Voltage Monitoring Current Monitoring Mains Monitoring Isolation Monitoring Thermo Protection Relay
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
111
KAT 2008
Monitoring Relays
Monitoring Relays
Co nta c Se rie s t et
Voltage Monitoring
Undervoltage Monitor Undervoltage Monitor Overvoltage and Undervoltage Monitor DC Voltage Monitor AC or DC Voltage Monitor Precision DC Voltage Monitor RMS Precision AC/DC Voltage Monitor
So ck
DIN 35
SSU7...
Current Monitoring
Overvoltage Monitor Undervoltage Monitor Overvoltage and Undervoltage Monitor Current Transformer DC Current Monitor (200 mA) DC Current Monitor (2 A) DC Current Monitor (6A) AC or DC Current Monitor
8 A 124
Mains Monitoring
Three-phase Monitor (50 Hz) Three-phase Monitor (50 Hz) Three-phase Monitor (60 Hz) Phase-sequence Monitor
Isolation Monitoring
Isolation Monitor
ESU-D2
DIN 35
5 A 130 5A
TSR19
5A 132 5A
112
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Pa ge
Monitoring Relays
Voltage Monitoring
4
V
V V
DIN
11
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
113
KAT 2008
Monitoring Relays
V
and otheres: www.comat.ch
Undervoltage Monitor
MV 52 (50Hz) MV 62 (60Hz)
al ok 12 12
A2
A1
L N
13mm
MV52 (50Hz), MV62 (60Hz)
U SET (V)
supply
14 11 12
gn ye
VA
t t
gn
ok
fail rd alarm
al
rd
The MV52 (50Hz) or MV62 (60Hz) protects control systems, contactors and motors during undervoltage against thermal overload and malfunctions. The monitoring can be set precisely in volts from U N 30% up to U N. The switching off or on again follows delayed by 0,1/0,5 or 1second. 2 LEDs show the definite monitoring status.
ok
V Setting range Hysteresis t (fail-al-ok) Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C
BS13-K BS13-G
(incl.paper)
TS35
45
90
Order-Nr.
11
14
50 Hz
11 44 13
60 Hz
MV62 /AC120 V
BS13-G BS13-K
114
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
V
and otheres: www.comat.ch
MV 53
+ 0%
230V 115 V
236V 118 V
241V 121V
247V 124 V
253V 127 V
258V 129 V
265V 132 V
270V 135 V
al
ok
A2 A2 A1
230V 115 V 219 V 109 V 207V 103 V 195 V 97V 184 V 92V 173 V 86V 161V 80V 150 V 74V
L N
V O1 V O2 V NOM V U2 V U1
HYST.
HYST.
tO
ok al
fail rd
tR
ok
tO
tR
The MV53 (50/60Hz) protects single phase consumers in AC networks from over- and undervoltage. Overvoltage and undervoltage thresholds can be set independently in percentage of the nominal voltage using two DIP-switches (see diagram above). Using a potentiometer allows setting an alarm delay of 25ms...2,5s. A two-colored LED shows the definite monitoring status.
11
supply
14 12
al
gn
ok
ye
alarm
4
V Setting range overvoltage Setting range undervoltage Hysteresis t O Alarm delay t R Reset time Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C
987
65
TS35
90
Order-Nr.
50/60 Hz
70
22,5
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
115
KAT 2008
Monitoring Relays
MV53
12 11 14
32
10
V
and otheres: www.comat.ch
DC Voltage Monitor
CT 524
Socket C12B0
Relay C32/DC24V
Type CT524.2/DC24V
Module CT524/DC24V
CT524
2 1
supply
9 8 7 5 3 4
2 CT B1 A1
10 11
6 V in
1 12 2
MAX
+
R
t R fail
ok al
DC24V
MIN
tR
R
fail ok al
t
Alarm delay t Reset time t R Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C
INT
0,1/0,5/2s 100ms
t
R
tR
t R fail
ok al
6A 250V A 1500VA/...200W 100 x10 6
EXT
tR
R
gn ok ye fail rd
tR
fail ok al
alarm
Accessories
Socket 0-30 V
Socket and Accessories: Page 97
C12 B0
40 V
CT 524.2 / DC24 V
116
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
V
and otheres: www.comat.ch
Voltage Monitoring AC or DC
CUEBU
L N (+) U
AC 15 ...480 V DC 15 ...700 V
Ri 1M
2 4 6
10
8A 250V A
Functions
Up
Hys
CUEBU 15 -700
Monitoring Relay
for AC or DC voltages ranging from AC15...480V, DC15...700V. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[V]
Up
t1
fail ok al M
R
Supply
[V]
Hys
Lo
Lo
t1
fail ok al M Up [V] Lo
4
V
Data at Tamb. = 20 C
R
Supply
Hys
Up / Lo
t1
t1
fail ok al M
t
Alarm delay time t1 Switching current/voltage Switching power AC1 Output contact
R
Supply
gn
ok
ye
fail
rd
alarm
AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55 C /-40...+70 C
Order-Nr.
50/60 Hz
CUEBU15-700 / AC 230 V
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
117
KAT 2008
Monitoring Relays
V
and otheres: www.comat.ch
RL
9 8 7 5 3 4
DC 10-32V
Um
()
L+ N
10 11
6 1 2
35 mm
FAIL OK OK FAIL
supply
t fail
t ok
normal fail delay alarm
11
9 8
ye rd
ok al
meas. alarm
50mA
(+)
gn
ok
9
0 - 210mV 0,1 - 200mV 0,5mV
2
0 - 38V 0,1 - 35V 20mV
5
0 - 157V 40 - 150V 100mV
6
0 - 285V 0*/50 - 270V 0,5V *SSU76
Switching current/voltage
Example of order SSU DC 0-38V/UC24-48V: SSU23/UC24-48V SSU RMS AC/DC 0-200mV/UC110-240V: SSU79/UC110-240V
Attention: P/O numbers of several devices were changed (refer below). Devices are identical. Old number: SSU11/UC110-240V SSU11/UC60-127V SSU11/UC24-48V SSU11/UC12-15V
Socket and Accessories: Page 97
118
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Monitoring Relays
Current Monitoring
4
A
A
DIN
1 1
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
119
KAT 2008
Monitoring Relays
A
and otheres: www.comat.ch
LOAD 2
2
OP JUST LO
IT
Setting ranges
[A]
1x 2x 3x 4x 5x
-05 0,5-6 0,25-3 0,17-2 0,13-1,5 0,1-1,2 -30 2,5-30 1,25-15 0,83-10 0,62-7,5 0,5-6 -60 5-60 2,5-30 1,7-20 1,25-15 1-12
EOCR-AR EUCR-BR
A A tO
supply
tO
tR
1/2
L (+) U B N
al
SCHTZ CONTACTOR
15
18 16
gn ok ye fail rd
ok al
alarm
EOCR-AR / EUCR-BR
1 fail
or
2 fail
= FAIL
The EOCR-AR and the EUCR-BR monitor overcurrent and undercurrent on AC power circuits. One or two current paths can be monitored directly up to 60(75)A, by means of the integrated current loop transformers. The adjustable alarm delay ( t O) and the automatic alarm resetting ( t R) permit universal usage in motor and transformer protection systems, monitoring of electrical heating elements and in the control of pumps, ventilation systems, suction and feed devices. The nominal monitoring range in the 3 types -05/-30/-60 can be altered by multiple looping of the conductor (see schedule above).
al ok
A2 A1 15 16 18
+L
N
t
Alarm delay t O Reset time t R Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C
Order-Nr.
16
10 10
AC
50/60 Hz
UC (AC/DC)
05 30 60
20
05 30 60
A1
15
16
EOCR-AR- ... / AC 230 V EOCR-AR- ... / AC115 V EUCR-BR- ... / AC 230 V EUCR-BR- ... / AC115 V
EOCR-AR- ... / UC 24 V
EUCR-BR- ... / UC 24 V
62
54
120
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
A
and otheres: www.comat.ch
ECR-3D
Setting ranges
-05 -60
L1
L2
[A]
1x
2x
3x
4x
5x
L3
-05 0,5-6,5 0,25 - 3,2 0,17- 2,1 0,13-1,63 0,1-1,3 -60 5 -75 2,5- 38 1,7-25 1,25-18,8 1-15
L1 or L 2 or L 3
0 U
L1+L 2 +L 3 off
A A
tO
supply
tR
tO
tR
R1
1 fail
or
2 fail
or
3 fail
= FAIL
R2
+
R1
al ok
al ok
A2 A1 26 25 28 16 15 18
The adjustable alarm delay ( tO) and the automatic alarm resetting ( tR) permit universal usage in automation and protection techniques. The set values are displayed automatically by setting the respective parameters. Triggered faults remain stored and displayed until reset.
1 2
+L
N
2
( L1) ( L2) ( L 3)
t
Alarm delay t O Reset time t R Switching current/voltage Switch rating Mechanical switching cycles Voltage tolerance AC /UC Power consumption Ambient temperature
0,3 - 30s 1,0 - 120s / 3A 250V A 750VA/...90W 20x10 6 0,8-1,1/1,25 U N 3(5) VA /1,5W 20...+60 C
16
10
10
10
Order-Nr.
21
UC (AC/DC)
A2 A1 26 25 28 16 15 18
30
05 60
71
70
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
121
KAT 2008
Monitoring Relays
dis t you to oduct is ill assis w This pr s t s li prodt specia te successor produc ia ECR-3D ppropr tion. d the a applica r finECR-3D u o y The is for monitoring overcurrent and r tact us on AC t fo onundercurrent c c u o t e t power circuits. sita he t up donof 60(75)A Three current to 60(75) A can be monitored directly ase paths le P by means of the inte-grated current loop transformers.
L UB N
15 25
18 16 28 26
gn ok ye fail rd alarm
R2
Current Transformers
and otheres: www.comat.ch
SRCT-35
Current transformers of the SRCT-35 series transform high AC currents into proportional secondary current in the ratio 10:1 (type -50) up to 100:1 (type -500). With accuracy class 1, coupled with a large power reserve (PN: 2,5VA) and high overload capacity up to 150%, the SRCT-35 is the ideal transformer for general applications and for the use with Comat monitoring relays ..AR, ..BR, ..3D.
10
BEF 1
k
86
35
Direct mounting
Order-Nr.
UC (AC/DC)
FOR M4 38 40 4.3 3
SRCT-35 - ... / 5 A
4,5 50 76 2 65
122
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
A
and otheres: www.comat.ch
DC Current Monitor
(200 mA) (2 A) (6 A)
Socket C12B0
Relay C32/DC24V
Type CT512.2/DC24V
Module CT512/DC24V
CT512,515,516
2 1
supply
9 8 7 5 3 4
2 CT B1 A1
10 11 RL
6
in
1 12 2
MAX
+
R
t R fail
ok al
DC24V
MIN
tR
R
fail ok al
t
Alarm delay t Reset time t R Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C
INT
0,1/0,5/2s 100ms
t
R
tR
t R fail
ok al
6A 250V A 1500VA/...200W 100 x10 6
EXT
tR
R
gn ok ye fail rd
tR
fail ok al
alarm
Accessories
C12 B0
300 mA 3A 7A
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
123
KAT 2008
Monitoring Relays
A
and otheres: www.comat.ch
Current Monitoring AC or DC
CUEBI
L N (+) U
2 4 6
10
8A 250V A
Functions
Up
Hys
CUEBI01-10
Monitoring Relay
for AC or DC currents ranging from 0,1A up to 10A with start-up delay. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[A]
Up
t2
t1
fail ok al M
R
Supply
[A]
Hys
Lo
Lo
t2
t1
fail ok al M Up [A] Lo
R
Supply
Data at Tamb. = 20 C
Hys
Up / Lo
t
Alarm delay time t1 Start-up delay t 2 Switching current/voltage Switching power AC1 Output contact
t2
t1
t1
fail ok al M
R
Supply
gn
ok
ye
fail
rd
alarm
Operation voltage AC50/60Hz Power consumption P max Isolation Temperature: operating / storage
AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55 C /-40...+70 C
Order-Nr.
50/60 Hz
124
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Monitoring Relays
Mains Monitoring
4
3
DIN
11
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
125
KAT 2008
Monitoring Relays
3
and otheres: www.comat.ch
SSU33 (50Hz)
1)
230V ( )
2)
400V ( )
6 A 250 VA 1500 VA/ ...270 W
ok alarm
L1 L2 L3 N 10
1) 2)
<
MIN
U
FIX
>
MAX
1 0,2 - 5 s ok al
t del
2
11 9 2
U, ,
PHASE SEQUENCE
7 4 5
SSU33L
The SSU33 (50Hz) provides comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are monitored: Error signal 1 U (V , V ): Exceeding or dropping below the fixed voltage values Umin/Umax for L1-N or L1-L2 (no differential voltage, phase position or frequency fault). Error signal 2 U, , : One or more of the three voltages, phase positions, phase sequence or the mains frequency are diverging from the required value. Depending on the nature of their occurrence -errors are evaluated cumulatively. Any error is signalled by the red LED and is reported after expiry of the set alarmdelay time ( t del 0,2...5s) via 7-4-5. In the correct status (ok) the green LED is illuminated (4-5 open, 4-7 closed).
3x 230 (400) V
1)
3x 400V
2)
L1 N L2 L3
L1 L2 L3
U
1
U U U U U U
/ Order no.
> 275V
> 480V
< (U min)
2
<160V
20 - 100V 35 - 173V 3-15/3-15Hz SSU33L/AC230V
< 280V
20 - 100V 35 - 173V 3-15/3-15Hz SSU33L/AC400V
Differential range
75
C11A
Socket and Accessories: Page 97
38
126
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
3
and otheres: www.comat.ch
<
N oder or L L3 L2 L1
MIN
MAX
1
t del
2 0,2 - 5 s
ok
al
fail red gn
ok alarm
U, ,
PHASE SEQUENCE
3
4 5 6 3 7 8
E The SSU34 (50Hz) and the SSU36 (60Hz) provide comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are moni-tored: Error signal 1 U (V , V ): Exceeding or dropping below the set voltage values Umin/Umax for L1-N or L1-L3,L (no differential voltage, phase position or frequency fault). Error signal 2 U, , : One or more of the three voltages, phase positions, or the mains frequency are diverging from the required value. Depending on the nature of their occurrence errors are evaluated cumulatively. Error signal 3 : Connection polarity reversal (wrong phase-sequence). Any error is signalled by the red LED "fail" and is reported after expiry of the set alarm-delay time ( t del 0,2...5s) (for error signal 3 undelayed) via 5-6 and 7-8. In the correct status (ok) the green LED is illuminated (5-6 and 7-8 open, 5-4 and 7-2 closed).
50Hz U
1
50Hz
230/400VA 235-275V 410-480V 160-225V 280-390V 20-100V 35-173V 3-15/3-15Hz SSU34 /AC400V
50Hz
290/500VA 300-350V 520-600V 200-280V 350-485V 20-100V 35-173V 3-15/3-15Hz SSU34/AC 500V
60Hz
120/208V A 125-145V 216-250V 85-115V 148-200V 10-50V 17-87V 5-24/3-22Hz SSU36/AC208V
60Hz
265/460V A 270-320V 470-550V 185-260V 322-450V 20-100V 35-173V 4-21/ 3-19Hz SSU36 /AC 460V
60Hz
277/480V A 284-232V 490-575V 194-270V 336-470V 20-100V 35-173V 4-21/ 3-19Hz SSU36 /AC480 V
U U U U U U
/ Order no.
Differential range
Detachable Terminals
105
75
50
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
127
KAT 2008
Monitoring Relays
MAIN
ITORI N O M S
NG
SSU34, SSU36
>
SSU34/36
3
and otheres: www.comat.ch
SSU31
L1 L2 L3
Failure of L2 or L3 cannot be displayed (LED)!
SSU31
U
supply
7 4 5
gn ye
200ms
50ms
gn
ok
fail rd alarm
al
rd
The SSU31 serves as a phase-sequence, three-phase undervoltage and phase failure monitor. The monitoring function helps to ensure the correct rotation direction of pumps, motors and conveyors in mobile devices with connection to different power outlets. The defined undervoltage and phase failure protects against malfunction and damage caused by overheating.
9 8 7 5 3 4
ok
10 11
al
6 1 2 L1 L2 L3
ok
Data at Tamb. = 20 C
Order no.
50/60 Hz
Accessories Relay socket Retaining clip Front mounting C11A HF-24 FZ-23
128
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Monitoring Relays
Isolation Monitoring
DIN
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
129
KAT 2008
Monitoring Relays
Isolation Monitor
and otheres: www.comat.ch
ESU-D2
ESU-D2
30k
supply
t del
t del
tR
1s
tR
1s
4k (Fix)
18 16
(38)
AL2
LEDs
(37)
25
gn
28 26
ok
ok
4k 30k
ye Scale
al
Trend
rd gn ye rd
al
ok meas. alarm
ESU-D2
The ESU-D2 monitors the isolation resistance in non-grounded DC-networks (24-48V D). Two alarm steps (prealarm AL1 and main alarm AL2) are indicated via separate output contacts. Settable alarm delay ( tdel): 0,1-10sec. Displays: bargraph-display of the measured earthing resistance 4...30k (green = ok). Two red LEDs show the ground tendency towards plus (+) or minus ( ). Measuring terminal 5V for the external display of the earthing resistance (0,1V/k ). Test functions: Periodic automatic check, also with key Test. Environmental failures: monitoring of AC-short circuit, overvoltage, ground interruption.
DC 0..52V
E
0,1V/k
V
5V
Pre alarm
AL1
15 16 18
+
Data at Tamb. = 20 C
E2
+
0,1V/k
AL1 AL2
Measuring range Error of measurement Setting range AL1/AL2 Time of error-detection Alarm delay time settable Voltage stability + or /earth
ESU-D2
L E1 25 26 28 37 38
L (+) UB N
AL2
Main alarm
Detachable Terminals
75
Order no.
UC (AC/DC)
ESU-D2 / UC110-240 V ESU-D2 / UC 24-48 V
105
50
130
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Monitoring Relays
4
C
M
1 1
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
131
KAT 2008
Monitoring Relays
C
and otheres: www.comat.ch
TSR19
or
TSR 19
R PTC /
supply
1-3 11-9
gn ok ye
-SWITCH
RESET
gn
ok
fail rd alarm
al
rd
The TSR19 is intended to monitor the temperature of motor coils, generators and transfomers. It detects the temperature of the windings over the change in resistance of the PTC thermistors 1 or the position of the thermo switches 2 . The circuit is designed to detect a break in the continuity of the detection circuit and ground failures. On position PTC, line or sensor fault is also detected. Reset after failure detection: Press reset button or interrupt supply voltage for >200ms.
PTC
Sensor
Thermo Switch
9 8 7 5 3 4
al
A2
ok
A1
10 11
Data at Tamb. = 20 C
6 1 2
Sensor resistance R ok Sensor wire R max Error-detection R fail Sensor supply U 5-7 Sensor supply 5max
100..1800 ; 0..1800 20 R fail >2200 15V / R sens 3mA 5A 250V A 1250VA/...180W 30x10 6
75
Order no.
Accessories
UC(AC/DC)
50/60 Hz
TSR19 / UC 24 -48 V
132
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch