3G3MX2

Designed With Machine Automation in Mind


Current vector control High starting torque: 200% at 0.5Hz Double rating VT 120%/1min and CT 150%/1min Speed range up to 1000 Hz IM & PM motor control Torque control in open loop vector Positioning functionality Built-in application functionality (i.e. Brake control) User programmable as standard Safety embedded compliant with ISO13849-1 (double input circuit and external device monitor EDM) USB port for PC programming 24 VDC backup supply for control board Fieldbus communications: Modbus, DeviceNet, Profibus, Componet, Ethercat, ML-II and CanOpen PC configuration tool: CX-Drive RoHS, CE, cULus

Ratings
200 V Class single-phase 0.2 to 2.2 kW (1/8 to 3.0 HP) 200 V Class three-phase 0.2 to 15.0 kW (1/8 to 20 HP) 400 V Class three-phase 0.4 to 15.0 kW (1/2 to 20 HP)

System configuration
Power Supply

MCCB USB Cable

CX-Drive CX-One

Input AC Reactor

Remote Operator Extansion Cable

LCD 5 lines Remote Operator

Filter Communication Option Board

3G3MX2

Braking Resistor

DC Reactor Choke

Motor

Output AC Reactor

Ground

Frequency inverters

Specifications
Type designation

3G3MX2 A B 0 0 2 - E
3G3MX2 series
A: Standard specs E: Europe standard Max. applicable motor output 002: 0.2 kW (0.25 HP) 150: 15.0 kW (20 HP)

Voltage: B: 2: 4: Single-phase 200 VAC Three-phase 200 VAC Three-phase 400 VAC

200 V class 3G3MX-A


Single-phase: MX2@
Motor kW2

AB001 A2001 0.2 0.1 0.4 0.2 0.4 0.3 1.2 1.0

AB002 A2002 0.4 0.2 0.6 0.5 0.7 0.6 1.9 1.6

AB004 A2004 0.55 0.4 1.2 1.0 1.4 1.2 3.5 3.0

AB0071 A2007 1.1 0.75 2.0 1.7 2.4 2.0 6.0 5.0

AB015 A2015 2.2 1.5 3.3 2.7 3.9

AB022 A2022 3.0 2.2 4.1 3.8 4.9

A2037 5.5 3.7 6.7 6.0 8.1

A2055 7.5 5.5 10.3 8.6 12.4

A2075 11 7.5 13.8 11.4 16.6 13.7 40.0 33.0

A2011 15 11 19.3 16.2 23.2 19.5 56.0 47.0

A2150 18.5 15 23.9 20.7 28.6 24.9 69.0 60.0

Three-phase: MX2@ For VT setting For CT setting 200 VT 200 CT 240 VT

Output characteristics

Inverter capacity kVA

Power supply

240 CT Rated output current (A) at VT Rated output current (A) at CT Max. output voltage Max. output frequency Rated input voltage and frequency Allowable voltage fluctuation Allowable frequency fluctuation At short-time deceleration At capacitor feedback

3.3 4.5 7.2 10.3 9.6 12.0 19.6 30.0 8.0 11.0 17.5 25.0 Proportional to input voltage: 0..240 V 1000 Hz3 Single-phase 200..240 V 50/60 Hz 3-phase 200..240 V 50/60 Hz -15%..+10% 5%

Braking torque

100%: <50Hz 50%: <60Hz Self cooling

70%: <50Hz 50%: <60Hz

Approx 20% Forced-air-cooling

Cooling method 1. 2. 3.

Single phase model use forced air cooling but three phase model is self cooling. Based on a standard 3-Phase standard motor. Above 400Hz with some function limitation.

400 V class 3G3MX-A4


Motor kW1

Three-phase: MX2@ For VT setting For CT setting 380 VT 380 CT 480 VT

A4004 0.75 0.4 1.3 1.1 1.7 1.4 2.1 1.8

A4007 1.5 0.75 2.6 2.2 3.4 2.8 4.1 3.4

A4015 2.2 1.5 3.5 3.1 4.4 3.9 5.4 4.8

A4022 3.0 2.2 4.5 3.6 5.7

A4030 4.0 3.0 5.7 4.7 7.3

A4040 5.5 4.0 7.3 6.0 9.2

A4055 7.5 5.5 11.5 9.7 14.5

A4075 11 7.5 15.1 11.8 19.1 14.9 23.0 18.0

A4110 15 11 20.4 15.7 25.7 19.9 31.0 24.0

A4150 18.5 15 25.0 20.4 31.5 25.7 38.0 31.0

Output characteristics

Inverter capacity kVA

480 CT Rated output current (A) at VT Rated output current (A) at CT Max. output voltage Max. output frequency Rated input voltage and frequency Allowable voltage fluctuation Allowable frequency fluctuation At short-time deceleration *3 At capacitor feedback

4.5 5.9 7.6 12.3 6.9 8.8 11.1 17.5 5.5 7.2 9.2 14.8 Proportional to input voltage: 0..480 V 1000 Hz2 3-phase 380..480 V 50/60 Hz -15%..+10% 5%

Power supply

Braking torque

100%: <50Hz 50%: <60Hz

Cooling method 1. 2. Based on a standard 3-Phase standard motor. Above 400Hz with some function limitation.

70%: <50Hz 50%: <60Hz Forced-air-cooling

3G3MX2

Specifications
Commom specifications
Model number 3G3MX@ Control methods Output frequency range Control functions Frequency precision Specifications Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, close loop vector with motor feedback, V/F) 0.10..1000.00 Hz (with restrictions above 400Hz)

Digital set value: 0.01% of the max. frequency Analogue set value: 0.2% of the max. frequency (25 10 C) Digital set value: 0.01 Hz Resolution of frequency set value Analogue set value: 1/1000 of maximum frequency Resolution of output frequency 0.01Hz 200% / 0.5Hz Starting torque Overload capability Frequency set value V/f Characteristics Dual rating: Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute 0 to 10 VDC (10K), 4 to 20mA (100), RS485 Modbus, Network options Constant/ reduced torque, free V/f FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (external braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (remote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position deviation clear), ADD (add frequency enable), F-TM (force terminal mode), ATR (permission of torque command input), KHC (Cumulative power clear), MI1~MI7 (general purpose inputs for EzSQ), AHD (analog command hold), CP1~CP3 (multistageposition switches), ORL (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position changeover), GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HLD (retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-phase), DISP (display limitation), OP (option control signal), NO (no function) RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error signal), AL (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time expired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection), DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic output signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warning), LOC (Low load), MO1~MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) performance monitor), OP (option control signal), NO (no function) Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control, torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry, frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR 2 analogue inputs 0 to 10V (10K), 4 to 20mA (100) 0 to 10V (up to 24V), up to 32KHz 0.01 to 3600.0s (line/curve selection), 2nd accel/decel setting available Status indicator LEDs Run, Program, Alarm, Power, Hz, Amps Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency... Electronic Thermal overload relay and PTC thermistor input 200% of rated current Dual rating: Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute 800V for 400V type and 400V for 200V type 345V for 400V type and 172.5V for 200V type Following items are selectable: Alarm, decelerates to stop, decelerates to stop with DC bus controlled, restart Temperature monitor and error detection Stall prevention during acceleration/deceleration and constant speed Detection at power-on On when power is supplied to the control part IP20, Varnish coating on PCB 90% RH or less (without condensation) -20 C..+65 C (short-term temperature during transportation) 10C to 40C Indoor (no corrosive gas, dust, etc.) Max. 1000 m 5.9 m/s2 (0.6G), 10 to 55 Hz

Inputs signals

Functionality Protection functions Ambient conditions

Output signals

Standard functions

Analogue inputs Pulse train input terminal Accel/Decel times Display Motor overload protection Instantaneous overcurrent Overload Overvoltage Undervoltage Momentary power loss Cooling fin overheat Stall prevention level Ground fault Power charge indication Degree of protection Ambient humidity Storage temperature Ambient temperature Installation Installation height Vibration

10

Frequency inverters

Dimensions
W W1
qtm ovq `kl oqf

4.5
rxrcqhud RfRlwQ ?@hmudqsdq ?@hmudqsdq

W W1
qtm g ` ovq `kl oqf

2-d

W W1

2-d

RfRlwQ ?@hmudqsdq ?@hmudqsdq


g `

qtm

rsno qdrds

qtm

rsno qdrds

qtm

ovq `kl oqf

RfRlwQ ?@hmudqsdq ?@hmudqsdq


g

H1 H

H1 H

qtm

rsno qdrds

H1 H

Figure 1 D
D Figure 2

Figure 3
D1 2,6
D1 D2
D1 D

Voltage class

Inverter model MX2@ AB001 AB002 AB004 AB007 AB015 AB022 A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 A4110 A4150

Figure 1 1

W 68

W1 56

H 128

H1 118

Dimensions in mm t D 109 123 170.5

D2

D1 13.5 27 55

D2 -

d -

Single-phase 200 V

1 2
2 2 1 1 1 1 2 2 3 3 3 3 3 2 2 2 2 2 3 3 3 3 3 108 96 128 118

4.4

4.5

109 68 56 128 118 108 140 140 180 220 96 128 122 160 192 128 128 260 296 350 118 118 248 284 336 5 6 7 7 113 146 170.5 170.5 155 175 175 144 108 96 128 118 171 128 140 122 160 128 260 296 118 248 284 5 6 7 171 155 175

13.5 27 50 55 55 73.3 97 84 28 55 55 73.3 97 4.4 6 5 4.5 6 7 -

Three-phase 200 V

4.4 4.4 6 5 5

4.5

6 7 7

Three-phase 400 V

180

Weight (KG) 1.0 1.0 1.1 1.4 1.8 1.8 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.0 3.4 5.1 7.4 1.5 1.6 1.8 1.9 1.9 2.1 3.5 3.5 4.7 5.2

Rasmi footprint Filters 3G3AX-FIM


Rasmi model AX-FIM1010-RE 1x200 V AX-FIM1014-RE AX-FIM1024-RE AX-FIM2010-RE AX-FIM2020-RE 3x200 V AX-FIM2030-RE AX-FIM2060-RE AX-FIM2080-RE AX-FIM2100-RE AX-FIM3005-RE AX-FIM3010-RE 3x400 V AX-FIM3014-RE AX-FIM3030-RE AX-FIM3050-RE 111 111 144 150 182 45 45 50 52 62 169 169 174 306 357 156 156 161 290 330 91 91 120 122 160 M4 M4 M4 M5 M5 Under development Dimensions in mm W 71 111 111 H 45 50 50 L 169 169 169 X 156 156 156 Y 51 91 91 M M4 M4 M4

3G3MX2

11

Option board
30.7

Input AC Reactor 3G3AX-RAI


Voltage Reference AX-RAI02800080-DE AX-RAI00880200-DE AX-RAI00350335-DE AX-RAI00180670-DE AX-RAI07700050-DE AX-RAI03500100-DE AX-RAI01300170-DE AX-RAI00740335-DE
A

200V

400V

120 120 180 180 120 120 120 180

B2 70 80 85 85 70 80 80 85

Dimensions in mm C2 D E 120 80 52 120 80 62 190 140 55 190 140 55 120 80 52 120 80 62 120 80 62 190 140 55

F 5.5 5.5 6 6 5.5 5.5 5.5 6

Weight Kg 1.78 2.35 5.5 5.5 1.78 2.35 2.50 5.5

DC Reactor 3G3ZX-RC
Voltage Reference
AX-RC21400016-RE AX-RC10700032-RE AX-RC06750061-RE AX-RC03510093-RE AX-RC02510138-RE A

C 96

Dimensions in mm D E F G

Weight Kg 1.22

84

113

105

101

66

7.5

1.60 1.95 3.20 5.20 6.00 11.4 14.3 1.22

200V

AX-RC01600223-RE AX-RC01110309-RE AX-RC00840437-RE AX-RC00590614-RE AX-RC00440859-RE AX-RC43000020-RE AX-RC27000030-RE AX-RC14000047-RE AX-RC10100069-RE

108 120 150

116 135 124 120 136 152 135 146 160 177 182. 160 6 96 113 105 101 116 135 133 120 136 152 135 146 160 177 182. 160 6

82 94

6.5 9.5 7

9.5

115

84 108 120 150

66 82 94 115

5 6.5 7 7

7.5

2 9.5

1.60 1.95 3.70 5.20 6.00 11.4 14.3

400V

AX-RC06400116-RE AX-RC04410167-RE AX-RC03350219-RE AX-RC02330307-RE AX-RC01750430-RE

9.5 2

Output AC Reactor 3G3AX-RAO


Voltage Reference AX-RAO11500026-DE AX-RAO07600042-DE AX-RAO04100075-DE AX-RAO03000105-DE AX-RAO01830180-DE AX-RAO01150220-DE AX-RAO00950320-DE AX-RAO00630430-DE AX-RAO00490640-DE
A

200V

120 120 120 120 180 180 180 180 180

B2 70 70 80 80 85 85 85 95 95

Dimensions in mm C2 D E 120 80 52 120 80 52 120 80 62 120 80 62 190 140 55 190 140 55 205 140 55 205 140 65 205 140 65

F 5.5 5.5 5.5 5.5 6 6 6 6 6

Weight Kg 1.78 1.78 2.35 2.35 5.5 5.5 6.5 9.1 9.1

12

Frequency inverters

Voltage

Reference AX-RAO16300038-DE AX-RAO11800053-DE AX-RAO07300080-DE AX-RAO04600110-DE AX-RAO03600160-DE AX-RAO02500220-DE AX-RAO02000320-DE

400V

120 120 120 180 180 180 180

B2 70 80 80 85 85 95 105

Dimensions in mm C2 D E F 120 80 52 5.5 120 80 52 5.5 120 80 62 5.5 190 140 55 6 205 140 55 6 205 140 55 6 205 140 85 6

Weight Kg 1.78 2.35 2.35 5.5 6.5 9.1 11.7


X

Chokes 3G3AX-FEJ
Reference AX-FEJ2102-RE AX-FEJ2515-RE AX-FEJ5045-RE D diameter 21 25 50 Motor KW < 2.2 < 15 < 45 L 85 105 150 W 22 25 50 Dimensions in mm H X Y 46 70 62 90 110 125 30 m 5 5 5 Weight Kg 0.1 0.2 0.7
H W Y

m L

Resistor Dimensions 3G3AX-REM


AX-REM00K1200
Fig 1

Fig 2

Fig 3

Fig 4

Type AX-REM00K1400-IE AX-REM00K2070-IE AX-REM00K2120-IE AX-REM00K2200-IE AX-REM00K4075-IE AX-REM00K4035-IE AX-REM00K4030-IE AX-REM00K5120-IE AX-REM00K6100-IE AX-REM00K6035-IE AX-REM00K9070-IE AX-REM00K9017-IE AX-REM01K9070-IE AX-REM01K9017-IE AX-REM02K1070-IE AX-REM02K1017-IE AX-REM03K5035-IE AX-REM03K5010-IE

Fig. L H

Dimensions in mm M I T

Weight KG

105

27

36

94

0.2

200 260 320

27 27 27 62 73 100 100

36 36 36 100 105 240 240

189 249 309 74 350 295 350

70 210 210

0.425 0.58 0.73 1.41 4 7 8

2 3

200 365 310

4 365

3G3MX2

13

Standard connections
Breaker, MCCB or GFI

Power source, 3-phase or 1-phase, per inverter model

R
(L1)

3G3MX2

U(T1)
Motor

S
(L2)

V(T2) W(T3)

T
N(L3)

Intelligent inputs, 7 terminals

24V

PD/+1 P/+ RB N/Brake resistor (optional)

DC reactor (optional)

P24

+-

NOTE: For the wiring of intelligent I/O and analog inputs, be sure to use twisted pair/ shielded cable. Attach the shielded wire for each signal to its respective common terminal at the inverter end only. Input impedance of each intelligent input is 4.7k

Forward 1 2 3/GS1 4/GS2 5/PTC 6 7/EB


[5] configurable as discrete input or thermistor input Output circuit Input circuits

Braking unit (optional)

AL1 AL0 AL2

Relay contacts, type 1 Form C

Open collector output Freq. arrival signal

Thermistor Short bar (Source type) GND for logic inputs

11/EDM

Load

PLC

L
L

12

Load

+ CM2
) Termination resistor (200) (Change by slide switch) L RS485 transceiver L L 10Vdc GND for logic outputs

Meter

EO
Meter

SP
Serial communication port (RS485/ModBus)

AM
Analog reference 0~10VDC 4~20mA Pulse train input 24Vdc 32kHz max.

SN
RJ45 port (Optional operator port) USB (mini-B) port (PC communication port) USB power: Self power Option port connector

H O OI
Apprx.10k Apprx.100 L

+ -

RS485 transceiver L USB transceiver

EA L
GND for analog signals L L

L Option port controller L

Terminal Block Specifications


Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 PD/+1, P/+ P/+, N/P/+, RB Inverter output External DC reactor terminal Regenerative braking unit terminal Braking resistor terminals Grounding Name Main circuit power supply input Function (signal level) Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal S/L2 is not available for these units Used to connect the motor Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/ +2 when a DC reactor is connected. Connect optional regenerative braking units (If a braking torque is required) Connect option braking resistor (if a braking torque is required) For grounding (grounding should conform to the local grounding code.)

14

Frequency inverters

Control Circuit
Type No. PLC P24 1 Digital input signals 2 3/ST1 4/ST2 5/PTC 6 7/EB L Pulse train EA EO H O OI L 11/EDM Digital output signals 12 CMD AL0 AL1 AL2 Comms Monitor Signal AM SP Serial communication terminal SN RS485 Modbus communication Signal name Intelligent input common Internal 24 VDC Multi-function Input selection 1 Multi-function Input selection 2 Multi-function Input selection 3 / safe stop input 1 Multi-function Input selection 4 / safe stop input 2 Multi-function Input selection 5 / PTC thermistor input Multi-function input selection 6 Multi-function input selection 7 / Pulse train input B Multi-function Input selection common (in upper row) Pulse train input A Pulse train output Frequency reference power supply Voltage frequency reference signal Current frequency reference signal Frequency reference common (bottom row) Discrete logic output 1 / EDM output Discrete logic output 2 GND logic output Relay commom contact Relay contact, normally open Relay contact, normally closed Analog voltage output Function Source type: connecting [P24] to [1]-[7] turns inputs ON Sink type: connecting [L] to [1]-[7] turns inputs ON 24 VDC, 30mA Factory setting: Forward/ Stop Factory setting: Reverse/ Stop Factory setting: External trip Factory setting: Reset Factory setting: Multi-step speed reference 1 Factory setting: Multi-step speed reference 2 Factory setting: Jog -Factory setting: Speed reference LAD frequency 10 V DC 10mA max 0 to 10V DC (10K) 4 to 20mA (250) -Factory setting: During Run Factory setting: Frequency arrival type 1 -Factory setting: Alarm signal Under normal operation AL1 - AL0 Closed AL2 - AL0 Open R load 250VAC 2.5A 30VDC 3.0 A I load 250VAC 0.2A 30VDC 0.7A 0 to 10VDC 1mA 27 VDC, 50mA max EDM based on ISO13849-1 -32KHz max 5 to 24VDC 10VDC 2mA 32KHz max 27 VDC max Signal level 24VDC, 30mA

Analog input signal

Factory setting: LAD frequency

Side by side mounting


Enclosure

Inverter heat loss Three-phase 200 V class


Model 3G3MX2 200 VT Inverter 200 CT capacity 240 VT kVA 240 CT Rated current (A) VT Rated current (A) CT Total heat loss Efficiency at rated load Cooling Method A2001 0.4 0.2 0.4 0.3 1.2 1.0 12 89.5 A2002 A2004 0.6 1.2 0.5 1.0 0.7 1.4 0.6 1.2 1.9 3.4 1.6 3.0 22 30 90 93 Self cooling A2007 2.0 1.7 2.4 2.0 6.0 5.0 48 94 A2015 3.3 2.7 3.9 3.3 9.6 8.0 79 95 A2022 4.1 3.8 4.9 4.5 12.0 11.0 104 95.5 A2037 6.7 6.0 8.1 7.2 19.6 17.5 154 96 A2055 10.3 8.6 12.4 10.3 30.0 25.0 229 96 A2075 13.8 11.4 16.6 13.7 40.0 33.0 313 96 A2110 19.3 16.2 23.2 19.5 56.0 47.0 458 96 A2150 23.9 20.7 28.6 24.9 69.0 60.0 625 96

Forced-air-cooling

3G3MX2

15

Single-phase 200 V class 3G3MX2-AB


Model MX2 200V VT Inverter 200V CT capacity 240V VT kVA 240V CT Rated current (A) VT Rated current (A) CT Total heat loss Efficiency at rated load Cooling Method AB001 0.4 0.2 0.4 0.3 1.2 1.0 12 89.5 AB002 0.6 0.5 0.7 0.6 1.9 1.6 22 90 Self cooling AB004 1.2 1.0 1.4 1.2 3.4 3.0 30 93 AB007 2.0 1.7 2.4 2.0 6.0 5.0 48 94 AB015 3.3 2.7 3.9 3.3 9.6 8.0 79 95 AB022 4.1 3.8 4.9 4.5 12.0 11.0 104 95.5

Forced-air-cooling
A4022 4.5 3.6 5.7 4.5 6.9 5.5 116 95 A4030 5.7 4.7 7.3 5.9 8.8 7.2 125 96 A4040 7.3 6.0 9.2 7.6 11.1 9.2 167 96 A4055 11.5 9.7 14.5 12.3 17.5 14.8 229 96 A4075 15.1 11.8 19.1 14.9 23.0 18.0 296 96.2 A4110 20.4 15.7 25.7 19.9 31.0 24.0 411 96.4 A4150 25.0 20.4 31.5 25.7 38.0 31.0 528 96.6

Three-phase 400 V class 3G3MX2-A4


Inverter capacity kVA Model MX2 380V VT 380V CT 480V VT 480V CT Rated current (A) VT Rated current (A) CT Total heat loss Efficiency at rated load Cooling Method A4004 A4007 1.3 2.6 1.1 2.2 1.7 3.4 1.4 2.8 2.1 4.1 1.8 3.4 35 56 92 93 Self cooling A4015 3.5 3.1 4.4 3.9 5.4 4.8 96 94

Forced-air-cooling
AC reactor MX2 X Y Z R/L1 S/L2 T/L3

Input AC Reactor 3G3AX-RAI


Power supply MCCB U V W

Max. applicable motor output kW 1.5 3.7 7.5 15

3 phase 200 V class Current value A AX-RAI02800080-DE 8.0 AX-RAI00880200-DE 20.0 AX-RAI00350335-DE 33.5 AX-RAI00180670-DE 67.0 Reference

Inductance mH 2.8 0.88 0.35 0.18

Max. applicable motor output kW 1.5 4.0 7.5 15

400 V class Current value A 5.0 AX-RAI07700050-DE AX-RAI03500100-DE 10.0 17.0 AX-RAI01300170-DE 33.5 AX-RAI00740335-DE Reference

Inductance mH 7.7 3.5 1.3 0.74

DC Reactor 3G3AX-RC
MX2 Power supply MCCB R/L1 S/L2 T/L3

+1

P/+2

DC reactor

Max. applicable motor output kW 0.2 0.4 0.7 1.5 2.2 3.7 5.5 7.5 11.0 15.0

200 V class Current value A AX-RC21400016-RE 1.6 AX-RC10700032-RE 3.2 AX-RC06750061-RE 6.1 AX-RC03510093-RE 9.3 AX-RC02510138-RE 13.8 AX-RC01600223-RE 22.3 AX-RC01110309-RE 30.9 AX-RC00840437-RE 43.7 AX-RC00590614-RE 61.4 AX-RC00440859-RE 85.9 Reference

Inductance mH 21.4 10.7 6.75 3.51 2.51 1.60 1.11 0.84 0.59 0.44

Max. applicable motor output kW 0.4 0.7 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0

400 V class Current value A 2.0 AX-RC43000020-RE AX-RC27000030-RE 3.0 4.7 AX-RC14000047-RE AX-RC10100069-RE 6.9 AX-RC08250093-RE 9.3 AX-RC06400116-RE 11.6 AX-RC04410167-RE 16.7 AX-RC03350219-RE 21.9 AX-RC02330307-RE 30.7 AX-RC01750430-RE 43.0 Reference

Inductance mH 43.0 27.0 14.0 10.1 8.25 6.40 4.41 3.35 2.33 1.75

Output AC Reactor 3G3AX-RAO


Max. applicable motor output kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 200 V class Current value A AX-RAO11500026-DE 2.6 AX-RAO07600042-DE 4.2 AX-RAO04100075-DE 7.5 AX-RAO03000105-DE 10.5 AX-RAO01830160-DE 16.0 AX-RAO01150220-DE 22.0 AX-RAO00950320-DE 32.0 AX-RAO00630430-DE 43.0 AX-RAO00490640-DE 64.0 Reference Inductance mH 11.50 7.60 4.10 3.00 1.83 1.15 0.95 0.63 0.49 Max. applicable motor output kW 1.5 2.2 4.0 5.5 7.5 11 15 Reference 400 V class Current value A 3.8 5.3 8.0 11.0 16.0 22.0 32.0 Inductance mH 16.30 11.80 7.30 4.60 3.60 2.50 2.00

AX-RAO16300038-DE AX-RAO11800053-DE AX-RAO07300080-DE AX-RAO04600110-DE AX-RAO03600160-DE AX-RAO02500220-DE AX-RAO02000320-DE

16

Frequency inverters

Ordering information
Power Supply

B
USB Cable

E
CX-Drive CX-One

MCCB

A
Input AC Reactor

B
Remote Operator Extansion Cable

B
LCD 5 lines Remote Operator

A
Filter

C
Communication option

3G3MX2

D
Braking Resistor

A
Choke

A
DC Reactor

Motor

A
Output AC Reactor

Ground

3G3MX2
Specifications Variable torque Constant torque Max motor kW Rated current A Max motor kW Rated current A 0.1 0.2 Single-phase 200 V 0.4 0.75 1.5 2.2 0.1 0.2 0.4 0.75 1.5 Three-phase 200 V 2.2 3.7 5.5 7.5 11 15 0.4 0.75 1.5 2.2 Three-phase 400 V 3.0 4.0 5.5 7.5 11 15 1.0 1.6 3.0 5.0 8.0 11.0 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0 0.2 0.4 0.55 1.1 2.2 3.0 0.2 0.4 0.55 1.1 2.2 3.0 5.5 7.5 11 15 18.5 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 1.2 1.9 3.5 6.0 9.6 12.0 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0 Model Standard 3G3MX2-AB001-E 3G3MX2-AB002-E 3G3MX2-AB004-E 3G3MX2-AB007-E 3G3MX2-AB015-E 3G3MX2-AB022-E 3G3MX2-A2001-E 3G3MX2-A2002-E 3G3MX2-A2004-E 3G3MX2-A2007-E 3G3MX2-A2015-E 3G3MX2-A2022-E 3G3MX2-A2037-E 3G3MX2-A2055-E 3G3MX2-A2075-E 3G3MX2-A2110-E 3G3MX2-A2150-E 3G3MX2-A4004-E 3G3MX2-A4007-E 3G3MX2-A4015-E 3G3MX2-A4022-E 3G3MX2-A4030-E 3G3MX2-A4040-E 3G3MX2-A4055-E 3G3MX2-A4075-E 3G3MX2-A4110-E 3G3MX2-A4150-E

Voltage class

3G3MX2

17

A Line filters
Inverter Voltage 1-Phase 200 VAC Model MX2-@ AB001 / AB002 / AB004 AB007 AB015 / AB022 A2001 / A2002 / A2004 / A2007 A2015 / A2022 3-Phase 200 VAC A2037 A2055 / A2075 A2110 A2150 A4004 / A4007 3-Phase 400 VAC A4015 / A4022 / A4030 A4040 A4055 / A4075 A4110 / A4150 Line filter Rasmi Reference AX-FIM1010-RE AX-FIM1014-RE AX-FIM1024-RE AX-FIM2010-RE AX-FIM2020-RE AX-FIM2030-RE AX-FIM2060-RE AX-FIM2080-RE AX-FIM2100-RE AX-FIM3005-RE AX-FIM3010-RE AX-FIM3014-RE AX-FIM3030-RE AX-FIM3050-RE Rated current (A) 10 14 24 10 20 30 60 80 100 5 10 14 23 50

A Input AC Reactors
Inverter Voltage Model MX2-@ A2002 / A2004 / A2007 3-Phase 200 VAC A2015 / A2022 / A2037 A2055 / A2075 A2110 / A2150 AB002 / AB004 1-Phase 200 VAC AB007 AB015 / AB022 A4004 / A4007 / A4015 3-Phase 400 VAC A4022 / A4030 / A4040 A4055 / A4075 A4110 / A4150 AX-RAI07700050-DE AX-RAI03500100-DE AX-RAI01300170-DE AX-RAI00740335-DE Under development AC Reactor Reference AX-RAI02800080-DE AX-RAI00880200-DE AX-RAI00350335-DE AX-RAI00180670-DE

A DC Reactors
Inverter 200V single phase DC Reactor AX-RC10700032-RE AX-RC06750061-RE AX-RC03510093-RE AX-RC02510138-RE AX-RC01600223-RE 200V 3-phase Inverter MX2-A2001 MX2-A2002 MX2-A2004 MX2-A2007 MX2-A2015 MX2-A2022 MX2-A2037 MX2-A2055 MX2-A2075 MX2-A2011 MX2-A2015 DC Reactor AX-RC21400016-RE AX-RC10700032-RE AX-RC06750061-RE AX-RC03510093-RE AX-RC02510138-RE AX-RC01600223-RE AX-RC01110309-RE AX-RC00840437-RE AX-RC00590614-RE AX-RC00440859-RE Inverter MX2-A4004 MX2-A4007 MX2-A4015 MX2-A4022 MX2-A4030 MX2-A4040 MX2-A4055 MX2-A4075 MX2-A4011 MX2-A4015 400V 3-phase DC Reactor AX-RC43000020-RE AX-RC27000030-RE AX-RC14000047-RE AX-RC10100069-RE AX-RC08250093-RE AX-RC06400116-RE AX-RC04410167-RE AX-RC03350219-RE AX-RC02330307-RE AX-RC01750430-RE -

MX2-AB001 MX2-AB002 MX2-AB004 MX2-AB007 MX2-AB015 MX2-AB022

A Chokes
Model AX-FEJ2102-RE AX-FEJ2515-RE AX-FEJ5045-RE Diameter 21 25 50 Description For 2.2 KW motors or below For 15 KW motors or below For 45 KW motors or below

A Output AC Reactor
Inverter Voltage Model MX2-@ A2001 / A2002 / A2004 AB001 / AB002 / AB004 A2007/AB007 A2015 / AB015 200 VAC A2022 / AB022 A2037 A2055 A2075 A4004 / A4007 / A4015 A4022 400 VAC A4030 / A4040 A4055 A4075 AC Reactor Reference AX-RAO11500026-DE AX-RAO07600042-DE AX-RAO04100075-DE AX-RAO03000105-DE AX-RAO01830160-DE AX-RAO01150220-DE AX-RAO00950320-DE AX-RAO16300038-DE AX-RAO11800053-DE AX-RAO07300080-DE AX-RAO04600110-DE AX-RAO03600160-DE

B Accessories
Types Digital operator Model 3G3AX-OP05 3G3AX-CAJOP300-EE Description LCD remote operator Remote operator cable Functions 5 Line LCD remote operator with copy function, cable length max. 3m. 3 meters cable for connecting remote operator

Accessories

AX-PCUSB-E

PC configuration cable

Mini USB to USB connector cable

18

Frequency inverters

C Communication option boards


Types Model 3G3AX-MX2-PRT Communication options 3G3AX-MX2-DRT 3G3AX-MX2-ERT 3G3AX-MX2-CRT 3G3AX-MX2-ML2 3G3AX-MX2-CORT Description Profibus option card DeviceNet option card EtherCAT option card CompoNet option card Mechatrolink-II option card CanOpen option card Under development Functions Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through Profibus communications with the host controller.

D Braking unit, braking resistor unit


Inverter Voltage Max. motor kW 0.12 0.25 0.55 1.1 200 V (single-/ threephase) 1.5 2.2 4.0 5.5 7.5 11 15 0.55 1.1 1.5 2.2 400 V (threephase) 3.0 4.0 5.5 7.5 11 15 Inverter MX2@ 3-phase 1-phase 2001 2002 2004 2007 2015 2022 2037 2055 2075 2110 2150 4004 4007 4015 4022 4030 4040 4055 4075 4110 4150 B001 B002 B004 B007 B015 B022 35 70 100 180 50 REM00K2070-IE 35 20 17 10 REM00K4075-IE REM00K4035-IE REM00K6035-IE REM00K9017-IE REM00K1400-IE REM00K1200-IE REM00K2200-IE REM00K2120-IE REM00K4075-IE REM00K6100-IE REM00K9070-IE 70 75 35 35 17 400 200 200 120 75 100 70 100 Connectable min. resistance Inverter mounted type (3 %ED, 10 sec max) Type AXREM00K1400-IE REM00K1200-IE Resist 400 200 Braking resistor unit Braking torque % 200 180 180 100 140 90 50 75 55 40 55 200 200 190 130 160 120 140 100 50 55 Inverter mounted type (10%ED, 10 sec max) Type AXREM00K1400-IE REM00K1200-IE REM00K2070-IE REM00K4075-IE REM00K4035-IE REM00K6035-IE REM00K9017-IE REM01K9017-IE REM02K1017-IE REM03K5010-IE REM00K1400-IE REM00K2200-IE REM00K5120-IE REM00K6100-IE REM00K9070-IE REM01K9070-IE REM02K1070-IE REM03K5035-IE Resist 400 200 70 75 35 35 17 17 17 10 400 200 120 100 70 70 70 35 Braking torque % 200 180 180 200 130 180 100 150 110 75 95 200 200 190 200 160 140 150 110 75 110

E Computer software
Types Software Model CX-Drive CX-One Description Computer software Computer software Installation Configuration and monitoring software tool Configuration and monitoring software tool

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I113E-EN-01 In the interest of product improvement, specifications are subject to change without notice.

3G3MX2

19

OMRON ELECTRONICS LLC THE AMERICAS HEADQUARTERS

OMRON CANADA, INC. HEAD OFFICE

OMRON ARGENTINA SALES OFFICE

OMRON ELETRNICA DO BRASIL LTDA HEAD OFFICE

OMRON CHILE SALES OFFICE

OMRON ELECTRONICS MEXICO SA DE CV HEAD OFFICE

OTHER OMRON LATIN AMERICA SALES

Cat. No. I113E-EN-01

Specifications are subject to change without notice.

2009 Omron Electronics LLC

You might also like