You are on page 1of 7

EMF Survey Report

Radio Frequency Fields (Antenna Emissions)

Prepared for [ Client Name ]

Site Locations [ Location 1 ] [ Location 2 ]

1st Survey Date: [ 1st Date ] 2nd Survey Date: [ 2nd Date ] Report Date: [ Report Date ]

EMF SERVICES
15681 Sonoma Drive #201 Fort Myers, FL 33908 Phone (239) 209-1418 Fax (866) 321-2082 www.emfservices.com

RF Report Sample
Excerpts Only
TABLE OF CONTENTS

1.0

SUMMARY AND CONCLUSIONS 1.01 1.02 1.03 Measurement Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Exposure Significance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Recommended Corrective Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.0

BACKGROUND INFORMATION 2.01 2.02 2.03 2.04 Referenced Exposure Guidelines (FCC) . . . . . . . . . . . . . . . . . . . . . . . . . 4 Informal Precautionary Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 International RF Protection Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Radio Frequency Measurement Units . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.0

SURVEY METHODOLOGY 3.01 3.02 Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

APPENDIX

MEASUREMENT DATA

Detailed Measurement Results Test Locations Spectrum Analyzer Plots Site Photos Equipment Calibration Certificates

Appendix

DETAILED MEASUREMENT RESULTS


PT # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Survey Total RF Power nW/cm2 8.2 1.1 1.5 0.5 0.4 0.2 0.7 1.0 % Total Power from FM 22% 51% 49% 50% 38% 50% 47% 71% % Total Power from TV 5% 14% 19% 20% 37% 12% 35% 9% % Total Power from Cell 73% 35% 31% 30% 26% 38% 18% 20% Total Cell RF Power nW/cm2 6.0 0.4 0.5 0.2 0.1 0.1 0.1 0.2

Location Sample Location 1 Outside Sample Location 2 Sample Location 3 Sample Location 4 Sample Location 5 Sample Location 6 Sample Location 7 Sample Location 8

% MPE 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%

Notes % MPE = % FCC Maximum Permissible Exposure. Calculation is based on cumulative MPEs for multiple frequency ranges. Total Cell levels exceeding 100 nW/cm2 are highlighted in red (represents informal precautionary exposure guideline for pulsed signals). 1000 nanoWatts ( nW/cm2 ) equals 1 microWatt ( uW/cm2 ) 100 nanoWatts ( nW/cm2 ) equals

1 2

st

nd

1st 2nd 1st 2


nd

1st 2nd 1st 2


nd

1st 2
nd

1st 2
nd

1st 2nd 1st 2nd 1 2


st nd

Sample Location 10 Outside Sample Location 11 Outside Sample Location 12 Outside Sample Location 13 Sample Location 14 Sample Location 15

28.7 62.7 202.4 2.2 6.1 0.9

0.01% 0.01% 0.04% 0.00% 0.00% 0.00%

11% 8% 1% 3% 3% 9%

14% 38% 19% 50% 46% 25%

75% 53% 80% 47% 51% 66%

21.5 33.5 162.6 1.0 3.1 0.6

0.1 microWatt ( uW/cm2 ) 1 nanoWatts ( nW/cm2 ) equals 0.001 microWatt ( uW/cm2 )

1st 2
nd

1st 2nd 1 2 2 2
st nd

1st
nd

1st
nd

DETAILED MEASUREMENT RESULTS


PT # 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Survey Total RF Power nW/cm2 0.4 5.6 0.2 0.2 6.3 15.5 % Total Power from FM 34% 1% 54% 21% 0% 15% % Total Power from TV 63% 97% 12% 63% 99% 79% % Total Power from Cell 4% 1% 34% 16% 0% 6% Total Cell RF Power nW/cm2 0.0 0.1 0.1 0.0 0.0 0.9

Location Sample Location 15 Sample Location 15 Sample Location 15 Sample Location 15 Sample Location 20 Sample Location 21 Outside

% MPE 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%

Notes % MPE = % FCC Maximum Permissible Exposure. Calculation is based on cumulative MPEs for multiple frequency ranges. Total Cell levels exceeding 100 nW/cm2 are highlighted in red (represents informal precautionary exposure guideline for pulsed signals). 1000 nanoWatts ( nW/cm2 ) equals

1 2

st

nd

1st 2nd 1st 2


nd

1st 2nd 1st 2 2 2


nd

1st
nd

1st
nd

1st 2nd 1st 2nd 1 2


st nd

Sample Location 23 Outside Sample Location 24 Outside Sample Location 25 Outside Sample Location 26 Sample Location 27 Sample Location 28 Sample Location 29 Sample Location 30

6.3 35.9 5.9 9.3 0.9 1.1 2.5 0.4

0.00% 0.01% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%

20% 6% 3% 1% 42% 11% 17% 23%

52% 51% 10% 98% 51% 86% 81% 53%

28% 44% 87% 1% 7% 4% 2% 24%

1.8 15.7 5.1 0.1 0.1 0.0 0.1 0.1

1 microWatt ( uW/cm2 ) 100 nanoWatts ( nW/cm2 ) equals 0.1 microWatt ( uW/cm2 ) 1 nanoWatts ( nW/cm2 ) equals 0.001 microWatt ( uW/cm2 )

1st 2
nd

1st 2
nd st

1 2

nd

1st 2
nd

1st 2
nd

RF Spectrum Analyzer Plots


1st Survey 2nd Survey