References
BSC Counter Reference(V900R008C12) BSS KPI Reference(V900R008C12)

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Objectives
Upon completion of this course, you will be able to:
Understand the Measurement Points and Performance Index of handover Analyze, locate and solve handover problems

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Contents
1. Handover Process Flow 2. Measurement Points and Performance Index of Handover 3. Analysis of Handover Problem 4. Handover Cases

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Handover Process Flow


MSC2
Handover judgement4 Search target cell7

MSC1
Inter-MSC H.O 8

BSC1

CGI6

H.O request7

BTS1
Preprocessed MR 3

Channel active 5

BSC2

BTS2

BA2 table1

MS

MR2

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page5

BCCH frequencies of all adjacent cells in BA2 table are sent to MS on system message. MS reports measurement report to BSC. It includes the BCCH , BSIC and signal level of the adjacent cells and serving cells. When the measurement report is preprocessed, BSC identifies the CGI of all adjacent cells through BCCH frequency and BSIC . BSC executes handover judgment flow such as basic cell ranking. Once a proper target cell is found, the handover request message which includes the target cell CGI will be sent to BSC. If the target cell is an internal cell, BSC send the channel active to the BTS. If the target cell is an external cell, both the CGI of the target cell and that of service cell are sent to MSC via the handover required. By matching the CGI of the target cell, MSC searches the target cell. Once the cell is found, MSC will confirm which BSC is belonged to, and send the handover request message to this BSC. If there is no CGI of the target cell in local MSC, MSC will check Adjacent MSC Table" and search the target MSC, then send the handover request message to that MSC.

Contents
1. Handover Process Flow 2. Measurement Points and Performance Index of Handover 3. Analysis of Handover Problem 4. Handover Cases

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Measurement Points of Intra BSC Handover


MS BTS1(target) BSC BTS2 or BTS1(original) Measure Report from MS
CH300: Internal Intra-Cell Handover Requests CH320: Incoming Internal Inter-Cell Handover Requests CH310: Outgoing Internal Inter-Cell Handover Requests

MS

MSC

Channel_Acive Channel_Active_Ack

Handover Command (Old FACCH) Handover Access (New FACCH) Handover_Detect PHYINFO PHYINFO First SABM UA Establish_IND
CH301: Internal Intra-Cell Handover Commands CH321: Incoming Internal Inter-Cell Handover Responses (Incoming Internal Inter-Cell Handovers) CH311: Outgoing Internal Inter-Cell Handover Commands

Handover Complete (New FACCH)

CH303: Successful Internal Intra-Cell Handovers CH323: Successful Incoming Internal Inter-Cell Handovers CH313:Successful Outgoing Internal Inter-Cell Handover

Handover_Performed

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Performance Index of Intra BSC Handover (Cell)


RH303B:Internal Handover Success Ratio per Cell
CH303: Successful Internal CH323: Successful Incoming Internal Inter-Cell Intra-Cell Handovers + Handovers CH300: Internal Intra-Cell Handover Requests

CH320:Incoming Internal Inter-Cell Handover Requests

100

Internal Handover Success Ratio per Cell <= Intra-BSC Radio Handover Success Rate IntraRH303C: Intra-BSC Radio Handover Success Rate
CH303: Successful Internal CH323: Successful Incoming Internal Inter-Cell Intra-Cell Handovers + Handovers CH321:Incoming Internal CH301: Internal Intra-Cell Inter-Cell Handover Handover Commands+ Responses

100

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page8

Difference between " Internal Handover Success Ratio per Cell " and " Intra-BSC IntraRadio Handover Success Rate " : As viewed from formulas, both numerators are success times of handover, while the denominators are different. While viewed from the measurement points of the counter, intra-cell/inter-cell handovers requests >= intra-cell/inter-cell cell handover commands or responses, so Internal Handover Success Ratio per Cell <= Intra-BSC Radio Handover Success Rate. IntraRate In practice: If "Internal Handover Success Ratio per Cell = "Intra-BSC Radio Handover Success Internal IntraCell Rate", this indicates that there is no problem with data, the unsuccessful Rate handovers are caused by radio interfaces, and the radio reasons like interference and coverage should be checked in the first place. If "Internal Handover Success Ratio per Cell < "Intra-BSC Radio Handover Success Internal IntraCell Rate", this indicates that failures may exist in the process from Rate Channel_Activate to "HO-COMD", and there might be data problem or congestion.

Performance Index of Intra BSC Handover (BSC)


ZK3174: Internal Handover Success Ratio per BSC
ZCH303:Successful Internal Intra-Cell Handovers per BSC ZCH323: Successful Internal Incoming Cell Handovers per BSC 100 ZCH300: Internal Intra-Cell ZCH320: Internal Incoming Cell Handover Requests + Handover Requests per per BSC BSC

Internal Handover Success Ratio per BSC <= Radio Handover Success Ratio per BSC
ZK3175: Radio Handover Success Ratio per BSC
ZCH303:Successful Internal Intra-Cell Handovers per BSC

ZCH323: Successful Internal Incoming Cell Handovers per BSC

ZCH301:Internal Intra-Cell Handover Commands per BSC


N

ZK3190:Internal Incoming Cell Handover Commands per BSC

100

Internal Incoming Cell Handover Commands

per BSC Incoming Internal Inter - Cell Handover Responses


i=0

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page9

Measurement Points of Inter-BSC Handover


MS BTS(Original) BSC(Original) MSC BSC(Target) BTS(Target) MS

Measurement Report Measurement Report Handover Required CH330: Outgoing External Handover Request
Inter-Cell Handover Requests CH340:Incoming External Inter-Cell Handover Requests

Channel_Active Channel_Active_ACK Handover_Request_ACK Handover Command


CH331:Outgoing External InterCell Handover Commands CH341:Incoming External Inter-Cell Handover Responses

Handover Access Handover Detect Handover Complete Handover Complete


CH343:Successful Incoming External Inter-Cell Handovers

CH333:Successful Outgoing External Inter-Cell Handovers

Clear Command (HO Successful)

RF Channel Release Clear Complete

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page10

The key measurement points are as follows, same as those of intra BSC handover:
1. After sending "HO-REQUIRED", the original BSC measures "Attempted outgoing inter BSC inter cell handovers". 2. 3. 4. 5.

After receiving "HO-REQUEST", the target BSC measures "Attempted incoming inter BSC handovers". After sending "HO-REQUEST ACK", the target BSC measures "incoming inter BSC handovers". After receiving "HO-Command" , the original BSC measures "outgoing inter BSC handovers". After receiving "HO-Complete", the target BSC measures "Successful incoming inter BSC handover"

6. After receiving "Clear-COM" and the cause value is "HO-Successful", the original BSC measures "Successful outgoing inter BSC inter cell handover".

The difference between "handover times" and "handover request times": Handover times - After "HO-COM" is received or "HO-REQ-ACK" is sent Handover request times - After "HO-REQUIRED" is sent or "HO-REQUEST" is received Therefore, inter BSC inter cell radio handover success rate >= inter BSC inter cell handover success rate.

10

Performance Index of Incoming External Inter-Cell Handover(Cell)


TH343: Success Rate of Incoming External Inter-Cell Handovers CH343:Successful Incoming External Inter-Cell Handovers CH340:Incoming External Inter-Cell Handover Requests

100

Success Rate of Incoming External Inter-Cell Handovers <= InterExternal Incoming Radio Handover Success Ratio per cell
RH303D: External Incoming Radio Handover Success Ratio per cell CH343:Successful Incoming External Inter-Cell Handovers CH341:Incoming External Inter-Cell Handover Responses

100

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page11

11

Performance Index of Incoming External Inter-Cell Handover(BSC)


ZK3178: External Incoming Cell Handover Success Ratio per BSC ZCH343:Successful External Incoming Cell Handovers per BSC ZCH340:External Incoming Cell Handover Requests per BSC

100

External Incoming Cell Handover Success Ratio per BSC <= External Incoming Cell Radio Handover Success Ratio per BSC
ZK3179: External Incoming Cell Radio Handover Success Ratio per BSC ZCH343:Successful External Incoming Cell Handovers per BSC ZK3191:External Incoming Cell Handover Commands per BSC
N

100

External Incoming Cell Handover Commands per BSC Incoming External Inter - Cell Handover Responses
i=0

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page12

12

Performance Index of Outgoing External Inter-Cell Handover(Cell)


TH333: Success Rate of Outgoing External Inter-Cell Handover

CH333: Successful Outgoing External Inter-Cell Handovers CH330:Outgoing External Inter-Cell Handover Requests

100

Success Rate of Outgoing External Inter-Cell Handover <= InterExternal Outgoing Radio Handover Success Ratio per cell
RH303E: External Outgoing Radio Handover Success Ratio per cell

CH333: Successful Outgoing External Inter-Cell Handovers CH331:Outgoing External InterCell Handover Commands

100

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page13

13

Performance Index of Outgoing External Inter-Cell Handover(BSC)


ZK3176: External Outgoing Cell Handover Success Ratio per BSC

ZCH333:Successful External Outgoing Cell Handovers per BSC ZCH330:External Outgoing Cell Handover Requests per BSC

100

External Outgoing Cell Handover Success Ratio per BSC <= External Outgoing Cell Radio Handover Success Ratio per BSC
ZK3177: External Outgoing Cell Radio Handover Success Ratio per BSC

ZCH333:Successful External Outgoing Cell Handovers per BSC ZCH331:External Outgoing Cell Handover Commands per BSC
N

100

External Outgoing Cell Handover Commands per BSC Outgoing External Inter - Cell Handover Commands
i =0

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page14

14

Performance Indices of BSC Overall Handover


ZK3180: Handover Success Ratio per BSC
[(ZCH313: Successful Internal Outgoing Cell Handovers per BSC+ ZCH333:Successful External Outgoing Cell Handovers per BSC )/ (ZCH310: Internal Outgoing Cell Handover Requests per BSC + ZCH330:External Outgoing Cell Handover Requests per BSC )]*100%

Handover Success Ratio per BSC <= Radio Handover Success Ratio per BSC
ZK3181: Radio Handover Success Ratio per BSC
[(ZCH313:Successful Internal Outgoing Cell Handovers per BSC + ZCH333:Successful External Outgoing Cell Handovers per BSC )/ (ZCH311:Internal Outgoing Cell Handover Commands per BSC + ZCH331:External Outgoing Cell Handover Commands per BSC] *100%

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page15

15

Measurement Points of Inter-MSC Handover


MS BSC-A MSC-A
Prepare_HO

MSC-B

VLR-B

BSC-B

MS

HO-Required

Allocate_HO_NUM Send_HO_Report Send_HO_Report_ACK


HO-Request

HO-Command

Prepare_HO_ACK IAI ACM Process_Access_Signalling

HO-Request-ACK

HO-Access
HO-Complete

Clear-Command

Send_End_Signal

Clear-Complete Send_End_Signal_ACK

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page16

Note: Signaling flow of A interface and Abis interface of inter MSC handover is the same as that of intra MSC handover, only the signaling between two MSC is particular for the inter-MSC handover. As shown in above figure the signaling with "MAP" is of the MAP layer, and signaling of A and Abis interfaces are omitted. After receiving "HO-REQUIRED" of BSC-A (the request message includes CGI of the original cell and target cell), if MSC-A finds that LAC of the target cell doesnt belong to this MSC, MSC-A will query the "REMOT LAC Table (including the LAC and route of the adjacent MSC), and send "Prepare-HO" message to MSC-B according to the route. CGI of the target cell and the indicator of whether to allocate the handover number are included in this Prepare-HO message. According to the received "Prepare-HO" message, if the handover number needs allocating, MSC-B will request the local VLR to allocate the handover number. If VLR has the free handover number, the handover number will be sent to MSC-B through "SendHO-Report". If no handover number is needed, proceed to the next step. After SCCP link between MSC-B and BSC-B is established, MSC-B sends "HOREQUEST" to BSC-B. After that, BSC-B activates the target cells channel, and returns "HO-REQUEST ACK" to MSC-B after receiving the channel activation acknowledgement. According to this message, MSC-B sends "Prepare-HO ACK" to MSC-A. MSC-A establishes the route to MSC-B according to the handover number, and sends "Initialize-Address" (IAI) to MSC-B to help the latter to identify which voice channel is reserved for MS. While MSC-B returns "Address-Complete" (ACM) to MSC-A.

16

Contents
1. Handover Process Flow 2. Measurement Points and Performance Index of Handover 3. Analysis of Handover Problem 4. Handover Cases

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page17

17

Analysis of Handover Problem


Types of handover problems Locating handover problem Causes of handover problem

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page18

18

Types of Handover Problems


Types Possible Results
No handover Result in call drop Handover failure Affect the conversation quality, and call drop Frequent handover Affect the conversation quality and increase load of the system

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page19

Frequent handover: Handover in GSM is hard handover, it is meaning, before handover to the new channel, MS must release the original channel firstly. So frequent handover will result in word-loss in handover and break-make of conversation, thus affecting the conversation quality.

19

Method of Locating Handover Problem


Traffic statistics analysis
Handover Failure/Attempt/Success Measurement per BSC Incoming/Outgoing Internal/External Inter-Cell Handover Measurement per Cell GSM Cell to GSM Cell Incoming/Outgoing Handover Measurement Neighbor Cell Level Measurement per Cell

View alarm
Board fault, transmission, clock, etc.

Drive test Signaling analysis


Abis interface, A interface, E interface

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page20

20

Causes of Handover Problem


Coverage Interference Antenna and feeder system BTS hardware Transmission BSC hardware Data Configuration A interface Target cell congestion Cooperation with equipment of other manufacturers

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page21

21

Causes of Handover Problem


Causes
Coverage Interference Antenna and feeder system BTS hardware Transmission BSC hardware Data configuration A interface Target cell congestion H.O between equipment of different manufactures

Types

No H.O

H.O Failure

Frequent H.O

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page22

22

Problem in Coverage and Interference


Coverage
Poor coverage: forest, complicated topography, building direction and indoor coverage Isolated site: no adjacent cell Over shooting: island effect result in no adjacent cell

Interference
MS can not access network or receive any signal.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page23

23

Island Effect Results in Handover Failure


There is no adjacent cell, so handover becomes impossible.

Non-adjacent cell

Adjacent cell N1

Service cell
Non-adjacent cell Adjacent Cell N2 Non-adjacent cell Isolated island resulting from over shooting Adjacent Cell N3

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page24

In isolated cell coverage area, when MS moves towards the cell edge, the signal becomes weaker and weaker, and since there is no adjacent cell available around, handover cannot be triggered, thus call drop will occur.

24

Problem in Antenna and Feeder System


High Voltage Standing Wave Ratio (VSWR) Antenna is not properly installed Antenna is not parallel The azimuth and downtilt are not correct Poor antenna isolation value RF cables, connectors are loose or incorrect

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page25

25

Problem in BTS Hardware


DDPU,DCOM, splitter/combiner failure TRX failure DTMU failure Clock failure Internal communication cable failure

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page26

26

Problem in Transmission and BSC Hardware


Transmission
Transmission is not stable Serious BER in transmission

Fault of BSC Hardware


Clock board: the faulty clock board causes clock inconsistency between base stations.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page27

For BTS clock, BSC clock, and MSC clock, the following standards are used to judge whether they are out of synchronization: MSC: f/f (frequency deviation) 1E-8 BSC/BTS: f/f (frequency deviation) 5E-8 Inaccurate clock will cause that MS cannot decode BSIC of the adjacent cell correctly.

27

Problem in Data Configuration


Unsuitable setting of handover hysteresis and handover priority. Unsuitable setting of P, N value of statistic time Unsuitable frequency and adjacent relationship configured in BA1/BA2 table CGI, BCCH and BSIC in "External Cell Description Table" are different from those in corresponding BSC. The DPC of BSC in MSC "LAI and GCI Table" is incorrect.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page28

For service cell: Outgoing inter cell handover will fail. For illusory target cell: Incoming inter-cell handover will fail, and successful rate of handover = successful rate of radio handover. Notes: CI can not be configured as "FFFF". "Transmitting BS/MS Power Level": If the measurement report preprocess is enabled, this parameter must be set to "Yes".

28

Problem in A Interface and Target Cell


A interface problem
Basically, the insufficient link resource results in the abnormal handover, as well as abnormal communication. Circuit pool numbers are different ,causing the handover failure.

Target cell congestion


The target cell is congested, which causes the handover failure. Then the target cell should be expanded or reduce its traffic .

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page29

29

Problem in Cooperation between manufactures


Handover between equipment of different manufacturers
The signalings at A interface, E interface of the opposite equipment dont matched with our equipment and can not be recognized or supported, which causes the handover failure, such as voice version, handover number, addressing mode (CGI or LAI).

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page30

30

Contents
1. Handover Process Flow 2. Measurement Points and Performance Index of Handover 3. Analysis of Handover Problem 4. Handover Cases

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page31

31

Handover Case 1
Fault Description
A 1800 cell of a dual-band network (all the 1800 cells belong to one BSC), the incoming handover success rate of intra-BSC and inter-BSC are low from the beginning of the service, while the outgoing handover success rate of intra-BSC and inter-BSC are normal.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page32

32

Handover Case 1
Analysis
Register the traffic statistics and analyze whether the low handover success rate is due to the failure of handover from all cells to this cell or from some few cells. If handover fails from some few cells to this cell, check the handover data and confirm whether there is co-channel and co-BSIC problem. If handover fails from all other cells to this cell, check the data of this cell. If data problem is excluded, check the hardware carefully. Check the alarm or perform drive test to locate uplink fault or downlink fault. Check step by step and find out the cause.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page33

33

Handover Case 1
Solution
Register the incoming inter cell handover measurement function and find that the successful rate of handover from all other cells to this cell is low, although it is not always 0 percent. Via careful data checking, confirm that the data of this cell is correct. Perform drive test and find that the downlink signal is normal but almost all handovers to this cell are failure. But near the BTS, the handover is successful occasionally, perhaps the problem is with the uplink signal. Check the uplink channel, antenna, DDPU, there are no problem. Change the TRX, everything is normal.

Conclusion
The symptom is that the uplink and downlink at Um interface are unbalanced so uplink voice quality is bad.
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page34

34

Handover Case 2
Fault Description
A subscriber complains that the signal in a place on his way to office is not good. Call drops occurs several times when he drives his car. The phenomenon is that the conversation is suddenly interrupted. The handset signal bar indicates no signal, and then normal again after several seconds.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page35

35

Handover Case 2
Analysis
Neighbor cell relationship Isolated island effect Geographical factors of buildings and mountains result in the weak signal The signal of a cell suddenly fades drastically due to buildings BTS equipment or intermittent transmission

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page36

The following possibilities can lead to the problem that a call is dropped, that there is no signal during call drop, and that the signal is recovered after several seconds:
The most common possibility is that there is no neighbor cell handover relation, so an MS cannot be handed over to the neighbor cell, hence the call drops. After the call drops, the MS re-selects a cell and resides in a good cell, so the signal is recovered. Isolated island caused by cross-coverage also leads to this problem. When a signal exceeds the coverage, an MS uses the signal even when the MS is far away from the cell that provides the signal, but at this time there is no cell that is a neighbor of the cell. When the cell signal becomes weak, handover is impossible, leading to the call drop. After the call drop, the MS re-selects a good cell and displays signal again. At that place, the signal is indeed too weak to maintain conversation due to geographical factors of buildings and mountains. When an MS goes to that place, call drop occurs. After the MS passes the place, the signal is recovered again. In the urban area where there are many BTSs, this problem does not happen. In the suburb area where only one BTS is used for coverage, this problem sometimes occurs. At that place, due to buildings, the signal of a cell suddenly fades drastically, and the MS has not time to hand over, hence the call drop. After the call drop, the MS resides in a good cell again. Signal is interrupted due to the BTS equipment or intermittent transmission.

36

Handover Case 2
Solution
Via DT, it shows that the signal of several cells is strong and is -70 to -80 dBm, so it is unlikely that the problem is caused by bad signal. We obtain further information from the subscriber and know that the driver at that time drive very fast. Therefore it supposed that this problem may occur under high speed movement. Then perform drive test again under high speed for several times and the call drop recurs.
1 3

A
2 3

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page37

The customer service technicians go to the site to perform drive test and discovers that the road from south to north is covered by the signals from four cells, which are cell1 (northward) of BTS C, cell 3 (southwestward) of BTS B, cell 2 (southeastward) of BTS A, and cell 3 (southwestward) of BTS D. In the complained place the signal of several cells is strong and is -70 to -80 dBm. It is unlikely that the problem is caused by bad signal. The drive test shows that the handover relation is normal. The drive route is such that cell 1 of BTS C is first occupied; then the vehicle drives northward and the MS can hand over to cell 3 of BTS B and cell 2 of BTS A. As the vehicle drives on northward, the MS hands over to cell 3 of BTS D. Multiple drive tests along the road show normal result and the problem complained by the subscriber does not occur. To investigate the problem, we obtain further information from the subscriber and know that the driver at that time drove very fast. Therefore we think this problem may occur under high speed movement. We perform drive test again under high speed for several times and the call drop recurs.

37

Handover Cases 2
Solution
Cell 1 of BTS C is far away from cell 3 of BTS D and the two cells are not defined as neighbor cells. Thus an isolated island is generated, handover cannot be performed, and call drop arises. The special thing about this isolated island effect is that it occurs at high speed. Therefore troubleshooting is difficult. After a neighbor relation is added, this problem is solved. On the other hand, because this problem occurs due to insufficient time to hand over, the handover decision time is reduced so that the handover can happen timely.
1 3

A
2 3

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page38

Cell 1 of BTS C provides coverage along the road and the signal reaches far away. When a vehicle drives very fast, sometimes the MS has not time to hand over to cell 3 of BTS B or cell 2 of BTS A. Cell 1 of BTS C is far away from cell 3 of BTS D and the two cells are not defined as neighbor cells. Thus an isolated island is generated, handover cannot be performed, and call drop arises. The special thing about this isolated island effect is that it occurs at high speed. Therefore troubleshooting is difficult. After a neighbor relation is added, this problem is solved. On the other hand, because this problem occurs due to insufficient time to hand over, the handover decision time is reduced so that the handover can happen timely.

38

Handover Cases 3
Fault Description
This case occurs during the drive test at a new site. Even when the receive level of serving cell B is higher than the receive level of neighboring cell M, handover is triggered from cell B to cell M.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page39

39

Handover Cases 3
Analysis The possible causes of the handover from a cell with a higher level to a cell with a lower level cell are as follows: 1. The PBGT handover threshold for traffic adjustment is lower than 64. 2. The handover is emergency handover due to the heavy load or low quali ty of the original cell with the higher level. 3. The priority of the cell with the higher level is lower than the priority of t he cell with the lower level.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page40

40

Handover Cases 3
Solution Analyze the drive test data and find that the downlink receive quality and l evel of the serving cell are normal. Thus, the handover is not associated wit h the downlink receive quality and level. Check the data configurations and find that the handover due to heavy loa d is disabled. Thus, the handover is not due to heavy load. Check the BSC parameter configurations. The result shows that the thresho ld for the PBGT handover from cell B to cell M is 68 and that the handover hysteresis is 4. Thus, the handover is not PBGT handover.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page41

41

Handover Cases 3
Solution
Check the priority settings of the cells. The result shows that cell B is at level 2 on l ayer 3 and that cell M is at level 1 on layer 3. Check the inter-layer handover threshold and hysteresis. The result shows that the interlayer handover threshold is 20 and that the interlayer handover hysteresis is 5. Thus, when the receive level of cell B is higher than 85 dBm, handover is initiated from cell B to cell M. Modify the priority level of cell B to level 1. In this way, the cells are at the same pr iority level. The handover problem is solved.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page42

42

Handover Cases 4
Fault Description
Suburb of city A, Huawei BTS3012 M-2 cell, incoming handover success rate lower than 70%, number of incoming handover failures at busy hours greater than 35.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page43

43

Handover Cases 4
Analysis
The hardware such as clock board is checked and no problem is found. Register the traffic measurement of the cell incoming handover, it is found that most of the handover failures occur from the external N-1 cell of the BTS of company S. The field drive test shows that in times of handover failure, there occurs a neighbor frequency in the neighbor cell frequency list. It is suspect that the handover failures are caused by downlink inter-frequency interference. We trace and analyze the handover failure signaling and finds that sometimes the handover failures occur when the MS receives the handover command and sends access pulses to the target cell and sometimes the handover failures occur when the MS reports the SABM frame.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page44

44

Handover Cases 4
Solution
Therefore the conclusion is that the MS fails to correctly decode the physical message due to the downlink inter-frequency interference, or the MS fails to receive the UA frame from the target cell, resulting in handover failure. The cell frequency is planned again and is changed from 113 to 121. The problem is solved.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page45

Signaling tracing is very helpful if there are problems in cooperation with other manufacturers equipment.

45

Handover Cases 4
Handling Suggestions
The BTS hardware alarms are checked. The cell incoming handover traffic measurement is registered. Drive test to trace the signaling. The cell frequency is modified. The traffic measurement is checked and it is confirmed that the number of incoming handover failures decreases and the incoming handover success rate reaches 92%.

Suggestion and Summary


The downlink interference is not represented in the interference band and the range affected by the partial downlink interference is small. We may miss the faulty place during the drive test due to selection of the drive route. It is desirable to perform careful drive test on the abnormal cells.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page46

46

Handover Cases 5
Fault Description BSC6000 has very low HO attempt & during many drive test no HO at all. KPI indicate that there is very low HO attempt with good success rate. From Drive test using TEMS, we found out Missing Neighbor Detection message appears in neighbor list when MS still try to make HO to serving cell. And also T200 Expired appears. The figure below and the corresponding KPI statistics table is presented as below.

Corresponding KPI Statistics Table

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page47

47

Handover Cases 5

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page48

48

Handover Cases 5
Analysis Neighbors cell configuration is incorrect Data configuration has some problem, such as NCC Permitted

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page49

49

Handover Cases 5
Solution Compared with other BSC, found out the handover attempts are less than other BSCs even under the same condition. Checked the neighbor cell configuration, for some cells, there were some neighboring cells missing, but after adding, the problem still existed. Checked "NCC permitted" , we found that the configuration in the problem BSC is set to be 1111000, that is, enabling NCC 4~7 handover while disabling NCC0~3, but the neighboring cells' NCC is 0~3. Changed NCC Permitted to be 11111111, the problem is solved.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page50

To solve the problem of low handover attempts, we firstly compared the handover times with other BSCs under the same scenario and found out the attempts are less than other BSCs even under the same condition, in addition, we also checked the neighbor cell configuration to see whether there are enough neighbors to ensure the handover proper and prompt, for some cells, there were some neighboring cells missing, but after adding, the problem still existed, and we checked the parameters, found out There is a parameter "NCC permitted" relative to the low handover times, the definition of this parameter is as follows: NCC permitted Range: 0 allowed~7 allowed Default: 1111111 Description: Network color code permitted. The value 1 stands for permitted and 0 for forbidden. This parameter is sent in system information 2 and 6. When the cell's NCC is consistent with the value of NCC permitted, then this cell will be measured by MS. And MS will report the measurement report to BTS. This parameter consists of one byte (8bit). Each bit is corresponding to an NCC (0~7) and the last bit is corresponding to NCC 0. If bit N is 0, then MS will not measure the cell level with NCC being N. Note:As MS cannot report the adjacent cell information where NCC is set to 0, the incorrect setting of this parameter will cause MS to be unable to hand over during conversation. See Protocol 0508. This parameter can be used to make MS 's measurements on some adjacent cells optionally. We found that the configuration in the problem BSC is set to be 1111000, that is, enabling NCC 4~7 handover, but from the feedback, the neighboring cells' NCC is 0~3.

50

Handover Cases 5
Suggestions and Summary: NCC Permitted parameter is an important parameter to impact on handover but always been neglected, and if the similar phenomenon happened, this is a clue to solve this problem.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page51

51

Handover Cases 6
Fault Description
A GSM network, where one MSC is attached with two BSC, is all configured with Huawei equipment. When the two BSC are cutovered, the successful handover rate from BSC1 to BSC2 is 0, but the opposite is normal. Intra-BSC1 and intra-BSC2 handover are normal.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page52

52

Handover Cases 6
Analysis
Register outgoing inter-cell handover measurement function of BSC1 and incoming inter-cell handover measurement function of BSC2. Check the data related to handover of BSC1 and BSC2. Analyze signaling of handover failure.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page53

53

Handover Cases 6
Solution
Check all data of inter-BSC handover: external cell description data table, BA2 table, CGI of MSC. No problem is found. Trace A interface message of BSC1 and BSC2. After BSC1 sends "HOREQUIRED", BSC2 has not received "HO-REQUEST" message, but opposite is normal. The path of data search: MSC goes to "LAI and GCI Table" according to the CGI of the target cell in "HO-REQUIRED" message, and sends HO request to the correct BSC base on the description of the DPC of the cell given in the table.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page54

54

Handover Cases 6
Solution
The HO-REQUEST message, which should have been sent to BSC2, is sent to BSC1. It is DPC error. After correction, the problem is solved.

Conclusion
For the data of inter-BSC handover, besides checking whether CGI at MSC side is consistent with that of opposite and BSC, check whether the DPC is correct. MSC look up target DPC based on the CGI of the target cell. When the DPC is incorrect, "HO-REQUEST" will be sent to wrong BSC.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page55

55

Handover Cases 7
Fault Description
After all BTSs of a certain BSC32 are swapped to the BSC6000, the PBGT handover proportion decreases from the average value 60% to 40%. The number of bad quality handovers increase. It thinks that the problem is caused by the interference and coverage. Note: The PBGT handover proportion is one of the key indexes that the operator uses to evaluate the network coverage quality. PBGT Handover Proportion = PBGT Handover Requests/Total Handover Requests

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page56

56

Handover Cases 7
Analysis The possible causes of the decrease in the PBGT handover proportion are as follows: The number of other handovers with a higher priority than that of the PBGT handover increases. The possible causes are the interference or coverage problems. The data configurations of PBGT handover change, thus causing an increase in the condition of the PBGT handover and a decrease in the number of PBGT handover attempts. 16-bit value affects the priorities of many neighbor cells with good levels.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page57

(1) The PBGT handover algorithm is used to find a cell that meets the following conditions on a real-time basis and determine whether to perform a handover: The cell has less path loss. The level of the neighbor cell is higher than the threshold for the local cell. The cell meets the system requirements. PBGT Handover Proportion = PBGT Handover Requests/Total Handover Requests (2) The possible causes of the decrease in the PBGT handover proportion are as follows: The number of other handovers with a higher priority than that of the PBGT handover increases. The possible causes are the interference or coverage problems. The system parameters that the PBGT handover requires change, thus causing an increase in the number of requirements for the PBGT handover and a decrease in the number of PBGT handover attempts. (3) The requirements of the PBGT handover are as follows:

The PBGT handover is implemented only between the cells with the same 57 layer and same level.

Handover Cases 7
Solution
The problem may be caused by interference and coverage. Check the related traffic measurement. The traffic indexes of the interference band before and after the swap are low. The BTS hardware is operational. Check the parameters related to the PBGT handover, PBGT Handover Threshold and Decision Time. The parameters of other handovers with higher priories than PBGT handover are proper.

Check the settings of the 16-bit priority. The inter-layer handover threshold and hysteresis are greatly different from those configured on the original BSC. For the existing network, the initial threshold is set to 25 and the hysteresis is set to 3. For the original BSC, the initial threshold is set to 40 and the hysteresis is set to 1.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page58

(1) The problem may be caused by interference and coverage. Check the related traffic measurement. The interference handover proportion before the swap is low. The traffic indexes of the interference band before and after the swap are low. The BTS hardware is operational. The OMC data shows that not all parameters are mapped according to the original network during the swap from the BSC32 to the BSC6000. All BTSs are configured according to the initial template of the BSC6000. (2) Check the parameters related to the PBGT handover, PBGT Handover Threshold and Decision Time. The parameters of the handovers with higher priories than PBGT handover are proper. (3) Check the settings of the 16-bit priority. The inter-layer handover threshold and hysteresis are greatly different from those configured on the original BSC. For the existing network, the initial threshold is set to 25 and the hysteresis is set to 3. For the original BSC, the initial threshold is set to 40 and the hysteresis is set to 1. If the following conditions are met, the priority of the neighbor cell is lower than that of the local cell. Even the level of the neighbor cell is higher than that of the local cell, the PBGT handover fails to be triggered. The threshold for the receiving level is set to 25. The level of the neighbor cell is lower than the value of threshold + hysteresis. The level of the local cell is not lower than the value of threshold - hysteresis. In addition, the sites covered by the BSC are located in the suburb areas. There is a great probability that the receiving level of these sites is 25. Therefore, the settings of 16-bit priority have great impacts on the PBGT handover. After the threshold is set to 40 and the hysteresis is set to 1 in batches on the BSC, the PBGT handover proportion increases to 55%-60%, which is close to the original BSC index value.

58

Handover Cases 7
Suggestion and Summary When analyzing the handover traffic measurement, the impacts of the factors in the handover algorithm on the handover priority and handover triggering conditions should be taken into account. The mapping of all parameters at the cell level is essential to the BSC swap. If parameters are not configured according to the original network, the network indexes may be affected. There are multiple parameters at the cell level.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page59

(1) When analyzing the handover traffic measurement, you need to take the impacts of the factors in the handover algorithm on the handover priority and handover triggering conditions into consideration. (2) The mapping of all parameters at the cell level is essential to the BSC swap. If parameters are not configured according to the original network, the network indexes may be affected. There are multiple parameters at the cell level. Therefore, the workload of analyzing and checking the parameters is large if the indexes related to the traffic measurement have problems.

59

Handover Cases 8
Fault Description
Huawei BTSs belong to Huawei BSC independently are inserted into a GSM900 network. After the cutover, the user complains that Huawei BTS handover is not good and that the BSC outgoing handover success rate is below 85%. The drive test shows that the serving cell is Huawei cell A and that then drive toward cell B. The receiving level of cell A is -80 dBm (no downlink power control), while the receiving level of the neighbor cell B of another BSC is -60 dBm. Handover does not happen until MS passes across the cell B.
No Huawei BSC Huawei BSC

No handover for a long time


-80dBm -60dBm

Huawei Cell A
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Cell B

Page60

60

Handover Cases 8
Analysis The reason that the receiving level of the neighbor cell is strong enough to prevent handover is as follows: The BA2 table has the BCCH frequency of cell B but the handover data, including parameters such as external cell CGI, BCCH, BSIC, and "whether share MSC", are wrong, and "minimum downlink power of the handover candidate cell" is high. Congestion of cell B results in no handover. Other parameters are set incorrectly, resulting in no handover.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page61

61

Handover Cases 8
Solution
Drive test shows that handover does not happen. To verify reasonableness of the data, test MS is used to perform the forced handover. Handover succeeds. The traffic statistic of the no-Huawei BSCs is checked and confirm that there is no congestion in the target cell B. Via drive test, it is found that all the new cells of Huawei BSC have this problem. It is suspected that the problem is caused by a common parameter. The traffic measurement is analyzed and it is found that no PBGT handover happens in the new BSC, while only edge handover happens when the edge handover condition is satisfied, resulting in serious handover delay.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page62

62

Handover Cases 8
Solution
One of PBGT handover condition is target cell must be the first position in the 16bit criterion.If Co-BSC/MSC Adj is set to YES, the cells that do not share BSC/MSC are sorted at the last positions. Therefore the PBGT handover of the BSC outgoing handover does not happen. After Co-BSC/MSC Adj is set to NO, the problem persists. The data is further checked and it is found that the default parameter configuration shows that internal cells of Huawei BSC are "layer 3, priority 1" and the external cells are "layer 3, priority 2". Because PBGT handover only happens at the same layer and the same priority, the default configuration does not trigger PBGT handover. After changing all internal cells priority of Huawei BSC from 1 to 2, it shows that PBGT handover happens by analyzing the traffic measurement. Drive test shows that BSC outgoing handover is not delayed.
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page63

63

Handover Cases 8
Suggestion and Summary
Note that the following two default parameters need to be modified in the BTS and BSC insertion plan
1. Set Co-BSC/MSC Adj to NO 2. If there is no requirement for traffic balance, set the layer and priority of the internal cells and external cells to the same layer and the same priority.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page64

64

Handover Cases 9
Fault Description
The drive test of a network in an office shows that in the drive test in a county, there is a strange phenomenon: when the receiving level of the current serving cell (cell A) is as high as 45 dBm, the call still hands over to a cell (cell B) with low level of 78 dBm. Viewed from geographical location, this place should not be covered by cell B. The frequency planning of the network is tight frequency reuse. Therefore the conversation quality becomes worse after handover.
Handover occur from high level to low level
-45dBm -78dBm Cell B

Cell A

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page65

65

Handover Cases 9
Analysis
There are the following reasons that can lead to handover from a high-level cell to a low-level cell.
To adjust the traffic, the PBGT handover threshold is set to a value less than 64. When emergent handover occurs, such as BQ handover (Because the uplink quality is bad for interference, BQ handover occurs). Though the downlink signal level of the current cell is strong, the uplink signal level is weak and already reaches the handover threshold. The layer and priority of the low-level cell is higher than those of the high-level cell.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page66

66

Handover Cases 9
Solution
1. Check BSC data configuration It is found that the [PBGT HO Threshold]=70 and [Inter-cell HO Hysteresis]=3. Therefore the handover is not a PBGT handover. 2. The drive test data shows that when a handover is triggered, both the downlink receiving quality and the downlink receiving level of MS in the serving cell are good. This excludes handover caused by downlink receiving quality and level.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page67

67

Handover Cases 9
Solution
3. Check the cell priority It is found that cell B is at layer 3 with priority 1 while cell A is at layer 3 with priority 2. [Inter-layer HO Threshold]=25 and [Inter-layer HO Thysteresis]=5. Therefore when the receiving level of cell B is greater than 80 dBm, handover is triggered. The handover is a better cell handover from a cell in a high receiving level to a cell in a low receiving level. In the initial data configuration, the BSC internal cells are designed at layer 3 with priority 1 and the external cells are at layer 3 with priority 2. The engineer ever changed data during routine maintenance. The priority of cell A is changed to 1, and the priority of cell B is changed to 2, the handover becomes normal.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page68

68

Handover Cases 10
Fault Description
Huawei mini BTSs and NT BTSs are in mixtured networking, that is to say, few Huawei BTSs are located in a great many NT BTSs. One day the customer complains that during a drive test, handing over from a Huawei mini BTS to a neighbor cell (NT BTS) is very difficulty, and that the handover request is not sent even when the receiving level of the neighbor cell (NT BTS) is much stronger than that of the serving cell (Huawei mini BTS). Sometimes handover does not happen until the call drop. All the cells are in the same layer and the same priority. [Co-BSC/MSC Adj] is YES. [Inter-layer HO Threshold]=25, and [Inter-layer HO Thysteresis]=3.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page69

69

Handover Cases 10
Analysis
Firstly, suspected that the problem of failure to send handover request is caused by improper neighbor cell relationship of the serving cell or by incorrect frequencies in the BA1 table and BA2 table. The check result shows that the neighbor cell relationship is right and that the frequencies are correct.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page70

70

Handover Cases 10
Analysis
Secondly, Since [Co-BSC/MSC Adj] is set to YES, compare the 16bit value between serving cell and neighbor cell.
Rx_Lev Serving Cell Serving Cell Neighbor Cell Neighbor Cell Neighbor Cell
>= 88 dBm < 88 dBm >= 82 dBm >= 82 dBm < 82 dBm

In the same BSC

14th bit 0 1 0 0 1

13th ~ 12th bit 00 00 00 01 00

10th ~5th bit 0 0 0 0 0

/ / Yes No Yes or No

. All the cells are in the same layer and the same priority, and in the same MSC. . [Co-BSC/MSC Adj] is YES . [Inter-layer HO Threshold]=25(-85dBm), and [Inter-layer HO Thysteresis]=3dB
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page71

Since Co-BSC/MSC Adj is set to YES, of the 16bit sequence number, .If the serving cell level >= inter-layer handover thresholdhysteresis, which is >=88 dBm, bit14 is 0, bits 5~10 of the serving cell are the same as those of the neighbor cell, so bits 12, 13 and 14 are all 0. .If the serving cell level < inter-layer handover thresholdhysteresis, which is < 88 dBm, bit14 is 1, bits 5~10 of the serving cell are the same as those of the neighbor cell, so bits 12 and 13 are 0, and bit 14 is 1. .If neighbor cell level >= inter-layer handover threshold + hysteresis, which is >= 82 dBm, bit 14 is 0, bits 5~10 of the internal cells are the same as those of the serving cell, so bits 12, 13, and 14 of the internal cells are all 0, while bits 5~10 of the external cells are the same as those of the serving cell, so bit 12 is 1, and bits 13 and 14 are 0. .If neighbor cell level < inter-layer handover threshold + hysteresis, which is < 82 dBm, bit 14 is 1, bits 5~10, 12, and 13 are all 0, for both internal cells and external cells. .The actual situation is, when the level of the serving cell is higher than 88 dBm, all the most significant bits of the serving cell are 0. For cells of different BSC, even when the level of the serving cell is higher than 82 dBm, bit 14 is 0. But because bit 12 is 1, the cells of different BSC are still sorted after the serving cell and no normal handover can be initiated (including edge handover, PBGT handover, and inter-layer inter-priority handover). In other words, when Co-BSC/MSC Adj is YES and the vicinity of Huawei BTS is BTSs of different BSCs, if the level of the serving cell is not lower than 88 dBm, handover is very difficult to initiate. .When the level of the serving cell is lower than 88 dBm, bit 14 of the serving cell is 1, bits 5~10, 12, and 13 are 0. If the receiving level of a neighbor cell of different BSC is lower than 82 dBm, bit 14 is 1, bits 5~10, 12, and 13 are 0. In this case all the cells are sorted by the level. If the receiving level of a neighbor cell of different BSC is higher than 82 dBm, bit 14 is 0 and the cell is sorted at the front. That is, if the vicinity of Huawei BTS is BTSs of different BSCs, when the level of the serving cell is lower than 88 dBm, no matter if the level of the neighbor cells is greater than 82 dBm, the cells can be correctly sorted and can initiate normal handover. .Therefore, if a Huawei BTS is randomly distributed among other BSCs and the vicinity is BTSs of other BSCs, it is recommended to set Co-BSC/MSC Adj to NO.

71

Handover Cases 10
Analysis
Thirdly, the geographical environment around the mini BTS is complex and P/N = 5/4s, respectively. These values are large. Therefore sometimes when the MS receiving level is lower than 88 dBm, the level decreases so rapidly due to the complex terrain that call drop happens before handover succeeds. Therefore P/N are changed to 3/2s, respectively. In this case, handover is triggered very quickly at low level.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page72

72

Handover Cases 10
Solution
The handover performance measurement is registered and it is found that the cell has handover request and that the handover success rate is high. The BSC incoming and outgoing handover performance measurement is registered and handover happens normally between the cell and a NT cell. Drive test shows that when serving cell is Huawei mini BTS and the serving level is below 80 dBm, handover does not happen even when the signal of the neighbor cell is much stronger than that of the serving cell. But when the signal of the serving cell is 90 dBm, sometimes handover happens and succeeds, sometimes due to terrain reason, the level decreases so rapidly that handover does not happen in time and result in call drop at last.
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page73

73

Handover Cases 10
Solution
It is confirmed that all the neighbor cells have configured in the BA1/BA2 table and the corresponding frequency is correct. The handover-related parameter setting of the cell is configured to be the same as that of other cells. The parameters that affect inter-BSC cell handover are mainly checked and it is found that [Co-BSC/MSC Adj] is set to YES and that P/N time of the edge handover and PBGT handover are 5s/4s, respectively. The [Co-BSC/MSC Adj] is modified to NO and the P/N time of the edge handover and PBGT handover are changed to 3s/2s, respectively. DT shows that handover happens when the MS receiving level is high.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Page74

74

Thank you