You are on page 1of 3

SK

SK

n LP

PB R

ACU

ACU

n LP

n LP

n LP

ref

up

down

ACU
n LP

ACU
n LP

A1 E-1

GROUND FLOOR POWER LAYOUT

A2 E-1

SECOND FLOOR POWER LAYOUT

_______________________
ARCHITECT

BOBBY LUPANGO
CIVIL ENGINEER DATE:

2-STOREY RESIDENTIAL BUILDING

JOHN CARLO T. PANGANIBAN


ARCHITECTURAL

o o

r t

e c

d f

e r b b r t t

S
j

a1

b1

c1

S
v

S S S

h k

a1 k

S
z

S
w

S3way
S
l l

y
3 LP

A1 E-1

GROUND FLOOR LIGHTING LAYOUT

A2 E-1

SECOND FLOOR LIGHTING LAYOUT

_______________________
ARCHITECT

BOBBY LUPANGO
CIVIL ENGINEER DATE:

2-STOREY RESIDENTIAL BUILDING

JOHN CARLO T. PANGANIBAN


ARCHITECTURAL

SCHEDULE OF LOADS
CKT. NO. CIRCUIT POLE POLE AT LOAD DESCRIPTION PANEL BOARD 1 2 3 4 5 6 7 8 9 10 11 12 2P 2P 2P 2P 2P 2P 2P 2P 2P 2P 2P 2P 20 20 20 20 20 20 20 20 20 20 20 20 8 - 18W FLUORESCENT FIXTURE & 6 - 18W PINLIGHT 2 - 18W FLUORESCENT: 1-200W CEILING FAN & 12-18W PINLIGHT 4-18W FLUORESCENT: 1-120W CEILING FAN: 4-18W PINLIGHT & 2-100W SPOTLIGHT 2 - 18W FLUORESCENT: 1-200W CEILING FAN & 12-18W PINLIGHT REFRIGERATOR OUTLET 4 KVA ELECTRIC STOVE @ 80% D.F. 9-DUPLEX CONVENIENCE OUTLET ACU OUTLET ACU OUTLET ACU OUTLET 5-DUPLEX CONVENIENCE OUTLET 7-DUPLEX CONVENIENCE OUTLET SUB-TOTAL 1400 2600 2200 1400 750 4000 2970 3000 3000 3000 1650 2310 220 220 220 220 220 220 220 220 220 220 220 220 6.36 11.82 10.00 6.36 3.41 18.18 13.50 13.64 13.64 13.64 7.50 10.50 128.55 2-3.5mm THHN in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-5.5mm THHN + 2.0mm THHN GROUND WIRE in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-5.5mm THHN + 2.0mm THHN GROUND WIRE in 15mm IMC 2-5.5mm THHN + 2.0mm THHN GROUND WIRE in 15mm IMC 2-5.5mm THHN + 2.0mm THHN GROUND WIRE in 15mm IMC 2-3.5mm THHN in 15mm IMC 2-3.5mm THHN in 15mm IMC KW VOLTS LOADS (AMPS) SIZES OF WIRE AND CONDUITS

GENERAL NOTES:
ALL ELECTRICAL WORKS HEREIN INCLUDED SHALL EXECUTED IN ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE LOCALITY AND THE REQUIREMENTS OF THE POWER COMPANY. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED BY EXPERIENCED MEN UNDER THE DIRECT SUPERVISION OF A FULL TIME LICENSED ELECTRICAL ENGINEER AND A DULY ACCREDITED ELECTRICAL CONTRACTOR BY PCAB. WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHED. TYPE OF SERVICE ENTRANCE SHALL BE THREE-PHASE, THREE -WIRE PLUS GROUND. ALL MATERIALS SHALL BE NEW AND SHALL CONFORM WITH THE INTERNATIONALLY ACCREDITED RECOGNIZED STANDARDS, IN EVERY CASE WHERE SUCH STANDARD HAS BEEN ESTABLISHED FOR THE PARTICULAR TYPE OF MATERIAL IN QUESTION. ALL FEEDER CONDUITS SHALL BE INTERMEDIATE METALLIC CONDUIT (IMC) OF HIGH STRENGTH AND GALVANIZED WITH AN ADDITIONAL INTERIOR PROTECTIVE COATING SHALL BE USED OR AS INDICATED ON THE PLAN ALL EMBEDDED PLAN BRANCH CIRCUITS SHALL BE PVC CONDUITS AND FOR EXPOSED INSTALLATION SHALL BE EMT. ELECTRICAL TRADE SIZE SHALL BE USED, A MINIMUM OF 15mm FOR CONDUITS AND IN NO CASE SHALL THERE BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS IN ANY ONE RUN. SINGLE CONDUCTOR INSULATED THHN / THWN THERMOPLASTIC 600 V WIRES SHALL BE USED IN CONDUIT. MINIMUM SIZE OF WIRES SHALL BE 3.5mm THHN FOR ALL LIGHTING AND POWER SYSTEM. WALL SWITCHES SHALL BE RATED 15 AMPERES, 300 VOLTS TUMBLER TYPE AND CONVENIENCE OUTLET SHALL BE OF GROUNDING TYPE THREE-WIRE, 250 VOLTS OR AS INDICATED ON THE PLANS SPECIFICATIONS. MOUNTING HEIGHTS OF DEVICES SHALL BE AS APPROVED BY THE ARCHITECT AND/OR AS FOLLOWS: PANEL BOARD....................................................1.82 M. above finished floor to top of panel WALL SWITCHES ............................................... 1.37 M. above finished floor to center of device CONVENIENCE OUTLET .................................... 0.30 M. above finished floor to center of device or 0.15 M. above working counter to center of device

1ST 13.54 AMPS (300KVA) @ 100% REMAINDER @ 35% (128.55 - 13.54)*0.35 GRAND TOTAL FOR WIRE: Iu = (55.66)*(1.25) = 67.24 AMPS USE: 2-22mm THHN IN 32mm IMC

13.54 40.25 53.79

MAIN BREAKER USE: 75AT, 2P, 220V, PANEL BOARD MUST HAVE PROVISIONS FOR GROUND LUGS

LEGEND:
CEILING FAN WITH LIGHTING, MAXIMUM 1200W

MISCELLANEOUS SYMBOLS POWER


PB PANEL BOARD

CIRCUIT RUN UNDERFLOOR, CEILING OR BETWEEN WALL PARTITION 100 WATTS LIGHTING OUTLET. LIGHTING FIXTURE SHALL BE OWNER SUPPLIED 100 WATTS CEILING MOUNTED SPOTLIGHT 18 WATTS DOWNLIGHT, SCREW TYPE. 18 WATTS EYEBALL HALOGEN PINLIGHT, SCREW TYPE
C 1 LP

CIRCUIT HOMERUN DESIGNATION, UPPER HALF DENOTES CIRCUIT NO. WHILE LOWER HALF DESIGNATES POWER SOURCE OF THE CIRCUIT. POWER SERVICE ENTRANCE, WITH WEATHER PROOF ENTRANCE CAP. DUPLEX CONVENIENCE OUTLET, 3-WIRE GROUNDING TYPE, 250 VAC 10 A, NAT. CAT. NO. WN 1101-7 COLOR OF PLATE COVER TO BE APPROVED BY ARCHITECT/OWNER DITTO, BUT MOUNTED ABOVE WORKING COUNTER, 150mm ABOVE COUNTER

100 WATTS FLOODLIGHT WITH MOTION DETECTOR. SHALL BE OWNER SUPPLIED

WP

DITTO, BUT WITH WEATHER PROOF COVER, NAT. CAT. NO. WIN 7902 SINGLE CONVENIENCE OUTLET, 3-WIRE GROUNDING TYPE REF. - REFRIGERATOR D - DRYER

RANGE OUTLET

SINGLE POLE SWITCH, 15 A, 300 VAC NAT. CAT. WIN 5001-7

2Sab

TWO GANG SWITCH, 15A 300VAC

3Sabc

THREE GANG SWITCH, 15A 300VAC

S3Wa

ONE GANG THREE WAY SWITCH 15 A, 300VAC

LIGHTING OUTLET

DITTO, BUT WALL MOUNTED

PINLIGHT, RECESSED MOUNTED WITH 100W BULB, 230 VAC