Protection symbols used in circuit diagrams

-,' ..... ,
t ..... I

Fuse Link - readily separable contact Link - bolted contacts T NC III - O I lIT]O-III -O[]]1 I O /

C o n t r o l o r selector switch Note: the position of the rectangle represents the position in which the circuit is completed between the associated terminals

-tW i O-

- ~ O ~

Link - hinged or sliding Link - plug-in type

[~]
!

Circuit breaker

' -

" >-- Plug and socket


t

Auxiliary switch o r relay contacts -~_ OMake contact Break contact "qD_..A O-- Make contact with delayed make Break contact with delayed break Changeover contact P u s h b u t t o n switches O . O
...at.,

~ "["

Circuit breaker normally open

,~ ~

Withdrawable metal-clad circuit breaker

~/

I
] J I

Switch disconnector

Centre rotating post disconnector

Make contact Break contact

Protection symbols used in circuit diagram,


Telephone type relay contacts Make contact unit I

Single-break disconnector or earth switch Additions to symbol for power-operated disconnector: NA - Non-Automatic A - Automatic Fault throwing switch

I Break contact unit , N~A Changeover (break before make) contact unit Changeover switch break before make

j.

I
'~]

Make contactor

Summation current transformer


Power and voltage transformers

Mechanical coupling ~#~ _ ~ contactor Example - double pole

Two winding

Indirectly-heated bimetallic thermal element _..f3r"v'X._ Operating coil for contactors and relays - general Coil with flag indicator Series coil
Machine windings General and shunt

Simplified form

Auto-transformer

Simplified form - with delta tertiary

Transductor ) c ~ l Spark gap Protective gas d~scharge tube Capacitor

..../'W"V'X._ Series AC generator Motor


C o r e (/./'desired to indicate)

_t-v'v'v-x_ Transformer or reactor winding

Power system protection

Current transformer Current transformerwith tapping ~ ~ Interposingtransformer current or voltage Fixed resistor Variableresistor Resistor,with non-linear current/voltage characteristic Impedance Impedance, with non-linear current/voltage characteristic

Line t~ ~__~ @

cF_r_q~ri_~i-couplingequipment I '

z To carrierequipment

- ~

Fault pn diode or semiconductor rectifyingdiode Zener diode Thyristor

h ~.j

Earthing resistors Dry type pnp transistor

npn transistor Liquid type


t Envelopesmay be omitted

Thermionic valve,triode, indirectly heated Arc suppression coil (~ ]


m

Coldcathode discharge tube (e.g., neon lamp) Coldcathode trigger tube Coaxial line ~ "-q Cablesealing ends

Earth Rectifier

- ~ O I'~ tJ

--~

Protecthgn symbols used in circuit diagrams

+
->-

Rectifier equipment in bridge connection Amplifier

Electromotive force (emf) Private pilot protection Post Office pilot protection

Buchholz - single float Transformer protection Buchholz - two float Winding temperature single switch Winding temperature double switch Biased differential protection Plain balance differential protection Transformer HV connection protection Circulating current Trip flag relay Busbar protection Relay - general symbol Mesh corner protection Feeder protection High speed auto-close relay Power line carrier phase comparison protection Distance protection High speed distance (Mho) protection Overvoltage relay High speed distance (reactance) protection (inverse definite minimum time) Three-pole overcurrent re!a.y (inverse definite minimum time Two-pole overcurrent and single pole earth fault re!ay.se(inverse definite minimum time)

High speed ammeter Alarm flag relay

33_

Electric bell Signal lamp

Powersystemprotection

One-pole overcurrent relay (inverse definite minimum time) Earth-fault relay (inverse definite minimum time) Three-pole two stage overcurrent relay (inverse definite minimum time) Three-pole directional overcurrent relay (inverse definite minimum time) Three-pole overcurrent relay (instantaneous) Three-pole overcurrent relay (extremely inverse definite minimum time) Earth-fault relay (instantaneous) Three-pole high set overcurrent relay Standby earth-fault relay (long time inverse definite minimum time) Two-stage standby earth-fault relay (long time inverse definite minimum time) Reverse power relay Restricted earth-fault relay

7q

Tripping relay

Intertrip relay Intertrip relay (send) Intertrip relay (receive) Definite time relay Negative phase sequence

Lost excitation

Three-pole voltage-controlled overcurrent relay (inverse definite minimum time) Three-pole overcurrent interlocked relay (inverse definite minimum time)

Breaker fail current check

LV connection protection