You are on page 1of 10

PS1800 Centrifugal Pumping Systems

General Data and Sizing Tables


The curve show the performance range of 4 models at 1800Wp solar
array

- irradiation of 6kWh/m² on a tilted surface


- ambient temperature 30°C

Solar tracking will improve performance by aprox 40% in summer


month´s

Application:
- drinking water supply
- livestock watering
- pond management
- irrigation
- village water supply

Solar Pumping System / Capacity Diagram


6kWh/m²/day, 1800Wp solar array
Pump Lift Range
60 SJ12-3 5- 15m head / 50ft
meter head

SJ8-5 10- 25m head / 83ft


SJ5-8 15- 35m head / 115ft
SJ5-12 40- 65m head / 215ft
50
SJ5-12 Curve is based on
Irradiation 6kWh/m² day, tilted surface

40 Pump ends:
SJ-xx = centrifugal pump

Motor:
30 brushless DC, maintenance free
SJ5-8
LORENTZ offers standard solar pump
solutions up to 230m (760ft) head and
20 special solutions up to 750m (2500ft)
SJ8-5 head. Ask for charts

SJ12-3
10

0
20 40 60 80 100 120 140 160
Ver. 070723 m³/day
Motor ECDRIVE 1200 HR / C
Controller PS1800
• brushless DC motor
• controlling of the pump system and monitoring of the operating • no electronics inside motor
states • water filled
• mounted at surface (no submerged electronic parts) • IP68, pressure balanced, max. submersion unlimited
• two control inputs for well probe (dry running protection), float • dynamic slide bearings, material: carbon/ceramic
or pressure switches, remote control etc. • wetted material: stainless steel (AISI 316), POM, rubber,
• automatic reset 20 minutes after well probe turns pump off cable drinking water approved
• protected against reverse polarity, overload and high
temperature Pump End (PE)
• speed control, max. pump speed adjustable to reduce flow rate • high life expectancy
to approx. 30 % • none-return valve
• solar operation: integrated MPPT (Maximum Power Point • dry running protection (optional)
Tracking) • material: stainless steel (AISI 316)
• battery operation: low voltage disconnect and restart after
battery has recovered Errors excepted and possible alterations without prior notice
• max. efficiency 92 % (motor + controller)
• enclosure: IP 54 (sealed, weatherproof)
Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ5-12
C-SJ5-12
Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)


- 11h standard solar day
- ambient average temperature of 30°C
US - 1% cable loss
GPD m³/day 40/132 Head Metres /Ft.
13000 50

12000
45 50/165

11000
40
10000 60/197

9000
35
70/230
8000 30
7000
25
6000
20
5000

4000 15
3000
10
2000
5
1000

Wp
700
800
900
1000
1100
1200
1300
1400
2 3 4 5 6 7 8 9
1500
1600
1700
1800
1900
2000
2100
2200
Irradiation on a tilted surface kWh/m²/day

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Internet: www.Lorentz.de
Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-12.dwg Rev. Jul. 2007
PS1800 C-SJ5-12 (Item No. 1163) for Solar Operation
(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
6 40 m / 131 ft
System Performance
50 m / 164 ft
1400

5
Instantaneous Output Average Values 60 m / 197 ft
1200

4 70 m / 230 ft
> 50% Efficiency 1000

flow rate [US gal/h]


flow rate [m³/h]

3 800

600
2

> 45% Efficiency 400

1
200
Efficiency = Product of Controller x Motor
x Pump end efficiency
0 0
0 200 400 600 800 1000 1200 1400 1600 1800
DC Power [W]

Dimensions [mm] Minimum Internal Diameter


Pump Type Weight
A B C D Emax BSP of Borehole
SJ 5A-12 612 186 426 96 98 1 1/2" 4" (104mm) 13,5 kg

System Performance
An irradiation value and the required head in meters are Motor
given for a certain solar pumping system. The LORENTZ submersible motor, type EC 1200-C is a 2
By connecting the point for the power output in Wp of the pole synchronous brushless DC motor. Slide ring bearing
solar array with an irradiation value, move vertical and ceramic trust bearings are water lubricated.
upwards to the intersection with the required head curve, The motor raw earth magnets are hermetically sealed in
then horizontal to the left to find the daily quantity of stainless steel and encapsulated in synthetic resin.
water that can be pumped ( m³/day) The motor is pressure compensated and there are no
practical depth limitations for submergence.
Or the other way: No electronics are inside the motor and the entire motor is
water filled.
By starting from the daily required water amount
horizontally to the intersection of the required head, then Data:
vertically down to the intersection with the expected Voltage: 3 X 100V electronically commutated
solar irradiation, then horizontally to the left to find the Power: 1,6kW / 2,2HP
required output of the solar array. Efficiency: 92% max

Instantaneous Output Controller


From the above curves, the maximum quantity of water Mounted at surface,
in m³/h for a given solar array size in Wp and head in Well probe and float switch terminals
meters / ft can be found. Add at least 25% to the DC MPPT ( max. power point tracking)
power to account for dirt, heat and other losses of the Overload, temperature and reverse polarity protected
solar array. Pump Speed control from 30% to full
LED indicate status, pump speed water level, overload etc.
Pump
Centrifugal multistage direct coupled on a LORENTZ 6 to 8 standard 12V modules can be connected in series.
brushless submersible motor. The pump is made from E.g. nom. Voltage 72 to 96V, max system Voltage Umax=
stainless steel with water lubricated rubber bearings. A 200V. For Systems above 1200Wp Solar array size min. 7
non return valve is included. or8 panels have to be wired in series.

www.Lorentz.de Rel. 070718


Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ5-8
C-SJ5-8
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance)
- 11h standard solar day
- ambient average temperature of 30°C
Head Metres /Ft.
- 1% cable loss
US 80
GPD m³/day
15/49.5

70 20/66
17500

60 25/82.5
15000

30/100
50
12500 35/115.5

40
10000

30
7500

5000 20

2500 10

Wp
300
400
500
600
700
800
900
1000
1100
2 3 4 5 6 7 8 9
1200
1300
1400
1500
1600
1700
1800
Irradiation on a tilted surface kWh/m²/day

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Internet: www.Lorentz.de
Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-8.dwg Rev. July. 2007
PS1800 C-SJ5-8 (Item No. 1162 ) for Solar Operation
(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
8
15 m / 49 ft
2000
20 m / 66 ft
7 Instantaneous Output Average Values
25 m / 82 ft 1800
30 m / 98 ft
35 m / 115 ft 1600
6

1400
5

flow rate [US gal/h]


flow rate [m³/h]

1200

4
1000

3 800

600
2
400

1
200

0 0
0 200 400 600 800 1000 1200 1400
July 07 DC power [W]

Dimensions [mm] Minimum Internal Diameter


Pump Type Weight
A B C D Emax BSP of Borehole
SJ 5A-8 525 186 339 96 98 1 1/2" 4" (104mm) 11,2 kg

System Performance Motor


An irradiation value and the required head in meters are The LORENTZ submersible motor, type EC 1200-C is a 2
given for a certain solar pumping system. pole synchronous brushless DC motor. Slide ring bearing
By connecting the point for the power output in Wp of the and ceramic trust bearings are water lubricated.
solar array with an irradiation value, move vertical The motor raw earth magnets are hermetically sealed in
upwards to the intersection with the required head curve, stainless steel and encapsulated in synthetic resin.
then horizontal to the left to find the daily quantity of The motor is pressure compensated and there are no
water that can be pumped ( m³/day) practical depth limitations for submergence.
No electronics are inside the motor and the entire motor is
Or the other way: water filled.

By starting from the daily required water amount Data:


horizontally to the intersection of the required head, then Voltage: 3 X 100V electronically commutated
vertically down to the intersection with the expected Power: 1,6kW / 2,2HP
solar irradiation, then horizontally to the left to find the Efficiency: 92% max
required output of the solar array.
Controller
Instantaneous Output Mounted at surface,
From the above curves, the maximum quantity of water Well probe and float switch terminals
in m³/h for a given solar array size in Wp and head in MPPT ( max. power point tracking)
meters / ft can be found. Add at least 25% to the DC Overload, temperature and reverse polarity protected
power to account for dirt, heat and other losses of the Pump Speed control from 30% to full
solar array. LED indicate status, pump speed water level, overload etc.
6 to 8 standard 12V modules can be connected in series.
Pump E.g. nom. Voltage 72 to 96V, max system Voltage Umax=
Centrifugal multistage direct coupled on a LORENTZ 200V
brushless submersible motor. The pump is made from
stainless steel with water lubricated rubber bearings. A
non return valve is included.

Errors excepted and possible alterations without prior notice

www.Lorentz.de Rel. 070723


Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ8-5
C-SJ8-5
Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)


- 11h standard solar day
- ambient average temperature of 30°C
US
GPD m³/day
- 1% cable loss Head Metres /Ft.
130 5 /16.5

120
30000
110
10/33
100
25000
90 15/49.5

80
20000 20/66
70

60
15000 25/82.5
50
30/100
10000
40

30

5000 20

10

Wp
300
400
500
600
700
800
900
1000
1100
2 3 4 5 6 7 8 9
1200
1300
1400
1500
1600
1700
1800
Irradiation on a tilted surface kWh/m²/day

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Internet: www.Lorentz.de
Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ8-5.dwg Rev. Sep. 2005
PS1800 C-SJ8-5 (Item No. 1164) for Solar Operation
(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
14
3500
Instantaneous Output Average Values 10 m / 33 ft

12 15 m / 49 ft
3000
20 m / 66 ft

10
25 m / 82 ft 2500
flow rate [m³/h]

flow rate [US gal/h]


8
2000

6
1500

4 1000

2 500

0 0
0 200 400 600 800 1000 1200 1400
July 07 DC power [W]

Dimensions [mm] Minimum Internal Diameter


Pump Type Weight
A B C D Emax BSP of Borehole
SJ 8A-5 601 186 415 96 98 2" 4" (104mm) 12,7 kg

System Performance Motor


An irradiation value and the required head in meters The LORENTZ submersible motor, type EC
are given for a certain solar pumping system. 1200-C is a 2 pole synchronous brushless DC
By connecting the point for the power output in Wp motor. Slide ring bearing and ceramic trust
of the solar array with an irradiation value, move bearings are water lubricated.
vertical upwards to the intersection with the required The motor raw earth magnets are hermetically
head curve, then horizontal to the left to find the sealed in stainless steel and encapsulated in
daily quantity of water that can be pumped ( m³/day) synthetic resin.
The motor is pressure compensated and there
Or the other way: are no practical depth limitations for
submergence.
By starting from the daily required water amount No electronics are inside the motor and the
horizontally to the intersection of the required head, entire motor is water filled.
then vertically down to the intersection with the
expected solar irradiation, then horizontally to the Data:
left to find the required output of the solar array. Voltage: 3 X 100V electronically commutated
Power: 1,6kW / 2,2HP
Instantaneous Output Efficiency: 92% max
From the above curves, the maximum quantity of
water in m³/h for a given solar array size in Wp and Controller
head in meters / ft can be found. Add at least 25% to Mounted at surface,
the DC power to account for dirt, heat and other Well probe and float switch terminals
losses of the solar array. MPPT ( max. power point tracking)
Overload, temperature and reverse polarity
Pump protected
Centrifugal multistage direct coupled on a LORENTZ Pump Speed control from 30% to full
brushless submersible motor. The pump is made LED indicate status, pump speed water level,
from stainless steel with water lubricated rubber overload etc.
bearings. A non return valve is included. 6 to 8 standard 12V modules can be connected
in series. E.g. nom. Voltage 72 to 96V, max
system Voltage Umax= 200V

www.Lorentz.de Rel. 070723


Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ12-3
C-SJ12-3
Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)


- 11h standard solar day
US
- ambient average temperature of 30°C
GPD m³/day - 1% cable loss Head Metres /Ft.
200 2.5/8

50000
5 /16.5
180
45000 7.5/25
160
40000
10/33
140
35000 12.5/41
120
30000 15/50
100
25000

80
20000

60
15000

10000 40

5000 20

Wp
300
400
500
600
700
800
900
1000
1100
2 3 4 5 6 7 8 9
1200
1300
1400
1500
1600
1700
1800 Irradiation on a tilted surface kWh/m²/day
BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Internet: www.Lorentz.de
Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ12-3.dwg Rev. Sep. 2005
PS1800 C-SJ12-3 (Item No. 1166) for Solar Operation
(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
22
7,5m / 25 ft
5500
20
Instantaneous Output Average Values
10 m / 33 ft
5000
18 12,5 m / 41 ft

15 m / 49 ft 4500
16
4000

14

flow rate [US gal/h]


3500
flow rate [m³/h]

12
3000

10
2500

8
2000

6 1500

4 1000

2 500

0 0
0 200 400 600 800 1000 1200 1400 1600
July 07 DC power [W]

Dimensions [mm] Minimum Internal Diameter


Pump Type Weight
A B C D Emax BSP of Borehole
SJ 12A-3 566 186 380 96 98 2" 4" (104mm) 12,5 kg

System Performance Motor


An irradiation value and the required head in meters The LORENTZ submersible motor, type EC
are given for a certain solar pumping system. 1200-C is a 2 pole synchronous brushless DC
By connecting the point for the power output in Wp motor. Slide ring bearing and ceramic trust
of the solar array with an irradiation value, move bearings are water lubricated.
vertical upwards to the intersection with the required The motor raw earth magnets are hermetically
head curve, then horizontal to the left to find the sealed in stainless steel and encapsulated in
daily quantity of water that can be pumped ( m³/day) synthetic resin.
The motor is pressure compensated and there
Or the other way: are no practical depth limitations for
submergence.
By starting from the daily required water amount No electronics are inside the motor and the
horizontally to the intersection of the required head, entire motor is water filled.
then vertically down to the intersection with the
expected solar irradiation, then horizontally to the Data:
left to find the required output of the solar array. Voltage: 3 X 100V electronically commutated
Power: 1,6kW / 2,2HP
Instantaneous Output Efficiency: 92% max
From the above curves, the maximum quantity of
water in m³/h for a given solar array size in Wp and Controller
head in meters / ft can be found. Add at least 25% to Mounted at surface,
the DC power to account for dirt, heat and other Well probe and float switch terminals
losses of the solar array. MPPT ( max. power point tracking)
Overload, temperature and reverse polarity
Pump protected
Centrifugal multistage direct coupled on a LORENTZ Pump Speed control from 30% to full
brushless submersible motor. The pump is made LED indicate status, pump speed water level,
from stainless steel with water lubricated rubber overload etc.
bearings. A non return valve is included. 6 to 8 standard 12V modules can be connected
in series. E.g. nom. Voltage 72 to 96V, max
system Voltage Umax= 200V

www.Lorentz.de Rel. 070723


Tank Height

Well to Basin
Trans. Pipe Diameter

Cable Length
Trans. Pipeline Length

Static Level
Riser Pipe Diameter
Drawdown

Pump Intake Depth

Well Diameter Depth of Well

You might also like