Reference project - Reliance Datacenter

Project
Location Industry Customer End user Total power available Year of installation At Vashi, Navi Mumbai, India Integrated Data Center(IDC) Reliance Industries Limited Reliance Industries - RCP 3.0 MVA (No Break) 2009

Project background
Reliance Industries demanded the highest possible level of security to achieve the maximum reliability and uptime for the mission critical servers and other crucial IT equipment to be hosted at its new Navi Mumbai facility. Reliance also required a Green solution that could deliver the desired level of power efficiency. The five story 2000 sqm datacenter built to accommodate the data halls is situated remotely, approximately 0.7 km from the critical power and cooling plant. The Navi Mumbai facility is also situated in an environmentally challenging location that experiences high temperatures, high humidity and heavy rainfall. The Diesel Rotary UPS (DRUPS) solution from Hitec Power Protection fully met the requirements of Reliance Industries as it provides a flexible and future-proof solution to accommodate the ever growing and expanding needs of Indias largest company. It is important to mention that during the evaluation process Hitec demonstrated to Reliance that its equipment had been specifically developed to meet the needs of the Indian market and that it would operate reliably and efficiently to deliver secure power to the critical IT and cooling loads. By combining Hitecs efficient, economic and environmentally conscious principles with the excellent after-sales support from Hitecs Indian partner Hi-Rel, Reliance has chosen the most suitable and effective power solutions for this facility.

Project requirements
The main objective was to design a datacenter facility to be Tier IV compliant. A Tier IV solution is the most resilient approach possible from the uptime institute and it demands the incorporation of duplicate and physically separate operating systems to ensure complete fault tolerance and concurrent maintainability (99.995% data hall uptime). To realize this Hitec installed two completely independent Medium Voltage Hitec diesel rotary UPS systems to a total resilience level of N+N. There is total system isolation up to the point of power delivery for 3 MVA of secure power. The stand alone fuel capacity of the system was required to be at least 72 hours. The project counted for many challenges one being the 30 meter high (chimney) exhaust system that would be needed for the individual DRUPS and connecting the vertical radiators to provide sufficient cooling air.

UPS room after installation

MV Switch panels and controls

Hitec solution
Tier IV system N+N system Mitsubishi diesel engines, type S16R-PTA (16 cylinders) Hitec Power Protection Induction Couplings AVK alternators 4 units x 1500 kVA Cross Link System 26 kV Medium Voltage switchgear Medium Voltage (MV) application, 11kV at 50 Hz Turnkey project with Hi-Rel Hitec partner in India - Project management & engineering - MV power & control cabling - Exhaust system (30m high) - Water cooling diesel engines with vertical radiators - Connection of vertical radiators - Fuel systems with daily 990l fuel day tank - UPS room ventilation

Off loading

Chimney installation (30 meters)

Completed piping, flues and power cabling

Key partners involved