You are on page 1of 2

We are interested in your safety! Imitations are interested in your money! We are interested in your safety!

n your safety! Imitations are interested in your money!

General Specs for Customized Professional CLLI MD-4Ccu(+12V or +24V-2A or 1A) Connect EARTH-
• Each pin (1&2) is DATA- terminal to EARTH-
(Made-to-order versions / Non-standard CLLI / Approx. values +/-20%) compatible at 5V to EARTH terminal at power-CLLI
CLLI-model or version DATA V-rms V- A-ops A-iso
clamp (Normal) (Isolating) • Clamping-voltage: ~10V to Pin-to-pin feed-
1 MD-8Ccu 5V - - - 3A EARTH through from
2 MD-4Ccu 5V - - - 3A • Pins 3&4 are voltage- cable to
3 MD-4Ccu(+12V) 5V 20V 45V 1A 3A compatible to specified equipment-port
4 MD-4Ccu(+24V) 5V 30V 50V 1A 3A voltage at specified current- or connections
5 MD-4Ccu(12V) - 20V 45V 1A 3A
6 MD-4Ccu(24V) - 30V 50V 1A 3A
rating
7 MD-4Ccu(CB-36V) 36V 40V 80v 1A 3A
8 MD-4Ccu(CB-24V) 24V 30V 50V 1A 3A
9 MD-4Ccu(CB-12V) 12V 20V 45V 1A 3A
10 DCJ-cu(12V-2A) - 20V 45V 2A 5A
11 DCJ-cu(12V-1A) - 20V 45V 1A 3A MD-4Ccu(12V or 24V-2A or 1A) Connect EARTH-
12 DCJ-cu(24V-1A) - 30V 50V 1A 3A terminal to EARTH-
13 DCJ-cu(24V-2A) - 30V 50V 2A 5A
• Pins 1&2 / 3&4 are voltage-
compatible to specified terminal at power-CLLI
14 DCJ-cu(DATA) 5V - - - 3A
15 MD-SC3C-cu(xV-10A) - - - 10A 15A Optional voltage at specified current
Pin-to-pin feed-
16 MD-SC3Ccu - 275V 430V 2A 4A Optional • Clamping-voltage: approx. through from
double the operating voltage cable to
Applications-guide to EARTH equipment-port
• Rated current is continuous- or connections
MD-8Ccu operating current. Isolations
• Each core (1 to 8) is DATA- Connect green- depends on rate-of-rise and
compatible at 5V to EARTH wire to EARTH-
duration.
• Clamping-voltage: ~10V to terminal at
power-CLLI
EARTH
• May be used to protect at MD-4Ccu(CB-12V or 24V or 36V-1A) Connect EARTH-
RS-232 or RS-485 with • Pins 1&2 / 3&4 are DATA & terminal to EARTH-
suitable conversions voltage-compatible at terminal at power-CLLI
(Technical know-how Connect RJ-45 plugs from line- specified voltage at 1A
cable to equipment-port via Pin-to-pin feed-
needed) • Clamping-voltage: approx. through from
this CLLI
double the operating voltage cable to
to EARTH equipment-port
• Rated current is continuous- or connections
MD-4Ccu Connect EARTH- operating current. Isolations
• Each pin (1 to 4) is DATA- terminal to EARTH-
terminal at power-CLLI
depends on rate-of-rise and
compatible at 5V to EARTH duration.
• Clamping-voltage: ~10V to
EARTH Pin-to-pin feed-
through from
• May be used to protect at cable to Important:
LAN or DATA cable up to 2- equipment-port Professional-CLLI series is made-to-order by customized SPECS &
pairs, with suitable or connections REQUESTS. Please make sure you provide sufficient info for our Tech-
conversions (Technical support engineers so that effective proposals may be generated.
know-how needed) < Private-label & OEM can be considered >
Email callab@callab.com.my or call 012-771 8225 or visit www.cal-lab.com

We are interested in your safety! Imitations are interested in your money! We are interested in your safety! Imitations are interested in your money!
We are interested in your safety! Imitations are interested in your money! We are interested in your safety! Imitations are interested in your money!

MD-SC3Ccu(240V-2A or 1A or 5A) Connect EARTH- DCJ-cu +E (12V or 24V / 2A) – for CCTV Camera power-side
• Pins 1&2 are voltage- terminal to EARTH- • DC-jack input & output are Connect EARTH-
compatible to specified terminal at cable-CLLI voltage-compatible to specified terminal to EARTH-
voltage at specified current voltage at specified current terminal at cable-CLLI
Pin-to-pin feed- • Clamping-voltage: approx.
• Clamping-voltage: approx. through from double the operating voltage to
double the operating voltage Power-supply to EARTH
to EARTH equipment • Rated current is continuous- Pin-to-pin feed-
• Rated current is continuous- connections operating current. Isolation through from
operating current. Isolation depends on rate-of-rise and Power-supply to
depends on rate-of-rise and duration. equipment
duration. connections

MD-BNC (0E) – for CCTV Camera at signal cable & at DVR


MD-SC3Ccu(12V or 24V or 36V / 10A)
• Pins 1&2 are voltage- Connect EARTH- • BNC-jack input & output are
compatible to specified terminal to EARTH- DATA & voltage-compatible to
voltage at specified current terminal at cable-CLLI Connect EARTH-wires to
camera-signal
one reference point at
• Clamping-voltage: approx. • Clamping-voltage: approx. 10V
Power-CLLI at DVR-side
Pin-to-pin feed- and shorted to EARTH
double the operating voltage through from
to EARTH • Connect all EARTH-wires to one
Power-supply to DCJ-cu +E
• Rated current is continuous- point at CLLI for DVR power-
equipment
supply
operating current. Isolation connections
• At camera-side, short CLLI
depends on rate-of-rise and EARTH–wires together to form
duration. one safe-island (floating). DCJ-cu
• Where the camera needs to be
grounded, use only MD-BNC Pin-to-pin feed-
(Std-version with EARTH-filter) through from CABLE
DCJ-cu(12V or 24V or 36V-2A or 1A) • For use with HIGH-speed DATA- to equipment
• Pins 1&2 are voltage- Connect EARTH- cable using BNC-co-ax cable, connection
compatible to specified voltage terminal to EARTH- use only MD-BNCcu(DATA)
at specified current terminal at cable-CLLI
• Clamping-voltage: approx. IMPORTANT:
double the operating voltage to This MD-BNC version has been designed to be as small as possible. As
Pin-to-pin feed-
EARTH
through from a result, it may NOT be as rugged as can be expected!!
• Rated current is continuous- Power-supply to
operating current. Isolation
Excessive use of force or prolonged pulling may cause the copper-lead
equipment or copper-pads or tracks on the PCB to give way.
depends on rate-of-rise and connections
duration.

DCJ-cu(DATA)
NOTE:
Professional-CLLI series is made-to-order by customized SPECS &
• Each pin (1&2) is DATA-
REQUESTS. Please make sure you provide sufficient info for our Tech-
compatible at 5V to EARTH
support engineers so that effective proposals may be generated.
• Clamping-voltage: ~10V to < Private-label & OEM can be considered >
EARTH Email callab@callab.com.my or call 012-771 8225 or visit www.cal-lab.com

We are interested in your safety! Imitations are interested in your money! We are interested in your safety! Imitations are interested in your money!

You might also like