You are on page 1of 9

DWDM 80km SFP+ Transceiver

TPD1XGKZRCxxG
Product Description
The TPD1XGKZRxxG is an enhanced small form factor pluggable (SFP+) fiber optic transceiver with digital diagnostics monitoring functionality (DDM). Supporting Ethernet and Fiber Channel standards with dense wavelength division multiplexing (DWDM) wavelength makes it ideally suited for high capacity data-com and storage area network applications. DDM functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) SFF-8472, Rev. 10.4. Each transceiver utilizes an electro absorption modulator integrated laser (EML) with an operating wavelength with 100GHz (0.8nm) spacing per the ITU-grid. The transceiver supports data rates ranging from 11.3Gbps down to 8Gbps. It provides an excellent solution for data transmission at DWDM wavelength over up to 80km single mode fiber. The low power consumption and excellent EMI performance enable system design with high port density. The product is RoHS compliant and is designed and tested in accordance with industry safety standards. The transceiver is Class I Laser product per U.S. FDA/CDRH and international IEC-60825 standards. The TPD1XGKZRCxxG transceiver connects to standard 20-pad SFP+ connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different transceivers without removing the power supply from the host system. The transmitter and receiver DATA interfaces are internally AC-coupled. LV-TTL Transmitter Disable control input and Loss of Signal (LOS) output interfaces are also provided. The transceiver has bail-type latch, which offers an easy and convenient way to release the modules. The latch is compliant with the SFP MSA. The transceiver operates from a single +3.3V power supply over an operating case temperature range of 5C to +70C (commercial), or -5C to +85C (extended) or -40C to +85C (industrial). The housing is made of metal for EMI immunity.

Pb

Features Temperature-stablized DWDM EML transmitter Transmission distance up to 80km (SM Fiber) Low power consumption Wide case operating temperature range Compliant to SFP+ Electrical MSA SFF-8431 Compliant to SFP+ Mechanical MSA SFF-8432 Digital Diagnostics Monitoring (DDM) through Serial Interface comply with SFF-8472, Rev. 10.4 RoHS 6/6 compliant Laser Class 1 IEC/CDRH compliant

Absolute Maximum Ratings

Storage Temperature Range

Operating Case Temperature Operating Relative Humidity Supply Voltage Range


1

Preliminary
TST - 40 -5 -5 0 + 85 Commercial Extended Industrial + 70
1

Parameter

Symbol

Minimum

Maximum

Units C C C C % V

TOP

+ 85 85

- 40

+ 85

RH VCC

- 0.5

+ 3.6

Measured on top side of SFP+ module at the front center vent hole of the cage. 2 Non condensing

An Oplink Company

S0252. Rev.03. 2012-01-09

TPD1XGKZRCxxG
Transmitter Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Parameter Data Rate Center Wavelength Extinction Ratio Relative Intensity Noise Side Mode Suppression Ratio Optical Return Loss Tolerance Optical Output Eye
1

Symbol B C PAvg ER RIN SMSR -

Minimum 0 8.2 30 -

Typical 10.3125

Maximum +5 - 128 - 21

Units Gb/s nm dBm dB dB/Hz dB dB

See Ordering Information Table Compliant with IEEE 802.3ae

Average Optical Output Power

BOL : 0.05nm from ITU grid; EOL: 0.1nm from ITU grid.

Receiver Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Parameter Data Rate Wavelength of Operation Receiver Sensitivity @ 10.3125Gb/s Maximum Input Optical Power (10 Receiver Reflectance LOS Hysteresis LOS Thresholds
1

Symbol B
1 1

Minimum 1530 -8 0.5 - 38

Typical 10.3125 -

Maximum 1565 - 23 - 20 - 27 - 25 -

Units Gb/s nm dBm dBm dBm dB dB dBm

Pmin_BB Pmin_Fiber Pmax BER)

Receiver Sensitivity with 80km Fiber@10.3125Gb/s


-12

Increasing Light Input Decreasing Light Input

Plos+ Plos-

Specified with BER <1x10-12 and PRBS 2 31-1.

Note: The specified characteristics are met within the recommended range of operation. Unless otherwise noted typical data are quoted at nominal voltage and +25C ambient temperature.

Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.

Oplink Communications, Inc.


DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements

Oplink Communications, Inc

S0252. Rev.03. 2012-01-09

TPD1XGKZRCxxG
Transmitter Electrical Characteristics
Parameter Differential Input Impedance Differential Input Voltage Swing Input HIGH Voltage (TX Disable) 1 Input LOW Voltage (TX Disable) Output HIGH Voltage (TX Fault)
1 2

(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Minimum 180 2.0 0 2.0 0 Typical 100 Maximum 700 VCC 0.8 VCC + 0.3 0.8 Units mV V V V V

Symbol Zd VPP-DIFF VIH VIL VOH VOL

1 2

Output LOW Voltage (TX Fault) 2

There is an internal 4.7k to 10k pull-up resistor to VccT. Open collector compatible, 4.7k to 10k pull-up resistor to Vcc (Host Supply Voltage).

Receiver Electrical Interface (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Parameter Differential Output Impedance Differential Output Swing Output Rise and Fall time (20% to 80%) Output HIGH Voltage (LOS) Output LOW Voltage (LOS)
1

Symbol Zd VPP-DIFF tRH, tFH VOH VOL

Minimum 300 28 VCC - 1.3 0

Typical 100 -

Maximum 850 VCC + 0.3 0.8

Units mV ps V V

1 1

Open collector compatible, 4.7k to 10k pull-up resistor to Vcc (Host Supply Voltage).

Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Parameter Power Supply Voltage DC Common Mode Voltage Supply Current Power Consumption Symbol VCC VCM IVCC PW Minimum 3.13 0 Typical 3.30 365 1.2 Maximum 3.47 3.60 Units V V mA W

Note: The specified characteristics are met within the recommended range of operation. Unless otherwise noted typical data are quoted at nominal voltage and +25C ambient temperature.

Connector Pin-out
VEER

10 9 8 7 6 5 4 3 2 1

11 12 13 14 15

VEER RDRD+ VEER VCCR VCCT VEET TD+ TDVEET

RS1 RX_LOS RS0 MOD-ABS SCL SDA TX_DISABLE TX_FAULT VEET

TOWARD HOST

16 17 18 19 20

TOWARD BEZEL

Oplink Communications, Inc

S0252. Rev.03. 2012-01-09

TPD1XGKZRCxxG
Module Pin Description
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2

Logic LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I/O LVTTL-I LVTTL-O LVTTL-I CML-O CML-O CML-I CML-I -

Symbol VeeT TX_Fault TX_Disable SDA SCL MOD-ABS RS0 RX_LOS RS1 VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT

Description Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output 2-Wire Serial Interface Data Line 2-Wire Serial Interface Clock Module Definition, Grounded in the module No function implemented Receiver Loss of Signal Indication No function implemented Module Receiver Ground Module Receiver Ground Receiver Inverted Data Output Receiver Data Output Module Receiver Ground Module Receiver 3.3V Supply Module Transmitter 3.3V Supply Module Transmitter Ground Transmitter Non-Inverted Data Input Transmitter Inverted Data Input Module Transmitter Ground

Module ground pins GND are isolated from the module case Shall be pulled up with 4.7k-10k to a voltage between 3.15V and 3.45V on the host board

Application Notes Electrical Interface: All signal interfaces are compliant with the SFP+ MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7k - 10k resistor on the host board. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up with a 4.7k - 10k resistor on the host board. TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled. The laser is also disabled if this line is left floating, as it is pulled high inside the transceiver. Serial Identification and Monitoring: The module definition of SFP is indicated by the MOD_ABS pin and the 2-wrie serial interface. Upon power up, the 2-wrie interface appears as NC (no connection), and MOD_ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the device that are not write protected, and the negative edge clocks data from the device. The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter power, average receiver signal, all alarms and warnings, and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 10.4. Power Supply and Grounding: The power supply line should be well-filtered. All power supply bypass capacitors should be as close to the transceiver module as possible.

Oplink Communications, Inc

S0252. Rev.03. 2012-01-09

TPD1XGKZRCxxG
Interfacing the Transceivers
Communication is via a serial 2-wire serial interface. As described in the document SFF-8472 (REV. 10.4) there are two distinct address spaces:
Base Address A0(hex)
Byte Address Content Byte Address

Base Address A2(hex)


Content

0 95 96 127 128 255

Serial Transceiver ID as defined in SFP MSA OPLINK Specific Reserved

0 - 55 56 - 95 96 119 120 127 128 247 248 - 255

Alarm & Warnings thresholds & limits External calibration constants (not used) Values from real time diagnostic monitoring Not used Customer specific, writable area Not used

Application Schematics

Recommended electrical connections to transceiver are shown below.

TD+

50 line 50 line 50 line 50 line ASIC/ SerDes +3.3V R +3.3V R +3.3V R

4.7H

+3.3V

0.1F

22F

0.1F

VccR

TDRD+

4.7H

+3.3V

0.1F

22F

0.1F

VccT

RD-

SFP+

SCL, SDA, MOD_ABS TX_Fault RX_LOS

VeeT, VeeR

R: 4.7k to 10k

ESD & Electromagnetic Compatibility


Requirements Standard Status

Electro Static Discharge to the Electrical Pins (ESD) Immunity to ESD (housing, receptacle)

EIA/JESD22-A114-B MIL-STD 883C Method 3015.7 IEN 61000-4-2 FCC Part 15, Class B EN 55022 Class B CISPR 22

Exceeds requirements Class 1B (>1000V) Exceeds requirements Discharges ranging from 2kV to 15kV without damages to the transceiver Exceeds requirements Class B

Electromagnetic Emission (EMI)

Oplink Communications, Inc

S0252. Rev.03. 2012-01-09

TPD1XGKZRCxxG
Package Outline

Dimensions in [inches] mm Millimeters are the primary units. Tolerances are in accordance with SFF-8432 Rev.5

Ordering Information

Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplinks Sales and Marketing for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.
Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance

TPD1XGKZRC00061G TPD1XGKZRC00060G TPD1XGKZRC00059G TPD1XGKZRC00058G TPD1XGKZRC00057G TPD1XGKZRC00056G TPD1XGKZRC00055G TPD1XGKZRC00054G TPD1XGKZRC00053G TPD1XGKZRC00052G TPD1XGKZRC00051G TPD1XGKZRC00050G TPD1XGKZRC00049G TPD1XGKZRC00048G TPD1XGKZRC00047G TPD1XGKZRC00046G TPD1XGKZRC00045G

- 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C

Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial

1528.77 1529.55 1530.33 1531.12 1531.90 1532.68 1533.47 1534.25 1535.04 1535.82 1536.61 1537.40 1538.19 1538.98 1539.77 1540.56 1541.35

196.1 196.0 195.9 195.8 195.7 195.6 195.5 195.4 195.3 195.2 195.1 195.0 194.9 194.8 194.7 194.6 194.5

61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45

80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km
S0252. Rev.03. 2012-01-09

Oplink Communications, Inc

TPD1XGKZRCxxG
Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance

TPD1XGKZRC00044G TPD1XGKZRC00043G TPD1XGKZRC00042G TPD1XGKZRC00041G TPD1XGKZRC00040G TPD1XGKZRC00039G TPD1XGKZRC00038G TPD1XGKZRC00037G TPD1XGKZRC00036G TPD1XGKZRC00035G TPD1XGKZRC00034G TPD1XGKZRC00033G TPD1XGKZRC00032G TPD1XGKZRC00031G TPD1XGKZRC00030G TPD1XGKZRC00029G TPD1XGKZRC00028G TPD1XGKZRC00027G TPD1XGKZRC00026G TPD1XGKZRC00025G TPD1XGKZRC00024G TPD1XGKZRC00023G TPD1XGKZRC00022G TPD1XGKZRC00021G TPD1XGKZRC00020G TPD1XGKZRC00019G TPD1XGKZRC00018G TPD1XGKZRC00017G TPD1XGKZRC00016G

- 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C - 5C to +70C

Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial

1542.14 1542.94 1543.73 1544.53 1545.32 1546.12 1546.92 1547.72 1548.51 1549.32 1550.12 1550.92 1551.72 1552.52 1553.33 1554.13 1554.94 1555.75 1556.55 1557.36 1558.17 1558.98 1559.79 1560.61 1561.42 1562.23 1563.05 1563.86 1564.68

194.4 194.3 194.2 194.1 194.0 193.9 193.8 193.7 193.6 193.5 193.4 193.3 193.2 193.1 193.0 192.9 192.8 192.7 192.6 192.5 192.4 192.3 192.2 192.1 192.0 191.9 191.8 191.7 191.6

44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km

Model Name

Operating Temperature

Center Wavelength (nm)

ITU Frequency (THz)

Wavelength Reference

Distance

TPD1XGKZRE00061G TPD1XGKZRE00060G TPD1XGKZRE00059G TPD1XGKZRE00058G TPD1XGKZRE00057G TPD1XGKZRE00056G TPD1XGKZRE00055G TPD1XGKZRE00054G TPD1XGKZRE00053G TPD1XGKZRE00052G TPD1XGKZRE00051G

- 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C

Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended

1528.77 1529.55 1530.33 1531.12 1531.90 1532.68 1533.47 1534.25 1535.04 1535.82 1536.61

196.1 196.0 195.9 195.8 195.7 195.6 195.5 195.4 195.3 195.2 195.1

61 60 59 58 57 56 55 54 53 52 51

80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km
S0252. Rev.03. 2012-01-09

Oplink Communications, Inc

TPD1XGKZRCxxG
Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance

TPD1XGKZRE00050G TPD1XGKZRE00049G TPD1XGKZRE00048G TPD1XGKZRE00047G TPD1XGKZRE00046G TPD1XGKZRE00045G TPD1XGKZRE00044G TPD1XGKZRE00043G TPD1XGKZRE00042G TPD1XGKZRE00041G TPD1XGKZRE00040G TPD1XGKZRE00039G TPD1XGKZRE00038G TPD1XGKZRE00037G TPD1XGKZRE00036G TPD1XGKZRE00035G TPD1XGKZRE00034G TPD1XGKZRE00033G TPD1XGKZRE00032G TPD1XGKZRE00031G TPD1XGKZRE00030G TPD1XGKZRE00029G TPD1XGKZRE00028G TPD1XGKZRE00027G TPD1XGKZRE00026G TPD1XGKZRE00025G TPD1XGKZRE00024G TPD1XGKZRE00023G TPD1XGKZRE00022G TPD1XGKZRE00021G TPD1XGKZRE00020G TPD1XGKZRE00019G TPD1XGKZRE00018G TPD1XGKZRE00017G TPD1XGKZRE00016G

- 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C - 5C to +85C

Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended Extended

1537.40 1538.19 1538.98 1539.77 1540.56 1541.35 1542.14 1542.94 1543.73 1544.53 1545.32 1546.12 1546.92 1547.72 1548.51 1549.32 1550.12 1550.92 1551.72 1552.52 1553.33 1554.13 1554.94 1555.75 1556.55 1557.36 1558.17 1558.98 1559.79 1560.61 1561.42 1562.23 1563.05 1563.86 1564.68

195.0 194.9 194.8 194.7 194.6 194.5 194.4 194.3 194.2 194.1 194 193.9 193.8 193.7 193.6 193.5 193.4 193.3 193.2 193.1 193 192.9 192.8 192.7 192.6 192.5 192.4 192.3 192.2 192.1 192 191.9 191.8 191.7 191.6

50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km

Model Name

Operating Temperature

Center Wavelength (nm)

ITU Frequency (THz)

Wavelength Reference

Distance

TPD1XGKZRI00061G TPD1XGKZRI00060G TPD1XGKZRI00059G TPD1XGKZRI00058G TPD1XGKZRI00057G

- 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C

Industrial Industrial Industrial Industrial Industrial

1528.77 1529.55 1530.33 1531.12 1531.90

196.1 196.0 195.9 195.8 195.7

61 60 59 58 57

80km 80km 80km 80km 80km


S0252. Rev.03. 2012-01-09

Oplink Communications, Inc

TPD1XGKZRCxxG
Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference

Model Name

Operating Temperature

Distance

TPD1XGKZRI00056G TPD1XGKZRI00055G TPD1XGKZRI00054G TPD1XGKZRI00053G TPD1XGKZRI00052G TPD1XGKZRI00051G TPD1XGKZRI00050G TPD1XGKZRI00048G TPD1XGKZRI00049G TPD1XGKZRI00047G TPD1XGKZRI00046G TPD1XGKZRI00045G TPD1XGKZRI00044G

- 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C - 40C to +85C

Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial

1532.68 1533.47 1534.25 1535.04 1535.82 1536.61 1537.40 1538.98 1538.19 1539.77 1540.56 1541.35 1542.14 1542.94 1543.73 1544.53 1545.32 1546.12 1546.92 1547.72 1548.51 1549.32 1550.12 1550.92 1551.72 1552.52 1553.33 1554.13 1554.94 1555.75 1556.55 1557.36 1558.17 1558.98 1559.79 1560.61 1561.42 1562.23 1563.05 1563.86 1564.68

195.6 195.5 195.4 195.3 195.2 195.1 195.0 194.8 194.9 194.7 194.6 194.5 194.4 194.3 194.2 194.1 194.0 193.9 193.8 193.7 193.6 193.5 193.4 193.3 193.2 193.1 193.0 192.9 192.8 192.7 192.6 192.5 192.4 192.3 192.2 192.1 192.0 191.9 191.8 191.7 191.6

56 55 54 53 52 51 50 48 49 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km 80km

46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com www.oplink.com

TPD1XGKZRI00043G TPD1XGKZRI00042G TPD1XGKZRI00041G TPD1XGKZRI00040G TPD1XGKZRI00039G TPD1XGKZRI00038G TPD1XGKZRI00037G TPD1XGKZRI00036G TPD1XGKZRI00035G TPD1XGKZRI00034G TPD1XGKZRI00033G TPD1XGKZRI00032G TPD1XGKZRI00031G TPD1XGKZRI00030G TPD1XGKZRI00029G TPD1XGKZRI00028G TPD1XGKZRI00027G TPD1XGKZRI00026G TPD1XGKZRI00025G TPD1XGKZRI00024G TPD1XGKZRI00023G TPD1XGKZRI00022G TPD1XGKZRI00021G TPD1XGKZRI00020G TPD1XGKZRI00019G TPD1XGKZRI00018G TPD1XGKZRI00017G TPD1XGKZRI00016G

Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. 2012, Oplink Communications, Inc.

S0252. Rev.03. 2012-01-09