COMMANDS.

Health Checkup 1. Allip:alcat=apz; 2. DTSTP:DIP=ALL,STATE=ABL; 3. C7LTP:LS=ALL; 4. TRRPP:MP=ALL; 5. TRDMP:MP=ALL; 6. NSSTP; 7. NSDAP; 8. GDCVP; 9. GSCVP; 10. DPWSP; 11.SYRIP:SURVEY; 12. SYELP; 13. GDSTP; 14. GSSTP; 15. SYBFP:FILE; 16. Dbtsp:tab=saactions; 17. Rlcrp:Cell=all; 18. Tpstp:sdip=all; 19. Pwnsp:sdip=all; 20. Ntstp:snt=all; 21. Rrgbp; Commands to check site. BSC. Commands to take backup of a BSC.

1. ALLIP:ALCAT=APZ; Function: This command Prints the ALARM LIST. Note: There should be no alarm in any site. Case: A1/APZ BSCRPR1_G10B 0425 Network Synchronization Fault REF 0ETM2, MS-0 STATE BLOC FCODE 1 130404 0629

Conclusion: There is a Network Sync. Fault in BSCRPR1, Status = Blocked. Case: A2/APZ BSCRPR1_GI0B 1692 130406 1016

Event Reporting Threshold Reached Enum 118 Threshold THI Level 10

Conclusion: The BSCs threshold limit is crossed.

2. DSTP:DIP=ALL,STATE=ABL; Function: DIGITAL PATH STATE Note: This command Prints the digital path means, the path of the cable. Case: DIP TYPE TIMBER IEX DEVBALD IEX RAWANBT IEX RAIP69 IEX MEDICAL IEX STATE LOOP TSLOTL DIPEND ABL ABL ABL ABL ABL FAULT AIS AIS AIS AIS AIS SECTION

Conclusion: All DIP connected other exchange, and in automatic block stage. Type: 1. PRA 2. IEX 3. REMUX 4. RSS 5. RSS910 6. RSM 7. TRI 8. MO 9. V5 State: 1. WO 2. MBL 3. ABL 4. CBL 5. TRAFLIM Working Manually Blocked Automatic Blocked Blocked from System Traffic limited (1-4 handling groups faulty) Primary Access. DIP connected to Other Exchange. DIP connected to Other Multiplexer. DIP connected to Remote Subscriber Stage. DIP connected to Multiple Access Group. DIP connected to Remote Subscriber Multiplex. DIP connected to Transmission Radio Interface. DIP connected to Managed Object. V5.2 connected DIP.

Fault: 1. LOF / LOS 2. ALL1 / AIS 3. RDI 4. ERATE / CSES 5. LOMF / REFM 6. AISM Failure in receive direction detected by local termination equipment. Alarm indication signal transmitted by remote end termination equipment due to failure up streams. Remote defect indication. Server degradation of signal. Faults related to multiframe signaling (TS16). Alarm indication signal in TS16 transmitted by remote end termination equipment due to failure affecting the signaling up streams.

3. C7LTP:LS=ALL; Function: CCITT7 Link Set State. Note: This command Prints the link set state for the specified link sets. Case: LS 3-802 3-9261 3-11703 3-11877 SPID RBSCBIL MSC MSCRPR1 BSCRGH 00 01 00 01 ACTIVE ACTIVE ACTIVE ACTIVE SLC STATE INHIBST FCODE INFO

Conclusion: The BSC is connected with RBSCBIL, MSC, MSCRPR1 & BSCRGH. From which MSCRPR1 & BSCRGH are Active, Both SLC should be Active. CCITT7 - International Telegraph and Telephone Consultative Committee signaling system number 7.

4. NSSTP; Function: Clock Reference State. Note: This command Prints the state of all connected Clock References. Case: REF 0ETM2, MS-0 1ETM2, MS-0 STATE SB EX BLS

Conclusion: Shows two external clocks. One is in Stand-by mode and another one is in Executed mode (on). At least one clock should be in EX mode.

5. NSDAP; Function: Clock Reference Supervision Data. Note: This command Prints the Supervision data for all defined clock-references in the Operating area. Case: AREA OPERATING STATIC DATA REF 0ETM2, MS-0 1ETM2, MS-0 CLREFINL 1 4 REFGRP 1 1 PRI 2 1 FDL WDL 5000 20 5000 20 ACL A1 A1

DYNAMIC DATA REF 0ETM2, MS-0 1ETM2, MS-0 Conclusion: Shows FD 0 0 WD 0 0

6. GDCVP; Function: Distributed Group Switch CLM Control Value. Note: This command Prints the control values and one hour average values in clock module.

Case: CLM OSCILLATOR CONTRVALUE CLM-0 CLM-1 0 1 0 1 32292 34894 33980 35305 AVERAGEVALUE 32228 34862 33980 35335 FAULTCASE

Conclusion: Shows two internal clocks. Each CLM has 2 oscillator 0,1 and shows control value and average value.

7. DPWSP; Function: CP state. Note: This command Prints the CP working state.

Case: MAU NRM SB B SBSTATE WO

Conclusion: Shows Node-B is in Stand-by state and is working. And Node-A is in EX (executed) state (ON).

8. SYRIP:SURVEY; Function: Software Recovery Survey. Note: This command Prints the Software recovery information. Case: EVENT TYPE EXPLANATION 24 FORLOPP FORLOPP RELEASE REQUESTED FROM APPL 22 FORLOPP FORLOPP RELEASE REQUESTED FROM APPL EVENTCNT FRDEL 0 3 3

EVENT CODE INF1 INF2 INF3 INF4 SIDE STATE DATE TIME ACT 24 H'3100 H'0146 H'0001 H'0000 H'0001 A-EX PARAL 130220 005950 NO 22 H'3100 H'0146 H'0001 H'0000 H'0000 A-EX PARAL 130220 005708 NO Conclusion: Shows the software error, its event and type. The second table shows its date and time of occurrence.

9. SYELP; Function: Limits for Software Error Intensity. Note: This command Prints the current error intensity and counters the limit.

Case: DCAT 0 1 2 3 4 TIME 0000 - 2359 0000 - 2359 0000 - 2359 0000 - 2359 0000 - 2359 LIMIT 40000 40000 40000 40000 40000

CURRENT ERROR LIMIT: 40000 CURRENT ERROR INTENSITY: 0 FORLOPP RELEASE DELAY LIMIT: 30 DELAY FOR LAST FORLOPP RELEASE: 0 NUMBER OF FORLOPPS DURING RELEASE: 0 Conclusion: Shows the Current error limit & Current error intensity.

10. GDSTP; Function: Distributed Group Switch State. Note: This command Prints the state of Distributed Group Switch Units.

Case: UNIT CLM-0 CLM-1 UNIT XM-A-0-0 XM-A-0-1 XM-A-0-2 XM-A-0-3 XM-A-0-4 XM-A-0-5 MUX34-A-0 MUX34-A-1 MUX34-A-8 MUX34-A-9 STATE WO WO STATE WO WO WO WO WO WO WO WO WO WO BLSTATE BLSTATE VAR 11 11 VAR 1 1 1 1 1 1 0 0 0 0 STATUS SLAVE MASTER UNIT XM-B-0-0 XM-B-0-1 XM-B-0-2 XM-B-0-3 XM-B-0-4 XM-B-0-5 MUX34-B-0 MUX34-B-1 MUX34-B-8 MUX34-B-9 STATE WO WO WO WO WO WO WO WO WO WO BLSTATE

Conclusion: Shows that both the CLM are in Working state, and one is Master and the other one is Slave. The second table shows different devices attached with the BSC and their state.

11. SYBFP:FILE; Function: System Backup Files. Note: This command Prints, what date and time the different parts of the system backup copy have been output, which exchange identity, from what device the information has been read, what parts are current for reload, and the associated command log subfile (s).. Case: FILE RELFSW0 SUBFILE R1 R2 R3 R4 R5 IO EXCHANGE BSCRPR1_G10B CURRENT COMMANDLOG YES NO YES 0003431 NO 0003432 YES -

TYPE OUTPUTTIME DSSMALL 130416 0201 DSSMALL 130415 1701 DSLARGE 130415 1649 DSLARGE 130416 0201 PS, RS 130415 1649

Conclusion: Shows the backup files present in the RELFSW0 folder also its date and time.

12. DBTSP:TAB=SAACTIONS; Function: Database Table. Note: This command Prints the database table. Case: BLOCK SAFTAB1 TAB SAACTIONS TABLE WRAPPED YES

Conclusion: Shows

13. RLCRP:CELL=ALL; Function: Cell Resources. Note: This command Prints the cell resources, all the cells covered by the BSC. Case: CELL BCCH BIJUR1C 1 BIJUR1B 1 BIJUR1A 1 URGAR1C 1 URGAR1B 1 URGAR1A 1 LNCO3C 1 LNCO3B 1 LNCO3A 1 NONBR1C 1 NONBR1B 1 NONBR1A 1 PCMRB1C 1 PCMRB1B 1 PCMRB1A 1 KUKAR1C 1 CBCH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SDCCH 31 31 15 39 31 39 39 39 39 39 31 23 63 63 63 15 NOOFTCH 11- 22 11- 22 13- 26 26- 52 11- 22 26- 52 26- 52 26- 52 26- 52 26- 52 11- 22 12- 24 23- 46 23- 46 23- 46 13- 26 QUEUED 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Conclusion: Shows all the cells. BCCH (Broadcasting Channel) & CBCH should be 1.

14. TPSTP:SDIP=ALL; Function: Synchronous Digital Path State. Note: This command Prints the Synchronous Digital Path State. Case: SDIP LAYER K L M STATE 0ETM2 WO MS-0 WO MS-1 WO VC4-0 WO VC12-ALL WO SDIP LAYER LST 0ETM2 MS-0 MS-1 STANDBY BLS FAULT TYPE PL/TTI

ERDIINFO

Conclusion: Shows .

15. PWNSP:SDIP=ALL; Function: Protection Switching Network Protection State Details. Note: This command Prints the . Case: SDIP 0ETM2 1ETM2 2ETM2 3ETM2 4ETM2 11ETM2 13ETM2 14ETM2 MS MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 MS-0 MS-1 STATE WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO LST STANDBY STANDBY STANDBY STANDBY STANDBY STANDBY STANDBY STANDBY

Conclusion: Shows SDIP their state and mode. It shows SDIP is working or not.

16. NTSTP:SNT=ALL; Function: Switching Network Terminal (SNT) State. Note: This command Prints the state of the switching network terminal (SNT). Case: SNT ETRALT-1 ETRALT-2 ETRALT-3 ETRALT-4 ETRALT-5 RHSNT-0 RHSNT-1 RHSNT-2 STATE WO WO WO WO WO WO WO WO BLS LST FCODE

Conclusion: It shows different cards defined in the BSC and also shows their state whether it is working or not.

BASIC COMMANDS TO CHECK SITE

# If T.G. is unknown & OSS is down.


* Command: rlcrp:cell=all; Note: From this command we will get the cell i.d. Result: CELL BIJUR1C BIJUR1B BCCH CBCH SDCCH NOOFTCH 1 1 31 11- 22 1 1 31 11- 22 QUEUED 0 0

Copy this Cell i.d. and paste here

* Command: rxtcp:moty=rxotg,cell= BIJUR1B ; Note: From this command we will get the T.G. No. Result: MO RXOTG-495 CELL BIJUR1B CHGR 0

This is the required T.G. No.

# How to check the site name.


* Command: rxmop:mo=RXOTG-495; Note: From this command we can find out the site name. Result: MO RXOTG-495 RSITE BIJAPUR_I_SHD COMB FHOP MODEL HYB SY G12

This is the name of the site.

# How to check site Up/Down.


* Command: rxmsp:mo= RXOTG-495,subord; Note: From this command we can find whether the site is Operational or not. Result: MO STATE RXOTG-495 OPER RXOCF-495 OPER RXOIS-495 OPER RXOCON-495 OPER Conclusion STATE CONF NOOP ENA OP ENA OP Unconfig Site Down Up Down BLSTATE BLO 0000 0000 0000 0000 BLA 0000 0000 0000 0000 LMO BTS STA STA DIS DIS CONF CONF CONF

If CF is Fail :
* Command: rxbli:mo=rxocf-495; ; rxble:mo=rxocf-495; ;

If TRX is Fail :
* Command: rxbli:mo=rxotrx-495-0 &&-11; ; rxble:mo=rxotrx-495-0 &&-11; ;

If any 1 TRX is NOOP :


* Command: rxbli:mo=rxots-495-4-0; ; rxble:mo=rxots-495-4-0; {Copy this from the list of rxmsp command}

# How to check Abis Path Status (E-1).


* Command: rxapp:mo=rxotg-495; Result: MO RXOTG-495 DEV RBLT-705 RBLT-706 DCP 1 2 APUSAGE CONC MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 APSTATE TRXC SIGNAL SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA 64K NO NO NO NO NO NO TEI 4 5

RBLT-707

Copy any 1 device out of the first 31 devices which are defined for E-1 and paste here
* Command: radep:dev= RBLT-707;

BSCs

Old BSC

New BSC

S.No. 1 2 3 4 5 6 7 8 9

Name of Bsc BSCRPR1 BSCRPR2 BSCRPR3 BSCRPR4 BSCAMB1 RBSCDHAMTARI RBSCBHILAI RBSCBIL2 RBSCCHAMPA

I.P. addr. S.No.


10.2.37.95 10.2.37.100 10.2.37.112 10.2.37.205 10.2.37.202 10.2.37.92 10.2.37.105 10.2.39.22 10.2.37.242

Name of Bsc BSCRPR5 BSCRPR6 BSCRPR7 BSCRPR8


RBSCMAHASAMUND

I.P. addr.
10.2.37.82 10.2.37.135 10.228.171.37 10.228.171.52 10.2.37.132 10.2.37.126 10.228.171.68

10 11 12 13 14 15 16 17

BSCAMB2 RBSCBIL1 RBSCRAIGARH

COMMANDS TO TAKE BACKUP OF A BSC

Backup of CP.
Old BSC
* Command: Sybue; ; Sybup:file; ; Sytuc; ; Sybui:disc; ;

New BSC
Sybue; ; Sybup:file; ; Sytuc; ; Sybui:disc; ;

* Backup of old BSC Stored at: L/FMS/DATA/CPF/RELVOLUMSW/RELFSW0

* Backup of new BSC Stored at: K/FMS/DATA/CPF/RELVOLUMSW/RELFSW0