New T series Three phase Transducer TR3

AE TR3 series Transducers converts various electrical parameters viz. Active Power(P), Reactive Power(Q) Apparent Power (S) , Active Power Factor(PF), Reactive Power Factor(QF), Average RMS Voltage(V) or Average RMS Current of Three Phase System(Three phase single element, Two Element or Three Element) into DC Current or DC Voltage Output. The transducers give galvanivcally isolated and Load independent outputs. These are used in various electrical, thermal, chemical & other power plants to monitor processed Data either locally or from remote using various devices such as indicating meters, data loggers, recorders, SCADA systems. These transducers can also be used as external unit in conjunction in analog or digital indicators. FEATURES: 0.5 accuracy class 3Phase4Wire, 3Phase3 Wire(Unbalanced Load) or 3 Phase 1 Element(Balanced Load) Open & short circuit protection for outputs. Two galvanically isolated outputs. Standard DC Current & Voltage outputs are independent of load impedance. Suitable for DINRAIL as wellas Wall mounting. APPLICABLE STANDERDS IS12784 Electrical measuring Transducer for converting a.c. electrical quantities into DC electrical quantity specifications. Transducer for general applications. Electrical measuring Transducer for converting a.c. electrical quantities to analogue or digital signals.

IEC 60688

Electrical Specifications : Type Input Parameters : : TR 3 Series Active Power(P), Reactive Power(Q) Apparent Power (S) , Active Power Factor(PF), Reactive Power Factor(QF), Average RMS Voltage(V) or Average RMS Current(I). : : : : AC 0600 V PP AC 1A/ 5A, 010 A 50/60 Hz +/ 10 % 0.5 lag unity 0.5 lead

Input Parameter Ranges: Voltage Current Frequency Power Factor

Output ranges

Single output/ Dual Output Voltage Output load Capacity : 20 mA Current o/p Burden Voltage : 20 V Max. Load Resistance 15k 4k 2k 1 k Voltage Output Range 01 V or 1V 05 V or 5V 010 V or 10V Min. Load Resistance 50 250 500

Current Output Range 01 mA or 1mA 05 mA or 5mA 010 mA or 10mA 020 mA or 20mA or 420mA Accuracy Aux. Supply VA Burden : : :

0.5% of output Span 60 285 V AC/DC For Voltage Circuit 0.2VA For Current circuit 0.2VA For Current circuit 3 VA Max 0.5 % of Span < 300mSec. 2KV RMS for 1 Min.( 3KV optional) 5kV 1.2S/50S. > 20M @500V DC 2KV RMS

Ripple Response Time Dielectric Strength Impulse Voltage Insulation resistance o/p Isolation

: : : : : :

INSTALLATION DATA : Mechanical Design : Material of Housing : Mounting : Electrical Connections : Terminal Type : Cross Section of Wire : Weight : 132mm(L) x 80mm(W) x 100mm (H) Top Cover : ABS, Base : Polycarbonate DIN Rail Mounting ( 35 mm) Wall Mount with 2 Screws 12 + 12 with Fixed 6 mm Pitch Cage Clamp 2.5 mm2 380 GMS.

OPERATING CONDITIONS Operating Temp. Storage Temp Humidity : : : 0 oC to +55 oC 20 oC to +70 oC Up to 95 % RH non condensing.

Ordering information for uT Series transducers


Product Type Marking uTXXXX No. Of Phases/ Configuration (X) 1Single Phase 2Three Phase 2 Element (Unbal. Load) 3P2E3W 3Three Phase 3 Element (Unbal. Load) 3P3E4W 4Three Phase 1 Element (Bal Load) 3P1E4W Input Type (X)
1 Voltage Input 2 Current Input

Output Type (X) 1Single Voltage o/p 1Dual Voltage o/p 1Single Current o/p 1Dual Current o/p

Auxilliary Supply (X) 1External Auxilliary Supply 2Self Powered

3Power Factor 4Frequency 5 W(Active Power) 6 VAr(Reactive Power) 7 VA(Apperent Power) 8 DC Voltage 9 DC Current