You are on page 1of 6

April 1, 2011

Foam 138a

TECHNICAL DATA

WATEr PoWErED oSCILLATINg MoNITorS

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

1. DESCrIPTIoN

Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use in high risk areas such as tank farm facilities, aircraft hangars, offshore, refineries, chemical plants, and heliports.

Features

The monitor and body of the oscillating unit are manufactured of brass. The water drive wheel is bronze with bronze supply gate valve. CWPOM is UL Listed with CMNB350, CMNB500 and CMNB750 monitor nozzles only Capable of flowing foam or water Unique water drive wheel design Arc of oscillation adjustable via 6 set points Speed of oscillation adjustable from 0-30/sec. (24 / sec. @100 psi) (7 Bar) Manual override capabilities in both horizontal and vertical degree fields Minimum operating pressure 40 psi (2.8 Bar) Maximum operating pressure 200 psi (14 Bar) Flow of water / foam solution through water drive wheel: - At 50 psi (3.5 Bar) 5 gpm (19 lpm) - At 100 psi (7 Bar) 8 gpm (30 lpm) Double reduction oil bath gearbox Grease fittings and two rows of stainless steel ball bearings at all rotation joints on monitor All brass and stainless steel construction Monitor has one tiller bar control for manual control Unit equipped with a garden hose test connection. This allows functional check of the oscillation mechanism without system flow.

2. LISTINgS AND APProVALS


See Tables 1 & 2.

3. TECHNICAL DATA
Specifications:
See Tables 1 & 2. See Table 1. See Table 2.

Material Standards: ordering Information:

Viking Technical Data may be found on The Viking Corporations Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page.

4. INSTALLATIoN

The vertical angle of elevation and horizontal arc of oscillation is field adjustable and can be set and locked in position. The monitor can be set to oscillate over a range of 0-120 and the oscillation arc can be set anywhere within the 360 field of operation. Elevation range of the unit is between +80 and -40 from the horizontal plane. A water drive wheel connected to a double reduction gearbox drives the oscillating mechanism. To operate the drive wheel, a small quantity of flow is diverted from the monitor inlet. The monitor requires no external wiring or hydraulic control for operation. The drive wheel design is unique in that it does not require an inlet filter. This makes the oscillating mechanism highly reliable and less likely to fail. NoTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPC, and VdS which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing and inspection requirements which must be followed. WArNINg: Any system maintenance or testing which involves placing a control valve or detection system out of service may eliminate the Fire Protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a Fire Patrol in the affected area. Replaces page 138a-e, dated June 1, 2008. (Added data for Part No. F15316 in Table 2.)

5. oPErATIoN

6. INSPECTIoNS, TESTS AND MAINTENANCE

Form No. F_051008

Foam 138b

April 1, 2011

TECHNICAL DATA

WATEr PoWErED oSCILLATINg MoNITorS

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

7. AVAILAbILITy

Viking Foam Products are available through a network of domestic and international distributors. See the Viking web site for closest distributor or contact The Viking Corporation. For details of warranty, refer to Vikings current list price schedule or contact Viking directly. Table 1: Oscillating Monitor Base Specifications Part No. F150484 F150495 Inlet Diameter1 4 4 Discharge Diameter2 2-1/2 3-1/2 Waterway Diameter 3 (76 mm) 4 (100 mm) Maximum Flow3 1250 GPM (4740 LPM) 2000 GPM (7570 LPM) Weight 120 lbs. (54 kg) 150 lbs. (68 kg) Material Brass and Stainless Steel Brass and Stainless Steel

8. guArANTEE

1 2

Monitor inlets are ANSI Class 150 Flat Face flanges. Monitor discharges are male NST Threads. 3 Flow ratings are given for 100 psi (7 bar). Maximum operating pressure is 200 psi (14 bar). 4 Used in assemblies with flow up to and including 1250 GPM. 5 Used in assemblies with flow between 1300 and 2000 GPM.

April 1, 2011

Foam 138c

TECHNICAL DATA

WATEr PoWErED oSCILLATINg MoNITorS

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

Figure 1: Dimensions
Part Number F15048 F15049 A 13 (33 mm) 14.5 (37 mm) b 17 (43 mm) 18.8 (48 mm) C 8 (20 mm) 8 (20 mm) D 3 (8 mm) 3 (8 mm) E 11 (28 mm) 11 (28 mm) F 23 (58 mm) 23 (58 mm) g 14 (36 mm) 14 (36 mm)

Foam 138d

April 1, 2011

TECHNICAL DATA

WATEr PoWErED oSCILLATINg MoNITorS

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

Figure 2: Pressure Loss vs. Flow F15048 Monitor

Figure 3: Pressure Loss vs. Flow F15049 Monitor

April 1, 2011

Foam 138e

TECHNICAL DATA

WATEr PoWErED oSCILLATINg MoNITorS

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

Table 2: Assembly Specifications


Monitor Inlet Pressure Viking Part Number Includes base (See Table 1) Chemguard Model Number Listings Flow rate Monitor Elevation Angle 50 psi (3.45 bar) Fixed reach 5 F15050 CWPOM-350 UL Listed* 350 GPM (1325 LPM) 15 30 5 F15051 CWPOM-500 UL Listed* 500 GPM (1893 LPM) 15 30 5 F15052 F15048 CWPOM-750 UL Listed* 750 GPM (2839 LPM) 15 30 5 F15316 CWPOM-1000 UL Listed* 1000 GPM (3785 LPM) 15 30 5 F15053 CWPOM-1250 UL Listed* 1250 GPM (4732 LPM) 15 30 5 F15317 CWPOM-1300 None 1300 GPM (4921 LPM) 15 30 5 F15318 CWPOM-1400 None 1400 GPM (5300 LPM) 15 30 5 F15319 CWPOM-1500 None 1500 GPM (5678 LPM) 15 30 5 F15320 F15049 F15321 CWPOM-1700 None 1700 GPM (6435 LPM) CWPOM-1600 None 1600 GPM (6057 LPM) 15 30 5 15 30 5 F15322 CWPOM-1800 None 1800 GPM (6814 LPM) 15 30 5 F15323 CWPOM-1900 None 1900 GPM (7192 LPM) 15 30 5 F15054 CWPOM-2000 None 2000 GPM (7571 LPM) 15 30 60 ft. 90 ft. 100 ft. 65 ft. 95 ft. 105 ft. 70 ft. 98 ft. 115 ft. 70 ft. 95 ft. 120 ft. 75 ft. 100 ft. 130 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 85 ft. 115 ft. 150 ft. Height 8 ft. 15 ft. 25 ft. 9 ft. 16 ft. 26 ft. 10 ft. 16 ft. 28 ft. 10 ft. 16 ft. 27 ft. 11 ft. 16 ft. 28 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 12 ft. 18 ft. 32 ft. oscillating reach 55 ft. 80 ft. 90 ft. 60 ft. 85 ft. 95 ft. 65 ft. 88 ft. 98 ft. 65 ft. 85 ft. 100 ft. 70 ft. 90 ft. 110 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 80 ft. 105 ft. 130 ft. Height 8 ft. 14 ft. 23 ft. 9 ft. 15 ft. 24 ft. 10 ft. 16 ft. 25 ft. 10 ft. 16 ft. 25 11 ft. 167 ft. 27 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 11 ft. 16 ft. 28 ft. 100 psi (6.9 bar) Fixed reach 110 ft. 135 ft. 145 ft. 115 ft. 155 ft. 165 ft. 120 ft. 155 ft. 170 ft. 125 ft. 155 ft. 200 130 ft. 165 ft. 225 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 140 ft. 180 ft. 260 ft. Height 10 ft. 20 ft. 32 ft. 10 ft. 23 ft. 36 ft. 11 ft. 23 ft. 36 ft. 11 ft. 24 ft. 38 ft. 11 ft. 25 ft. 38 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 12 ft. 26 ft. 43 ft. oscillating reach 100 ft. 125 ft. 135 ft. 105 ft. 145 ft. 150 ft. 105 ft. 146 ft. 150 ft. 107 ft. 136 ft. 170 ft. 115 ft. 150 ft. 195 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 125 ft. 165 ft. 220 ft. Height 9 ft. 18 ft. 30 ft. 9 ft. 21 ft. 33 ft. 11 ft. 21 ft. 33 ft. 11 ft. 22 ft. 35 ft. 11 ft. 24 ft. 35 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 12 ft. 25 ft. 40 ft. 150 psi (10.3 bar) Fixed reach 135 ft. 170 ft. 175 ft. 150 ft. 185 ft. 200 ft. 160 ft. 185 ft. 210 ft. 165 ft. 190 ft. 225 ft. 168 ft. 195 ft. 230 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 180 ft. 210 ft. 275 ft. Height 12 ft. 23 ft. 39 ft. 13 ft. 25 ft. 44 ft. 14 ft. 25 ft. 45 ft. 14 ft. 25 ft. 46 ft. 14 ft. 25 ft. 46 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 15 ft. 27 ft. 50 ft. oscillating reach 120 ft. 150 ft. 155 ft. 135 ft. 165 ft. 180 ft. 140 ft. 168 ft. 183 ft. 145 ft. 170 ft. 190 ft. 145 ft. 170 ft. 195 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 160 ft. 190 ft. 240 ft. Height 10 ft. 21 ft. 35 ft. 11 ft. 23 ft. 40 ft. 13 ft. 23 ft. 42 ft. 13 ft. 23 ft. 43 ft. 13 ft. 24 ft. 44 ft. ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** 14 ft. 26 ft. 48 ft.

* uL LIsted with Chemguard C301 MS (Viking Part Number F14971) ** Data not currently available

ThIS PAGE INTENTIONAlly lEFT blANk

Form No. F_051008

Replaces page 138a-e, dated June 1, 2008. (Added data for Part No. F15316 in Table 2.)