You are on page 1of 48

Convertible Floor/Ceiling/

Cooling only or
Reversible split-system
R22
MWX 512-518-524-536 GB+ TTK 512518-524-530-536 PB/RB/NB/ND
MWX 512-518-524-536 GB+ TWK 512518-524-530-536 PB/RB/NB/ND
R407C
MWX 512-518-524-536 GB+ TTK 512518-524-530-536 CB/CD

MS-PRC010-GB

American Standard Inc. 2001

Contents

MS-PRC010-GB

Contents

Features and Benefits

Model Number Description

Application Considerations

General Data

Performance Data

11

Electrical Data

14

Dimensional Data

15

Typical Wiring Diagrams

28

Interconnecting Diagram

42

Features and Benefits

Convertible console/
ceiling mounted indoor
unit MWX

Outdoor units TTK/ TWK

Main components of the MWX


3-speed centrifugal fan motor
assembly.
Heat exchanger with aluminium
fins and copper tube.
Washable air filters.
Multi- directional air louvres.
2 versions : with or without
electric heater.
Colour : RAL 9002.

Main components of outdoor units


TTK/ TWK single-circuit
Axial fan motor assembly.
Rotary hermetic (sizes 512 to 524),
reciprocating (sizes 530 to 536
NB/ND) or scroll (sizes 530 to 536
CB/CD) compressor.
Refrigerant charge R22 or R407C.
Integral condensate tray
(sizes 512 to 536).
Aluminium finned coil with copper
tubes.
Fan protection grille and
condenser coil.
Colour : RAL 9002.

MS-PRC010-GB

Model Number Description

Indoor unit

MWX

12

B
Electric characteristics :
B = 230 V/1 Ph/50 Hz
Refrigerant compatibility
G = R22 and R407C
Nominal capacity in Mbh
12 = 12 Mbh
Connections
5 = Flare
Configuration
MWX = Convertible - Reversible

Outdoor unit

TTK

12

B
Electric characteristics :
B = 230 V/1 Ph/50 Hz
Refrigerant :
P, R, N = R22
C = R407C
Nominal capacity in Mbh
12 = 12 Mbh
Connections
5 = Flare
Configuration
TTK = Outdoor unit - Cooling only
TWK = Outdoor unit - Reversible

MS-PRC010-GB

Application Considerations

Application of this product should be within the catalogued airflow and performance consideration.

Clearance requirements
The recommended clearances identified with unit dimensions should be maintained to assure adequate serviceability,
maximum capacity and peak operating efficiency. Actual clearances that appear inadequate should be reviewed with
the local TRANE representative.

Operating limits.
Table 1.1 R22 Refrigerant
Cooling mode
+10C standard
-7C with low ambient kit
+43C

Min. outdoor air temperature


Max. outdoor air temperature

Heating mode
-7C (TWK 512 to 524 PB/RB)
-12C (TWK 530-536 NB/ND)
+20C

R407C
Cooling mode
+10C standard
-7C with low ambient kit
+43C

Min. outdoor air temperature


Max. outdoor air temperature

Recommended interconnecting lines - condensing units

Compressor
unit

Blower
unit

Table 2

Outdoor unit
TTK 512 PB
TTK 518 RB
TTK 524 RB
TTK 530 NB/ND
TTK 536 NB/ND
TWK 512 PB
TWK 518 RB
TWK 524 RB
TWK 530 NB/ND
TWK 536 NB/ND
TTK 512 CB
TTK 518 CB
TTK 524 CB
TTK 530 CB/CD
TTK 536 CB/CD

Max. length
(m)
L3

Max.level difference
(m)

Line diameters
(inches)

D2

D1

Gas

Liquid

20
24
24
12
40
18
40
20
24
24
12
40
18
40
19
20
30
17
31
27

12
18
18
12
18
18
18
12
18
18
12
18
18
18
11
18
18
15
16
14

15
24
24
12
24
18
24
12
24
24
12
24
18
24
17
18
28
15
29
25

1/2
5/8
5/8
5/8
7/8
3/4
7/8
1/2
5/8
5/8
5/8
7/8
3/4
7/8
1/2
5/8
5/8
5/8
7/8
3/4

1/4
3/8
3/8
3/8
3/8
1/4
3/8
3/8
3/8
3/8
1/4
3/8
3/8
3/8
3/8

MS-PRC010-GB

General Data

Table 3.1 : R22 Refrigerant


Indoor unit

MWX
512 GB
TTK
512
PB

Outdoor unit

Electrical power supply


Indoor unit
Outdoor unit
Capacity
Cooling capacity(1)
Power input (Cooling mode)
Heating capacity (2)
Power input (Heating mode)
Coefficient of performance
Current
Indoor unit Current amps
Indoor unit Current amps (3)
Outdoor unit Current amps
Indoor unit Start- up amps
Outdoor unit Start- up amps
Compressor
Number -Type
Fan
Indoor unit
Outdoor unit
Air flow
Indoor unit Low speed
Indoor unit Medium speed
Indoor unit High speed
Outdoor unit
Filter
Air filter
Expansion
Cooling mode
Heating mode
Refrigerant connections
Indoor unit Flare gas - liquid
Outdoor unit Flare gas- liquid

MS-PRC010-GB

(V/ Ph/ Hz)


(V/ Ph/ Hz)

Split system, Cooling only


MWX
MWX
MWX
518 GB
524 GB
536 GB
TTK
TTK
TTK
518
524
530
RB
RB
NB/ND

MWX
536 GB
TTK
536
NB/ND

MWX
512 GB
TWK
512
PB

Split system, reversible


MWX
MWX
MWX
518 GB
524 GB
536 GB
TWK
TWK
TWK
518
524
530
RB
RB
NB/ND

MWX
536 GB
TWK
536
NB/ND

230/1/50
230/1/50

230/1/50400/3+N/50

230/1/50

230/1/50400/3+N/50

(kW)
(kW)
(kW)
(kW)

3.5
1.4
-

5.2
2.2
-

6.9
2.9
-

9.3
3.6
-

10.8
4.3
-

3.5
1.4
3.7
1.2
3.1

5.2
2.2
6.0
2.0
3.0

6.9
2.9
7.4
2.3
3.2

9.3
3.6
9.7
2.9
3.3

10.8
4.3
11.2
3.5
3.2

(A)
(A)
(A)
(A)
(A)

0.47
9.2
6.5
0.59
32

0.52
13.5
10
0.75
51

0.7
18.1
11.8
0.96
56

0.7
26.8
20.2/27.8
1.12
89/43

0.7
26.8
23/9.3
1.12
98/44

0.47
9.2
6.5
0.59
32

0.52
13.5
10
0.75
51

0.7
18.1
11.8
0.96
56

0.7
26.8
20.2/7.8
1.12
89/43

0.7
26.8
23/9.3
1.12
98/44

1- Rotary

1-Reciprocating

Type
Type
(m 3 /h)
(m 3 /h)
(m 3 /h)
(m 3 /h)

1- Rotary

1-Reciprocating

Centrifugal
Axial
510
585
680
1050

555
680
810
2200

765
960
1150
2200

1275
1420
1550
3230

1275
1420
1550
3230

510
585
680
1050

555
680
810
2200

765
960
1150
2200

1275
1420
1550
3230

1275
1420
1550
3230

Nber -Type

3- Polypropylene

4- Polypropylene

3- Polypropylene

4- Polypropylene

Type/ Unit
Type/ Unit

Capillary/outdoor
-

Accutron/indoor
-

Capillary/outdoor
Accutron/outdoor

Accutron/indoor
Accutron/indoor

(inch)
(inch)

1/2-1/4
1/2-1/4

5/8-3/8
5/8-3/8

3/4-3/8
3/4-3/8

1/2-1/4
1/2-1/4

5/8-3/8
5/8-3/8

3/4-3/8
3/4-3/8

Table 3.2: R22 Refrigerant


Indoor unit

MWX
512 GB
TTK
512
PB

Outdoor unit

Refrigerant charge
Outdoor unit
Sound power level
Indoor unit L/ M/ H
Outdoor unit
Dimensions
Indoor unit
Length
Depth
Height
Outdoor unit
Length
Depth
Height
Dimensions (packed)
Indoor unit
Length
Depth
Height
Outdoor unit
Length
Depth
Height
Weight
Indoor unit
Indoor unit with electric heater
Outdoor unit
Weight (packed)
Indoor unit
Indoor unit with electric heater
Outdoor unit
Colour
Indoor unit
Outdoor unit
Recommended fuse size (system)
Current amps
Current amps (3)

Split system, Cooling only


MWX
MWX
MWX
518 GB
524 GB
536 GB
TTK
TTK
TTK
518
524
530
RB
RB
NB/ND

MWX
536 GB
TTK
536
NB/ND

MWX
512 GB
TWK
512
PB

Split system, reversible


MWX
MWX
MWX
518 GB
524 GB
536 GB
TWK
TWK
TWK
518
524
530
RB
RB
NB/ND

MWX
536 GB
TWK
536
NB/ND

(kg)

0.9

1.6

1.8

2.7

2.7

0.9

1.8

2.0

2.7

2.7

(dB( A))
(dB( A))

34/37/41
64

36/40/45
70

36/40/46
68

43/46/48
73

43/46/48
74

34/37/41
64

36/40/45
70

36/40/46
68

43/46/48
73

43/46/48
74

(mm)
(mm)
(mm)
(mm)
(mm)
(mm)

1085
248

1335

1585

1085
248

268

1335

622
700
253
530

(mm)
(mm)
(mm)

622

1018
360
595

1148
290

1018
360
798

1398

700
253
530

1648

1018
360
595

1148
290

305

810
315
590

(kg)
(kg)
(kg)

36
37
36

39
40
60

48
50
67

(kg)
(kg)
(kg)

38
39
39

41
42
68

51
53
75

1018
360
798

1398

1648
305

655

(mm)
(mm)
(mm)

1585
268

655

1180
445
725

1180
445
930

810
315
590

70
72
89

36
37
38

39
40
63

48
50
70

96

38
38
41

41
42
71

51
53
78

16
20

16
32

16
32

87
74
76
94

1180
445
725

1180
445
930
70
72
91

93
74
76

98

100

RAL9002
RAL9002
(A)
(A)

16
20

16
32

16
32

32/16
50/40

32/16
50/40

(1) In the following conditions: Outside temperature: 35C ; 27C DB, 19C WB; Return air temperature: 27C DB/19 C WB.
(2) In the following conditions: Outside temperature: 7C DB/ 6C DB; Return air temperature: 20C DB.
(3) With electric heater
(4) Sound pressure levels: measurements taken in a furnished office with a reverberation time of 0.5 seconds

MS-PRC010-GB

Table 4.1 : R407C Refrigerant


Indoor unit

MWX
512 GB
TTK
512 CB

Outdoor unit
Electrical power supply
Indoor unit
Outdoor unit
Capacity
Cooling capacity(1)
Power input (Cooling mode)
Current
Indoor unit Current amps
Indoor unit Current amps (3)
Outdoor unit Current amps
Indoor unit Start- up amps
Outdoor unit Start- up amps
Compressor
Number -Type
Fan
Indoor unit
Outdoor unit
Air flow
Indoor unit Low speed
Indoor unit Medium speed
Indoor unit High speed
Outdoor unit
Filter
Air filter
Expansion
Cooling mode
Refrigerant connections
Indoor unit Flare gas - liquid
Outdoor unit Flare gas- liquid

MS-PRC010-GB

(V/ Ph/ Hz)


(V/ Ph/ Hz)

MWX
518 GB
TTK
518 CB

Split system, Cooling only


MWX
524 GB
TTK
524 CB

MWX
536 GB
TTK
530 CB/CD

MWX
536 GB
TTK
536 CB/CD

230/1/50
230/1/50

230/1/50-400/3 +N/50

(kW)
(kW)

3.4
1.31

5.3
1.84

6.9
2.65

9.4 / 9.1
3.4 / 3.1

11.1 / 10.9
4.2 / 3.8

(A)
(A)
(A)
(A)
(A)

0.47
9.2
5.58
0.59
28.7

0.52
13.5
8.34
0.75
44.0

0.7
18.1
11.24
0.96
72.0

0.7
26.8
19.81 / 7.72
1.12
97.04 / 45.54

0.7
26.8
24.61 / 11.12
1.12
116.04 / 52.04

1 - Rotary
Type
Type
(m 3 /h)
(m 3 /h)
(m 3 /h)
(m 3 /h)

1 - Scroll
Centrifugal
Axial

510
585
680
1050

555
680
810
2200

765
960
1150
2200

1275
1420
1550
3230

1275
1420
1550
3230

Nber -Type

3- Polypropylene

4- Polypropylene

Type/ Unit

Capillary/outdoor

Accutron/indoor

(inch)
(inch)

1/2-1/4
1/2-1/4

5/8-3/8
5/8-3/8

3/4-3/8
3/4-3/8

Table 4.2 : R407C Refrigerant


MWX
512 GB
TTK
512 CB

MWX
518 GB
TTK
518 CB

Split system, Cooling only


MWX
524 GB
TTK
524 CB

MWX
536 GB
TTK
530 CB/CD

MWX
536 GB
TTK
536 CB/CD

(kg)

0.9

1.6

1.8

2.5

2.5

(dB( A))
(dB( A))

34/37/41
64

36/40/45
70

36/40/46
68

43/46/48
73

43/46/48
74

(mm)
(mm)
(mm)

1085
248

(mm)
(mm)
(mm)

700
253
530

1018
360
595

(mm)
(mm)
(mm)

1148
290

1398

(mm)
(mm)
(mm)

810
315
590

(kg)
(kg)
(kg)

36
37
36

39
40
60

48
50
67

(kg)
(kg)
(kg)

38
39
39

41
42
68

51
53
75

Indoor unit
Outdoor unit
Refrigerant charge
Outdoor unit
Sound power level
Indoor unit L/ M/ H
Outdoor unit
Dimensions
Indoor unit
Length
Depth
Height
Outdoor unit
Length
Depth
Height
Dimensions (packed)
Indoor unit
Length
Depth
Height
Outdoor unit
Length
Depth
Height
Weight
Indoor unit
Indoor unit with electric heater
Outdoor unit
Weight (packed)
Indoor unit
Indoor unit with electric heater
Outdoor unit
Colour
Indoor unit
Outdoor unit
Recommended fuse size type (system)
Indoor unit
Current amps
Current amps (3)
Outdoor unit
Current amps

1335

1585
268
622
1018
360
798

1648
305
655

1180
445
725

1180
445
930
70
72
87

89
74
76

94

96

2
16
25 / 10
32

2
16
32 / 16
32

RAL9002
RAL9002

(A)
(A)

10
20

2
10

2
16

(A)

16

25

(1) In the following conditions : Outside temperature : 35C ; 27C DB, 19 C WB ; Return air temperature : 27C DB/ 19C WB.
(2) In the following conditions : Outside temperature : 7C DB/ 6C DB ; Return air temperature : 20C DB.
(3) With electric heater
(4) Sound pressure levels : measurements taken in a furnished office with a reverberation time of 0.5 seconds

10

MS-PRC010-GB

Performance Data

Cooling capacities
Table 5 : Cooling only system - R22 Refrigerant
Indoor unit
Inside temperature
Outdoor unit
(C) DB/WB

MWX 512 GB
+
TTK 512 PB
MWX 518 GB
+
TTK 518 RB
MWX 524 GB
+
TTK 524 RB
MWX 536 GB
+
TTK 530 NB/ND
MWX 536 GB
+
TTK 536 NB/ND

21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21

25
TCC
(kW)
3.4
3.6
3.9
4.1
5.0
5.4
5.7
6.1
6.7
7.1
7.5
7.9
9.5
10.2
10.9
11.7
10.5
11.3
12.1
12.9

Table 6 : Cooling only system - R407c Refrigerant


Indoor unit
Inside temperature
Outdoor unit
(C) DB/WB

MWX 512 GB
+
TTK 512 CB
MWX 518 GB
+
TTK 518 CB
MWX 524 GB
+
TTK 524 CB
MWX 536 GB
+
TTK 530 CB
MWX 536 GB
+
TTK 530 CD
MWX 536 GB
+
TTK 536 CB
MWX 536 GB
+
TTK 536 CD

MS-PRC010-GB

21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21

30
SHR
0.77
0.83
0.77
0.72
0.73
0.78
0.73
0.68
0.75
0.80
0.75
0.70
0.75
0.80
0.74
0.69
0.72
0.77
0.71
0.66

TCC
(kW)
3.3
3.5
3.7
4.0
4.8
5.2
5.5
5.8
6.4
6.8
7.1
7.6
8.9
9.6
10.3
11.0
10.0
10.7
11.5
12.2

25
TCC
(kW)
3.3
3.6
3.8
4.0
5.1
5.4
5.8
6.2
6.7
7.1
7.6
8.1
9.1
9.8
10.4
11.1
8.6
9.3
9.9
10.5
10.8
11.5
12.2
13.0
10.5
11.3
12.0
12.8

SHR
0.78
0.84
0.78
0.73
0.75
0.80
0.74
0.69
0.76
0.82
0.77
0.71
0.76
0.82
0.76
0.71
0.74
0.78
0.73
0.67

30
SHR
0.76
0.82
0.76
0.71
0.73
0.78
0.72
0.67
0.75
0.80
0.74
0.69
0.76
0.81
0.76
0.70
0.77
0.83
0.77
0.72
0.72
0.76
0.71
0.66
0.72
0.77
0.71
0.66

TCC
(kW)
3.2
3.4
6.6
3.8
4.8
5.2
5.6
6.0
6.4
6.8
7.3
7.7
8.7
9.3
9.9
10.5
8.3
8.9
9.5
10.1
10.3
11.0
11.7
12.4
10.1
10.8
11.5
12.3

SHR
0.78
0.84
0.78
0.72
0.74
0.79
0.74
0.68
0.76
0.81
0.76
0.71
0.77
0.83
0.77
0.72
0.79
0.85
0.79
0.73
0.73
0.78
0.72
0.67
0.73
0.78
0.73
0.68

Outside temperature (C)


32
35
TCC
SHR
TCC
SHR
(kW)
(kW)
3.2
0.79
3.1
0.79
3.4
0.85
3.3
0.87
3.7
0.78
3.5
0.80
3.9
0.73
3.8
0.74
4.7
0.75
4.7
0.75
5.1
0.80
5.0
0.81
5.4
0.74
5.2
0.75
5.7
0.70
5.6
0.71
6.3
0.76
6.1
0.77
6.7
0.82
6.5
0.83
7.0
0.77
6.9
0.77
7.4
0.72
7.3
0.73
8.7
0.77
8.4
0.78
9.4
0.83
9.0
0.84
10.0
0.77
9.7
0.78
10.8
0.71
10.4
0.72
9.7
0.74
9.4
0.75
10.5
0.79
10.1
0.80
11.2
0.74
10.8
0.75
12.0
0.68
11.5
0.69

TCC
(kW)
3.0
3.2
3.4
3.6
4.5
4.8
5.1
5.4
5.9
6.3
6.7
7.0
7.8
8.4
9.1
9.7
8.8
9.4
10.1
10.8

Outside temperature (C)


32
35
TCC
SHR
TCC
SHR
(kW)
(kW)
3.1
0.78
3.0
0.79
3.3
0.85
3.2
0.86
3.5
0.79
3.4
0.80
3.8
0.73
3.7
0.74
4.7
0.75
4.6
0.76
5.1
0.80
5.0
0.81
5.5
0.74
5.3
0.75
5.8
0.69
5.7
0.70
6.2
0.77
6.1
0.77
6.7
0.82
6.5
0.83
7.1
0.77
6.9
0.78
7.5
0.71
7.3
0.72
8.5
0.78
8.2
0.79
9.1
0.84
8.8
0.85
9.6
0.78
9.4
0.79
10.3
0.73
10.0
0.74
8.1
0.79
7.9
0.80
8.7
0.86
8.5
0.87
9.3
0.80
9.1
0.81
9.9
0.74
9.7
0.75
10.0
0.73
9.8
0.74
10.7
0.78
10.4
0.79
11.4
0.73
11.1
0.74
12.1
0.68
11.8
0.69
9.8
0.74
9.6
0.74
10.5
0.79
10.3
0.80
11.2
0.73
10.9
0.74
12.0
0.68
11.7
0.69

TCC
(kW)
2.9
3.1
3.3
3.5
4.4
4.7
5.1
5.5
5.7
6.1
6.5
6.9
7.7
8.2
8.8
9.4
7.5
8.1
8.6
9.2
9.2
9.8
10.4
11.1
9.1
9.7
10.3
11.0

40

43
SHR
0.81
0.88
0.82
0.76
0.76
0.82
0.76
0.72
0.78
0.85
0.79
0.74
0.80
0.87
0.80
0.75
0.77
0.83
0.77
0.71

TCC
(kW)
2.8
3.0
3.3
3.5
4.4
4.7
5.0
5.2
5.8
6.2
6.5
6.9
7.5
8.1
8.7
9.3
8.4
9.1
9.7
10.4

40

SHR
0.82
0.89
0.84
0.78
0.77
0.83
0.78
0.72
0.79
0.85
0.80
0.74
0.82
0.89
0.82
0.76
0.78
0.84
0.78
0.72

43
SHR
0.81
0.88
0.82
0.76
0.77
0.83
0.77
0.71
0.79
0.86
0.80
0.74
0.81
0.88
0.82
0.76
0.82
0.89
0.83
0.77
0.76
0.81
0.76
0.70
0.76
0.82
0.76
0.71

TCC
(kW)
2.8
3.0
3.2
3.4
4.3
4.6
5.0
5.3
5.6
6.0
6.3
6.7
7.4
7.9
8.5
9.1
7.3
7.9
8.4
8.9
8.8
9.5
10.1
10.7
8.8
9.3
10.0
10.6

SHR
0.82
0.89
0.83
0.77
0.78
0.84
0.78
0.72
0.80
0.87
0.81
0.76
0.82
0.90
0.83
0.77
0.83
0.90
0.84
0.78
0.77
0.82
0.77
0.71
0.77
0.83
0.77
0.72

11

Table 7 : Reversible system- R22 Refrigerant


Indoor unit
Inside temperature
Outdoor unit
(C) DB/WB

MWX 512 GB
+
TWK 512 PB
MWX 518 GB
+
TWK 518 RB
MWX 524 GB
+
TWK 524 RB
MWX 536 GB
+
TWK 530
NB/ND
MWX 536 GB
+
TWK 536
NB/ND

12

21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21
21/15
25/17
27/19
29/21

25
TCC
(kW)
3.4
3.6
3.9
4.1
5.0
5.4
5.7
6.1
6.7
7.1
7.5
7.9
9.5
10.2
10.9
11.7
10.5
11.3
12.1
12.9

30
SHR
0.77
0.83
0.77
0.72
0.73
0.78
0.73
0.68
0.75
0.80
0.75
0.70
0.75
0.80
0.74
0.69
0.72
0.77
0.71
0.66

TCC
(kW)
3.3
3.5
3.7
4.0
4.8
5.2
5.5
5.8
6.4
6.8
7.1
7.6
8.9
9.6
10.3
11.0
10.0
10.7
11.5
12.2

SHR
0.78
0.84
0.78
0.73
0.75
0.80
0.74
0.69
0.76
0.82
0.77
0.71
0.76
0.82
0.76
0.71
0.74
0.78
0.73
0.67

Outside temperature (C)


32
35
TCC
SHR
TCC
SHR
(kW)
(kW)
3.2
0.79
3.1
0.79
3.4
0.85
3.3
0.80
3.7
0.78
3.5
0.74
3.9
0.73
3.8
0.75
4.7
0.75
4.7
0.81
5.1
0.80
5.0
0.75
5.4
0.74
5.2
0.71
5.7
0.70
5.6
0.77
6.3
0.76
6.1
0.83
6.7
0.82
6.5
0.77
7.0
0.77
6.9
0.73
7.4
0.72
7.3
0.78
9.7
0.77
8.4
0.78
9.4
0.83
9.0
0.84
10.0
0.77
9.7
0.78
10.8
0.71
10.4
0.72
9.7
0.74
9.4
0.75
10.5
0.79
10.1
0.80
11.2
0.74
10.8
0.75
12.0
0.68
11.5
0.69

40
TCC
(kW)
3.0
3.2
3.4
3.6
4.5
4.8
5.1
5.4
5.9
6.3
6.7
7.0
7.8
8.4
9.1
9.7
8.8
9.4
10.1
10.8

43
SHR
0.81
0.88
0.82
0.76
0.76
0.82
0.76
0.72
0.78
0.85
0.79
0.74
0.80
0.87
0.80
0.75
0.77
0.83
0.77
0.71

TCC
(kW)
2.8
3.0
3.3
3.5
4.4
4.7
5.0
5.2
5.8
6.2
6.5
6.9
7.5
8.1
8.7
9.3
8.4
9.1
9.7
10.4

SHR
0.82
0.89
0.84
0.78
0.77
0.83
0.78
0.72
0.79
0.85
0.80
0.74
0.82
0.89
0.82
0.76
0.78
0.84
0.78
0.72

MS-PRC010-GB

Heating capacities
Table 8 : Reversible system - R22 Refrigerant
Indoor unit
Outdoor unit
Inside temperature
(C)
MWX 512 GB
+
TWK 512 PB
MWX 518 GB
+
TWK 518 RB
MWX 524 GB
+
TWK 524 RB
MWX 536 GB
+
TWK 530 NB/ND
MWX 536 GB
+
TWK 536 NB/ND

18
20
24
18
20
24
18
20
24
18
20
24
18
20
24

Table 9 : Electric heater heating capacities


Indoor unit
Heating capacity (kW)

-5/-5.5
HC
COP
(kW)
2.8
2.7
2.7
2.6
2.7
2.5
4.3
2.7
4.3
2.7
4.3
2.5
5.3
2.8
5.3
2.8
5.2
2.6
6.7
2.8
6.6
2.7
6.3
2.5
6.9
2.9
6.8
2.7
6.6
2.5

MWX 512 GB
2.0

-3/-4
HC
(kW)
2.8
2.8
2.8
4.6
4.5
4.5
5.5
5.5
5.5
7.1
7.0
6.7
7.5
7.4
7.2

Outside temperature (C) DB/WB


2/1
7/6
COP
HC
COP
HC
(kW)
(kW)
2.7
3.2
3.0
3.5
2.7
3.2
2.9
3.5
2.5
3.1
2.7
3.5
2.8
5.1
2.9
5.7
2.7
5.1
2.9
5.7
2.6
5.1
2.7
5.7
2.9
6.2
3.1
6.9
2.8
6.2
3.0
6.9
2.7
6.1
2.8
6.9
2.9
8.1
3.1
9.3
2.8
8.0
3.0
9.2
2.6
7.8
2.8
8.9
2.9
9.0
3.0
10.4
2.8
8.9
2.9
10.3
2.6
8.6
2.7
10.0

MWX 518 GB
3.0

MWX 524 GB
4.0

COP
3.2
3.1
2.9
3.1
3.0
2.8
3.3
3.2
3.0
3.3
3.2
3.0
3.1
3.0
2.9

12/10.5
HC
COP
(kW)
3.9
3.4
3.9
3.3
3.9
3.0
6.3
3.2
6.3
3.1
6.3
2.9
7.6
3.4
7.6
3.3
7.6
3.0
10.5
3.5
10.4
3.4
10.1
3.2
11.9
3.2
11.7
3.1
11.4
3.0

MWX 536 GB
6.0

Table 10 : Cooling and heating capacity correction factors

Cooling capacity
Heating capacity

MS-PRC010-GB

Low
x 0.92
x 0.94

Fan speed
Medium
x 0.95
x 0.97

High
x 1.0
x 1.0

13

Electrical data

For recommended Fuse Size,Wire Section and Maximum Wire Length, refer to
Table 3.1 to 4.2 Section Recommended fuse size (system).
Table 19 : Control interconnection
Outdoor Unit
TTK 512 PB/CB
TTK 518 RB/CB
TTK 524 RB/CB
TTK 530 NB/ND/CB/CD
TTK 536 NB/ND/CB/CD
TWK 512 PB
TWK 518 RB
TWK 524 RB
TWK 530 NB/ND
TWK 536 NB/ND

Nbr Wires x Section area (mm)


3 x 1.5
2 x 1.5
2 x 1.5
2 x 1.5
2 x 1.5
6 x 1.5
5 x 1.5
5 x 1.5
6 x 1.5
6 x 1.5

Table 20 : Outdoor unit Power Supply(1)


Outdoor Unit
TTK 512 PB/CB
TTK 518 RB/CB
TTK 524 RB/CB
TTK 530 NB/CB
TTK 530 ND/CD
TTK 536 NB/CB
TTK 536 ND/CD
TWK 512 PB
TWK 518 RB
TWK 524 RB
TWK 530 NB/ND
TWK 536 NB/ND

Nbr Wires x Section area (mm)


3 x 2.5
3 x 2.5
3 x 4
4x 2.5
3 x 4
4x 2.5
3 x 2.5
3 x 2.5
3 x 4/4x 2.5
3 x 4/4x 2.5

Table 21 : Indoor unit Power Supply (1)


Outdoor Unit
MWX 512 GB
MWX 518 GB
MWX 524 GB
MWX 536 GB

Without electric Heater


Nbr Wires x Section area (mm)
3 x 1.5
3 x 1.5
3 x 1.5
3 x 1.5

With Electric Heater


Nbr Wires x Section area (mm)
3 x 2.5
3 x 2.5
3 x 4
4 x 4

(1) Indoor and outdoor units are powered separately

14

MS-PRC010-GB

Dimensional data

MS-PRC010-GB

15

16

MS-PRC010-GB

MS-PRC010-GB

17

18

MS-PRC010-GB

MS-PRC010-GB

19

20

MS-PRC010-GB

MS-PRC010-GB

21

22

MS-PRC010-GB

MS-PRC010-GB

23

24

MS-PRC010-GB

MS-PRC010-GB

25

26

MS-PRC010-GB

MS-PRC010-GB

27

Typical Wiring diagram

28

MS-PRC010-GB

MS-PRC010-GB

29

30

MS-PRC010-GB

MS-PRC010-GB

31

32

MS-PRC010-GB

MS-PRC010-GB

33

34

MS-PRC010-GB

MS-PRC010-GB

35

36

MS-PRC010-GB

MS-PRC010-GB

37

38

MS-PRC010-GB

MS-PRC010-GB

39

40

MS-PRC010-GB

MS-PRC010-GB

41

Inderconnecting diagram

42

MS-PRC010-GB

MS-PRC010-GB

43

44

MS-PRC010-GB

MS-PRC010-GB

45

46

MS-PRC010-GB

MS-PRC010-GB

47

Literature Order Number

MS-PRC010-GB

Date

0201

New

The Trane Company


An American Standard Company
www.trane.com

Stocking Location

Europe

For more information contact


your local sales office or
e-mail us at comfort@trane.com

Socit Trane Socit Anonyme au capital de 41500 000 F Siege Social: 1 rue des Amriques
88190 Golbey France Siret 306 050 188-00011 RSC Epinal B 306 050 188
Numro didentification taxe intracommunanutaire: FR 83 3060501888

Since The Trane Company has a policy of continuous product improvement, it reserves the right to change
design and specifications without notice.

You might also like