Data Sheet Whr Parklift 440-2,0

Single unit = 2 cars Double unit = 4 cars


25 25 * In case of short time user only possible on upper platform and only if technically adjusted, ask WHR! Or with attendant or valet parking both levels are possible for short time user. Special reinforced units for higher platform loadings are available (see 440-2.6). Both platforms are in a horizontal position to drive in. Load per platform max. 2000 kg (load per wheel max. 500 kg)

Suitable for condominium and ofce buildings. For permanent use only!*
40 80

40

free space for door


X

free space

40

clear height for a lintel h 15 80

= only applicaple if garage doors are to be fitted. For roller doors x = 10/15 cm = to be clarified with door supplier

max. + 3% slope max. -10% slope min.18


e ac sp le on b i i ss ct po r su fo

for ning ope and es wallctrical servic ele raulic h yd

5 1

re ch co fo ann mm r s e en um l 1 de p 0 x d dr pu 2 ai m plu na p s ge 50 re x 5 ce 0 ss x2 0

Dimensions in cm

12%

slope12%

min.18

50 390 530 540

Standard type 440-185/180 2000 kg

Compact type 440-170/165 2000 kg

Comfort type 440-200/195 2000 kg

355 +3 0

325 +3 0

385+3 0

185 +3 0

180+3 0

170

+3 0

165

+3 0

200+3 0

195

+3 0

Upper level Lower level

car height distance (h) saloon/estate cars up to 165 cm saloon/estate cars 170 up to 165 cm

Upper level Lower level

car height distance (h) saloon/estate cars up to 150 cm saloon/estate cars 155 up to 150 cm

car height distance (h) Upper level cars/vans up to 180 cm and max. 2000 kg Lower level cars/vans up to 180 cm 185 and max. 2000 kg Clear height of 355 cm is sufficient, if just cars up to a height of 150 cm shall be parked on the upper level.

Clear height of 340 cm is sufficient, if just cars up to a height of 150 cm shall be parked on the upper level.

Please attend to restricted car- and platform distance height!

Clearance prole (standard saloon/estate car)


10 25 20 90 55 65 162 8 48 150* 46 (165*) (180*) 22 60 120 14 max. 290 500 38 90

10 40 40

60

162

8 48
150* 46 (165*) (180*) 22

275

275

*The total car height includes roof rail and antenna xture and must not exceed the mentioned max. height dimension.

Parklift 440 | 05.2010 | C027-4303 | Otto Whr GmbH

60 120

14 max. 290 500

38 90

Notes
1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehicle width is reduced accordingly. For cars with two outside mirrors, a minimum platform width of 250270 cm or 500540 cm is recommended. 2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable. This offers bigger safety distances also for future cars. 3. At the edge of the pit a 10 cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser (see statics and construction requirements on page 3). 4. It is not possible to have channels or undercuts and/or concrete haunches along the pit oor-to-wall joints. In the event that channels or undercuts are necessary, the system width needs to be reduced or the pit needs to be wider. 5. The manufacturer reserves the right to modify or alter above specications.

Otto Whr GmbH


01 Auto-Parksysteme

P. O. Box 1151 71288 Friolzheim

Fon +49 [0] 7044 46 -0 Fax +49 [0] 7044 46 -149

www.woehr.de info@woehr.de

We compact parking space

Width dimensions Underground garages


All dimensions shown are minimum. Construction tolerances must be taken into consideration. All dimensions in cm. The access to the Parklift is possible with max. 3% declination and max.10% inclination. If not stated differently in the offer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be delivered at additional price. With platform widths 250, 260 and 270 cm special reinforced units with max. platform loading capacity of 2.300 kg are available for big limousines e.g. Mercedes-Benz S-class

Wall to wall
Single unit (2 cars) Double unit (4 cars) Combinated unit (6 cars) Wall openings required between partitions for electrical and hydraulic conduits must be provided where applicable. Wall openings may not be closed after installation.

S
B

D
B S Space required B 490 510 530 550 570

D
B

Space required B 260 270 280 290 300

gives clear platform width 230 240 250 260 270

gives clear platform width 460 480 500 520 540

Space required B 750 780 810 840 870

gives clear platform width 460+230 480+240 500+250 520+260 540+270

M Minimum driveway width according to local requirements

Further width combinations as well as smaller widths are possible

Pillars outside pit


Single unit (2 cars) Double unit (4 cars) Combinated unit (6 cars)

S
B

S
B1

D
min. 20 B

D
B1

D
B

S
min. 20

D
B1

min. 20

Space required wallpillarpillar pillar B B1 250 240 260 250 270 260 280 270 290 280

gives clear platform width 230 240 250 260 270

Space required S wallpillarpillar pillar B B1 480 470 500 490 520 510 540 530 560 550

gives clear platform width 460 480 500 520 540

Space required wallpillarpillar pillar B B1 740 730 770 760 800 790 830 820 860 850

gives clear platform width 460+230 480+240 500+250 520+260 540+270

Minimum driveway width according to local requirements

Further width combinations as well as smaller widths are possible F

Pillars inside pit


Single unit (2 cars) Double unit (4 cars) Combinated unit (6 cars)

S
min.15

S
max.100

D
min.15t

D
max.100 B1

S
min.15

D
max.100 B1

B1

Parklift 440 | 05.2010 | C027-4303 | Otto Whr GmbH

S Space required wallpillarpillar pillar B B1 255 245 265 255 275 265 285 275 295 285

gives clear platform width 230 240 250 260 270

Space required wallpillarpillar pillar B B1 485 475 505 495 525 515 545 535 565 555

gives clear platform width 460 480 500 520 540

Space required wallpillarpillar pillar B B1 745 735 775 765 805 795 835 825 865 855

gives clear platform width 460+230 480+240 500+250 520+260 540+270

Minimum driveway width according to local requirements

F Further width combinations as well as smaller widths are possible

Important notes
If maximum platform widths are not installed, difculties might arise when entering or exiting the cars on the parking units. This depends on the car type, the access and the individual driving behaviour. Cars wider than 190 cm should be parked on platforms 270/540 cm width only. For spaces against walls, or at end of rows, we recommend that largest possible platform widths are utilized to assist turning motion.

02

Width dimensions Garages with doors


All dimensions shown are minimum. Construction tolerances must be taken into consideration. All dimensions in cm. The access to the Parklift is possible with max. 3% declination and max.10% inclination. If not stated differently in the offer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be delivered at additional price. With platform widths 250, 260 and 270 cm special reinforced units with max. platform loading capacity of 2.300 kg are available for big limousines e.g. Mercedes-Benz S-class

Single garages (2 cars)


B

Double garages (4 cars)


B x = for doors. See page 1 Wall openings required between partitions for electrical and hydraulic conduits must be provided where applicable. Wall openings may not be closed after installation.

S
X 15 B1 15 gives clear platform width 230 240 250 260 270 5 1

D
B1 1 5 gives clear platform width 460 480 500 520 540

Space required B1 B 260 230 270 240 250 280 290 260 270 300

Space required B1 B 490 460 510 480 500 530 550 520 540 570

Minimum driveway width according to local requirements

Serial garages with single doors (2 cars)


B B B

Serial garages with double doors (4 cars)


B B B

S
X 15 B1 30

S
B1 30

S
B1 30 15

D
B1 30

D
B1 30 gives clear platform width 460 480 500 520 540 Minimum driveway width according to local requirements

Space required B B1 260 230 270 240 280 250 290 260 300 270

gives clear platform width 230 240 250 260 270

Space required B B1 490 460 510 480 530 500 550 520 570 540

Statics and construction requirements


Single unit
P1 P4 P4 P1 P2 P3 P4 P2 P3 P4

P1 =+36 kN * 7 kN clear platformwidth +15 P2 = + 2 kN 3 kN P3 =+14 kN 3 kN P4 = + 3 kN


P4 P1
+ -

P4

5
5 11
P2
-

A
P3
+ -

Marking according to ISO 3864 Double unit


P1 P4 P2 P3 P4

P2 = + 3 kN 6 kN clear platformwidth +15 P3 =+23 kN 3 kN P4 = + 3 kN *all static loadings include the weight of the car

~485 ~500
Parklift 440-165/170 Parklift 440-185/180 Parklift 440-200/195

P4 P1 P2 P3 P4

A 72 57 42

Hydraulic power pack


The location of the hydraulic power pack is determined according to your plan space requirements are as follows: Dimensions are in cm Length = Height = Depth = 1 5 Parklifts 100 140 35 6 10 Parklifts 150 140 35

Parklift 440 | 05.2010 | C027-4303 | Otto Whr GmbH

P1 =+66 kN 6 kN

~200

Bearing loads are transmitted to the pit oor by base plates of approximately 140 cm2, xed by heavy duty anchor bolts to a depth of approximately 1012cm. Base plate thickness min. 18 cm. Concrete quality according to the static requirements of the building, but for the dowel fastening we require a concrete quality of min. C20/25. When xing to waterproof concrete oors chemical anchors are employed (to be advised by Whr). The front wall of the pits must be formed of concrete and must be perfectly at and vertical without any protrusions. The specied lengths to the support points are mean values. Please contact us for exact positions for any variations on the standard units.

03

Electrical datas
Item Performance Quantity Designation 1 2 by customer 1 unit by customer 1 unit electric meter Position in the feed cable 1 per power pack 1 per power pack Frequency

Installation diagram
1 Electric meter 2 Fuse or automatic circuit breaker 3 x16A slow blow according to DIN VDE 0100 part 430 3 Feed line to the main switch 6 Lockable main switch conduit 1 per Parklift 1 per power pack 120 cm 1 10 cm 13 PVC control cable 7 x1,5 2 14 Cylinder valve cable PVC control cable 3 x1,5 2 7 PVC control cable 5 x 1,52 from main switch to assembly 8 Hydraulic unit with three-phase motor, 230/400V, 50Hz, 1.5/3.0 kW. Switching cabinet with motor, protection, wired already for installation 9 PVC control cable 5 x1,52 10 Branch 4 Equipotential bonding safety lead-out connection 5 Equipotential bonding safety from the lead-out connection to the system 11 PVC control cable 5 x1,52 to the next facility

fuse or automatic circuit in the feed cable breaker 3x16A slow blow acc. to DIN VDE 0100 p. 430 feed cable to main switch corner pit oor/ rear wall from the lead-out connection to the system

4 5

by customer as locally acc. to local power supply required regulations 3 Ph + N + PE* by customer each equipotential bonding safety lead-out connection 10 m by customer 1 unit equipotential bonding safety compliant to the DIN EN 60204 standard by customer 1 unit

marked main switch, above operating device lockable to prevent unauthorized switching on

PVC control cable with from main switch 1 per marked strands and proto hydraulic power power pack tective conductor 5 x 1,5 2 pack Items 814 are included in Whrs scope of delivery unless otherwise specied in the offer/order. 7

by customer 10 m

12 Operating device for UP/DOWN with EMERGENCY-STOP. If possible on the left, but always outside the platforms movement range. Cables always feed in from below. (2 keys per parking place.)

* DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE (three-phase current) Note: Where a door is used to close the garage, the manufacturer of the door must be consulted before the electric cable is laid. The electrical components suppliedbythemanufacturer must be connected in accordance with the appropriate wiring diagram and local regulations. German VDE electrical requirements must be adhered to, in order to validate the TV tested circuit. The electrical supply to the power pack(s) must be provided prior to or during installation to enable our tters to complete their work satisfactorily and to check the correct functioning of the units. In compliance with the DIN EN 60204 standard provisions, all systems must be connected directly on site with an earthed equipotential bonding. The leadout connection must be at a 10 m distance!

Recesses and conduits for rotary switches with rolling and sectional gates
Above plaster Under plaster

15 15 above access level 1 =


B A

=
B

min.20
A

= 7 +0,5 8

Noise protection
Basis is the German DIN 4109 Noise protection in buildings. With the following conditions required 30 dB (A) in rooms can be provided: noise protection package from our accessory insulation gure of the construction of min. Rw = 57dB walls which are bordering the parking systems must be done as single wall and deection resistant with min. m= 300 kg/m2 solid ceiling above the parking systems with min. m= 400 kg/m2 At differing constructional conditions additional sound absorbing measures are necessary. The best results are reached by separated sole plates from the construction. Increased noise protection: If increased noise protection must be provided planning has to be conrmed on a project basis by Whr (further building measures are required).

8
A B

Plastic or steel armoured conduit M 20 Flexible plastic insulation pipe M 20

Railings
The units need to be provided acc. EN ISO 13857 with safety railings if the gap between unit and wall exceeds 20cm. If walkways are arranged directly to the side or behind the systems, railings have to be provided by client acc. to local requirements, height min. 200 cm this is applicable during the construction phase too.

Free spaces
Special drawings for free spaces to accommodate air ducts or other pipes can be requested at Whr Agent!

Temperature
The installation is designed to operate between +5and +40C. Atmospheric Humidity: 50% at +40C. If the local circumstances differ from the above please contact Whr.

Maintenance
Regular maintenance by qualied personnel can be provided by means of an Annual Service Contract.

Drainage
We recommend the provision of a drainage channel at the front of the pit which can either incorporate a pump sump 50 x 50 x 20 cm, or a connection into the storm water sewerage system via a petrol/oil interceptor. To prevent any possibility of contamination of the groundwater we recommend that the pit oor is coated with an oil proof paint.

Protection against corrosion


Independent of a maintenance workings has to be carried out acc. to Whr Cleaning and Maintenance Instruction regularly. Clean up galvanized parts and platforms of dirt and road salt as well as other pollution (corrosion danger)! Pit must be always ventilated and dearated well.
Parklift 440 | 05.2010 | C027-4303 | Otto Whr GmbH

Conformity test
All our systems are checked according to EC machinery directive 2006/42/EC and EN 14010.

Dimensions
All dimensions shown are minimum. Construction tolerances must be taken into consideration. All dimensions in cm.

Illumination
Illumination has to be considered acc. to local requirements by client.