Professional Documents
Culture Documents
5 PEX Pipe, Fittings and Related . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 PEX Pipe Related, ThermoPEX and Central Therm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Manifolds and Water-to-Water Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Water-to-Water Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Connections, Solder and Flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Valves, Manifolds, Strainers, Connections, Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12 Thermostats, Transformers, Aquastats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Baseboards, Copper Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Push-t Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Maintenance, Replacement and Optional Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Maintenance, Replacement and Optional Products - Classic and Pallet Burner . . . . . . . . . . . . . . . . . . 17-18 Maintenance, Replacement and Options Products - E-Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-21 Chimney Components - Classic, E-Classic and Pallet Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-23 Maintenance, Replacement and Optional Products - Maxim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-26 Chimney Components - Maxim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 NUMERICAL PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29 Denitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 SYSTEM DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-38 DIMENSIONS AND MEASUREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 SAMPLE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
All installations must be performed by a qualied installer and in accordance with any and all federal, state/provincial and local codes and regulations. When performing work on an appliance observe all precautions in the literature, tags and labels attached to the appliance and other safety precautions that may apply. When working with electricity and electrical components, failure to follow precautions could result in property damage, personal injury or death.
NOTE
ALPHABETICAL INDEX
1-1/4" Thermostatic Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 1-1/4" Thermostatic Valve Fittings Kit. . . . . . . . . . . . . . . . . . . . . . .11 2-Stage Gas Regulator Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 26 2-Way Zone Valve, 24-Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3/4" Thermostatic Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3/4" Thermostatic Valve Fittings Kit . . . . . . . . . . . . . . . . . . . . . . . .11 3/8" Cleaning Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3-Way Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3-Way Zone Valve, 24-Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 6" Chimney Band Clamp Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 28 6" Chimney Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 28 6" Chimney Guy-Wire Band . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 8" Chimney Band Clamp Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 8" Chimney Base Brace Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 8" Chimney Guy-Wire Band Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 23 8" Spark Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 24-Volt Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13, 25 45 Street Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 48-Bushel Hopper Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 90 Elbow, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 90 Reducing Elbow, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 90 Street Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 14 Adjustable Aquastat, Immersible . . . . . . . . . . . . . . . . . . . . . . . . . 13 Adjustable Aquastat, Surface Mount . . . . . . . . . . . . . . . . . . . . . . 13 Aerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Air Handler Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Air Proving Switch Replacement Kit. . . . . . . . . . . . . . . . . . . . . . . 25 Air Proving Switch Tubing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ash Rake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ash Scoop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Ash Shovel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 21 Ashtrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Automatic Vent Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Auxiliary Auger Kits for Maxim . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Auxiliary Auger Vibrator w/Timer Kit . . . . . . . . . . . . . . . . . . . . . . . 24 Backow Preventer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bag Holder Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Ball Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Baseboard, Complete. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Baseboard Corners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Baseboard End Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Baseboard Joiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Battery Clean Out Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Black Silicone Adhesive, High Temperature . . . . . . . . . . . . . . . . . 16 Blower Fan Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Blower & Motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Brass Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Brass Fittings for 1-1/4" PEX Pipe . . . . . . . . . . . . . . . . . . . . . . . . 12 Brass Hex Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Brass Hose Bib. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Brass Offset Tee, 4" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Brass Pipe Union, FIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Brass Swing Check Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Brass Tee, 3/4" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Burn Chamber Gasket Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Burn Chamber w/Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Burner Auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Burner Auger Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Cam Latch/Cam Loc Bushings with Collar . . . . . . . . . . . . . . . . . . 17 Cast Iron Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Central Boiler Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Central PEX 1/2" Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Central PEX 1" Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Central PEX 1" Pipe Sections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Central Therm Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Central Therm Sleeve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Central Therm Sleeve Dispenser . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chimney Attachment Ring . . . . . . . . . . . . . . . . . . . . . . . . 22, 23, 28 Chimney Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Chimney Support Brace Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Chimney Tee Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Chimney Tee Restrictor Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Cinch Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Clamp Crimp Ring Removal Tool . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Classic Stainless Steel Chimney Sections . . . . . . . . . . . . . . . . . . 22 Cleaning Brush. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Cleaning Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Combustion Fan Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Connector, Straight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Contact Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Copper Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Copper End Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Corner Fan Convector (7k Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Corrosion Inhibitor Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Coupling, Reducing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Coupling, Straight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Decoiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Depth Gauge/Deburring Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Digital Pocket Multimeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Digital Temperature Controller . . . . . . . . . . . . . . . . . . . . . . . . 18, 19 Disconnect Clip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Diverter Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Door Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Door Lock Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Door Seal Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 20 Door Seal Rope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 24 Draft Inducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Drain Coupling, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 E-Classic 1400 Refractory Grates . . . . . . . . . . . . . . . . . . . . . . . . 19 E-Classic 1450 Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 E-Classic 1450 Stainless Steel Chimney Sections. . . . . . . . . . . . 22 E-Classic 2300 Refractory Grates . . . . . . . . . . . . . . . . . . . . . . . . 20 E-Classic 2400 Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 E-Classic 3200 Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 E-Classic Stainless Steel Chimney Section . . . . . . . . . . . . . . . . . 22 Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Fan Center Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Fan Convector (26k Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Female Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Female Adapter, 3/4" Hose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Female Adapter, Copper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Fin Comb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Firebox Temp Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Firebrick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Fittings Kit, Threaded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Fixed Aquastat, 175F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Floor Fan Convector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Flow Check Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Flue Brush & Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 26 Fuse Holder & Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Fuse & Socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Fusion Combustor Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Gas Burner Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Gas Burner Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19, 25 Gas Hose w/Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Gas Ignition Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19, 25 Grate Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Grounding Rod Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Guy-Wire Band. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Heat Exchanger Coil (50k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (80k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (95k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (100k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (125k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (140k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (185k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Coil (220k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heat Exchanger Mounting Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Heat Exchanger Scraper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 HeatTrac Controller Update Kits. . . . . . . . . . . . . . . . . . . . . . . . . . 18 Hex Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 High Limit Switch/Snap Disc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 High Pressure Gas Hose Adapter . . . . . . . . . . . . . . . . . . . . . . . . 26 Hoe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Hopper Extension Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Hopper Lid Shock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Hopper Vibrator Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Hot Filter & Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Ignitor Burner Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ignitor - M250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Ignitor Spark Plug Wire - M250 . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Ignitor Wire Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Indoor Water Temperature Indicator Kit . . . . . . . . . . . . . . . . . . . . 16 Inspection Window Components . . . . . . . . . . . . . . . . . . . . . . . . . 26 Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Isolation Auger Motor Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Isolation Flange Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Isolation Flange with Drain Valve, 3/4" . . . . . . . . . . . . . . . . . . . . . . 5 Kickspace Fan Convector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Latch Spring Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 LED Replacement Bulb/Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 LED Temperature Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Lens & Light Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Light Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Line Voltage Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Linkage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Louvers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Male Adapter, 3/4" Hose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Male Adapter, Copper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Manifold w/o Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Manifold w/Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Manometer Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Maxim Chimney Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Maxim Stainless Steel Chimney Sections . . . . . . . . . . . . . . . . . . 27 Mixing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Monoo Copper Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Multi-stage 24-Volt Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Natural Gas Conversion Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Nipple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 O-Ring Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Panel Radiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 PEX 1-1/4" Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 PEX 90 Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Brass Clamp Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Crimp Rings / Crimp Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 PEX Pipe Cutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PEX Piping Clip Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 PEX Piping Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 PEX Piping Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 PEX Stainless Steel Clamp Crimp Ring . . . . . . . . . . . . . . . . . . . . . 6 PEX Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Photoelectric Eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Pipe Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pipe Plug Wrench Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Plate Heat Exchanger. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Plate Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Plug-in Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Pool Aquastat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Power Supply Cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Programmable 24-Volt Thermostat. . . . . . . . . . . . . . . . . . . . . . . . 13 Propane Shut-off with Level Indicator. . . . . . . . . . . . . . . . . . . . . . 25 Pulse Timer Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Pump Flange Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Pump Wall Mount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Purging and Filling Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Push-t Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Push-t Fittings Water Heater Kit . . . . . . . . . . . . . . . . . . . . . . . . . 15 Ratchet Cinch Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Reaction Chamber Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . 20 Reducer, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Reducing Tee, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Relay Kit, Solid State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Rocker Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Round Pipe Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Secondary Air Charge Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Selector Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Sight Gauge Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Silicone Door Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Single-stage, Non-programmable 24-Volt Thermostat . . . . . . . . . 13 Sludge Conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Snap Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Solder & Soldering Flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Solenoid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Space Heater (100k Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Space Heater (140k Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Space Heater Cabinet (50k Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Spacer Bar Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Stainless Steel Chimney Tee Kits. . . . . . . . . . . . . . . . . . . . . . . . . 22 Suspended Space Heater (100k Btu). . . . . . . . . . . . . . . . . . . . . . . 2 Suspended Space Heater (220k Btu). . . . . . . . . . . . . . . . . . . . . . . 2 Sweat Ball Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Taco Pump Replacement Cartridges . . . . . . . . . . . . . . . . . . . . . . . 5 Taco Pumps - 006 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Taco Pumps - 007 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Taco Pumps - 009 & 014 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 15 Tee, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Temperature Gauge Fitting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Temperature Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Temperature Sensing Wire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Tempering Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ThermoPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ThermoPEX Coupling Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ThermoPEX Termination Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Thermostatic Radiator Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Tile Tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Time Delay Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Turbulator - E-Classic 2300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Turbulator - M175 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Universal Heat Exchanger Mounting Kit. . . . . . . . . . . . . . . . . . . . . 8 Vent Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Vent Cap - Classic Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Vent Elbow, Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wall Mount Fan Convector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Wall Mount Fan Convector (7k Btu) . . . . . . . . . . . . . . . . . . . . . . . . 3 Water Level Float Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 26 Water Softener Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Water Test Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Water-to-Water Heat Exchanger, Double Wall . . . . . . . . . . . . . . . . 9 Water-to-Water Heat Exchanger & Fittings Kit . . . . . . . . . . . . . . . . 9 Water-to-Water Heat Exchanger, Shell & Tube . . . . . . . . . . . . . 8, 9 Wonder Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Y-Strainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
September 2012
Water-to-air heat exchanger coil with 90 3/4" female pipe thread (FPT) outlets. Dimensions: Water-to-air heat exchanger coil with straight 12-3/4" x 14" x 4-1/8". (p/n 107) or 90-degree (p/n 704) 3/4" FPT p/n Description outlets. Used in forced-air furnaces with plenum 287 Heat Exchanger Coil, 50k Btu size from approximately 18" x 18" to 18" x 20". Dimensions: 17-3/4" x 20" x 4-1/8".
Description Heat Exchanger Coil, 125k Btu, straight outlets Heat Exchanger Coil, 125k Btu, 90 outlets
Order the following components for a complete Suspended Space Heater (100k Btu). Some assembly required. Assembled size approximately 19" x 16-1/2" x 16". Allow at least 6" on side for ttings.
p/n 322 323 106 Description Fan Transition Heat Exchanger Coil, 100k Btu
Water-to-air heat exchanger coil with straight 3/4" FPT outlets. Used in forced-air furnaces with plenum size of approximately 20" x 20". Dimensions: 19" x 21" x 4-1/8".
p/n 108 Description Heat Exchanger Coil, 140k Btu
24"
20"
Water-to-air heat exchanger coil with straight 3/4" FPT outlets. Used in forced-air furnaces with plenum size of approximately 23" x 23". Dimensions: 22-3/4" x 24" x 4-1/8".
p/n 110 Description Heat Exchanger Coil, 185k Btu
Order the following components for a complete Suspended Space Heater (220k Btu). Some assembly required. Assembled size approximately 26" x 24" 20". Allow at least 6" on side for ttings.
p/n 111 849 848 851 1280 Description Heat Exchanger Coil, 220k Btu Transition Motor Frame Fan Blades Fan Motor
Water-to-air heat exchanger coil with straight 3/4" FPT outlets. Used in forced-air furnaces with plenum size of approximately 17" x 18". Dimensions: 16-1/2" x 19" x 4-1/8".
p/n 106 Description Heat Exchanger Coil, 100k Btu
The outlet fitting must be located above the inlet fitting.
Outlet Heat Exchanger Outlet
Louvers
Correct Installation
Incorrect Installation
Heat Exchanger Heat Exchanger
Inlet
Fittings Up
Fittings Down
Water-to-air heat exchanger coil with straight 3/4" FPT outlets. Used in forced-air furnaces with plenum size of approximately 24" x 24". Dimensions: 24" x 26" x 4-1/8".
p/n 111 Description Heat Exchanger Coil, 220k Btu
September 2012
Order the following components for a Space Heater (140k Btu). Some assembly required. Assembled size approximately 19" x 21" x 33".
p/n 415 154 108 Description Transition Blower & Motor, 1/4-hp 3-speed fan Heat Exchanger Coil, 140k Btu
Central Boiler fan-forced convector. Quiet operation, integral lters and thermostat connections. 3/4" FPT ttings and on-offthermostat switch. Output up to 26,000 Btu/hr. Color - taupe. 24-Volt Thermostat (p/n 588 or 8200008) is optional.
p/n 1971 588 8200008 956 Description Fan Convector, 26k Btu Programmable 24-Volt Thermostat Non-programmable 24-Volt Thermostat Elbow, 90-degree, 3/4" x 3/4" FPT (optional)
13-1/4"
16"
19-3/4"
Cabinet for housing 1/15-hp Blower & Motor (p/n 203) and 50k Btu Heat Exchanger Coil (p/n 287). Each sold separately. Some assembly required. Dimensions: 16" x 19-3/4" x 13-1/4".
p/n 321 Description Space Heater Cabinet
Replacement air lter (10" x 10" x 1") for fanforced convectors. 1971 convector requires 2 lters; 1910 and 1941 convectors require 1.
p/n 1938 Description Air Filter, 10" x 10" x 1"
Central Boiler recessed wall, fan-forced convector. Quiet operation, integral lters and thermostat connections. Can use Female Adapter (p/n 6679) or Push-t Fitting (p/n 606) for connection. 1/2" ttings and on-off-thermostat switch. Output up to 7,000 Btu/hr. 24-Volt Order the following components for a Space Thermostat (p/n 588 or 8200008) is optional. Heater (100k Btu). Some assembly required. p/n Description Assembled size approximately 19" x 21" x 33". 1941 Fan Convector, Wall Mount,
7k Btu 588 Programmable 24-Volt Thermostat 8200008 Non-programmable 24-Volt Thermostat p/n 416 154 106 Description Transition Blower & Motor, 1/4-hp 3-speed fan Heat Exchanger Coil, 100k Btu
September 2012
18-1/2" 5-1/2"
Myson Lo-Line RC 6-4 wall mount, fan-forced convector with thermostat, output of 4,213-6,531 Two sizes allow multiple applications from 100k Btu Btu/hr. Dimensions: 20-3/16" x 18-1/2" x 5-1/2". to 220k Btu; cabinets are standard with front water Weight: 16 lbs. Fan speed (cfm): boost - 72, access (refer to the chart below for specic medium - 51, normal - 58. applications). NOTE: Blower & Motor and Heat p/n Description Exchanger Coil are sold separately. Air Handler 6776 Myson Lo-Line RC 6-4 Fan Convector Cabinet door is capable of holding a lter (not included). Some assembly will be required. If utilizing Wall Mount Fan Convector an existing 24-volt thermostat to control blower, a Fan Center Relay (p/n 515) must be used.
Heat Exch. Blower Water p/n Dimensions (in.) Coil Range & Motor Access 301 36 x 20 x 23 100k-140k Btu 1/4-hp Front Filter (not included): 16 x 20 303 39 x 25 x 28 185k-220k Btu 1-hp Front Filter (not included): 20 x 20 p/n Description 301 Air Handler Cabinet, 100k-140k Btu, front access 3822 Kit for 301 - back water access 303 Air Handler Cabinet, 185k-220k Btu, front access 3825 Kit for 303 - back water access
Myson Hi-Line HL 7-4 wall mount, fan-forced convector, output of 4,377-7,851 Btu/hr. Dimensions: 20-5/8" x 14-1/4" x 5". Weight: 22 lbs. Fan speed (cfm): boost - 78, medium - 62, normal - 48.
p/n 6777 Description Myson Hi-Line HL 7-4 Fan Convector
Myson Whispa III Kickspace 9000 fan-forced convector, output of 7,634-9,949 Btu/hr. Myson Slim-Line RC wall mount, fan-forced Dimensions: 17-3/4" x 16" x 3-1/2". Weight: 12 convector with remote control, output of 11,882- lbs. Fan speed (cfm): boost - 124, normal - 82. 15,293 Btu/hr. Dimensions: 15-9/16" x 31-7/8" x Cover grill is 4" x 22-1/2". 6-11/16". Weight: 37 lbs. Fan speed (cfm): boost p/n Description - 136, medium - 127, normal - 96. 6773 Myson Whispa II Kickspace 9000 Fan Convector
p/n 6778 Description Myson Slim-Line RC Fan Convector
September 2012
May be used to wire pumps when installed on furnaces. Includes strain relief.
p/n 556 Description Power Supply Cord, 32"
Taco 006 Bronze Circulation Pump for domestic Includes ange, nuts and bolts. O-Ring Set water systems. No ange required, 3/4" sweat p/n Description connection. Power Supply Cord (p/n 556) sold Set of two replacement O-rings for pump ange. 226 Isolation Flange with Drain Valve, 3/4" separately. p/n Description
542 O-Ring Set size 006 p/n 175 hp 1/40 Amp 0.52 Watt 59.8 Head Volume (ft) (gal/min) 9 10
Replacement cartridges for Taco 006, 007, 009, 011 and 014 series pumps. Each includes a 3-year warranty. Taco 007 Circulation Pump requires ange kit (not included). Includes O-rings. Power Supply Cord (p/n 556) sold separately.
size 007 007 Priority p/n 171 413 hp 1/25 1/25 Amp 0.70 0.70 Watt 80.50 81.65 Head Volume (ft) (gal/min) 11 20 11 20 p/n 222 170 172 219 179 Application Replacement Cartridge, 006 Series Pumps Replacement Cartridge, 007 Series Pumps Replacement Cartridge, 009 Series Pumps Replacement Cartridge, 011 Series Pumps Replacement Cartridge, 014 Series Pumps
Taco 009 and Taco 014 Circulation Pumps both require ange kit (not included). Includes O-rings. Power Supply Cord (p/n 556) sold separately.
size 009 014 p/n 173 176 hp 1/8 1/8 Amp 1.40 1.55 Watt 161 178 Head Volume (ft) (gal/min) 34 8 22 32
September 2012
High-density, oxygen barrier, cross-link pipe. Rated for temperatures to 180F at 100 psi. Available in rolls up to 1000 ft long. Excellent for radiant oor heating applications.
p/n 1320 1321 1322 Description Central PEX 1/2" Pipe, 300' Central PEX 1/2" Pipe, 500' Central PEX 1/2" Pipe, 1000'
PEX Adapter
For adapting threaded pipe to Central PEX pipe.
Cinch Tool
Description PEX Adapter, 1/2" PEX x 1/2" MIP ttings PEX Adapter, 1/2" PEX x 3/4" MIP ttings PEX Adapter, 1" PEX x 3/4" MIP ttings PEX Adapter, 1" PEX x 1" MIP ttings
Tool for cinching 1" and 1/2" PEX Stainless Steel Clamp Crimp Rings to PEX pipe. Not for use with any other application.
p/n 5925 Description Cinch Tool
rated
for
PEX Adapter
For adapting copper pipe to Central PEX pipe.
p/n 1337 1331 1348 Description PEX Adapter, 1/2" PEX x 1/2" sweat ttings PEX Adapter, 1" PEX x 1" sweat ttings PEX Adapter, 1/2" PEX x 1/2" FIP ttings
PEX Crimp Ring for PEX pipe. Crimp Tool (p/n 324) required for 1/2" crimp ring. Crimp Tool (p/n 145) required for 1" crimp ring.
p/n 1342 1335 324 145 Description PEX Crimp Ring, 1/2" PEX Crimp Ring, 1" Crimp Ring Tool, 1/2" Crimp Ring Tool, 1"
1302
10 ft.
Female Adapter
Adapts 1/2" copper pipe to 1/2" Central PEX pipe. Sweat end ts over copper pipe.
p/n 6679 Description Female Adapter, 1/2" barb x 1/2" sweat ttings
PEX 90 Elbow
Compact, easy-to-use Ratchet Cinch Tool For coupling two Central PEX pipe ends comes with handy carrying case and calibrating device. For use with 5927 and 5926 crimp rings. together.
p/n 1340 1334 Description PEX 90 Elbow, Brass, 1/2" PEX 90 Elbow, Brass, 1" p/n 4472 Description Ratchet Cinch Tool
PEX Tee
For use with Central PEX pipe. Install with Cinch Tool (p/n 5925) or Ratchet Cinch Tool (p/n 4472).
p/n 5927 5926 Description PEX Stainless Steel Clamp Crimp Ring, 1/2" PEX Stainless Steel Clamp Crimp Ring, 1"
September 2012
Slips over Central Therm Insulation to keep it dry and increase heat transfer efciency, especially Used to remove PEX stainless steel clamp crimp ThermoPEX is exible pre-insulated piping in the spring when ground water is high. Available consisting of two waterproof oxygen barrier PEX in lengths from 100 to 800 feet. rings (p/n 5927 and 5926). lines (supply and return) protected by Description p/n Description polyurethane closed cell foam insulation and a p/n 524 Central Therm Sleeve, 100' 104 Clamp Crimp Ring Removal Tool thick, durable, waterproof polyethylene outer 525 Central Therm Sleeve, 200' Central Therm Sleeve, 300' jacket. It is the ideal insulated piping for use with 526 527 Central Therm Sleeve, 500' outdoor wood furnaces. Available with 1" Central 672 Central Therm Sleeve, 800' PEX Piping Mounting Kit PEX in 100-ft or 800-ft rolls, or with 1-1/4" PEX in 100-ft or 300-ft rolls.
p/n 2441 2491 2799 2492 Description ThermoPEX, 1", 100' Roll ThermoPEX, 1", 800' Roll ThermoPEX, 1-1/4", 100' Roll ThermoPEX, 1-1/4", 300' Roll
Used to secure 1" PEX or copper pipe. Includes base, top bracket and two screws.
p/n 1360 Description PEX Piping Mounting Kit
Th erm oP EX
PEX Hanger
Half-moon, nail-in PEX Hanger for securing PEX piping. Available in two sizes. Closed-cell, green polyethylene Central Therm Insulation for insulating water lines. Available in p/n Description 293 PEX Hanger, 1/2" either 8-ft or 4-ft lengths.
295 PEX Hanger, 1" p/n 241 242 Description Central Therm Insulation, 8' Central Therm Insulation, 4'
September 2012
MPN Units*
Approximate Btu 80-120k 150-200k 250-320k 280-360k Typical Application Hot tubs & pools up to 12,000 gallons Pools up to approx. 30,000 gallons Pools up to approx. 50,000 gallons Pools up to approx. 60,000 gallons
For use with 1/2" PEX pipe in radiant oor installations. Available in a 2- or 3-loop conguration. Manifold ttings are 1" copper sweat; valve tttings are 1/2" barbed.
p/n 1349 1329 376 Description Manifold w/Valves, 2-Loop Manifold w/Valves, 3-Loop Copper Cap, 1"
128 129
Used in hydronic heating to prevent ghost ow when the components are above the manifold. Can be installed horizontally or vertically.
p/n 201 Description Flow Check Valve, 1" threaded
p/n Description 5738 Plate Exchanger, MPN 5 x 12-10, 1" Port 5842 Plate Exchanger, MPN 5 x 12-24, 1-1/4" Port 128 Plate Exchanger, MPN 5 x 12-40, 1-1/4" Port 129 Plate Exchanger, MPN 5 x 12-50, 1-1/4" Port *MPN units are not recommended for use with salt chlorinated pools or hot tubs.
For use with 1/2" PEX pipe in radiant oor Used to mount most 5" x 12" Plate Heat installations. Available in a 2- or 3-loop Exchangers (30 or less) with mounting studs to conguration. Manifold ttings are 1" copper a wall or similar surface. sweat; valve tttings are 1/2" barbed. Does not p/n Description include valves or caps. 5807-011 Plate Mounting Bracket
p/n 1880 1885 Description Manifold w/o Valves, 2-Loop Manifold w/o Valves, 3-Loop
The Plate Heat Exchanger is a compact, highperformance, water-to-water, continuous ow heat exchanger with MPT ports. Units are 316L stainless, copper-brazed. MPN units include mounting studs and are marine-grade stainless, nickel-brazed (for use with pools and hot tubs).
p/n 5734 5744 5636 5637 5635 p/n 5734 5744 5636 5637 5634 5635 Typical Application Water heaters Boilers up to 100k Btu Boilers 100k-175k Btu Boilers 175k-250k Btu Large commercial Description Plate Exchanger, 5 x 12-6, 3/4" Port Plate Exchanger, 5 x 12-30, 1" Port Plate Exchanger, 5 x 12-50, 1-1/4" Port Plate Exchanger, 5 x 12-70, 1-1/4" Port Plate Exchanger, 10 x 20-40, 1-1/2" Port Plate Exchanger, 10 x 20-50, 2" Port
p/n 1097
September 2012
WATER-TO-WATER EXCHANGERS
Water-to-Water Heat Exchanger, Shell & Tube Water-to-Water Heat Exchanger & Fittings Kit Panel Radiators
A water-to-water, continuous-ow heat exchanger used mainly for boiler applications. Side ports are 3/4" FIP; end ports are 1-1/2" FIP.
p/n 151 Description Water-to-Water Heat Exchanger, Shell & Tube, 60"
605
604
Type 21G Double Panel Single Convector and Type 22G Double Convector panel radiators in Install on existing domestic water heater for various sizes and Btu output. Valves (p/n 604, thermal circulating heat transfer. Side ports and 605 are sold separately). end ports are 3/4" FIP. Fittings Kit is sold A water-to-water, continuous-ow heat separately. p/n Baseboard Output Fan Convector exchanger for commercial water heater Equivalent (Btu/hr) Equivalent Description applications. Side ports are 3/4" FIP; end ports p/n 591 Water-to-Water Heat Exchanger, 40" 600 6 feet 3,100 N/A are 1-1/2" FIP. 2053 Fittings Kit
p/n 148 Description Water-to-Water Heat Exchanger, Shell & Tube, 27" 601 602 603 10 feet 14 feet 18 feet 5,000 7,200 10,000 6777, 6774, 6839 6776, 6780 6779, 6773
No electricity required, no thermostats, no extra pumps Easy installation - includes mounting bracket and thread sealer
Description Panel Radiator, 32" x 16" Panel Radiator, 35-1/2" x 24" Panel Radiator, 51-1/2" x 24" Panel Radiator, 55-1/4" x 24"
A water-to-water, continuous-ow heat exchanger used mainly for boiler applications. Side ports are 1" FIP; end ports are 1-1/2" FIP.
p/n 177 Description Heat Exchanger, Water-to-Water, Shell & Tube, 48"
Always use the Shell & Tube Heat Exchangers (p/n 148, 151 or 177) when heating "salt chlorinated" pools and hot tubs. Install Plate Heat Exchangers (MPN units) for standard chlorinated pools and hot tubs. See your dealer for more information.
605
Each valve body is threaded for nominal iron pipe threads and also comes with a compression nut and ferrule.
p/n 604 605 Description TRV II Valve Body and Head, 1/2" Vertical LKD Valve Body with No Cap, 1/2" Preset Flow Rate
September 2012
Low melting-point solder for easier soldering. Soldering ux includes brush. Use for easier Used to remove and install 1-1/4" and 3/4" pipe soldering of copper sweat ttings. plugs. Large end is for 1-1/4"; small end ts 3/4" p/n Description pipe plugs. 1325 Solder
100 Soldering Flux (6 oz) p/n 5459 Description Pipe Plug Wrench Set
Diverter Tee
Extra-heavy male pipe thread (MPT) nipples. Nipple (p/n 118) is used with pumps and ball The diverter tee is an excellent sweat tting used valves. Brass nipples must be used on stainless mainly with fan-forced heaters. steel furnaces.
p/n 118 409 314 533 534 535 536 11157 5000015 Description Nipple, 3/4" x close Nipple, 1-1/4" x close Nipple, 1-1/2" x close Nipple, 3/4" x 2" Nipple, 3/4" x 7" Nipple, Brass, 3/4" x 2" Nipple, Brass, 3/4" x 7" Nipple, Schedule 80, Black, 1-1/4" x 3" Nipple, Schedule 80, Black, 1-1/4" x 2-1/2" p/n 6782 Description Diverter Tee, 1" x 1" x 1/2"
Hex Bushing
Hex bushing with national pipe threads (NPT).
p/n 388 105 412 325 180 408 Description Hex Bushing, 1-1/4" x 3/4" Hex Bushing, 1-1/2" x 3/4" Hex Bushing, 1-1/4" x 1/2" Hex Bushing, 3/4" x 1/2" Hex Bushing, 3/4" x 1/8" Hex Bushing, 1-1/2" x 1-1/4"
Brass hose bib, 3/4" MPT. Use brass cap (p/n 5348) with washer (p/n 5349) to cover end.
p/n 199 5349 5348 Description Brass Hose Bib, 3/4" MPT Washer, 3/4" Cap, Brass, 3/4"
45 Street Elbow
NPT 45 Street Elbow (black).
p/n Description 124 45 Street Elbow, 3/4" 5000017 45 Street Elbow, 1-1/4"
Black Tee (p/n 133) can be used for vent option Suggested for use with plate-style heat near pump. Brass Tee (p/n 3850) can be used in exchanger installations. domestic water situations. Black Tee (p/n 418) 90 Street Elbow in different sizes. can be used to install 1-1/4" thermostatic valve. p/n Description
5907 5908 5909 Brass Pipe Union, 3/4" Brass Pipe Union, 1" Brass Pipe Union, 1-1/4" p/n 133 3850 418 Description Tee, Black, 3/4" NPT Tee, Brass, 3/4" NPT Tee, Black, 1-1/4" NPT p/n 411 274 126 Description 90 Street Elbow, 1-1/4" 90 Street Elbow, 3/4" 90 Street Elbow, Brass, 3/4"
90 Elbow
Brass Tee, 3/4" male x female x male. Mainly 90 Elbow with female threads. used for installing heat exchanger on water p/n Description heater when push-t ttings are used. 956 90 Elbow, 3/4" x 3/4" FPT
p/n 9624 Description Tee, Brass, 3/4" 5000016 90 Elbow, Black, 1-1/4"
10
September 2012
Brass FIP Ball Valve. The 3/4" Full Port Ball Valve (p/n 198) is used on both sides of the pump and on the furnace for each water line.
p/n 186 198 410 Description Ball Valve, 1/2" Ball Valve, 3/4" Full Port Ball Valve, 1-1/4"
Manifold features 1-1/4" inlet and four 3/4" outlets. Manifold measures 3-1/4" x 3-1/4" x 121/4". For 1-1/4" Thermostatic Valve (p/n 1621).
p/n 1624 Description 1-1/4" NPT Thermostatic Valve Fittings Kit p/n Description 1200033-011 Manifold, 1-1/4" Inlet x (4) 3/4" Outlets
Manifold
3-Way Valve
Thermostatic Valve prevents the water Manually operated, FIP, brass 3-Way Valve. temperature from dropping below the optimal p/n Description operating temperature. 330 3-Way Valve, Brass 3/4" FIP
p/n 2500024 1365-011 Description 3/4" NPT Thermostatic Valve Kit Mounting Bracket for 3/4" NPT Thermostatic Valve
Manifold features 1-1/4" inlet and four 1-1/4" outlets. Manifold measures 3-1/4" x 3-1/4" x 19".
p/n Description 1200034-011 Manifold, 1-14" Inlet x (4) 1-1/4" Outlets
Y-Strainer
Brass Swing Check Valve with FIP ttings prevents reverse circulation. Y-Strainer with 0.20 mesh and FIP ttings. p/n Description Recommended when installing plate-style heat 296 Brass Swing Check Valve, 3/4" exchangers. For 3/4" Y-Strainer, use 1/2" Brass 5871 Brass Swing Check Valve, 1-1/4" Pipe Plug (p/n 6557) for cleanout port. For 1" Y-Strainer, use 3/4" Brass Pipe Plug (p/n 574) for cleanout port.
Description Y-Strainer, 3/4" Brass Y-Strainer, 1" Brass Y-Strainer, 1-1/4" Black
Cast Iron Manifold features 1-1/2" FIP inlet and four 3/4" FIP outlets.
p/n 407 Description Cast Iron Manifold
Manifold
Hot Filter (#10) with cartridge, 3/4" FIP ttings. Manifold features two 1-1/4" ttings, six 3/4" FIP ttings and two 1-1/4" bungs (one at each end) Thermostatic Valve prevents the water for large building system. Manifold measures 3" temperature from dropping below the optimal x 3" x 33-1/2". operating temperature.
p/n Description 1621 1-1/4" NPT Thermostatic Valve 1370-011 Mounting Bracket for 1-1/4" NPT Thermostatic Valve p/n 395 Description Manifold p/n 101 202 Description Hot Filter, 3/4" FIP Cartridge, #10
September 2012
11
Brass ttings for 1-1/4" PEX pipe. To ease installation, it is recommended that a heat gun be used on the 1-1/4" PEX pipe.
p/n 380 381 382 Description Male Adapter, 1-1/4" barb x 1-1/4" MIP Brass Coupling, 1-1/4" barb x 1-1/4" barb Brass Elbow, 1-1/4" barb x 1-1/4" barb
Backow Preventer
water
supplies
from
p/n 4928 Description Brass Adapter, 3/4" female hose x 3/4" male pipe
p/n 4929
12
September 2012
24-Volt Transformer
80
OFF
Line Voltage Thermostat (120-volt) used to start Used with 24-volt wall thermostat and 24-volt zone valves. the fan on forced-air systems. Designed specically for water heaters, with a p/n Description temperature range of 90F - 130F. p/n Description
1267 Line Voltage Thermostat 188 24-Volt Transformer p/n 326 620 Description Water Heater Mixing Valve, 3/4" NPT ttings Water Heater Mixing Valve, Low Lead, 3/4" sweat ttings* *Required in CA, VT and MD.
Used to bypass water for radiant oor heat, Can be used in conjunction with zone valves, baseboard heat, swimming pool heaters, etc. zone pumps and forced-air systems or used to (requires 24-volt transformer). operate 24-volt 3-way zone valves (requires 24p/n Description volt transformer). 114 3-Way Zone Valve, 24-Volt, 1" sweat ttings
p/n 588 Description Programmable 24-Volt Thermostat 127 113 3-Way Zone Valve, 24-Volt, 3/4" sweat ttings Replacement Head
Used to bypass water for radiant oor heat, baseboard heat, swimming pool heaters, etc. Can be used in conjunction with zone valves, (requires 24-volt transformer). zone pumps and forced-air systems or used to p/n Description operate 24-volt 3-way zone valves (requires 24- 671 2-Way Zone Valve, 24-Volt, 1" sweat ttings 571 2-Way Zone Valve, 24-Volt, 3/4" sweat ttings volt transformer).
p/n Description 8200008 Non-programmable 24-Volt Thermostat 113 Replacement Head
Plug-in Thermostat
0F
Pool Aquastat
For controlling water temperature in pools, spas, etc., Immersible, temperature range of 40-180F in one-degree differential. With pool or hot tub application, it is recommended to use a stainless steel well (p/n 1248), sold separately.
p/n 191 1247 1248 Description Pool Aquastat, 1/2" NPT tting Well, 1/2" NPT tting Well, SS, 1/2" NPT tting
Tempering Valve
Adjustable between 110-240F, immersible, with 1/2" MPT ttings on well (either close on rise or open on rise). Recommended operating setting is between 165-195F.
p/n 169 Description Adjustable Aquastat
For 1992 and older Classic outdoor wood furnaces, adjustable from 100-240F.
p/n 204 Description Adjustable Aquastat
For controlling water temperature in various types of radiant heat systems. Temperature range 70F -180F (except p/n 306, range 70F - 145F). These are not anti-scald valves and are not intended to be used on water heaters.
p/n 306 327 329 Description Radiant Mixing Valve, 1/2" NPT ttings Radiant Mixing Valve, 3/4" NPT ttings Radiant Mixing Valve, 1" NPT ttings
September 2012
13
Description Copper Coupling, 3/4" sweat x 3/4" sweat ttings Copper Coupling, 1" sweat x 1" sweat ttings
Description Vent Elbow, 3/4" x 3/4" sweat ttings Vent Elbow, 1" x 1" sweat ttings
Baseboard, Complete
p/n 116 120 Description Male Adapter, 3/4" sweat x 3/4" MIP ttings Male Adapter, 1" sweat x 1" MPT ttings p/n 373 Description Drain Coupling, Copper Pipe, 3/4" x 3/4" sweat ttings
Each baseboard includes heating element and cover. Rated 610 Btu/ft at 180F water temperature. Flow rate of 4 gal/min, 3/4" copper sweat ttings. End caps, joiners and corners sold separately.
p/n 234 235 236 237 238 Description Baseboard, Complete, 2' Baseboard, Complete, 3' Baseboard, Complete, 4' Baseboard, Complete, 5' Baseboard, Complete, 6'
Description Female Adapter, 1" sweat x 3/4" FIP ttings Female Adapter, 3/4" sweat x 3/4" FIP ttings
Reducer, Copper
Tee, Copper
p/n 231
Left or right Baseboard End Caps for radiant baseboard water heater.
p/n 232 233 Description Baseboard End Cap, Left Baseboard End Cap, Right
90 Elbow, Copper
Baseboard Corners
p/n 178
Description 90 Elbow, Copper Pipe, 3/4" x 3/4" sweat ttings 90 Elbow, Copper Pipe, 1" x 1" sweat ttings
Inside and outside Baseboard Corner covers for radiant baseboard water heater.
p/n 182 183 Description Baseboard Corner, Inside Baseboard Corner, Outside p/n 376
90 street elbow with 1" female sweat tting on one end and 1" male sweat tting on the other.
p/n 103 Description Street Elbow, 1"
p/n 200
14
September 2012
PUSH-FIT FITTINGS
Push-t Fittings are designed to simplify pipe installation. The ttings allow the user to connect pipe in seconds with relative ease. Instant push-t connection for increased ease-of-use. No soldering, clamps, unions or glue required. Fits copper tubing and PEX piping and connects in any combination.
Push-t Fittings
Connector, Straight
Disconnect Clip
p/n 9264
Elbow
Coupling, Straight
p/n 613 9265 p/n 606 607 608 Description Coupling, Straight, 1/2" x 1/2" Coupling, Straight, 3/4" x 3/4" Coupling, Straight, 1" x 1"
Tee
Coupling, Reducing
p/n 614 Description Tee, 1" x 1" x 1"
p/n 609
Install on existing domestic water heater for thermal circulating heat transfer. Water-to-water heat exchanger is sold separately.
p/n 9263 Description Push-t Fittings Water Heater Kit
Connector, Straight
1/8" MPT Temperature Gauge (p/n 6054) installs on Temperature Gauge Fitting and tting installs on push-t tting Tee (p/n 614).
p/n 610 611 Description Connector, Straight, 1/2" x 1/2" FNPT Connector, Straight, 1" x 1" FNPT p/n 1350 Description Temperature Gauge Fitting, 1" Push-t x 1/8" NPT
Connector, Straight
p/n 612
Deburs pipe and used to mark pipe to indicate when the pipe is inserted completely into the tting. One tool for 1/2", 3/4" and 1" pipe.
p/n 615 Description Depth Gauge/Deburring Tool
September 2012
15
For single use in lling water jacket, Water Recommended for taping Central Therm Softener Cartridge has 5,000 grains of removal Insulation joints after gluing with contact cement. capacity. For average water with 10 grains p/n Description hardness, will treat 500 gallons water. May also Water Test Kits and replacement items for testing 251 Tile Tape, roll be connected together to increase removal your furnace water. Complete kits include pH test strips. capacity.
p/n 1310 Description Water Softener Cartridge p/n 405 597 153 403 404 Description Water Test Kit, Complete Water Test Kit, Complete, Anti-Freeze Compatible Litmus Paper Permanganate Sulfuric Acid
16
50
XL
Decoiler
Corrosion Inhibitor plus Polymer Solution helps protect exchangers and pumps against solids adhering to system parts. Refer to chart below for amounts used in each model furnace.
Models CL 4030 CL 5036 CL 6048 E-Classic 3200 E-Classic 2400 E-Classic 2300 E-Classic 1450 E-Classic 1400 Pallet Burner CL 7260 Maxim M175, M250 p/n 1650 Description Corrosion Inhibitor Plus Corrosion Inhibitor Amount 3/4 unit 1 unit 2 units 2 units 1-3/4 units 2-1/2 units 1 unit 1 unit 3 units 4 units 1/2 unit
Temperature Gauges
1"
12 80 40 0
6054
174 4"
Remote inline monitoring of water temperature (battery operated). Includes LCD, 75 feet of cord and probe. Dip switch can be set to either Fahrenheit or Celsius. NOTE: Black Tee (p/n 133) and Hex Bushing (p/n 180) are not included with the kit.
p/n 5052 133 180 Description Indoor Water Temperature Indicator Kit Tee, Black, 3/4" NPT Hex Bushing, 3/4" x 1/8"
Sludge Conditioner
In-line, dial temperature gauge with 1/2" MPT (p/n 174) is optional for manifold, pool heater systems, etc. Gauge (p/n 6054) is 1/8" MPT, 1" diameter with 1" stem length, for use in tight areas.
p/n 6054 174 Description Temp. Gauge, 1/8" MPT Temp. Gauge, 1/2" MPT
NOTE: Sludge Conditioner should be used if the Temperature water quality is known to contain higher concentrations of minerals or solids. It is best to use softened water instead. If a furnace has been subjected to low Corrosion Inhibitor levels and corrosion is evident in the water jacket, Sludge 100% silicone adhesive. Conditioner can be used to help clean some of the p/n Description corrosion from inside the water jacket before 806 Black Silicone Adhesive, High Temperature, 10.1 ushing and relling. oz
The Fan Center Relay is used to control a 110volt fan with a 24-volt thermostat.
p/n 515 Description Fan Center Relay
Fin Comb
Reduces mineral deposits in boiler side of waterto-water heat exchangers. Refer to chart below for amounts used in each model furnace.
Sludge Models Conditioner Amount CL 4030 1/2 gal. CL 5036, CL 6048 1 gal. CL 7260, Pallet Burner 2 gal. p/n 166 Description Sludge Conditioner, 1 gal.
Tool with six interchangeable heads for straightening ns on water-to-air heat exchangers. For all units with 8, 9, 10, 11, 12 and 14 ns per inch.
p/n 5918 Description Fin Comb
16
September 2012
Sold either by the foot or in pre-cut lengths for specic model applications. Silicone is not Used as a rebox maintenance tool, hoe comes Sight Gauge Components replace original included. with metal handle. components.
p/n 308 Description Hoe p/n 812 5032 846 880 6146 Description Sight Gauge Tube, 9/16" OD x 3/8" ID Clip Valve, 1/4" Elbow, 1/4" Dust Cap p/n 7674 7594 359 360 361 367 Description Rope, 7/8", priced per ft Door Seal Rope, 1", priced per ft Door Seal Rope, 7/8", 8' for CL 4030, 5036 Door Seal Rope, 7/8", 9' for CL 6048 Door Seal Rope, 1", 12' for CL 7260 Door Seal Rope, 1", 23' for Pallet Burner
Ash Shovel
Linkage
Ash Rake
Linkage between the solenoid and damper control. Each linkage comes complete with Kit includes Door Seal Rope cut to length and Black Silicone Adhesive. cotter pins.
p/n 1266 1270 6869 Description Linkage, All Linkage Models Linkage, Wire Loop Models Spring-Assisted Linkage, All Linkage Models p/n 362 363 364 365 Description Door Seal Kit, for CL 4030, 5036 Door Seal Kit, for CL 6048 Door Seal Kit, for CL 7260 Door Seal Kit, for Pallet Burner
Draft Inducer
Ashtrol
Description Door Lock Kit, for steel-door CL 7260 and Pallet Burner Door Lock Kit, for other Cam Loc models (including CL 7260 cast-iron door)
Bolts to existing draft hood (fan included). Must use 5-amp fuse. Do not use CL 7260 HighOutput fan (p/n 5549) if a burner has been installed on the outdoor furnace. The 203 Blower & Motor, 1/15-hp can be used if a fan only is needed for the high output draft inducer. Draft Inducer (p/n 700) - 180 cfm; Draft Inducer (5549) - 450 cfm.
p/n 400 500 700 6576 5549 203 8563 Description Draft Inducer, Side Draft Draft Inducer, Ripple Front Door Draft Inducer, Flat Front Door Draft Inducer, CL 7260 Dual Fuel (w/fuses) Draft Inducer, CL 7260 High Output Blower & Motor, 1/15-hp Draft Inducer Fan (only)
Vent Cap
Replacement Vent Cap for Classic outdoor furnaces helps prevent water loss through the vent pipe.
p/n 320 Description Vent Cap
September 2012
17
Rocker Switch
Because damper control solenoids are not Replacement Rocker Switches for furnaces. interchangeable, check measurement and Description application dates carefully. Solenoid (p/n 167) is Replacement Digital Temperature Controller for p/n 6500 Rocker Switch, Power Supply (on-off) for pre-June 2000 models. Solenoid (p/n 4184) Classic model outdoor furnaces only (after s/n 6501 Rocker Switch, Light Switch (on-off-on) is for models after June 2000. 25151). Includes Temperature Sensing Wire (p/n p/n Description 727).
167 4184 Solenoid, 1-5/8" center-to-center bracket hole Solenoid, 1-3/8" center-to-center bracket hole p/n 4221 Description Digital Temperature Controller
Photoelectric Eye
Kits replace the HeatTrac Controller on furnaces. Replacement Photoelectric Eye for furnaces. Kit (p/n 10904) is for furnaces with a hinged Description electrical box controller door. Kit (p/n 10902) is p/n 11998 Photoelectric Eye High Limit Switch (p/n 192) opens on temperature for furnaces with removable side panel cover. rise. Snap Discs are Dual Fuel replacement p/n Description snap discs (p/n 4099 is the center disc, p/n 5712 10904 HeatTrac Controller Update Kit (Models with Lens & Light Bulb Hinged Controller Door) is for the left and right side discs). 10902 HeatTrac Controller Update Kit (Models with
p/n 192 4099 5712 Description High Limit Switch, 190F Snap Disc, 185-200F Snap Disc, 145-160F Removable Side Panel Cover)
Light Switch
p/n 727
Selector Switch
Contact Block
LED Temperature Display (on outdoor furnaces from s/n 13428 to s/n 25151) requires Transformer (p/n 1496) for converting 110-volt Replacement Time Delay Relay for Dual Fuel Replacement Contact Block for Dual Fuel AC current to 12-volt DC current. furnaces. model furnaces.
p/n 5775 Description Time Delay Relay p/n 6497 Description Contact Block p/n 1497 1496 Description LED Temperature Display Transformer
18
September 2012
Replacement latch spring clips for rear panels Replacement rebrick for E-Classic rebox. and Reaction Chamber panel. Converts E-Classic 2300 models from propane Dimensions: 9" x 4-1/2" x 1-1/4". p/n Description to natural gas.
4357 Latch Spring Clip p/n 10598 Description Natural Gas Conversion Kit p/n 8856 Description Firebrick
Firebrick
p/n 10473
Replacement rebrick for E-Classic 2300 rebox. Dimensions: 4-1/2" x 4-1/2" x 1-1/4". Converts E-Classic 1400 or 2400 models from propane to natural gas.
NOTE: NG Conversion Kit only needed for gas burner kits sold before Dec. 1, 2010. After that date, complete gas burner kits are available.
p/n 10588 Description Natural Gas Conversion Kit, E-Classic 1400/2400 p/n 8560 Description Firebrick
Grate Rod
p/n 6257
Replacement left center or right center ceramic refractory grate for E-Classic 1400.
p/n 7771 7769 Description Ceramic Refractory Grate - Left Center, E-Classic 1400 Ceramic Refractory Grate - Right Center, E-Classic 1400
130 cfm Replacement Blower Fan Assembly (p/n 7259) for all E-Classic models except E-Classic 2300 models prior to s/n E17807 (for those models, use p/n 8563).
p/n 7259 8563 Description Blower Fan Assembly Blower Fan Assembly for E-Classic 2300 model prior to s/n E17808
Converts E-Classic IR models with an optional Replacement secondary air charge tube for LP gas burner (see above) from propane to E-Classic models. natural gas.
p/n Description 2500001 Natural Gas Conversion Kit, E-Classic IR Models p/n 1200007 1200024 1200025 Description Secondary Air Charge Tube, E-Classic 1450 Secondary Air Charge Tube, E-Classic 2400 Secondary Air Charge Tube, E-Classic 3200
September 2012
19
door
refractory
for Pre-formed door seals for E-Classic model doors. Kits include Silicone Door Seal and Black Silicone Adhesive.
p/n Description 2500027 Door Seal Kit, Silicone, for E-Classic 2300, 2400 and 3200 6000007 Door Seal only for E-Classic 2300, 2400 and 3200 2500028 Door Seal Kit, Silicone, for E-Classic 1400 and 1450 6000006 Door Seal only for E-Classic 1400 and 1450
Replacement rear lower clean out door refractory for E-Classic 3200.
p/n 11075 Description Ceramic Refractory Grate Rear Lower Clean Out Door, E-Classic 3200
Adds an air pulse timer relay to E-Classic 2300 wood only models for setting the duration of the air pulse and the length of time between them. For E-Classic 2300 wood only models with a Replacement upper refractory for E-Classic Replacement ignitor burner gasket for E-Classic serial number prior to E17808. 2400. Two upper refactory (p/n 10137) are 2300 models. p/n Description required per furnace.
p/n 10137 Description Refractory - Upper, E-Classic 2400 p/n 8838 Description Ignitor Burner Gasket 10835 Pulse Timer Kit
Replacement rebox refractory for E-Classic Replacement thermocouple for E-Classic 3200. models that utilize a thermocouple in the p/n Description Reaction Chamber. 11174 Ceramic Refractory Grate - Firebox, E-Classic
3200 p/n 7260 Description Thermocouple, Reaction Chamber
Replacement water level oat switch for E-Classic and Maxim models.
p/n 11430 Description Water Level Float Switch
20
September 2012
Replacement turbulators for E-Classic 2300 Used to clean the ue passageways of E-Classic models. Note there are three different lengths. 2300 models. Flue Brush Kit (p/n 310) includes Regulates the gas pressure from an LP tank. For Description 311, 312 and handle. Not to be used for cleaning p/n 8866 Turbulator, Short all E-Classic or Maxim models. 6" or 8" chimney. 8867 Turbulator, Medium
p/n 310 Description Flue Brush Kit 8868 Turbulator, Long p/n 1930 Description 2-Stage Gas Regulator Kit
Installs on the sides of E-Classic 2300 rebox to prevent obstruction of primary combustion outlets.
NOTE: Installation of this kit involves welding inside the rebox and must be installed only by a qualied service technician.
p/n 10844 Description Spacer Bar Kit
Cleaning Rod
Fusion Combustor Kit for E-Classic 2300 models with a serial number of 15106 or earlier (Kit p/n 10700) or with a serial number of 15107 or higher (Kit p/n 10702). Kits include rectangular refractory, curved refractory, late-style Fusion Combustor, rope gaskets and rebrick.
p/n 10700 10702 10639 Description Fusion Combustor Kit Fusion Combustor Kit Curved Refractory Only
Used to connect FireStar II controller on outdoor furnace to FireStar XP wi- module. Available in 100-ft and 1,000-ft rolls.
p/n Description 8200012 3-Conductor Shielded Cable, 100-ft roll 10489-SP 3-Conductor Shielded Cable, 1000-ft roll
Ash Shovel
Clear tubing for the E-Classic air proving switch. Part number is per foot. 10 feet required for E-Classic models.
p/n 3045 Description Air Proving Switch Tubing
Vent Cap
Replacement Vent Cap for E-Classic outdoor furnaces helps prevent water loss through the vent pipe.
p/n 320 Description Vent Cap
September 2012
21
Chimney Components
A C D E F
Used with electrical conduit reinforce chimney when ve 8" Stainless steel chimney currently shipped are used. Must be located with E-Classic models (except E-CL 1450). Chimney Band Clamp (p/n Shipped with E-CL 1400 since s/n E100299 and stress on the joint. E-CL 2300 since s/n E17856. Compatible with p/n Description Chimney Attachment Ring Chimney Extension (p/n 6500002). If connecting 774 to Chimney Extension (p/n 6500002), use 8" Chimney Band Clamp Kit (p/n 4518) at the joints, 6" Chimney Guy-Wire Band not Chimney Locking Band (p/n 10509). For outdoor applications only. Not to be used for venting of indoor heating appliances.
p/n 10508 10509 10774 Description Chimney Extension, 4' Chimney Locking Band Chimney Rain Cap, 8"
Chimney Adapter Kit (p/n 10895) converts CL 7260 and Pallet Burner models to the new (not included) to chimney style (p/n 6500002). The conversion or more sections will require three Chimney Extensions (p/n directly below 6" 6500002). 9535) to reduce Chimney Extension Components
p/n 10895 6172 6173 Description Chimney Adapter Kit, 10" to 8", for Pallet Burner and CL 7260 models Elbow, 8", 45-degree Chimney Section, 8" x 24" for Tower Installation
Attached to the outer casing of a 6" chimney to hold three guy-wires (not included). Recommended for chimneys exceeding the roof by 5' to 13' maximum.
p/n 776 Description Guy-Wire Band
Type HT listed, factory-built, all stainless steel chimney tee. Kits include chimney tee cover and chimney tee rope rings, unless otherwise noted. NOTE: Silicone (p/n 806) is not included.
p/n 10998 11605 6500000 Description Chimney Tee Kit - CL4030, 5036 and 6048 Chimney Tee Kit - CL 7260 and Pallet Burner Chimney Tee* - E-Classic 1400 (s/n E100300 and later), E-Classic 2300 (s/n E17857 and later) and E-Classic 2400 6500001 Chimney Tee* - E-Classic 3200 *Does NOT include chimney tee rope rings. Must be purchased separately.
Type HT listed, factory-built, all stainless steel 6" Installed in chimney tee to lower the burn rate. chimney section. Sections are four feet long. For use only with CL 4030, CL 5036 and CL 6048 models. p/n Description
6500004 Chimney Extension, 4' 4082 Chimney Rain Cap p/n 10970 Description Chimney Tee Restrictor Kit
22
September 2012
Rope Ring
Used to provide additional stability to chimneys Reinforces strength between two sections of 8" in installations where property damage could chimney. occur within the fall zone of the chimney. Guy wire is not included in kit. p/n Description
4518 Chimney Band Clamp Kit, 8" p/n 778 Description Chimney Guy-Wire Band Kit
Description Rope Ring, 1.5", 8" ID Rope Ring, 3/4", 8" ID Rope, 7/8", per foot Rope, 1", per foot
Reinforces strength of chimney support when several chimney sections are used. For use only with CL 4030, CL 5036 and CL 6048 models.
p/n 4554 Description Chimney Support Brace Kit
Used with electrical conduit Stainless steel Spark Arrestor for the new-style reinforce chimney when ve are used. Must be located chimney (p/n 6500002). Chimney Band Clamp (p/n p/n Description stress on the joint. 396 Spark Arrestor
p/n 774 Description Chimney Attachment Ring
September 2012
23
Insulation
Replacement Vent Cap helps prevent water loss through the vent pipe and indicates water level. For M175 models only.
p/n 319 Description Vent Cap - M175
Vent Cap
Transfer augers for external hoppers. Use 5-1/2' Auxiliary Auger Kit (p/n 2500007) with the 48-Bushel Hopper Kit (p/n 9660 or 9760) when the hopper is located to the side of the furnace. The 6' Auxiliary Auger Kit (p/n 2500008) and 8' Auxiliary Auger Kit (p/n 2500009) will not work with the 48-Bushel Hopper.
NOTE: For furnaces with a serial number prior to M16073, the Power Cord (p/n 4177) must be purchased separately.
p/n 2500008 2500007 2500009 4177 Description Auxiliary Auger Kit, 6' Auxiliary Auger Kit, 5-1/2' Auxiliary Auger Kit, 8' Power Cord (see note above)
Replacement Vent Cap helps prevent water loss Increases hopper capacity by 3 bushels. For through the vent pipe and indicates water level. M175 models only. For M250 models only. p/n Description
p/n 9220 Description Vent Cap - M250 4536 4537 Hopper Extension Kit - Green Hopper Extension Kit - Terra Brown
Snap Disc
Vibrator attaches to the side of the Maxim's integrated hopper to keep fuel from bridging. Templates provided for both M175 or M250 models.
p/n 9691 Description Hopper Vibrator Kit
Equips M175 or M250 with a battery back up. Provides power to clean out the burner auger in the event of a back burn condition during a power failure. Kit includes UPS, wiring, relay and brackets for M175 and M250.
p/n Description 2500005 Battery Clean Out Kit
Vibrator is installed on the auxiliary auger connected to an external 43-bushel or 48-bushel hopper. For use with Auxiliary Auger Kits 2500007, 2500008 and 2500009 only. Vibration occurs based on timer setting. Increases fuel storage capacity for Maxim M175 and M250 models. Does not include auxiliary auger. Use the 5-1/2' Auxiliary Auger Kit (p/n 2500007) to locate the 48-Bushel Hopper to the side of the outdoor furnace. Available in either green and olive gray or terra brown and taupe to match the Maxim. Dimensions: 48" x 48" x 66".
p/n 9760 9660 Description 48-Bushel Hopper Kit - Green and Olive Gray 48-Bushel Hopper Kit - Terra Brown and Taupe p/n 9458 Description Auxiliary Auger Vibrator w/Timer Kit
Door Seal Rope/Chimney Transition Box Cover Seal Rope for Maxim
Rope may be used for door seal or chimney transition box cover seal (each requires a 5-ft section). Sold by the foot. Silicone is not included.
p/n 809 Description Door Seal Rope, 3/4", priced per ft
Bag Holder attaches to the inside of the door of the 48-Bushel Hopper to support bag of fuel.
p/n 9804 Description Bag Holder Kit
24
September 2012
The aerator supplies oxygen to the fuel for the most complete combustion.
p/n 9710 Description Aerator, Stainless Steel
p/n 9504
Description Relay
p/n 6257
Includes rubber boot, spark plug wire terminal, spark plug wire and resistor cap.
p/n 9364 9542 Description Ignitor Wire Assembly - M175 Ignitor Wire Assembly - M250
4-Quart galvanized Ash Scoop is ideal for cleaning ashes from furnace.
p/n 315 Description Ash Scoop
Ignitor - M250
p/n 9896
24V Transformer
LO AD R C NE C
CL AS CL S 2 NO AS S3 TW WETET
p/n 4045
p/n 9268
p/n 9423
Used to monitor propane in a BBQ-style tank with Type 1 Acme threads connected to a Maxim furnace.
p/n 4220 Description Propane Shut-off with Level Indicator
p/n 10473
For use with M175 models only. Not recommended for use in cold weather.
p/n 5567 Description Gas Hose w/Regulator
September 2012
25
Replacement sensor for M175 models. Regulates the gas pressure from an LP tank. For all E-Classic or Maxim models.
p/n 1930 Description 2-Stage Gas Regulator Kit p/n 4288 Description Firebox Temp Sensor, M175
Replacements for M250 inspection window. 2" x 2" window for M250 models with s/n M2000002 to M2000063. 2" x 3" window for models with s/n M2000064 and higher.
p/n 9254 9527 9528 Description Inspection Window, 2" x 2" Inspection Window, 2" x 3" Inspection Window Gasket
Door Latch
p/n 4286 Description Burn Chamber w/Gasket, M175 models
Used to clean the ue passageways of M175 models. Flue Brush Kit (p/n 310) includes 311, 312 and handle. Not to be used for cleaning 6" or 8" chimney.
p/n 310 Description Flue Brush Kit
p/n 6179
Burner Auger
Used to clean the ue passageways of M250 models. Flue Brush Kit (p/n 390) includes 398, 312 and handle. Not to be used for cleaning 6" or 8" chimney.
p/n 390 Description Flue Brush Kit
Turbulator - M175
AutoRanging DMM
MODE Hz %
mA A
OFF
V Hz
CAP
AU
FF TO P O W ER O
p/n 9145
Replacement water level oat switch for Digital multimeter performs several electrical measurement functions in one simple-to-use E-Classic and Maxim models. instrument. p/n Description
11430 Water Level Float Switch p/n 2657 Description Digital Pocket Multimeter
26
September 2012
A C D E F
Type HT listed, factory-built, all stainless steel 6" chimney section. Sections are four feet long.
p/n 6797 4082 Description Chimney Extension, 4' Chimney Rain Cap
For use on an interior or exterior wall, stabilizes chimney while providing required clearance from combustible surface. Use of Chimney Attachment Rings at maximum intervals of 8' is recommended.
p/n 774 Description Chimney Attachment Ring
Guy-Wire Band
Three lengths of insulated chimney to obtain the required installation height. Features a 1/8-turn Twist-Lock assembly.
p/n 757 758 759 Description Chimney Length, 12" Chimney Length, 24" Chimney Length, 36"
Attached to the outer casing of the chimney to hold three guy-wires (not included). Recommended for chimneys exceeding the roof by 5' to 13' maximum.
p/n 776 Description Guy-Wire Band
September 2012
27
28
September 2012
September 2012
29
DEFINITIONS
American Society for Testing and Materials. Publishes standard specications for terminology, labeling, testing and production. The British thermal unit is a unit of measure equal to the amount of heat necessary to raise the temperature of one pound of water one degree Fahrenheit. A process of heat transfer whereby heat moves through a material or between two materials that are in direct contact with each other. The transfer of heat by movement of a liquid or a gas. Natural Convection is a result of movement caused by changes in density as temperature changes within a uid medium such as a liquid or a gas. Forced Convection is the result of mechanical force moving a uid or gas. An insert tting for Central PEX tubing. A crimp requires a crimp ring or clamp of comparable quality. A chemical process that changes the molecular structure of a plastic material by linking otherwise independent hydrocarbon chains. Cross-Linking creates a three-dimensional network of hydrocarbons. The difference in temperature between two opposing masses used to describe the potential that exists for heat transfer. Female iron pipe thread.
ASTM
The amount of energy (in Btu/hr) required for space heating. The transfer of heat from a contained space to the atmosphere surrounding it. Heat loss is the result of thermal conductivity through walls, windows, roofs and other building envelope components, as well as inltration losses due to the exchange of inside air with outside air. The loss of heat energy due to inltration which is expressed in Btu/hr. Inltration losses are calculated from the air changes per hour, differential indoor/ outdoor temperature and the heat carrying capability of the lost air. The average temperature of all the surfaces in a room. Male American National Taper Pipe Thread. American National Taper Pipe Thread is a standard thread used in the US. Abbreviation for polyethylene. Describes the rst four feet around the exposed perimeter of the slab. Abbreviated for cross-linked polyethylene. The loss of uid pressure between any two points in a ow-conducting system, expressed in pounds per square inch (psi). The loss of pressure is caused by friction against the tubing walls and is further inuenced by the tubing size, length and texture of the inside wall of the tube, ttings, valves and other components. Pressure loss is also inuenced by the temperature and viscosity of the uid. A measure of a materials ability to resist the ow of heat. R-Value is expressed in Btu/hr/ft2 and calculated by the formula 1/U=R.
/LH[ N3VHK PU
/LH[ 3VZZ
The process in which energy in the form of rays of light or heat is transferred from body to body without heating the intermediate air acting as the transfer medium. Soldered copper pipe tting.
Radiation
Conduction
Inltration Losses
The amount of Btuhr required to overcome the envelope losses of the room. The amount of insulation (expressed in R-Value) under the interior area of the slab. A property of materials that indicates the amount of heat (in Btu) that penetrates one square foot of a uniform material one inch thick in one hour for each degree Fahrenheit difference in temperature between the surfaces. It is expressed in Btu/(hr/ft2/F). The thermal conductivity of PEX is 0.22 Btu/(hr/ft2/F). Any material used to store heat energy or the afnity for heat energy. The capability of a material to transfer heat. Used to describe the conductance of a material or composite of materials in construction. U-Value is expressed in Btu/hr/ft2 and is the inverse function of R-Value. The speed of uid at a specic ow, expressed in feet per second (fps or ft/sec). An area of a radiant panel served by one or more loops, and individually controlled (either manually or automatically).
Under-Slab Insulation
Convection
Crimp
Thermal Mass
Cross-Linking
7,
U-Value
7LYPTL[LY(YLH
7,?
Velocity
- 07 - 7;
7YLZZ\YL3VZZ
Zone
Female American National Taper Pipe Thread. Abbreviation for high-density polyethylene. The pressure available at the outlet side of a pump, or inlet side of a ow-conducting system. It is expressed in feet of head, which is the height of a column of water that can be supported by a pump against standard atmospheric pressure.
/+7,
/LHK7 YLZZ\YL
R-Value
30
September 2012