm2 for 300/500 V from 0.5 to 120 mm2 for 450/750 V Date of issue : 2012-06-04 Date of validity: 2015-04-19
Product:
MARINE CABLES
NTKOXSekw
General technical data: Rated voltage: Maximum rated conductor temperature: Crosssectional area of conductor: 150 / 250V ( 300V ) +90C 1 37 x 2 x ( 0,5; 0,75; 1,0; 1,5 ) mm2 1 12 x 3 x ( 0,5; 0,75; 1,0 ) mm2 1 16 x 3 x 1,5 mm2 1 x 4 x 2,5 mm2 2 x 2 x 2,5 mm2 2 37 x 0,75 mm2 Date of issue : 2012-06-04 Date of validity: 2015-04-19
TE/1931/880565/12
Product:
MARINE CABLES
Type:
FLAME-X950 NTKOGsekw
General technical data: Rated voltage: Maximum rated conductor temperature: Crosssectional area of conductor: 150 / 250V ( 300V ) +90C 1 37 x ( 0,75; 1,0; 1,5 ) mm2 1 x 3 x ( 0,75; 1,0; 1,5 ) mm2 1 x 4 x ( 0,75; 1,0; 1,5 ) mm2 1 x 2 x 2,5 mm2 Date of issue : 2012-06-04 Date of validity: 2015-04-19
TE/1932/880565/12
Product:
MARINE CABLES
Type:
NTKOXSekf/ekw
General technical data: Rated voltage: Maximum rated conductor temperature: Crosssectional area of conductor: 150/250V (300V) +90C 1 37 x 2 x 0,75 mm2 1 16 x 3 x 0,75 mm2 1 27 x 2 x 1,5 mm2 1 24 x 3 x 1,5 mm2
18 Volume "TE"
Computer systems
Atea AS Kongsberg Askeladden 3 3602 Kongsberg Norway
TE/1808/883236/09
Product:
PERSONAL COMPUTER
Type:
For a complete approved component list, refer to the relevant Components Options list.
TE/1918/883236/11
Product:
PERSONAL COMPUTER
Type:
For a complete approved component list, refer to the relevant Components Options list.
Product:
PERSONAL COMPUTER
Type:
For a complete approved component list, refer to the relevant Components Options list.
TE/1731/883236/08
Product: PROCURVE SWITCH Type: HP Models: 1400-8G (J9077A), 1400-24G (J9078A), 1700-8G (J9079A), 1700-24G (J9080A). General technical data: Rated voltage: 100-127 / 200-240 V AC Power consumption: 18 W (8G) / 24 W (24G) Switching capacity: 3.4 Gbps for model J9079A, 8.4 Gbps for model J9080A 16 Gbps for model J9077A, 48 Gbps for model J9078A. Operating temperature: 0C to 40C Mariner Kit: HP Procurve Switch must be used in conjunction with the Mariner Kit MS650 or MS660.
Product:
PERSONAL COMPUTER
Type:
For a complete approved component list, refer to the relevant Mariner Systems Components Options list. Mariner Kit: The personal computer must be used in conjunction with the Mariner Kit MS2170 (horizontal mount) or MS2180 (vertical mount). TE/1786/883236/09 Date of issue : 2009-01-15 Date of validity: 2014-01-15
Product:
PERSONAL COMPUTER
Type:
For a complete approved component list, refer to the relevant Mariner Systems Components Options list. Mariner Kit: The personal computer must be used in conjunction with the Mariner Kit MS2150 (Desktop configuration) or MS2160 (Minitower configuration).
Product:
WORKSTATION
Type:
HP Z400
Models: Refer to Mariner Systems website www.marinersystems.com General technical data: Processor: Intel Xenon W3570 (3.20/1333/8M); Intel Xenon W3540 (2.93/1066/8M); Intel Xenon W3520 (2.66/1066/8M); Intel Xenon W3505 (2.53/1066/4M); Intel Xenon W3503 (2.40/1066/4M); Memory: Hard Disk: 16, 12, 8, 6, 4, 3, 2 or 1 GB DDR3-1333 ECC Unbuffered RAM; 500 GB SATA 3.0 Gb/s (7200 rpm); 250 GB SATA 3.0 Gb/s (7200 rpm); 160 GB SATA 3.0 Gb/s (7200 rpm); 146 GB SAS 3.0 Gb/s (7200 rpm); NVIDIA Quadro NVS 290 256MB DH PCIe x16; NVIDIA Quadro FX 380 256MB PCIe x16; NVIDIA Quadro FX 1800 768MB PCIe x16; NVIDIA Quadro FX 4800 1,5GB PCIe x16
Graphics Card:
For a complete approved component list, refer to the relevant Mariner Systems Components Options list. Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS3010 (Desktop configuration) or MS3020 (Minitower configuration). TE/1828/883236/10 Date of issue : 2010-01-11 Date of validity: 2015-01-10
Product:
HP LA1951g
Type:
22 Volume "TE"
Mariner Kit: The monitor must be used in conjunction with the Mariner Kit MS1080 (Desk Mount), MS1085 (Wall Mount) or MS1090 (Console Mount). TE/1829/883236/10 Date of issue : 2010-01-11 Date of validity: 2015-01-10
Product:
HP LA1905wg
Type:
Product:
HP LA2205wg
Type:
Product:
HP LA2405wg
Type:
Product:
PERSONAL COMPUTER
Type:
24 Volume "TE" Optical Drive: SATA SuperMulti LightScribe DVD Writer; SATA DVD-ROM; Graphics Card: NVIDIA Quadro NVS 290 256MB DH PCIe x16; NVIDIA Quadro NVS 295 PCIe x16; NVIDIA GeForce 310 DP PCIe x16; HP ADD2 SDVO + DVI-D Adapter; Intel Graphics Media Accelerator 4500 (integrated).
For a complete approved component list, refer to the relevant Mariner Systems Components Options list.
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2210 (Desktop configuration) or MS2220 (Minitower configuration). TE/1866/883236/10 Date of issue : 2010-04-16 Date of validity: 2015-04-15
Product:
PERSONAL COMPUTER
Type:
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2230 (Horizontal Mount) or MS2240 (Vertical Mount).
Volume "TE" 25
TE/1916/883236/11
Product:
PERSONAL COMPUTER
Type:
Intel Pentium G850 (2.9GHz/3M/2 cores); Intel Pentium G840 (2.8GHz/3M/2 cores); Intel Pentium G630 (2.7GHz/3M/2 cores); Intel Pentium G620 (2.6GHz/3M/2 cores); Memory: Up to 16 GB DDR3 PC3-10600 (1333MHz) RAM; Hard Disk: 1 TB SATA 6.0 Gb/s (7200 rpm); 500 GB SATA 6.0 Gb/s (7200 rpm); 250 GB SATA 6.0 Gb/s (7200 rpm); 160 GB SATA 3.0 Gb/s (7200 rpm) 2.5-inch; 80 GB SATA 3.0 Gb/s Solid State Drive; Optical Drive: SATA SuperMulti LightScribe DVD Writer; SATA DVD-ROM; Graphics Card: AMD Radeon HD 6350 (PCIe x16); AMD Radeon HD 6450 (PCIe x16); AMD FirePro 2270 (PCIe x16); NVIDIA NVS 300 (PCIe x16); Intel HD Graphics 2000/3000 (integrated).
For a complete approved component list, refer to the relevant Mariner Systems Components Options list.
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2250 (Desktop configuration) or MS2260 (Minitower configuration). TE/1917/883236/11 Date of issue : 2011-10-19 Date of validity: 2016-10-18
Product:
PERSONAL COMPUTER
Type:
26 Volume "TE" Intel Pentium G850 (2.9GHz/3M/2 cores); Intel Pentium G840 (2.8GHz/3M/2 cores); Intel Pentium G630 (2.7GHz/3M/2 cores); Intel Pentium G620 (2.6GHz/3M/2 cores); Memory: Up to 16 GB DDR3 PC3-10600 (1333MHz) RAM; Hard Disk: 1 TB SATA 6.0 Gb/s (7200 rpm); 500 GB SATA 6.0 Gb/s (7200 rpm); 250 GB SATA 6.0 Gb/s (7200 rpm); 160 GB SATA 3.0 Gb/s (7200 rpm) 2.5-inch; 80 GB SATA 3.0 Gb/s Solid State Drive; Optical Drive: SATA SuperMulti LightScribe DVD Writer; SATA DVD-ROM; Graphics Card: AMD Radeon HD 6350 (PCIe x16); AMD Radeon HD 6450 (PCIe x16); AMD FirePro 2270 (PCIe x16); NVIDIA NVS 300 (PCIe x16); Intel HD Graphics 2000/3000 (integrated).
For a complete approved component list, refer to the relevant Mariner Systems Components Options list.
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2270 (Horizontal mount) or MS2280 (Vertical mount). TE/1928/883236/12 Date of issue : 2012-06-05 Date of validity: 2017-06-04
Product:
HP Compaq LA2006x
Type:
Product:
HP Compaq LA2306x
Product:
PERSONAL COMPUTER
Type:
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2310 (Desktop configuration) or MS2320 (Minitower configuration).
Product:
PERSONAL COMPUTER
Type:
Mariner Kit: The workstation must be used in conjunction with the Mariner Kit MS2330 (Horizontal mount) or MS2340 (Vertical mount). TE/1948/883236/12 Date of issue : 2012-11-23 Date of validity: 2017-11-22
Product:
HP Compaq LA2405x
Type:
Volume "TE" 29 Mariner Kit: The monitor must be used in conjunction with the Mariner Kit MS1270 (Desk Mount), MS1275 (Wall Mount) or MS1280 (Console Mount). TE/1956/883236/13 Date of issue : 2013-01-29 Date of validity: 2018-01-28
Product:
HP Compaq LA1956x
Type:
Mariner Kit: The monitor must be used in conjunction with the Mariner Kit MS1150 (Desk Mount), MS1155 (Wall Mount) or MS1160 (Console Mount).
TE/1939/883245/12
Product: PROGRAMMABLE LOGIC CONTROLLERS Type: The Melsec FX3U Series Base Units: 16I/Os: FX3U-16MR/DS, FX3U-16MR/ES, FX3U-16MT/DSS, FX3U-16MT/DS, FX3U16MT/ESS, FX3U-16MT/ES; 32I/Os: FX3U-32MR/DS, FX3U-32MR/ES, FX3U-32MT/DSS, FX3U-32MT/DS, FX3U32MT/ESS, FX3U-32MT/ES; 48I/Os: FX3U-48MR/DS, FX3U-48MR/ES, FX3U-48MT/DSS, FX3U-48MT/DS, FX3U48MT/ESS, FX3U-48MT/ES; 64I/Os: FX3U-64MR/DS, FX3U-64MR/ES, FX3U-64MT/DSS, FX3U-64MT/DS, FX3U64MT/ESS, FX3U-64MT/ES; 80I/Os: FX3U-80MR/DS, FX3U-80MR/ES, FX3U-80MT/DSS, FX3U-80MT/DS, FX3U80MT/ESS, FX3U-80MT/ES; 128I/Os: FX3U-128MR/ES, FX3U-128MT/ESS, FX3U-128MT/ES;
30 Volume "TE" Accessories: Expansion Board FX3U-USB-BD, FX3U-232-BD, FX3U-485BD, FX3U-422-BD, FX3U485BD, FX3U-CNV-BD; Display Module FX3U-7DM; Memory Cassette FX3U-FLROM16 /-64 /-64L; Special Adapter FX3U-232ADP, FX3U-232ADP-MB, FX3U-232ADP-MBH, FX3U485ADP, FX3U-485ADP-MB, FX3U-485ADP-MBH, FX3U-4AD-ADP, FX3U-4DA-ADP, FX3U4AD-PT-ADP, FX3U-4AD-TC-ADP, FX3U-4HSX-ADP, FX3U-2HSY-ADP General technical data: Rated supply voltage: 24VDC / 100-240VAC Ambient temperature: max 55C Supply circuit protection: from 3,15A to 5A * * depending on used Base Unit.
TE/1874/883239/10
Series PCD1 / PCD2 / PCD4 / PCD7 and Compact Controllers PCS1 General technical data: Rated voltage: 24 VDC. Enclosure protection (IP) and other technical details according to manufacturers catalogue available on http://www.sbc-support.ch/ . List of modules: specified in Annex No.1. TE/1875/883239/10 Date of issue : 2010-12-06 Date of validity: 2015-12-05
Volume "TE" 31 General technical data: Rated voltage: 24 VDC. Enclosure protection (IP) and other technical details according to manufacturers catalogue available on http://www.sbc-support.ch/ . List of modules: specified in Annex No.1. TE/1876/883239/10 Date of issue : 2010-12-06 Date of validity: 2015-12-05
Type: Series PCD7.D410 and PCD7.D457 General technical data: Flush mounted Web Panels with embedded MicroBrowser. Rated supply voltage: 18 .. 32 VDC. Enclosure protection: IP65. Max. permissible ambient temperature: +50C. Other technical details according to manufacturers catalogue and manuals available on http://www.sbc-support.ch/ . List of modules: specified in Annex No.1.
TE/1749/883243/09
TE/1751/883243/09
TE/1752/883243/09
Product: OPERATOR DIALOGUE TERMINAL Type: MAGELIS XBTGT, XBTN-R General technical data:
According to Catalogues: - No. KATKT86820 for Magelis XBT N, XBT R - No. KATKT86840 for Magelis XBT GT
TE/1813/883243/09
Product:
PLC
Type:
MODICON M340
General technical data:
According to Catalogues No. KATKT31580.
Volume "TE" 33
Siemens AG, I IA AS
TE/1896/883241/11
Product: PROGRAMMABLE LOGIC CONTROLLER Type: SIMATIC S7-200 General technical data: CPU: 6ESS7-210, -211, -212, -214, -215, -216, -221, -222, -224, -226; Digital expansion modules: 6ES7-221, -222, -223; Analogue expansion modules: 6ES7-231, -232, -235; Memory module: 6ES7-291; Simulator: 6ES7-274; HMI TP200: 6ES7-272; Communication processor: 6GK7-243; Positioning module: 6ES7-253; Modem expansion module: 6ES7-241; Text display: TD200; Ethernet module: CP243. TE/1897/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: SIMATIC OPERATOR PANEL OP SIMATIC TEXT DISPLAY TD Type: OP3, OP5, OP7, OP15, OP17, TD17 General technical data: According to SIEMENS Catalog CA 01 10/2005 TE/1898/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE LOGIC CONTROLLER Type: SIMATIC S7/M7-300 General technical data: List of modules as specified in Appendix to the certificate.
34 Volume "TE"
TE/1899/883241/11
Product: PROGRAMMABLE LOGIC CONTROLLER Type: LOGO! General technical data: Equipment: LOGO! with suffixes: 12RCL, 12/24RC, 12/24Rco, 24R, 24, 24o, 24C, 24Co, 24L, 24RC, 24Rco, 24RCL, 24RCLB11, 230RC, 230R, 230Rco, 230RCL, 230RCLB11, DM8 24, DM 8 24R, DM8 12/24R, DM8 230R, AM2, AM2 PT100, DM16 230R, DM 16 24R, DM 16 24, AM2 AQ, AM2 RTD, TD. TE/1900/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE LOGIC CONTROLLER Type: SIMATIC ET 200B, ET 200C, ET 200L, ET 200L-SC, ET 200M, ET 200S, ET 200X, ET 200eco, ET200ecoPN, SC, ET 200pro General technical data: List of modules as specified in Appendix to the certificate. TE/1901/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE LOGIC CONTROLLER WITH OPERATOR CONTROL PANEL Type: SIMATIC C7 Control System General technical data: Components: C7-613, C7-621, C7-623, C7-624, C7-626, C7-633, C7-634, C7-635, C7-636 Extension module; C7-623, C7-630 TE/1902/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: DISTRIBUTED INPUT / OUTPUT UNITS Type: ET 200iSP General technical data: List of components as specified in Appendix to the certificate.
Volume "TE" 35
TE/1903/883241/11
Product: INDUSTRIAL COMMUNICATION SYSTEM Type: SIMATIC NET General technical data: Equipment: Scalance: 6GK5 104-2, 6GK5 414, 6GK5 106-1, 6GK5 108, 6GK5 204-2, 6GK5 206-1, 6GK5 208, 6GK5 744, 6GK5 788, 6GK5 491, 6GK5 492, 6GK5 495, 6GK5 496, 6GK5 005, 6GK5 101, 6GK5 112, 6GK5 116, 6GK5 124, 6GK5 202-2 IRT, 6GK5 204-2, 6GK5 204 IRT, 6GK5 212, 6GK5 216, 6GK5 224, 6GK5 307, 6GK5 308, 6GK5 310, 6GK5 408 Security Module: 6GK5 602, 6GK5 612, 6GK5 613 Power Supply: 6GK5 791 Modular Outlet: 6GK1 901 IE/PB Link: 6GK1 411 OBT: BT: OSM: ESM: OLM: TE/1904/883241/11 6GK1 500 6GK1 500 6GK1 105 6GK1 105 6GK1 503 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PANEL SYSTEM Type: SIMATIC: OP73, OP77, OP177B, OP270, OP277, TP170, TP177A, TP177B, TP177micro-6, TP270, TP277 MP177, MP270/370, MP277 KTP400/600 MP377-15 Daylight General technical data: List of modules as specified in Appendix to the certificate. TE/1905/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE LOGIC CONTROLLER Type: SIMATIC: S7-400 M7-400 General technical data:
Components:
S7-400:
36 Volume "TE" PS405, PS407, IM178, IM460, IM461, IM463, IM467 SM421, SM422, SM431, SM432, FM450, FM451, FM452, FM453, FM455, FM456, FM458 CP140, CP440, CP441, CP443, CP444 UR1, UR2, CR2, ER1, ER2 CP1401 SB10, SB61, SB71, SU12, SU13 Fan subassembly 408 M7-400: PS405, PS407 CPU488, CPU486 EXM438, EXM448, EXM478 MSM478, MSM456 ATM478 IF961, IF962, IF963, IF964 MC952 DIM/MEM478 UR1, UR2, CR2, ER1, ER2 Fan subassembly 408 TE/1906/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE ELECTRONIC SYSTEM Type: FAIL SAFE PLC AND FAIL SAFE MODULES General technical data: Components:
S7-400 CPU412-3H, CPU414-4H, CPU416F-2 ET 200M 6ES7 195 CPU416F-3 PN/DP, CPU417-4H ET 200eco 6ES7 148 S7-300 SM326 DI24 x DC24V ET 200pro 6ES7 148 SM326 DI8 x NAMUR SM326 DO8/10xDC24V/2A SM336 AI6 x 13Bit 6ES7 315 CPU 315F-2DP 6ES7 317 CPU 317F-2DP 6ES7 319 CPU319F-3 PN/DP ET 200S 6ES7 138 4/8F-DI, 4F-DO, PM-E-F, 3F-DO, 1F-RO 6ES7 151 IM151-7F CPU 6ES7 151 IM151-8F PN/DP Safety protector 4/8/16F-DI, 4F-DO 4/8/16F
TE/1907/883241/11
Product: SIMATIC FLAT PANEL MONITORS Type: Flat Panel Monitor: 12, 15, 17, 19 Flat Panel Touch: 12, 15, 17, 19 Flat Panel Key: 12, 15 General technical data:
24V and 120/240V power supply Protection rate IP65/NEMA 4 (front when mounted) Bright TFT display with a large viewing angle VGA and DVI-D interfaces
Product: INDUSTRIAL PERSONAL COMPUTER Type: SIMATIC Microbox PC 427B / 427B-RTX SIMATIC IPC 427C / 427C Bundle SIMATIC HMI IPC 477C SIMATIC Microbox PC 427B PCS 7 AS RTX SIMATIC IPC 427C PCS 7 OS Client SSD / AS RTX SIMATIC IPC627C SIMATIC IPC 647C SIMATIC HMIIPC677C General technical data: According to Siemens Catalog ST 80 / ST PC 2010. TE/1909/883241/11 Date of issue : 2011-08-26 Date of validity: 2016-08-26
Product: PROGRAMMABLE LOGIC CONTROLLER Type: SIMATIC S7-1200 General technical data: Components: CPU Units: CPU 1211C, CPU 1212C, CPU 1214C Signal Modules: Communication Modules: Signal Boards: Power Supply Modules: Memory Cards: SM 1221, SM 1222, SM 1223, SM 1231, SM 1232, SM 1234 CM 1241 SB 1221, SB 1222, SB 1223, SB 1232 PM 1207 Simatic MC
Electric motors
ABB AB LV Motors rjansgrnd 31 721 70 Vsteras Sweden
TE/1878/880195/11
38 Volume "TE" Type: 4 poles 1500/1800 motors 6 poles 1000/1200 motors power [kW] power [kW] 50Hz 60Hz 50Hz 60Hz 14BG223-4 (225M) 45 52 14BG258-6 (250M) 45 54 14BG228-4 (225M) 55 63 14BG280-6 (280S) 45 54 14BG253-4 (250M) 55 63 14BG283-6 (280M) 55 66 14BG258-4 (250M) 75 86 14BG288-6 (280M) 75 90 14BG280-4 (280S) 75 86 14BG310-6 (315S) 75 90 14BG283-4 (280M) 90 104 14BG313-6 (315M) 90 108 14BG288-4 (280M) 110 127 14BG316-6 (315L) 110 132 14BG310-4 (315S) 110 127 14BG317-6 (315L) 132 158 14BG313-4 (315M) 132 152 14BG318-6 (315L) 160 184 14BG316-4 (315L) 160 184 14BG317-4 (315L) 200 230 14BG318-4 (315L) 250 288 General technical data: Insulation class: F Protection class: IP55 Remaining data according to Lonne catalog available on http://www.lonne.com TE/1934/880193/12 Date of issue : 2012-08-16 Date of validity: 2017-08-15
Product:
LOW-VOLTAGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS
Type:
M2AA 160 up to M2AA 250 (Aluminium frame) M2BA 160 up to M2BA 250 (Cast iron frame) Sizes: MLA, MLB, MLC, MLD, MLE, SMA, SMB, SMC
TE/1935/880193/12
Product:
LOW-VOLTAGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS
Type:
M3AA 160 up to M3AA 280 (Aluminium frame)
Volume "TE" 39
Sizes: MLA, MLB, MLC, MLD, MLE, SMA, SMB, SMC, SMD
TE/1936/880193/12
Product:
LOW-VOLTAGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS
Type:
M3BP 160 up to M3BP 250 (Cast iron frame)
Sizes: MLA, MLB, MLC, MLD, MLE, SMA, SMB, SMC, SMD
40 Volume "TE"
TE/1922/930052/11
Product: FIRE ALARM MANUAL CALL POINT Type: BF-300, BF-300V2, BF-300M, BF-300M/N BF-500V2/EX, BF-501, BF-501/N, BF-501/EX BF-502, BF-502/N, BF-502/EX, BF-503,BF-503/N, BF-503/EX, BF-510WP-H General technical data: Fire Alarm Manual Call Points with Self Verify function. TE/1937/930052/12 Date of issue : 2012-07-12 Date of validity: 2015-03-05
Product: AUTROPRIME INTERACTIVE FIRE DETECTION SYSTEM Type: Fire Alarm Control Panels BS-200M Repeater Panel BS-211 Fire Brigade Panel BU-210 Information Panel BV-210 Mimic Driver BUR-200 General technical data: Protection class: IP32 Operating temperature: from -15C to +70C Power Supply: 115/230 VAC, 50/60 Hz (BS-200M) 18-30 VDC (BS-211, BU-210, BV-210, BUR-200) Loops: 4 (BS-200M) Capacity loop units: 127 per loop (BS-200M) Batteries: 2 x 12V = 24 V (not included) TE/1943/930052/12 Date of issue : 2012-09-17 Date of validity: 2016-12-11
Volume "TE" 41 Type: Ex Zener Barrier Unit BZ-500 Smart Buzzer BBR-52 Electronic Sounder BBR-200 I/O-Units: BN-300/310/320, BN-500/Ex BN-303, BN-304, BN-305, BN-307 BNB 330A, BN-331 BNY -330 General technical data: I/O units Type AutroSafe. Version: BN-300 Input Unit with Self Verify function. BN-500/Ex - Input Unit with Self Verify function. Eexia BN-310 Single Relay Output Unit. BN-320 I/O Unit with Self Verify function. AutroSafe Ex Barrier Unit BZ-500: 24V DC, IP55 BN-303 Single Monitored Input Unit BN-304 - Single Monitored Input/Output Unit BN-305 Dual Monitored Input/Output Unit BN-307 Monitored Fire Alarm Device Control Unit BNB-330A Conventional Loop Interface BNB-331 Conventional Loop Interface BNY-330 End of Line Unit TE/1950/930052/12 Date of issue : 2012-12-06 Date of validity: 2016-12-11
Product: FIRE DETECTORS Type: BH-200, BH-300, BH-500, BH-500/EX, BH-500/N, BD-200, BD-300, BD-500, BD-500/EX, BD-500/N, BH-220, BH-320, BH-520, BH-520/EX, BH-520/N BG-21, BG-201 General technical data: Heat Detector BD-200 Optical Smoke Detector BH-200 Combined Heat/Smoke Detector BH-220 Heat Detectors with Self Verify function BD-300, BD-500, BD-500/EX, BD-500/N Optical Smoke Detectors with Self Verify function - BH-300, BH-500, BH-500/EX, BH500/N Combined Heat/Smoke Detector with Self Verify function - BH-320, BH-520, BH-520/EX, BH-520/N IR Flame Detector BG-21, BG-201
42 Volume "TE"
TE/1949/930052/12
Product: ANALOGUE ADDRESSABLE AND CONVENTIONAL FIRE DETECTION AND GENERAL ALARM CENTRAL UNIT SALWICO CCP Type: Salwico Workboat Salwico Cruise Salwico Cargo Salwico LNG Salwico Offshore Salwico Ro/Pax Salwico Yacht Salwico Navy General technical data: All module are listed in appendix.
Kidde Products
Dawdon Business Park, Unit 2 Blair Way, Seaham, Co. Durham United Kingdom
TE/1796/883023/09
Product: OIL MIST DETECTOR Type: GRAVINER MARK 6 General technical data: Power supply rated voltage: 24V DC (dual power supply). Control circuits rated voltage: 24V DC. Max. permissible ambient temperature for system components: Control panel, junction box and detector: 70C. Enclosure protection index of system components: 1. Junction box and detector: IP65. 2. Control panel: IP32.
Volume "TE" 43
Max. number of junction boxes: 8. Max. number of detectors: 64. TE/1912/883023/11 Date of issue : 2011-09-02 Date of validity: 2016-09-01
TE/1791/930052/09
Product: FIRE ALARM CENTRAL UNIT Type: Minerva MX Marine T2000 T2000CV, T2000R, T2000CV R General technical data: According to publication 17A-02-D: Rated voltage: 24 VDC Enclosure protection: IP42 Operating temperature: -8...+55C Additional conditions and remarks: The T2000 may be extended by the following modules: PSB800, Power Supply Module FB800, Fuse Board OCM800, Operator Control Module
44 Volume "TE" ODM800, FIM800, CPU800, TLI800, XLM800, IOB800, MPM800, ANN880, ANN840, COM820, Operator Display Module Field Wiring Interface Central Processing Unit Optional Network Card Expansion Loop Module Input/Output Board Interface Board Programmable 80 LED alarm status module Programmable 40 LED alarm/fault status module Programmable 20 LED / 20switch control and status module Date of issue : 2009-03-12 Date of validity: 2014-03-12
TE/1792/930052/09
Product: FIRE DETECTORS Type: 801CHEx IS Enhanced CO Detector 801HEx IS Heat Detector 801PHEx IS Enhanced Smoke Detector 811CH Enhanced CO Detector 811CHExN ExN Enhanced CO Detector 811F Point Flame Detector 811FEx IS Point flame Detector 811H Detector 811HExN ExN Heat Detector 811PC Smoke, Heat and CO Detector 811PH Enhanced Smoke Detector 811PHExN ExN Enhanced Smoke Detector 802SB Addressable Sounder Base 5B 5" Base 5BEx 5" IS Base 5BI 5" Isolator Base General technical data: According to the following datasheets: 5B 17A-02-5B - iss 3 5BEx 17A-02-5BEx - iss 1 5BI 17A-02-5BI - iss 3 801CHEx 17A-02CHEx - iss 1 801HEx 17A-02-HEx - iss 1 801PHEx 17A-02-PHEx - iss 2 802SB 17A-02-SB2 - iss 5 811CH 17A-02-CH - iss 02 811CHExN 17A-02-CHExn - iss 1 811F 17A-02-F - iss 3 811FEx 17A-02-Fex - iss 2 811H 17A-02-H - iss 02 811HExN 17A-02-Hexn - iss1 811PC 17A-02-PC - iss 3 811PH 17A-02-PH - iss 02
Volume "TE" 45 811PHExN TE/1793/930052/09 17A-02-PHExn - iss 1 Date of issue : 2009-03-12 Date of validity: 2014-03-12
Product: MANUAL CALL POINTS Type: CP820M Indoor Call Point CP830M Outdoor Call Point CP840Ex IS Call Point General technical data: According to the following datasheets: CP820M 17A-02-CP820/CP820M - iss 4 CP830M 17A-02-CP830/CP830M - iss 2 CP840Ex 17A-02-CPEx - iss 1 TE/1794/930052/09 Date of issue : 2009-03-12 Date of validity: 2014-03-12
Product: ANCILLARIES FOR FIRE ALARM CONTROL SYSTEM, T2000 Type: DIM800 Detector Input Module EXI800 IS loop Interface HVR800 High Voltage Relay Interface IF800Ex IS Contact Input Module MIM800 Mini Input Module MIO800 Multi Input/Output Module RIM800 Relay Interface Module SNM800 Sounder Notification Module General technical data: According to the following datasheets: DIM800 17A-02-DIM - iss 3 EXI800 17A-02-EXI - iss 1 HVR800 17A-02-HVR - iss 5 IF800Ex 17A-02-IFEx - iss 1 MIM800 17A-02-MIM - iss 3 MIO800 17A-02-MIO - iss 1 RIM800 17A-02-RIM - iss 4 SNM800 17A-02-SNM - iss 2 TE/1795/930052/09 Date of issue : 2009-03-12 Date of validity: 2014-03-12
Product: FIRE DETECTORS Type: S231f+ Conventional Output Flameproof Flame Detector S231i+ Conventional Output IS Flame Detector
46 Volume "TE" S241f+ 4-20mA Output Flameproof Flame Detector S241i+ 4-20mA Output IS Flame Detector S261f+ Relay Output Flameproof Flame Detector S271f+ Addressable Flameproof Flame Detector S271i+ Addressable IS Flame Detector General technical data: According to datasheet No. 120-415-400 - iss 9
Security House, The Summit, Hanworth Road, Sunbury-on-Thames Middlesex TW16 5DB United Kingdom
TE/1860/930052/10
Product: CONVENTIONAL FIRE DETECTORS; INTRINSICALLY SAFE CONVENTIONAL FIRE DETECTORS; BASES AND ACCESSORIES Type:
601F-M, 631H-F, 601P-M, 601PH-M, 601H-R-M, 601CH-M, 601H-F-M, 611H-F; 601FEx-M, MD601Ex, MD611Ex, MDU601Ex, MR601Tex; MUB, MUBEx, 5B, 5BEx, 5BD, DHM-5B
Volume "TE" 47
(1) -25C .. +70C [Short-Term: up to +90C]. (2) max. 28 VDC (intrinsically safe loop). (3) IP20. 5BD: 5 conventional diode continuity base and accessories for use with the series 600 detectors. (1) -25C .. +70C [Short-Term: up to +90C]. (2) max. 33VDC (polarity conscious). (3) IP20. DHM-5B: deckhead mounting kit for use with the series 600 detectors. (1) -25C .. +70C. (3) IP55.
TE/1819/880209/09
Product:
Cummins Onan MDK series (4-32 kW): MDKBH, MDKBL, MDKBN, MDKBP, MDKBR, MDKBS/MDKBT, MDKBU
General technical data: Engine Type MDKBH MDKBH MDKBL MDKBL MDKBN MDKBN MDKBP MDKBP MDKBR MDKBR Kubota Kubota Kubota Kubota Kubota Kubota Kubota Kubota Kubota Kubota Power (kW) 5 4 9 7 13,5 11 17 13,5 21,5 17,5 27,5 22,5 32 27 Voltage (V) 120/240 110/220/115/230/240 120/240 110/220/115/230/240 120/240 110/220/115/230/240 120/240 120/208 110/220/115/230/240 220/380 120/240 120/208 110/220/115/230/240 220/380 120/240 120/208 110/220/115/230/240 220/380 120/240 120/208 110/220/115/230/240 Frequency (Hz) Phases 60 50 60 50 60 50 60 60 50 50 60 60 50 50 60 60 50 50 60 60 50 1 1 1 1 1 1 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1
TE/1942/880209/12
Product:
Frequency [Hz]
John Deere John Deere 35 40 1500 1500 110/220 110/220 115/230 115/230 120/240 120/240 110/190 110/190 115/200 115/200 120/208 120/208 110/220 110/220 115/230 115/230 120/240 120/240 220/380 220/380 230/400 230/400 240/416 240/416 255/400 255/400 50 50
John Deere John Deere John Deere 50 40 55 1500 1800 1800 110/220 120/240 120/240 115/230 120/208 120/208 120/240 127/220 127/220 110/190 120/240 120/240 115/200 139/240 139/240 120/208 240/416 240/416 110/220 255/440 255/440 115/230 277/480 277/480 120/240 220/380 230/400 240/416 255/400 50 60 60
John Deere 65 1800 120/240 120/208 127/220 120/240 139/240 240/416 255/440 277/480
60
Volume "TE" 49
TE/1925/883040/12
Product:
Zenitel Norway AS
TE/1958/880575/13
Product: HANDS FREE TWO-WAY VOICE COMMUNICATION SYSTEMS Type: Command Talk Back systems: CTB-10, CTB-20 and CTB-100 General technical data: Centrals: CU-10, CU-20, CU-100, CU-200. Operator Panels: CTB10, CTB-10W/V01, CTB-20, CTB-20W/V01. Talk Back Substations: STB-1, STB-2, STB-3, STB-5, STB-6, H112M. PA Power Amplifiers: AW8121-120W, AW8241-240W, P8501-500W.
50 Volume "TE" PA Call station: VMT-603, VMP-603. Power Supply unit: SPS-4. TE/1959/880575/13 Date of issue : 2013-03-12 Date of validity: 2018-03-11
Product: TWO-WAY VOICE COMMUNICATION SYSTEMS Type: Command Talk Back systems: ETB-5, ETB-10 and ETB-100 General technical data: Centrals: ETB-5, ETB-10, ETB-100. Talk Back Substations: STB-1, STB-2, STB-3, STB-5, STB-6, H112M. Power Supply unit: SPS-4.
AB VOLVO PENTA
TE/1756/883087/08
Product: VOLVO PENTA Diesel Engine Control System Type: EMS General technical data: Rated voltage: 24 V d.c. The system comprises the following units: EMS Engine Monitoring System versions EMS1 & EMS2 PM Power Module MCC Marine Commercial Control Unit PCU Power Control Unit HCU Helm station Control Unit SDU Shutdown Module
Volume "TE" 51
CATERPILLAR Inc.
3701 State Road 26 East INDIANA 47905 Lafayette United States of America
TE/1814/883083/09
Product:
ADEM III
Type:
TE/1815/883083/09
Product:
ADEM III A3V9 Heui B (part No. 322-3601) for engine type C9, ADEM III A3V9 Hi-Volume (part No. 322-3602) for engine type C12 and C18, ADEM III 16 (part No. 322-3612) for engine type 3500B
General technical data: Rated voltage: 6,5 32 V DC.
Product: ELECTRONIC ENGINE CONTROL MODULE for CATERPILLAR ENGINES Type: ADEM IV (A4E4v2) ECM
Delphi Delco Electronics de Mexico S.A. de C.V. Carretera A, Matamoros KM 13.5 Parque Industrial Reynosa & Parque Industrial de Norte Reynosa, Tamaulipas, 88747, Mexico
General technical data: Power supply rated voltage: 12 or 24 V d.c. This Electronic Control Module is intended for Caterpillar and MaK engines.
TE/1951/883083/12
Product: ELECTRONIC ENGINE CONTROL MODULE for CATERPILLAR ENGINES Type: ADEM IV (A4E4v3.1) ECM
Delphi Delco Electronics de Mexico S.A. de C.V. Carretera A, Matamoros KM 13.5 Parque Industrial Reynosa & Parque Industrial de Norte Reynosa, Tamaulipas, 88747, Mexico
TE/1952/883083/12
General technical data: Power supply rated voltage: 12 or 24 V d.c. Enclosure protection degree: IP56. System components: ADEM IV (A4E4v3.1) ECM electronic control module, basic sensors (pressure, temperature), injectors, connectors. ADEM IV Electronic Control Module is intended for Caterpillar and MaK engines. TE/1954/883083/12 Date of issue : 2012-11-23 Date of validity: 2017-11-22
General technical data: Power supply rated voltage: 12 or 24 V d.c. ADEM IV Electronic Control Module is intended for Caterpillar and MaK engines. Particular system level schematics with sensors and I/O part Nos. index - see manufacturer documentation.
54 Volume "TE"
MAN Diesel SE
Frederikshavn Denmark
TE/1788/883929/09
Product:
ALPHATRONIC 2000-LMCS with the following components: Engine units: ACS (Alphacomm Safety) ACM-E (Alphacomm Monitoring Eng.) OP-E (Operator Panel Eng.) Gear units: ACM-GP (Alphacomm Monitoring Gear/Prop) OP-GP (Operator Panel Gear/Prop.) ASP12 (Closed Loop Servo Amplifier for Propeller) General technical data: Power supply: 24 V d.c., Degree of protection: IP 56.
TE/1775/883089/08
Product: PROPULSION CONTROL SYSTEM Type: PCS-5 General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008. TE/1784/883089/08 Date of issue : 2008-12-22 Date of validity: 2013-12-22
Volume "TE" 55 for Controllable Pitch Propeller CPP Waterjet WJ Voith-Schneider VS General technical data: According to MTU CD catalogue No. br1445-08 dated 07/2008.
TE/1923/883087/11
Product: ENGINE MANAGEMENT SYSTEM Type: EMS-S6 General technical data: Rated voltage: 24 V d.c. Degree of enclosure protection: IP 56 The following components are to be connected to the EMS system: T25, Oil pressure sensor, T26, Charge air pressure and temperature sensor, T27, Coolant temperature sensor, T28 & T29, Engine speed sensors.
TE/1759/883083/08
Product: ELECTRONIC MODULAR CONTROL PANEL Type: EMCP 3.3 General technical data: Rated voltage: 12 or 24 VDC Enclosure: IP56
56 Volume "TE"
TE/1824/880590/09
MBK 5/E-Z(-PE)
MBK 6/E
General technical data: Included in Phoenix Contact Catalogues: 1) ,,Clipline 2002, No. TNR 5123762/01.04.02-00. 2) ,,Clipline 09/10, No. MNR.52004772/15.04.09-00. TE/1825/880590/09 Date of issue : 2009-12-17 Date of validity: 2014-12-16
Volume "TE" 57 General technical data: Included in Phoenix Contact Catalogues: 3) ,,Clipline 2002, No. TNR 5123762/01.04.02-00. 4) ,,Clipline 09/10, No. MNR.52004772/15.04.09-00.
TE/1827/880590/09
TE/1733/880347/08
Product: LOW VOLTAGE DISTRIBUTION BOXES Type: RN model: 203015, 303015, 303021, 403015, 403021, 304015, 304021, 404021, 604021, 604025, 305021, 405021, 405025, 505021, 505025, 406021, 406025, 606021, 606025, 606030, 806030, 608021, 608025, 608030, 808025, 808030, 6010025, 8010025, 8010030, 8010040, 8012030, 8012040 General technical data: According to ERGOM catalogue. Zgodnie z katalogiem ERGOM-u. TE/1774/880347/08 Date of issue : 2008-12-22 Date of validity: 2013-12-22
58 Volume "TE" Type: RN model: 10010030, 10012030 General technical data: According to ERGOM catalogue. Zgodnie z katalogiem ERGOM-u. TE/1811/880347/09 Date of issue : 2009-06-08 Date of validity: 2013-12-22
Product: LOW VOLTAGE DISTRIBUTION BOXES Type: RNM model: 10010030, 10012030 General technical data: According to ERGOM catalogue. Zgodnie z katalogiem ERGOM-u. TE/1812/880347/09 Date of issue : 2009-06-08 Date of validity: 2013-04-20
Product: LOW VOLTAGE DISTRIBUTION BOXES Obudowy rozdzielnic niskonapiciowych Type: RNM model: 203015, 303015, 303021, 403015, 403021, 304015, 304021, 404021, 604021, 604025, 305021, 405021, 405025, 505021, 505025, 406021, 406025, 606021, 606025, 606030, 806030, 608021, 608025, 608030, 808025, 808030, 6010025, 8010025, 8010030, 8010040, 8012030, 8012040 General technical data: According to ERGOM catalogue. Zgodnie z katalogiem ERGOM-u.
TE/1763/880510/08
Product:
INNER CONVECTORS
Type: EOO I -IV General technical data: Rated power: 500 W, 1000 W, 1500 W, 2000 W Rated voltage: 230 V, 400 V, 440 V Enclosure protection: IP 65
Volume "TE" 59
TE/1764/880510/08
Product:
INNER CONVECTORS
Type:
OPO - 1
General technical data: Rated power: 250/400/500/750/1000/1500 W Rated voltage: 230/400/440 V AC 50-60Hz Enclosure protection: IP55
Power electronics
Schneider Toshiba Inverter Rue Andre Blanchet 27120 Pacy sur Eure France
TE/1744/880031/08
Product: SOFT STARTER Type: ALTISTART 48 General technical data: According to Catalogue No. KATKT72840 TE/1745/880031/08 Date of issue : 2008-10-21 Date of validity: 2013-08-07
Product: FREQUENCY CONTROLLER Type: ALTIVAR 11; 21; 31; 61; 71. General technical data:
According to Catalogues: No. ART. 038998 for type 11
No. KATKT 85210 for type 21 No. ART. 063912 for type 31 No. KATKT 85710 for type 61 and 71
60 Volume "TE"
Siemens AG A&D CD
TE/1734/880423/08
Product: AC SEMICONDUCTOR MOTOR STARTER Type: Type: SIRIUS 3RW442..., 3RW443..., 3RW444..., 3RW445..., 3RW446... General technical data:
29-93 113-162 203-432 551-970 1076-1214 Power rating AC53a (400V, 40C, In-Line-Circuit kW): 15-45 55-90 110-250 315-560 630-710 Rated frequency: 50/60 Hz Rated voltage: up to 690V AC Control voltages: 115V AC or 230 V AC Rated current Ie (400V, 40C, In-Line-Circuit A): for for for for for for for for for for 3RW442... 3RW443... 3RW444... 3RW445... 3RW446... 3RW442... 3RW443... 3RW444... 3RW445... 3RW446...
TE/1807/880423/09
Product: AC SEMICONDUCTOR MOTOR STARTER Type: Type: SIRIUS 3RW402..., 3RW403..., 3RW404... General technical data:
Rated current Ie (40C): 12,52 A; 25,3 A; 32,2 A; 38 A 45 A; 63 A; 72 A 80 A for 3RW4046 106 A for 3RW4047 for 3RW402... for 3RW403...
Power rating AC53a (400V, 40C, In-Line-Circuit kW): 5,5; 11; 15; 18,5 22; 30; 37 45 55 Rated voltage: Control voltage: 200 to 480 V ac ; 400 to 600 V ac 24 V ac/dc or 110 230 V ac/dc
Product:
COMPACT STARTER
Type:
SIRIUS 3RA6
General technical data: Rated current [Ie] and power:
ambient temperature 60oC
Siemens AG, I IA CE
TE/1889/880423/11
Product: SOLIDSTATE SOFT STARTERS & MOTOR CONTROLLERS Type: 3RW30 3RW31 General technical data:
According to Siemens Catalogue LV10 2004.
62 Volume "TE"
TE/1798/866502/09
Product: ACCESSORIES FOR HYDRAULIC POWER UNITS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1799/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: ACCESSORIES FOR PUMPS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1800/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: ELECTRO-HYDRAULIC SYSTEMS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1801/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: SENSORS, SIGNAL TRANSMITTERS & CONTROL PANELS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate.
Product: CONTROL CARDS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1803/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: AMPLIFIERS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1804/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: ELECTRONIC ACCESSORIES General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1805/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: LOGIC ELEMENTS General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate. TE/1806/866502/09 Date of issue : 2009-03-31 Date of validity: 2014-03-30
Product: ACCESSORIES FOR PROPORTIONAL TECHNOLOGY General technical data: The technical data are specified in Rexroth Bosch Group catalogue cards, referred to in Appendix to the Certificate.
64 Volume "TE"
IMI Norgren CZ
TE/1940/883405/12
Product: PNEUMATIC & HYDRAULIC PRESSURE SWITCHES Type: Series 18 D Pneumatic pressure switch types: 0880241, 0880341, 0880441, 0880641. Hydraulic pressure switch types: 0882141, 0882241, 0882341. General technical data: type pressure range max. pressure Pneumatic 0880241 0.2 to 2 bar 50 0880341 0.5 to 8 bar 80 0880441 1 to 16 bar 80 0880641 1 to 30 bar 80 Hydraulic 0882141 0882241 0882341 Degree of protection: 5 to 70 bar 10 to 160 bar 25 to 250 bar IP65 600 600 600
TE/1868/883027/10 Product:
Date of issue : 2010-08-02 Date of validity: 2015-08-01 AutoChief C20 PROPULSION CONTROL SYSTEM
K-Chief 500 / K-Chief 600 ALARM, MONITORING, CONTROL AND POWER MANAGEMENT SYSTEM
General technical data: Systems components: ROS, MOS, BWU-09, ACP, WBU, WCU, LTU, PBT, MPP, MPD, MEI, MSI-12, DGU, ESU, ESS, RPMU, RPMe, PSS, dPSC, SCU, VCC, RAi-16, RAi-16xe, RAi-10tc, RDi-32, RDi-32xe, RDi-32Axe, RDi-32a, RDo-16, RDo-16xe, RAo-8, RAo-8xe, RIO-C1, RIO-C2, RIO-C2xe, RIO-C3, RIO-C4, INP, ALC, TCP, CRP, PSO, PSO-P, CEG, Ixxat, ELACT 0512/1325/1335/2945 electric actuators, SEFA 160 servo fuel actuator. Supply voltage: 18 .. 32 VDC. Ambient temperature: -15C .. +55C / +70C. Maximum relative humidity: 96% non-condensing. Enclosure protection degree: DPUs (Distributed processing units): IP20/IP22; CRP (Control room panel), WBU (Watch bridge unit), WCU (Watch cabin unit): IP22; BWU-09 (Bridge wing unit), SEFA 160 (Servo fuel actuator): IP56.
TE/1957/883400/13
Product:
66 Volume "TE" 24 V AC/DC for ERH-...-07 and ERH--07-K 230 V AC/DC for ERH-...-16 IP 66 for ERH-...-06 IP 68 for ERH-...-07 and ERH--07-K IP 66 for ERH-...-16 II 1/2G cEx de IIBT4 for ERH-...-16
Explosion-proof enclosure:
TE/1885/883566/11
Product: TANK LEVEL SENSORS (PRESSURE TRANSMITTERS) Type: HCG2011-M04-FW HCG2011-M04-GW HCG2011-M04-KS POPRAWNY ADRES:
Hoppe Bordmesstechnik GmbH Kieler Strasse 318 D-22525 Hamburg Germany
General technical data: Rated supply voltage: 24 VDC. Measuring range: 0 4000 mbar. Output signal: 4 20 mA. Enclosure protection: IP68. Overload (overpressure) limit: up to 10000 mbar. Permissible ambient temperature: -10 +85 C. Permissible process temperature: FW/GW: -20 +120 C; KS: -20 +85 C. Explosion-proof (Ex) protection: II 2G Ex ia IIC T6. Temperature measurement (inside sensor): Pt-100, 2-wire (range: -40 +120 C). Application (medium): all mediums. Installation: FW/GW: - horizontal, outside tank; - bottom up (vertical), outside tank; KS: from the top (vertical), inside tank.
Volume "TE" 67
TE/1938/880477/12
Type: 4G 10, 4G 16, 4G 25, 4G 40, 4G 63, 4G 80, 4G 100, 4G 200, 4G 400, 4G 630, 4G 800, 4G 1200. General technical data: Rated insulation voltage: 690 V. Rated impulse withstand voltage: 4 / 6 / 8 kV. Enclosure protection degree: IP40 / IP55 / IP65. Switching programs and other technical data: APATOR S.A. Product Catalogue 2012 No. PL.00052/2012.
TE/1836/880422/10
Product:
CONTACTORS
Type:
DILA
DILM7 DILM9
DILM40
DILM50 DILM65
68 Volume "TE" DILM12 DILM80 DILM15 DILM95 DILM17 DILM115 DILM25 DILM150 DILM32 DILM170 General technical data: Rated operational voltage: up to 690 V a.c. Rated current: 22 to 225 A TE/1837/880422/10 Date of issue : 2010-04-30 Date of validity: 2015-04-29
Product:
up to 690 VAC for ZB12, ZB32, ZB65 up to 1000 VAC for ZB150 from 0.1 to 32 A for ZB12, ZB32 from 6 to 75 A for ZB65 from 25 A to 150A for ZB150 Date of issue : 2010-04-30 Date of validity: 2015-04-29
TE/1838/880422/10
Product:
Product:
CIRCUITBREAKERS
Type: FAZ B, FAZ C, FAZ D General technical data: Rated operational voltage: up to 230/400 VAC up to 48 VDC (in one pole)
Volume "TE" 69 Rated current: TE/1840/880422/10 up to 63 A Date of issue : 2010-04-30 Date of validity: 2015-04-29
Product:
CONTROL RELAYS
Type: EASY500 EASY700 EASY800 General technical data: Easy500 Power supply: 12VDC Easy-DA24VDC Easy-DC24VAC Easy-AB100/240VAC Easy-AC Digital inputs: 8 (2 can be used as analog for AB, -DA, -DC) Outputs: 4 relay or 4 transistor (DC-TC) Easy700 Power supply: 12VDC Easy-DA24VDC Easy-DC24VAC Easy-AB100/240VAC Easy-AC Digital inputs: 12 (4 can be used as analog for AB, -DA,-DC) Digital outputs: 6 relay or 8 transistor (DC-TC) Easy800 Power supply: 12VDC Easy-DA24VDC Easy-DC24VAC Easy-AB100/240VAC Easy-AC Digital inputs: 12 (4 can be used as analog for AB, -DA, -DC) Digital outputs: 6 relay or 8 transistor (DC-TC) or 1 analog (-DC) TE/1841/880422/10 Date of issue : 2010-04-30 Date of validity: 2015-04-29
Product:
ROTARY SWITCHES
Type: T0, T3, T5 General technical data: Rated operational voltage: Rated current: Ambient temperature without cover: with cover:
690 VAC. 20A (T0), 32A (T3), 63A (T5B), 100A (T5), from 25 to 50 C, from 25 to 40 C.
70 Volume "TE"
Moeller GmbH
TE/1830/880422/10
Product:
250 V a.c. for RMQ16 500 V a.c. for RMQ-Titan Date of issue : 2010-01-26 Date of validity: 2015-01-25
Product:
CONTACTORS
Type: DIL E(E)M-...(-G) DIL M 185 DIL M 225 DIL M 250 DIL M 300 DIL M 400 DIL M 500 General technical data: Rated operational voltage:
up to 690 V a.c. up to 1000 V a.c. (for DIL M) Conventional enclosed thermal current: up to 850 A TE/1832/880422/10 Date of issue : 2010-01-26 Date of validity: 2015-01-25
Product:
MOTORPROTECTIVE CIRCUIT-BREAKERS
Type: PKZM0-... PKZ2/ZM-... PKZM4-... General technical data: Rated operational voltage: Rated uninterrupted current:
Volume "TE" 71 0.40 to 40 A for PKZ2 10 to 63 A for PKZM4 TE/1833/880422/10 Date of issue : 2010-01-26 Date of validity: 2015-01-25
Product:
up to 690 V a.c. up to 1000 V a.c. (for Z5) 0.10 to 630 A Date of issue : 2010-01-26 Date of validity: 2015-01-25
Product:
SWITCH-DISCONNECTORS
Type: P1 P3 General technical data: Rated operational voltage: Rated current: TE/1835/880422/10
Product:
72 Volume "TE"
Schneider Electric
TE/1743/880459/08
Product: CONTACTOR Type: LC, CAD, LT, LR Series D, F, K General technical data:
According to Catalogue TeSys No. KATKT60000
Schneider Electric
TE/1741/880438/08
TE/1742/880438/08
Product: CIRCUIT BREAKER Type: SYSTEM MULTI 9 - C60; C120; NG; DPN General technical data:
According to Catalogue No. KATCDPDF2006
Schneider Electric
TE/1746/880459/09
Product: MOTOR CIRCUIT BREAKER Type: GZ1; GV2; GV3 General technical data:
According to Catalogue TeSys No. KATKT60000
Schneider Electric
TE/1753/880468/09
74 Volume "TE"
Schneider Electric
TE/1748/880551/09
Product: CONTROL and SIGNALLING UNITS Type: XB4 General technical data:
According to Catalogue No. KATKT12702
Selco A/S
TE/1846/880462/10
Product: PROTECTIVE RELAYS Type: T2000 - Reverse Power Relay T2200 - 3 Phase Overcurrent Relay T2300 - 3 Phase Short Circuit Relay T2500 - 3 Phase Overcurrent and Short Circuit Relay General technical data: Max. voltage (each unit): 660 VAC. Voltage range (each unit): 50/60 .. 110 %. Overall accuracy (each unit): 5 %. Trip level: T2000: 2 .. 20% IN T2200, T2500 (overcurrent): 0,5 .. 1,4 IN T2300, T2500 (short-circuit): 1,0 .. 4,0 IN Delay: T2000: 2 .. 20 sec. T2200, T2500 (overcurrent): 3 .. 30 sec.
Volume "TE" 75 T2300, T2500 (short-circuit): 0,1 ... 1,0 sec. Ambient temperature (each unit): -20 .. +70 oC. TE/1847/880462/10 Date of issue : 2010-02-02 Date of validity: 2015-02-01
Product: FREQUENCY RELAY Type: T3000 General technical data: Max. voltage: 660 VAC. Voltage range: 70 .. 110 %. Frequency range: 40 .. 70 Hz. Overall accuracy: 3 % of highest value. Over/under frequency level and delay: 45 .. 65 Hz, 1 .. 10 sec. Ambient temperature: -20 .. +70 oC. TE/1857/880462/10 Date of issue : 2010-02-02 Date of validity: 2015-02-01
Product: VOLTAGE RELAY Type: T3100 General technical data: Max. voltage: 660 VAC. Voltage range: 70 .. 120 %. Frequency range: 40 .. 400 Hz. Overall accuracy: 3 % of highest value. Over-voltage level, delay and hysteresis: 100 .. 120 %, 1 .. 10 sec., 1 .. 10 %. Under-voltage level, delay and hysteresis: 80 .. 100 %, 1 .. 10 sec., 1 .. 10 %. Ambient temperature: -20 .. +70 oC.
76 Volume "TE"
Siemens AG A&D CD
TE/1735/883235/08
Product: ACTUATOR SENSOR INTERFACE Type: Motor starter 3RK1321/22 Safety monitors 3RK1105 Power supply units 3RX93..-.., 3RX95..-..,4FD51..-..,4FD63..-..,6EP16..-.. Master 6GK1411-...,6GK1415-...,6GK1243-...,6GK7242-..., 6GK7342-..., 6ES7156-... Slave 3RG9..-..., 3RK1..-..., 3RK2..-..., 6GK1210..-... BERO (inductive, sonar, optical) 3RG4..-..., 3RG6..-..., 3RG7..-... Switches (position, pull-rope) 3SE2..-..., 3SE3..-..., 3SE7..-... Pushbutton switches and indicators 3SB3..-... Signalling column 8WD43..-... Touch panels 3SB4..-... Enclosure 3SB3801 up to 06 Gateways 3RK10...-..., 6GK1415-... ASI Standard module for enclosure 3SF5500. General technical data: See: SIEMENS LV 1T 2007 Catalogue & SIEMENS IK PI 2007 Catalogue
Siemens AG, I BT LV
TE/1891/880423/11
Product: SWITCHDISCONNECTORS (with or without fuses) Type: 3KA; 3KE; 3KL; 3KM; 3NP General technical data: Conventional enclosed thermal current: up to 1000 A Rated insulation voltage: 1000 V a.c.
Product: CIRCUIT BREAKERS Type: 3VF3 - 3VF8; 3WN General technical data:
Rated insulation voltage:690 V a.c. for 3VF3-3VF8, 3WN Rated current:16 - 2500 A for 3VF3-3VF8 630 - 6300 A for 3WN1 630 - 3200 A for 3WN6
TE/1893/880423/11
TE/1894/880423/11
Product: CIRCUIT BREAKER Type: 3VL17, 3VL27, 3VL37, 3VL47, 3VL57, 3VL67, 3VL77, 3VL87 Accessories 3VL9, 3TX4, 8US1 General technical data: As specified in Appendix to Type Approval Certificate No.TE/1894/880423/11.
Siemens AG, I IA CE
TE/1870/880423/10
Product:
78 Volume "TE"
TE/1871/880423/10
Product:
Product:
Product:
SIRIUS Innovation 3RT2.1, 3RT2.2, 3RH2 Accessories: 3RA27, 3RA28, 3RH29, 3RT19, 3RT29, 3RV29
General technical data:
Rated insulation voltage Ui: Ambient Temperature: Degree of protection: 690 V +60C IP20
TE/1880/880423/11
Product:
Volume "TE" 79
TE/1883/880423/11
Product:
Load Feeders
Type:
TE/1886/880423/11
TE/1888/880423/11
Product: CONTACTORS Type: 3TF6 General technical data: Conventional enclosed thermal current: Rated insulation voltage:
Product: SWITCHGEAR SYSTEM Type: 3RV Circuit Breakers & Accessories 3RT, 3RH, 3RA Contactors and Contactor Assemblies & Accessories 3RU Overload Relays & Accessories 3RN Thermistor Motor Protection & Accessories 3RP Time Relays & Accessories General technical data:
According to Siemens Catalogue LV10, 2004
Siemens Energy & Automation, Inc. 811 North Main Street 43311 OH Bellefontaine United States of America
TE/1895/880423/11
Product: CIRCUIT BREAKER Type: 3VL17, 3VL27, 3VL37, 3VL47, 3VL57, 3VL67, 3VL77, 3VL87 Accessories 3VL9, 3TX4, 8US1 General technical data:
As specified in Appendix to Type Approval Certificate No.TE/1895/880423/11.
TE/1790/883122/09
Product: DIGITAL PROTECTION RELAYS FOR GENERATORS, MOTORS, TRANSFORMERS AND POWER LINES Type: SYMAP-BC Series (BC, BCG) SYMAP-X Series (X, XG) SYMAP-Y Series (EC, ECG, F, G, M, T, LD)
Volume "TE" 81 General technical data: Rated voltage: 12-36 V DC, 36-72 V DC, 80-300 V DC or 60-230 V AC Enclosure protection: IP54 (front panel), IP10 (terminals) Operating temperature: -20...+70C
Telegraphs
FAMOR S.A. Kaszubska 25 85-048 Bydgoszcz Poland
TE/1780/880515/08
Product:
TELEGRAPH UNIT
Type:
ZC8006
General technical data: Supply voltage: Max. power consumption: Degree of enclosure protection: 24V DC 10W IP44
Transformers
ELHAND-Transformatory ul. PCK 22 42-700 Lubliniec Poland
TE/1962/880017/13
Product: 1PHASE AND 3PHASE DRY TRANSFORMERS Type: ET1oM, ET3oM, ET1SM, ET3SM
82 Volume "TE"
General technical data: Rated power: 0,05 up to 160,0 kVA Rated primary voltage: up to 1000 V Rated secondary voltage: up to 1000 V
mdexx GmbH
TE/1887/880423/11
Product: CONTROL TRANSFORMERS Type: TAM; TAT; TAW; TAV; General technical data:
Rated insulation voltage: 690 V a.c.
Siemens AG, I IA CE
TE/1910/880423/11
Product: CONTROL TRANSFORMERS Type: 4AM; 4AT; 4AW; 4AV; General technical data:
Rated insulation voltage: 690 V a.c.
Volume "TE" 83
TE/1945/883042/12
Product: POWER DISTRIBUTION MODULE Type: PDM-10 PDM-20 24V PDM-20 110V General technical data: Permissible ambient temperature range: -25 +85 C. Enclosure protection degree: IP30. Rated supply voltage (2 separate power inputs): 24VDC / 110VDC. Module functional details: power distribution, power supply fault monitoring, protection by fuses, protection against reversed polarity, EMC filtering, transient suppress, earth fault monitoring, current limitation, outputs voltage presence monitoring.
TE/1826/880590/09
Product:
Autopilots
Type:
NAVpilot-500/511/520/611/700
General technical data:
Power supply: 12 24 V DC, 3.0 A (excluding pump) 10 W with 1 control unit (excluding pump)
84 Volume "TE"
25 W with 6 control units (excluding pump) Environment: Temperature: -15 +55 (IEC 60945 test method) Waterproofing: IPX6 (Control Unit), Rudder Feedback Unit) IPX2 (Processor Unit) Intended for: 1. Non-Solas vessels except of: passenger ships engaged on domestic voyages, fishing vessels of 24 m in length and above. 2. Pleasure boats.
TE/1867/883045/10
Product: Bridge Navigational Watch Alarm System (BNWAS) Type: NavGard General technical data: System components: (1) Control panel Main supply voltage: 100 .. 240 VAC or/and 24VDC; emergency supply: 12V Ni-MH battery; enclosure protection degree: IP54; ambient temperature: -40 .. +70 oC. (2) PIR motion sensors directional/360 degree Supply voltage: 12VDC; ambient temperature: -10 .. +55 oC. (3) Reset push-buttons Supply voltage: 12VDC; ambient temperature: -40 .. +70 oC. (4) Sounders Supply voltage: 12VDC; ambient temperature: -25 .. +55 oC. (5) Beacons Supply voltage: 12VDC; ambient temperature: -25 .. +55 oC. Part code of each component: Console Assembly 101080, Push-button 101066, Vertical round sounder 101064, Ceiling 360 degrees PIR 101060, Wall mount PIR 101059, Beacon 101065; Wall Mount Assembly 101081, Push-button 101061, Square Sounder 101084, Ceiling 360 degrees PIR 101058, Sounder 101063, Beacon 101083, H-PIR 101062.
Volume "TE" 85
TE/1884/883045/11
TE/1732/815893/08
Product: OIL BURNERS & BURNER CONTROL PANELS Type: Oil burners: Type L, RL, M, MS, RM, RMS; Sizes 1, 3, 5-11, 30-70 Burner control panels: Type WS & WP
86 Volume "TE" General technical data: Burners: - Enclosure protection: IP 44 or IP 54. - Rated voltage: from 220 V AC to 400 V AC. Control panels: - Enclosure protection: dependent on protection degree of control and indicating devices mounted on the enclosure of the panel.
TE/1911/883045/11
Product: BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Type: EWAS 3.1 General technical data: System components: Bridge Navigational Watch Alarm System Control Panel Battery Back-Up Bridge Watch Reset Button Bridge Watch Back-Up Panel Bridge Watch Back-Up Panel (With Buzzer) Klaxon Pss-0089 Technical data:
Main Power Supply Emergency Power Supply Degree of protection: 24VDC 24VDC or Battery 12V 0.7Ah IP22
Selco A/S
TE/1849/880462/10
Volume "TE" 87 General technical data: Max. voltage: 660 VAC. Voltage range: 70 .. 110 %. Frequency range: 35 .. 70 Hz. Frequency difference: 0,1 .. 1,0 Hz. Voltage difference: 2 .. 10 %. C/B make time: 20 .. 200 msec. Ambient temperature: -20 .. +70 oC. TE/1850/880462/10 Date of issue : 2010-02-02 Date of validity: 2015-02-01
Product: LOAD SHARER Type: T4800 General technical data: Max. voltage: 660 VAC. Voltage range: 70 .. 110 %. Frequency range: 35 .. 70 Hz. Frequency adjustment: 48 .. 62 Hz. Proportional band: 50 .. 250 % load 5 .. 25 % frequency Dead band zone: 2 .. 10 % load 0,2 .. 1,0 % frequency Ambient temperature: -20 .. +70 oC. TE/1851/880462/10 Date of issue : 2010-02-02 Date of validity: 2015-02-01
Product: PARALLELING RELAY Type: T5000 General technical data: Max. voltage: 660 VAC. Voltage range: 70 .. 110 %. Frequency range: 45 .. 65 Hz. Voltage difference: 10 .. 15 %. Frequency difference: 0,15 .. 0,225 Hz. Phase difference: 6 .. 9 . Ambient temperature: -20 .. +70 oC.
88 Volume "TE"
TE/1944/883045/12
Product:
BNWAS
General technical data: System components: - Central Unit - Reset Unit - Cabin Unit - Data Recorder - Battery Back-Up Technical data:
Main Power Supply Emergency Power Supply Degree of protection: 24V DC Battery 18V IP22
TE/1955/883083/12
Volume "TE" 89 Enclosure protection degree: IP56. Part Nos.: 285-1138, 346-1903.