Professional Documents
Culture Documents
, ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME ENGINEERING AND TECHNOLOGY (IJARET)
ISSN 0976 - 6480 (Print) ISSN 0976 - 6499 (Online) Volume 4, Issue 2 March April 2013, pp. 181-190 IAEME: www.iaeme.com/ijaret.asp Journal Impact Factor (2013): 5.8376 (Calculated by GISI) www.jifactor.com
IJARET
IAEME
COMPARISON OF MODULATION TECHNIQUES FOR CASCADED H-BRIDGE TYPE MULTILEVEL CURRENT SOURCE INVERTER
Vinesh Kapadia1 and Dr. Hina Chandwani2 Research Scholar at CHARUSAT, Changa, Gujarat & Associate Prof. Dept of E.C., SNPIT & RC, Umrakh, Bardoli, Gujarat, India 2 Associate Professor, Dept of Electrical Engineering, The M.S.University of Baroda, Vadodara, India
1
ABSTRACT This paper presents a comparison of the different modulation techniques for a single phase five level cascaded h-bridge (CHB) type multilevel current source inverter. Majority of the multilevel inverters are voltage sourced based. The popular carrier based PWM switching techniques for MVSI are the phase shifted and level shifted modulation techniques, the same techniques are tried out for the MCSI along with Selective Harmonic Elimination method using angle control and the results have been presented. Index Terms: APOD, CHB, IPD, Multilevel Current Source Inverter (MCSI), Multilevel Voltage Source Inverter (MVSI), POD, PWM, THD. I. INTRODUCTION MULTILEVEL voltage source inverters are very common and now in wide use. Compared to two-level inverters, multilevel inverters have advantages for higher power applications, including reduced harmonics and reduced switching device voltage and current stresses. The CSIs have some advantages over VSIs such as more stable operating conditions, direct control of the output current, faster dynamic response (in some cases) and easier fault management [1]. In this paper a single phase five level MCSI with symmetric DC current sources is simulated with popular Multilevel Modulation techniques and results are compared with respect to total harmonic distortion (THD).
181
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
II. THE POWER CIRCUIT DIAGRAM Shown below is the circuit for 5 level single phase MCSI along with the switching table TABLE I Switching Combination for the 5 level MCSI Current Amplitude 0 I 2I -I -2I ON Switches S11, S12, S21, S22 S11, S14, S21, S22 S11, S14, S21, S24 S12, S13, S23, S24 S12, S13, S23, S22
Fig-1 Circuit Diagram of the 5 level CHB MCSI The above table shows one of the possible combinations for obtaining the desired current amplitudes.
182
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
III. MODULATION TECHNIQUES A. Angle Control Method (Selective Harmonic Elimination) By proper selection of the firing (displacement angles ) angles it is possible to try and eliminate or say minimize those particular harmonics. The fourier series for unipolar output voltages per half cycle can be expressed as (due to symmetry): vo = ,,,.. sin Bn =
1 1 cos 1,3,5,
Where
The third and fifth harmonics would be eliminated if 1 - cos 3 cos 3 0 1 - cos 5 cos 5 0 [2]-[3] Assuming and initial value of 1 = 0 and calculating in an iterative manner till the results become stable we get;
Initial Values 1st Iteration 2nd Iteration 3rd Iteration 4th Iteration 5th Iteration 6th Iteration
1= 0 , hence 2 = 0.52359 1= 0.28728 2 = 0.64242 1= 0.31366 2 = 0.66478 1= 0.31084 2 = 0.66229 1= 0.31127 2 = 0.66268 1= 0.31121 2 = 0.66262 1= 0.31122 2 = 0.66263
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
Fig-2 Output Current Waveform of the 5 level MCSI with Angle Control Method
Fundamental (50Hz) = 1.108 , THD= 18.22% 12
10 Mag (% of Fundamental)
100
200
300
400
600
700
800
900
1000
Fig-3 Harmonic Spectrum of the 5 level MCSI with Angle Control Method Carrier Based PWM Schemes The carrier-based modulation schemes for multilevel inverters can be generally classified into two categories: phase-shifted and level-shifted modulations. Both the techniques have been applied 1. Phase Shifted Multicarrier Modulation In general, a multilevel inverter with m voltage levels requires (m 1) triangular carriers. In the phase-shifted multicarrier modulation, all the triangular carriers have the same frequency and the same peak-to-peak amplitude, but there is a phase shift between any two adjacent carrier waves, given by cr = 360/(m 1) [4]-[7] B.
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
Fig-5 Output Current Waveform of the 5 level MCSI with Phase Shifted MultiCarrier Modulation
Fundamental (50Hz) = 0.9998 , THD= 2.92% 0.15
Mag (% of Fundamental)
0.1
0.05
100
200
300
400
600
700
800
900
1000
Fig-6 Harmonic Spectrum of the 5 level MCSI with Phase Shifted MultiCarrier Modulation
2. Level Shifted Carrier Modulation Schemes Similar to the phase-shifted modulation, an m-level Cascaded H-Bridge inverter using level-shifted multicarrier modulation scheme requires (m 1) triangular carriers, all having the same frequency and amplitude. The (m 1) triangular carriers are vertically disposed such that the bands they occupy are contiguous. The frequency modulation index is given by mf = fcr/fm, which remains the same as that for the phase-shifted modulation scheme whereas the amplitude modulation index is defined as ma =
^ ^
^ ^ (in our case m = 5) where is the peak amplitude of the modulating wave Vm and is the peak amplitude of each carrier wave. Here three schemes for the level-shifted multicarrier modulation are simulated (a) in-phase disposition (IPD), where all carriers are in phase; (b) alternative phase opposite disposition (APOD), where all carriers are alternatively in opposite disposition; and (c) phase opposite disposition (POD), where all carriers above the zero reference are in phase but in opposition with those below the zero reference [4]-[7].
185
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
(a) IPD :
Fig-7 Triangular Carriers compared with Reference Sine for IPD Modulation
Fig-8 Output Current Waveform of the 5 level MCSI with IPD Modulation
100
200
300
400
600
700
800
900
1000
186
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
(b) APOD :
Fig-10 Triangular Carriers compared with Reference Sine for APOD Modulation
187
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
(c) POD :
Fig-13 Triangular Carriers compared with Reference Sine for POD Modulation
Fig-14 Output Current Waveform of the 5 level MCSI with POD Modulation
Fundamental (50Hz) = 1 , THD= 2.70% 10 9 8 Mag (% of Fundamental) 7 6 5 4 3 2 1 0 0 100 200 300 400 500 Frequency (Hz) 600 700 800 900 1000
188
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
Fig-16 Circuit Diagram of the 5 level CHB MVSI IV. RESULT Repeating the simulations with different frequencies for lowest THD has been done and then the modulation index ( M.I.) has been varied to further reduce the THD , the optimum frequency and modulation index in each case was found to be 900Hz and 1(for phase shifted multicarrier) and 0.25 (for level shifted ) respectively. The same cases were also tried out for a similar 5 level CHB MVSI (figure 16 shown above [8]-[9]) , the THD for each modulation technique is as follows : TABLE II THD (%) Results for Different Modulation Techniques for both MVSI and MCSI
Modulation Technique Angle Control Method Phase Shifted Multicarrier IPD APOD POD
189
International Journal of Advanced Research in Engineering and Technology (IJARET), ISSN 0976 6480(Print), ISSN 0976 6499(Online) Volume 4, Issue 2, March April (2013), IAEME
V. CONCLUSION It is concluded that for such a 5 level MCSI in CHB configuration for both the MVSI and MCSI the results are very similar moreover the prominent multilevel inverter modulation topologies (i.e., Phase shifted multicarrier, IPD, APOD and POD) are also giving similar results a minimum THD of 2.7 % has been obtained using the POD modulation scheme in both the MVSI and MCSI cases. VI. REFERENCES [1] Jian-yu Bao, Wei-bing Bao and Zhong-chao Zhang, High Generalized multilevel current source inverter topology with self-balancing current , Journal of Zhejiang University-SCIENCE C (Computers & Electronics), ISSN 1869-1951 (Print); ISSN 1869-196X (Online), 2010,pp. 555-561. [2] Muhammad H. Rashid, Power Electronics Circuits, Devices and Applications, Pearson Seventh Impression, 2009, pp. 280-282. [3] Jagdish Kumar, Biswarup Das, Senior Member, IEEE, and Pramod Agarwal, Selective Harmonic Elimination Technique for a Multilevel Inverter, Fifteenth National Power Systems Conference (NPSC), IIT Bombay, December 2008. [4] Bin Wu, High-Power Converters and ac Drives ,The Institute of Electrical and Electronics Engineers, Published by John Wiley & Sons Inc, 2006. [5] Ilhami Colak, Ersan Kabalci and Ramazan Bayindir A Review of multilevel voltage source inverter topologies and control schemes Energy Conversion and Management, Elsevier September 2010 pp. 1-2. [6] T.Prathiba, P.Renuga , A comparative study of Total Harmonic Distortion in Multilevel inverter topologies, Journal of Information Engineering and Applications, Vol 2, No.3, 2012. [7] Annetla Ramakrushna, Reddy & Suresh Kumar K S, Comparative Study of Multi Carrier Sine and Space Vector Modulation Techniques for Cascaded H-Bridge Inverter, International Conference on Electrical and Electronics Engineering, ISBN : 978-93-81693-85-8, 9th June, 2012. [8] Ganesh Prasad Reddy, K. Ramesh Reddy , Design and Simulation of Cascaded HBridge Multilevel Inverter Based DSTATCOM, International Journal of Engineering Trends and Technology- Volume3Issue1- 2012, ISSN: 2231-5381. [9] M.Murugesan, R.Sakthivel, E. Muthukumaran and R.Sivakumar , Sinusoidal PWM Based Modified Cascaded Multilevel Inverter, International Journal Of Computational Engineering Research, ISSN: 22503005, Mar-Apr 2012, Vol. 2, Issue No.2, pp.529-539. [10] Vinesh Kapadia and Dr.Hina Chandwani, A Review on Current Source Inverter Fed Ac Drives and Multilevel Current Source Inverters: Part -1: CSI Fed Ac Drives International Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 3, 2012, pp. 80 - 88, ISSN Print : 0976-6545, ISSN Online: 0976-6553. [11] Vinesh Kapadia and Dr.Hina Chandwani, A Review on Current Source Inverter Fed Ac Drives and Multilevel Current Source Inverters: Part -2: Multilevel CSIS International Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 3, 2012, pp. 102 - 109, ISSN Print : 0976-6545, ISSN Online: 0976-6553.
190