The Site Master is a handheld cable and antenna analyzer designed for installers, contractors, and wireless service providers who need a portable and rugged cable and antenna analyzer. It is designed for measuring Return Loss, VSWR, Cable Loss, of cable and antenna systems from 25 MHz to 4 GHz. Integrated Distance-To-Fault measurement can be used to locate the precise location of a fault within the feedline system. Options available with the S331D include High Accuracy Power Meter (Option 19) and Power Monitor (Option 5). The Site Master is capable of up to 1.5 hours of continuous operation from a fully charged field-replaceble battery and can be operated from a 12.5 Vdc source. Built-in energy conservation features can be used to extend the battery life. A standard 640*480 color TFT display provide graphic indications of various measurements. The displayed trace can be scaled or enhanced with frequency markers and limit lines. A menu option provides for an audible "beep" when the limit value is exceeded.

1-1

Standard Accessories
The Handheld Software Tools and Master Software Tools PC-based software programs provide a database record for storing measurement data. Software Tools can also convert the Site Master display to a Microsoft Windows_ workstation graphic. Measurements stored in the Site Master internal memory can be downloaded to the PC using the included null-modem serial cable. Once stored, the graphic trace can be displayed, scaled, or enhanced with markers and limit lines. Historical graphs can be overlaid with current data, and underlying data can be extracted and used in spreadsheets or for other analytical tasks. The Handheld Software Tools program can display measurements made with the Site Master (SWR, return loss, cable loss, distance-to-fault) as well as providing other functions, such as converting display modes and Smith charts. Refer to Chapter 7, Handheld Software Tools, for more information. The following items are supplied with the basic hardware: _ 65717 Soft Carrying Case _ 633-27 Rechargeable Battery, Ni-MH _ 40-168-R ACDC Adapter _ 806-141 Automotive Cigarette Lighter 12 Volt DC Adapter _ 2300-347 Handheld Software Tools CDROM _ 800-441 Serial Interface Cable (null modem type) _ 551-1691-R USB to RS-232 Adapter Cable _ 10580-00079 S331D Site Master User's Guide _ One-Year Warranty

Options
_ Option _ Option

5 Power Monitor - Requires external detector 19 High Accuracy Power Meter (sensor not included)

1-2
Chapter 1 General Information

External Detectors
The following Anritsu detectors can be used with the Site Master S331D when equipped with Option 5, Power Monitor.
Model Frequency Range Impedance Return Loss Input Conn. Frequency Response

5400-71N50 0.001 to 3 GHz 50_ 26 dB N(m) _0.2 dB, <1 GHz _0.3 dB, <3 GHz 5400-71N75 0.001 to 3 GHz 75_ 26 dB, <2 GHz 20 dB, <3 GHz N(m) _0.2 dB, <1 GHz _0.5 dB, <3 GHz 560-7N50B 0.01 to 20 GHz 50_ 15 dB, <0.04 GHz 22 dB, <8.00 GHz 17 dB, <18.0 GHz 14 dB, <20.0 GHz N(m) _0.5 dB, <18 GHz _1.25 dB, <20 GHz 560-7S50B 0.01 to 20 GHz 50_ 15 dB, <0.04 GHz 22 dB, <8.00 GHz 17 dB, <18.0 GHz 14 dB, <20.0 GHz WSMA (m) _0.5 dB, <18 GHz _2.0 dB, <20 GHz 560-7K50 0.01 to 40 GHz 50_ 12 dB, <0.04 GHz 22 dB, <8.00 GHz 17 dB, <18.0 GHz 15 dB, <26.5 GHz 14 dB, <32.0 GHz 13 dB, <40.0 GHz K(m) _0.5 dB, <18 GHz _1.25 dB, <26.5 GHz _2.2 dB, <32 GHz _2.5 dB, <40 GHz 560-7VA50 0.01 to 50 GHz 50_ 12 dB, <0.04 GHz 19 dB, <20.0 GHz 15 dB, <40.0 GHz 10 dB, <50.0 GHz V(m) _0.8 dB, <20 GHz _2.5 dB, <40 GHz _3.0 dB, <50 GHz

1-3
Chapter 1 General Information

Optional Accessories
Part Number Description Calibration Components ICN50B InstaCal Calibration Module, 2 MHz to 6.0 GHz, N(m), 50_ OSLN50-1 Precision Open/Short/Load, DC to 6 GHz, 42 dB, 50_, N(m) OSLNF50-1 Precision Open/Short/Load, DC to 6 GHz, 42 dB, 50_, N(f) 22N50 Open/Short, DC to 18 GHz, N(m), 50_ SM/PL-1 Precision Load, DC to 6 GHz, 42 dB, N(m), 50_ 22NF50 Open/Short, DC to 18 GHz, N(f), 50_ SM/PLNF-1 Precision Load, DC to 6 GHz, 42 dB, N(f), 50_ 2000-1618-R Precision Open/Short/Load, DC to 6 GHz, 7/16 DIN(m), 50_ 2000-1619-R Precision Open/Short/Load, DC to 6 GHz, 7/16 DIN(f), 50_ 22N75 Open/Short, DC to 3 GHz, N(m) 75_

26N75A Precision Termination, DC to 3 GHz, N(m) 75_ 22NF75 Open/Short, DC to 3 GHz, N(f) 75_ 26NF75A Precision Termination, DC to 3 GHz, N(f) 75_ 12N50-75B Matching Pad, DC to 3 GHz, 50 O to 75_ Precision Adapters 34NN50A Precision Adapter, N(m)-N(m), DC to 18 GHz, 50_ 34NFNF50 Precision Adapter, N(f)-N(f), DC to 18 GHz, 50_ Adapters 1091-26-R Adapter, N(m)-SMA(m), DC to 18 GHz, 50_ 1091-27-R Adapter, N(m)-SMA(f), DC to 18 GHz, 50_ 1091-80-R Adapter, N(f)-SMA(m), DC to 18 GHz, 50_ 1091-81-R Adapter, N(f)-SMA(f), DC to 18 GHz, 50_ 1091-172 Adapter, N(m)-BNC(f), DC to 1.3 GHz, 50_ 510-90-R Adapter, 7/16 DIN(f)-N(m), DC to 7.5 GHz, 50_ 510-91-R Adapter, 7/16 DIN(f)-N(f), DC to 7.5 GHz, 50_ 510-92-R Adapter, 7/16 DIN(m)-N(m), DC to 7.5 GHz, 50_ 510-93-R Adapter, 7/16 DIN(m)-N(f), DC to 7.5 GHz, 50_ 510-96-R Adapter, 7/16 DIN(m)-7/16 DIN(m), DC to 7.5 GHz, 50_ 510-97-R Adapter, 7/16 DIN(f)-7/16 DIN(f), DC to 7.5 GHz, 50_ Adapters w/ Reinforced Grip 1091-379-R Adapter w/ Reinforced Grip, 7/16 DIN(f)-7/16 DIN(f), DC to 6 GHz, 50_

1-4
Chapter 1 General Information
Test Port Cables, Armored 15NN50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-N(m), 6 GHz, 50_ 15NN50-3.0C Test Port Cable Armored, 3.0 meters, N(m)-N(m), 6 GHz, 50_ 15NNF50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-N(f), 6 GHz, 50_ 15NNF50-3.0C Test Port Cable Armored, 3.0 meters, N(m)-N(f), 6 GHz, 50_ Test Port Cables, Armored w/ Reinforced Grip 15RNFN50-1.5-R Test Port Cable Armored w/Reinforced Grip 1.5 meters, N(m)-N(f), 6 GHz, 50_ 15RNFN50-3.0-R Test Port Cable Armored w/Reinforced Grip 3.0 meters, N(m)-N(f), 6 GHz, 50_ 15RDFN50-1.5-R Test Port Cable Armored w/Reinforced Grip 1.5 meters, 7/16 DIN(f)-N(m), 6 GHz, 50_ 15RDFN50-3.0-R Test Port Cable Armored w/Reinforced Grip 3.0 meters, 7/16 DIN(f)-N(m), 6 GHz, 50_ 15RDMN50-1.5-R Test Port Cable Armored w/Reinforced Grip 1.5 meters, 7/16 DIN(m)-N(m), 6 GHz, 50_ 15RDMN50-3.0-R Test Port Cable Armored w/Reinforced Grip 3.0 meters, 7/16 DIN(m)-N(m), 6 GHz, 50_ Attenuators 3-1010-119 Attenuator, 10 dB, 2W, DC to 6 GHz 3-1010-122 Attenuator, 20 dB, 5W, DC to 12.4 GHz, N(m)-N(f) 42N50-20 Attenuator, 20 dB, 5W, DC to 18 GHz, N(m)-N(f) 3-1010-123 Attenuator, 30 dB, 50W, DC to 8.5 GHz, N(m)-N(f) 42N50A-30 Attenuator, 30 dB, 50W, DC to 18 GHz, N(m)-N(f) 1010-127-R Attenuator, 30 dB, 150W, DC to 3 GHz, N(m)-N(f) 3-1010-124 Attenuator, 40 dB, 100W, DC to 8.5 GHz, N(m)-N(f), Uni-directional 1010-121 Attenuator, 40 dB, 100W, DC to 18 GHz, N(m)-N(f) 1010-128-R Attenuator, 40 dB, 150W, DC to 3 GHz, N(m)-N(f) Miscellaneous Accessories 633-27 Rechargeable Battery, Ni-MH 806-141 Automotive Cigarette Lighter/12 Volt DC Adapter 40-168-R AC/DC Adapter 2000-1029 Battery Charger, NiMH, w/ Universal Power Supply 551-1691-R USB to RS-232 Adapter Cable

800-441 Serial Interface Cable 65717 Soft Carrying Case 67135 Site Master Backpack 760-243-R Transit Case ODTF-1 Optical DTF Module 2300-347 Handheld Software Tools CDROM

1-5
Chapter 1 General Information
Power Monitor Detectors 5400-71N50 Detector, .001 to 3 GHz, N(m), 50W 5400-71N75 Detector, .001 to 3 GHz, N(m), 75W 560-7N50B Detector, 10 MHz to 20 GHz, N(m), 50 W 560-7S50B Detector, 10 MHz to 20 GHz, WSMA(m), 50 W 560-7K50 Detector, 10 MHz to 40 GHz, K(m), 50 W 560-7VA50 Detector, 10 MHz to 50 GHz, V(m), 50 W Power Monitor Extender Cables 800-109 7.6 m (25 ft) 800-111 30.5 m (100 ft) High Accy Power Meter Acc PSN50 High Accuracy Power Sensor, 50 MHz to 6 GHz MA24104A Inline High Power Sensor, 600 MHz to 4 GHz 40-168-R AC-DC Adapter 800-441 Serial Interface Cable 3-1010-122 Attenuator, 20 dB, 5 Watt, DC to 12.4 GHz, N(m)-N(f) 1010-127-R Attenuator, 30 dB, 150W, DC to 3 GHz, N(m)-N(f) 3-1010-123 Attenuator, 30 dB, 50 Watt, DC to 8.5 GHz, N(m)-N(f) 3-1010-124 Attenuator, 40 dB, 100W, DC to 8.5 GHz, N(m)-N(f), Uni-directional 1010-128-R Attenuator, 40 dB, 150W, DC to 3 GHz, N(m)-N(f) Documentation 10580-00100 S33xD Programming Manual (available on disk or at www.us.anritsu.com) 10580-00101 S331D Maintenance Manual

1-6
Chapter 1 General Information

Performance Specifications
Performance specifications are provided in Table 1-1. All specifications apply when calibrated at ambient temperature after a five minute warm up. Typical values are given for reference, and are not guaranteed.

1-7
Chapter 1 General Information Cable and Antenna Analyzer
Frequency Range: 25 MHz to 4000 MHz Frequency Accuracy: _ _ 50 ppm @ +25C Frequency Resolution: 1 kHz (CW On) 100 kHz (CW Off) Output Power: 0 dBm (typical) Immunity to Interfering Signals: on-channel +17 dBm on-frequency 5 dBm Measurement speed: _ 2.5 msec / data point (CW ON) Number of data points: 130 or 259 or 517 Return Loss: Range: 0.00 to 60.00 dB Resolution: 0.01 dB VSWR: Range: 1.00 to 65.00 Resolution: 0.01 Cable Loss:

Range: 0.00 to 30.00 dB Resolution: 0.01 dB Measurement Accuracy: > 42 dB corrected directivity after calibration Distance-To-Fault Vertical Range: Return Loss: 0.00 to 60.00 dB VSWR: 1.00 to 65.00 Horizontal Range: 0 to (# of data pts 1) x Resolution to a maximum of 1497m (4911 ft) # of data pts = 130 or 259 or 517 Horizontal Resolution (rectangular windowing): Resolution (meters) = (1.5 x 108) x (Vp)/DF Where Vp is the relative propagation velocity of the cable and DF is the stop frequency minus the start frequency (in Hz). Table 1-1. Performance Specifications (1 of 3)

1-8
Chapter 1 General Information Power Monitor (Option 5, with external detector)
Measurement Range: 50 dBm to +16 dBm (10 nW to 40 mW) Offset Range: 0 dB to +60 dB Display Range: 80 dBm to 80 dBm Resolution: 0.1 dB, 0.1 xW Measurement Accuracy: 1 dB maximum for >40 dBm and <18 GHz using 560-7N50B (see uncertainty curves)

High Accuracy Power Meter (Option 19) Compatible Sensors: PSN50 and MA24104A
PSN50 High Accuracy Power Sensor: Frequency Range: 50 MHz to 6 GHz Measurement Range: 30 dBm to +20 dBm Sensor Linearity: 0.13 dB Input Connector: Type N, male, 50_
Refer to the PSN50 Technical Data Sheet, PN: 11410-00423, for complete specifications.

MA24104A Inline High Power Sensor: Frequency Range: 600 MHz to 4 GHz Measurement Range: +3 dBm to +51.76 dBm (2 mW to 150 W) Sensor Linearity: 0.13 dB Input Connector: Type N, female, 50_ Output Connector: Type N, female, 50_
Refer to the MA24104A Technical Data Sheet, PN: 11410-00483, for complete specifications.

Table 1-1. Performance Specifications (2 of 3)

1-9
Chapter 1 General Information General
Language Support: English, Spanish, French, German, Chinese, Japanese Internal Trace Memory: Up to 300 traces Setup Configurations: 10 Display: Standard color TFT (640x480) display with variable brightness control Inputs and Outputs Ports: RF Out: Type N, female, 50_ Maximum Input without Damage: +23 dBm, 50 VDC Serial Interface: RS-232 9 pin D-sub, three wire serial Electromagnetic Compatibility: Meets European Community requirements for CE marking Safety: Conforms to EN 61010-1 for Class 1 portable equipment Temperature: Operating: -10C to 55C, humidity 85% or less Non-operating: 51C to +71C (store battery separately between 0C and +40C for any prolonged non-operating storage period) Power Supply: External DC Input: +12 to +15 volt dc, 3A maximum

Internal: NiMH battery: 10.8 volts, 1800 mAh Dimensions: Size (w x h x d): 25.4 cm x 17.8 cm x 6.1 cm (10.0 in x 7.0 in x 2.4 in) Table 1-1. Performance Specifications (3 of 3)

Preventive Maintenance
Site Master preventive maintenance consists of cleaning the unit and inspecting and cleaning the RF connectors on the instrument and all accessories. Clean the Site Master with a soft, lint-free cloth dampened with water or water and a mild cleaning solution. CAUTION: To avoid damaging the display or case, do not use solvents or abrasive cleaners. Clean the RF connectors and center pins with a cotton swab dampened with denatured alcohol. Visually inspect the connectors. The fingers of the N (f) connectors and the pins of the N (m) connectors should be unbroken and uniform in appearance. If you are unsure whether the connectors are good, gauge the connectors to confirm that the dimensions are correct. Visually inspect the test port cable(s). The test port cable should be uniform in appearance, not stretched, kinked, dented, or broken.

Calibration
The Site Master is a field portable unit operating in the rigors of the test environment. An Open-Short-Load (OSL) calibration, InstaCal calibration, FlexCal calibration with open-short-load, or FlexCal calibration with an InstaCal module should be performed prior to making a measurement in the field (see Calibration, page 3-2). A built-in temperature sensor in the Site Master advises the user when the internal temperature has exceeded a measurement accuracy window, and the user is advised to perform another calibration in order to maintain the integrity of the measurement. NOTES: For best calibration resultscompensation for all measurement uncertainties ensure that the Open/Short/Load is at the end of the test port or optional extension cable; that is, at the same point that you will connect the antenna or device to be tested. For best results, use a phase stable Test Port Extension Cable (see Optional Accessories). If you use a typical laboratory cable to extend the Site Master test port to the device under test, cable bending subsequent to the OSL calibration will cause uncompensated phase reflections inside the cable. Thus, cables which are NOT phase stable may cause measurement errors that are more pronounced as the test frequency increases. For optimum calibration, Anritsu recommends using precision calibration components.

1-10
Chapter 1 General Information

InstaCal Module
The Anritsu InstaCal module can be used in place of discrete components to calibrate the Site Master. The InstaCal module can be used to perform an Open, Short and Load (OSL) or a FlexCal calibration procedure. Calibration of the Site Master with the InstaCal takes approximately 45 seconds (see Calibration, page 3-2). Unlike a discrete calibration component, the InstaCal module can not be used at the top of the tower to conduct load or insertion loss measurements. Anritsu recommends annual verification of the InstaCal module to verify performance with precision instrument data. The verification may be performed at a local Anritsu Service Center or at the Anritsu factory.

Annual Verification
Anritsu recommends an annual calibration and performance verification of the Site Master and the OSL calibration components and InstaCal module by local Anritsu service centers.

Anritsu service centers are listed in Table 1-2 on the following page. The Site Master itself is self-calibrating, meaning that there are no field-adjustable components. However, the OSL calibration components are crucial to the integrity of the calibration and therefore, must be verified periodically to ensure performance conformity. This is especially important if the OSL calibration components have been accidentally dropped or over-torqued.

ESD Precautions
The Site Master, like other high performance instruments, is susceptible to ESD damage. Very often, coaxial cables and antennas build up a static charge, which, if allowed to discharge by connecting to the Site Master, may damage the Site Master input circuitry. Site Master operators should be aware of the potential for ESD damage and take all necessary precautions. Operators should exercise practices outlined within industry standards like JEDEC-625 (EIA-625), MIL-HDBK-263, and MIL-STD-1686, which pertain to ESD and ESDS devices, equipment, and practices. As these apply to the Site Master, it is recommended to dissipate any static charges that may be present before connecting the coaxial cables or antennas to the Site Master. This may be as simple as temporarily attaching a short or load device to the cable or antenna prior to attaching to the Site Master. It is important to remember that the operator may also carry a static charge that can cause damage. Following the practices outlined in the above standards will insure a safe environment for both personnel and equipment.

Anritsu Service Centers


To locate the Anritsu Service Center nearest you, please visit: www.anritsu.com/contact.asp

Mode References
The term VNA in reference to the Site Master denotes cable and antenna analyzer modes.

1-11
Chapter 1 General Information

Chapter 2 Functions and Operations


Introduction
This chapter provides a brief overview of the Site Master functions and operations, providing the user with a starting point for making basic measurements. For more detailed information, refer to the specific chapters for the measurements being made. The Site Master is designed specifically for field environments and applications requiring mobility. As such, it is a lightweight, handheld, battery operated unit which can be easily carried to any location, and is capable of up to 1.5 hours of continuous operation from a field replaceable battery for extended time in the field. Built-in energy conservation features allow battery life to be further extended. The Site Master can also be powered by an external DC source. The external source can be either the Anritsu AC-DC Adapter (P/N 40-168-R) or the Automotive Cigarette Lighter Adapter (P/N 806-141). Both items are standard accessories.

Test Connector Panel


The connectors and indicators located on the test panel (Figure 2-1) are listed and described below. 12-15VDC (3A) 12 to 15 Vdc @ 3A input to power the unit or for battery charging. WARNING

When using the AC-DC Adapter, always use a three-wire power cable connected to a three-wire power line outlet. If power is supplied without grounding the equipment in this manner, there is a risk of receiving a severe or fatal electric shock, or damaging the equipment.

2-1
Figure 2-1. Test Connector Panel

Battery Charging Illuminates when the battery is being charged. The indicator automatically shuts off when the battery is fully charged. External Power Illuminates when the Site Master is being powered by the external charging unit. Serial Interface RS232 DB9 interface to a COM port on a personal computer (for use with the Anritsu Handheld Software Tools program) or to a supported printer. RF Out/ Reflection 50_ RF output, 50 _ impedance, for reflection measurements. Maximum input is +23 dBm at _50 Vdc. RF Detector (Option 5) RF detector connector for Power Monitor measurements using an external detector. Refer to the table of available RF Detectors on page 1-3.

2-2
Chapter 2 Functions and Operations

Display Overview
Figure 2-2 illustrates some of the key information areas of the S331D display. Chapter 2 Functions and Operations

2-3
TITLE BAR DATA POINTS SWEEP TIME CALIBRATION STATUS MESSAGEAREA CURRENT MENU

Figure 2-2. S331D Display Overview

Front Panel Overview


The Site Master menu-driven user interface is easy to use and requires little training. Hard keys on the front panel are used to initiate function-specific menus. There are four function hard keys located below the status window: Mode, Frequency/Distance, Amplitude and Measure/Display. There are seventeen keypad hard keys located to the right of the status window. Twelve of the keypad hard keys perform more than one function, depending on the current mode of operation. The dual purpose keys are labeled with one function in black, the other in blue. There are also six soft keys that change function depending upon the current mode selection. The current soft key function is indicated in the soft key menu area to the right of the status window. The locations of the different keys are illustrated in Figure 2-3. The following sections describe the various key functions.

2-4

Chapter 2 Functions and Operations


Soft Keys Soft Key Menu Keypad Hard Keys Function Hard Keys
HOLD RUN START CAL AUTO SCALE SAVE SETUP RECALL SETUP LIMIT MARKER SAVE DISPLAY RECALL DISPLAY PRINT

MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS


ENTER CLEAR ESCAPE ON OFF

/ 12 4

56
78

90
3
+-

S332D

Figure 2-3. Site Master Front Panel

Function Hard Keys


MODE Opens the mode selection box (below). Use the Up/Down arrow key to select a mode. Press the ENTER key to implement. NOTE: Available mode selections will vary according to model number and options installed. FREQ/DIST Displays the Frequency or Distance to Fault soft key menus depending on the measurement mode (see page 2-11). AMPLITUDE Displays the amplitude soft key menu for the current operating mode (see page 2-13). MEAS/DISP Displays the measurement and display soft key menus for the current operating mode (see page 2-14). Chapter 2 Functions and Operations

2-5
_ Measurement Mode Freq - SWR Return Loss Cable Loss - One Port DTF - SWR Return Loss Power Monitor (External Detector) High Accuracy Power Meter Figure 2-4. Mode Selection Box

Keypad Hard Keys


This section contains an alphabetical listing of the Site Master front panel keypad controls along with a brief description of each. More detailed descriptions of the major function keys follow. The following keypad hard key functions are printed in black on the keypad keys. 0-9 These keys are used to enter numerical data as required to setup or perform measurements. +/ The plus/minus key is used to enter positive or negative values as required to setup or perform measurements. _ The decimal point is used to enter decimal values as required to setup or perform measurements. ESCAPE CLEAR Exits the present operation or clears the status window. If a parameter is being edited, pressing this key will clear the value currently being entered

and restore the last valid entry. Pressing this key again will close the parameter. During normal sweeping, pressing this key will move up one menu level. Up/Down Arrows Increments or decrements a parameter value. The specific parameter value affected typically appears in the message area of the LCD. ENTER Implements the current action or parameter selection. ON OFF Turns the Anritsu Site Master on or off. When turned on, the saved system state at the last turn-off is restored. If the ESCAPE/CLEAR key is held down while the ON/OFF key is pressed, the factory preset state will be restored. SYS Allows selection of system and application setup parameters and the display language.

2-6
Chapter 2 Functions and Operations The following keypad hard key functions are printed in blue on the keypad keys. This key is used to adust the display brightness. Use the Up/Down arrow key and ENTER to adjust the brightness. AUTO SCALE Automatically scales the status window for optimum resolution in cable and antenna analyzer mode. LIMIT Displays the limit line menu for the current operating mode when in cable, antenna analyzer. MARKER Displays the marker menu of the current operating mode when in cable, antenna analyzer mode. PRINT Prints the current display to the selected printer via the RS232 serial port. RECALL DISPLAY Recalls a previously saved trace from memory. When the key is pressed, a Recall Trace selection box appears on the display. Select a trace using the Up/Down arrow key and press the ENTER key to implement. RECALL SETUP Recalls a previously saved setup from a memory location. When the key is pressed, a Recall Setup selection box appears on the display. Select a setup using the Up/Down arrow key and press the ENTER key to implement. Setup 0 recalls the factory preset state for the current mode. RUN HOLD When in the Hold mode, this key starts the Site Master sweeping and provides a Single Sweep Mode trigger; when in the Run mode, it pauses the sweep. When in the Hold mode, the hold symbol (page 2-17) appears on the display. Hold mode can be used to conserve battery power. SAVE DISPLAY Saves up to 300 displayed traces to non-volatile memory. When the key is pressed, the Trace Name: box appears. Use the soft keys to enter up to 16 alphanumeric characters for that trace name and press the ENTER key to save the trace. SAVE SETUP

Saves the current system setup to an internal non-volatile memory location. The number of locations available varies with the model number and installed options. There are ten available locations in cable and antenna analyzer mode. When the key is pressed, a Save Setup selection box appears on the status window. Use the Up/Down arrow key to select a setup and press the ENTER key to implement. START CAL Starts the calibration in SWR, Return Loss, Cable Loss, or DTF measurement modes. Chapter 2 Functions and Operations

2-7

Soft Keys
Each keypad key opens a set of soft key selections. Each of the soft keys has a corresponding soft key label area on the status window. The label identifies the function of the soft key for the current Mode selection. The following figures show the soft key labels for each Mode selection.

2-8
Chapter 2 Functions and Operations MODE=Return Loss: SOFTKEYS: F1
130 F2 259 517 Bottom Signal Standard
Downlink Up+Down link Uplink Page Up Select/ Deselect Show Selected

Select Trace
Page Down

Back Back
Bottom of List

Delete Trace
Delete All Traces

Top
Select Standard Top of List

On/Off Resolution Single Sweep Trace Math Trace Overlay Fixed CW

FREQ/DIST AMPLITUDE MEAS/DISP


Page Up Page Down Bottom of List Top of List

Figure 2-5. Return Loss Mode Soft Key Labels

Chapter 2 Functions and Operations

2-9
MODE=DTF: SOFTKEYS:
Bottom Top

FREQ/DIST AMPLITUDE
D2 DTF Aid More D1 Loss Cable
Window

Back Prop Vel Page Up Select Trace Page Down Back


Bottom of List

Delete Trace
Delete All Traces Top of List

On/Off Resolution Single Sweep Trace Math Trace Overlay Fixed CW

MEAS/DISP
Figure 2-6. Distance to Fault Mode Soft Key Labels

2-10
Chapter 2 Functions and Operations
System Options Hour
Application Options

Clock Status Minute Self Test Month Language


English

Day Year

Units GPS On/Off Printer CAL Mode


Change Date Format

Back Back Back Location Quality Reset Back GPS

Figure 2-8. SYS Key Menu in Cable and Antenna Analyzer Mode
SOFTKEYS: Center
Signal Standard

Offset dB Zero Rel

FREQ/DIST AMPLITUDE
Max Hold Limit ON/OFF Lower Limit Upper Limit Limit Units Running Averages

MEAS/DISP
Downlink Uplink Page Up Select/ Deselect Show Selected Page Down

Back
Bottom of List Select Standard Top of List Select Channel

Figure 2-7. High Accuracy Power Sensor Mode (Option 19) Soft Keys

FREQ/DIST Displays the frequency and distance menu depending on the measurement mode. Frequency Menu The frequency and distance menu for cable and antenna analyzer measurements provides for setting sweep frequency end points when Freq mode is selected. Selected frequency values may be changed using the keypad or Up/Down arrow key. F1 Opens the F1 parameter for data entry. This is the start value for the frequency sweep. Press ENTER when data entry is complete. F2 Opens the F2 parameter for data entry. This is the stop value for the frequency sweep. Press ENTER when data entry is complete. Signal Standard Allows selection of the signal standard to be used. Select from the available international standards (Appendix C). Distance Menu Provides for setting Distance to Fault parameters when a DTF mode is selected. Choosing DIST causes the soft keys, below, to be displayed and the corresponding values to be shown in the message area. Selected distance values may be changed using the keypad or Up/Down arrow key. D1 Opens the start distance (D1) parameter for data entry. This is the start value for the distance range (D1 default = 0). Press ENTER when data entry is complete. D2 Opens the end distance (D2) parameter for data entry. This is the end value for the distance range. Press ENTER when data entry is complete.

Provides interactive help to optimize DTF set up parameters. Use the Up/Down arrow key to select a parameter to edit. Press ENTER when data entry is complete. More Selects the Distance Sub-Menu, detailed below. Loss Opens the Cable Loss parameter for data entry. Enter the loss per meter (or foot) for the type of transmission line being tested. Press ENTER when data entry is complete. (Range is 0.5 to 5.0 dB/m, 1.524 dB/ft) Prop Vel (relative propagation velocity) Opens the Propagation Velocity parameter for data entry. Enter the propagation velocity for the type of transmission line being tested. Press ENTER when data entry is complete. (Range is 0.010 to 1.000) Cable Opens a list of cable three common coaxial folders (1000 MHz, 2000 MHz, and 2500 MHz) and one custom folder. Select either folder and use the Up/Down arrow key and ENTER to make a selection. This feature provides a rapid means of setting both cable loss and propagation velocity. (Refer to Appendix A for a listing of common coaxial cables showing values for Relative Propagation Velocity and Nominal Attenuation in dB/m or dB/ft @ 1000 MHz, 2000 MHz and 2500 MHz.) The custom cable folder can consist of up to 49 user-defined cable parameters uploaded via the Handheld Software Tools program. Window Opens a menu of FFT windowing types for the DTF calculation. Scroll the menu using the Up/Down arrow key and make a selection with the ENTER key. Refer to Appendix B for details on windowing. Back Returns to the Distance Menu. Chapter 2 Functions and Operations
DTF Aid

2-11
MARKER Choosing MARKER in cable and antenna analyzer freq and dist mode causes the soft keys, below, to be displayed and the corresponding values to be shown in the message area. Selected frequency marker or distance marker locations may be changed using the keypad or Up/Down arrow key. M1 Selects the M1 marker parameter and opens the M1 marker second level menu. On/Off Turns the selected marker on or off. Edit Opens the selected marker parameter for data entry. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Marker To Peak Places the selected marker at the frequency or distance with the maximum amplitude value. Marker To Valley Places the selected marker at the frequency or distance with the minimum amplitude value. Back Returns to the Main Markers Menu. M2 through M4 Selects the marker parameter and opens the marker second level menu. On/Off Turns the selected marker on or off. Edit Opens the selected marker parameter for data entry. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Delta (Mx-M1) Displays delta amplitude value as well as delta frequency or distance for the selected marker with respect to the M1 marker. Marker To Peak Places the selected marker at the frequency or distance with the maximum amplitude value. Marker To Valley Places the selected marker at the frequency or distance with the minimum amplitude value. Back Returns to the Main Markers Menu.

All Off Turns all markers off. More Opens the continuation of the Marker Menus. M5 Selects the M5 marker parameter and opens the M5

second level

menu.
On/Off Turns the selected marker on or off. Edit Opens the selected marker parameter for

data entry. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Peak Between M1 & M2 Places the selected marker at the frequency or distance with the maximum amplitude value between marker M1 and marker M2. Valley Between M1 & M2 Places the selected marker at the frequency or distance with the minimum amplitude value between marker M1 and marker M2. Back Returns to the Main Markers Menu.

2-12
Chapter 2 Functions and Operations M6 Selects the M6 marker parameter and opens the M6 second level menu. On/Off Turns the selected marker on or off. Edit Opens the selected marker parameter for data entry. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Peak Between M3 & M4 Places the selected marker at the peak between marker M3 and marker M4. Valley Between M3 & M4 Places the selected marker at the valley between marker M3 and marker M4. Back Returns to the Main Markers Menu. All Off Turns all markers off Back Returns to the Main Markers Menu. LIMIT Pressing LIMIT in cable and antenna analyzer frequency and distance mode activates a menu of limit related functions. Use the corresponding soft key to select the desired limit function. Then use the Up/Down arrow key to change its value, which is displayed in the message area at the bottom of the status window. Choosing LIMIT in Freq or DTF measurement modes causes the soft keys below to be displayed. Single Limit Sets a single limit value in dBm. Menu choices are: On/Off Turns the single limit function on or off Edit Allows entry of the limit amplitude. Back Returns to the previous menu. Multiple Limits Sets multiple user defined limits, and can be used to create a limit mask for quick pass/fail measurements. Segment 1 through Segment 5 Opens the segment menu. On/Off Turns the segment on or off. Edit Opens the parameter for data entry. Prev Segment Edit or view the parameters of the previous segment. Next Segment Edit or view the parameters of the next segment. If the next segment is off when this button is pressed, the starting point of the next segment will be set equal to the ending point of the current segment. Back Returns to the previous menu. Back Returns to the previous menu. Limit Beep Turns the audible limit beep indicator on or off. Chapter 2 Functions and Operations

2-13

SYS In cable and antenna analyzer or optional power meter mode, pressing the SYS key displays the following System menu soft key selections: System Options Displays a second level of system option functions: Clock Displays a second level of functions: Hour Enter the hour (0-23) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Minute Enter the minute (0-59) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Month Enter the month (1-12) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Day Enter the day using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Year Enter the year (2003-2036) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Back Returns to the top-level SYS menu. Printer Displays a menu of supported printers. Use the Up/Down arrow key and ENTER key to make the selection. Units Select the unit of measurement (metric or English). Change Date Format Toggles the date format between MM/DD/YYYY, DD/MM/YYYY, and YYYY/MM/DD. Back Returns to the top-level SYS menu. Application Options Application options displays options applicable to particular mode. CAL Mode In cable and antenna analyzer modes, selects either OSL Cal or FlexCal_. FlexCal is a broadband frequency calibration valid from 25 MHz to 4 GHz (2 MHz to 6 GHz with Options 2 and 16). Refer to Calibration, page 3-2, for more information. Back Returns to the top-level SYS menu. Self Test Start an instrument self test. Status In cable and antenna analyzer freq or dist measurement mode, displays the current instrument status, including calibration status, temperature, and battery charge state. Press ESCAPE to return to operation. Language Pressing this soft key immediately changes the language used to display messages on the Site Master status window. Choices are English, French, German, Spanish, Chinese, and Japanese. The default language is English. In Power Monitor mode, pressing the SYS key displays the following System menu soft key selections: System Options Displays a second level of system option functions: Clock Displays a second level of functions: Hour Enter the hour (0-23) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value.

2-14
Chapter 2 Functions and Operations Minute Enter the minute (0-59) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Month Enter the month (1-12) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to

restore the previous value. Day Enter the day using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Year Enter the year (2003-2036) using the Up/Down arrow key or the keypad. Press ENTER when data entry is complete or ESCAPE to restore the previous value. Back Returns to the top-level SYS menu. Printer Displays a menu of supported printers. Use the Up/Down arrow key and ENTER key to make the selection. Units Select the unit of measurement (metric or English). Change Date Format Toggles the date format between MM/DD/YYYY, DD/MM/YYYY, and YYYY/MM/DD. Back Returns to the top-level SYS menu. Self Test Start an instrument self test. Status In cable and antenna analyzer freq or dist measurement mode, displays the current instrument status, including calibration status, temperature, and battery charge state. Press ESCAPE to return to operation. Language Pressing this soft key immediately changes the language used to display messages on the Site Master status window. Choices are English, French, German, Spanish, Chinese, and Japanese. The default language is English. Chapter 2 Functions and Operations

2-15

Power Monitor, External Detector (Option 5)


Selecting Power Monitor (External Detector) from the mode menu causes the soft keys, described below, to be displayed and the corresponding values shown in the message area. Units Toggles between dBm and Watts. Rel Turns relative mode OFF, if currently ON. If relative mode is currently OFF, turns it ON and causes the power level to be measured and saved as the base level. Subsequent measurements are then displayed relative to this saved value. With units of dBm, relative mode displays dBr; with units of Watts, relative mode displays % (percent). Offset dB Turns Offset OFF, if currently ON. If Offset is currently OFF, turns it ON and opens the Offset parameter for data entry (0-60). Press ENTER when data entry is complete. Offset is the attenuation (in dB) inserted in the line between the DUT and the RF detector. The attenuation is added to the measured input level prior to display. Zero Turns Zero OFF, if currently ON. If Zero is currently OFF, this soft key turns it ON and initiates collection of a series of power level samples, which are averaged and saved. This saved value is then subtracted from subsequent measurements prior to display.

2-16
Chapter 2 Functions and Operations

Symbols
Table 2-1 provides a listing of the symbols used as condition indicators on the LCD status window. Chapter 2 Functions and Operations

2-17
Icon Symbol Site Master is in Hold for power conservation. To resume sweeping, press the RUN/HOLD key. When running on battery power, after 10 minutes without a key press, the Site Master will automatically activate the power

conservation mode. Integrator Failure. Intermittent integrator failure may be caused by interference from another antenna. Persistent integrator failure indicates a need to return the Site Master to the nearest Anritsu service center for repair. Lock fail indication. Check battery. (If the Site Master fails to lock with a fully charged battery, call your Anritsu Service Center.) When calibration is performed, the Site Master stores the temperature. If the temperature drifts outside the specified range, this icon will appear at the top of the status window, and the Cal Off message will be displayed. A recalibration at the current temperature is recommended. Indicates the remaining charge on the battery. The inner white rectangle grows longer as the battery charge depletes. Indicates internal data processing. The Site Master has been calibrated with discrete Open, Short and Load components. The Site Master has been calibrated with the InstaCal Module. The Site Master has not been calibrated. The Site Master has been calibrated with discrete Open, Short and Load components for the frequency supported by the unit. The Site Master has been calibrated with the InstaCal Module for the frequency supported by the unit. Table 2-1. LCD Icon Symbols
HOLD

dx T

Cal On Cal On! Cal Off FlexCal On FlexCal On!

Self Test
At turn-on, the Site Master runs through a series of quick checks to ensure the system is functioning properly. Note that the voltage and temperature are displayed in the lower left corner below the self test message. If the battery is low, or if the ambient temperature is not within the specified operational range, Self Test will fail. If Self Test fails and the battery is fully charged and the Site Master is within the specified operating temperature range, call your Anritsu Service Center found from: http://www.anritsu.com/Contact.asp

2-18
Chapter 2 Functions and Operations

Error Messages
Self Test Error Messages
A listing of Self Test Error messages is provided in Table 2-2. Chapter 2 Functions and Operations

2-19
Error Message Description

Battery Low Battery voltage is less than 9.5 volts. Charge battery. If condition persists, call your Anritsu Service Center. External Power Low External supply voltage is less than 10 volts. Call your Anritsu Service Center PLL Failed Phase-locked loops failed to lock. Charge battery. If condition persists

with a fully charged battery, call your Anritsu Service Center Integrator Failed Integration circuit could not charge to a valid level. Charge battery. If condition persists with a fully charged battery, call your Anritsu Service Center. EEPROM R/W Failed Non-volatile memory system has failed. Call your Anritsu Service Center. Out Of Temp. Range Ambient temperature is not within the specified operating range. If the temperature is within the specified operating range and the condition persists, call your Anritsu Service Center. RTC Battery Low The internal real-time clock battery is low. A low or drained clock battery will affect the date stamp on saved traces. Contact your nearest Anritsu Service Center. Battery Cal Lost Battery communication failed. The indicated battery charge status may be invalid. If condition persists, call your Anritsu Service Center. Memory Fail The EEPROM test on the Site Master main board has failed. If condition persists, call your Anritsu Service Center. The time and date Have not been set on this Site Master. To set it, after exiting here press the <SYS> [Clock] keys. Press ENTER or ESC to continue The time and date are not properly set in the Site Master. If condition persists, call your Anritsu Service Center.
Note: Page 1-11 provides contact information for Anritsu Service Centers.

Table 2-2. Self Test Error Messages

Range Error Messages


A listing of Range Error messages is provided in Table 2-3.

2-20
Chapter 2 Functions and Operations
Error Message Description

RANGE ERROR:F1 > F2 The start (F1) frequency is greater than the stop (F2) frequency. RANGE ERROR:D1 > D2 The start (D1) distance is greater than the stop (D2) distance. RANGE ERROR:D2 > DMax=xx.x ft (m) The stop distance (D2) exceeds the maximum unaliased range. This range is determined by the frequency span, number of points, and relative propagation velocity: MaximumUnaliased Range dp V f FF

(1.5 108) ( 1) ( ) 21 Where: dp is the number of data points (130, 259, or 517) Vf is the relative propagation velocity F2 is the stop frequency in Hz F1 is the start frequency in Hz Maximum Unaliased Range is in meters RANGE ERROR: TOP<=BOTTOM The SWR scale parameter top value is less than or equal to its bottom value. RANGE ERROR: TOP>=BOTTOM The RL scale parameter top value is greater than or equal to its bottom value. Table 2-3. Range Error Messages

InstaCal Error Messages


If the serial number of the connected InstaCal module does not match the serial number stored in the Site Master, the following message is displayed: The InstaCal characterization data stored in the Site Master is for a module different than the one currently connected. Site Master contains data for InstaCal module S/N: xxxxx Currently connected InstaCal Module S/N: xxxxx Would you like to overwrite the previously loaded InstaCal characterization? Press the YES soft key to update the stored InstaCal characterization to use the currently connected module. Press the NO soft key to keep the stored InstaCal characterization. A listing of possible InstaCal error messages is provided in Table 2-4. Chapter 2 Functions and Operations

2-21
Error Message Description

Failed to read serial number of InstaCal module


The Site Master was unable to read the InstaCal module serial number.

Failed to successfully transfer instacal module data to Site Master


The Site Master was unable to transfer all necessary data between the InstaCal module and the Site Master.

Failed to set baud with InstaCal module


The Site Master was unable to establish communication with the InstaCal module. Table 2-4. InstaCal Error Messages

High Accuracy Power Meter (Option 19) Error Messages


The following error messages could be displayed on the Site Master when using the High Accuracy Power Meter mode with Power Sensor PSN50. If any error condition persists, contact your local Anritsu Service Center.

General Error Messages


A listing of General Error Messages is provided below.

2-22

Chapter 2 Functions and Operations


Error Message Description

Warning! Power Supply Error


Verify that the supply is connected properly.

Warning! RF Power Level is too high


The specified upper measurement range is +20 dBm. Do not exceed the specification.

Warning! Sensor not zeroed properly. Zero sensor again


The sensor must be zeroed with nothing connected to it. Warning! Specified temperature range (0 to 50_C) exceeded The PSN50 sensor temperature range is 0 to 50_C. Warning! Temperature has changed. Zero sensor again The temperature changed more than the allowable limit after the sensor was zeroed. Table 2-5. Option 19 Error Messages Error Message Description

CAL Incomplete A complete open, short, and load calibration must be performed before calibration can be turned on. Dist Requires F1 < F2 Valid distance to fault plots require a non-zero frequency span. Invalid Sweep Data The sweep data is invalid. Use Options menu to select a printer Attempting to print a display with no printer selected. Select a printer, then retry. Flexcal is not suitable for this case, Change To OSL CAL mode (SYS-Options) The cable is too long or too reflective for FlexCal to work. OSL cal must be used instead. Cannot zero input signal too high Attempting to perform a Power Meter zero adjust function with an input of greater than 20 dBm.
Table 2-6. General Error Messages

Battery Information
Charging a New Battery
The NiMH battery supplied with the Site Master has already completed three charge and discharge cycles at the factory and full battery performance should be realized after your first charge. NOTE: Use only Anritsu approved batteries, adapters and chargers with this instrument. The battery will not charge if the battery temperature is above 45_ C or below 0_ C.

Charging the Battery in the Site Master


The battery can be charged while installed in the Site Master. Step 1. Turn the Site Master off. Step 2. Connect the AC-DC adapter (Anritsu part number: 40-168-R) to the Site Master charging port. Step 3. Connect the AC adapter to a 120 VAC or 240 VAC power source as appropriate for your application. The green external power indicator on the Site Master will illuminate, indicating the presence of external DC power, the battery charge indicator will light, and the battery will begin fast charging. If the battery fails to charge, contact your nearest Anritsu service center. NOTES: If the battery temperature exceeds 50_ C while charging, the charging will stop and the charge indicator will turn off. Charging will resume automatically when the temperature drops below 50_ C.

Charging the Battery in the Optional Charger


Up to two batteries can be charged sequentially in the optional battery charger. Step 1. Remove the NiMH battery from your Site Master and place it in the optional charger (Anritsu part number 2000-1029). Step 2. Connect the lead from the AC-DC adapter to the charger. Step 3. Connect the AC-DC adapter to a 120 VAC or 240 VAC power source as appropriate for your application. Each battery holder in the optional charger has an LED charging status indicator. The LED color changes as the battery is charged: Red indicates the battery is charging Green indicates the battery is fully charged Yellow indicates the battery is in a waiting state (see below). A yellow light may occur because the battery became too warm during the charge cycle. The charger will allow the battery to cool off before continuing the charge. A yellow light may also indicate that the charger is alternating charge to each of the two batteries. Chapter 2 Functions and Operations

2-23
A blinking red light indicates less than 13 VDC is being supplied to the charger stand. Check that the correct AC charger adapter is connected to the charger stand. If the battery fails to charge, contact your nearest Anritsu Service Center.

Determining Remaining Battery Life


When the AC-DC adapter is unplugged from the Site Master, the battery indicator symbol will be continuously displayed at the top left corner of the Site Master display (Figure 2-7). A totally black bar within the battery icon indicates a fully charged battery. When LOW BATT replaces the battery indicator bar at the top left corner, a couple of minutes of measurement time remains. If a flashing LOW BATT is accompanied by an audio beep at the end of each trace, the battery has approximately one minute of useable time remaining. Once all the power has drained from the battery, the Site Master LCD will fade. At this point, your Site Master will switch itself off and the battery will need to be recharged. During operation, the battery condition can be viewed by pressing the SYS key and selecting the Self Test soft key (Figure 2-8). The battery condition will be displayed as a percentage of charge remaining.

2-24
Chapter 2 Functions and Operations

BATTERY INDICATOR
All Off More

Figure 2-7. Site Master Battery Indicator Selftest Temperature . . . . . . . . . . . . 24_C Memory . . . . . . . . . . . . . . . . PASSED

RTC Battery. . . . . . . . . . . . . 3.1V Voltage . . . . . . . . . . . . . . . . Battery (11.1V) Battery Cal . . .. . . . . . . . . . . PASSED Battery Charge. . . . . . . . . . . 84% (I = 743mA) VNA PLL . . . . . . . . . . . . . . . PASSED VNA Integrator . . . . . . . . . . PASSED Press ESCAPE to return. Figure 2-8. Self Test Display

Battery Life
The NiMH battery will last longer and perform better if allowed to completely discharge before recharging. For maximum battery life, it is recommended that the NiMH battery be completely discharged and recharged once every three months. The charging circuitry inside the Site Master is designed to optimize the life of the battery. If the temperature inside the instrument exceeds 50_C, the current charge cycle will be suspended and a new charge cycle will not start until the temperature has come down to 50 _C. The Site Master is also equipped with an automatic charging process that changes the charging level based on the battery capacity. If the battery has been completely discharged to zero volts, a pre-charge at a low DC current will be applied until the battery reaches a level which is safe for a faster charge cycle. Similarly, the charging level will change when the battery is close to fully charged. This charging process helps maximize the number of recharge cycles available from the battery. It is normal for NiMH batteries to self-discharge during storage (Figure 2-9) and to degrade to 80% of original capacity after 12 months of continuous use. The battery can be charged and discharged 300 to 500 times, but it will eventually wear out. The battery may need to be replaced when the operating time between charging is noticeably shorter than normal. Chapter 2 Functions and Operations

2-25
Figure 2-9. NiMH Battery Storage Characteristics

Important Battery Information


_ The

NiMH battery supplied with the Site Master has already completed three charge and discharge cycles at the factory and full battery performance should be realized after the first charge. _ Recharge the battery only in the Site Master, or in an Anritsu approved charger. _ If left unused, a fully charged battery will discharge itself over time. _ Storing the battery in extreme hot or cold places will reduce the capacity and lifetime of the battery. The battery will discharge faster at higher ambient temperatures (see Figure 2-9). _ Discharge an NiMH battery from time to time to improve battery performance and battery life. _ The battery can be charged and discharged hundreds of times, but it will eventually wear out. _ The battery may need to be replaced when the operating time between charging is noticeably shorter than normal. _ If a battery is allowed to totally discharge, the smart-memory capability of the battery may be lost, resulting in incorrect battery capacity readings or loss of communication with the battery. _ Do not short-circuit the battery terminals. _ Do not drop, mutilate or attempt to disassemble the battery. _ Never use a damaged or worn out charger or battery. _ Always use the battery for its intended purpose only. _ Temperature extremes will affect the ability of the battery to charge. Allow the battery to cool down or warm up as necessary before use or charging. _ Battery storage is recommended at less than 45 _ C. _ Batteries must be recycled or disposed of properly. Do not place batteries in the trash. _ Do not dispose of batteries in a fire!

2-26
Chapter 2 Functions and Operations

Chapter 3 Getting Started


Introduction
This chapter provides a brief overview of the Anritsu Site Master. The intent of this chapter is to provide the user with a starting point for making basic cable and antenna analyzer measurements.

Power On Procedure
The Anritsu Site Master is capable of up to 1.5 hours of continuous operation from a fully charged, field-replaceable battery. Built-in energy conservation features allow battery life to be extended. The Site Master can also be operated from an external DC source (which will also simultaneously charge the battery). This can be achieved with either the Anritsu AC-DC Adapter (P/N 40-168-R) or the Automotive Cigarette Lighter Adapter (P/N 806-141). Both items are included as standard accessories (see Chapter 1). To power on the Site Master: Step 1. Press the ON/OFF front panel key (Figure 3-1). Step 2. The Site Master will display the model number, the firmware revision, the internal temperature and voltage, and then perform a five second self test. At completion of the self-test, the screen displays a prompt to press ENTER to continue. If enter is not pressed, the Site Master will continue after a five second timeout. Step 3. Press ENTER to continue. The Site Master is now ready for operation.

3-1
ON/OFF KEY
HOLD RUN

START CAL AUTO SCALE SAVE SETUP RECALL SETUP LIMIT MARKER
SAVE DISPLAY RECALL DISPLAY

PRINT

MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS


ENTER CLEAR ESCAPE ON OFF

/
12

4 56 78 90 3
+.

S332D

Figure 3-1. Site Master On/Off Key

Cable and Antenna Analyzer Mode


Selecting the Frequency
For the OSL or FlexCal calibration method the frequency range for the desired measurement must be set. The Site Master will automatically set the frequency when a particular signal standard is selected, or the frequency can be manually set using the F1 and F2 soft keys. To set the frequency to a specific signal standard for an OSL or FlexCal calibration: Step 1. Press the FREQ/DIST key. Step 2. Press the Signal Standard soft key. Step 3. Use the Up/Down arrow key to highlight the desired standard, then press the ENTER key to select. To manually select the frequency range for an OSL or FlexCal calibration:

Step 1. Press the FREQ/DIST key. Step 2. Press the F1 soft key. Step 3. Enter the desired start frequency using the key pad or the Up/Down arrow key. Step 4. Press ENTER to set F1 to the desired frequency. Step 5. Press the F2 soft key. Step 6. Enter the desired stop frequency using the keypad or the Up/Down arrow key. Step 7. Press ENTER to set F2 to the desired frequency. Step 8. Check that the start and stop frequencies displayed match the desired measurement range.

Calibration
Calibration Methods For accurate results, the Site Master must be calibrated before making any measurements. The Site Master must be re-calibrated whenever the setup frequency changes, the temperature exceeds the calibration temperature range or when the test port extension cable is removed or replaced. The two methods of calibrating the Site Master, FlexCal and OSL calibration, can each be accomplished with either discrete components or with the InstaCal Module, providing four calibration techniques for maximum user flexibility. FlexCal is a broadband frequency calibration that remains valid if the frequency is changed. An OSL calibration is an Open, Short and Load calibration for a selected frequency range, and is no longer valid if the frequency is changed. The default calibration mode is OSL. With either calibration method, the Site Master may be calibrated manually with Open, Short, Load (OSL) calibration components, or by using the InstaCal module.

3-2
Chapter 3 Getting Started If a Test Port Extension Cable is to be used, the Site Master must be calibrated with the Test Port Extension Cable in place. The Test Port Extension Cable is a phase stable cable and is used as an extension cable on the test port to ensure accurate and repeatable measurements. This phase stable cable can be moved and bent while making a measurement without causing errors in the measurement. NOTE: The test port extension cable should have the appropriate connectors for the measurement. Use of additional connector adapters after the test port extension cable can contribute to measurement errors not compensated for during calibration.

Calibration Verification
During the calibration process in Return Loss mode, either with discrete calibration components or with the InstaCal module, there are typical measurement levels expected. Verifying the measurement levels displayed on the screen during calibration can save valuable time in the field. Trace Characteristics in Return Loss Mode As the discrete calibration components are connected to the Site Master RF out port, the following measurement levels will be displayed on the screen: When an OPEN is connected, a trace will be displayed between 0-10 dB. When a SHORT is connected, a trace will be displayed between 0-10 dB. When a LOAD is connected, a trace will be displayed between 0-50 dB. When an InstaCal module is connected to the Site Master RF out port, the following measurement levels will be displayed on the screen: When the Site Master is measuring an equivalent OPEN, a trace will be displayed between 0-20 dB. When the Site Master is measuring an equivalent SHORT, a trace will be displayed between 0-20 dB. When the Site Master is measuring an equivalent LOAD, a trace will be displayed between 0-50 dB. The following procedures explain standard OSL, FlexCal, and InstaCal calibration methods. Refer to Figure 3-2 for a calibration setup diagram.

Chapter 3 Getting Started

3-3
OSL Calibration Procedures
In Cable and Antenna Analyzer Mode, if the Cal Off message is displayed, or the test port cable has been changed, a new calibration is required. The following procedures detail how to perform the OSL calibration. Standard OSL Calibration Step 1. Select OSL Cal by pressing the SYS key, followed by the Application Options soft key. The currently selected calibration method is indicated at the bottom of the status window. Use the CAL Mode soft key to select the OSL calibration method. Step 2. Select the appropriate frequency range, as described on page 3-2. Step 3. Press the START CAL key. The message Connect OPEN or INSTACAL module to RF Out Port will appear in a message box, with the calibration type in the message box title bar. Step 4. Connect the calibrated Open and press the ENTER key. The messages Measuring OPEN and Connect SHORT to RF Out will appear. Step 5. Remove the Open, connect the calibrated Short and press the ENTER key. The messages Measuring SHORT and Connect LOAD to RF Out will appear. Step 6. Remove the Short, connect the calibrated Termination and press the ENTER key. The message Measuring LOAD will appear. An audible tone will sound when the calibration is complete. Step 7. Verify that the calibration has been properly performed by checking that the Cal ON message is now displayed in the upper left corner of the display.

3-4
Chapter 3 Getting Started
HOLD RUN START CAL AUTO SCALE SAVE SETUP RECALL SETUP LIMIT MARKER SAVE DISPLAY RECALL DISPLAY PRINT

MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS


ENTER CLEAR ESCAPE ON OFF

/
12

4 56 78 90 3
+.

S332D
OPEN LOAD SHORT CALIBRATION

RFOUT/REFLECTION TEST PORT TEST PORT CABLE (OPTIONAL)

Figure 3-2. Calibration Setup

FlexCal OSL Calibration Step 8. The currently selected calibration method can be viewed by pressing the SYS key, followed by the Status soft key. To change the calibration method, select the SYS key, followed by the Application Options soft key. Use the CAL Mode soft key to select the FlexCal calibration mode. Step 9. Press the START CAL key. The message Connect OPEN or INSTACAL module to RF Out Port will appear in a message box, with the calibr ation type in the message box title bar. Step 10. Connect the calibrated Open and press the ENTER key. The messages Measuring OPEN and Connect SHORT to RF Out will appear and the frequency is automatically set by the Site Master from 25 MHz to 4000 MHz. Step 11. Remove the Open, connect the calibrated Short and press the ENTER key. The messages Measuring SHORT and Connect LOAD to RF Out will appear. Step 12. Remove the Short, connect the calibrated Termination and press the ENTER key. The message Measuring LOAD will appear. An audible tone will sound when the calibration is complete.

Step 13. Verify that the calibration has been properly performed by checking that the FlexCal ON message is now displayed in the upper left corner of the LCD.

InstaCal Module Verification


Verifying the InstaCal module before any line sweeping measurements is critical to the measured data. InstaCal module verification identifies any failures in the module due to circuitry damage or failure of the control circuitry. This test does not attempt to characterize the InstaCal module, which is performed at the factory or the service center. The performance of the InstaCal module can be verified by the Termination method or the Offset method. The termination method is the preferred method in the field, and is similar to testing a bad load against a known good load. Termination Method The Termination method compares a precision load against the InstaCal module and provides a baseline for other field measurements. A precision load provides better than 42 dB directivity. Step 1. Set the frequency according to the device under test (cellular, PCS, GSM). Step 2. Press the MODE key and select Freq-Return Loss mode. Step 3. Connect the InstaCal module to the Site Master RF Out port and calibrate the Site Master using the InstaCal module (page 3-6). Step 4. Remove the InstaCal module from the RF Out port and connect the precision load to the RF Out port. Step 5. Measure the return loss of the precision load. The level should be less than 35 dB across the calibrated frequency range. Step 6. Press the MARKER key and set the M1 marker to Marker To Peak. The M1 value should be less than 35 dB return loss. Step 7. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER. Chapter 3 Getting Started

3-5
Offset Method An alternative to the termination method is to measure the return loss of a 20 dB offset. This is similar to measuring an antenna that has been specified to have a 20 dB return loss across the frequency of operation. A 20 dB offset provides a 20 dB return loss across a very wide frequency range. Measuring the return loss with the 20 dB offset will provide a relatively flat response across the operating frequency range of the Site Master. Step 1. Set the frequency according to the device under test (cellular, PCS, GSM). Step 2. Press the MODE key and select Freq-Return Loss mode. Step 3. Connect the InstaCal module to the Site Master RF Out port and calibrate the Site Master using the InstaCal module (page 3-6). Step 4. Remove the InstaCal module from the RF Out port and connect the 20 dB Offset to the RF Out port. Step 5. Measure the return loss of the 20 dB Offset. The level should be 20 dB, _2 dB across the calibrated frequency range. Step 6. Press the MARKER key and set the M1 marker to Marker To Peak. The M1 value should be approximately 20 dB return loss. Step 7. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER.

InstaCal Module Calibration Procedures


NOTE: The InstaCal module is not a discrete calibration component and it can not be used at the top of the tower to perform line sweep measurements. Check that the CAL Off message is displayed in the upper left corner of the status window. This indicates that the Site Master has not been calibrated. The following procedures detail how to perform a calibration using the InstaCal module.

3-6
Chapter 3 Getting Started
InstaCal

InstaCal MODULE
Model ICN50 10M Hz-4.0GHz HOLD RUN

START CAL AUTO SCALE

SAVE SETUP RECALL SETUP LIMIT MARKER


SAVE DISPLAY RECALL DISPLAY

PRINT MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS ENTER CLEAR ESCAPE ON OFF

/ 12 4 56 78 90 3
+-

S332D

Figure 3-3. InstaCal Module Calibration

Standard InstaCal Calibration Step 1. Select OSL Cal by pressing the SYS key, followed by the Application Options soft key. The currently selected calibration method is indicated at the bottom of the status window. Use the CAL Mode soft key to select the OSL calibration method. Step 2. Select the appropriate frequency range, as described on page 3-2. Step 3. Press the START CAL key. The message Connect OPEN or InstaCal to RF Out port will appear in a message box, with the calibration type in the message box title bar. Step 4. Connect the InstaCal module to the RF Out port (Figure 3-3). Step 5. Press the ENTER key. The Site Master senses the InstaCal module and automatically calibrates the unit using the OSL procedure. The calibration should take about 45 seconds. An audible tone will sound when the calibration is complete. Step 6. Verify that the calibration has been properly performed by checking that the Cal On! message is displayed in the upper left corner of the status window. FlexCal InstaCal Calibration Step 1. Select FlexCal by pressing the SYS key, followed by the Application Options soft key. The currently selected calibration method is indicated at the bottom of the status window. Use the CAL Mode soft key to select the FlexCal calibration method. Step 2. Press the START CAL key. The message Connect OPEN or InstaCal to RF Out port will appear in a message box, with the calibration type in the message box title bar. Step 3. Connect the InstaCal module to the RF Out port (Figure 3-3). The Site Master automatically sets the frequency from 25 MHz to 4000 MHz. Step 4. Press the ENTER key. The Site Master senses the InstaCal module and automatically calibrates the unit using the OSL procedure. The calibration should take about 45 seconds. An audible tone will sound when the calibration is complete. Step 5. Verify that the calibration has been properly performed by checking that the FlexCal On! message is displayed in the upper left corner of the status window.

Calibration with the Test Port Extension Cable


If a Test Port Extension Cable is to be used, the Site Master must be calibrated with the Test Port Extension Cable in place. Follow the same calibration procedures as above with the OSL components or the InstaCal module in place at the end of the test port extension cable. Chapter 3 Getting Started

3-7
Auto Scale
The Site Master can automatically set the scale to the minimum and maximum values of the measurement on the y-axis of the graph. This function is particularly useful for measurements in SWR mode. To automatically set the scale, press the AUTO SCALE key. The Site Master will automatically set the top and bottom scales to the minimum and maximum values of the measurement with some margin on the y-axis of the LCD.

Amplitude Scale
The following procedure sets the top and bottom scale display. Step 1. Press the AMPLITUDE key to call up the Scale Menu. Step 2. Press the Top soft key and use the keypad or Up/Down arrow key to edit the top scale value. Press ENTER to set.

Step 3. Press the Bottom soft key and use the keypad or Up/Down arrow key to edit the bottom scale value. Press ENTER to set. NOTE: Typically the y-axis scale of the graph is 0-60 dB (return loss) but for some measurements (for example, insertion loss) the scale may be changed to 0-10 dB. If the scale is not changed, some measurement results may not be easily viewed on the screen.

Set the Distance and Cable Type


In Distance-To-Fault (DTF) mode, the length of the transmission line (distance) and cable type are selected. The cable type determines the velocity propagation and cable attenuation factor. The following procedure can be used to set the distance and select the appropriate cable type. NOTE: Selecting the correct cable is very important for accurate measurements and for identifying faults in the transmission line. Selecting the incorrect cable, or using the correct cable out of its proper frequency characteristics type, will shift the DTF trace vertically and horizontally making it difficult to accurately locate faults. Step 1. Press the MODE key. Step 2. Select DTF Return Loss or DTF SWR mode. The Site Master automatically sets D1 to zero. Step 3. Press the D2 soft key. Step 4. Enter the appropriate D2 value for the maximum length of the transmission line and press the ENTER key to set the D2 value. Step 5. Press the DTF Aid soft key.

3-8
Chapter 3 Getting Started Step 6. Using the Up/Down arrow key, select the Cable = and press ENTER. Use the Up/Down arrow key to select the Standard cable types stored in the standard Site Master cable lists (which cannot be edited) or choose Custom, for additional cables. A custom cable list can be created and uploaded using the Handheld Software Tools application provided with the Site Master (Chapter 10). Step 7. Using the Up/Down arrow key, select the appropriate type of cable and press the ENTER key. The selected cable type, Prop Vel and Cable Loss in dB/m (or dB/ft) will be displayed on the DTF parameters screen. Step 8. Press ENTER. Chapter 3 Getting Started

3-9

All Modes
Save and Recall a Setup
Saving a Setup
Saving a cable and antenna analyzer setup configuration in memory will preserve the calibration information. Step 1. To save the configuration in one of the available user setup locations, press SAVE SETUP. There are ten locations in cable and antenna analyzer modes. Step 2. Use the key pad or the Up/Down arrow key to select a location. Step 3. Press ENTER to save the setup. NOTE: For cable and antenna analyzer modes, an OSL calibration is saved with an OSL designation, an InstaCal OSL calibration is saved with an OSL!, a FlexCal OSL calibration is saved with an FLX, and an InstaCal FlexCal calibration is saved with an FLX!.

Recalling a Setup
The following procedure recalls a setup from memory. Step 1. Press the RECALL SETUP key. Step 2. Select the desired setup using the Up/Down arrow key.

Step 3. Press ENTER to recall the setup. NOTE: Only setups from the current mode are displayed.

Save and Recall a Display


Saving a Display
The following procedure saves a display to memory. Step 1. Press the SAVE DISPLAY key to activate the alphanumeric menu for trace storage. Step 2. Use the soft keys to enter a label for the saved trace. For example, to save a display with the name TX1 RETURN LOSS press the soft key group that contains the letter T then press the T soft key. Press the soft key group that contains the letter X then press the X soft key. Press the number 1 key on the numeric keypad. Use the soft keys and keypad as necessary to enter the entire name, then press ENTER to complete the process.

3-10
Chapter 3 Getting Started NOTES: More than one trace can be saved using the same alphanumeric name, as traces are stored chronologically, using the time/date stamp. Pressing the SAVE DISPLAY key will bring up the last saved trace name on the input line. Pressing the Delete soft key will erase the entire trace name. To erase only one character of a trace name, press the Up/Down arrow key to select the character, then press the Delete soft key. This feature can be useful when naming traces sequentially, such as: Trace 1, Trace 2, etc.

Recalling a Display
The following procedure recalls a previously saved display from memory. Step 1. Press the RECALL DISPLAY key. Step 2. Select the desired display using the Up/Down arrow key. Step 3. Press ENTER to recall the display.

Changing the Units


By default, the Site Master displays information in metric units. Use the following procedure to change the display to English units when in cable and antenna analyzer mode. Step 1. Press the SYS key. Step 2. Select the System Options soft key. Step 3. Press the Units soft key to change from metric to English measurement units, or vice versa. The current selection is displayed at the bottom left corner of the screen.

Changing the Language


By default, the Site Master displays messages in English. To change the display language: Step 1. Press the SYS key. Step 2. Select the Language soft key. Step 3. Select the desired language. Choices are English, French, German, Spanish, Chinese, and Japanese. The default language is English.

Adjusting Markers
Step 1. Press the MARKER key to call up the Markers menu. Step 2. Press the M1 soft key to select the M1 marker function. Step 3. Press the Edit soft key and enter an appropriate value using the keypad or Up/Down arrow key to move the marker without redrawing the trace. Pressing the ON/OFF soft key activates or deactivates the M1 marker function. Step 4. Press the Back soft key to return to the Markers Menu. Step 5. Repeat the steps for markers M2, M3, M4, M5 and M6. Chapter 3 Getting Started

3-11
Adjusting Limits

The Site Master offers two types of limits: a single horizontal limit line and segmented limits. Adjusting a Single Limit Step 1. Press the LIMIT key. Step 2. Press the Single Limit soft key. Step 3. Press the Edit soft key. Step 4. Either enter the value using the numeric keypad or scroll the limit line using the Up/Down arrow key. Step 5. Press ENTER to set the location of the limit line. Adjusting Segmented Limits Segmented limit lines are defined separately as five upper limit segments and five lower limit segments. This allows the definition of a spectral mask. A limit segment is defined by its end points. That is, starting frequency, starting amplitude, ending frequency, and ending amplitude. This procedure describes the setting of two upper limit segments. The steps can be carried over to the other upper limit segments as well as to the lower limit segments. Step 1. Press the LIMIT key. Step 2. Press the Multiple Upper Limits soft key. Step 3. Press the Segment 1 soft key. Step 4. Press the Edit soft key. The status window will successively display the value of the segment endpoints: Start Freq, Start Limit, End Freq, End Limit. Step 5. Edit each value using the numeric keypad or scroll the limit line using the Up/Down arrow key and press ENTER to set. Step 6. Press the Next Segment soft key to move on to Segment 2. If the status of Segment 2 is OFF, pressing the Next Segment soft key will automatically set the start point of segment 2 equal to the end point of Segment 1. Step 7. Repeat these steps for the remaining segments. Step 8. When the final segment is defined, press the Back soft key to end the editing process.

3-12
Chapter 3 Getting Started NOTES: The Site Master does not allow overlapping limit segments of the same type. That is, two upper limit segments cannot overlap and two lower limit segments cannot overlap. The Site Master also does not allow vertical limit segments. A limit segment in which the start and end frequencies are the same, but the limit values are different, cannot be specified. Enabling the Limit Beep Both limit types can indicate a limit violation by enabling the Limit Beep. An audible "beep" will sound at each data point that violates the defined limit. Step 1. Press the LIMIT key (numeric keypad number 7). Step 2. Press the Limit Beep soft key. The status window will indicate that the status of the limit beep is On, and the soft key will remain in the "down" state. Press the Limit Beep soft key again to disable the limit beep.

Adjusting the Display Brightness


The brightness of the display can be adjusted to accommodate varying light conditions and to help discern traces. Step 1. Press the light bulb key (numeric keypad number 1). Step 2. Adjust the brightness using the Up/Down arrow key. Step 3. Press ENTER to save the new setting. Chapter 3 Getting Started

3-13

Printing
Printing is accomplished by selecting an available printer and pressing the print key as described

below. Refer to the particular printer operating manual for specific printer settings.

Printing a Screen
Step 1. Obtain the desired measurement display. Step 2. Press the SYS key and the System Options soft key. Step 3. Press the Printer soft key and select from the displayed menu of supported printers. Step 4. Press the PRINT key. Step 5. Connect the printer as shown in Figure 3-4.

Printer Switch Settings


Set the switches on the serial-to-parallel interface cable to the HP Deskjet 450 ink jet printer as follows:

3-14
Chapter 3 Getting Started
HP DESKJET PRINTER SERIAL-TO-PARALLEL SITE MASTER INTERFACE CABLE
HOLD RUN START CAL AUTO SCALE SAVE SETUP RECALL SETUP LIMIT MARKER SAVE DISPLAY RECALL DISPLAY PRINT MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS ENTER CLEAR ESCAPE ON OFF

/ 12 4 56 78 90 3
+.

S332D

Figure 3-4-. Site Master Printer Setup SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 OFF ON OFF OFF OFF OFF ON OFF

Using the Soft Carrying Case


The soft carrying case has been designed such that the strap can be unsnapped to allow the case to be easily oriented horizontally; thus allowing the Anritsu controls to be more easily accessed (Figure 3-5). Chapter 3 Getting Started

3-15
Figure 3-5. Using the Site Master Soft Carrying Case

Chapter 4 Cable and Antenna Analyzer Measurements


Introduction
This chapter provides a description of cable and antenna analyzer measurements, including line sweeping fundamentals and line sweeping measurement procedures, available when the Site Master is in frequency or DTF mode.

Line Sweep Fundamentals


In wireless communication, the transmit and receive antennas are connected to the radio through a transmission line. This transmission line is usually a coaxial cable or waveguide. This connection system is referred to as a transmission feed line system. Figure 4-1 shows an example of a typical transmission feed line system.

4-1
Figure 4-1. A Typical Transmission Feed Line System

The performance of a transmission feed line system may be affected by excessive signal reflection and cable loss. Signal reflection occurs when the RF signal reflects back due to an

impedance mismatch or change in impedance caused by excessive kinking or bending of the transmission line. Cable loss is caused by attenuation of the signal as it passes through the transmission line and connectors. To verify the performance of the transmission feed line system and analyze these problems, three types of line sweeps are required: Return Loss Measurement Measures the reflected power of the system in decibels (dB). This measurement can also be taken in the Standing Wave Ratio (SWR) mode, which is the ratio of the transmitted power to the reflected power. Cable Loss Measurement Measures the energy absorbed, or lost, by the transmission line in dB/meter or dB/ft. Different transmission lines have different losses, and the loss is frequency and distance specific. The higher the frequency or longer the distance, the greater the loss. Distance-To-Fault (DTF) Measurement Reveals the precise fault location of components in the transmission line system. This test helps to identify specific problems in the system, such as connector transitions, jumpers, kinks in the cable or moisture intrusion. The different measurements are defined as: Return Loss - System Sweep A measurement made when the antenna is connected at the end of the transmission line. This measurement provides an analysis of how the various components of the system are interacting and provides an aggregate return loss of the entire system. Distance To Fault - Load Sweep A measurement is made with the antenna disconnected and replaced with a 50_ precision load at the end of the transmission line. This measurement allows analysis of the various components of the transmission feed line system in the DTF mode. Cable Loss Sweep A measurement made when a short is connected at the end of the transmission line. This condition allows analysis of the signal loss through the transmission line and identifies the problems in the system. High insertion loss in the feed line or jumpers can contribute to poor system performance and loss of coverage. This whole process of measurements and testing the transmission line system is called Line Sweeping.

4-2
Chapter 4 Cable & Antenna Measurements

CW Mode/RF Immunity
CW mode can be used to maximize sweep speeds of both frequency and DTF measurements. With CW on, sweep times can be twice as fast as with CW off. However, making measurements with CW on will reduce the instruments immunity to interfering signals. In a controlled environment, this reduced immunity should not be a problem. In the field however, there can be stray signals from nearby or co-located transmitters that can affect frequency and DTF measurements. Turning CW on and off can verify that the Site Master is reducing the interfering signals. If there is no appreciable difference, then it should be safe to make measurements with CW on. Use this feature with caution, as the later introduction of an interfering signal might be mistaken for a problem with the antenna or cable run. If CW is on during a normal RL or SWR measurement, the Site Master will be more susceptible to interfering signals. Interfering signals can make the measurement look better or worse than it really is.

Information Required for a Line Sweep


The following information must be determined before attempting a line sweep measurement: System Frequency Range, to set the sweep frequency Cable Type, to set the cable characteristics for DTF measurements Distance of the Cable Run, to set the distance for DTF measurements

Typical Line Sweep Test Procedures


This section provides typical line sweep measurements used to analyze the performance of a transmission feed line system.

System Return Loss Measurement


System return loss measurement verifies the performance of the transmission feed line system with the antenna connected at the end of the transmission line. To measure the system return loss: Required Equipment Site Master Model S331D Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50-1 or InstaCal Module ICN50B Precision Load, Anritsu SM/PL-1 Test Port Extension Cable, Anritsu 15RNFN50-1.5-R Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M) Device Under Test Transmission Feed Line with Antenna Chapter 4 Cable & Antenna Measurements

4-3
Procedure Step 1. Press the MODE key. Step 2. Select Freq-Return Loss using the Up/Down arrow key and press ENTER. Step 3. Set the start and stop frequencies, automatically by selecting a signal standard or manually using the F1 and F2 soft keys, as described on page 3-2. Step 4. Calibrate the Site Master as described on page 3-2. Step 5. Connect the Device Under Test to the Site Master. A trace will be displayed on the screen when the Site Master is in the sweep mode. Step 6. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER. NOTE: The antenna must be connected at the end of the transmission feed line when conducting a System Return Loss measurement. Figure 4-2 is an example of a typical system return loss measurement trace using a FlexCal calibration: NOTE: The system sweep trace should appear at an approximate return loss of 15 dB (_3 dB) in the status window. Typically, greater than a 15 dB return loss is measured in the passband of the antenna system.

4-4
Chapter 4 Cable & Antenna Measurements
Figure 4-2. Typical System Return Loss Trace

Cable Loss Measurement


The transmission feed line insertion loss test verifies the signal attenuation level of the cable system in reference to the specification. This test can be conducted with the Site Master in FreqCable Loss mode. Required Equipment Site Master Model S331D Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50-1 or Anritsu InstaCal Module, ICN50B Precision Load, Anritsu SM/PL-1 Test Port Extension Cable, Anritsu 15RNFN50-1.5-R Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M) Device Under Test Transmission Feed Line with Short Procedure - Cable Loss Mode Step 1. Press the MODE key. Step 2. Select Freq-Cable Loss using the Up/Down arrow key and press ENTER. Step 3. Set the start and stop frequencies, automatically by selecting a signal standard or manually using the F1 and F2 soft keys, as described on page 3-2. Step 4. Connect the Test Port Extension cable to the RF port and calibrate the Site

Master as described on page 3-2. Step 5. Save the calibration set up (page 3-10). Step 6. Connect the Device Under Test to the Site Master phase stable Test Port Extension cable. A trace will be displayed on the screen as long as the Site Master is in sweep mode. Step 7. Cable loss is displayed in the status window. Step 8. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER. Chapter 4 Cable & Antenna Measurements

4-5
Figure 4-3 is an example of a typical transmission line cable loss measurement trace using a standard calibration.

4-6
Chapter 4 Cable & Antenna Measurements
Figure 4-3. Typical Transmission Line Cable Loss Trace

Distance-To-Fault (DTF) Transmission Line Test


The Distance-To-Fault transmission line test verifies the performance of the transmission line assembly and its components and identifies the fault locations in the transmission line system. This test determines the return loss value of each connector pair, cable component and cable to identify the problem location. This test can be performed in the DTF Return Loss or DTFSWR mode. Typically, for field applications, the DTFReturn Loss mode is used. To perform this test, disconnect the antenna and connect the load at the end of the transmission line. Required Equipment Site Master Model S331D Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50-1 or Anritsu InstaCal Module, ICN50B Precision Load, Anritsu SM/PL-1 Test Port Extension Cable, Anritsu 15RNFN50-1.5-R Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M) Device Under Test Transmission Feed Line with Load Procedure - DTF - Return Loss Mode The following steps explain how to make a DTF measurement in return loss mode. Step 1. Press the MODE key. Step 2. Select DTF-Return Loss using the Up/Down arrow key and press ENTER. Step 3. Connect the Test Port Extension cable to the RF port and calibrate the Site Master as described on page 3-2. Step 4. Save the calibration set up (page 3-10). Step 5. Connect the Device Under Test to the Site Master phase stable Test Port Extension cable. A trace will be displayed on the screen as long as the Site Master is in sweep mode. Step 6. Press the FREQ/DIST key. Step 7. Set the D1 and D2 values. The Site Master default for D1 is zero. Step 8. Press the DTF Aid soft key and select the appropriate Cable Type to set the correct propagation velocity and attenuation factor. NOTE: Selecting the right propagation velocity, attenuation factor and distance is very important for accurate measurements, otherwise the faults can not be identified accurately. Step 9. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER. Step 10. Record the connector transitions. Chapter 4 Cable & Antenna Measurements

4-7
Figure 4-4 shows an example of a typical DTF return loss measurement trace using a

FlexCal calibration. In the above example: Marker M1 marks the first connector, the end of the Site Master phase stable Test Port Extension cable. Marker M2 marks the first jumper cable. Marker M3 marks the end of the main feeder cable. Marker M4 is the load at the end of the entire transmission line. Procedure - DTF-SWR Mode The following steps explain how to measure DTF in SWR mode. Step 1. Press the MODE key. Step 2. Select the DTF-SWR using the Up/Down arrow key and press ENTER. Step 3. Follow the same procedure as DTF-Return Loss mode, above.

Resolution
There are three sets of data points (130, 259 and 517) available in the Site Master. The factory default is 259 data points. By increasing the number of data points the measurement accuracy and transmission line distance to measure will increase. Step size = (1.5108)(Vp) F Where Vp is the relative propagation velocity of the cable and F is the stop frequency minus the start frequency (Hz). The maximum distance is: Dmax = step size _ (# of datapoints 1)

4-8
Chapter 4 Cable & Antenna Measurements
Figure 4-4. Typical DTF Return Loss Trace

Increasing the data points increases the sweep time and increases the accuracy of the measurement. CW mode On or Off can also affect sweep speed (see CW Mode, page 4-3 for details).

Antenna Subsystem Return Loss Test


Antenna Subsystem return loss measurement verifies the performance of the transmit and receive antennas. This measurement can be used to analyze the performance of the antenna before installation. The antenna can be tested for the entire frequency band, or tested to a specific frequency range. Transmit and receive frequency measurements are conducted separately. The following steps explain how to measure the antenna loss in return loss mode. Required Equipment Site Master Model S331D Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50-1 or Anritsu InstaCal Module, ICN50B Precision Load, Anritsu SM/PL-1 Test Port Extension Cable, Anritsu 15RNFN50-1.5-R Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M) Device Under Test Antenna Sub Assembly Procedure Step 1. Press the MODE key. Step 2. Select Freq-Return Loss using the Up/Down arrow key and press ENTER. Step 3. Connect the Test Port Extension cable to the RF port and calibrate the Site Master as described on page 3-2. Step 4. Press SAVE SETUP and save the calibration set up (page 3-10). Step 5. Connect the Device Under Test to the Site Master phase stable Test Port Extension cable. Step 6. Press the MARKER key. Step 7. Set markers M1 and M2 to the desired frequencies. Step 8. Record the lowest return loss over the specified frequency range.

Step 9. Press SAVE DISPLAY (page 3-10) name the trace, and press ENTER. Chapter 4 Cable & Antenna Measurements

4-9
The following trace is an example of an antenna return loss measurement trace using a FlexCal calibration.. Calculate the threshold value and compare the recorded Lowest Return Loss to the calculated threshold value. Maximum Return Loss =


20 1 1 log VSWR VSWR NOTES: VSWR is the antenna manufacturers specified VSWR. Use Handheld Software Tools to convert VSWR to Return Loss, or Return Loss to VSWR. If the measured return loss is less than the calculated threshold value, the test fails and the antenna must be replaced.

4-10
Chapter 4 Cable & Antenna Measurements
Figure 4-5. Antenna Return Loss Trace

Chapter 5 Power Monitor Mode


Introduction
The Site Master with Option 5 installed can be used for making power measurements with broadband RF detectors, such as the 10 MHz to 20 GHz Anritsu 560-7N50B. See the table of available RF detectors on page 1-3. The power monitor displays the measured power results in dBm or Watts.

Power Measurement
Required Equipment Site Master Model S331D with Power Monitor option Broadband RF detector, Anritsu P/N 5400-71N50 30 dB, 50 Watt, bi-directional, DC 18 GHz, N(m) N(f), Attenuator, 42N50A-30 Procedure Step 1. Press the ON/OFF key on the Site Master. Step 2. Press the MODE key. Step 3. Use the Up/Down arrow key to select the Power Monitor mode and press ENTER. Zeroing the Power Monitor Step 4. With no power applied to the DUT, press the ZERO soft key from the Power menu. Wait for a few seconds while the Site Master accumulates data samples of the quiescent power. When complete, ZERO ADJ: On is displayed in the message area. Measuring High Input Power Levels Step 5. Insert an attenuator between the DUT and the RF detector to protect the Site Master so that the input power level is less than or equal to 20 dBm.

Step 6. Press the OFFSET soft key. Step 7. Enter the attenuation in dB using the keypad. Press the ENTER key to complete the entry. The message area will show REL: ON along with the entered value in dB. Displaying Power in dBm and Watts Step 8. Press the UNITS soft key to display power in Watts.

5-1
Displaying Relative Power Step 9. With the desired base power level input to the Site Master, press the REL soft key. The message area will show REL: ON and the power reading will indicate 100%. Step 10. Press the UNITS soft key to display power in dBm. Since REL is ON, the power reading will be in dBr, relative to the base power level.

5-2
Chapter 5 Power Monitor

Chapter 6 High Accuracy Power Meter


Introduction
Anritsu's High Accuracy Power Meter (Option 19) enables high accuracy, RMS measurements for both CW and digitally modulated signals such as CDMA/EV-DO, GSM/EDGE, and WCDMA/HSDPA. This option requires either the PSN50 or MA24104A power sensors. The PSN50 power sensor provides high accuracy terminating measurements from 50 MHz to 6 GHz with a dynamic range from 30 dBm to +20 dBm. The MA24104A is an Inline High Power sensor with a frequency range from 600 MHz to 4 GHz and can measure signals as high as 150W. Both of the power sensors are equipped with an RS232 interface for fast and easy connection to the Site Master.

Units and Relative Power


The display shows the power values in both dBm and Watts. The Relative Power feature displays power changes with respect to a reference value in both dB and %.

Limit Lines
Limits can be used to determine if a measurement is within specified limits, and running averaging is available along with Max/Hold and Run/Hold.

Connecting the Sensor


The Option 19 High Accuracy Power Meter connects to the PSN50 or MA24104A power sensor using an RS232 cable (Anritsu part number 800-441). A 9 to 18 VDC (<100 mA) power supply is needed to power either sensor (the MA24104A power sensor can also be powered with three AA batteries). Anritsu power supply (40-168-R), supplied with the Site Master, is recommended.

6-1
Figure 6-1. High Accuracy Power Measurement Display

Zeroing the Sensor


The zero feature improves low-level accuracy by removing measured system noise. Cal Factors correct both efficiency and mismatch loss. The frequency information must be entered to obtain the correct calibration factor.

Using Attenuators
When necessary, attenuators should be used to ensure that the power does not exceed the specified measurement range. The Offset dB feature can be used to enter the value of any cables and attenuators.

Power Measurement
Required Equipment S331D Site Master RS232 Serial Cable, Anritsu P/N 800-441 Power Supply, Anritsu P/N 40-168-R PSN50 or MA24104A Power Sensor 30 dB, 50W, bi-directional, DC-8.5 GHz, N(m)-N(f), Attenuator, 3-1010-123 Procedure Step 1. Connect the RS232 serial cable between the sensor and the Site Master serial port. Step 2. Connect the DC power supply to the DC input of the PSN50 or MA24104A. Step 3. Press the ON/OFF key on the Site Master. Step 4. Press the MODE key. Step 5. Use the Up/Down arrow key to select High Accuracy Power Meter mode and press ENTER.

6-2
Chapter 6 High Accuracy Power Meter
HOLD RUN START CAL AUTO SCALE SAVE SETU P RECALL SETU P LIMIT MAR KER SAVE DISPLAY RECALL DISPLAY PRINT

MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS


ENTER CLEAR ESC APE ON OFF

/
12

4 56 78 90 3
+.

MT8212A CellMaster

S332D ATTENUATOR

DUT
RF OUT PSN50 SENSOR DC SUPPLY MA24104A SENSOR LOAD

Figure 6-2. High Accuracy Power Meter Setup

Zero and Cal Step 6. Press the FREQ/DIST key. Step 7. To enter the frequency manually using the number keys, select the Center soft key. To select a known signal standard, press the Signal Standard soft key and use the Up/Down arrow key to select the desired standard. The Cal Factors will be derived for the corresponding center frequency. NOTE: The channel number is not required because the cal factor frequencies are rounded to the nearest 500 MHz. Step 8. With no power applied to the sensor, press the AMPLITUDE key then the Zero soft key to zero the sensor. Zeroing the sensor is recommended when making power measurements below 20 dBm. Using Attenuators Step 9. Press the AMPLITUDE key and select the Offset dB soft key. Step 10. Connect the phase stable cable and the attenuator between the DUT and the sensor. Step 11. Enter the combined offset value of the attenuator and the pad, or select the Measure Offset soft key to use the Offset Cal Kit (65701) to measure the offset. See page for more details. Averaging/Max Hold/Run Hold Step 12. Press the MEAS/DISP key. Step 13. Press the Running Averages soft key and use the keypad to enter the number of averages to use (up to 50). Step 14. Press the Max Hold soft key to display the maximum value. If Averaging is selected, Max/Hold will display the maximum value of the non-averaged data. Step 15. Press the RUN/HOLD key to hold the display in the current condition.

Setting Limits Step 16. Press the MEAS/DISP key. Step 17. Press the Limit Units soft key to select the units. Step 18. Press the Lower Limit soft key and enter the lower limit value in dBm or in Watts. Step 19. Press the Upper Limit soft key and enter the upper limit value in dBm or in Watts. Step 20. Press the Limit ON/OFF soft key to turn on the limits. The number display will turn green if the measurement is passing, or red if the measurement is failing. The word PASS or FAIL will also be displayed in between the logarithmic and linear display windows. Chapter 6 High Accuracy Power Meter

6-3
Displaying Relative Power Step 21. Press the AMPLITUDE key. Step 22. With the desired base power level input to the sensor, press the Rel soft key. The message area will show Relative On and the power reading will show 0 dB and 100%. If measuring a 10 dBm signal with the Rel key selected, a drop to 7 dBm will show 3dB and 50%. Saving the Measurement Step 23. Press the SAVE DISPLAY key. Step 24. Use the soft keys to enter a Trace Name. Transferring Data to Handheld Software Tools The Site Master has only one serial port, so it is not possible to communicate with both the PSN50 sensor and a PC running Handheld Software Tools (HHST) at the same time. Therefore, only saved measurements can be viewed in HHST when using the PSN50. To view saved measurements, disconnect the serial cable from the PSN50 and connect it to the serial port of the PC running HHST. Refer to the Handheld Software Tools chapter in this manual for further information.

6-4
Chapter 6 High Accuracy Power Meter

Chapter 7 Handheld Software Tools


Introduction
This chapter provides a description of the Anritsu Handheld Software Tools (HHST) program. Handheld Software Tools is a Windows 95/98/NT4/2000/ME/XP/Vista program for transferring measured traces, along with markers and limit lines, to the PC display. The program help function provides on screen instructions on display modification, trace overlay, uploading and downloading traces, and multiple plot printing. NOTE: Master Software Tools (MST) now works with the Site Master S331D. We strongly recommend users to migrate to MST. This platform has numerous productivity advantages over HHST and all future product enhancements will be done via MST. See Chapter 8 for more information on MST.

Features
Handheld Software Tools provides the following features: Download traces saved in the instrument memory to the PC for storage and analysis Upload traces from the PC to the instrument memory Trace Overlay allows the viewing of three plots simultaneously Ability to save captured plots as data files (.dat file format) or as records representing

site information in a database file Ability to export plot data as text files for use in a spreadsheet (.txt file format) Ability to save captured plots as graphic files (.wmf file format) Ability to zoom in or out to analyze a particular region of the plot Ability to modify Plot Properties Ability to output plots to a printer for hard copy records Capture the current trace on the unit Create custom cables to be uploaded to the instrument Create new signal standards to be uploaded to the instrument Create new waveguides to be uploaded to the instrument

7-1

System Requirements
The Handheld Software Tools program will run on most any computer running Windows 95/98/NT4/2000/ME/XP/Vista. Minimum requirements and recommendations are: Intel Pentium 100 MHz microprocessor (Pentium II 350 MHz or better recommended) 16 MB of RAM (64 MB or above recommended) Hard disk drive with approximately 15 MB of available space (An additional 20 MB free space for storage of captured plots is recommended.) A serial (COM) port or a USB port and USB power adapter cable for communication with the instrument NOTE: It is recommended that Windows NT 4.0 users install NT 4.0 Service Pack 3 (SP3) or above. In addition, Windows 2000 (SP1 or higher) and Windows ME may require installation of the latest Service Pack. Please contact Microsoft Corporation for further information on obtaining and installing service packs.

Installation
To install the Handheld Software Tools program: Step1. Insert the Anritsu Handheld Software Tools disk in the CD-ROM drive. Step2. From the Windows Start menu, select Run. Step3. Type: X:\Setup.exe where X is the drive letter of your CD-ROM drive. Step4. When prompted, press the Enter key to accept the default directory C:\Program Files\ Software Tools and the installation will begin. The readme.doc file on the disk provides updated information about the program, and the Help function provides detailed operating information.

7-2
Chapter 7 Handheld Software Tools

Communication Port Setting


The Handheld Software Tools communicates with the instrument through a standard serial COM port on the PC. Set the baud rate of the COM port to 115200. Step1. Select Start, Programs and select Software Tools. Step2. When the program has loaded, select Settings, Communication. Step3. Select the appropriate PC COM port and Transfer Baud Rate for your system, and click OK. (For the optional USB Adapter Cable (551-1691) set the COM port to COM 4, and the baud rate to 38400.) Chapter 7 Handheld Software Tools

7-3
Figure 7-1. Communication Setting Dialog Box

Interface Cable Installation


Communication between the instrument and the PC is accomplished over a null modem serial cable provided with the instrument (Anritsu part number 800-441, and optional USB to serial adapter, part number 551-1691, if required). Step1. Install the null modem serial interface cable to the RS232 Serial Interface connector

on the test connector panel. Step2. Connect the other end of the serial interface cable to the appropriate COM port connector on the PC. Step3. Turn on both the instrument and the PC.

7-4
Chapter 7 Handheld Software Tools
HOLD RUN START CAL AUTO SCALE SAVE SETUP RECALL SETUP LIMIT MARKER SAVE DISPLAY RECALL DISPLAY PRINT

MODE FREQ/DIST AMPLITUDE MEAS/DISP SYS


ENTER CLEAR ESCAPE ON OFF

/ 12 4 56 78 90 3
+.

S332D

COM PORT SERIAL INTERFACE

Figure 7-2. Serial Cable Connection

Using Handheld Software Tools


Select Start, Programs and select Software Tools.

Downloading Traces
Traces that can be downloaded from the instrument are grouped by the date on which they were saved. They are further organized in chronological order for each date, with the oldest trace at the top of the list. Each trace listing displays the trace name and measurement type for that trace. Available measurement types are:
Return Loss Insertion Loss SWR Insertion Gain Cable Loss Power Monitor DTF (Distance to Fault)

NOTE: Not all selections apply to every Anritsu Handheld instrument.

Plot Capture to the PC


To open the plot capture menus, select the capture icon on the button bar, or select the Capture drop down menu from the menu bar. Select Capture to Screen to download traces to the PC. Select a folder, or individual traces within a folder, to be downloaded to the PC. The traces will appear on the PC display as they are downloaded. When Software Tools is communicating with the instrument, REMOTE will be displayed to the left of the graph.

Plot Upload to the Instrument


Open a plot to be uploaded to the instrument. Plot properties can be modified on the PC before it is uploaded if desired. Select the Capture drop down menu from the menu bar. Select Upload the Current Plot to upload the plot to the instrument. The plot will be stored in the instrument non-volatile memory with the original date and time that the plot was saved. The uploaded trace can be viewed on the instrument by pressing the RECALL DISPLAY button on the instrument keypad. Chapter 7 Handheld Software Tools

7-5
Plot Properties
After downloading, certain plot properties and information can be modified. Select the Plot Properties or Plot Information icon. Plot Properties that can be changed include: Graph Titles Display Mode Scale/Limit Markers

Misc. (Plot Display Parameters) Graph Titles After downloading the plot, the Main Title can be changed to reflect the site name or other descriptive information. The Sub Title field can be used to describe the specifics of the measurement and configuration. Scale/Limit The scale of the displayed plot can be modified to help analyze whether the plot meets pass/fail criteria. The Scale/Limit sub menu activates options to manually enter the scale limits, or to use the Auto Scale mode. Manual adjustment sets the upper and lower limits of the display under the Scale/Limit Submenu. Auto Scale automatically adjusts the scale for maximum and minimum measurement readings. Limit Line Off turns off all limit lines. Single Limit Line can be activated to help identify faults. Multi-Segment Limit Lines can be activated to set different limits within the same measurement display for specification requirements. Markers Markers M1 through M6 can be activated from the Plot Properties menu. The six active markers can be displayed on the plot to help identify faults from the line sweep data.

7-6
Chapter 7 Handheld Software Tools Misc. The Miscellaneous tab allows adjustment of the Plot/Limit Line Width, the setting of the Plot Footer, and the date format. Plot/Limit Line Width can be used when preparing reports for the carrier, service providers, and network operators where the trace data must be visible and legible for documentation. The line density of the trace can be set to Normal (Thin Line) or Thick Line to make the data appear easily when copies are made. Plot Footer allows selection of information to be displayed in the trace display. Selections are: Time/Date Impedance Model and Serial Number Measurements Bias Tee DTF Parameters Date Format: mm/dd/yyy dd/mm/yyyy yyyy/mm/dd NOTE: While all possible selections are displayed, some of these selections apply only to specific models of Anritsu hand held instruments.

Trace Overlay or Plot Overlay


Trace Overlay is activated by the Mouse Function icon. Single-click on the Mouse Function icon to toggle. Toggling this icon switches the mouse function between Marker/Limit/Zoom and Plot Overlaying. To overlay two plots, click-and-drag from one plot to the other plot. The final display will be the two plots superimposed on one another. Refer to the Handheld Software Tools HELP function for more information on the steps necessary to perform a trace overlay.

Saving Traces
Once the plots are captured to the PC they can be saved as individual files or as a block of files to a database. Saving a Plot as a Windows Metafile or to a Spreadsheet Plots can be saved as a Windows metafile (.wmf), a Handheld Software Tools .dat file, a

text file (.txt) or an .mdb database. The metafile may be imported into graphic programs and the text file can be imported into a spreadsheet. The .dat and .mdb files are used exclusively by Handheld Software Tools. To save a plot as a Windows metafile, click on the File menu and select Export to Metafile from the pull down menu. Once the trace is saved as a metafile, it can be copied and transferred into other applications as a picture or graphic file. Chapter 7 Handheld Software Tools

7-7
To copy a metafile: Step1. Select the trace to be copied with the mouse cursor. Step2. Select Edit and then Copy. The file will copied to the clipboard, or select File and then Export to a Windows metafile. Step3. Open the target application (Microsoft Word, etc.). Step4. Select Edit and then Paste. The file will be inserted as a graphic file or a bitmap. Saving a Plot to a Spreadsheet Plots can be saved as a text file (.txt) which can then be imported into a spreadsheet program. To save a plot as a text file: Step1. Select the trace to be copied with the mouse cursor. Step2. Click on the File menu and select Export to Text File for a Spreadsheet from the pull down menu. Step3. Save the file to a local directory. Step4. Exit the Handheld Software Tools program and open the spreadsheet application. Step5. Import the .txt file into the spreadsheet program.

Creating a Database
A single trace or a block of traces can be transferred from the instrument to the PC. A separate database can be created for each cellular site. The site name can be used as the database name. Step1. Select the File menu and select the Database. Step2. Open an existing database or create a new database with a descriptive filename that represents the site name. Once the database has been created, files can be saved and site information can be added, such as Plot Description, Date/Time, Operator, record/trace number and session description (transmitter type, etc.) Individual plots will be labeled with the Database Site Name. Each record has its own plot description and measurement type.

Printing Formats
One to multiple plots per page can be set up under the print format in Handheld Software Tools. Orientation of how the plots are printed on the page can be changed from vertical to horizontal.

7-8
Chapter 7 Handheld Software Tools

Cable List
A custom cable list can be created in Software Tools and uploaded to the Site Master. Some standard 1000 MHz, 2000 MHz, and 2500 MHz cables are stored in the Site Master and are listed in Appendix A of this Users Guide. The cable list contains vital information such as propagation velocity (Vp) and insertion loss (dB/m or dB/ft). These parameters are important when identifying faults and discontinuities of transmission lines. NOTE: Values for the cable list are taken from manufacturers specifications. Complex digital communications systems may require adjustment to attenuation values at the higher frequencies. Contact the manufacturer for the appropriate cable losses. The Cable Editor is specifically designed to provide contractors, service providers, and network

operators with a list of cable types that are tailored to their use. To open the Cable Editor, select the Tools menu and select Cable Editor. To open an existing cable list file, select File and Open. Select the desired cable list and press Enter.

Creating a Custom Cable List


To create a custom cable list: Step1. Select the File menu and select New. Step2. Type in or cut and paste the cable types and specifications for the desired cables.

Uploading a Cable List


After custom cable list has be created in Handheld Software Tools, it can be uploaded to the Site Master. The serial communication null modem cable must be connected from the Site Master to the PC. In the Cable Editor, select Tools and Upload Cable List. The software will confirm the upload with a message "Upload Complete" when the operation is finished.

Querying the Site Master Cable List


Query Cable List allows the user to check and review the contents of the custom cable list in the Site Master. In the Cable Editor, select Tools and Query Cable List. The software will download the cable list from the Site Master to the PC.

DTF Plots
Handheld Software Tools can convert Return Loss in Frequency Domain (Freq-RL) plots and SWR in Frequency Domain (Freq-SWR) plots to DTF plots. Chapter 7 Handheld Software Tools

7-9
To convert from Frequency Domain to Distance to Fault, follow these steps: Step1. Capture a plot or load a previously saved plot. Step2. Click the Distance-to-fault button on the toolbar (or choose Distance-to-Fault from the Tools menu). A dialog will open allowing you to specify the cable parameters, start distance, and stop distance. The cable type may be selected from the pull-down list. Selecting a cable from the list automatically sets the propagation velocity and insertion loss. To manually enter the dielectric constant and insertion loss, select the Custom cable type from the top of the list. Click OK when finished. A new window will open showing the converted plot. Step3. Use the cursor to read out values shown in the bottom tray of the PC screen, at each point along the DTF trace. Maximize the plot window for best cursor resolution. NOTES: The distance units (meters or feet) can be changed by selecting Default Plot Settings from the Settings menu. The stop distance entry must be less than or equal to the maximum un-aliased range (D-Max), and the start distance must be less than the stop distance.

Smith Chart
The Smith Chart is a commonly used graphical format for the analysis of the impedance of transmission lines. It can be a useful tool for fine tuning an antenna system. Handheld Software Tools can convert the following types of plots to Smith Charts: Return Loss (Frequency Domain) VSWR (Frequency Domain) To convert a plot to a Smith Chart: Step1. Capture a plot or load a previously saved Return Loss or VSWR plot. Step2. Click the Smith Chart button on the toolbar (or choose Convert to Smith Chart from the Tools menu). A new window will open showing the plot in Smith Chart form. Step3. To read values from a Smith Chart, move the mouse pointer over a data point. When the mouse pointer turns into a hand, click once with the left button. A pop-up window will appear with various measurement data.

7-10

Chapter 7 Handheld Software Tools

Signal Standards Editor


The Signal Standards Editor is a software application for viewing, editing and creating signal standards files. Select a signal standard entry from the list to make it active. The Signal Standards Editor can: _ Create new signal standards files _ View and edit the signal standard definitions _ Copy and paste signal standard definitions _ Retrieve the signal standards file from a test unit _ Store an updated signal standards file back onto the test unit _ Generate a report of the signal standards file

Creating a New Signal Standards File


To create a new signal standards file, select New Signal Standards File from the File drop-down menu. An empty signal standards file will be displayed. To add a signal standard, select Add Signal Standard from the Edit menu. To add an existing signal standard from a different signal standards file, use the Cut, Copy and Paste icons, or select Cut, Copy and Paste from the Edit menu.

Editing a Signal Standard


A signal standard definition can be changed by editing the name and parameters. The active line of the current signal standard is displayed in the text entry box under the main toolbar. If this box is disabled, the selected signal standard can not be edited. All changes are temporary until saved as a disk file. To save the signal standards file on the local PC, select Save from the File menu.

Cut, Copy and Paste


Use the Cut, Copy and Paste icons, or select Cut, Copy and Paste from the Edit menu to add, copy or remove signal standards. Cut moves the currently selected signal standard onto the clipboard and the signal standard is deleted from the Signal Standards list. If the signal standards file is saved, the cut signal standard will be permanately deleted from that list. Copy puts a copy of the signal standard on the clipboard, but does not delete it from the current Signal Standards list. Paste copies a signal standard from the clipboard into the current Signal Standards list. Chapter 7 Handheld Software Tools

7-11
Retrieving Signal Standards Files
Connection Manager must be connected to a test unit before retrieving a Signal Standards file. An active connection is indicated in the Status Bar at the bottom right corner of the application window. To retrieve a Signal Standards file, select Retreive Signal Standards from the Connection menu, or use the short-cut icon on the button bar. The retrieved Signal Standards data will replace all existing Signal Standards data in the Signal Standards Editor. To store the current Signal Standards data locally, select Save from the File menu and save the current Signal Standards file before retrieving another the Signal Standards file from a test unit.

Storing Signal Standards Files


To upload the Signal Standards file to a test unit, select Upload Signal Standards from the Connection menu, or press the short-cut icon on the button bar. This will upload the current Signal Standards file to the test unit, overwriting any data already on the test unit.

Signal Standards Reports


A signal standards report is generated by selecting the Report function from the File menu. A signal standards report is an HTML file and can be opened inside the default web-browser of the PC, where it can be printed if desired.

7-12
Chapter 7 Handheld Software Tools

Chapter 8 Master Software Tools


Introduction
This chapter provides an introduction to the Anritsu Master Software Tools (MST) program. Users of the legacy Handheld Software Tools (HHST) program are strongly encouraged to migrate to new MST platform. This new platform has numerous productivity advantages over HHST as described below in the list of features. All future product enhancements will be implemented via MST. Master Software Tools is a suite of Microsoft Windows programs for transferring saved measurements, along with markers and limit lines, to a PC display. The programs provide the ability to modify display parameters, overlay multiple traces, upload and download traces, print traces using local or networked printers, create or modify language files, edit the cable and signal standard lists, and convert .dat files to the new .vna format. Master Software Tools requires Windows 2000 (Service Pack 4 or above), Windows XP (Service Pack 2 or above), or Windows VISTA. MST will not function on earlier versions of the Microsoft Windows operating system as the program relies on the Microsoft .NET Framework.

Key Features of Master Software Tools


File Conversion Tool this utility imports .DAT files from Handheld Software Tools and converts them to the new MST format. The .DAT file is unchanged by the process. Once converted, these new files can be opened and edited using the Measurement Editor. _ Cable Editor This application allows you to delete, modify, and add new cables to the instrument memory. _ Signal Standard Editor If there is a standard that is not included in the instrument, MST can modify, edit, and append the signal standard list. _ Product Update This feature keeps you informed of the latest instrument firmware version. _ Integrated Codeloader No need to install a separate program to upgrade instrument Firmware. Everything can be addressed with MST. _ Trace Rename Utility Allows you to rename hundreds of traces in a couple of minutes. This is a real time saver for people spending a lot of time renaming traces. _ Group Edit If you have a folder with hundreds of traces and you forgot to turn on the markers or limit lines, you can use the Group Edit tool to copy the markers and limit line from one trace to all traces in a specific folder. _ Advanced limit line editor Create and upload complex limit line masks to the instrument. _ Standard Windows File Management simplify the process of downloading, dragging, and dropping files.
_ DAT

8-1
Editor this utility allows you to add new or modify existing language tables. Languages available for selection are English, French, German, Spanish, Italian, Japanese, Chinese and Korean. All of these languages except for English can be edited. Up to two more custom languages can be loaded using this utility. _ AVI Files Create video files of your favorite Spectrogram measurement.
_ Language

8-2
Chapter 8 Handheld Software Tools
Figure 8-1. VNA measurement using the marker table Figure 8-2. Trace Rename utility enables you to rename hundreds of traces in minutes

NOTE: New firmware is not compatible with Master Software Tools version 1.25 or older. Insure that you have maximum functionality by updating your Master

Software Tools to the latest version. Chapter 8 Handheld Software Tools

8-3
Figure 8-4. DAT file conversion tool used to convert existing SPA and Cable & Antenna traces to MST Figure 8-3. MST Product Update Tools used to download the latest software and firmware

Minimum System Requirements


_ Microsoft

Windows 2000 (Service Pack 4 or above), Windows XP (Service Pack 2 or above), or Windows VISTA _ Microsoft .NET Framework, Version 2.0 _ Intel Pentium 233 MHz microprocessor (Pentium III 350 MHz or better recommenced) _ 128 MB of available RAM (256 MB or above recommended) _ Hard disk drive with approximately 80 MB of available space (an additional 80 MB free space for storage of captured plots is recommended.) _ A USB port (USB 1.2 required, USB 2.0 recommended) or an Ethernet 10/100 Base-T connection for communication with the instrument

8-4
Chapter 8 Handheld Software Tools

Appendix A Windowing
Introduction
The FREQ/DIST menu (page 2-11) provides for setting the cable loss and relative propagation velocity of the coaxial cable. The Window key opens a menu of FFT windowing types for the DTF calculation. The theoretical requirement for inverse FFT is for the data to extend from zero frequency to infinity. Side lobes appear around a discontinuity due to the fact that the spectrum is cut off at a finite frequency. Windowing reduces the side lobes by smoothing out the sharp transitions at the beginning and at the end of the frequency sweep. As the side lobes are reduced the main lobe widens thereby reducing the resolution. In situations where there may be a small discontinuity close to a large one, side lobe reduction windowing should be used. When distance resolution is critical windowing can be reduced.

Examples
The types of windowing in order of increasing side lobe reduction are: rectangular, nominal side lobe, low side lobe, and minimum side lobe. Figures A-1 thru A-4 show examples of the types of windowing.

A-1
____ _________ _ __ ___ ___ ___ ___ _ _ _ _ _ _ _ _ ___ _______________ _________________ _ _ _______

Figure A-1. Rectangular Windowing Example

A-2
Appendix A Windowing
_________________ _________ _ ____ _ _ _______ __ ___

___ ___ ___ _ _ _ _ _ _ _ _ ___ _______________

Figure A-2. Nominal Side Lobe Windowing Example


_________________ _________ _ ____ _ _ _______ __ ___ ___ ___ ___ _ _ _ _ _ _ _ _ ___ _______________

Figure A-3. Low Side Lobe Windowing Example

A-3
Appendix A Windowing
_________________ _________ _ ____ __ ___ ___ ___ ___ _ _ _ _ _ _ _ _ ___ _______________ _ _ _______

Figure A-4. Minimum Side Lobe Windowing Example

Index
A
accessories . . . . . . . . . . . . . . 1-2, 1-4

B
battery . . . . . . . . . . . . . . . . . . 2-23 brightness. . . . . . . . . . . . . . . . . 3-13

C
cable loss . . . . . . . . . . . . . . . 4-2, 4-5 calibration . . . . . . . . . . . . . . 1-10, 3-2 case. . . . . . . . . . . . . . . . . . . . 3-15 clock . . . . . . . . . . . . . . . . . . . 2-14 connectors . . . . . . . . . . . . . . . . . 2-1 CW. . . . . . . . . . . . . . . . . . . . . 4-3

D
date format . . . . . . . . . . . . 2-14 - 2-15 DTF . . . . . . . 2-11, 3-8, 4-2, 4-7, 7-5, 7-9 DTFAid. . . . . . . . . . . . . . . 2-11, 3-8

E
error messages . . . . . . . . . . . . . . 2-19 ESD . . . . . . . . . . . . . . . . . . . 1-11

F
FFT . . . . . . . . . . . . . . . . . . . . A-1 FlexCal. . . . . . . . . . . . . . . 2-14, 2-22 frequency. . . . . . . . . . . . . . . . . 2-11

frequency range . . . . . . . . . . . . . . 1-1

G
grounding . . . . . . . . . . . . . . . . . 2-1

H
hard keys. . . . . . . . . . . . . . . . . . 2-5 hold . . . . . . . . . . . . . . . . . 2-7, 2-17

I
InstaCal . . . . . . . . . . . . 1-11, 2-21, 3-2

K
keys hard . . . . . . . . . . . . . . . . . 2-5 soft . . . . . . . . . . . . . . . . . . 2-8

L
language. . . . . . . . . . . 2-14 - 2-15, 3-11 limits . . . . . . . . . . . . . . . . 2-13, 3-12 line sweep . . . . . . . . . . . . . . . . . 4-1

M
maintenance . . . . . . . . . . . . . . . 1-10 markers . . . . . . . . . . . . . . . 3-11, 7-6 measurements cable and antenna . . . . . . . . . . 4-1 memory . . . . . . . . . . . . . . . . . . 2-7 metafile . . . . . . . . . . . . . . . . . . 7-7

O
offset. . . . . . . . . . . . . . . . . . . . 3-6 OSL . . . . . . . . . . . . . . . . . 2-14, 3-2

P
plot overlay . . . . . . . . . . . . . . . . 7-7 power indicator. . . . . . . . . . . . . . 2-23 power meter high accuracy . . . . 1-2, 1-8, 2-22, 6-1 power monitor . . . . 1-2, 1-8, 2-2, 2-16, 5-1 printers . . . . . . . . . . . . . . . . . . 3-14 propagation velocity . . . . . . . . . . . 2-11

Index-1
R
resolution . . . . . . . . . . . . . . . . . 4-8 return loss. . . . . . . . . . . . . . . 4-2, 4-9 RS232. . . . . . . . . . . . . . . . . 2-2, 7-4

S
scale . . . . . . . . . . . . . . . . . . . . 3-8 self test. . . . . . 2-14 - 2-15, 2-18, 2-24, 3-1 serial interface . . . . . . . . . . . . . . . 7-4 Smith Chart . . . . . . . . . . . . . 1-2, 7-10 soft keys . . . . . . . . . . . . . . . . . . 2-8 Software Tools . . . . . . . . . . . . . . 7-1 specifications . . . . . . . . . . . . . . . 1-7 spreadsheet . . . . . . . . . . . . . . . . 7-1 static . . . . . . . . . . . . . . . . . . . 1-11 SWR . . . . . . . . . 2-20, 3-8, 4-2, 4-7, 7-5 symbols. . . . . . . . . . . . . . . . . . 2-17

T
trace overlay . . . . . . . . . . . . . 7-1, 7-7

trigger single sweep . . . . . . . . . . . . . 2-7

U
units . . . . . . . . . . . . . . . . . . . 3-11 USB . . . . . . . . . . . . . . . . . . . . 7-2

V
verification . . . . . . . . . . . . . . . . 1-11

W
windowing . . . . . . . . . . . . . 2-11, A-1 Windows . . . . . . . . . . . . 1-2, 7-1 - 7-2

Index-2
http://www.megaupload.com/?d=EXPSV9VW

Descripcin
El maestro de sitio es un cable de mano y un analizador de antena diseado para instaladores, los contratistas y los proveedores de servicios inalmbricos que necesitan un cable porttil y resistente y analizador de antena. Est diseado para medir la prdida de volver, VSWR, prdida de Cable, de sistemas de cable y antena de 25 MHz a 4 GHz. medicin de distancia a fallas puede utilizarse para buscar la ubicacin exacta de una falla en el sistema de personal. Opciones disponibles con el S331D incluir medidor de corriente de alta precisin (opcin 19) y Monitor de potencia (opcin 5). El sitio maestro es capaz de hasta 1,5 horas de operacin continua de un completamente cargada batera de replaceble de campo y se puede operar desde un origen Vdc 12,5. Conservacin de energa integrada funciones pueden utilizarse para ampliar la duracin de la batera. Un color estndar de 640 * 480 pantalla TFT proporcionan indicaciones grficas de diversas mediciones. La traza mostrada puede escalar o mejorada con lmite y marcadores de frecuencia lneas. Una opcin de men prev un "bip" audible cuando se supera el valor lmite.

1-1

Accesorios estndar
La mano de Software de herramientas y programas de software basado en PC de herramientas de Software de Master proporcionar un registro de base de datos para almacenar los datos de medicin. Herramientas de software tambin pueden convertir Mostrar el sitio maestro para Microsoft Windows_ grfico de la estacin de trabajo de. Mediciones almacenados en el sitio maestro memoria interna puede descargarse al PC mediante la incluye cable serie de mdem nulo. Una vez almacenado, la traza grfica puede mostrar, escala o mejorada con marcadores y lneas de lmite. Grficos histricos pueden se superpone con datos actuales, y base de datos puede extraerse y utilizan en hojas de clculo o para otras tareas analticas. El programa de herramientas de Software de mano puede mostrar mediciones efectuadas con el sitio Master (SWR, prdida de retorno, prdida de cable, distancia a fallas) as como otras funciones, como la conversin de modos de presentacin y grficos de Smith. Consulte el captulo 7, Software de mano Herramientas, para obtener ms informacin. Los siguientes elementos se suministran con el hardware bsico: _ 65717 Maletn blando _ 633-27 Pila recargable Ni-MH _ Adaptador de 40-168-R ACDC _ Adaptador de 12 voltios DC de encendedor automotriz 806-141 _ 2300-347 Herramientas de Software de mano CDROM _ Cable de interfaz serie 800-441 (tipo de mdem nulo) _ 551-1691-R USB para Cable de adaptador de RS-232 _ Gua del usuario del sitio maestro de S331D 10580-00079

_ Garanta

de un ao

Opciones
_ Monitor de potencia de opcin 5 - requiere detector externo _ Opcin 19 alta precisin poder Meter (sensor no incluido)

1-2
Captulo 1 Informacin General

Detectores externos
Los detectores de Anritsu siguientes pueden utilizarse con el S331D de sitio maestro cuando equipado con la opcin 5, Monitor de potencia.
Modelo Frecuencia Gama Prdida de retorno de impedancia Entrada Conn. Respuesta de frecuencia 71N50-5400 0,001 a 3 GHz 50_ 26 dB N(m) _0,2 dB, < 1 GHz _0,3 dB, < 3 GHz 71N75-5400 0,001 a 3 GHz 75_ 26 dB, < 2 GHz 20 dB, < N(m) de 3 GHz _0,2 dB, < 1 GHz _0,5 dB, < 3 GHz 560-7N50B GHz de 0,01 a 20 50_ 15 dB, < 0,04 GHz 22 dB, < 8,00 GHz 17 dB, < 18,0 GHz 14 dB, < 20,0 GHz N(m) _0,5 dB, < 18 GHz _dB 1,25, < 20 GHz 560-7S50B GHz de 0,01 a 20 50_ 15 dB, < 0,04 GHz 22 dB, < 8,00 GHz 17 dB, < 18,0 GHz 14 dB, < 20,0 GHz WSMA (m) _0,5 dB, < 18 GHz _dB 2.0, < 20 GHz 560-7 K 50 GHz de 0,01 a 40 50_ 12 dB, < 0,04 GHz 22 dB, < 8,00 GHz 17 dB, < 18,0 GHz 15 dB, < 26,5 GHz 14 dB, < 32,0 GHz 13 dB, < 40,0 GHz K(m) _0,5 dB, < 18 GHz _dB 1,25, < 26,5 GHz _dB 2.2, < GHz 32 _2,5 dB, < 40 GHz 560-7VA50 0,01 a 50 GHz 50_ 12 dB, < 0,04 GHz 19 dB, < 20,0 GHz 15 dB, < 40,0 GHz 10 dB, < 50,0 GHz V(m) _dB 0,8, < 20 GHz

_2,5 dB, < 40 GHz _3.0 dB, < 50 GHz

1-3
Captulo 1 Informacin General

Accesorios opcionales
Descripcin de nmero de parte Componentes de calibracin Mdulo de calibracin ICN50B InstaCal , MHz 2 GHz 6.0, N(m), 50_ OSLN50-1 precisin abierto/corto/carga, DC 6 GHz, 42 dB, 50_N(m) OSLNF50-1 precisin abierto/corto/carga, DC 6 GHz, 42 dB, 50_N(f) 22N50 Open/corto, DC a 18 GHz, N(m), 50_ Precisin de PL/SM-1 carga, DC a 6 GHz, 42 dB, N(m), 50_ 22NF50 Open/corto, DC a 18 GHz, N(f), 50_ Carga de precisin de SM/PLNF-1, DC a 6 GHz, 42 dB, N(f), 50_ 2000-1618-R precisin abierto/corto/carga, DC 6 GHz, DIN(m) 7/16, 50_ 2000-1619-R precisin abierto/corto/carga, DC 6 GHz, DIN(f) 7/16, 50_ 22N75 Open/corto, DC a 3 GHz, N(m) 75_ 26N75A terminacin de precisin, DC a 3 GHz, N(m) 75_ 22NF75 Open/corto, DC a 3 GHz, N(f) 75_ 26NF75A terminacin de precisin, DC a 3 GHz, N(f) 75_ 12N50-75B coincidencia Pad, DC a 3 GHz, 50 O a 75_ Adaptadores de precisin Adaptador de precisin de 34NN50A, N(m)-N(m), DC a 18 GHz, 50_ Adaptador de precisin de 34NFNF50, N(f)-N(f), DC a 18 GHz, 50_ Adaptadores de Adaptador de 1091-26-R, N(m)-SMA(m), DC a 18 GHz, 50_ Adaptador de 1091-27-R, N(m)-SMA(f), DC a 18 GHz, 50_ Adaptador de 1091-80-R, N(f)-SMA(m), DC a 18 GHz, 50_ Adaptador de 1091-81-R, N(f)-SMA(f), DC a 18 GHz, 50_ Adaptador de 1091-172, N(m)-BNC(f), DC a 1,3 GHz, 50_ Adaptador de 510-90-R, DIN(f)-N(m) 7/16, DC a 7,5 GHz, 50_ Adaptador de 510-91-R, DIN(f)-N(f) 7/16, DC a 7,5 GHz, 50_ Adaptador de 510-92-R, DIN(m)-N(m) 7/16, DC a 7,5 GHz, 50_ Adaptador de 510-93-R, DIN(m)-N(f) 7/16, DC a 7,5 GHz, 50_ 510-96-R adaptador, DIN de 7/16 (m) -7/16 DIN(m), DC a 7,5 GHz, 50_ 510-97-R adaptador, DIN de 7/16 (f) -7/16 DIN(f), DC a 7,5 GHz, 50_ Adaptadores con agarre reforzada Adaptador de 1091-379-R con agarre reforzada, DIN de 7/16 (f) -7/16 DIN(f), DC a 6 GHz, 50_

1-4
Captulo 1 Informacin General
Probar puerto Cables blindados 15NN50-1.5 c prueba puerto Cable blindado, de 1,5 metros, N(m)-N(m), 6 GHz, 50_ 15NN50-3.0 c prueba puerto Cable blindado, 3,0 metros, N(m)-N(m), 6 GHz, 50_ 15NNF50-1.5 c prueba puerto Cable blindado, 1,5 metros, N(m)-N(f), 6 GHz, 50_ 15NNF50-3.0 c prueba puerto Cable blindado, 3,0 metros, N(m)-N(f), 6 GHz, 50_ Probar puerto Cables blindados con agarre reforzada 15RNFN50-1,5-R prueba puerto Cable Armored w/armado agarre 1,5 metros, N(m)-N(f), 6 GHz, 50_ 15RNFN50-3.0-R prueba puerto Cable Armored w/armado agarre 3.0 metros, N(m)-N(f), 6 GHz, 50_ 15RDFN50-1,5-R prueba puerto Cable Armored w/armado agarre 1,5 metros, DIN(f)-N(m) de 7/16, 6 GHz, 50_ 15RDFN50-3.0-R prueba puerto Cable Armored w/armado agarre 3.0 metros, DIN(f)-N(m) de 7/16, 6 GHz, 50_ 15RDMN50-1,5-R prueba puerto Cable Armored w/armado agarre 1,5 metros, DIN(m)-N(m) de 7/16, 6 GHz, 50_ 15RDMN50-3.0-R prueba puerto Cable Armored w/armado agarre 3.0 metros,

DIN(m)-N(m) de 7/16, 6 GHz, 50_ Atenuadores 3-1010-119 Atenuador, 10 dB, 2W, DC 6 GHz 3-1010-122 Atenuador, 20 dB, 5W, DC 12.4 GHz, N(m)-N(f) 42N50-20 atenuador, 20 dB, 5W, DC a 18 GHz, N(m)-N(f) 3-1010-123 Atenuador, 30 dB, 50W, DC GHz 8,5, N(m)-N(f) Atenuador de 42N50A-30, 30 dB, 50W, DC a 18 GHz, N(m)-N(f) 1010-127-R atenuador, 30 dB, 150W, DC a 3 GHz, N(m)-N(f) 3-1010-124 Atenuador, 40 dB, 100W, DC GHz 8,5, N(m)-N(f), Unidireccional 1010-121 Atenuador, 40 dB, 100W, DC a 18 GHz, N(m)-N(f) 1010-128-R atenuador, 40 dB, 150W, DC a 3 GHz, N(m)-N(f) Accesorios diversos Batera recargable de 633-27, Ni-MH Adaptador de 806-141 automotriz encendedor/12 V CC 40-168-R adaptador AC/DC Cargador de batera de 2000-1029, NiMH, con fuente de alimentacin Universal 551-1691-R USB para Cable de adaptador de RS-232 Cable de interfaz serie 800-441 65717 Suave maletn 67135 De sitio maestro de mochila 760-243-R caso de trnsito ODTF-1 mdulo DTF ptico 2300-347 Herramientas de Software de mano CDROM

1-5
Captulo 1 Informacin General
Detectores de Monitor de potencia Detector de 5400-71N50, 001 a 3 GHz, N(m), 50W Detector de 5400-71N75, 75W de 001 a 3 GHz, N(m), Detector de 560-7N50B, 10 MHz a 20 GHz, N(m), 50 W Detector de 560-7S50B, 10 MHz a 20 GHz, WSMA(m), 50 W Detector de 50 de 560-7 K, 10 MHz a 40 GHz, K(m), 50 W Detector de 560-7VA50, 10 MHz a 50 GHz, V(m), 50 W Cables de alimentacin Monitor Extender 800-109 7,6 metros (25 pies) 800-111 30,5 m (100 pies) Alta Accy poder Meter CAC PSN50 Alta precisin poder Sensor, 50 MHz-6 GHz MA24104A Inline alto poder Sensor, 600 MHz a 4 GHz 40-168-R adaptador AC-DC Cable de interfaz serie 800-441 3-1010-122 Atenuador, 20 dB, 5 vatios, DC 12.4 GHz, N(m)-N(f) 1010-127-R atenuador, 30 dB, 150W, DC a 3 GHz, N(m)-N(f) 3-1010-123 Atenuador, 30 dB, 50 vatios, DC GHz 8,5, N(m)-N(f) 3-1010-124 Atenuador, 40 dB, 100W, DC GHz 8,5, N(m)-N(f), Unidireccional 1010-128-R atenuador, 40 dB, 150W, DC a 3 GHz, N(m)-N(f) Documentacin 10580-00100 S33xD programacin Manual (disponible en el disco o en www.US.Anritsu.com) 10580-00101 Manual de mantenimiento de S331D

1-6
Captulo 1 Informacin General

Especificaciones de rendimiento
Especificaciones de rendimiento se proporcionan en la tabla 1-1. Todas las especificaciones aplican al calibrado a temperatura ambiente despus a cinco minutos de calentamiento. Se dan los valores tpicos de referencia, y no estn garantizados.

1-7
Captulo 1 Informacin General Cable y analizador de antena
Rango de frecuencias: 25 MHz a 4000 MHz Precisin de frecuencia: _ _ 50 ppm @ + 25 C Resolucin de frecuencia: 1 kHz (CW en) 100 kHz (CW apagado) Potencia de salida: 0 dBm (tpico) Inmunidad a interferir las seales: +17 en el canal dBm en frecuencia 5 dBm Velocidad de medicin: _ 2,5 ms / punto de datos (CW ON) Nmero de puntos de datos: 130 o 259 o 517 Prdida de devolucin: Gama: 0,00 a 60,00 dB Resolucin: 0,01 dB VSWR: Gama: 1,00 a 65.00 Resolucin: 0,01 Prdida de cable: Gama: 0,00 a 30,00 dB Resolucin: 0,01 dB Precisin de medicin: > 42 dB corregido directividad despus de calibracin Distancia a fallas Intervalo vertical: Prdida de retorno: 0,00 a 60,00 dB VSWR: 1,00 a 65.00 Rango horizontal: 0 (# de datos pts 1) x resolucin hasta un mximo de 1497m (4911 ft) # de datos pts = 130 o 259 o 517 Resolucin horizontal (ventanas rectangulares): Resolucin (metros) = (1,5 x 108) x (Vp) aprovechar Donde Vp es la velocidad de propagacin relativa del cable y DF es la frecuencia de parada menos el iniciar la frecuencia (en Hz). Tabla 1-1. Especificaciones de rendimiento (1 de 3)

1-8
Captulo 1 Informacin General Monitor de potencia (opcin 5, con detector externo)
Rango de medida: dBm de 50 a + 16 dBm (10 nW a 40 mW) Rango de desplazamiento: 0 dB a + 60 dB Intervalo de visualizacin: 80 dBm a 80 dBm Resolucin: 0,1 dB, 0,1 xW Precisin de medicin: 1 dB mximo para > 40 dBm y < 18 GHz con 560-7N50B (consulte curvas de incertidumbre)

Medidor de corriente de alta precisin (opcin 19) Sensores compatibles: PSN50 y MA24104A
PSN50 Alta precisin poder Sensor: Rango de frecuencia: 50 MHz a 6 GHz Rango de medida: 30 dBm a + 20 dBm Sensor de linealidad: 0,13 dB Conector de entrada: tipo N, macho, 50_
Consulte la hoja de datos tcnicos de PSN50, PN: 11410-00423, para especificaciones completas.

MA24104A Inline alto poder Sensor: Rango de frecuencias: 600 MHz a 4 GHz Rango de medida: + 3 dBm a +51.76 dBm (2 mW a 150 W) Sensor de linealidad: 0,13 dB Conector de entrada: tipo N, mujer, 50_ Conector de salida: tipo N, mujer, 50_
Consulte la hoja de datos tcnicos de MA24104A, PN: 11410-00483, para especificaciones completas.

Tabla 1-1. Especificaciones de rendimiento (2 de 3)

1-9
Captulo 1 Informacin General General
Soporte para idiomas: Ingls, espaol, francs, alemn, chino, japons Memoria interna de seguimiento: Hasta 300 trazas Configuraciones de instalacin: 10 Pantalla: Pantalla TFT (640 x 480) de color estndar con control de brillo variable Entradas y salidas de puertos: RF Out: tipo N, mujer, 50_ Entrada mxima sin daos: + 23 dBm, 50 VDC Interfaz serial: RS-232 de 9 pines D-sub, tres cables serial Compatibilidad electromagntica: Cumple los requisitos de la Comunidad Europea para la marca CE Seguridad: Se ajusta a la norma EN 61010-1 para el equipo porttil de clase 1 Temperatura: Funcionamiento:-10 C a 55 C, humedad 85% o menos Inactivo: 51 C a +71 C (almacenar batera por separado entre 0 C y + 40 C para cualquier prolongado perodo de almacenamiento no operativa) Fuente de alimentacin: Entrada DC externo: + 12 a + 15 voltios dc, 3A mximo Internos: Batera de NiMH: 10,8 voltios, 1800 mAh Dimensiones: Tamao (w x h x d): 25,4 cm x 17,8 cm x 6.1 cm (10.0 en x 7.0 en x 2,4 en) Tabla 1-1. Especificaciones de rendimiento (3 de 3)

Mantenimiento preventivo
Mantenimiento preventivo de sitio maestro consiste en limpiar la unidad de inspeccin y limpieza los conectores de RF en el instrumento y todos los accesorios. Limpiar el sitio maestro con un pao suave sin pelusa humedecido con agua o agua y un leve solucin de limpieza. Precaucin: Para evitar daos en la pantalla o el caso, no utilice disolventes o abrasivos limpiadores. Limpiar los conectores de RF y el centro con un hisopo de algodn empapado en alcohol desnaturalizado. Visualmente los conectores. Los dedos de los conectores N (f) y los pines de la Conectores N (m) deben ser continua y uniforme en apariencia. Si no est seguro si los conectores son buenos, medir los conectores para confirmar que las dimensiones son correctas. Visualmente los cables de puerto de prueba. El cable del puerto de prueba debe ser uniforme en apariencia, no se estira, quebrada, abollado o rotos.

Calibracin
El maestro de sitio es una unidad porttil de campo en los rigores del entorno de prueba. Un Calibracin de abierto-corto-carga (OSL), calibracin de InstaCal, FlexCal calibrado con abierto-corto-carga o calibracin de FlexCal con un mdulo de InstaCal debe ser realizado antes para hacer una medicin en el campo (vase calibracin, pgina 3-2). Una temperatura integrada sensor en el sitio maestro informa al usuario cuando la temperatura interna ha superado un ventana de precisin de la medicin y el usuario se aconseja realizar otra calibracin en orden para mantener la integridad de la medida. NOTAS: Para obtener mejores resultados de calibracin: indemnizacin por todas las incertidumbres de medicin: garantizar que el abierto, corto/carga es al final del puerto de prueba o opcional cable de extensin; es decir, en el mismo momento que conectar la antena o dispositivo para ser probado. Para obtener mejores resultados, utilice un puerto de prueba estable de fase (consulte opcional de cables de extensin Accesorios). Si utiliza un cable de productos tpicos de laboratorio para extender la prueba principal de sitio puerto para el dispositivo bajo prueba, cable posterior para la calibracin de OSL

har reflexiones de fase no compensada en el cable. Por lo tanto, los cables que no son fase estable puede provocar errores de medicin que son ms pronuncia medida que aumenta la frecuencia de prueba. Para la calibracin ptima, Anritsu recomienda el uso de calibracin de precisin componentes.

1-10
Captulo 1 Informacin General

Mdulo InstaCal
El mdulo de Anritsu InstaCal puede utilizarse en lugar de componentes discretos para calibrar la Sitio maestro. El mdulo de InstaCal puede utilizarse para realizar un abierto, corto y carga (OSL) o un procedimiento de calibracin de FlexCal. Calibracin del sitio maestro con la toma de InstaCal aproximadamente 45 segundos (consulte calibracin, pgina 3-2). A diferencia de un componente discreto calibrado, el mdulo de InstaCal no puede utilizarse en la parte superior de la torre para realizar la carga o la insercin mediciones de la prdida. Anritsu recomienda verificacin anual del mdulo InstaCal para verificar el rendimiento con datos de instrumento de precisin. La verificacin puede realizarse a un servicio local de Anritsu Centro o en la fbrica de Anritsu.

Verificacin anual
Anritsu recomienda una verificacin anual de calibracin y el rendimiento del sitio maestro y centros de servicio de los componentes de calibracin de OSL y mdulo de InstaCal por Anritsu local. Centros de servicio de Anritsu se enumeran en la tabla 1-2 en la pgina siguiente. El maestro de sitio propio es est autocalibrando, lo que significa que no hay ningn componente campo ajustable. Sin embargo, los componentes de calibracin OSL son cruciales para la integridad de la calibracin y por lo tanto, debe verificarse peridicamente para garantizar la conformidad de rendimiento. Se trata de especialmente importante si los componentes de calibracin OSL han quitado accidentalmente o Over-torqued.

Precauciones ESD
El maestro de sitio, como otros instrumentos de alto rendimiento, es susceptible a dao ESD. Muy a menudo, antenas y cables coaxiales construyen una esttica cobrar, que, si permite cumplir al conectar con el sitio maestro, podra daar los circuitos de entrada del sitio maestro. Sitio Operadores principales deben ser consciente del potencial de dao ESD y tomar todas las necesarias precauciones. Los operadores deben ejercer las prcticas descritas en estndares del sector como JEDEC-625 (EIA-625), MIL-HDBK-263 y MIL-STD-1686, que pertenecen a ESD y ESDS dispositivos, equipos y prcticas. Como estas disposiciones se aplican para el sitio maestro, se recomienda para disipar cualquier esttica que cobra pueden estar presentes antes de conectar los cables coaxiales o antenas para el sitio maestro. Esto puede ser tan simple como asociar temporalmente un corto o dispositivo para el cable o antena de carga antes de conectar con el sitio maestro. Es importante recordar que el operador puede tambin llevar una carga esttica que puede causar daos. Las prcticas describen anteriormente normas asegurar un entorno seguro de personal y equipo.

Centros de servicio de Anritsu


Para localizar el centro de servicio de Anritsu ms cercano, visite: www.Anritsu.com/contact.ASP

Referencias de modo
El trmino "VNA" en referencia al sitio maestro denota modos de analizador de cable y antena.

1-11
Captulo 1 Informacin General

Captulo 2 Funciones y operaciones


Introduccin
Este captulo ofrece una breve descripcin de las funciones de maestro de sitio y operaciones, proporcionando el usuario con un punto de partida para realizar medidas bsicas. Para obtener informacin ms detallada, Consulte los captulos especficos para las mediciones. El sitio maestro est diseado especficamente para entornos sobre el terreno y las aplicaciones que requieren movilidad. Como tal, es una unidad de batera ligera y porttil, operada que puede ser fcilmente a cualquier lugar y es capaz de hasta 1,5 horas de operacin continua de una batera reemplazable campo por tiempo prolongado en el campo. Conservacin de energa integrada caractersticas permiten la batera para ampliarse an ms. El sitio maestro tambin puede ser impulsado por una fuente externa de DC. La fuente externa puede ser tanto el adaptador de AC-DC Anritsu (P/N 40-168-R) o el adaptador de encendedor automotriz (P N 806-141). Ambos elementos son accesorios estndar.

Panel de conectores de prueba


Los conectores y los indicadores que se encuentran en el panel de prueba (figura 2 - 1) se enumeran y describen a continuacin. 12-15VDC (3A) 12 a 15 Vdc @ 3A de entrada a la unidad o para la carga de la batera. ADVERTENCIA Cuando se utiliza el adaptador AC-DC, siempre utilizan un cable de tres hilos conectado a una toma de lnea de alimentacin de tres cables. Si se suministra la alimentacin sin el equipo de toma de tierra de esta manera, se corre el riesgo de recibir una descarga elctrica de grave o mortal, o daar el equipo.

2-1
Figura 2-1. Panel de conectores de prueba

Batera Carga Se enciende cuando la pila est siendo cargada. El indicador se apaga automticamente desactivado cuando la batera est completamente cargada. Externa Poder Se enciende cuando el sitio maestro est siendo impulsado por la unidad de carga externa. Serial Interfaz Interfaz RS232 DB9 a un puerto COM en un ordenador personal (para uso con el Programa de herramientas de Software de mano Anritsu) o a una impresora compatible. Salida RF / Reflexin 50_ Salida RF, 50 _ impedancia de, para la medicin de reflexin. Entrada mxima es + 23 dBm en _50 Vcc. Detector de RF (Opcin 5) Conector de detector de RF para mediciones de Monitor de potencia con una externa detector. Consulte la tabla de detectores de RF disponibles en la pgina 1-3.

2-2
Captulo 2 funciones y operaciones

Visin general de la pantalla


Figura 2-2 ilustra algunas de las reas de informacin clave de la visualizacin de S331D. Captulo 2 funciones y operaciones

2-3
BARRA DE TTULO DATOS PUNTOS BARRIDO TIEMPO CALIBRACIN ESTADO MESSAGEAREA CORRIENTE MEN

Figura 2-2. Visin general de pantalla de S331D

Frontal informacin general del Panel


La interfaz de usuario basada en mens de sitio maestro es fcil de usar y requiere poca capacitacin. Disco duro teclas del panel frontal se utilizan para iniciar funciones especficas mens. Hay cuatro funcin claves duras situado debajo de la ventana de Estado: modo, frecuencia y distancia, amplitud y Botn de medida. Hay diecisiete claves duro de teclado situadas a la derecha de la ventana de Estado. Doce de las claves de teclado duro realizan ms de una funcin, dependiendo del modo actual de operacin. Las claves de doble propsito estn etiquetadas con una funcin de negro, el otro en azul. Tambin hay seis teclas programables que cambian dependiendo de la actual seleccin de modo de funcin. La funcin clave suave actual se indica en el rea de men clave suave a la derecha de la ventana de Estado. Las ubicaciones de las diferentes claves se ilustran en la figura 2-3. Las secciones siguientes describen las distintas funciones claves.

2-4
Captulo 2 funciones y operaciones
Teclas programables Tecla programable Men Teclado numrico Disco duro Claves Duras teclas de funcin
MANTENGA EJECUTAR INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN MARCADOR DE LMITE GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN IMPRIMIR

MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS


ENTRAR CLARO ESCAPE ON OFF

/ 12 4

56
78

90
3
+

S332D

Figura 2-3. Panel frontal de sitio maestro

Duras teclas de funcin


Modo Abre el cuadro de seleccin de modo (abajo). Utilice los arriba/abajo la tecla de flecha para seleccionar un modo de. Prensa el entrar clave para implementar. Nota: Selecciones de modo disponible vara segn el nmero de modelo y Opciones de instalado. Frecuencia/DIST Muestra la frecuencia o la distancia a los mens principales suaves culpa dependiendo de la

modo de medicin (vase la pgina 2-11). Amplitud Muestra el men clave suave de amplitud para el modo de funcionamiento actual (consulte la pgina 2-13). meas/disp Muestra las medicin y mostrar mens claves suaves para la operacin actual modo (vase la pgina 2-14). Captulo 2 funciones y operaciones

2-5
_ Modo de medicin Freq - SWR Volver a prdida Prdida de cable - un puerto DTF - SWR Volver a prdida Monitor de potencia (Detector externo) Medidor de corriente de alta precisin Figura 2-4. Cuadro de seleccin de modo

Teclado duras claves


Esta seccin contiene una lista alfabtica de los controles de teclado del panel frontal de sitio maestro junto con una breve descripcin de cada uno. Ms descripciones detallan de la funcin principal siguen las claves. La siguiente clave de disco duro de teclado funciones se imprimen en negro en el teclado numrico claves. 0-9 Estas claves se utilizan para introducir datos numricos como necesario para la instalacin o realizar mediciones. + / La clave de ms/menos sirve para introducir valores positivos o negativos, segn sea necesario para configurar o realizar mediciones. _ El punto decimal se utiliza para introducir valores decimales segn sea necesario para la instalacin o realizar mediciones. ESCAPE CLARO Se cierra la operacin actual o borra la ventana de Estado. Si un parmetro es se edita, esta tecla se borrar el valor actualmente ser introducido y restaurar la ltima entrada vlida. Esta tecla nuevamente cerrar el parmetro. Durante el barrido normal, esta tecla se mover una nivel de men. Arriba/abajo Flechas Incrementa o reduce el valor de un parmetro. El valor del parmetro especfico afectados normalmente aparece en el rea de mensajes de la pantalla LCD. Entrar Implementa la accin actual o seleccin del parmetro. ON OFF Activa o desactiva la Anritsu sitio maestro. Cuando se activa, el sistema guardado se restaura el estado deen la ltima salida. Si el ESCAPE o borrar la clave se celebra abajo mientras el Encendido/apagado tecla, la fbrica de ajuste preestablecido Estado ser restaurado. SYS Permite seleccin de sistema y parmetros de configuracin de aplicacin y la pantalla idioma.

2-6
Captulo 2 funciones y operaciones La siguiente clave de disco duro de teclado funciones se imprimen en azul en el teclado numrico claves. Esta clave se utiliza para apolvo el brillo de la pantalla. Utilice la flecha arriba/abajo clave y Entrar para ajustar el brillo. Automtico

ESCALA Escala automticamente la ventana de Estado para la resolucin ptima de cable y el modo de analizador de antena. Lmite Muestra el men de lnea de lmite para el modo de funcionamiento actual cuando en cable, analizador de antena. Marcador Muestra el men de marcador del actual modo de funcionamiento en el cable, modo de analizador de antena. Imprimir Imprime la pantalla actual a la impresora seleccionada mediante el puerto serie RS232 RECORDAR VISUALIZACIN Recuerda una traza guardada anteriormente de la memoria. Cuando se presiona la tecla, un Recordar Trace aparece el cuadro de seleccin deen la pantalla. Seleccione un trazado utilizando el Arriba/abajo la tecla de flecha y pulse el Entrar clave para implementar. RECORDAR EL PROGRAMA DE INSTALACIN Recuerda una configuracin guardada anteriormente desde una ubicacin de memoria. Cuando la clave se presiona, un Recordar la configuracin aparece el cuadro de seleccin deen la pantalla. Seleccione un de configuracin utilizando la/pulsada la tecla de flecha y pulse el Entrar clave para implementar. Instalacin 0 recuerda la fbrica ajuste preestablecido de Estado para el modo actual. EJECUTAR MANTENGA En el modo de espera, esta clave inicia el maestro sitio barrer y proporciona un desencadenador de modo de barrido nico; Cuando en el modo de ejecucin, detiene la barrido. En el modo de espera, el smbolo de espera (pgina 2-17) aparece en la pantalla. Mantenga el modo puede utilizarse para ahorrar batera. GUARDAR VISUALIZACIN Guarda hasta 300 huellas mostradas en memoria no voltil. Cuando la clave es presionado, el Seguimiento de nombre: Aparecer el cuadro de. Utilice las teclas para introducir hasta 16 caracteres alfanumricos que rastrear el nombre y pulse el Entrar clave guardar la traza. GUARDAR EL PROGRAMA DE INSTALACIN Guarda la configuracin actual del sistema en una ubicacin de memoria no voltil interna. El nmero de ubicaciones disponibles vara con el nmero de modelo y opciones instaladas. Hay diez localidades disponibles en cable y antena modo de analizador de. Cuando se presiona la tecla, un deGuardar configuracin cuadro de seleccin aparece en la ventana de Estado. Utilice los arriba/abajo la tecla de flecha para seleccionar un el programa de instalacin y pulse el Entrar clave para implementar. INICIO CAL Inicia la calibracin en medida SWR, prdida de volver, prdida de Cable o DTF modos. Captulo 2 funciones y operaciones

2-7

Teclas programables
Cada clave de teclado abre un conjunto de selecciones claves suaves. Cada una de las teclas programables tiene un correspondiente rea de etiquetas clave suaves en la ventana de Estado. La etiqueta identifica la funcin de la tecla programable para la seleccin de modo actual. Las siguientes figuras muestran las etiquetas suaves claves para cada seleccin de modo.

2-8

Captulo 2 funciones y operaciones MODO = prdida de retorno: SOFTKEYS: F1


130 F2 259 517 Parte inferior Seal Estndar
Descendente Arriba abajo enlace Uplink Pgina Arriba Seleccione / Anule la seleccin de Mostrar Seleccionado

Seleccione Trace
Pgina Down

Atrs Atrs
Parte inferior de Lista

Eliminar Trace
Eliminar Todos Trazas

Arriba
Seleccione Estndar Arriba de Lista

Encendido/apagado Resolucin Solo Barrido Trace Math Trace Superposicin Fijo CW

AMPLITUD DE ALTA FRECUENCIA/DIST MEAS/DISP


Pgina Arriba Pgina Down Parte inferior de Lista Arriba de Lista

Figura 2-5. Prdida modo suave clave etiquetas

Captulo 2 funciones y operaciones

2-9
MODO = DTF: TECLAS PROGRAMABLES:
Parte inferior Arriba

AMPLITUD FREQ/DIST
D2 DTF ayuda Ms D1 Prdida Cable

Ventana

Atrs Prop Vel Re pg Seleccione Trace Pgina Down Atrs


Parte inferior de Lista

Eliminar Trace
Eliminar Todos Trazas Arriba de Lista

Encendido/apagado Resolucin Solo Barrido Trace Math Trace Superposicin Fijo CW

MEAS/DISP
Figura 2-6. Distancia a las fallas modo suave etiquetas

2-10
Captulo 2 funciones y operaciones
Sistema Opciones Hora
Aplicacin Opciones

Reloj Estado Minuto Self Prueba Mes Idioma


Ingls

Da Ao Unidades GPS Encendido/apagado Impresora CAL Modo


Cambio Fecha Formato

Atrs Atrs Copia de ubicacin Calidad Restablecer Atrs GPS

Figura 2-8. SYS tecla men en Cable y modo de analizador de antena


SOFTKEYS: Centro
Seal Estndar

Offset dB Cero Rel

AMPLITUD FREQ/DIST
Max Mantenga Lmite ENCENDIDO/APAGADO Inferior Lmite Superior Lmite Lmite Unidades En ejecucin

Promedios

MEAS/DISP
Descendente Uplink Pgina Arriba Seleccione / Anule la seleccin de Mostrar Seleccionado Pgina Down

Atrs
Parte inferior de Lista Seleccione Estndar Arriba de Lista Seleccione Canal

Figura 2-7. Teclas de modo (opcin 19) de Sensor suave de poder de alta precisin

Frecuencia/DIST Muestra la frecuencia y la distancia men segn el modo de medicin. Frecuencia Men El men a distancia y la frecuencia de las mediciones de analizador de cable y antena proporciona para establecer puntos de finales de frecuencia de barrido cuando Freq se selecciona el modo de. Seleccionado valores de frecuencia pueden cambiarse mediante el teclado o arriba/flecha abajo clave. F1 : Se abre el parmetro de F1 para entrada de datos. Este es el valor de inicio para el barrido de frecuencia de. Prensa entrar cuando la entrada de datos es completa. F2 : Se abre el parmetro F2 para entrada de datos. Este es el valor de parada para los barrido de frecuencia de. Prensa entrar cuando la entrada de datos es completa. Seal estndar : Permite la seleccin del nivel de seal que se utiliza. Seleccione de las normas internacionales disponibles (apndice C). Distancia Men Proporciona para establecer la distancia a parmetros de errores cuando se selecciona un modo DTF. Elegir DIST causas soft teclas, a continuacin, mostrar y el correspondiente valores que se muestra en el rea de mensajes. Valores de distancia seleccionado pueden ser cambiar mediante el teclado o arriba/abajo. D1 : Se abre el parmetro de distancia (D1) de inicio para entrada de datos. ste es el comienzo valor depara el rango de distancia (D1 predeterminado = 0). Prensa entrar cuando la entrada de datos es completa. D2 : Se abre el parmetro de distancia (D2) final para entrada de datos. Este es el fin valor depara el rango de distancia. Prensa entrar cuando la entrada de datos es completa. DTF ayuda Proporciona ayuda interactiva para optimizar la DTF configurar parmetros. Uso clave dela flecha arriba o abajo para seleccionar un parmetro a editar. Prensa entrar cuando entrada de datos es completa. Ms : Selecciona el submen de distancia, detalladas a continuacin. Prdida : Se abre el parmetro de prdida de Cable de entrada de datos. Introduzca la prdida por Medidor (o pie) para el tipo de lnea de transmisin que se est probando. Prensa Entrar cuando finalice la entrada de datos. (Gama es 0,5 a 5.0 dB/m, 1.524 dB/ft) Apuntalar Vel (velocidad de propagacin relativa), abre la velocidad de propagacin parmetro de entrada de datos. Escriba la velocidad de propagacin del tipo de lnea de transmisin deque se est probada. Prensa entrar cuando la entrada de datos es completa. (Gama es 0,010 a 1.000) Cable Abre una lista de carpetas coaxial comn de cable tres (1000 MHz, MHz de 2000 y 2500 MHz) y una carpeta personalizada. Seleccione una carpeta y use las/pulsada la tecla de flecha y Entrar para realizar una seleccin. Esto funcin proporciona un medio rpido de prdida de cable y propagacin velocidad. (Consulte el Apndice A para obtener una lista de los cables coaxiales comunes Mostrar valores de velocidad relativa de propagacin y atenuacin Nominal

en dB/m o dB/ft @ 1000 MHz, MHz 2000 y 2500 MHz). La costumbre carpeta de cable puede constar de hasta 49 parmetros de cable definidos por el usuario cargado a travs del programa de herramientas de Software de computadora de mano. Ventana : Se abre un men de tipos de ventanas FFT para el clculo de DTF. Desplcese en el men utilizando la/pulsada la tecla de flecha y realice una seleccin con la Entrar clave de. Consulte Apndice B para obtener ms informacin sobre ventanas. Volver Devuelve el men distancia. Captulo 2 funciones y operaciones

2-11
Marcador Elegir Marcador en cable y alta frecuencia de analizador de antena y dist modo causa el soft teclas, a continuacin, se muestra y los valores correspondientes para mostrar en el rea de mensajes. Marcador de frecuencia seleccionada o ubicaciones de marcador de distancia puede cambiarse mediante el teclado o arriba/abajo la tecla de flecha. M1 : Selecciona el parmetro de marcador M1 y abre el marcador M1 segundo men de nivel. Encendido/apagado : Activa el marcador seleccionado en o apagado Editar : Se abre el parmetro de marcador seleccionado para entrada de datos. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar el anterior valor. Marcador de pico : Coloca el marcador seleccionado en la frecuencia o la distancia con el valor de amplitud mxima. Marcador al valle : Coloca el marcador seleccionado en la frecuencia o la distancia con el valor de amplitud mnimo. Volver Devuelve el men de marcadores principal. M2 a travs de M4 : Selecciona el parmetro de marcador y abre el marcador segundo men de nivel. Encendido/apagado : Activa el marcador seleccionado en o apagado Editar : Se abre el parmetro de marcador seleccionado para entrada de datos. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar el anterior valor. Delta (Mx-M1) Muestra el valor de amplitud de delta, as como la frecuencia de delta o distancia para el marcador seleccionado en el marcador de la M1. Marcador de pico : Coloca el marcador seleccionado en la frecuencia o la distancia con el valor de amplitud mxima. Marcador al valle : Coloca el marcador seleccionado en la frecuencia o la distancia con el valor de amplitud mnimo. Volver Devuelve el men de marcadores principal. Todos desactivados Convierte todos los marcadores apagado Ms : Abre la continuacin de los mens de marcador. M5 : Selecciona el parmetro de marcador M5 y abre el segundo nivel de M5 men. Encendido/apagado : Activa el marcador seleccionado en o apagado Editar : Se abre el parmetro de marcador seleccionado para entrada de datos. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar el anterior valor. Pico entre M1 y M2 : Coloca el marcador seleccionado en la frecuencia o distancia con el valor de amplitud mxima entre marcador M1 y M2 de marcador. Valle entre M1 y M2 : Coloca el marcador seleccionado en la frecuencia o distancia con el valor de amplitud mnimo entre marcador M1 y M2 de marcador. Volver Devuelve el men de marcadores principal.

2-12
Captulo 2 funciones y operaciones M6 : Selecciona el parmetro de marcador de M6 y abre el segundo nivel de M6

men.
Encendido/apagado : Activa el marcador seleccionado en o apagado Editar : Se abre el parmetro de marcador seleccionado para entrada de

datos. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar el anterior valor. Pico entre M3 y M4 : Coloca el marcador seleccionado en el pico entre M3 marcadores y M4. Valle entre M3 y M4 : Coloca el marcador seleccionado en el Valle de entre M3 marcadores y M4. Volver Devuelve el men de marcadores principal. Todos desactivados Desactiva todos los marcadores Volver Devuelve el men de marcadores principal. Lmite Pulsar Lmite en el cable y la frecuencia de analizador de antena y el modo de distancia activa un men de lmite de funciones relacionadas. Utilice la tecla programable correspondiente para seleccionar la funcin de lmite deseado. A continuacin, use las/pulsada la tecla de flecha para cambiar su valor, que se muestra en el rea de mensajes en la parte inferior de la ventana de Estado. Elegir Lmite en Freq o DTF modos de medicin hace las siguientes de teclas programables para mostrarse. Lmite nico Establece un valor lmite nico de dBm. Las opciones del men son: Encendido/apagado : Activa o desactiva la funcin de lmite nico Editar : Permite la entrada de la amplitud de lmite. Volver Devuelve el men anterior. Lmites mltiples : Conjuntos definidos por el usuario mltiples limita y puede utilizarse para crear una mscara de lmite para las mediciones de pasa/no pasa rpido. Segmento 1 al segmento 5 : Abre el men de segmento. Encendido/apagado : Activa el segmento o apagado Editar : Se abre el parmetro de entrada de datos. Segmento anterior , Editar o ver los parmetros del segmento anterior. Siguiente segmento , Editar o ver los parmetros del siguiente segmento. Si el siguiente segmento est desactivado cuando se presiona este botn, el punto de partida del siguiente segmento se establecer igual hasta el punto final de la actual segmento. Volver Devuelve el men anterior. Volver Devuelve el men anterior. Limitar el sonido : Activa el indicador de sonido audible lmite en o apagado Captulo 2 funciones y operaciones

2-13
SYS En el analizador de cable y antena o modo de contador de alimentacin opcional, apremiantes la SYS clave muestra las siguientes sistema suaves claves selecciones de men: Opciones de sistema : Muestra un segundo nivel de funciones de opcin de sistema: Reloj : Muestra un segundo nivel de funciones: Hora : Introduzca la hora (0-23) mediante la/pulsada la tecla de flecha o la teclado. Prensa entrar cuando la entrada de datos es completa o escapar a restaurar el valor anterior. Minuto : Escriba el minuto (0-59), utilizando la/pulsada la tecla de flecha o el teclado. Prensa entrar cuando la entrada de datos es completa o escapar para restaurar el valor anterior. Mes : Escriba el mes (1-12) utilizando la/pulsada la tecla de flecha o la teclado. Prensa entrar cuando la entrada de datos es completa o escapar a restaurar el valor anterior. Da : Escriba el da usando la/pulsada la tecla de flecha o el teclado. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar la valor anterior. Ao : Escriba el ao (2003-2036) mediante la/pulsada la tecla de flecha o el teclado. Prensa entrar cuando la entrada de datos es completa o escapar

para restaurar el valor anterior. Volver Devuelve el nivel superior men SYS. Impresora : Muestra un men de impresoras compatibles. Utilice los arriba/flecha abajo clave y Entrar clave para hacer la seleccin. Unidades : Seleccione la unidad de medida (mtrico o ingls). Cambiar el formato de fecha : Activa o desactiva el formato de fecha entre DD/MM/AAAA, DD/MM/AAAA y AAAA/MM/DD. Volver Devuelve el nivel superior men SYS. Opciones de aplicacin : Opciones de aplicacin muestra opciones aplicables a determinados modo. Modo de CAL : En los modos de analizador de cable y antena, selecciona cualquiera OSL Cal o FlexCal_. FlexCal es una calibracin de frecuencia de banda ancha vlida de 25 MHz 4 GHz (2 MHz a 6 GHz con opciones 2 y 16). Consulte calibracin, pgina 3-2, para obtener ms informacin. Volver Devuelve el nivel superior men SYS. Auto prueba : Inicia un instrumento prueba. auto Estado En cable y antena analizador freq o dist modo de medicin, muestra el estado actual del instrumento, incluida situacin de calibracin, temperatura, y estado de carga de batera. Prensa escapar para volver a la operacin. Idioma : Presionar esta tecla programable inmediatamente cambia el idioma utilizado para Mostrar mensajes en la ventana de estado de sitio maestro. Las opciones son ingls, Francs, alemn, espaol, chino y japons. Es el idioma predeterminado Ingls. El modo en el Monitor de potencia, urgente la SYS clave muestra el siguiente sistema selecciones clave de suave de men: Opciones de sistema : Muestra un segundo nivel de funciones de opcin de sistema: Reloj : Muestra un segundo nivel de funciones: Hora : Introduzca la hora (0-23) mediante la/pulsada la tecla de flecha o la teclado. Prensa entrar cuando la entrada de datos es completa o escapar a restaurar el valor anterior.

2-14
Captulo 2 funciones y operaciones Minuto : Escriba el minuto (0-59), utilizando la/pulsada la tecla de flecha o el teclado. Prensa entrar cuando la entrada de datos es completa o escapar para restaurar el valor anterior. Mes : Escriba el mes (1-12) utilizando la/pulsada la tecla de flecha o la teclado. Prensa entrar cuando la entrada de datos es completa o escapar a restaurar el valor anterior. Da : Escriba el da usando la/pulsada la tecla de flecha o el teclado. Prensa Entrar cuando la entrada de datos es completa o ESCAPE para restaurar la valor anterior. Ao : Escriba el ao (2003-2036) mediante la/pulsada la tecla de flecha o el teclado. Prensa entrar cuando la entrada de datos es completa o escapar para restaurar el valor anterior. Volver Devuelve el nivel superior men SYS. Impresora : Muestra un men de impresoras compatibles. Utilice los arriba/flecha abajo clave y Entrar clave para hacer la seleccin. Unidades : Seleccione la unidad de medida (mtrico o ingls). Cambiar el formato de fecha : Activa o desactiva el formato de fecha entre DD/MM/AAAA, DD/MM/AAAA y AAAA/MM/DD. Volver Devuelve el nivel superior men SYS. Auto prueba : Inicia un instrumento prueba. auto Estado En cable y antena analizador freq o dist modo de medicin, muestra el estado actual del instrumento, incluida situacin de calibracin, temperatura, y estado de carga de batera. Prensa escapar para volver a la operacin.

Idioma

: Presionar esta tecla programable inmediatamente cambia el idioma utilizado para Mostrar mensajes en la ventana de estado de sitio maestro. Las opciones son ingls, Francs, alemn, espaol, chino y japons. Es el idioma predeterminado Ingls. Captulo 2 funciones y operaciones

2-15

Monitor de potencia, Detector externo (opcin 5)


Seleccionar Monitor de potencia (Detector externo) en el men modo provoca las teclas programables, descritas a continuacin, para mostrarse y los valores correspondientes se muestran en el rea de mensajes. Unidades : Cambia entre dBm y W. Rel : Activa el modo relativo, si actualmente ON. Si el modo relativo es actualmente DESACTIVADO, lo convierte y hace que el nivel de potencia medida y guardar como el nivel de base. Se muestran las siguientes medidas respecto a esto valor guardado. Con unidades de dBm, modo relativo muestra dBr; con unidades de Watts, modo relativo muestra % (por ciento). Desplazamiento de dB Convierte Offset OFF, si actualmente ON. Si el desplazamiento est desactivado, convierte y abre el parmetro Offset para entrada de datos (0-60). Prensa Entrar cuando la entrada de datos es completa. Desplazamiento es la atenuacin (en dB) insertada en la lnea entre la DUT y la Detector de RF. La atenuacin se agrega al medida antes de nivel entrado para mostrar. Cero Se vuelve cero fuera, si actualmente ON. Si cero actualmente est desactivado, esta suave clave lo convierte e inicia la coleccin de una serie de muestras de nivel de potencia, promedi y guardados. Esto guarda valor, a continuacin, se resta del posterior antes de mediciones para mostrar.

2-16
Captulo 2 funciones y operaciones

Smbolos
Tabla 2-1 proporciona una lista de los smbolos utilizados como indicadores de condicin en el estado de LCD ventana. Captulo 2 funciones y operaciones

2-17
Smbolo de icono Sitio maestro est en suspenso para la conservacin de energa. Para reanudar el barrido, pulse el Ejecutar/bloqueo clave de. Cuando se ejecuta en batera, despus de 10 minutos Sin una pulsacin de tecla, el maestro de sitio se activar automticamente el poder modo de conservacin. Falta de integracin. Fallo intermitente integrador puede ser causada por interferencias de otra antena. Fracaso persistente integrador indica una necesidad para devolver el sitio maestro para el centro de servicio de Anritsu ms cercano para su reparacin. Bloqueo no indicacin. Compruebe la pila. (Si el sitio maestro no bloquear con una batera totalmente cargada, llame el centro de servicio de Anritsu). Cuando se realiza la calibracin, el sitio maestro almacena la temperatura. Si la temperatura se aleje fuera del rango especificado, este icono aparecer en la parte superior de la ventana de Estado y el Cal fuera se muestra un mensaje. Se recomienda una reevaluacin a la temperatura actual. Indica la carga restante en la batera. El rectngulo blanco interior crece ms que reduce la carga de la batera. Indica el procesamiento de datos interno. El sitio maestro ha sido calibrado con abrir discreto, corto y carga

componentes. El maestro del sitio ha sido calibrado con el mdulo InstaCal. No se ha calibrado el sitio maestro. El sitio maestro ha sido calibrado con abrir discreto, corto y carga componentes de la frecuencia apoyo de la dependencia. El maestro del sitio ha sido calibrado con el mdulo InstaCal para la frecuencia el apoyo de la unidad. Tabla 2-1. Smbolos de icono de LCD
MANTENGA

DX T

Cal en Cal en! Cal fuera FlexCal en FlexCal en!

Autocomprobacin
En provocativo, el maestro de sitio se ejecuta a travs de una serie de pruebas rpidas para asegurar que el sistema est funciona correctamente. Tenga en cuenta que la tensin y la temperatura se muestran en la parte inferior izquierda esquina debajo el mensaje de prueba automtica. Si la batera est baja, o si la temperatura ambiente no es dentro del rango especificado operacional, comprobacin automtica fallar. Si se produce un error en la comprobacin automtica y la batera completamente cargada y el maestro de sitio est dentro del rango de temperatura funcionamiento especificado, llamada el centro de servicio de Anritsu desde: http://www.Anritsu.com/contact.ASP

2-18
Captulo 2 funciones y operaciones

Mensajes de error
Mensajes de Error de prueba automtica
Una lista de mensajes de Error de prueba automtica se proporciona en el cuadro 2-2. Captulo 2 funciones y operaciones

2-19
Descripcin del mensaje de error

Batera baja Voltaje de la batera dees inferior a 9,5 voltios. Cargar la batera. Si el problema persiste, Llame a su centro de servicio de Anritsu. Baja de alimentacin externa Tensin de alimentacin externa es inferior a 10 voltios. Llamar al servicio de Anritsu Centro Error de PLL No se ha podido bloquearfase bucles. Cargar la batera. Si el problema persiste con una batera completamente cargada, llame a su centro de servicio de Anritsu Integrador de error Circuito de integracinno puede cobrar a un nivel vlido. Cargar pilas. Si el problema persiste con una batera completamente cargada, llame a su Anritsu Centro de servicio. EEPROM R/W No se pudo Ha fallado el sistema de memoria no voltil. Llamar al servicio de Anritsu Centro.

De Temp. Gama Temperatura ambiente no dentro de lo especificado est funcionando gama. Si la temperatura est dentro del intervalo especificado de funcionamiento y la condicin persiste, llame a su centro de servicio de Anritsu. RTC batera baja La batera interna reloj en tiempo real es baja. Una batera de reloj bajo o drenaje afectar el sello de fecha guardada huellas. Contacto su ms cercano Centro de servicio de Anritsu. Batera Cal perdido Error de comunicacinbatera. El estado de carga de batera indicado puede ser vlido. Si el problema persiste, llame a su centro de servicio de Anritsu. Error de memoria EEPROM la prueba en el tablero principal de sitio maestro ha fallado. Si condicin persiste, llame a su centro de servicio de Anritsu. La fecha y hora No ha sido definido en este sitio maestro. Para configurarlo, despus de salir Pulse aqu la <SYS> [reloj] claves. Pulse Intro o ESC para continuar La fecha y no se establecen en el sitio maestro. Si condicin persiste, llame a su centro de servicio de Anritsu.
Nota: Pgina 1-11 proporciona informacin de contacto para Anritsu servicio centros.

Tabla 2-2. Self mensajes de Error de prueba

Mensajes de Error de gama


Una lista de mensajes de Error de gama se proporciona en la tabla 2-3.

2-20
Captulo 2 funciones y operaciones
Descripcin del mensaje de error

GAMA ERROR: F1 > F2 La frecuencia de inicio (F1) es mayor que la frecuencia de parada (F2). GAMA ERROR: D1 > D2 La distancia inicial (D1) es mayor que la distancia de parada (D2). GAMA ERROR: D2 > DMax=xx.x m (m) La distancia de parada (D2) supera el rango mximo de unaliased. Esto gama est determinado por el intervalo de frecuencia, el nmero de puntos, y la velocidad de propagacin relativa: Gama de MaximumUnaliased DP v f FF (1.5 108) ( 1) ( ) 21 En: DP es el nmero de puntos de datos (130, 259 o 517) Vf es la velocidad de propagacin relativa F2 es la frecuencia de parada en Hz F1 es la frecuencia de inicio en Hz Rango mximo de Unaliased es en metros

RANGO DE ERROR: Parte superior < = inferior El valor superior del parmetro escala SWR es menor o igual a su parte inferior valor. RANGO DE ERROR: Inicio > = inferior El valor superior del parmetro escala RL es mayor o igual a su parte inferior valor. Tabla 2-3. Mensajes de Error de gama

Mensajes de Error de InstaCal


Si el nmero de serie del mdulo InstaCal conectado no coincide con el nmero de serie almacenados en el sitio principal, se muestra el siguiente mensaje: Los datos de caracterizacin de InstaCal almacenados en el sitio principal es un mdulo diferente del actualmente conectado. Sitio principal contiene datos para InstaCal mdulo S/n: xxxxx Actualmente conectado InstaCal mdulo S/n: xxxxx Desea sobrescribir la caracterizacin previamente cargada de InstaCal? Prensa el S tecla programable para actualizar la caracterizacin InstaCal almacenada para utilizar la actualmente mdulo conectado. Prensa el N tecla programable para mantener la caracterizacin InstaCal almacenados. Una lista de posibles mensajes de error de InstaCal se proporciona en la tabla 2-4. Captulo 2 funciones y operaciones

2-21
Descripcin del mensaje de error

Error al leer el serial nmero de InstaCal mdulo


El maestro del sitio no pudo leer el nmero de serie del mdulo de InstaCal.

No pudo con xito transferencia mdulo instacal datos para el sitio maestro
El sitio maestro pudo transferir todos los datos necesarios entre el Mdulo de InstaCal y el sitio maestro.

No se pudo establecer la velocidad en baudios con InstaCal mdulo


El maestro del sitio no pudo establecer comunicacin con el Mdulo de InstaCal. Tabla 2-4. Mensajes de Error de InstaCal

Mensajes de Error alta precisin poder Meter (opcin 19)


Los siguientes mensajes de error pueden mostrarse en el sitio maestro cuando se utiliza la alta Modo de medidor de corriente de precisin con poder Sensor PSN50. Si cualquier condicin de error persiste, Pngase en contacto con su centro de servicio de Anritsu local.

Mensajes de Error general


A continuacin se proporciona una lista de mensajes de Error General.

2-22
Captulo 2 funciones y operaciones
Descripcin del mensaje de error

Advertencia! Poder Error de suministro


Compruebe que el suministro est conectado correctamente.

Advertencia! Potencia de RF Nivel es demasiado alto

El rango de medicin superior especificado es de + 20 dBm. No superen la especificacin.

Advertencia! Sensor no cero correctamente. Sensor de cero otra vez


El sensor debe ser cero con nada conectados a l. Advertencia! Especificado rango de temperatura (0 a 50_C) super Rango de temperatura de PSN50 el sensor es de 0 a 50_C. Advertencia! Temperatura ha cambiado. Sensor de cero otra vez Ms que el lmite permitido cambi el sensor de la temperatura fue puesto a cero. Tabla 2-5. Mensajes de Error de opcin 19 Mensaje de error Descripcin

CAL Incompleta Un completo abierto, corto y calibracin de carga deben realizarse antes de calibracin puede ser activado. Dist requiere F1 < F2 Distancia vlido a parcelas de culpa requieren un perodo de frecuencia cero. Datos no vlidos de barrido Los datos de barrido estn vlido. Men de opciones de uso para seleccionar una impresora Intenta imprimir una pantalla con ninguna impresora seleccionada. Seleccione una impresora, vuelva a intentar. FlexCal no es adecuada para este caso, Cambiar A OSL Modo de CAL (SYS-opciones) El cable es demasiado largo o demasiado reflexivo para FlexCal a trabajar. Cal OSL debe utilizarse en su lugar. No cero seal de entrada demasiado alta Intentar realizar un medidor de energa cero funcin de ajuste con una entrada de ms de 20 dBm.
Tabla 2-6. Mensajes de Error general

Informacin de batera
Carga de una batera nueva
La batera de NiMH suministrada con el sitio maestro ya ha completado tres de carga y ciclos de aprobacin de la gestin en la fbrica y el rendimiento de la batera completa deben realizarse despus de su primera carga. Nota: Uso nico Anritsu haba aprobado bateras, adaptadores y cargadores con este instrumento. La batera no cobrar si la temperatura de la batera est por encima de 45_ C o por debajo de 0_ C.

Carga de la batera en el sitio principal


La batera puede cargarse si bien instalado en el sitio maestro. Paso 1. Gire a la Oficina principal de sitio Paso 2. Conecte el adaptador AC-DC (nmero de pieza de Anritsu: 40-168-R) para el sitio maestro Puerto de carga. Paso 3. Conectar el AC adaptador a un 120 VCA o fuente de alimentacin de 240 VAC segn corresponda

para su aplicacin. Se iluminar el indicador de alimentacin externa verde en el sitio maestro, que indica la presencia de la corriente externa, se enciende el indicador de carga de la batera, y la batera comenzar la carga rpida. Si la batera no se carga, pngase en contacto con su Centro de servicio de Anritsu ms cercano. Notas: si la temperatura de la batera es superior a 50_ C durante la carga, la carga parada y el indicador de carga se apagar. La carga se reanudar automticamente cuando la temperatura desciende por debajo de 50_ C.

Carga de la pila en el cargador opcional


Pueden cargar hasta dos bateras secuencialmente en el cargador de batera. Paso 1. Extraiga la batera de NiMH de tu sitio maestro y colocarlo en el opcional cargador (nmero de pieza de Anritsu 2000-1029). Paso 2. Conectar el plomo desde el adaptador AC-DC para el cargador. Paso 3. Adaptador de conexin AC-DC un 120 VCA o fuente de alimentacin de 240 VAC segn corresponda para su aplicacin. Cada titular de batera en el cargador opcional tiene un indicador LED de estado de carga. El LED color cambia a medida que la batera est cargada: Rojo indica que la batera se est cargando Verde indica que la batera est completamente cargada Amarillo indica que la batera est en un Estado de espera (vase ms abajo). Una luz amarilla puede deberse a que la batera se convirti en demasiado caliente durante el ciclo de carga. El cargador permitir la batera para refrescarse antes de continuar en el cargo. Una luz amarilla Tambin puede indicar que el cargador es alternando gratuitamente a cada una de las dos bateras. Captulo 2 funciones y operaciones

2-23
Una luz roja parpadeante indica que VDC menos de 13 se suministra al stand de cargador. Compruebe que est conectado el adaptador de cargador de CA correcto al stand de cargador. Si la batera no cargar, pngase en contacto con su centro de servicio de Anritsu ms cercano.

Determinar la duracin de la batera restante


Cuando el adaptador AC-DC est desconectado desde el sitio maestro, el smbolo de indicador de batera continuamente aparecer en la esquina superior izquierda de la pantalla del sitio maestro (figura 2-7). Una barra negra totalmente en el icono de batera indica una batera totalmente cargada. Cuando baja BATT reemplaza la barra de indicador de batera en la esquina superior izquierda, un par de minutos de medicin restos de tiempo. Si un parpadeo BATT bajo es acompaado por un tono de sonido audible en el final de cada traza, la batera tiene aproximadamente un minuto de tiempo utilizable restante. Una vez que haya filtrado toda la potencia de la batera, la pantalla LCD del sitio maestro se desvanecern. En este punto, su maestro de sitio apagar por s mismo y la batera deber ser recargado. Durante la operacin, el estado de la batera puede verse pulsando el SYS clave y seleccionar el Auto prueba tecla programable de(figura 2-8). El estado de la batera se mostrar como un porcentaje de carga restante.

2-24
Captulo 2 funciones y operaciones

INDICADOR DE BATERA
Todos Off Ms

Figura 2-7. Indicador de batera de sitio maestro Selftest Temperatura............ 24_C Memory . . . . . . . . . . . . . . . . PASADO Batera RTC............. 3.1V Voltage . . . . . . . . . . . . . . . . Batera (11.1V) Batera Cal.............. PASADO Carga de la batera........... 84% (Me = 743mA)

VNA PLL . . . . . . . . . . . . . . . PASADO Integrador VNA.......... PASADO Prensa ESCAPE al regreso. Figura 2-8. Pantalla de prueba automtica

Duracin de la batera
La batera de NiMH va durar ms y funcionan mejor si permite cumplir completamente antes de recargar. Para el mximo de la batera, se recomienda que la batera de NiMH completamente descargada y recargada cada tres meses. El circuito de carga en el sitio maestro est diseado para optimizar la vida de la batera. Si la temperatura en el interior el instrumento sea superior a 50 _C, se suspender el actual ciclo de carga y un nuevo ciclo de carga no se iniciar hasta que la temperatura ha llegado a 50_C. El sitio maestro tambin est equipado con un proceso de carga automtico que cambia el carga de nivel basado en la capacidad de la batera. Si la batera ha sido completamente descargada a cero voltios, se aplicar un pre-charge en un DC bajo actual hasta que la batera alcanza un nivel que es seguro para un ciclo de carga ms rpido. Del mismo modo, la carga de nivel cambiar cuando la batera est cercana a totalmente cargada. Este proceso de carga ayuda a maximizar el nmero de ciclos de recarga disponibles de la batera. Es normal que las bateras NiMH a self-discharge durante el almacenamiento (figura 2-9) y a degradar a 80% de la capacidad original despus de 12 meses de uso continuo. La batera se puede cargar y Descargar 300 a 500 veces, pero finalmente se gastar. La batera puede que deba ser sustituido cuando el tiempo de funcionamiento entre carga es notablemente ms corto de lo normal. Captulo 2 funciones y operaciones

2-25
Figura 2-9. Caractersticas de almacenamiento de batera de NiMH

Informacin importante sobre las pilas


_ Batera

de NiMH el suministrado con el sitio maestro ya ha completado tres cargos y ciclos de aprobacin de la gestin en la fbrica y el rendimiento de la batera completa deben realizarse despus de la primera carga. _ Recarga la batera slo en el sitio principal, o en un Anritsu aprobado cargador. _ Si se deja sin usar, una batera completamente cargada descargar s ms tiempo. _ Almacenar la batera en lugares calientes o fros extremos reducir la capacidad y la duracin de la batera. La batera se descargar ms rpido a altas temperaturas ambientales (vase la figura 2-9). _ Una batera de NiMH de vez en cuando para mejorar el rendimiento de la batera y la batera de descarga vida. _ La batera se puede cargar y Descargar cientos de veces, pero finalmente llevarn a. _ La batera puede que deba ser sustituido cuando el tiempo de funcionamiento entre carga es notablemente ms corto de lo normal. _ Si se permite una batera totalmente cumplir, la capacidad de memoria inteligente de la batera se puede perder, lecturas de capacidad de la batera incorrecta o prdida de comunicacin con la batera. _ No tocaran los terminales de la batera. _ No coloque, mutilar o intentar desmontar la batera. _ Nunca utilice un cargador daado o desgastada o batera. _ Utilizar siempre la batera para su finalidad slo. _ Temperaturas extremas afectar la capacidad de carga de la batera. Deje la batera enfriar o caliente como necesarias antes de usar o carga. _ Almacenamiento de la batera se recomienda en menos de 45 _ C. _ Bateras dedeben ser recicladas o eliminadas correctamente. No coloque las bateras en la papelera. _ No deseche las bateras en un incendio!

2-26
Captulo 2 funciones y operaciones

Captulo 3 Introduccin
Introduccin
Este captulo ofrece una breve descripcin de Anritsu sitio maestro. La intencin de este captulo es proporcionar al usuario un punto de partida para cable bsico y analizador de antena mediciones.

Encendido de procedimiento
El maestro de sitio Anritsu es capaz de hasta 1,5 horas de operacin continua de un completo batera cargada, reemplazable. Funciones de conservacin de energa incorporada permiten a la batera ampliarse. El maestro de sitio tambin puede ser operado de una fuente externa de DC (que ser tambin simultneamente cargar la batera). Esto puede lograrse con el adaptador de AC-DC de Anritsu (P/N 40-168-R) o el adaptador de encendedor automotriz (P N 806-141). Ambos elementos son incluido como accesorios estndar (consulte el captulo 1). Al poder en el sitio maestro: Paso 1. Prensa el Encendido/apagado clave del panel frontal (figura 3 - 1). Paso 2. El sitio maestro mostrar el nmero de modelo, la revisin de firmware interno temperatura y voltaje y, a continuacin, realizar un segundo cinco autoprueba. Al finalizar de la prueba automtica, la pantalla muestra una solicitud para la prensa Entrar a continuar. Si introduce no est presionado, el sitio maestro continuar despus de un segundo cinco tiempo de espera. Paso 3. Prensa Entrar continuar. El maestro de sitio est preparado para la operacin.

3-1
ENCENDIDO/APAGADO CLAVE
MANTENGA EJECUTAR

INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN Lmite Marcador
GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN

IMPRIMIR

MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS


ENTRAR CLARO ESCAPE ON OFF

/
12

4 56 78 90 3
+ .

S332D

Figura 3-1. Sitio maestro o desactivar clave

Cable y modo de analizador de antena


Seleccin de la frecuencia
Para el mtodo calibracin OSL o FlexCal el rango de frecuencias para la medida deseada se debe establecer. El sitio maestro se establece automticamente la frecuencia cuando un particular se selecciona el nivel de seal, o la frecuencia se puede definir manualmente mediante el soft F1 y F2 claves. Para definir la frecuencia a un nivel de seal especfica para una calibracin OSL o FlexCal: Paso 1. Prensa el Frecuencia/DIST clave. Paso 2. Prensa el Seal estndar suave clave. Paso 3. Utilizar la/abajo para resaltar el nivel deseado, presione la Entrar clave para seleccionar. Para seleccionar manualmente el rango de frecuencia para una calibracin OSL o FlexCal: Paso 1. Prensa el Frecuencia/DIST clave.

Paso 2. Prensa el F1 suave clave. Paso 3. Escriba el texto deseado Inicio frecuencia mediante el teclado o la/pulsada la tecla de flecha. Paso 4. Prensa Entrar para establecer la F1 a la frecuencia deseada. Paso 5. Prensa el F2 suave clave. Paso 6. Introduzca la frecuencia de parada deseada mediante el teclado o la/pulsada la tecla de flecha. Paso 7. Prensa Entrar para establecer la F2 para la frecuencia deseada. Paso 8. Compruebe que las frecuencias start y stop muestra coincide con la medida deseada gama.

Calibracin
Mtodos de calibracin Para obtener resultados precisos, el sitio maestro debe calibrarse antes de tomar cualquier medida. El maestro de sitio debe ser re-calibrated cada vez que cambia la frecuencia de la instalacin, la temperatura supera el rango de temperatura de calibracin o cuando se quita el cable de extensin de puerto de prueba o de reemplazo. Los dos mtodos de calibrar el sitio maestro, FlexCal y OSL calibracin, pueden cada uno con ambos componentes discretos o con el mdulo InstaCal, proporciona cuatro tcnicas de calibracin para usuario mxima flexibilidad. FlexCal es una calibracin de frecuencia de banda ancha sigue siendo vlida si se cambia la frecuencia. Una calibracin OSL es abierto, Corto y cargar calibrado para un rango de frecuencia seleccionada, y es ya no es vlida si la frecuencia se cambia. El modo predeterminado de calibracin es OSL. Con cualquier mtodo de calibracin, el maestro del sitio puede calibrarse manualmente con abierto, Corto, componentes de calibracin de carga (OSL), o mediante el mdulo InstaCal.

3-2
Captulo 3 Introduccin Si se utiliza un Cable de extensin de puerto de prueba, el maestro del sitio deber calibrarse con la Cable de extensin de puerto de prueba en el lugar. El Cable de extensin de puerto de prueba es un cable estable de fase y se utiliza como un cable de extensin en el puerto de prueba para asegurar medidas precisas y repetibles. Este cable de fase estable puede se traslad y doblado al hacer una medicin sin causando errores en la medicin. Nota: El cable de extensin de puerto de prueba debe tener los conectores adecuados para la medicin. Uso de adaptadores de conector adicional despus del prueba de puerto cable de extensin puede contribuir a errores de medicin no compensados durante la calibracin.

Verificacin de calibracin
Durante el calibrado procesar a cambio el modo de prdida, ya sea con componentes discretos de calibracin o con el mdulo InstaCal, hay niveles de medicin tpico esperados. Comprobar los niveles de medicin aparecer en la pantalla durante la calibracin pueden ahorrar valioso tiempo en el campo. Seguimiento de caractersticas en el modo de prdida de retorno Como los componentes discretos calibracin estn conectados a la RF sitio maestro a puerto, el Despus de los niveles de medicin se mostrar en la pantalla: Cuando un abierto est conectado, aparecer una traza entre 0-10 dB. Cuando un corto est conectado, aparecer una traza entre 0-10 dB. Cuando carga un est conectado, aparecer una traza entre 0-50 dB. Cuando un mdulo de InstaCal est conectado a la RF sitio maestro a puerto, la siguiente medida los niveles se mostrar en la pantalla: Cuando el sitio maestro es medida equivalente abierto, se mostrar un seguimiento entre 0-20 dB. Cuando el sitio maestro es medir un corto equivalente, se mostrar un seguimiento entre 0-20 dB. Cuando el sitio maestro es medir una carga equivalente, se mostrar un seguimiento entre 0-50 dB. Los procedimientos siguientes explican mtodos estndar de calibracin de OSL, FlexCal y InstaCal.

Consulte la figura 3-2 para un diagrama de instalacin de calibracin. Captulo 3 Introduccin

3-3
Procedimientos de calibracin OSL
En Cable y modo de analizador de antena, si el Cal fuera se muestra el mensaje, o el puerto de prueba cable ha cambiado, se requiere un nuevo calibrado. El detalle de procedimientos siguientes cmo para realizar la calibracin OSL. Calibracin de OSL estndar Paso 1. Seleccione OSL Cal presionando el SYS clave, seguido por el Opciones de aplicacin tecla programable. El mtodo de calibracin seleccionado se indica en la parte inferior de la ventana de Estado. Uso del deModo de CAL tecla programable para seleccionar la calibracin OSL mtodo. Paso 2. Seleccione el rango de frecuencia adecuada, como se describe en la pgina 3-2. Paso 3. Prensa el Inicio de CAL clave de. El mensaje "Connect abierto o mdulo INSTACAL al puerto de salida de RF"aparecer en un cuadro de mensaje, con el tipo de calibracin en el barra de ttulo del cuadro de mensaje. Paso 4. Conectar el calibrado abrir y pulse el Entrar clave de. Los mensajes "medicin Abierto"y"Conectar corto y salida RF"aparecer. Paso 5. Eliminar el abierto, conectar el calibrado corto y pulse el Entrar clave de. La mensajes "Corto de medicin"y"Conectar la carga a la salida de RF"aparecer. Paso 6. Eliminar el corto, conecte la terminacin y prensa calibrado el Entrar clave de. El mensaje "Medir carga" aparecer. Sonar un tono audible Cuando la calibracin es completa. Paso 7. Verificar que se ha realizado correctamente la calibracin comprobando que la Cal ON ahora se muestra el mensaje en la esquina superior izquierda de la pantalla.

3-4
Captulo 3 Introduccin
MANTENGA EJECUTAR INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN MARCADOR DE LMITE GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN IMPRIMIR

MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS


ENTRAR CLARO ESCAPE ON OFF

/
12

4 56 78 90 3
+ .

S332D
ABIERTO CARGA Corto Calibracin

RFOUT/REFLEXIN PUERTO DE PRUEBA CABLE DE PUERTO DE PRUEBA (OPCIONAL)

Figura 3-2. El programa de instalacin de calibracin

Calibracin de FlexCal OSL Paso 8. El mtodo de calibracin seleccionado puede verse pulsando el SYS clave, seguido por el Estado tecla programable de. Para cambiar el mtodo de calibrado, seleccione el SYS clave, seguido por el Opciones de aplicacin tecla programable de. Uso el Modo de CAL tecla programable para seleccionar el FlexCal modo de calibrado. Paso 9. Prensa el Inicio de CAL clave de. El mensaje "Connect abierto o mdulo INSTACAL al puerto de salida de RF"aparecer en un cuadro de mensaje, con el tipo de calibracin en el barra de ttulo del cuadro de mensaje. Paso 10. Conectar el calibrado abrir y pulse el Entrar clave de. Los mensajes "medicin Abierto"y"Conectar corto y salida RF"aparecer y la frecuencia se establece automticamente en el sitio maestro de 25 MHz a 4000 MHz. Paso 11. Eliminar el abierto, conectar el calibrado corto y pulse el Entrar clave de. La mensajes "Corto de medicin"y"Conectar la carga a la salida de RF"aparecer.

Paso 12. Eliminar el corto, conecte la terminacin y prensa calibrado el Entrar clave de. El mensaje "Medir carga" aparecer. Sonar un tono audible Cuando la calibracin es completa. Paso 13. Verificar que se ha realizado correctamente la calibracin comprobando que la Sobre FlexCal ahora se muestra el mensaje en la esquina superior izquierda de la pantalla LCD.

Verificacin de mdulo de InstaCal


Comprobar el mdulo de InstaCal antes de cualquier lnea de barrido de las mediciones es fundamental para la datos medidos. Verificacin de mdulo de InstaCal identifica los errores en el mdulo debido a un circuito dao o el fracaso de los circuitos de control. Esta prueba no intenta caracterizar el mdulo InstaCal, que se realiza en la fbrica o el centro de servicio. El rendimiento del mdulo InstaCal puede ser verificado por el mtodo de terminacin o la Mtodo de desvo. El mtodo de terminacin es el mtodo preferido en el campo y similar para probar una carga mal contra una carga bien conocida. Mtodo de terminacin El mtodo de terminacin compara una carga de precisin contra el mdulo InstaCal y proporciona una lnea de base para otras mediciones de campo. Una carga de precisin proporciona mejor que 42 dB directividad. Paso 1. Establecer la frecuencia de acuerdo con el dispositivo bajo prueba (celular, PCS, GSM). Paso 2. Prensa el Modo clave y seleccione Prdida de retorno de alta frecuencia modo. Paso 3. Conectar el mdulo de InstaCal al puerto de salida de RF sitio maestro y calibrar la Maestro de sitio utilizando el mdulo de InstaCal (pgina 3-6). Paso 4. Extraiga el mdulo de InstaCal desde el puerto de salida de RF y conectar la precisin cargar a la RF puerto de salida. Paso 5. Prdida demedida el retorno de la carga de precisin. El nivel debe ser menos de 35 base de datos en toda la gama de frecuencia calibrado. Paso 6. Prensa el Marcador clave y definir el marcador M1 a Marcador de pico. El M1 valor debe ser inferior a la prdida de retorno de 35 dB. Paso 7. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar. Captulo 3 Introduccin

3-5
Mtodo de desvo Una alternativa para el mtodo de terminacin es medir la prdida de retorno de un desplazamiento de 20 dB. Esto es similar a una antena que se ha especificado para que un 20 dB devuelva prdida de medicin a travs de la frecuencia de operacin. Un desplazamiento de 20 dB proporciona una prdida de 20 dB devuelto a travs de una muy rango de frecuencias amplia. Medir la prdida de regreso con las 20 dB desplazamiento proporcionar un relativamente respuesta plana en toda la gama de frecuencia de funcionamiento del sitio maestro. Paso 1. Establecer la frecuencia de acuerdo con el dispositivo bajo prueba (celular, PCS, GSM). Paso 2. Prensa el Modo clave y seleccione Prdida de retorno de alta frecuencia modo. Paso 3. Conectar el mdulo de InstaCal al puerto de salida de RF sitio maestro y calibrar la Maestro de sitio utilizando el mdulo de InstaCal (pgina 3-6). Paso 4. Extraiga el mdulo de InstaCal desde el puerto de salida de RF y conectar el desvo de 20 dB a la RF puerto de salida. Paso 5. Medida la prdida de retorno de las 20 dB compensar. El nivel debe ser 20 dB, _2 dB en toda la gama de frecuencia calibrado. Paso 6. Prensa el Marcador clave y definir el marcador M1 a Marcador de pico. El M1 valor debe ser aproximadamente 20 dB prdida de retorno. Paso 7. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar.

Procedimientos de calibracin de mdulo de InstaCal


Nota: El mdulo de InstaCal no es un componente de calibracin discretos y puede no se utiliza en la parte superior de la torre para realizar mediciones de barrido de lnea. Comprobar que la CAL fuera mensaje que se muestra en la esquina superior izquierda de la ventana de Estado. Esto indica que no se ha calibrado el sitio maestro. El siguiente detalle de procedimientos

Cmo realizar una calibracin utilizando el mdulo InstaCal.

3-6
Captulo 3 Introduccin
InstaCal

InstaCal MDULO
Modelo ICN50 M 10 Hz-4.0 GHz MANTENGA EJECUTAR

INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN Lmite Marcador
GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN

IMPRIMIR MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS ENTRAR CLARO ESCAPE ON OFF

/ 12 4 56 78 90 3
+

S332D

Figura 3-3. Calibracin de mdulo de InstaCal

Calibracin estndar de InstaCal Paso 1. Seleccione OSL Cal presionando el SYS clave, seguido por el Opciones de aplicacin tecla programable. El mtodo de calibracin seleccionado se indica en la parte inferior de la ventana de Estado. Uso del deModo de CAL tecla programable para seleccionar la calibracin OSL mtodo. Paso 2. Seleccione el rango de frecuencia adecuada, como se describe en la pgina 3-2. Paso 3. Prensa el Inicio de CAL clave de. El mensaje "Connect abierto o InstaCal a RF A puerto"aparecer en un cuadro de mensaje, con el tipo de calibracin en el mensaje barra de ttulo del cuadro. Paso 4. Conectar el mdulo de InstaCal a la RF A Puerto (figura 3-3). Paso 5. Prensa el Entrar clave de. El maestro de sitio detecta el mdulo InstaCal y automticamente calibra la unidad mediante el procedimiento OSL. La calibracin debe tomar unos 45 segundos. Un tono audible sonar cuando se completa la calibracin. Paso 6. Verificar que se ha realizado correctamente la calibracin comprobando que la Cal De! mensaje que se muestra en la esquina superior izquierda de la ventana de Estado. Calibracin de FlexCal InstaCal Paso 1. FlexCal seleccione presionando el SYS clave, seguido por el Opciones de aplicacin tecla programable. El mtodo de calibracin seleccionado se indica en la parte inferior de la ventana de Estado. Uso del deModo de CAL tecla programable para seleccionar la calibracin de FlexCal mtodo. Paso 2. Prensa el Inicio de CAL clave de. El mensaje "Connect abierto o InstaCal a RF A puerto"aparecer en un cuadro de mensaje, con el tipo de calibracin en el mensaje barra de ttulo del cuadro. Paso 3. Puertoconectar el mdulo de InstaCal a la salida de RF (figura 3-3). El sitio maestro establece automticamente la frecuencia de 25 MHz a 4000 MHz. Paso 4. Prensa el Entrar clave de. El maestro de sitio detecta el mdulo InstaCal y automticamente calibra la unidad mediante el procedimiento OSL. La calibracin debe tomar unos 45 segundos. Un tono audible sonar cuando se completa la calibracin. Paso 5. Verificar que se ha realizado correctamente la calibracin comprobando que la FlexCal en! mensaje que se muestra en la esquina superior izquierda de la ventana de Estado.

Calibracin con el Cable de extensin de puerto de prueba


Si se utiliza un Cable de extensin de puerto de prueba, el maestro del sitio deber calibrarse con la Cable de extensin de puerto de prueba en el lugar. Siga los mismos procedimientos de calibracin como anteriormente con los componentes OSL o el mdulo de InstaCal en el lugar al final de la ampliacin del puerto de prueba cable. Captulo 3 Introduccin

3-7
Escala automtica
El sitio maestro puede establecer automticamente la escala a los valores mnimos y mximos de

la medicin en el eje del grfico. Esta funcin es especialmente til para las mediciones en modo de cables de acero. Para establecer la escala de manera automtica, pulse el Escala automtica clave. El sitio maestro establecer automticamente las escalas superiores e inferiores al mnimo y mximo valores de la medicin con algn margen en el eje de la pantalla LCD.

Escala de amplitud
El procedimiento siguiente define la visualizacin de escala superior e inferior. Paso 1. Prensa el Amplitud clave para abrir el men de la escala. Paso 2. Prensa el Top suave clave y utilizar el teclado o arriba/abajo la tecla de flecha para editar la parte superior valor de escala de. Prensa entrar al conjunto. Paso 3. Prensa el Parte inferior tecla programable y utilizar el teclado o arriba/abajo la tecla de flecha para editar el valor de escala deinferior. Prensa entrar al conjunto. Nota: Normalmente la escala del eje y del grfico es 0-60 dB (prdida de retorno) pero para algunas mediciones (por ejemplo, prdida de insercin) puede cambiar la escala a 0-10 dB. Si no se cambia la escala, algunos resultados de la medicin no pueden ser puede verse fcilmente en la pantalla.

Definir la distancia y el tipo de Cable


En modo de error de distancia (DTF), la longitud de la lnea de transmisin (distancia) y cable se selecciona el tipo. El tipo de cable determina la atenuacin de propagacin y cable de velocidad factor. El siguiente procedimiento puede utilizarse para establecer la distancia y seleccione el apropiado tipo de cable. Nota: Al seleccionar el cable correcto es muy importante para mediciones precisas y para identificar las fallas en la lnea de transmisin. Seleccionar el cable incorrecto, o utilizando el cable correcto de su tipo de caractersticas de frecuencia adecuada, cambiar la traza DTF vertical y horizontalmente haciendo difcil de localizar con precisin fallas. Paso 1. Prensa el Modo clave. Paso 2. Seleccione DTF volver prdida o dtf swr modo de. Establece automticamente el sitio maestro D1 a cero. Paso 3. Prensa el D2 suave clave. Paso 4. Escriba el valor adecuado de D2 para la longitud mxima de la lnea de transmisin y pulse el Entrar clave para establecer el valor de la D2. Paso 5. Prensa el DTF ayuda suave clave.

3-8
Captulo 3 Introduccin Paso 6. Con la Arriba/abajo la tecla de flecha, seleccione el Cable = y pulse Entrar. Uso del Arriba/abajo la tecla de flecha para seleccionar el Estndar tipos de cable almacenados en el sitio estndar Listas de cable maestro (que no se pueden editar) o elija Custom, para cables adicionales. Una lista personalizada de cable puede crearse y cargado mediante el Software de mano Aplicacin de herramientas proporcionada con el sitio maestro (captulo 10). Paso 7. Con la Arriba/abajo flecha clave, seleccione el tipo de cable y prensa apropiado el Entrar clave de. El tipo de cable seleccionado, Prop Vel y prdida de Cable en dB/m (o dB/ft) se mostrar en la pantalla de parmetros DTF. Paso 8. Prensa Entrar. Captulo 3 Introduccin

3-9

Todos los modos


Guardar y recuperar una instalacin
Guardar una configuracin

Guardar una configuracin de instalacin de analizador de cable y antena en memoria a preservar la calibracin informacin. Paso 1. Para guardar la configuracin en uno de los lugares de instalacin de usuario disponible, pulse Guardar configuracin. Hay diez localidades en cable y antena analizador modos. Paso 2. Utilizar el teclado o el arriba/abajo la tecla de flecha para seleccionar una ubicacin. Paso 3. Prensa Entrar para guardar la configuracin. Nota: Modos de analizador de cable y antena, se guarda una calibracin OSL con una designacin de OSL, una calibracin OSL InstaCal se guarda con un OSL!, un Calibracin de FlexCal OSL se guarda con un FLX y una calibracin InstaCal FlexCal se guarda con un FLX!.

Recordando una configuracin


El siguiente procedimiento recuerda una configuracin de memoria. Paso 1. Prensa el Recordar la configuracin clave. Paso 2. Seleccione la configuracin deseada mediante la/pulsada la tecla de flecha. Paso 3. Prensa Entrar recordar la configuracin. Nota: Se muestran slo las configuraciones desde el modo actual.

Guardar y recordar una pantalla


Guardar una presentacin
El procedimiento siguiente guarda una pantalla en la memoria. Paso 1. Prensa el Guardar visualizacin clave para activar el men alfanumrico para seguimiento almacenamiento de informacin. Paso 2. Utilice las teclas para introducir una etiqueta para el seguimiento guardados. Por ejemplo, para guardar una pantalla con la prensa de "Prdida de volver TX1" nombre del Grupo clave suave que contiene la letra "T" y pulse la tecla programable "T". Pulse la suave grupo clave que contiene la letra "X", a continuacin, presione la tecla programable "X". Pulse la el nmero de tecla "1" en el teclado numrico. Utilice las teclas programables y teclado segn sea necesario Escriba el nombre completo, presione Entrar para completar el proceso.

3-10
Captulo 3 Introduccin Notas: Ms de una traza se puede guardar con el mismo alfanumricos nombre, como huellas se almacenan cronolgicamente, mediante el sello de fecha y hora. Presionando el Guardar visualizacin clave aparecer el apellido de seguimiento guardados en la lnea de entrada. Pulsando la tecla programable de eliminar borrar el nombre todo rastro. Para borrar slo un carcter de un nombre de seguimiento, la de prensa/pulsada la tecla de flecha para Seleccione el carcter y, a continuacin, pulse la tecla programable de eliminar. Esta funcin puede ser til al asignar nombres a huellas secuencialmente, tales como: seguimiento de 1, 2 de seguimiento, etc..

Recordando una pantalla


El siguiente procedimiento recuerda una pantalla previamente guardada de la memoria. Paso 1. Prensa el Recordar la visualizacin clave. Paso 2. Seleccione la pantalla deseada mediante la/pulsada la tecla de flecha. Paso 3. Prensa Entrar recordar la visualizacin.

Cambio de las unidades


De forma predeterminada, el maestro del sitio muestra informacin en unidades mtricas. Utilice el procedimiento siguiente para cambiar la visualizacin a unidades inglesas en el modo de analizador de cable y antena. Paso 1. Prensa el SYS clave. Paso 2. Seleccione el Opciones de sistema suave clave. Paso 3. Prensa el Unidades tecla programable para cambiar de mtrica a unidades de medida inglesa, o viceversa. La seleccin actual se muestra en la esquina inferior izquierda de la pantalla.

Cambiar el idioma

De forma predeterminada, el maestro del sitio muestra mensajes en ingls. Para cambiar el idioma de visualizacin: Paso 1. Prensa el SYS clave. Paso 2. Seleccione el Idioma suave clave. Paso 3. IdiomaSeleccione la deseada. Las opciones son ingls, francs, alemn, espaol, Chino y japons. El idioma predeterminado es ingls.

Ajustar marcadores
Paso 1. Prensa el Marcador clave para abrir el men de marcadores. Paso 2. Prensa el M1 tecla programable para seleccionar la funcin de marcador de M1. Paso 3. Prensa el Editar suave clave e introduzca un valor adecuado mediante el teclado o Arriba/abajo la tecla de flecha para mover el marcador sin volver a dibujar el trazo. Urgente el Encendido/apagado tecla programable activa o desactiva la funcin de marcador de M1. Paso 4. Prensa el Volver tecla programable para volver al men de marcadores. Paso 5. Repita los pasos para marcadores M2, M3, M4, M5 y M6. Captulo 3 Introduccin

3-11
Ajuste de lmites
El maestro de sitio ofrece dos tipos de lmites: un nico horizontal limitar la lnea y segmentado lmites. Ajuste de un nico lmite Paso 1. Prensa el Lmite clave. Paso 2. Prensa el Lmite nico suave clave. Paso 3. Prensa el Editar suave clave. Paso 4. Introducir el valor mediante el teclado numrico o desplazarse a la lnea de lmite utilizando el Arriba/abajo la tecla de flecha. Paso 5. Prensa Entrar para establecer la ubicacin de la lnea de lmite. Ajuste de lmites segmentadas Lneas de lmite segmentada se definen por separado como cinco segmentos de lmite superior y el inferior cinco limitar los segmentos. Esto permite la definicin de una mscara espectral. Un segmento de lmite se define por sus extremos. Es decir, desde la frecuencia, amplitud, a partir terminando con frecuencia y aboliendo la amplitud. Este procedimiento describe la configuracin de dos superior limitar los segmentos. Los pasos pueden ser prorrogados a los dems lmite superior segmentos, as como a los segmentos de lmite inferiores. Paso 1. Prensa el Lmite clave. Paso 2. Prensa el Varios lmites superior suave clave. Paso 3. Prensa el Segmento 1 suave clave. Paso 4. Prensa el Editar tecla programable de. La ventana de estado sucesivamente muestra el valor de los extremos del segmento: Iniciar Freq, lmite de comienzo, fin Freq, lmite final. Paso 5. Editar cada valor con el teclado numrico o desplazamiento de la lnea de lmite utilizando el Arriba/abajo, prensa y la tecla de flecha Entrar al conjunto. Paso 6. Prensa el Siguiente segmento tecla programable depara pasar al segmento 2. Si el estado del segmento 2 es OFF, presionando la Siguiente segmento tecla programable se establece automticamente el Inicio del segmento 2 igual hasta el punto final del segmento 1. Paso 7. Repita estos pasos para los dems segmentos. Paso 8. Cuando se define el segmento final, pulse el Volver tecla programable para poner fin a la edicin proceso.

3-12
Captulo 3 Introduccin Notas: El sitio maestro no permite la acumulacin de segmentos de lmite de la mismo tipo. Es decir, superponen dos segmentos de lmite superior y dos lmite inferior no se pueden superponer segmentos.

El maestro de sitio tambin permite segmentos de lmite vertical. Un segmento de lmite que las frecuencias inicial y final son lo mismo, pero los valores lmite son diferentes, no se puede especificar. Habilitar el sonido de lmite Ambos tipos de lmite pueden indicar una violacin del lmite habilitando el lmite de sonido. Un audible "bip" sonar en cada punto de datos que infringe el lmite definido. Paso 1. Prensa el Lmite clave (nmero 7 del teclado numrico). Paso 2. Prensa el Limitar el sonido tecla programable de. La ventana de Estado que indica el estado de el sonido de lmite es de, y la tecla programable permanecer en el Estado "hacia abajo". Pulse la Limitar el sonido tecla programable de nuevo para desactivar el sonido de lmite.

Ajustar el brillo de la pantalla


Puede ajustar el brillo de la pantalla para adaptarse a diferentes condiciones de luz y para ayudar a discernir huellas. Paso 1. Pulse la tecla de la bombilla (nmero 1 del teclado numrico). Paso 2. Ajustar el brillo utilizando la/pulsada la tecla de flecha. Paso 3. Prensa Entrar para guardar la nueva configuracin. Captulo 3 Introduccin

3-13

Impresin
Impresin se consigue seleccionando una impresora disponible y presionando la tecla Imprimir como se describe a continuacin. Consulte la impresora particular funcionamiento manual para la configuracin de impresora especfica.

Imprimir una pantalla


Paso 1. Obtener la visualizacin de medicin deseado. Paso 2. Prensa el SYS clave y la Opciones de sistema suave clave. Paso 3. Prensa el Impresora tecla programable y seleccione en el men Mostrar de impresoras compatibles. Paso 4. Prensa el Imprimir clave. Paso 5. Conectar la impresora, como se muestra en la figura 3-4.

Configuracin del conmutador de impresora


Establecer los modificadores del cable de interfaz serie a paralelo a la inyeccin de tinta HP Deskjet 450 impresora como sigue:

3-14
Captulo 3 Introduccin
HP DESKJET IMPRESORA SERIE A PARALELO SITIO PRINCIPAL CABLE DE INTERFAZ
MANTENGA EJECUTAR INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN MARCADOR DE LMITE GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN IMPRIMIR MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS ENTRAR CLARO ESCAPE ON OFF

/ 12 4 56 78 90 3
+ .

S332D

Figura 3 - 4-. Configuracin de impresora del sitio maestro SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DESCUENTO DE SOBRE FUERA FUERA APAGADO OFF ON FUERA

Usando el maletn blando


Ha sido diseado el maletn blando que la correa puede ser unsnapped para permitir la caso para orientarse fcilmente horizontal; lo que permite que los controles de Anritsu para ser ms fcilmente visitada (figura 3-5). Captulo 3 Introduccin

3-15
Figura 3-5. Utilizando el sitio maestro de Soft maletn

Captulo 4 Cable y antena Mediciones del analizador


Introduccin
Este captulo proporciona una descripcin de las medidas de analizador de cable y la antena, incluyendo lnea de barrido de fundamentos y lnea de barrido procedimientos de medicin, disponibles cuando la Sitio principal est en modo DTF o frecuencia.

Fundamentos de barrido de lnea


En inalmbrico de comunicacin, la transmisin y recepcin antenas estn conectadas a la radio a travs de una lnea de transmisin. Esta lnea de transmisin es generalmente un cable coaxial o gua de onda. Este sistema de conexin se conoce como una transmisin sistema de lnea de alimentacin. Figura 4-1 muestra un ejemplo de una transmisin tpico sistema de lnea de alimentacin.

4-1
Figura 4-1. Un sistema tpico de lnea de alimentacin de transmisin

El rendimiento de un sistema de lnea de alimentacin de transmisin puede verse afectado por la reflexin de seal excesivo y la prdida de cable. Seal de reflexin se produce cuando la seal RF refleja debido a un discrepancia de impedancia o cambio en la impedancia causada por estrangulamiento o plegado de excesivo la lnea de transmisin. Prdida de cable es causada por la atenuacin de la seal de su paso por la lnea de transmisin y conectores. Para comprobar que el rendimiento de la transmisin del sistema de lnea de alimentacin y analizar estos problemas, tres tipos de barridos de lnea son necesarios: Volver a medicin de prdida Mide la potencia reflejada del sistema en decibelios (dB). Tambin se puede adoptar esta medida en el modo de relacin de onda estacionaria (SWR), que es el relacin entre la potencia transmitida a la potencia reflejada. Medicin de prdida de cable Mide la energa absorbida, o perdido, por la lnea de transmisin en dB/metro o dB/pies de transmisin diferentes lneas tienen prdidas diferentes, y la prdida es con frecuencia y distancia especfica. Cuanto mayor sea la frecuencia o ms la distancia, la mayor la prdida. Medicin de la distancia a fallas (DTF) Revela la ubicacin precisa de fallas de componentes en el sistema de lnea de transmisin. Este examen ayuda a identificar problemas especficos en el sistema, tales como las transiciones del conector, puentes, kinks en la intrusin de cable o humedad. Las diferentes mediciones se definen como: Devolver la prdida - sistema de barrido Una medida cuando la antena est conectada a la final de la lnea de transmisin. Esta medida ofrece un anlisis de cmo los distintos componentes del sistema estn interactuando y proporciona una total prdida de retorno de todo el sistema. Distancia de fallas-carga barrido Una medicin se hace con la antena desconectada y reemplazado con un 50_ precisin de carga al final de la lnea de transmisin. Esta medida permite el anlisis de los diversos componentes de la transmisin alimentan el sistema de lnea en el Modo DTF. Prdida de cable de barrido Una medicin cuando se conecta un poco al final de la

lnea de transmisin. Esta condicin permite el anlisis de la prdida de la seal a travs de la transmisin lnea e identifica los problemas en el sistema. Prdida de alta insercin en la lnea de alimentacin o puentes puede contribuir al sistema pobre desempeo y prdida de cobertura. Todo este proceso de mediciones y probar el sistema de lnea de transmisin se denomina lnea Barrido.

4-2
Captulo 4 Cable y mediciones de antena

Inmunidad de CW modo/RF
Modo CW puede utilizarse para maximizar la velocidad de barrido de frecuencia y mediciones de DTF. Con CW en, tiempos de barrido pueden ser dos veces ms rpidos que con CW fuera. Sin embargo, hacer mediciones con CW voluntad reducen la inmunidad del instrumento para interferir las seales. En un entorno controlado, esto reduce inmunidad no debera ser un problema. En el campo Sin embargo, puede haber seales aisladas de transmisores cercanas o posicionar que pueden afectar frecuencia y mediciones de DTF. Encendido y apagado de CW puede comprobar que el sitio maestro est reduciendo las seales interfieran. Si no hay ninguna diferencia apreciable, entonces debera ser seguro para hacer mediciones con CW en. Use esta caracterstica con precaucin, como podra ser confundido con la introduccin posterior de una seal interfiere por un problema con la antena o cable ejecutar. Si CW est en una medicin RL o SWR normal, el maestro del sitio ser ms susceptible para interferir las seales. Seales interfieran pueden hacer la medicin mejor o peor lo que realmente es.

Informacin necesaria para un lnea de barrido


La siguiente informacin debe determinarse antes de intentar una medicin de barrido de lnea: Rango de frecuencias de sistema, para definir la frecuencia de barrido Tipo de cable, para establecer las caractersticas de cable para las mediciones de DTF Distancia de Cable ejecutar, para establecer la distancia para mediciones DTF

Procedimientos de ensayo de barrido de lnea tpico


Esta seccin proporciona tpica lnea de barrido las medidas utilizadas para analizar el rendimiento de sistema de lnea de alimentacin de una transmisin.

Medicin de prdida de retorno del sistema


Sistema volver medicin prdida comprueba el rendimiento de la transmisin en el sistema de lnea de alimentacin con la antena conectada al final de la lnea de transmisin. Para medir el sistema prdida de devolucin: Equipo necesario Sitio maestro modelo S331D Precisin abierto/corto, Anritsu 22N50 o Precisin abierto/corto/carga, Anritsu OSLN50-1 o Mdulo de InstaCal ICN50B Carga de precisin, Anritsu SM/PL-1 Cable de extensin de puerto de prueba, Anritsu 15RNFN50-1,5-R Adaptador opcional 510-90, DC a 7,5 GHz, 50 ohm, 7/16(F)-N(M) Dispositivo de ensayo Lnea con antena de alimentacin de transmisin Captulo 4 Cable y mediciones de antena

4-3
Procedimiento Paso 1. Prensa el Modo clave. Paso 2. Seleccione Prdida de retorno de alta frecuencia utilizando la/pulsada la tecla de flecha y prensa Entrar. Paso 3. Establece el inicio y parada frecuencias, automticamente al seleccionar un nivel de seal o manualmente utilizando las teclas F1 y F2, como se describe en la pgina 3-2.

Paso 4. Calibrar el sitio maestro, tal como se describe en la pgina 3-2. Paso 5. Conectar el dispositivo bajo prueba para el sitio maestro. Se mostrar una traza en la pantalla cuando el maestro de sitio est en el modo de barrido. Paso 6. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar. Nota: La antena debe estar conectada al final de la lnea de alimentacin de transmisin al realizar una medicin de prdida de retorno del sistema. Figura 4-2 es un ejemplo de un sistema tpico prdida retorno medicin seguimiento mediante un FlexCal calibracin: Nota: La traza de barrido de sistema debe aparecer en una prdida aproximada de retorno de 15 dB (_3 dB) en la ventana de Estado. Por lo general, mayor que una prdida de retorno de 15 dB se mide en el paso de los sistema de antena.

4-4
Captulo 4 Cable y mediciones de antena
Figura 4-2. Seguimiento de prdida de retorno del sistema tpico

Medicin de prdida de cable


La prueba de prdida de insercin de alimentacin de lnea de transmisin verifica el nivel de atenuacin de la seal del cable sistema de referencia a la especificacin. Esta prueba puede realizarse con el sitio maestro en el modo de la prdida de FreqCable. Equipo necesario Sitio maestro modelo S331D Precisin abierto/corto, Anritsu 22N50 o Precisin abierto/corto/carga, Anritsu OSLN50-1 o Mdulo de Anritsu InstaCal, ICN50B Carga de precisin, Anritsu SM/PL-1 Cable de extensin de puerto de prueba, Anritsu 15RNFN50-1,5-R Adaptador opcional 510-90, DC a 7,5 GHz, 50 ohm, 7/16(F)-N(M) Dispositivo de ensayo Transmisin alimentar lnea con corto Procedimiento - modo de prdida de Cable Paso 1. Prensa el Modo clave. Paso 2. Seleccione Prdida de Cable de alta frecuencia utilizando la/pulsada la tecla de flecha y prensa Entrar. Paso 3. Establece el inicio y parada frecuencias, automticamente al seleccionar un nivel de seal o manualmente utilizando las teclas F1 y F2, como se describe en la pgina 3-2. Paso 4. Conectar la ampliacin del puerto de prueba cable al puerto RF y calibrar el sitio Maestro como se describe en la pgina 3-2. Paso 5. Guardar la calibracin configurar (pgina 3-10). Paso 6. Conectar el dispositivo bajo prueba a la fase de sitio maestro estable ampliacin del puerto de prueba cable. Una traza se mostrar en la pantalla mientras el maestro del sitio es en el modo de barrido. Paso 7. Prdida de cable se muestra en la ventana de Estado. Paso 8. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar. Captulo 4 Cable y mediciones de antena

4-5
Figura 4-3 es un ejemplo de una transmisin tpica lnea cable prdida medicin seguimiento mediante un calibracin estndar.

4-6
Captulo 4 Cable y mediciones de antena
Figura 4-3. Tpico prdida traza de lnea Cable de transmisin

Prueba de lnea de transmisin de distancia a fallas (DTF)


La prueba de lnea de transmisin de distancia a fallas comprueba el rendimiento de la transmisin lnea de la Asamblea y sus componentes e identifica las ubicaciones de fallas en la lnea de transmisin sistema. Esta prueba determina el valor de retorno de prdida de cada par de conector, componente de cable

y cable para identificar la ubicacin del problema. Este examen se puede realizar en el DTF Return Modo de prdida o DTFSWR. Normalmente, para aplicaciones de campo, es el modo de prdida de DTF Return utiliza. Para realizar este examen, desconectar la antena y conectar la carga al final de la lnea de transmisin. Equipo necesario Sitio maestro modelo S331D Precisin abierto/corto, Anritsu 22N50 o Precisin abierto/corto/carga, Anritsu OSLN50-1 o Mdulo de Anritsu InstaCal, ICN50B Carga de precisin, Anritsu SM/PL-1 Cable de extensin de puerto de prueba, Anritsu 15RNFN50-1,5-R Adaptador opcional 510-90, DC a 7,5 GHz, 50 ohm, 7/16(F)-N(M) Dispositivo de ensayo Lnea con carga de alimentacin de transmisin Modo de procedimiento - DTF - prdida de retorno Los siguientes pasos explican cmo hacer una medicin DTF en modo de prdida de retorno. Paso 1. Prensa el Modo clave. Paso 2. Seleccione Prdida DTF-retorno utilizando la/pulsada la tecla de flecha y prensa Entrar. Paso 3. Conectar la ampliacin del puerto de prueba cable al puerto RF y calibrar el sitio maestro como se describe en la pgina 3-2. Paso 4. Guardar la calibracin configurar (pgina 3-10). Paso 5. Conectar el dispositivo bajo prueba a la fase de sitio maestro estable ampliacin del puerto de prueba cable. Una traza se mostrar en la pantalla mientras el maestro del sitio es en el modo de barrido. Paso 6. Prensa el Frecuencia/DIST clave. Paso 7. Establece el D1 y D2 valores de. El valor por defecto del sitio maestro para D1 es cero. Paso 8. Prensa el DTF ayuda tecla programable y seleccione el apropiado Tipo de cable para establecer la factor de atenuacin y la velocidad de propagacin correcta. Nota: Al seleccionar la velocidad de propagacin de derecha, el factor de atenuacin y la distancia es muy importante para mediciones precisas, de lo contrario que las fallas no pueden ser identificado con precisin. Paso 9. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar. Paso 10. Grabar las transiciones de conector. Captulo 4 Cable y mediciones de antena

4-7
Figura 4-4 muestra un ejemplo de una tpica DTF prdida retorno medicin seguimiento mediante un Calibracin de FlexCal. En el ejemplo anterior: Marker M1 marca el primer conector, el final del sitio maestro fase estable prueba Cable de extensin de puerto. Marcador M2 marca el primer cable de puente. Marcador M3 marca el fin de que el cable de alimentacin principal. Marcador M4 es la carga al final de la lnea de transmisin completa. Procedimiento - modo DTF-SWR Los siguientes pasos explican cmo medir DTF en modo de cables de acero. Paso 1. Prensa el Modo clave. Paso 2. Seleccione el dtf-swr utilizando la/pulsada la tecla de flecha y prensa Entrar. Paso 3. Siga el mismo procedimiento como modo de DTF-regreso de prdida, por encima de.

Resolucin
Hay tres conjuntos de puntos de datos (130, 259 y 517) disponible en el sitio maestro. La fbrica valor por defecto es 259 puntos de datos. Aumentando el nmero de datos puntos la medicin distancia de lnea de precisin y transmisin para medir aumentar. Paso de tamao = (1,5108) (Vp)

F Donde Vp es la velocidad de propagacin relativa del cable y f es la frecuencia de parada menos la frecuencia de inicio (Hz). Es la distancia mxima: DMax = tamao de paso _ (# de datapoints: 1)

4-8
Captulo 4 Cable y mediciones de antena
Figura 4-4. Seguimiento de prdida de retorno de DTF tpico

Aumentar los puntos de datos aumenta el tiempo de barrido y aumenta la precisin de la medicin. Modo CW o desactivar tambin puede afectar a la velocidad de barrido (vase modo CW, pgina 4-3 para detalles).

Prueba de prdida de retorno de subsistema de antena


Subsistema de antena volver medicin prdida comprueba el rendimiento de la transmisin y recibir antenas. Esta medida puede utilizarse para analizar el rendimiento de la antena antes de la instalacin. La antena puede ser probada para la banda de frecuencia todo, o probada a un rango de frecuencia especficos. Transmitir y recibir la frecuencia de las mediciones se realizan por separado. Los siguientes pasos explican cmo medir la prdida de antena en el modo de prdida de retorno. Equipo necesario Sitio maestro modelo S331D Precisin abierto/corto, Anritsu 22N50 o Precisin abierto/corto/carga, Anritsu OSLN50-1 o Mdulo de Anritsu InstaCal, ICN50B Carga de precisin, Anritsu SM/PL-1 Cable de extensin de puerto de prueba, Anritsu 15RNFN50-1,5-R Adaptador opcional 510-90, DC a 7,5 GHz, 50 ohm, 7/16(F)-N(M) Dispositivo de ensayo Antena Sub Asamblea Procedimiento Paso 1. Prensa el Modo clave. Paso 2. Seleccione Prdida de retorno de alta frecuencia utilizando la/pulsada la tecla de flecha y prensa Entrar. Paso 3. Conectar la ampliacin del puerto de prueba cable al puerto RF y calibrar el sitio Maestro como se describe en la pgina 3-2. Paso 4. Prensa Guardar configuracin y guardar la calibracin configurar (pgina 3-10). Paso 5. Conectar el dispositivo bajo prueba a la fase de sitio maestro estable ampliacin del puerto de prueba cable. Paso 6. Prensa el Marcador clave. Paso 7. Definir marcadores M1 y M2 con la frecuencia deseada. Paso 8. Grabar la menor prdida de retorno durante el intervalo de frecuencia especificado. Paso 9. Prensa Guardar visualizacin nombre (pgina 3-10) el seguimiento y la prensa Entrar. Captulo 4 Cable y mediciones de antena

4-9
La siguiente traza es un ejemplo de una antena prdida retorno medicin seguimiento mediante un Calibracin de FlexCal... Calcular el valor de umbral y comparar la prdida de volver ms baja registrada a la calculada valor de umbral. Prdida de retorno mximo =


20 1 1 registro VSWR VSWR

NOTAS: VSWR es VSWR especificado del fabricante de la antena. Utilizar herramientas de Software de computadora de mano para convertir VSWR volver prdida o prdida de volver a VSWR. Si la medida volver la prdida es menor que el valor de umbral calculado, falla la prueba y la antena debe ser reemplazado.

4-10
Captulo 4 Cable y mediciones de antena
Figura 4-5. Seguimiento de prdida de retorno de antena

Captulo 5 Modo de Monitor de energa


Introduccin
El maestro de sitio con la opcin 5 instalado puede usarse para realizar medidas de poder con detectores de RF banda ancha, como los 10 MHz a 20 GHz Anritsu 560-7N50B. Consulte la tabla detectores de RF disponibles en la pgina 1-3. El monitor de potencia muestra los resultados de la potencia medida en dBm o Watts.

Medicin de potencia
Equipo necesario Sitio maestro modelo S331D con opcin de Monitor de potencia Detector de banda ancha de RF, Anritsu P/n 5400-71N50 30 dB, 50 vatios, bidireccional, DC 18 GHz, N(m) N(f), atenuador, 42N50A-30 Procedimiento Paso 1. Prensa el Encendido/apagado clave en el sitio maestro. Paso 2. Prensa el Modo clave. Paso 3. Use las/pulsada la tecla de flecha para seleccionar el modo de Monitor de potencia y prensa Entrar. Reduccin a cero del Monitor de potencia Paso 4. Con ninguna potencia aplicada a la DUT, pulse el Cero tecla programable de la potencia men. Espere unos segundos mientras el sitio maestro acumula muestras de datos de el poder inactivo. Cuando haya terminado, cero ADJ: en se muestra en el mensaje rea. Medicin de altos niveles de energa de entrada Paso 5. Insertar un atenuador entre el DUT y el detector de RF para proteger el sitio Principal para que el nivel de potencia de entrada es inferior o igual a 20 dBm. Paso 6. Prensa el OFFSET suave clave. Paso 7. Entrar la atenuacin en dB mediante el teclado. Prensa el entrar clave para completar la entrada. Se mostrar el rea de mensajes REL: ON junto con el valor introducido en base de datos. Mostrar poder en dBm y Watts Paso 8. Prensa el Unidades tecla programable para mostrar la potencia en vatios.

5-1
Mostrar poder relativo Paso 9. Con la entrada de nivel deseado poder de base para el sitio maestro, pulse el REL suave clave de. Se mostrar el rea de mensajes REL: ON y el poder leer indicar 100%. Paso 10. Prensa el Unidades tecla programable depara mostrar el poder de dBm. Desde REL es ON, el poder lectura ser en dBr, relativa al nivel de potencia de base.

5-2
Monitor de potencia del captulo 5

Captulo 6 Medidor de corriente de alta precisin


Introduccin
Medidor de la energa de la alta precisin de Anritsu (opcin 19) permite alta precisin, RMS mediciones de CW y seales digitalmente moduladas como CDMA/EV-DO, GSM/EDGE y WCDMA/HSDPA. Esta opcin requiere PSN50 o MA24104A sensores de alimentacin. El sensor de PSN50 proporciona mediciones de terminacin de alta precisin de 50 MHz a 6 GHz con un rango dinmico de dBm de 30 a + 20 dBm. La MA24104A es un sensor de alta potencia en lnea con un rango de frecuencia de 600 MHz a 4 GHz y puede seales de medida tan altas como 150W. Ambos de los sensores de poder estn equipados con un RS232 interfaz de conexin rpida y fcil para el sitio maestro.

Unidades y poder relativo


La pantalla muestra los valores de energa en dBm y Watts. La funcin de poder relativo muestra los cambios de poder con respecto a un valor de referencia en la base de datos y %.

Lneas de lmite
Lmites pueden utilizarse para determinar si es una medida dentro de lmites especificados y que se ejecuta con un promedio de est disponible junto con Max/bloqueo y ejecutar/bloqueo.

El Sensor de conexin
El medidor de energa opcin 19 alta precisin se conecta a la potencia de PSN50 o MA24104A sensor mediante un cable RS232 (Anritsu parte nmero 800-441). Un Vcc de 9 a 18 (< 100 mA) fuente de alimentacin es necesaria para cualquier sensor (el sensor MA24104A tambin puede ser funciona con tres pilas AA). Fuente de alimentacin de Anritsu (40-168-R), suministrado con el sitio Maestro, es recomendable.

6-1
Figura 6-1. Pantalla de medicin de potencia de alta precisin

Reduccin a cero del Sensor


La funcin de cero mejora la precisin de bajo nivel mediante la eliminacin de ruido del sistema medida. Cal Factores corrigen tanto la eficiencia como la prdida de la discrepancia. Debe ingresar la informacin de frecuencia para obtener el factor de calibrado correctamente.

Utilizando atenuadores
Cuando sea necesario, atenuadores deben utilizarse para garantizar que el poder no supera el rango de medida especificada. La funcin de base de datos de desplazamiento puede utilizarse para especificar el valor de cualquier cables y atenuadores.

Medicin de potencia
Equipo necesario S331D sitio maestro Cable serie RS232, Anritsu P/N 800-441 Fuente de alimentacin, Anritsu P/N 40-168-R PSN50 o Sensor de MA24104A 30 dB, 50W, bidireccional, DC-8.5 GHz, N(m)-N(f), atenuador, 3-1010-123 Procedimiento Paso 1. Conectar el RS232 cable serie entre el sensor y el maestro de sitio serial puerto. Paso 2. Fuente de alimentacin de conectar la DC a la DC de entrada de los PSN50 o MA24104A.

Paso 3. Prensa el Encendido/apagado clave en el sitio maestro. Paso 4. Prensa el Modo clave. Paso 5. Uso de la clave de la flecha arriba o abajo para seleccionar Medidor de corriente de alta precisin modo y pulse Entrar.

6-2
Captulo 6 alta precisin poder Meter
MANTEN GA EJECUT AR INICIO CAL Automtic o ESC ALA GUARD AR EL PR OGR AMA D E INST ALACIN RECORD AR EL PR OGR AMA D E INST ALACIN MARCAD OR D E LMIT E GUARD AR VISU ALIZ ACIN RECORD AR VISU ALIZ ACIN IMPRIMIR

MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS


ENTRAR CLAR O ESC APE ON OFF

/
12

4 56 78 90 3
+.

MT8212A CeldaMaestro

S332D ATENUADOR

DUT
RF CABO PSN50 SENSOR CC MA24104A SENSOR CARGA

Figura 6-2. Alta precisin poder Meter instalacin

Cero y Cal Paso 6. Prensa el Frecuencia/DIST clave. Paso 7. Para especificar la frecuencia manualmente utilizando las teclas numricas, seleccione el Centro suave clave de. Para seleccionar un nivel de seal conocida, pulse el Seal estndar tecla programable y Utilice la arriba/abajo la tecla de flecha para seleccionar el nivel deseado. Sern los factores de Cal se deriva de la frecuencia central correspondiente. Nota: El nmero de canal no es necesario porque la cal factor de frecuencias se redondean al ms cercano 500 MHz. Paso 8. Sin poder aplicado en el sensor, pulse el Amplitud clave de la Cero tecla programable a cero el sensor. Puesta a cero el sensor se recomienda al hacer medicin de potencia por debajo de 20 dBm. Utilizando atenuadores Paso 9. Prensa el Amplitud clave y seleccione la Desplazamiento de dB suave clave. Paso 10. Conectar el cable de fase estable y el atenuador entre el DUT y el sensor. Paso 11. Introduzca el valor combinado de desvo de la atenuador y la almohadilla o seleccione el Desplazamiento de medida tecla programable para utilizar el Kit de Cal de desplazamiento (65701) para medir el desplazamiento. Consulte la pgina para obtener ms detalles. Promediando/Max mantenga/ejecutar espera Paso 12. Prensa el meas/disp clave. Paso 13. Prensa el Ejecutando promedios tecla programable y utilizar el teclado para introducir el nmero de promedios a utilizar (hasta 50). Paso 14. Prensa el Max espera tecla programable depara mostrar el valor mximo. Si se selecciona Averaging, Max/bloqueo mostrar el valor mximo de los datos no promedi. Paso 15. Prensa el Ejecutar/bloqueo clave para mantener la pantalla en la condicin actual. Establecimiento de lmites Paso 16. Prensa el meas/disp clave. Paso 17. Prensa el Unidades de lmite tecla programable para seleccionar las unidades. Paso 18. Prensa el Lmite inferior suave clave y escriba el valor lmite inferior en dBm o en Watts. Paso 19. Prensa el Lmite superior suave clave e introduzca el valor de lmite superior en dBm o en Watts.

Paso 20. Prensa el Lmite de encendido/apagado tecla programable para activar los lmites. Ser la presentacin del nmero a verde si la medida es pasar o rojo si la medicin est fallando. La palabra Pasar o No tambin se mostrar en entre el logartmica y visualizacin lineal de windows. Captulo 6 alta precisin poder Meter

6-3
Mostrar poder relativo Paso 21. Prensa el Amplitud clave. Paso 22. Con la entrada de nivel deseado poder de base en el sensor, pulse el Rel tecla programable de. La se mostrar el rea de mensajes Relativa A y la lectura de poder mostrar 0 dB y 100%. Si la medicin de una seal de 10 dBm con el Rel clave seleccionados, una cada a 7 dBm mostrar 3dB y 50%. La medida de ahorro Paso 23. Prensa el Guardar visualizacin clave. Paso 24. Utilice las teclas para introducir un nombre de seguimiento. Transferencia de datos a mano herramientas de Software El maestro de sitio tiene slo un puerto serie, por lo que no es posible comunicarse con ambos el Sensor de PSN50 y un PC con herramientas de Software de mano (HHST) al mismo tiempo. Por lo tanto, slo las mediciones guardadas pueden verse en HHST cuando se utiliza la PSN50. Para ver guarda las mediciones, desconecte el cable serial de la PSN50 y conectarlo a la serie Puerto del PC que ejecuta HHST. Consulte el captulo de herramientas de Software de mano en este manual para obtener ms informacin.

6-4
Captulo 6 alta precisin poder Meter

Captulo 7 Herramientas de Software de computadora de mano


Introduccin
Este captulo proporciona una descripcin de las herramientas de Software de mano Anritsu (HHST) programa. Herramientas de Software de computadora de mano es un programa de Windows 95/98/NT4/2000/ME/XP/Vista para transferir miden trazas, junto con los marcadores y las lneas de lmite, a la pantalla del PC. El funcin de ayuda del programa proporciona instrucciones en pantalla en pantalla modificacin, superposicin de seguimiento, carga y descarga de huellas y la impresin de trama mltiples. Herramientas de Software de Master (MST) ahora funciona con la S331D del sitio maestro. Se recomiendan a los usuarios migren a MST. Esta plataforma tiene numerosos ventajas de productividad sobre HHST y todas las mejoras del producto futuro ser hecho a travs de MST. Para obtener ms informacin sobre el MST, consulte el captulo 8.

Caractersticas
Herramientas de mano de Software proporciona las siguientes caractersticas: Descargar huellas guardados en la memoria de instrumento a la PC para almacenamiento y anlisis Cargar rastros del PC en la memoria del instrumento Superposicin de trazado permite la visualizacin de tres parcelas simultneamente Capacidad de guardar capturados solares como archivos de datos (formato de archivo .dat) o registros que representan informacin del sitio en un archivo de base de datos

Capacidad

de exportar los datos de trama como archivos de texto para su uso en una hoja de clculo (formato de archivo .txt) Capacidad de guardar capturados solares como archivos grficos (formato de archivo .wmf) Capacidad para acercar o alejar a analizar una regin particular de la parcela Capacidad para modificar las propiedades de trazado Capacidad de salida de parcelas una impresora para registros de copia impresa Capturar el trazado actual de la unidad Crear cables personalizados para cargarse en el instrumento Crear nuevas normas de seal para cargarse en el instrumento Crear nueva onda cargarse el instrumento

7-1

Requisitos del sistema


El programa de mano herramientas de Software se ejecuta en cualquier equipo que ejecute Windows 95/98/NT4/2000/ME/XP/Vista. Recomendaciones y requisitos mnimos son: Microprocesador Intel Pentium 100 MHz (se recomienda Pentium II 350 MHz o superior) 16 MB de RAM (64 MB o sobre recomendado) Unidad de disco duro con aproximadamente 15 MB de espacio disponible (adicionales 20 MB de espacio libre para el almacenamiento de tramas capturadas se recomienda). Serie (COM) A puerto o un puerto USB y el cable de adaptador de alimentacin USB para la comunicacin con el instrumento Nota: Se recomienda que los usuarios de Windows NT 4.0 instalan servicio de NT 4.0 Pack 3 (SP3) o posterior. Adems, Windows 2000 (Service Pack 1 o superior) y Windows Permito requieren la instalacin de los Service Pack ms reciente. Pngase en contacto con Microsoft Corporation para obtener ms informacin sobre cmo obtener e instalar servicio paquetes.

Instalacin
Para instalar el programa de mano herramientas de Software: Paso 1. Inserte el disco de Anritsu mano herramientas de Software en la unidad de CD-ROM. Paso 2. Desde el men Inicio de Windows, seleccione Ejecutar. Paso 3. Tipo: X:\setup.exe donde x es la letra de la unidad de CD-ROM. Paso4. Cuando se le solicite, pulse el Entrar tecla para aceptar el directorio c:\Archivos Herramientas de Software de programa\ y la instalacin comenzar. El Lame.doc el archivo en el disco proporciona informacin actualizada sobre el programa y el Funcin de ayuda proporciona informacin detallada de funcionamiento.

7-2
Captulo 7 herramientas de Software de computadora de mano

Configuracin de puerto de comunicacin


Las herramientas de Software de mano se comunica con el instrumento a travs de una serie estndar Puerto COM en el PC. Establecer la velocidad en baudios del puerto COM a 115200. Paso 1. Seleccione Inicio, Programas y seleccione Herramientas de software. Paso 2. Cuando se ha cargado el programa, seleccione Configuracin, Comunicacin. Paso 3. Seleccione el puerto COM de PC adecuado y transferencia en baudios para el sistema, y haga clic en Aceptar. (Para el opcional Adaptador de Cable USB (551-1691) establece el COM puerto COM 4, y la velocidad en baudios a 38400.) Captulo 7 herramientas de Software de computadora de mano

7-3
Figura 7-1. Cuadro de dilogo Configuracin de comunicacin

Instalacin del Cable de interfaz


Comunicacin entre el instrumento y el PC se lleva a cabo sobre un serie de mdem nulo cable suministrado con el instrumento (Anritsu parte nmero 800-441 y USB opcional para adaptador serie, parte nmero 551-1691, si es necesario).

Paso 1. Instale el cable de interfaz serial de mdem nulo para el conector de interfaz serie RS232 en el panel de conectores de prueba. Paso 2. Conectar el otro extremo del cable de interfaz serial para el puerto COM adecuado conector en el PC. Paso 3. Encienda el instrumento y el PC.

7-4
Captulo 7 herramientas de Software de computadora de mano
MANTENGA EJECUTAR INICIO CAL Automtico ESCALA GUARDAR EL PROGRAMA DE INSTALACIN RECORDAR EL PROGRAMA DE INSTALACIN MARCADOR DE LMITE GUARDAR VISUALIZACIN RECORDAR VISUALIZACIN IMPRIMIR

MODO FREQ/DIST AMPLITUD MEAS/DISP. SYS


ENTRAR CLARO ESCAPE ON OFF

/ 12 4 56 78 90 3
+ .

S332D

PUERTO COM INTERFAZ SERIAL

Figura 7-2. Conexin del Cable serie

Utilizando herramientas de Software de computadora de mano


Seleccione Inicio, Programas y seleccione Herramientas de software.

Descarga de trazas
Huellas que pueden descargarse desde el instrumento se agrupan por la fecha en que se se han guardado. Adems estn organizados en orden cronolgico para cada fecha, con la ms antigua seguimiento en la parte superior de la lista. Cada anuncio de seguimiento muestra el tipo de nombre y medicin de seguimiento para esa traza. Tipos de medicin disponibles son:
Volver a prdida de insercin de prdida Ganancia de insercin de cables de acero Cable de Monitor de potencia de prdida DTF (distancia a fallas)

Nota: No todas las selecciones de aplicarn a cada instrumento Anritsu organizador.

Captura de la trama para el PC


Para abrir los mens de captura de la trama, seleccione el icono de captura en la barra de botones o seleccione el Capturar men de la barra de men desplegable Seleccione Captura de pantalla Descargar huellas en el PC. Seleccione una carpeta o trazos individuales dentro de una carpeta, para ser descargado en el PC. Las huellas aparecer en la pantalla del PC como se descargan. Herramientas de Software cuando se comunica con el instrumento, Remoto se mostrar a la izquierda del grfico.

Carga de trama del instrumento


Abrir un complot para cargarse en el instrumento. Se pueden modificar propiedades de trazado en el PC antes de se carga si lo desea. Seleccione el Capturar men de la barra de men desplegable Seleccione Cargar el trazado actual para cargar la trama en el instrumento. La trama ser almacenados en la memoria no voltil de instrumento con la fecha y hora que la trama se ha guardado. La traza cargada puede verse en el instrumento presionando la recordar Visualizacin botn en el teclado numrico del instrumento. Captulo 7 herramientas de Software de computadora de mano

7-5
Propiedades de trazado

Despus de Descargar, se pueden modificar ciertas propiedades de trama y la informacin. Seleccione el trazado Icono de propiedades o informacin de parcela. Propiedades de trazado que se pueden modificar incluyen: Ttulos de grfico Modo de visualizacin Escala/lmite Marcadores Varios (parmetros de visualizacin de trama) Ttulos de grfico Despus de descargar la trama, el Ttulo principal puede ser modificado para reflejar el nombre del sitio o de otros informacin descriptiva. El Ttulo Sub campo puede utilizarse para describir las caractersticas especficas de la medicin y configuracin. Escala/lmite Puede modificar la escala del trazado aparece para ayudar a analizar si cumple con la trama criterios de aprobado/suspenso. El submen escala/lmite activa las opciones para introducir manualmente la escala lmites, o para utilizar el modo de escala automtica. Manual ajuste establece los lmites superiores e inferiores de la pantalla en el Submen de escala/lmite. Escala automtica ajusta automticamente la escala de medida mxima y mnima lecturas. Lnea lmite desactiva todas las lneas de lmite. Lnea de lmite puede activarse para ayudar a identificar errores. Varios segmentos lneas de lmite puede activarse para establecer lmites diferentes dentro de la misma medicin mostrar para los requisitos de la especificacin. Marcadores M1 de marcadores a travs de M6 pueden activarse desde el men de propiedades de trazado. Los seis marcadores activos pueden mostrarse en la parcela para ayudar a identificar las fallas de la lnea datos de barrido.

7-6
Captulo 7 herramientas de Software de computadora de mano Misc. La ficha varias permite ajustar el ancho de la lnea de trama/lmite, la configuracin de la Trama de pie de pgina y el formato de fecha. Trama/lmite de ancho de lnea puede utilizarse cuando la preparacin de informes de la compaa, servicio proveedores y operadores de red donde los datos de seguimiento deben ser visibles y legible para la documentacin. La densidad de la lnea de la traza se puede establecer en Normal (Lnea fina) o Lnea gruesa para que los datos que aparecen fcilmente cuando son copias hecho. Parcela de pie de pgina permite la seleccin de la informacin que se mostrar en la pantalla de seguimiento. Las selecciones son: Fecha y hora Impedancia Modelo y nmero de serie Las mediciones Sesgo Tee Parmetros DTF Formato de fecha: dd/mm/yyy dd/mm/aaaa aaaa/mm/dd Nota: Aunque se muestran todas las posibles selecciones, algunas de estas selecciones aplicar slo para modelos especficos de mano Anritsu celebraron instrumentos.

Superposicin de trazado o superposicin de trazado


Superposicin de seguimiento se activa mediante el icono de funcin de ratn. Haga clic en la funcin de ratn icono para alternar. Alternar este icono cambia la funcin de ratn entre el marcador, lmite/Zoom y superposicin de trazado. Para superponer dos parcelas, pulsar y arrastrar de una parcela a la otra parcela. La pantalla final ser las dos parcelas superponer el uno al otro. Consulte las herramientas de Software de computadora de mano Ayuda funcin para obtener ms informacin sobre los pasos es necesario realizar un seguimiento de superposicin.

Trazas de ahorro
Una vez que las parcelas son capturadas al PC pueden guardarse como archivos individuales o como un bloque de archivos en una base de datos. Guardar un trazado como un metarchivo de Windows o a una hoja de clculo Parcelas pueden guardarse como un metarchivo de Windows (.wmf), un archivo .dat de herramientas de Software de mano, un archivo de texto (.txt) o una base de datos MDB. Metarchivo podr importarse en programas de grficos y puede importar el archivo de texto en una hoja de clculo. Los archivos .dat y .mdb se utilizan exclusivamente las herramientas de Software de mano. Para guardar un trazado como un metarchivo de Windows, haga clic en el Archivo men y seleccione Exportar a Metarchivo desde el men desplegable. Una vez que la traza se guarda como un metarchivo, pueden copiarse y transferidos a otras aplicaciones como una imagen o un archivo grfico. Captulo 7 herramientas de Software de computadora de mano

7-7
Para copiar un metarchivo: Paso 1. Seleccione la traza a copiarse con el cursor del ratn. Paso 2. Seleccione Editar y entonces Copia. El archivo se copia en el Portapapeles, o seleccione archivo y entonces Exportar a un metarchivo de Windows. Paso 3. Abrir la aplicacin de destino (Microsoft Word, etc.). Paso4. Seleccione Editar y entonces Pegar. Se insertar el archivo como un archivo grfico o un Mapa de bits. Guardar un grfico a una hoja de clculo Parcelas pueden guardarse como un archivo de texto (.txt) que, a continuacin, se puede importar en una hoja de clculo. Para guardar un trazado como un archivo de texto: Paso 1. Seleccione la traza a copiarse con el cursor del ratn. Paso 2. Haga clic en el Archivo men y seleccione Exportar a archivo de texto para una hoja de clculo desde el men desplegable. Paso 3. Guarde el archivo en un directorio local. Paso4. Salir del programa de herramientas de Software de computadora de mano y abra la aplicacin de la hoja de clculo. Step5. Importar el archivo .txt en el programa de hoja de clculo.

Creacin de una base de datos


Una traza o un bloque de huellas puede transferirse desde el instrumento a la PC. Un independiente base de datos se puede crear para cada sitio celular. El nombre del sitio puede utilizarse como la base de datos nombre. Paso 1. Seleccione el Archivo men y seleccione la Base de datos. Paso 2. Abrir una base de datos existente o crear una nueva base de datos con un nombre de archivo descriptivo representa el nombre del sitio.

Una vez que se ha creado la base de datos, pueden guardar archivos y puede agregar la informacin del sitio, como parcela descripcin, fecha y hora, operador, registro y seguimiento descripcin nmero y perodo de sesiones (tipo de transmisor, etc.). Parcelas individuales se etiqueta con el nombre de base de datos del sitio. Cada registro tiene su propia trama Descripcin y tipo de medida.

Formatos de impresin
Uno a varias parcelas por pgina puede configurarse en el formato de impresin en mano de Software Herramientas. Puede cambiar la orientacin de cmo se imprimen las parcelas en la pgina de vertical a horizontal.

7-8
Captulo 7 herramientas de Software de computadora de mano

Lista de cable
Una lista personalizada de cable puede crear en herramientas de Software y cargada para el sitio maestro. Algunos cables estndar de 1000 MHz MHz 2000 y 2500 MHz se almacenan en el sitio principal y son enumerados en el Apndice A de esta gua del usuario. La lista de cable contiene informacin vital como la velocidad de propagacin (Vp) y de insercin prdida (dB/m o dB/ft). Estos parmetros son importantes al identificar las fallas y discontinuidades de lneas de transmisin. Nota: Los valores de la lista de cable se toman de las especificaciones de los fabricantes. Sistemas de comunicaciones digitales complejos pueden requerir ajustes a la atenuacin valores en las frecuencias ms altas. Pngase en contacto con el fabricante para el adecuado prdidas de cable. El Editor de Cable est especficamente diseado para proporcionar a contratistas y proveedores de servicios de red operadores con una lista de tipos de cable que se adaptan a su uso. Para abrir el Editor de Cable, seleccione el Herramientas men y seleccione Editor de cable. Para abrir un archivo de lista de cable existente, seleccione Archivo y Abierto. Seleccione la lista de cable deseado y pulse Entrar.

Crear una lista personalizada de Cable


Para crear una lista personalizada de cable: Paso 1. Seleccione el Archivo men y seleccione Nuevo. Paso 2. Escriba o cortar y pegar los tipos de cable y las especificaciones de los cables deseado.

Cargar una lista de Cable


Despus de la lista personalizada de cable se ha creado en herramientas de Software de computadora de mano, puede cargarse en el Sitio maestro. Debe estar conectado el cable de mdem nulo de comunicacin serial del sitio Maestro de la PC. En el Editor de Cable, seleccione Herramientas y Cargar la lista de Cable. El software confirmar la carga con el mensaje "Carga completa"cuando haya terminado la operacin.

Consultar la lista principal de sitio de Cable


Lista de Cable de consulta permite al usuario comprobar y revise el contenido de la lista de cable personalizado en el sitio maestro. En el Editor de Cable, seleccione Herramientas y Lista de Cable de consulta. El software Descarga el cable lista desde el sitio maestro al PC.

DTF parcelas
Herramientas de Software de computadora de mano puede convertir prdida volver en parcelas de dominio de la frecuencia (Freq-RL) y cables de acero en el dominio de la frecuencia (Freq-SWR) de parcelas parcelas DTF. Captulo 7 herramientas de Software de computadora de mano

7-9

Para convertir de dominio de la frecuencia a distancia a falla, siga estos pasos: Paso 1. Capturar una parcela o cargar un trazado guardado anteriormente. Paso 2. Haga clic en el Distancia a fallas botn en la barra de herramientas (o elija Distancia a fallas de la Herramientas men de). Se abrir un cuadro de dilogo permite especificar los parmetros de cable, empezar a distancia y dejar de distancia. Puede seleccionar el tipo de cable de la lista desplegable. Seleccione un cable de la lista automticamente establece la propagacin prdida de velocidad y de insercin. Para introducir manualmente la constante dielctrica e insercin prdida, seleccione el cable Custom escriba desde la parte superior de la lista. Haga clic en OK cuando terminado. Abrir una nueva ventana que muestra la trama convertida. Paso 3. El cursor para leer los valores de uso se muestra en la bandeja de la parte inferior de la pantalla del PC, en cada punto a lo largo de la traza DTF. Maximizar la ventana de la parcela para la mejor resolucin de cursor. Notas: Las unidades de distancia (metros o pies) pueden cambiarse mediante la seleccin predeterminada Trazar la configuracin en el men de configuracin. La entrada de distancia de parada debe ser menor o igual al mximo ONU-alias gama (D-Max) y la distancia inicial deben ser menor que la distancia de parada.

Carta de Smith
La Carta de Smith es un formato grfico utilizado para el anlisis de la impedancia de lneas de transmisin. Puede ser una herramienta til para ajustar un sistema de antena. Herramientas de Software de computadora de mano puede convertir a los siguientes tipos de parcelas a Smith de grficos: Devolver la prdida (dominio de la frecuencia) VSWR (dominio de la frecuencia) Para convertir un trazado en un grfico de Smith: Paso 1. Capturar una parcela o cargar una parcela de prdida de volver o VSWR guardada anteriormente. Paso 2. Haga clic en el Carta de Smith botn en la barra de herramientas (o elija convertir a Carta de Smith de la Herramientas men de). Abrir una nueva ventana que muestra la trama en la Carta de Smith formulario. Paso 3. Para leer los valores de un grfico de Smith, mueva el puntero del ratn sobre un punto de datos. Cuando el puntero del ratn se convierte en una mano, pulse con el botn izquierdo. A ventana emergente aparecer con diversos datos de medicin.

7-10
Captulo 7 herramientas de Software de computadora de mano

Editor de estndares de seal


El Editor de las normas de la seal es una aplicacin de software para ver, editar y crear seal archivos de normas. Seleccione una entrada de seal estndar de la lista para activarla. El Editor de las normas de la seal puede: _ Crear nuevos archivos de estndares de seal _ Ver y editar las definiciones estndar de seal _ Copiar y pegar la seal definiciones estndar _ Recuperar el archivo de normas de la seal de una unidad de prueba _ Almacn de un archivo de normas de seal actualizada en la unidad de prueba _ Generar un informe del archivo de normas de seal

Crear un nuevo archivo de normas de seal


Para crear un nuevo archivo de normas de seal, seleccione Nuevo archivo de normas de seal de la Archivo men desplegable. Se mostrar un archivo de normas de seal vaca. Para agregar un nivel de seal, Seleccione Aadir seal estndar de la Editar men. Para agregar un estndar existente de la seal desde un archivo de normas de seal diferente, utilice la Cortar,
Copia y Pegar iconos, o seleccione Cortar, Copia y Pegar de la Editar men.

Edicin de un nivel de seal


Una definicin estndar de la seal puede cambiarse mediante la edicin del nombre y los parmetros. El activo

lnea de la norma de seal actual se muestra en el cuadro de entrada de texto en la barra de herramientas principal. Si esta casilla est desactivada, no se puede editar el nivel de seal seleccionada. Todos los cambios son temporales hasta que guarda como un archivo de disco. Para guardar el archivo de normas de seal en el PC local, seleccione Guardar de la Archivo men.

Cortar, copiar y pegar


Uso la Cortar, Copia y Pegar iconos, o seleccione Cortar, Copia y Pegar de la Editar men para Aadir, copiar o eliminar las normas de la seal. Corte mueve el estndar de seal actualmente seleccionado en el Portapapeles y el estndar de la seal se elimina de la lista de las normas de la seal. Si se guarda el archivo de normas de la seal, el corte de seal estndar ser permanately eliminado de la lista. Copia pone una copia de la norma de seal en el Portapapeles, pero no lo elimina de la lista actualizada de las normas de la seal. Pegar copia un estndar de la seal desde el Portapapeles en la lista actual de las normas de la seal. Captulo 7 herramientas de Software de computadora de mano

7-11
Recuperar archivos de estndares de seal
Administrador de conexin debe estar conectado a una unidad de prueba antes de recuperar un nivel de seal archivo. Una conexin activa se indica en la barra de estado en la esquina inferior derecha de la aplicacin ventana. Para recuperar un archivo de normas de seal, seleccione Seal de recuperar las normas de la Conexin men o utilice el icono de acceso directo en la barra de botones. Los datos recuperados de las normas de la seal ser Reemplazar todos los datos existentes de normas de seal en el Editor de niveles de seal. Para almacenar el actual Normas de seal de datos local, seleccione Guardar de la Archivo men y guardar la seal actual Archivo de normas antes de recuperar el archivo de normas de seal de otro de una unidad de prueba.

Almacenar archivos de estndares de seal


Para cargar el archivo de normas de seal para una unidad de prueba, seleccione Cargar las normas de la seal de la Conexin men de, o pulse el icono de acceso directo en la barra de botones. Esto cargar el actual Archivo de normas a la unidad de prueba, sobrescribiendo los datos ya estn en la unidad de prueba de seal.

Informes de las normas de la seal


Se genera un informe de normas de seal seleccionando el Informe funcin de la Archivo men. Un informe de las normas de la seal es un archivo HTML y se puede abrir en el valor predeterminado navegador de la PC, donde se pueden imprimir si lo desea.

7-12
Captulo 7 herramientas de Software de computadora de mano

Captulo 8 Herramientas de Software de Master


Introduccin
Este captulo proporciona una introduccin a las herramientas Anritsu de Software Master (MST) programa. Los usuarios del programa heredados de herramientas de Software de mano (HHST) son fuertemente alienta a migrar a la nueva plataforma de MST. Esta nueva plataforma tiene numerosos productividad ventajas sobre HHST, como se describe a continuacin en la lista de funciones. Todo futuro producto mejoras se llevar a cabo a travs de MST. Herramientas de Software de maestro es un conjunto de programas de Microsoft Windows para la transferencia de guardado

medidas, junto con los marcadores y las lneas de lmite, a una pantalla de PC. Los programas proporcionan la capacidad de modificar los parmetros de visualizacin, superponer mltiples huellas, carga y descarga huellas, rastros de impresin con impresoras locales o en red, creacin o modificarn archivos de idioma, editar el cable y seal estndar listas y convertir archivos .dat al nuevo formato de .vna. Herramientas de Software de maestro requiere Windows 2000 (Service Pack 4 o superior), Windows XP (Service Pack 2 o superior), o Windows VISTA. MST no funciona en versiones anteriores el sistema operativo de Microsoft Windows como el programa se basa en Microsoft.NET Marco.

Caractersticas clave de herramientas de Software de Master


_ Importaciones

deherramienta de conversin de archivos DAT: esta utilidad.Archivos DAT del Software mano Herramientas y se convierte en el nuevo formato de MST. El.Archivo DAT no cambia por el proceso. Una vez convertido, estos nuevos archivos pueden abrirse y editarse con el Editor de medicin. _ Cable Editor: esta aplicacin permite eliminar, modificar y aadir nuevos cables a la memoria del instrumento. _ Seal estndar Editor: si existe una norma que no est incluida en el instrumento, el MST puede modificar, editar y agregar la lista estndar de la seal. _ Actualizacin de producto: esta caracterstica mantiene informado del firmware ms reciente del instrumento Versin. _ Codeloader integrada sin necesidad de instalar un programa separado para actualizar el instrumento Firmware. Todo puede abordarse con el MST. _ Trace cambiar el nombre de utilidad: permite cambiar el nombre de cientos de huellas en un par de minutos. Se trata de un ahorro de tiempo real para personas que gastar mucho tiempo cambiar el nombre de huellas. _ Editar grupo: si tiene una carpeta con cientos de huellas y olvid encender la marcadores o lneas de lmite, puede utilizar la herramienta de edicin de grupo para copiar los marcadores y limitar la lnea de un seguimiento a todas las trazas en una carpeta especfica. _ Avanzado editor de lnea de lmite: mscaras de lnea lmite complejo de crear y cargar a la instrumento. _ Administracin de archivos de Windows estndar: simplificar el proceso de descarga, arrastrar, y soltar archivos.

8-1
_ Editor

de idiomas: esta utilidad permite aadir o modificar tablas de lenguaje existente. Idiomas disponibles para la seleccin son ingls, francs, alemn, espaol, italiano, Japons, chino y coreano. Todos estos idiomas excepto en ingls pueden editarse. Hasta dos ms idiomas personalizados se pueden cargar mediante esta utilidad. _ Archivos AVI: crear archivos de vdeo de su medicin espectrograma favorito.

8-2
Captulo 8 herramientas de Software de computadora de mano
Figura 8-1. Medicin de VNA utilizando la tabla de marcador Figura 8-2. Utilidad de cambiar el nombre de seguimiento le permite cambiar el nombre de cientos de huellas en minutos

Nota: El nuevo firmware no es compatible con herramientas de Software de Master versin 1.25 o ms aos. Asegurar que tienes la mxima funcionalidad mediante la actualizacin de su maestro Herramientas de software a la versin ms reciente. Captulo 8 herramientas de Software de computadora de mano

8-3
Figura 8-4. Herramienta de conversin de archivos DAT utilizada para convertir las trazas existentes de antena y Cable & SPA al MST

Figura 8-3. Herramientas de actualizacin de producto de MST se utiliza para descargar el software y firmware ms recientes

Requisitos mnimos del sistema


_ Microsoft

Windows 2000 (Service Pack 4 o superior), Windows XP (Service Pack 2 o arriba), o Windows VISTA _ Microsoft.NET Framework, versin 2.0 _ Microprocesador Intel Pentium 233 MHz (Pentium III 350 MHz o mejor reanud) _ 128 MB de RAM disponible (256 MB recomendado por encima o) _ Unidad de disco duro con aproximadamente 80 MB de espacio disponible (MB 80 adicional gratis espacio para el almacenamiento de tramas capturadas se recomienda). _ Puerto de A USB (USB 1.2 requerido, USB 2.0 recomendado) o una Ethernet 10/100 Base-T conexin para la comunicacin con el instrumento

8-4
Captulo 8 herramientas de Software de computadora de mano

Apndice A Ventanas
Introduccin
El Frecuencia/DIST men (pgina 2-11) se proporciona para establecer la propagacin relativa y la prdida de cable velocidad dede cable coaxial. El ventana clave abre un men de ventanas FFT tipos para el clculo de DTF. El requisito terico inversa FFT es para que los datos que se extienden desde cero frecuencia a infinito. Los lbulos laterales aparecen alrededor de una discontinuidad debido al hecho de que se corta el espectro con una frecuencia finita. Ventanas reduce los lbulos laterales por suaviza las transiciones ntidas al principio y al final del barrido de frecuencia. Reducir los lbulos laterales el lbulo principal ampla reduciendo la resolucin. En situaciones donde puede haber una pequea discontinuidad cerca a una gran reduccin de lbulo lateral deben utilizarse la ventanas. Cuando la resolucin de la distancia es crtica pueden reducirse ventanas.

Ejemplos
Los tipos de ventanas en orden creciente reduccin de lbulo lateral son: rectangular, nominal lbulo lateral, lbulo lateral baja y lbulo lateral mnimo. A-1 a-4 cifras muestran ejemplos de los tipos de ventanas.

A-1
____ ___________________ __ ___ ___ ___ ___ __ __ __ __ ___ _______________ _________________

Figura a-1. Ejemplo de ventanas rectangulares

A-2
Apndice a ventanas
_________________ __________ ____ _________ __ ___ ___ ___

___ __ __ __ __ ___ _______________

Figura A-2. Ejemplo de ventanas del lbulo de lado nominal


_________________ __________ ____ _________ __ ___ ___ ___ ___ __ __ __ __ ___ _______________

Figura A-3. Ejemplo de ventanas de lbulo lateral baja

A-3
Apndice a ventanas
_________________ ___________________ ____ __ ___ ___ ___ ___ __ __ __ __ ___ _______________

Figura A-4. Ejemplo de ventanas del lbulo de lado mnimo

ndice
A
accesorios.............. 1-2, 1-4

B
battery . . . . . . . . . . . . . . . . . . 2-23 brillo................. 3-13

C
prdida de cable serio 4-2, 4-5 calibracin.............. 1-10, 3-2 case. . . . . . . . . . . . . . . . . . . . 3-15 clock . . . . . . . . . . . . . . . . . . . 2-14 conectores................. 2-1 CW. . . . . . . . . . . . . . . . . . . . . 4-3

D
formato de fecha............ 2-14 - 2-15 DTF . . . . . . . 2-11, 3-8, 4-2, 4-7, 7-5, 7-9 DTFAid. . . . . . . . . . . . . . . 2-11, 3-8

E
mensajes de error.............. 2-19 ESD . . . . . . . . . . . . . . . . . . . 1-11

F
FFT . . . . . . . . . . . . . . . . . . . . A-1 FlexCal. . . . . . . . . . . . . . . 2-14, 22-2 frecuencia................. 2-11 rango de frecuencia.............. 1-1

G
puesta a tierra................. 2-1

H
hard keys. . . . . . . . . . . . . . . . . . 2-5 hold . . . . . . . . . . . . . . . . . 2-7, 2-17

I
InstaCal............ 1-11, 21-2, 3-2

K
claves hard . . . . . . . . . . . . . . . . . 2-5 soft . . . . . . . . . . . . . . . . . . 2-8

L
idioma........... 2-14 - 2-15, 3-11 limits . . . . . . . . . . . . . . . . 2-13, 3-12 barrido de lnea................. 4-1

M
mantenimiento serio 1-10 markers . . . . . . . . . . . . . . . 3-11, 7-6 las mediciones cable y antena.......... 4-1 memory . . . . . . . . . . . . . . . . . . 2-7 metafile . . . . . . . . . . . . . . . . . . 7-7

O
offset. . . . . . . . . . . . . . . . . . . . 3-6 OSL . . . . . . . . . . . . . . . . . 2-14, 3-2

P
superposicin de trazado serio . 7-7 indicador de alimentacin.... 2-23 medidor de energa alta precisin.... 1-2, 1-8, 22-2, 6-1 monitor de potencia.... 1-2, 1-8, 2-2, 2-16, 5-1 printers . . . . . . . . . . . . . . . . . . 3-14 velocidad de propagacin........... 2-11

ndice-1
R
resolucin................. 4-8 volver a prdida............... 4-2, 4-9 RS232. . . . . . . . . . . . . . . . . 2-2, 7-4

S
scale . . . . . . . . . . . . . . . . . . . . 3-8 autocomprobacin...... 2-14 - 2-15, 2-18, 2-24, 3-1 interfaz serie serio 7-4 Smith grfico... 1-2, 7-10 soft keys . . . . . . . . . . . . . . . . . . 2-8 Herramientas de software.............. 7-1 Especificaciones serio 1-7 hoja de clculo serio . 7-1 static . . . . . . . . . . . . . . . . . . . 1-11 SWR . . . . . . . . . 20-2, 3-8, 4-2, 4-7, 7-5 symbols. . . . . . . . . . . . . . . . . . 2-17

T
superposicin de seguimiento apropiadas... 7-1, 7-7 Trigger

solo barrido... 2-7

U
units . . . . . . . . . . . . . . . . . . . 3-11 USB . . . . . . . . . . . . . . . . . . . . 7-2

V
verificacin serio . 1-11

W
ventanas... 2-11, A-1 Windows............ 1-2, 7-1-7-2

ndice-2

You might also like