You are on page 1of 1

The Block Diagram of the CB42 is shown in Fig. 61 betweensections.

This designapproachalso allows any


Each of the sectionsin the block diagram is isolated circuit troubleshooting to quickly isolate a malfunction
from the other sectionswith power supply filtering and to a single circuit board by injecting signalsor monitor-
electrical shielding. This results is very little interference ing signals at the front panel input/output jacks.

COMPLETECIRCUITDESCRIPTION
The complete circuit description for the C842, with dling chargefrom the SencoreField EngineeringDepart-
simplified circuit diagrams, is available for $b.00 han- ment, 3200 SencoreDrive, Sioux Falls, S.D. 57107.

ACCESS,/DISASSEMBLY
To gain accessto the interior of the CB42 for main- and the two screwson the top of the case.Remove
tenanceor calibration, follow this procedure: the caseby sliding it towards the rear of the unit.
1. RemoveAC power from the CB42by disconnecting As the case is removed, feed the AC cord through
it from the AC line. the hole in the caseuntil the case is clear of the
unit.
2. Remove the six screws in the bottom panel and
slide the panel towards the rear of the unit to 4. Complete accessis available for calibrating the
remove it. CB42 without further disassembly.
3. Remove the two screwson either side of the case. 5. To reassemble,simply reverse the steps above.

CALIBRATIONPROCEDURE E O U I P M E N TR E O U R :
I EMENTS
The calibration of the CB42 should be checkedat regu- EQUIPMENT SPECIFICATIONS
lar intervals to make sure it is within original accuracy
Frequencycounter .00017o(1ppm)
specifications.It is recommendedthat any unit requiring
or
recalibration be returned to one of the SencoreSales Frequencystandard
and ServiceOfficeslisted in the inside back cover of the
manual. If field calibration is desired,follow the steps RF Voltmeter t0Voacarracy,10uV-.1VRF at 30 MHz
DC Voltage Source . I V o, 2 5 m V - 1 0V D C
listed below:
AC Voltmeter lVo,0-2 VAC RMS at 1000Hz.
AC Signal Source .500 VRMS ! lVo at 1000Hz.
RF Power Source 3.00WRF *1Vo at27 MHz.

POWERSUPPLY
1. Measure ripple on 10 volt output of power supply
PC board. Should indicate less than 30 mV.
2. Measureripple on 5 volt output of powersupply PC
board. Should indicate lessthan 30 mV.
3. Monitor DC voltage of 10 volt output of power sup-
ply PC board. Set l0 Volt Adjust (R104)for 10.00
V t 0.1 VDC.

SCOPEADAPTER
1. Feed26.965MHz (CB channel1) into 50 ohmin-
pur.
2. Connectscopeto ScopeAdapter output.
3. Set ScopeAdapter FrequencyAdjust for zero-beat
on scope.
4. Readjust L701 for 40 KHz output on scope.
D. Switch RF input to 26.975MHz (CB channel 2).
Frequencyon scopeshould increase.If Channel 2
frequencyis Iower than channel 1 frequency,repeat
step 4 for 40 KHz signal on oppositeside of zero- Fig. 62-Test-points and controls on bottom of
beat.
chcssls.

49

You might also like